HomeMy WebLinkAboutB17-0008_EL195UH Specs.pdf GAS FURNACES EL195U H LENNOX) ELITE°SERIES ® Upflow / Horizontal PRODUCT SPECIFICATIONS Bulletin No.210592 March 2011 Supersedes January 2011 (.......-42 --- LEN/0- 1 • 0 II a --",mIIIIIIIIN; Jr ENERGY STAR AFUE - 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons MODEL NUMBER IDENTIFICATION EL 195 UH 070 P 36 B Unit Type L__,Cabinet Width EL=Elite®Series B= 17-1/2 in. C=21 in. Stages D=24-1/2 in. 1 =One-Stage AFUE Nominal Add-On Cooling Capacity 95=95% 24=2tons Configuration 36=3 tons UH=Upflow/Horizontal 48=4 tons 60=5 tons Nominal Gas Heat Input 045=44,000 Btuh Blower 070=66,000 Btuh P=PSC Multi-Speed Blower Motor 090=88,000 Btuh 110=110,000 Btuh 135= 132,000 Btuh 1 Indoor coils with the same letter designation will physically match the furnace. FEATU RES m 0, , . „ CONTENTS -411111L-maBlower Data 19 ,sigi or 4�© Dimensions- Furnace/Coil Combined Dimensions . . 15 1' 1i p(4I © �,0 Dimensions - Horizontal Position 13 �—�i „Ail i Dimensions - Upflow Position 12 �; �© 111 1` — � — . duo Features 2 //� � .-- - �. 11r0f�r Gas Heat Accessories 901-44P- A*1- Fol,„' Installation Clearances 8 � k� •%�,,�,�r �� Model Number Identification 1 �� „ fii 12 Optional Accessories 9 _si 41 . Optional Accessory Dimensions 14 ° A , Specifications 7 r ' '• • Termination Kits Usage 11 ill, =` g Vent Lengths- Feet 10 1 1111 • i Im II 144,1 , it\ii.,irAllik r ...._. 01„._..... \Iiiimmaal ll WARRANTY APPLICATIONS Duralok Plus-Aluminized Steel Heat Exchanger- Input capacities of 44,000, 66,000, 88,000, 110,000 and Limited Lifetime warranty in residential applications 132,000 Btuh. (twenty year transferable),ten years in non-residential Energy efficiency (AFUE) of 95%. applications. Compact cabinet for upflow, horizontal-left or horizontal- All other covered components - Limited Five Year right applications without any modifications. warranty in residential applications, one year in non- residential applications. Removable bottom seal panel shipped in place for side return air is easily removed for bottom/end return air Refer to Lennox Equipment Limited Warranty certificate applications. included with equipment for details. Utility room, alcove, closet, crawl space, basement or APPROVALS attic installation. Units are Certified by AHRI. Lennox add-on indoor coils, high-efficiency air cleaners Units tested and rated according to US DOE test and humidifiers can easily be added to furnace. procedures and FTC labeling regulations. Shipped factory assembled with all controls installed Blower data from unit tests conducted in Lennox and wired. Laboratory air test chamber. Each unit factory test operated to ensure proper Approved by the California Energy Commission and operation. meets California Nitrogen Oxides (NOx) Standards. ENERGY STAR°certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 9001 Registered Manufacturing Quality System. ELI95UH/Page 2 FEATURES HEATING SYSTEM 0 SureLight®Hot Surface Ignitor 0 Lennox Duralok Plus- Heat Exchanger Assembly Tough, reliable, long-life, trouble-free performance. Lennox developed heat exchanger assembly consists Silicon nitride ignitor. , , of primary heat exchanger Cemented to steatite block for protection against current , i and secondary condenser leakage. A& -_- coil assembly. Ignition leads are constructed of nickel plated copper t Main multi-pass crimped and are enclosed in high temperature Teflon°insulation _ 1 seam design clamshell for dependable operation. type heat exchanger. --]T �, 0 Gas Control Valve Constructed of heavy- 24i , gauge, aluminized steel. volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic I Designed for normal g electric valve (dual) and gas pressure regulation into a `" expansion and contraction p compact combination control. with maximum efficiency and minimum resistance to air flow. 0 Combustion Air Inducer 0 Secondary heat exchanger condenser coil constructed Shaded pole heavy duty blower prepurges heat of aluminum fins fitted to stainless steel tubes. exchanger and safely vents flue products. Coil is factory tested for leaks. Operates only during heating cycle. Condensate drain header box assembly located on front Pressure Switch of coil. Proves Combustion Air Inducer operation before Compact size of complete heat exchanger assembly allowing gas valve to open. permits low overall design of furnace cabinet. 0 Flame Rollout Switches (2) Heat exchanger assembly has been laboratory life cycle Manual reset switches are factory installed on burner box. tested in excess of industry standards. Switch provides protection from abnormal operating Lennox Designed Header Box conditions. Header box on end of condenser coil collects flue Limit Control condensate for disposal through condensate drains. Automatic reset, primary limit is accurately located on The drains are located on each side of the cabinet for vestibule panel on all units. easy field installation of condensate drain trap. OPTIONS Only one drain is used, the other drain is sealed. High Altitude Orifice Kits Condensate drain trap is included with the unit for field Required on all units for proper unit operation at installation. altitudes from 7501 to 10,000 ft. Lennox Designed Flue Condensate Trap Assembly Kits are available for natural gas and LPG/propane. Condensate trap assembly is mounted outside the conditioned air stream. High Altitude Pressure Switch Kit Assembly can be mounted on either side of cabinet in Required for proper unit operation on installations above upflow applications.Assembly is mounted below the 4500 ft. cabinet in horizontal applications. Can also be mounted Natural Gas to LPG/Propane Conversion Kit remotely (up to 5 ft. away)from unit. See Installation Required for field changeover from natural gas to LPG/ Instructions. Propane. 90° street elbow furnished for ease of drain trap LPG/Propane to Natural Gas Conversion Kit installation. Required for field changeover from LPG/Propane to Drain connection can be made with field provided PVC natural gas. pipe, PVC coupling, or vinyl tubing with hose clamp. Drain cap on trap allows easy cleaning and winterizing. 0 Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. EL195UH/Page 3 FEATU RES DIRECT VENT/ NON-DIRECT VENT Wall Ring - Direct Vent or Non-Direct Vent Furnace can be installed in either Direct Vent or Non- Applications Direct applications. 2 inch kit contains 2 stainless steel outside seal caps, In Direct Vent applications, combustion air is supplied 2 galvanized steel inside seal caps, 4 seal rings for from outdoors and flue gases are discharged outdoors. the caps and 18 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged Maintain a maximum of 6 inches between the inlet and outdoors. outlet openings in the installation of the pipes. Roof Termination Flashing Kit OPTIONS Termination Kits 2 or 3 inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Facilitates installation of combustion air intake pipe and Vent pipe and insulation not furnished. flue exhaust pipe. Refer to venting table in this bulletin to determine pipe Also available for use with 2 inch (use 3 inch flashing) size needed and proper termination kit required. Concentric Vent Termination Kits used in vertical venting rooftop applications. See Optional Accessories table and dimension drawings. 0 CONTROLS Termination Kit- Concentric- Direct Vent SureLight®Integrated Furnace Control Applications Contains all necessary controls and relays to operate 2 or 3 inch kit contains concentric termination furnace. assembly, reducer bushing and 45 degree elbow. Combustion air inducer is operated by the integrated 2 inch kit for-045-070 models contains an outdoor furnace control. Prior to ignition, a pre-purge cycle exhaust accelerator. for 15 seconds is initiated.After the main burners are Kit requires single hole penetration of roof or wall for turned off, a post-purge cycle for 5 seconds is run. installation. Flame sensor assures safe and reliable operation. Roof Termination Flashing Kit is available for use with Should loss of flame occur the integrated furnace 2 inch Kits. control will initiate 4 re-attempts at ignition before CSA certified. locking out unit operation for 60 minutes. Termination Kit- Flush-Mount Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand Kit contains flush-mount termination, accelerator, after unit lockout, eliminating nuisance calls for service. mounting template and hardware. Fan control consists of adjustable blower timed-off delay Kit may be used with 2, 2-1/2 or 3 in. pipe. (60, 90, 120, 180 seconds -factory setting 90 seconds) Termination Kits -Wall Assembly and fixed blower timed-on delay (30 seconds heating, 2 Close Couple (US Only) - Direct Vent Applications seconds cooling). 2 or 3 inch kit consists of close-couple, side-by-side For air-conditioning applications, blower is automatically PVC piping with galvanized steel wall cover plate for energized on thermostat demand for cooling. sealing and isolating piping penetration of the wall. Two accessory terminals furnished for additional power Piping spacing and length is sized for proper wall supply requirements for 120 volt(less than 1 amp) installations. power humidifiers and powered air cleaners.A separate 24V accessory terminal is also provided for low voltage CSA certified. accessories. Close Couple WTK (Canada Only) - Direct Vent Ignition control has single red LED to indicate status Applications and as an aid in troubleshooting. 2 or 3 inch kit contains one insulated faceplate, one 24 Volt Transformer insulated exhaust pipe, elbow and fittings. Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. ELI95UH/Page 4 FEATURES OPTIONS CABINET Thermostat Low-profile, narrow width cabinet allows easy Thermostat (programmable/non-programmable) is not installation in upflow or horizontal applications. furnished with unit. Heavy-gauge, cold rolled steel construction. See Thermostat bulletins in Controls Section and Pre-painted cabinet finish. Lennox Price Book for selection. Flanges provided on supply air opening for ease of Safety Night Service Kit plenum connection or alignment with indoor coil. Kit contains: Q Fully insulated cabinet with foil faced insulation on • Primary limits (for each model) sides and back of heating compartment and mat faced • Pressure switches (for each model) insulation in blower compartment. • Flame rollout switches (for each model) Sealed blower compartment. Inner blower compartment access panel seals blower BLOWER compartment from air leakage. 0 Multi-speed direct drive blower. Q Tool-less latches on blower and burner doors assure Statically and dynamically balanced. positive lock. Resiliently mounted. Complete service access. Blower assembly easily removed for servicing. Safety interlock switch automatically shuts off power to Blower speeds are easily changed on the integrated unit when blower compartment access door is removed. furnace control. See blower performance tables. ® Gas piping and electrical inlets are provided in both sides of cabinet. Return Air Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. See dimension drawings. NOTE -60C and 60D size units that require air volumes over 1800 cfm must have one of the following: 1. Single side return air with transition, to accommodate 20 x 25 x 1 in. cleanable air filter. Required to maintain proper air velocity. 2. Single side return air with Optional Return Air Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. Coil Match-up All furnaces exactly match C33 and CX34 cased upflow indoor coils and CH33 horizontal indoor coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. EL195UH/Page 5 FEATU RES OPTIONS FILTER(NOT FURNISHED) Condensate Drain Heat Cable Kits Filter and provisions for external mounting must be field Self-limiting wattage heat cable prevents condensate provided. drain from freezing in unconditioned areas. OPTIONS Available in 6, 24 or 50 ft. lengths. Air Filter and Rack Kit for Horizontal Return Air Heat Cable Tape: (End)Applications 66 ft. length, 1/2 in. wide fiberglass. Washable or vacuum cleanable polyurethane frame 60 ft. length, 2 in. wide aluminum foil. type filter and external end return air rack available for field installation. Horizontal Suspension Kit Rack has filter door for easy filter servicing. Provides suspension of unit and coil in horizontal Flanges on rack allow easy duct connection. applications. Allows complete service access. See dimension drawing. Consists of corner mounted hanging brackets with Air Filter and Rack Kit for Upflow Side Return Air vibration isolators, return air end support rail and Applications - Not for use with Return Air Base hardware for assembly. Washable or vacuum cleanable polyurethane frame Metal hanging straps must be field provided. type filter and external side return air rack available for Crawl Space Vent Drain Kit field installation. Allows venting through a crawl space for upflow and Available in single and ten pack kits. horizontal applications. Rack has filter door for easy filter servicing. Includes 2 or 3 in. sanitary tee, 2 in. PVC assembly, Flanges on rack allow easy duct connection. PCV boot and clamp. Field installs on either side of unit cabinet. See Return Air Base dimension drawing. On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or Return Air Base is required when using an IAQ product higher than 14-3/16 in. installed next to the unit and serviced from the front. IAQ products higher than 20 in. require a field fabricated transition. Must be used for 60C and 60D models with air volumes over 1800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. See Dimension Drawing. ELI95UH/Page 6 SPECIFICATIONS Gas Model No. EL195UH045P24B EL195UH045P36B EL195UH070P36B EL195UH070P48B Heating 1 AFUE 95% 95% 95% 95% Performance Input- Btuh 44,000 44,000 66,000 66,000 Output-Btuh 42,000 42,000 64,000 64,000 Temperature rise range-°F 40-70 25-55 40-70 25-55 Gas Manifold Pressure(in.w.g.) 3.5/10 3.5/10 3.5/ 10 3.5/10 Nat. Gas/LPG/Propane High static-in.w.g. 0.5 0.5 0.5 0.5 Connections Intake/Exhaust Pipe(PVC) 2/2 2/2 2/2 2/2 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Condensate Drain Trap(PVC pipe)-i.d. 1/2 1/2 1/2 1/2 with furnished 90°street elbow 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt with field supplied (PVC coupling)-o.d. 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt Indoor Wheel nom. dia.x width-in. 10 x 8 10 x 8 10 x 8 11-1/2 x 10 Blower Motor output-hp 1/5 1/3 1/3 3/4 Tons of add-on cooling 2-2.5 2-3 2-3 3-4 Air Volume Range-cfm 390-1140 700-1605 650-1585 1145-2015 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 3.1 6.1 6.1 10.0 Maximum overcurrent protection 12 12 12 12 Shipping Data lbs.- 1 package 119 121 129 134 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. SPECIFICATIONS Gas Model No. ELI95UH090P36C ELI95UH090P48C ELI95UH090P60C ELI95UH110P48C Heating 'AFUE 95% 95% 95% 95% Performance - Input- Btuh 88,000 88,000 88,000 110,000 Output- Btuh 85,000 85,000 85,000 105,000 Temperature rise range- °F 50-80 40-70 30-60 50-80 Gas Manifold Pressure (in.w.g.) 3.5/ 10 3.5/10 3.5/10 3.5/10 Nat. Gas/LPG/Propane High static-in.w.g. 0.5 0.5 0.5 0.5 Connections Intake/Exhaust Pipe(PVC) 2/2 2/2 2/2 2/2 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Condensate Drain Trap(PVC pipe)-i.d. 1/2 1/2 1/2 1/2 with furnished 90°street elbow 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt with field supplied (PVC coupling)-o.d. 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt Indoor Wheel nom. dia.x width-in. 10 x 8 10 x 10 11-1/2 x 11 10 x 10 Blower Motor output-hp 1/3 1/2 1 1/2 Tons of add-on cooling 2-3 3-4 4-5 3-4 Air Volume Range-cfm 655-1630 900-2140 1290-2445 715-2000 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.1 8.2 11.5 8.2 Maximum overcurrent protection 12 12 12 12 Shipping Data lbs.- 1 package 144 149 154 159 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. EL195UH/Page 7 SPECIFICATIONS Gas Model No. ELI95UH110P60C ELI95UH135P60D Heating 1 AFUE 95% 95% Performance Input-Btuh 110,000 132,000 Output-Btuh 106,000 126,000 Temperature rise range-°F 40-70 45-75 Gas Manifold Pressure(in. w.g.) 3.5/10 3.5/10 Nat. Gas/LPG/Propane High static-in.w.g. 0.5 0.5 Connections Intake/Exhaust Pipe(PVC) 2/2 2/2 in. Gas pipe size IPS 1/2 1/2 Condensate Drain Trap(PVC pipe)-i.d. 1/2 1/2 with furnished 90°street elbow 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt with field supplied(PVC coupling)-o.d. 1/2 slip x 1/2 Npt 1/2 slip x 1/2 Npt Indoor Wheel nom.dia.x width-in. 11-1/2 x 10 11-1/2 x 10 Blower Motor output-hp 1 1 Tons of add-on cooling 4-5 4-5 Air Volume Range-cfm 1235-2485 1135-2595 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 11.5 11.5 Maximum overcurrent protection 15 15 Shipping Data lbs. - 1 package 164 177 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES - INCHES (MM) Sides 1 0 inches(0 mm) Rear 0 inches(0 mm) Top/Plenum 1 inch (25 mm) Front 0 inches(0 mm) Front(service/alcove) 24 inches(610 mm) Floor 2 Combustible NOTE-Air for combustion must conform to the methods outlined in the National Fuel Gas Code(NFPA 54/ANSI-Z223.1) or the National Standard of Canada CAN/CSA-B149.1 Natural Gas and Propane Installation Code". NOTE-In the U.S.flue sizing must conform to the methods outlined in the current National Fuel Gas Code(NFPA 54/ ANSI-Z223.1)or applicable provisions of local building codes.In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B149.1. 'Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Do not install the furnace directly on carpeting,tile,or other combustible materials other than wood flooring. EL195UH/Page 8 OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA "B"Width "C"Width "D"Width Models Models Models CABINET ACCESSORIES Horizontal Suspension Kit-Horizontal only 51W10 51W10 51W10 Return Air Base-Upflow only 50W98 50W99 51W00 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 26K68 26K68 26K68 24 ft. 26K69 26K69 26K69 50 ft. 26K70 26K70 26K70 Heat Cable Tape Fiberglass- 1/2 in.x 66 ft. 36G53 36G53 36G53 Aluminum foil -2 in.x 60 ft. 16P89 16P89 16P89 Crawl Space Vent Drain Kit 51W18 51W18 51W18 FILTER KITS 'Air Filter and Horizontal (end) Size of filter-in. 87L96- 18 x 25 x 1 87L97-20 x 25 x 1 87L98-25 x 25 x 1 Rack Kit Side Return Single 44J22 44J22 44J22 Ten Pack 66K63 66K63 66K63 Size of filter-in. 16x25x 1 16x25x 1 16x25x 1 NIGHT SERVICE KIT Safety Night Service Kit 51W05 51W05 51W05 TERMINATION KITS See Installation Instructions for specific venting information. Termination Kits- Concentric US-2 in. 71M80 69M29 --- Direct Vent 3 in. --- 60L46 60L46 Applications Only Canada-2 in. 44W92 44W92 --- 3 in. --- 44W93 44W93 Flush-Mount 2, 2-1/2 or 3 in. 51W11 51W11 51W11 Wall -Close US-2 in. 22G44 --- --- Couple 3 in. 44J40 44J40 44J40 Wall -Close Canada-2 in. 30G28 --- --- Couple WTK 3 in. 81J20 81J20 81J20 Termination Kits- Roof 2 in. 15F75 15F75 --- Direct or Non- Wall Ring Kit 2 in. 15F74 315F74 --- Direct vent Roof Termination Flashing Kit-Direct or 2 in. 44J41 44J41 44J41 Non-Direct Vent(2 flashings) I Cleanable polyurethane frame type filter. 2 Kits contain enough parts for two,non-direct vent installations. 3 Non-direct vent only. NOTE-Termination Kits 44W92,44W93,30G28,81J20 are certified to ULC S636 standard for use in Canada only. GAS HEAT ACCESSORIES High Altitude Natural Gas to LPG/Propane Natural Gas LPG/Propane Input Pressure Switch Kit LPG/Propane Kit to Natural Gas Kit High Altitude High Altitude Orifice Kit Orifice Kit 4501 -7500 ft. 7501 - 10,000 ft. 0-7500 ft. 0-7500 ft. 7501- 10,000 ft. 7501-10,000 ft. 045 No Change 80W60 69W73 73W81 73W37 68W68 070 80W66 80W59 69W73 73W81 73W37 68W68 090 80W65 80W59 69W73 73W81 73W37 68W68 110 80W66 80W59 69W73 73W81 73W37 68W68 135 80W65 80W59 69W73 73W81 73W37 68W68 EL195UH/Page 9 VENT LENGTHS - FEET STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 81 66 44 24 N/A 115 115 93 58 N/A 138 137 118 118 89 2 76 61 39 19 N/A 110 110 88 53 N/A 133 132 113 113 84 3 71 56 34 14 N/A 105 105 83 48 N/A 128 127 108 108 79 4 66 51 29 N/A N/A 100 100 78 43 N/A 123 122 103 103 74 No.of 5 61 46 24 N/A N/A 95 95 73 38 N/A 118 117 98 98 69 90 ELL 6 56 41 19 N/A N/A 90 90 68 33 N/A 113 112 93 93 64 7 51 36 14 N/A N/A 85 85 63 28 N/A 108 107 88 88 59 8 46 31 N/A N/A N/A 80 80 58 23 N/A 103 102 83 83 54 9 41 26 N/A N/A N/A 75 75 53 18 N/A 98 97 78 78 49 10 36 21 N/A N/A N/A 70 70 48 13 N/A 93 92 73 73 44 STANDARD TERMINATION ELEVATION 4501 - 10,000 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 81 66 44 N/A N/A 115 115 93 58 N/A 138 137 118 118 89 2 76 61 39 N/A N/A 110 110 88 53 N/A 133 132 113 113 84 3 71 56 34 N/A N/A 105 105 83 48 N/A 128 127 108 108 79 4 66 51 29 N/A N/A 100 100 78 43 N/A 123 122 103 103 74 No. of 5 61 46 24 N/A N/A 95 95 73 38 N/A 118 117 98 98 69 90 ELL 6 56 41 19 N/A N/A 90 90 68 33 N/A 113 112 93 93 64 7 51 36 14 N/A N/A 85 85 63 28 N/A 108 107 88 88 59 8 46 31 N/A N/A N/A 80 80 58 23 N/A 103 102 83 83 54 9 41 26 N/A N/A N/A 75 75 53 18 N/A 98 97 78 78 49 10 36 21 N/A N/A N/A 70 70 48 13 N/A 93 92 73 73 44 CONCENTRIC TERMINATION AT ELEVATION 0-4500 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 73 58 42 22 N/A 105 105 89 54 N/A 121 121 114 114 80 2 68 53 37 17 N/A 100 100 84 49 N/A 116 116 109 109 75 3 63 48 32 12 N/A 95 95 79 44 N/A 111 111 104 104 70 4 58 43 27 N/A N/A 90 90 74 39 N/A 106 106 99 99 65 No. of 5 53 38 22 N/A N/A 85 85 69 34 N/A 101 101 94 94 60 90 ELL 6 48 33 17 N/A N/A 80 80 64 29 N/A 96 96 89 89 55 7 43 28 12 N/A N/A_ 75 75 59 24 N/A 91 91 84 84 50 8 38 23 N/A N/A N/A 70 70 54 19 N/A 86 86 79 79 45 9 33 18 N/A N/A N/A 65 65 49 14 N/A 81 81 74 74 40 10 28 13 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 35 CONCENTRIC TERMINATION ELEVATION 4501 - 10,000 ft. Pipe Size 2 in. 2-1/2 in. 3 in. Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 73 58 42 N/A N/A 105 105 89 54 N/A 121 121 114 114 80 2 68 53 37 N/A N/A 100 100 84 49 N/A 116 116 109 109 75 3 63 48 32 N/A N/A 95 95 79 44 N/A 111 111 104 104 70 4 58 43 27 N/A N/A 90 90 74 39 N/A 106 106 99 99 65 No. of _ 5 53 38 22 N/A N/A 85 85 69 34 N/A 101 101 94 94 60 90 ELL 6 48 33 17 N/A N/A 80 80 64 29 N/A 96 96 89 89 55 7 43 28 12 N/A N/A 75 75 59 24 N/A 91 91 84 84 50 8 38 23 N/A N/A N/A 70 70 54 19 N/A 86 86 79 79 45 9 33 18 N/A N/A N/A 65 65 49 14 N/A 81 81 74 74 40 10 28 13 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 35 EL195UH/Page 10 TERMINATION KITS USAGE Concentric Terminations Standard Terminations Outdoor Exhaust Concentric Close Couple Wall Flush Accelerator Vent Pipe Kits Kits Ring Mount (Diameter X Length) Input Diameter Kit kit For use with Close Size Couple and Wall Ring Kits in. 2,2-1/2 2in. 3in. 2in. 3in. tin. or3in. 1-1/2x12 in. 2x12 in. 371M80 69M29 60L46 22G44 44J40 15F74 51W11 Field Provided 3'4 44W92 4 44W93 4 30G28 4 81J20 2 Yes --- --- Yes 1 Yes Yes Yes Yes --- 045 2-1/2 Yes --- --- Yes 1 Yes Yes Yes Yes --- 3 Yes --- --- Yes 'Yes Yes Yes Yes --- 2 Yes --- --- Yes 'Yes Yes Yes Yes --- 070 2-1/2 Yes --- --- Yes 1Yes Yes Yes Yes --- 3 Yes --- --- Yes 'Yes Yes Yes Yes --- 2 --- Yes Yes --- Yes 2Yes Yes --- Yes 090 2-1/2 --- Yes Yes --- Yes 2Yes Yes --- Yes 3 --- Yes Yes --- Yes 2Yes Yes --- Yes 2 --- Yes Yes --- Yes 2Yes Yes --- Yes 110 2-1/2 --- Yes Yes --- Yes 2Yes Yes --- Yes 3 --- Yes Yes --- Yes 2 Yes Yes --- _ Yes 135 3 --- --- Yes --- --- --- Yes --- I Yes 'Requires field provided 1-1/2 in.outdoor exhaust accelerator. 2 Requires field provided 2 in.outdoor exhaust accelerator. 'Concentric Kits 71M80 and 44W92 include 1-1/2 in.outdoor exhaust accelerator,required when used with 045,070 input models.Accelerator is not used with 090,110, 135 input models. 4 Termination Kits 44W92,44W93,30G28,81J20 are certified to ULC S636 standard for use in Canada only. EL195UH/Page 11 DIMENSIONS - INCHES (MM) - UPFLOW POSITION 1 NOTE-60C and 60D size units that require air volumes over 1800 cfm must have one of the following: 1.Single side return air with transition,to accommodate 20 x 25 x 1 in.cleanable air filter. EXHAUST AIR 3-1/4 Required to maintain proper air velocity. ��(83) OUTLET 2.Single side return air with Optional Return Air Base 3. Bottom return air. a� 4. Return air from both sides. + 5. Bottom and one side return air. See Blower Performance Tables for additional information. D 2 Optional Side Return Air Filter Kit is not for use ill with the Optional Return Air Base. I SUPPLY OPE I GR i Ho... Flue Condensate Trap COMBUSTION �'� Assembly AIR INTAKE Furnished for external _ 7 (41..>I Iirm l0 2 field installation OPTIONAL I (178) 1 on either side of unit. SIDE RETURN _ 23-3/4 (See installation AIR FILTER KIT (603) ��• instructions for (Either Side) (635) P13additional information.) TOP VIEW 1 ~ -41 1-1/2(38) 27-3/4 A Front Panel (705) B -9/16(14) 19-7/16 )6-1.- x9/16 04) 1 I I I V 4 1f LENNOX 6-9/16(167) 2(51) Left (Either Side) 9(229) z OPTIONAL Right GAS PIPING INLET SIDE RETURN 12-5/8(321) + + (Either Side) AIR FILTER KIT (Either Side) CONDENSATE (Either Side) 33 i STRAP CONNECTION CI + (Either Side) ./ (838) ► 6-1/2(165) ELECTRICAL 01 (Either Side) 1 / INLET O (Either Side) 23 f1-1/2 14-3/4 141 (584) (38) (375) 1 Side Return 14 16 Air Opening (356) (406) (Either Side) I AIR FLOW I_I) V 1 - 1-15/16(49) t_5/8 3/4_rn„,i _ .....i_3/4 (16) 3-1/4 23-1/2 (19) C (19) (83) (597) II 1 Bottom Return 1 Bottom Return Air Opening Air Opening FRONT VIEW SIDE VIEW A B C D Model No. in. mm in. mm in. mm in. mm EL195UH045P24B EL195UH045P36B 17-1/2 446 16-3/8 416 16 406 7-5/8 194 EL195UH070P36B EL195UH070P48B EL195UH090P36C EL195UH090P48C EL195UH090P60C 21 533 19-7/8 505 19-1/2 495 9-3/8 238 EL195UH110P48C ELI 95UH110P60C EL195UH135P6OD 24-1/2 622 23-3/8 594 23 584 9-3/4 248 EL195UH/Page 12 DIMENSIONS - INCHES (MM) - HORIZONTAL POSITION LEFT-HAND AIR DISCHARGE r 1 • CONDENSATE 12-5/8(321) TRAP CONNECTION (Bottom) Bottom AIR 6-9/16(167)Top FLOW T 9(229)Bottom �� (TopELECor BottomRICAL INLET) a/ Im 6-1/2(165) , Bottom /1 ` Q+ o L2(51)' TOP VIEW GAS PIPING INLET Top or Bottom (Top or Bottom) 27-3/4 33 1-1/2(38) 27-3/4 (705) 9/1g► COMBUSTION 838 Front Panel ~AIR INTAKE (838) 3/4 (705) x(14) (19) 1 ' i 9/16 19-7/16 )/"' i 3-1/4 :� 23-1/2 (14) ~(494) I e A . AIR (95) I (591) SUPPLY B �Il A r FLOW A C RETURN AIR II D I AIR OPENING + [f I/ 1 1 OPENING EXHAUST AIR/ ko-t-1-7/8(48) OUTLET 3-1/4(83) FRONT VIEW END VIEW END VIEW RIGHT-HAND AIR DISCHARGE r CONDENSATE TRAP CONNECTION (Bottom) AIR 12-5/8(321) FLOW 4 I Bottom 6-1/2(165) 9(229)Top Bottom 6-9/16(167)Bottom Jo tt +I. 2(51) N —f-Top or Bottom ELECTRICAL INLET GAS PIPING INLET (Top or Bottom) TOP VIEW (Top or Bottom) EXHAUST AIR 27-3/4 1-1/2(38) 33 OUTLET 27-3/4 (705)—wv Front Panel (838) 1-7/8 3-1/4 (705) (48)�\ (83) 23-1/2 C 3-1/4 I I - . 19-7/16 (591) (95) AIR II D "4—(494) 9/16 RETURN C 1 FLOW I A + SUPPLY B (14) AIR I I AIR OPENING I AOPENING ` 3/4 L COMBUSTION 9/16 END VIEW (19) FRONT VIEW AIR INTAKE END VIEW (14) A B C D Model No. in. mm in. mm in. mm in. mm EL195UH045P24B EL195UH045P36B 17-1/2 446 16-3/8 416 16 406 7-5/8 194 EL195UH070P36B EL195UH070P48B EL195UH090P36C EL195UH090P48C EL195UH090P60C 21 533 19-7/8 505 19-1/2 495 9-3/8 238 EL195UH110P48C EL195UH110P60C EL195UH135P6OD 24-1/2 622 23-3/8 594 23 584 9-3/4 248 EL195UH/Page 13 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL (END) FILTER KIT 1-1/4 24-3/4 (32) III (16) (629) ill 1 1 — i 5/8 n -4 (16) Furnace A B Cabinet Catalog B RETURN Width Number in. mm in. mm A AIR B 87L96 18 457 16-3/4 425 OPENING AIR FLOW 5/8 C 87L97 21 533 18-3/4 476 (16) 23-1/2 ~ (597) D 87L98 25 635 23-3/4 603 I V J AIR FILTER/L 5/8 f (Furnished) (16) SIDE VIEW FRONT VIEW Optional Return Air Base (Upflow Applications Only-For use with B, C and D cabinets) CONDENSATE TRAP \' FURNACE - FRONT IF BASE - 3-1/4_,, O I 1 23(584) IS USED I1.4_123 � Overall J WITHOUT / (83) I (Maximum) 1 Minimum IAQ CABINET, i 11 (279) INDOOR AIR I t QUALITY RETURN AIR 2 Maximum 22.7/16 I Unit side return air 14(356) I (570) CABINET PLENUMI I Opening I Overall (PCO,Filter MUST J I Cabinet,etc.) COVER BOTH 1 — (Maximum) UNIT AND \ . RETURN4 s SIDE RETURN AIR BASE \ 7-1/4 5-5/8 AIR OPENINGS OPENINGS 1 (184) (143) i f (Either Side) \ - - - a 23 �17-1/2(446)B Width(50W98)� OPTIONAL RETURN (584) I 3/4 ."11 21 (533)C Width(50W99) AIR BASE 26-7/8 (19) 24-1/2(622)D Width(51W00) (683) SIDE VIEW NOTE-Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. 1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 1800 cfm or more of air(W x H):23 x 11 in.(584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field.There are cutting guides stenciled on the cabinet for the side return air opening.The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop,the largest opening height possible,up to 14 in. (356 mm), is preferred. EL195UH/Page 14 DIMENSIONS INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION Cased Uncased Model No (CX34-cased only) /` A B A B ' CX34 C33 in. mm in. mm in. mm in. mm CX34-18/24B-6F 033 24B 16-1/2 419 49-1/2 1257 13-7/8 352 46-7/8 1191 44010% . ' CX34-18/24C-6F C33-24C CX34-25B-6F C33-25B 18-1/2470 51-1/2 1308 15-7/8 403 48-7/8 1241 �I " I A 0X34-30B-6F C33-30B 20-1/2 521 53-1/2 1359 17-3/4 451 50-3/4 1289 \\ I CX34-30C-6F C33-300 I11 ' V CX34-31B-6F 033-31B 22-1/2572 55-1/2 1410 20-1/4 514 53-1/4 1353 I\ A CX34-36B-6F C33-36B 24-1/2622 57-1/2 1461 21-7/8 556 54-7/8 1394 ® B CX34-36C-6F C33-36C 24-1/2 622 57-1/2 1461 21-1/4 540 54-1/4 1378 ®11 CX34-38B-6F 033 38B 24-1/2 622 57-1/2 1461 22 559 55 1397 33 CX34-42B-6F C33-42B 24-1/2 622 57-1/2 1461 21-7/8 556 54-7/8 1394 (838) CX34-43B-6F C33-43B 27-1/2 699 60-1/2 1537 26-1/4 667 59-1/4 1505 p p 0X34-430-6F C33-43C 27-1/2 699 60-1/2 1537 25-3/4 654 58-3/4 1492 --- C33-44C 24-1/2 622 57-1/2 1461 21-1/2 546 54-1/2 1384 ofi • . ta CX34-44/48B-6F C33-48B 24-1/2622 57-1/2 1461 22-1/8 562 55-1/8 1400 0X34-44/480-6F 033-480 24-1/2 622 57-1/2 1461 21-1/2 546 54-1/2 1384 0X34-490-6F 033-490 29-1/2749 62-1/2 1588 28-1/2 724 61-1/2 1562 0X34-50/600-6F 033-50/60027-1/2 699 60-1/2 1537 24-3/4 629 57-3/4 1467 0X43-60D-6F 033-60D 25-1/2648 58-1/2 1486 24-3/4 629 57-3/4 1467 CX34-62C-6F 033-620 31-1/2 800 64-1/2 1638 30-5/8 778 63-5/8 1616 0X34-62D-6F 033-62D 29-1/2 749 62-1/2 1588 28-3/4 730 61-3/4 1568 B 33 1 _(838) HORIZONTAL POSITION iir„„ ---:„...v. . A B Model No. ' in. mm in. mm I� 0H33-36B-2F CH33-42B-2F 26-1/2 673 59-1/2 1511 // ¢ CH33-360-2F CH33-48C-2F ki ________ , // CH33-60D-2F I CH33-44/48B-2F 0H33-62D 31-1/2 800 64-1/2 1638 ® CH33-50/600-2F EL195UH/Page 15 OPTIONAL ACCESSORY DIMENSIONS4- INCHES (MM) FLUSH-MOUNT VENT TERMINATION KIT (51W11) 00 A 4 to,,, q71,*\, ... _, ti, With 2 or 2-1/2 in. (51 or 64 mm)PVC pipe With 3 in. (76 mm) PVC pipe Exhaust Intake Exhaust Intake (Behind Plate) (Behind Plate) � i — Seal all openings � i �� I I N (typical) �/ N. 42-3/8(60) -ii h I --- __ I_I�===- L I I J ^ ,7, t . ,,,, , t . , • . 1 , , -,, z .LLLLLi , -fid viiiiiiiii ////////z ® r/////iiiii, j\--. L---**---(:= 12(305) minimum 2(51)PVC pipe (recommended) 3(76) PVC pipe ♦ NOTE-PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided /2-1/2 to 2 in. (64 to 51 mm) Coupling 1 1 ______F___--I — 2-1/2(64) PVC pipe pi , EL195UH/Page 16 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) CONCENTRIC WALL CONCENTRIC ROOF TERMINATION APPLICATIONS TERMINATION APPLICATIONS 4 11 1--1 FLASHING (Not Furnished) / 12(305) OUTSIDE / Minimum WALL INTAKE Above AverageSnow 411/4, AIR EXHAUST Accumulation `/.►��•• \ EXHAUST \ AIR , .-0 A �r W'''' 0 ♦ El lig ®m� � J ��� � �Y, ..��� Gllr��.o SHEET METAL STRAP `'--may'- T 12(305) • (Clamp and sheet metal strap INTAKE CLAMP INTAKE Minimum must be field installed to support AIR (Not Furnished) AIR Above Grade the weight of the termination kit.) or Average Snow CLAMP L. Accumulation - 1 i T-T GRADE ' ' ' ' lA7 l.A-.7 71 M80/69M29/44W92 - 2 inch kits 60L46/44W93 - 3 inch kits See Installation Instructions for additional information. Note-Field provided reducer may be A B required to adapt larger vent pipe size to termination. Cat.No. in. mm in. mm 71M80 33 3/8 848 16 3/4 425 A lir- 69M29 (165) ��(152) (Ca (Canada) 29 737 15-1/2 394 ♦Si: - ,3-1/2 89)-2 in.kits 4-1/2 11 -3 in. kits ill 14 Y j_— ♦� AIR — EXHAUST 60L46 38-7/8 987 21-3/16 538 44W93 36-1/8 918 19-1/2 495 } -iY,. INTAKE AIR (Canada) ,1--ice,/ ELBOW TERMINATION Outdoor Exhaust Accelerator (Field Supplied) ASSEMBLY included with 71 M80/44W92 (Furnished) NOTE-Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT- RING KIT 15F74- 2 inch (51 mm) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION NON-DIRECT VENT APPLICATION NOTE -EXHAUST PIPE SHOWN Kit Contains Enough Parts For Two Installations / /(/ 12 in.(305 mm)-2 in.(51 mm)dia.exhaust pipe \ / ` 20 in.(508 mm)-3 in.(76 mm)dia.exhaust pipe �,/ ( maximum length without support ////// 12 in.(305 mm)-2 in.(51 mm)dia.exhaust pipe (� ---..,,,Iii\ ( l/ `-\ 20 in.(508 mm)-3 in.(76 mm)dia.exhaust pipe \\\ \ Xmaximum len th without yyO \ \,,,,41A\ g support 6 in.(152 mm) #8 in.(203 mm) maximum minimum NOTE-12 in.(305 mm)minimum height above NOTE-12 in.(305 mm)minimum height above average snow accumulation average snow accumulation (from bottom of vent pipe). (from bottom of vent pipe). EL195UH/Page 17 OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (51 mm) 22G44 (US) 3 inch (76 mm) 44J40 (US) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less thanl2 in.(305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. 8(203)MIN.Between Ends of Exhaust and Intake Pipe WALL SUPPORT 12(305)MAX.for 2(51)Dia.Exhaust 20(508)MAX.for 3(76)Dia.Exhaust j All 12 ►I (305) j .+__11 110"1 EXHAUST F�� 1/2(13) 6(152) I ~ LI AIR j--) CN—' FOAM INSULATION Maximum � LI �I r 1' IF—I (Field Furnished) INTAKE I I 6 INTAKE VTFr I I I AIR _ IV I t EXHAUST AIR I I , ° AIR \r ,i< I + (127) -± •) •+, � 12(305)Minimum ° ° 12(305)Minimum 1,8(203)MIN. lo. Above Grade or Average Above Grade or Average Snow Accumulation 5-1/2 Snow Accumulation iiiiiiiiiiiiiiir. GRADE 5�49)� GRADE 12(305)MAX.for 2(51)Dia. Exhaust T 20(508)MAX.for 3(76)Dia. Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (51 mm) 30G28 (WTK Canada) 3 inch (76 mm) 81J20 (WTK Canada) See Installation Instructions for additional information. Note-Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less thanl2 in.(305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT 12(305)MAX.for 2(51)Dia.Exhaust 20(508)MAX.for 3(76)Dia.Exhaust IA 1 12 (305) Pwl 7-1 j EXHAUST i �'� 1/2(13) 6(152) ( i I I AIR (k_,1 ri,c_ FOAM INSULATION Maximum �' 1 6 152 -LI� _I (Field Furnished) j i u��I MIN.) I INTAKE f I �' I AIR B V I t II EXHAUST INTAKE ' ; i I , o/ AIR AIR AriA __ 5 _� (127) �I 12(305)Minimum ° �' f.1-411-6(152)MIN. 12(305)Minimum Above Grade or Average 5-1/2 Above Grade or Average Snow Accumulation (140) Snow Accumulation 'ii�iiiiiiiiiiri. GRADE GRADE 12(305)MAX.for 2(51)Dia.Exhaust I 20(508)MAX.for 3(76)Dia.Exhaust EL195UH/Page 18 BLOWER DATA ELI95UH045P24B PERFORMANCE(Less Filter) ELI95UH070P48B PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds External Air Volume/Watts at Various Blower Speeds StaticHi h g Medium- Medium- Low Static HighMedium- Medium- Pressure High Low Hi h Low Low PressurePressure _ in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1140 455 920 365 765 295 710 265 0.00 2015 1005 1950 840 1870 730 1675_630 0.10 1135 445 900 360 765 290 690 255 0.10 1930 985 1915 830 1805 720 1650 615 0.20 1125 430 895 350 755 285 680 255 0.20 1880 965 1840 805 1760 695 1620 600 0.30 1090 415 870 340 725 280 660 250 0.30 1815 945 1775 790 1700 675 1560 580 0.40 1065 405 870 325 715 270 635 245 0.40 1740 925 1700 770 1630 655 1515 565 0.50 1020 390 825 315 675 260 605 235 0.50 1680 895 1625 750 1545 635 1455 545 0.60 945 365 780 300 640 250 555 225 0.60 1575 880 1555 720 1485 620 1380 530 0.70 910 350 740 295 585 240 505 220 0.70 115001 860 11450 700 1380 600 1310 515 0.80 790 325 670 275 510 225 455 205 0.80 114001 825 113801 680 1315 580 1230 495 0.90 735 310 575 255 460 220 390 195 0.90 1290 805 1270 655 1235 560 1145 480 EL195UH045P36B PERFORMANCE(Less Filter) EL195UH090P36C PERFORMANCE (Less Filter) External Air Volume/Watts at Various Blower Speeds External Air Volume/Watts at Various Blower Speeds StaticHi h g Medium- Medium- Low High Static g Medium- Medium- Pressure High Low High Low Low PressurePressure 9 in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 1605 700 1370 590 1160 475 1010 400 0.00 1630 715 1345 590 1090 475 885 385 0.10 1600 680 1355 565 1155 465 1015 390 0.10 1615 700 1320 580 1070 465 890 380 0.20 1550 645 1330 540 1150 445 1000 380 0.20 1580 675 1305 570 1070 455 890 370 0.30 1480 620 1295 520 1140 430 975 365 0.30 1525 620 1295 535 1060 435 890 360 0.40 1425 590 1280 490 1105 415 975 345 0.40 1480 615 1275 515 1055 430 885 350 0.50 1355 565 1190 460 1085 395 940 335 0.50 1415 565 1220 485 1030 410 860 330 0.60 1320 545 1165 435 1030 380 900 315 0.60 1350 535 1175 450 1005 390 835 310 0.70 1225 500 1110 425 980 355 855 310 0.70 1260 505 1115 415 955 360 785 290 0.80 1135 480 1050 395 920 330 780 280 0.80 1190 480 1010 380 880 325 740 285 0.90 1025 445 950 360 795 295 700 255 0.90 1060 435 930 360 795 295 655 250 ELI95UH070P36B PERFORMANCE(Less Filter) ELI95UH090P48C PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds External Air Volume/Watts at Various Blower Speeds StaticHighMedium- Medium- Static HighMedium- Medium- High Low Low High Low Low Pressure Pressure 5 in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 11585 685 1340_ 585 1095 480 880 380 0.00 2140 880 1895 780 1590 645 1350 550 0.10 1560 665 1320 565 1085 470 885 375 0.10 2110 850 1880 760 1585 635 1360 545 0.20 1515 630 1300 540 1080 460 880 370 0.20 2060 810 1835 725 1580 620 1360 520 0.30 1465 590 1275 520 1065 440 890 360 0.30 1990 765 1805 690 1550 585 1365 495 0.40 1410 570 1235 490 1050 420 875 350 0.40 1925 750 1755 655 1510 545 1330 470 0.50 1345 540 1195 470 1020 400 840 335 0.50 1830 700 1680 610 1455 525 1285 450 0.60 1275 510 1140 440 975 365 830 315 0.60 1720 645 1610 575 1390 480 1230 415 0.70 1195 485 1090 410 930 355 780 290 0.70 1600 615 1525 535 1300 465 1165 390 0.80 1105 460 995 380 850 325 730 275 0.80 1455 560 1410 495 1195 430 1035 365 0.90 985 420 890 345 770 300 650 255 0.90 1300 515 1305 465 11001 390 900 320 EL195UH110P48C PERFORMANCE(Less Filter) External Air Volume/Watts at Various Blower Speeds Static High Medium- Medium- Low Pressure High Low in.w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2000 910 1675 765 1360 635 1185 525 0.10 1980 895 1650 745 1370 610 1180 505 0.20 1935 855 1600 710 1400 590 1170 485 0.30 1875 830 1560 680 1370 570 1160 490 0.40 1800 785 1490 655 1325 545 1120 455 0.50 1725 720 1400 610 1295 515 1080 435 0.60 1630 685 1335 585 1185 480 1030 410 0.70 1530 665 1290 525 1100 435 940 385 0.80 1410 610 1190 485 985 400 790 365 0.90 1245 560 1000 430 925 380 715 315 EL195UH/Page 19 BLOWER DATA ELI95UH090P60C PERFORMANCE (Less Filter) Air Volume/Watts at Different Blower Speeds External Bottom Return Air, Side Return Air with Optional Return Single Side Return Air-Air volumes in bold require field Static Air Base, Return Air from Both Sides or Return Air from fabricated transition to accommodate 20 x 25 x 1 in. air filter Pressure Bottom and One Side. in order to maintain proper air velocity. in.w.g. Hi•h Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2445 1290 2235 1000 1875 840 1495 660 2445 1355 2180 1020 1785 850 1400 665 0.10 2430 1270 2220 985 1860 830 1500 650 2425 1335 2160 1010 1775 840 1405 655 0.20 2370 1260 2170 960 1875 805 1515 645 2390 1310 2135 985 1790 825 1435 645 0.30 2290 1220 2110 935 1855 785 1545 640 2305 1270 2080 960 1805 805 1455 640 0.40 2200 1190 2055 900 1835 765 1560 625 2230 1240 2015 925 1775 780 1460 630 0.50 2095 1155 1970 865 1785 735 1520 610 2150 1215 1965 900 1745 755 1460 620 0.60 2010 1145 1920 850 1725 715 1495 600 2055 1170 1890 865 1695 730 1440 605 0.70 1960 1120 1835 815 1655 690 1455 575 1955 1145 1805 840 1640 705 1415 590 0.80 1845 1080 1720 785 1570 665 1390 550 1825 1095 1705 815 1565 675 1360 565 0.90 1725 1040 1620 755 1490 645 1305 530 1715 1065 1590 775 1470 645 1290 540 ELI95UH110P60C PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds External Bottom Return Air,Side Return Air with Optional Return Single Side Return Air-Air volumes in bold require field Static Air Base, Return Air from Both Sides or Return Air from fabricated transition to accommodate 20 x 25 x 1 in. air filter Pressure Bottom and One Side. in order to maintain proper air velocity. in.w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2485 1515 2090 1070 1835 865 1380 660 2400 1475 2100 1075 1755 870 1320 655 0.10 2460 1475 2075 1040 1810 835 1390 650 2370 1440 2090 1060 1735 850 1330 645 0.20 2405 1445 2040 995 1790 820 1405 650 2320 1405 2060 1050 1720 835 1340 650 0.30 2335 1375 1990 980 1760 790 1460 635 2235 1350 2040 1030 1725 825 1350 645 0.40 2215 1355 1935 940 1740 775 1410 630 2165 1330 1975 970 1700 815 1330 632 0.50 2185 1310 1865 895 1680 750 1410 625 2040 1290 1920 945 1700 790 1325 620 0.60 2060 1270 1805 870 1630 720 1405 610 1960 1260 1845 910 1635 770 1340 620 0.70 1945 1235 1700 840 1605 700 1380 590 1865 1215 1750 890 1575 730 1295 600 0.80 1845 1210 1605 810 1505 670 1305 570 1715 1175 1590 840 1505 710 1280 590 0.90 1730 1150 1570 790 1470 660 1250 540 1630 1135 1490 685 1460 685 1235 565 EL195UH135P6OD PERFORMANCE(Less Filter) Air Volume/Watts at Different Blower Speeds External Bottom Return Air,Side Return Air with Optional Return Single Side Return Air-Air volumes in bold require field Static Air Base, Return Air from Both Sides or Return Air from fabricated transition to accommodate 20 x 25 x 1 in. air filter Pressure Bottom and One Side. in order to maintain proper air velocity. in.w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2595 1515 2245 2015 1780 890 1365 700 2540 1500 2185 1095 1715 880 1350 700 0.10 2570 1490 2235 1095 1765 875 1370 665 2525 1480 2165 1085 1725 870 1335 675 0.20 2440 1465 2135 1075 1745 865 1395 660 2440 1445 2120 1090 1725 865 1345 675 0.30 2340 1405 2075 1060 1755 845 1365 660 2345 1400 2060 1060 1715 850 1345 670 0.40 2255 1370 1995 1005 1680 825 1370 660 2220 1345 1955 1015 1685 820 1370 660 0.50 2095 1320 1915 960 1650 805 1335 650 2100 1310 1895 985 1620 805 1320 650 0.60 1995 1270 1840 935 1595 775 1320 630 2005 1285 1780 945 1605 790 1285 635 0.70 1900 1225 1755 905 1540 755 1270 615 1845 1235 1700 910 1510 740 1225 610 0.80 1740 1180 1650 875 1430 725 1190 590 1745 1185 1645 880 1450 720 1175 595 0.90 1580 1140 1535 840 1350 695 1145 570 1655 1160 1545 840 1380 705 1135 575 EL195UH/Page 20 REVISIONS Sections Description of Change Optional Accessories Removed Night Service Kit. DESIGN "�,�' A uI C 1 P 0 t.! 10 I 0 I V ui Nos CERTIFIEDTM ® ® 0446* •ll� r C www.ahridirectory.org © ,/MEMBER COMPANY CERTIFIEDR E G I S T E R E D CERTIFIED QUALITY ® — ® SYSTEMS Visit us at www.lennox.com J For the latest technical information,www.lennoxdavenet.com Contact us at 1-800-4-LENNOX NOTE-Due to Lennox'ongoing commitment to quality,Specifications,Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation,adjustment,alteration,service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2011 Lennox Industries,Inc.