Loading...
HomeMy WebLinkAboutB17-0008_EL195DF Specs.pdf GAS FURNACES ELI9SDF LENNOX) ELITE°SERIES Downflow PRODUCT SPECIFICATIONS Bulletin No.210593 September 2011 Supersedes March 2011 _ _ Immo_ -------------- LENNOX I 1 ENERGY STAR AFUE - 95% Input - 44,000 to 110,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION EL195DF070P36B Unit Type 1-1 Cabinet Width EL=Elite®Series B= 17-1/2 in. C=21 in. Stages 1 =One-Stage AFUE Nominal Add-On Cooling Capacity 95=95% 36=3 tons Configuration 48=4 tons DF=Downflow 60=5 tons Nominal Gas Heat Input 045=44,000 Btuh 070=66,000 Btuh Blower 090=88,000 Btuh P=PSC Multi-Speed Blower Motor 110=110,000 Btuh 1 Indoor coils with the same letter designation will physically match the furnace. FEATURES CONTENTS Blower Data 15 Dimensions 10 ' Dimensions- Furnace/Coil Combined Dimensions 9 -- Features 2 �� I Gas Heat Accessories 7 17111 Installation Clearances 6 I l� 0 Model Number Identification 1 �l, I Ili Optional Accessories 7 I 1`I , 0 Optional Accessory Dimensions 11 ��, Specifications 6 Termination Kits Usage 9 _ 11 0 I Vent Lengths- Feet 8 r�©it-_ —; — i I ull c 1 _ , WARRANTY 1 / 4 e :� ) .,..,Ji.,,), Duralok Plus's Aluminized Steel Heat Exchanger- ;„ �/ Limited Lifetime warranty in residential applications 0 o Og �— (twenty year transferable),ten years in non-residential 1` f ;f applications. e� ° � • J 0 ,, :,•% All other covered components- Limited Five Year 111.----0--.1 (f warranty in residential applications, one year in non- I Woo - residential applications. Refer to Lennox Equipment Limited Warranty certificate HEATING SYSTEM included with equipment for details. 0 Lennox Duralok Plus- Heat Exchanger Assembly APPROVALS Units are Certified by AHRI. Lennox developed heat - exchanger assembly Units tested and rated according to US DOE test l consists of primary heat procedures and FTC labeling regulations. ' � �`,4, exchanger and Blower data from unit tests conducted in Lennox �i; � ����� secondary condenser Laboratory air test chamber. '_ coil assembly. Approved by the California Energy Commission and I'1'` + _ J Main multi-pass crimped meets California Nitrogen Oxides (NOx) Standards. . '" seam design clamshell ENERGY STAR®certified units are designed to use less -� type heat exchanger. energy, help save money on utility bills, and help protect Constructed of heavy-gauge, aluminized steel. the environment. Designed for normal expansion and contraction with ISO 9001 Registered Manufacturing Quality System. maximum efficiency and minimum resistance to air flow. APPLICATIONS 0 Secondary heat exchanger condenser coil constructed Input capacities of 44,000, 66,000, 88,000 and 110,000 of aluminum fins fitted to stainless steel tubes. Btuh. Coil is factory tested for leaks. Energy efficiency(AFUE) of 95%. Condensate drain header box assembly located on front Compact cabinet for downflow applications without any of coil. internal modifications to the unit. Compact size of complete heat exchanger assembly Lennox add-on indoor coils, high-efficiency air cleaners permits low overall design of furnace cabinet. and humidifiers can easily be added to furnace. Heat exchanger assembly has been laboratory life cycle Shipped factory assembled with controls installed and tested in excess of industry standards. wired. Lennox Designed Header Box Each unit factory test operated to ensure proper Header box on end of condenser coil collects flue operation. condensate for disposal through condensate drains. The drains are located on each side of the cabinet for easy field installation of condensate drain trap. Only one drain is used, the other drain is sealed. Condensate drain trap is included with unit for field installation. EL195DF/Page 2 FEATU RES HEATING SYSTEM (CONTINUED) OPTIONS Lennox Designed Flue Condensate Trap Assembly High Altitude Orifice Kits Condensate trap assembly is mounted outside the Required on all units for proper unit operation at conditioned air stream. altitudes from 7501 to 10,000 ft. Assembly can be mounted on either side of cabinet. Kits are available for natural gas and LPG/propane. See Installation Instructions. High Altitude Pressure Switch Kit 90° street elbow furnished for ease of drain trap Required for proper unit operation on installations above installation. 4500 ft. Drain connection can be made with field provided PVC Natural Gas to LPG/Propane Conversion Kit pipe, PVC coupling, or vinyl tubing with hose clamp. Required for field changeover from natural gas to LPG/ Drain cap on trap allows easy cleaning and winterizing. Propane. © Inshot Burners LPG/Propane to Natural Gas Conversion Kit Aluminized steel inshot burners provide efficient, Required for field changeover from LPG/Propane to trouble-free operation. natural gas. Burner venturi mixes air and gas in correct proportion DIRECT VENT/ NON-DIRECT VENT for proper combustion. 0 Furnace can be installed in either Direct Vent or Non- Burner assembly is removable from the unit as a single Direct applications. component for ease of service. In Direct Vent applications, combustion air is supplied SureLight®Hot Surface Ignitor from outdoors and flue gases are discharged outdoors. Tough, reliable, long-life, trouble-free performance. In Non-Direct Vent applications, combustion air is Silicon nitride ignitor. supplied from indoors and flue gases are discharged Cemented to steatite block for protection against current outdoors. leakage. OPTIONS Ignition leads are constructed of nickel plated copper Termination Kits and are enclosed in high temperature Teflon® insulation Facilitates installation of combustion air intake pipe and for dependable operation. flue exhaust pipe. o Gas Control Valve Refer to venting table in this bulletin to determine pipe 24 volt redundant combination gas control valve size needed and proper termination kit required. combines manual shut off switch (On-Off), automatic See Optional Accessories table and dimension electric valve (dual)and gas pressure regulation into a drawings. compact combination control. Termination Kit- Concentric - Direct Vent Flame Rollout Switches (2) Applications Manual reset switches are factory installed on burner box. 2 or 3 inch kit contains concentric termination Switch provides protection from abnormal operating assembly, reducer bushing and 45 degree elbow. conditions. 2 inch kit for-045-070 models contains an outdoor Limit Control exhaust accelerator. Automatic reset, primary limit is accurately located on Kit requires single hole penetration of roof or wall for vestibule panel on all units. installation. © Combustion Air Inducer Roof Termination Flashing Kit is available for use with Shaded pole heavy duty blower prepurges heat 2 inch Kits. exchanger and safely vents flue products. CSA certified. Operates only during heating cycle. Termination Kit- Flush-Mount Direct access allows inducer assembly to be rotated Kit contains flush-mount termination, accelerator, 90° clockwise or counterclockwise to facilitate easy vent mounting template and hardware. attachment in horizontal applications. Kit may be used with 2, 2-1/2 or 3 in. pipe. Pressure Switch Proves Combustion Air Inducer operation before allowing gas valve to open. EL195DF/Page 3 FEATURES DIRECT VENT(CONTINUED) For air-conditioning applications, blower is automatically Termination Kits -Wall Assembly energized on thermostat demand for cooling. Close Couple (US Only) - Direct Vent Applications Two accessory terminals furnished for additional power supply requirements for 120 volt(less than 1 amp) 2 or 3 inch kit consists of close-couple, side-by-side power humidifiers and powered air cleaners.A separate PVC piping with galvanized steel wall cover plate for 24V accessory terminal is also provided for low voltage sealing and isolating piping penetration of the wall. accessories. Piping spacing and length is sized for proper wall Ignition control has single red LED to indicate status installations. and as an aid in troubleshooting. CSA certified. 24 Volt Transformer Close Couple WTK (Canada Only) - Direct Vent Furnished and factory installed in control box. 40VA Applications transformer has circuit breaker wired in series. 2 or 3 inch kit contains one insulated faceplate, one Field Wiring Make-up Box insulated exhaust pipe, elbow and fittings. Furnished for line voltage wiring. Wall Ring - Direct Vent or Non-Direct Vent Applications Factory installed internally on left side of furnace. 2 inch kit contains 2 stainless steel outside seal caps, Box may be installed internally or externally on either 2 galvanized steel inside seal caps, 4 seal rings for side of furnace. the caps and 18 inch insulation sleeve for sealing and OPTIONS isolating intake and exhaust piping penetration of wall. Thermostat Maintain a maximum of 6 inches between the inlet and Thermostat(programmable/non-programmable) is not outlet openings in the installation of the pipes. furnished with unit. Roof Termination Flashing Kit- Direct Vent or Non- See Thermostat bulletins in Controls Section and Direct Vent Applications Lennox Price Book for selection. 2 or 3 inch kit contains two neoprene rubber roof Safety Night Service Kit flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Kit contains: • Also available for use with 2 inch (use 3 inch flashing) Primary limits (for each model) Concentric Vent Termination Kits used in vertical • Pressure switches (for each model) venting rooftop applications. • Flame rollout switches (for each model) 0 CONTROLS 0 BLOWER SureLight® Integrated Furnace Control Multi-speed direct drive blower. Contains all necessary controls and relays to operate Statically and dynamically balanced. furnace. Resiliently mounted. Combustion air inducer is operated by the integrated Blower assembly easily removed for servicing. furnace control. Prior to ignition, a pre-purge cycle for 15 seconds is initiated.After the main burners are Blower speeds are easily changed on the integrated turned off, a post-purge cycle for 5 seconds is run. furnace control. See blower performance tables. Flame sensor assures safe and reliable operation. Should loss of flame occur the integrated furnace control will initiate 4 re-attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Fan control consists of adjustable blower timed-off delay (60, 90, 120, 180 seconds -factory setting 90 seconds) and fixed blower timed-on delay (45 seconds). EL195DF/Page 4 FEATU RES CABINET FILTER Low-profile, narrow width cabinet allows easy OPTIONS installation in downflow applications. Downflow Filter Cabinet Heavy-gauge, cold rolled steel construction. Filter cabinet mounts directly on top of furnace. Pre-painted cabinet finish. "B and "C"width cabinets have two filters. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Filter rails are furnished. 0 Cabinet is insulated with foil faced insulation on sides Front access for servicing. and back of heating compartment and mat faced Cleanble filter(s) are furnished. insulation in blower compartment.. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. G Gas piping and electrical inlets are provided in both sides of cabinet. Coil Match-up All furnaces exactly match CR33 cased, downflow indoor coils with adaptor rails, furnished with coil. OPTIONS Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6, 24 or 50 ft. lengths. Heat Cable Tape: 66 ft. length, 1/2 in. wide fiberglass. 60 ft. length, 2 in. wide aluminum foil. Crawl Space Vent Drain Kit Allows venting through a crawl space for downflow applications. Includes 2 or 3 in. sanitary tee, 2 in. PVC assembly, PCV boot and clamp. Downflow Combustible Flooring Base Required for heating only units installed on combustible floors. Not required in add-on cooling applications. See Dimension Drawing. EL195DF/Page 5 SPECIFICATIONS Gas Model No. EL195DF045P36B EL195DF070P48B EL195DF090P60C EL195DF110P60C Heating Performance 1 AFUE 95% 95% 95% 95% Input- Btuh 44,000 66,000 88,000 110,000 Output- Btuh 42,000 64,000 85,000 106,000 Temperature rise range-°F 25-55 25-55 30-60 40-70 Gas Manifold Pressure (in.w.g.) 3.5/ 10 3.5/ 10 3.5/ 10 3.5/ 10 Nat. Gas/LPG/Propane High static-in.w.g. 0.5 0.5 0.5 0.5 Connections Intake/Exhaust Pipe(PVC) 2/2 2/2 2/2 2/2 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Condensate Drain Trap (PVC pipe)-i.d. 1/2 1/2 1/2 1/2 with furnished 90°street elbow 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt with field supplied (PVC coupling)-o.d. 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt Indoor Wheel nom. dia.x width-in. 10 x 8 11-1/2 x 10 11-1/2 x 10 11-1/2 x 10 Blower Motor output-hp 1/3 3/4 1 1 Tons of add-on cooling 2-3 3-4 4-5 4-5 Air Volume Range-cfm 605-1615 1090-1885 1270-2305 1330-2375 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.1 10.0 11.5 11.5 Maximum overcurrent protection 12 12 15 15 Shipping Data lbs. - 1 package 121 134 154 164 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES Sides 1 0 inches (0 mm) Rear 0 inches(0 mm) Top/Plenum 1 inch (25 mm) Front 0 inches(0 mm) Front(service/alcove) 24 inches(610 mm) Floor 2 Combustible NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI- Z223.1)or the National Standard of Canada CAN/CSA-B149.1 "Natural Gas and Propane Installation Code". NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ANSI-Z223.1) or applicable provisions of local building codes.In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1. 'Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed be- tween furnace and combustible floor.Not required in add-on cooling applications if instated in accordance with local codes or National Fuel Gas Code ANSI-Z223.1 or CAN/CGA-149.1,.2.Do not install the furnace directly on carpeting,tile,or other combustible materials other than wood flooring. EL195DF/Page 6 OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA "B"Width Models "C"Width Models CABINET ACCESSORIES Downflow Combustible Flooring Base 11M60 11M61 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 26K68 26K68 24 ft. 26K69 26K69 50 ft. 26K70 26K70 Heat Cable Tape Fiberglass- 1/2 in.x 66 ft. 36G53 36G53 Aluminum foil-2 in.x 60 ft. 16P89 16P89 Crawl Space Vent Drain Kit 51W18 51W18 DOWNFLOW FILTER KITS Downflow Filter Cabinet 51W07 51W08 No. and Size of filter-in. (2)20 x 20 x 1 (2)20 x 20 x 1 NIGHT SERVICE KITS Safety Night Service Kit 51W05 51W05 TERMINATION KITS See Installation Instructions for specific venting information. Termination Kits- Concentric US-2 in. 71M80 69M29 Direct Vent Applications 3 in. --- 60L46 Only Canada-2 in. 44W92 44W92 3 in. --- 44W93 Flush-Mount 2, 2-1/2 or 3 in. 51W11 51W11 Wall -Close US-2 in. 22G44 --- Couple 3 in. 44J40 44J40 Wall -Close Canada-2 in. 30G28 --- Couple WTK 3 in. 81J20 81J20 Termination Kits- Roof 2 in. 15F75 15F75 Direct or Non-Direct vent Wall Ring Kit 2 in. 15F74 3 15F74 Roof Termination Flashing Kit- Direct or Non-Direct 2 in. 44J41 44J41 Vent(2 flashings) Cleanable polyurethane frame type filter. 2 Kits contain enough parts for two,non-direct vent installations. 3 Non-direct vent only. NOTE-Termination Kits 44W92,44W93,30G28,81J20 are certified to ULC S636 standard for use in Canada only. GAS HEAT ACCESSORIES High Altitude Natural Gas to LPG/Propane Natural Gas LPG/Propane Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit High Altitude High Altitude Orifice Kit Orifice Kit 4501 -7500 ft. 7501 -10,000 ft. 0-7500 ft. 0-7500 ft. 7501-10,000 ft. 7501- 10,000 ft. 045 No Change 80W60 69W73 73W81 73W37 68W68 070 80W66 80W59 69W73 73W81 73W37 68W68 090 80W65 80W59 69W73 73W81 73W37 68W68 110 80W66 80W59 69W73 73W81 73W37 68W68 EL195DF/Page 7 VENT LENGTHS - FEET STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 045 070 090 110 045 070 090 110 1 81 66 44 24 115 115 93 58 138 137 118 118 2 76 61 39 19 110 110 88 53 133 132 113 113 3 71 56 34 14 105 105 83 48 128 127 108 108 4 66 51 29 _ N/A 100 100 78 43 123 122 103 103 No.of 5 61 46 24 N/A 95 95 73 38 118 117 98 98 90 ELL 6 56 41 19 N/A _ 90 90 68 33 113 112 93 93 7 51 36 14 N/A 85 85 63 28 108 107 88 88 8 46 31 N/A N/A 80 80 58 23 103 102 83 83 9 41 26 N/A N/A 75 75 53 18 98 97 78 78 10 36 21 N/A1 N/A 70 70 48 13 93 92 73 73 STANDARD TERMINATION ELEVATION 4501 -10,000 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 045 070 090 110 045 070 090 110 1 81 66 44 N/A 115 115 93 58 138 137 118 118 2 76 61 39 N/A 110 110 88 53 133 132 113 113 3 71 56 34 N/A 105 105 83 48 128 127 108 108 4 66 51 29 N/A 100 100 78 43 123 122 103 103 No. of 5 61 46 24 N/A 95 95 73 38 I 118 117 98 98 90 ELL 6 56 41 19 N/A 90 90 68 33 113 112 93 93 7 51 36 14 N/A 85 85 63 28 108 107 88 88 8 46 31 N/A N/A 80 80 58 23 103 102 83 83 9 41 26 N/A N/A 75 75 53 18 98 97 78 78 10 36 21 N/A N/A 70 70 48 13 93 92 73 73 CONCENTRIC TERMINATION AT ELEVATION 0-4500 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 045 070 090 110 _ 045 070 090 110 1 73 58 42 22 105 105 89 54 121 121 114 114 2 68 53 37 17 100 100 84 49 116 116 109 109 3 63 48 32 12 95 95 79 44 111 111 104 104 4 58 43 27 N/A 90 90 74 39 106 106 99 99 No. of 5 53 38 22 N/A 85 85 69 34 101 101 94 94 90 ELL 6 48 33 17 N/A 80 80 64 29 96 96 89 89 7 43 28 12 N/A 75 75 59 24 91 91 84 84 8 38 23 N/A N/A 70 70 54 19 86 86 79 79 9 33 18 N/A N/A 65 65 49 14 81 81 74 74 10 28 13 N/A N/A 60 60 44 N/A 76 76 69 69 CONCENTRIC TERMINATION ELEVATION 4501 - 10,000 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 045 070 090 110 045 070 090 110 1 73 58 42 N/A 105 105 89 54 121 121 114 114 I 2 68 53 37 N/A 100 100 84 49 116 116 109 109 3 63 48 32 N/A 95 95 79 44 111 111 104 104 4 58 43 27 N/A 90 90 74 39 106 106 99 99 No. of 5 53 38 22 N/A 85 85 69 34 101 101 94 94 90 ELL 6 48 33 17 N/A 80 80 64 29 96 96 89 89 7 43 28 12 N/A 75 75 59 24 91 91 84 84 8 38 23 N/A N/A 70 70 54 19 86 86 79 79 9 33 18 N/A N/A 65 65 49 14 81 81 74 74 10 28 13 N/A N/A 60 60 44 N/A 76 76 69 69 EL195DF/Page 8 TERMINATION KITS USAGE Concentric Terminations Standard Terminations Outdoor Exhaust Concentric Close Couple Wall Flush Accelerator Vent Pipe Kits Kits Ring Mount (Diameter X Length) Input Diameter Kit kit For use with Close Size Couple and Wall Ring Kits in. 2,2-1/2 2in. 3in. 2in. 3in. tin. or3in. 1-1/2x12 in. 2x12 in. 371M80 69M29 60L46 22G44 44J40 15F74 51W11 Field Provided 3,4 44W92 4 44W93 4 30G28 4 81J20 2 Yes --- --- Yes 1 Yes Yes Yes Yes --- 045 2-1/2 Yes --- --- Yes 1 Yes Yes Yes Yes --- 3 Yes --- --- Yes 1Yes Yes Yes Yes --- 2 Yes --- --- Yes 1Yes Yes Yes Yes --- 070 2-1/2 Yes --- --- Yes 1Yes Yes Yes Yes --- 3 Yes --- --- Yes 1 Yes Yes Yes Yes --- 2 --- Yes Yes --- Yes 2Yes Yes --- Yes 090 2-1/2 --- Yes Yes --- Yes 2Yes Yes --- Yes 3 --- Yes Yes --- Yes 2Yes Yes --- Yes 2 --- Yes Yes --- Yes 2Yes Yes --- Yes 110 2-1/2 --- Yes Yes --- Yes 2Yes Yes --- Yes 3 --- Yes Yes --- Yes 2Yes Yes --- Yes 1 Requires field provided 1-1/2 in.outdoor exhaust accelerator. 2 Requires field provided 2 in.outdoor exhaust accelerator. 3 Concentric Kits 71M80 and 44W92 include 1-1/2 in.outdoor exhaust accelerator,required when used with 045,070 input models.Accelerator is not used with 090,110, 135 input models. 4 Termination Kits 44W92,44W93,30G28,81J20 are certified to ULC S636 standard for use in Canada only. DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS Furnace Width A- _,41111 Coil Furnace Coil Overall �/ Model i 33 Width Width Height Height (838) Number • in. mm in. mm in. mm in. mm .� Overall CR33-24B-F 17-1/2 446 17-1/2 446 13-1/4 337 46-1/4 1175 Height CR33-30136B-F 17-1/2 446 17-1/2 446 16-1/8 410 49-1/8 1248 CR33-30136C-F 21 533 21 533 16-1/8 410 49-1/8 1248 0' CR33-48B-F 21 533 17-1/2 446 20 508 53 1346 n21 i; Coil CR33-48C-F 21 533 21 533 20 508 53 1346 Height IL. ���� + • CR33-50/60C-F 24-1/2 622 21 533 23-5/8 600 56-5/8 2276 0 I I ,..- 0 / . / / Coi\ Width-/ EL195DF/Page 9 DIMENSIONS - INCHES (MM) 9/16 (14) i (....> 1121 Flue Condensate Trap 1111`' Assembly COMBUSTION Furnished for external AIR INTAKE 7 AMP> 1 In field installation B RETURN AIR (178) 1 on either side of unit. EXHAUST AIR OPENING insteructions installation tionsati r OUTLET \ 1 our \ instructions for leo additional information.) + + • 2-1/16(52) I —Il2-1/4 9/16 5 (57) (14) �{ (127) TOP VIEW � A •, 1-1/2(38) , 27-3/4 . Front Panel (705) B 9/16 19-7/16f 9/16 (14) (494) (14) AIR IF FLOW .v I r A - - -- Q ELECTRICAL INLET 2(51) (Either Side) 33 Either SideG . (838) CONDENSATE GAS PIPING INLET TRAP CONNECTION (Either Side) I\ (Either Side) • O 1 9-1/8(232)Right 9(229) 6-9/16(167)Left 6-7/16(163) Either Side Either Side I T 3/4im. Supply 3/4 _li 19-1/4 Supply 3/4 (19) � C Air (19) (489) Air (19) FRONT VIEW SIDE VIEW Model No. A B C in. mm in. mm in. mm EL195DF045P36B 17-1/2 446 16-3/8 416 16 406 EL195DF070P48B EL195DF090P60C 21 533 19-7/8 505 19-1/2 495 EL195DF110P60C EL195DF/Page 10 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) DOWNFLOW FILTER CABINET "B AND"C"WIDTH FURNACES (Two Filters) 17-1/2 5 443)5)"B"Box 2C"Box 20-1/2 -\ 521) \ 17-1/2 FILTERS(2) 4N (445) 50-1/2 (1283) PPP33 (838) FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening (W x D) "B" Box 16-1/2 x 19-5/8(419 x 498) "C" Box 20 x 19-5/8 (508 x 498) DOWNFLOW COMBUSTIBLE FLOORING BASE 1-1/2 (38) SUPPLY AIR Ar- OPENING 19-13/16 21-13/16 DOWN (503) 27-1/4 (554) FLOW 1-1/2 (692) FURNACE (38) B -PP- 'le- 1-1/2 V (38) i Jr _ UltiFront Of Furnace A 1-1/2_01,1 Li_ 'I (38) 1 , . TOP VIEW SIDE VIEW r40 Cabinet Catalog A B C DOWNFLOW Width Number i COMBUSTIBLE in. mm in. mm in. mm FLOORING B 11M60 19-9/16 497 16-9/16 421 18-3/4 476 ..45._________I ' BASE C 11M61 23-1/16 586 20-1/16 510 22-1/4 565 FLOOR OPENING 22 tcgch r! EL195DF/Page 11 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) FLUSH-MOUNT VENT TERMINATION KIT(51W11) fit i o), . „p, .7N iNw \l ool ito4c q ; ,„).4. ,,,, ��I With 2 or 2-1/2 in. (51 or 64 mm)PVC pipe With 3 in. (76 mm) PVC pipe Exhaust Intake Exhaust Intake (Behind Plate) (Behind Plate) I — Seal all openings Li i Z -- N (typical) �/ N 2-3/8 (60) I I L -- — - "= // -/I // _L Air V Z / LLLL2ZZLL1 -771 Wiiiiiiii iiiiiiii ® r/////iiiii ‘,...._\. 12(305) minimum 2(51)PVC pipe (recommended) 11111 3(76)PVC pipe NOTE-PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided /_ __, 2-1/2 to 2 in. (64 to 51 mm) Coupling �— 2-1/2(64)PVC pipe IN L....--- , EL195DF/Page 12 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) CONCENTRIC WALL CONCENTRIC ROOF TERMINATION APPLICATIONS TERMINATION APPLICATIONS 4 11 1-1 FLASHING / (Not Furnished) / 12(305) Minimum OUTSIDE INTAKE Above AverageSnow .` A a' AIR EXHAUST Accumulation .�•• \ EXHAUST ► AIR n/ AIR I/►� \ ♦ M�� N "ME �� J ♦ .--411 /� r ... oir�i,� SHEET METAL STRAP `'--ice'• T 12 (305) \4 . (Clamp and sheet metal strap INTAKE CLAMP INTAKE Minimum . must be field installed to support AIR (Not Furnished) AIR Above Grade W the weight of the termination kit.) or Average Snow CLAMP Accumulation - i i r-T GRADE LA ■ 71 M80/69M29/44W92 - 2 inch kits 60L46/44W93 - 3 inch kits See Installation Instructions for additional information. Note-Field provided reducer may be A B required to adapt larger vent pipe size to termination. Cat.No. in. mm in. mm 71M80ii A ► 69M29 33-3/8 848 16-3/4 425 6-1/2, 6 44W92 29 737 15-1/2 394 (165) (152) (Canada) ♦ -- '' ,3-1/2 89)-2 in. kits iP iti r— EXHAUST 60L46 38-7/8 987 21-3/16 538 �6-- I� 4-1/2 114 -3 in. kits li�l — ♦� AIR 44W93 36-1/8 918 19-1/2 495 ---I-I-, V (Canada) j___:Jr. INTAKE AIR ELBOW TERMINATION Outdoor Exhaust Accelerator (Field Supplied) ASSEMBLY included with 71M80/44W92 (Furnished) NOTE-Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT - RING KIT 15F74- 2 inch (51 mm) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION NON-DIRECT VENT APPLICATION NOTE-EXHAUST PIPE SHOWN Kit Contains Enough Parts For Two Installations 12 in.(305 mm)-2 in.(51 mm)dia.exhaust pipe / ��� 20 in.(508 mm)-3 in.(76 mm)dia.exhaust pipe �/ maximum length without support //(// 12 in.(305 mm)-2 in.(51 mm)dia.exhaust pipe I� - ;� , l ..„ 20 in.(508 mm)-3 in.(76 mm)dia.exhaust pipe ltQ llllll`` / maximum length without /moi/ X / \ J - ^\��� - g support 11116, 6 in.(152 mm) J 8 in.(203 mm) maximum minimum NOTE-12 in.(305 mm)minimum height above NOTE-12 in.(305 mm)minimum height above average snow accumulation average snow accumulation (from bottom of vent pipe). (from bottom of vent pipe). EL195DF/Page 13 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (51 mm) 22G44 (US) 3 inch (76 mm)44J40 (US) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less thanl2 in.(305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. 8(203)MIN.Between Ends of Exhaust and Intake Pipe WALL SUPPORT 12(305)MAX.for 2(51)Dia.Exhaust 20(508)MAX.for 3(76)Dia.Exhaust 12 I/ ►I (305) 6(152) (�_1,-, ___Ii- --- EXHAUST 1� FSR 1/2(13) -il AIR k—� d`—AL-----FOAM INSULATION �Maximum 11_1r If— (Field Furnished) h T 7 INTAKE I fn 1 INTAKE I I I I AIR 1 V 1 t L.r1 EXHAUST AIR ' II 1 , I i ' AIR • Aa 1 (127)5 r 12(305)Minimum ° 12(305)Minimum I-41-8(203)MIN. 110 Grade or Average Above Grade or Average r. Snow Accumulation 5-1/2 Snow Accumulation if. GRADE )9) GRADE 12(305)MAX.for 2(51)Dia.Exhaust T 20(508)MAX.for 3(76)Dia.Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (51 mm) 30G28 (WTK Canada) 3 inch (76 mm) 81J20 (WTK Canada) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less thanl2 in.(305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT \12(305)MAX.for 2(51)Dia.Exhaust 20(508)MAX.for 3(76)IIDia.Exhaust I° ►i 12 (305) �I 6(152) (� ii___--- EXHAUST / 1/2(13) _� II AIR kk_1I a.` �FOAM INSULATION Maximum I � 'I 6(152)4.4�� Ir _ (Field Furnished) 7�4I MIN. INTAKE 1 1 I I i 1 AIR I�I t F� EXHAUST INTAKE ' , i / AIR i AIR ; ; I (127) I .± 12(305)Minimum ° '�' 4�6(152)MIN. 12(305)Minimum pi Above Grade or Average 5-1/2 Above Grade or Average ► Snow Accumulation (140) Snow Accumulation ' ir , GRADE r GRADE 12(305)MAX.for 2(51)Dia.Exhaust I I 20(508)MAX.for 3(76)Dia.Exhaust EL195DF/Page 14 BLOWER DATA EL195DF045P36B PERFORMANCE(Less Filter) EL195DF090P60C PERFORMANCE (Less Filter) External Air Volume/Watts at Various Blower Speeds External Air Volume/Watts at Various Blower Speeds Static Medium- Medium- Static Medium- Medium- HighPressure High Low Low Pressure High High Low Low in.w'g' cfm Watts cfm Watts cfm Watts cfm Watts in.w'g' cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1615 650 1385 555 1205 465 1045 390 0.00 2305 1255 2145 950 1900 810 1515 670 0.10 1605 640 1380 545 1195 455 1035 380 0.10 2295 1240 2135 940 1885 795 1500 665 0.20 1500 620 1345 525 1165 445 1015 370 0.20 2200 1220 2085 915 1865 775 1525 655 0.30 1450 590 1290 490 1125 420 975 365 0.30 2160 1210 1990 875 1830 755 1545 640 0.40 1350 560 1235 480 1090 405 920 345 0.40 2055 1170 1935 865 1790 725 1530 620 0.50 1300 545 1170 450 1035 380 880 330 0.50 1970 1130 1855 835 1705 700 1500 600 0.60 1195 500 1095 425 990 365 840 320 0.60 1890 1105 1765 805 1635 675 '1495 580 0.70 1140 480 1020 395 895 345 780 300 0.70 1775 1075 1680 785 1565 655 1430 560 0.80 1025 450 920 370 840 330 695 270 0.80 1690 1050 1590 760 1485 630 1370 540 0.90 945 430 800 335 700 290 605 250 0.90 1580 1010 1485 735 1405 610 1270 510 ELI95DF070P48B PERFORMANCE(Less Filter) ELI95DF110P60C PERFORMANCE (Less Filter) Air Volume/Watts at Various Blower Speeds Air Volume/Watts at Various Blower Speeds External External Static Medium- Medium- Static Medium- Medium- HighPressure High Low LOW Pressure High High Low Low in.w'g' cfm Watts cfm Watts cfm Watts cfm Watts in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1885 935 1830 815 1810 720 1700 640 0.00 2375 1250 2205 915 1975 785 1630 640 0.10 1850 910 1805 795 1785 705 1680 630 0.10 2365 1235 2195 905 1960 775 1625 635 0.20 1775 I 890 1750 775 1710 690 1620 610 0.20 2275 1200 2125 890 1950 760 1635 625 0.30 1715 870 1685 755 1640 660 1575 595 0.30 2200 1180 2060 880 1900 735 1620 610 0.40 1645 855 1620 735 1595 650 1495 575 0.40 2115 1150 1995 850 1845 710 1620 600 0.50 1575 835 1525 715 1485 625 1440 555 0.50 2040 1115 1940 835 1795 695 1585 580 0.60 1505 815 1450 690 1425 610 1360 540 0.60 1955 1090 1855 810 1745 670 1540 565 0.70 1390 790 1360 675 1340 590 1270 525 0.70 1860 1070 1730 765 1640 650 1515 550 0.80 1280 770 1270 650 1255 570 1210 505 0.80 1735 1030 1620 740 1590 620 1415 535 0.90 1200 740 1185 635 1160 550 1090 485 0.90 1640 1010 1535 715 1480 600 1330 510 EL195DF/Page 15 REVISIONS Sections Description of Change Optional Accessories Removed Night Service Kit. DESIGN "�,�' A uI C 1 P 0 t.! 10 I 0 I Vui Nos CERTIFIEDTM ® ® 446* •Il� r C www.ahridirectory.org © CERTIFIED / REGISTERED ,/MEMOfR COMPANY0 j CERTIFIED QUALITY ® — ® SYSTEMS Visit us at www.lennox.com J For the latest technical information,www.lennoxdavenet.com Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2011 Lennox Industries,Inc.