HomeMy WebLinkAboutF16-0008_FP1_1478908438.pdf talilt:1 OF IV 1441911i4: Z t WI IS ir OW eP, KEYNOTES 0, ® Sprinklers shall not be required in bathrooms where the bathroom area does not exceed 55 ft2. Vail Fire&Emergency Services 04/01/16 B Sprinklers shall not be required in clothes closets, linen closets, and L,= pantries within dwelling units that meet all of the following conditions: (a) The area of the space does not exceed 24 ft2. MECH LAUNDRY BATH1 BATH2 BATH I (b) The least dimension does not exceed 3 ft. W210 ems, W208 W205 W211 E208 (c) The walls and ceilings are surfaced with noncombustible or YW limited-combustible materials as defined by NFPA 220. ' W D (7 0 C Sprinklers shall be required in all ceiling pockets unless each of the 0 216 '14 West Unit S, n'-r Riser I• I ® ";.' _, 0 following conditions are met: 1 rn _ ::DROOM1 CLOSET BATH2 LAUNDRY MECH. (a) The total volume of the unprotected ceiling pocket does not + 1' 1 • . I E207 E209 E204 E205 STOROA6GE E212 ° 'r exceed 100 cubic feet. .. 7 FURNACE -East Unit Sprinkler Risen. (b) The depth of the unprotected pocket does not exceed 36 in. (c) The entire floor under the unprotected ceiling pocket is Firepl ifr r ;., ix v� - 9 °. I • — • I 1 � / rotected by the sprinklers at the lower ceiling elevation1 - W1J1Al 1 ^ po �':° ® UP 1ya x 1�6 0 cam .9'-0" 1 I I 03-0 -0 / \,__, (d) Each unprotected ceiling pocket is separated from any adjacent ® 1 i—�I -rn ;,. unprotected ceiling pocket b a minimum 10 ft horizontal O � I • ®i 17� \ p g p Y ,'- 1 • �c 1-2 112 ♦ distance. FAMILY ROOM II / , 1-10csi \ 9 0'6 � Q (e) The unprotected ceiling pocket is constructed of noncombustible o \/ 1l4 f`:IIL� 1 .r ^ ' LJ al iti �! I /I= construction. W200 0 , 1+- �2-4 - •o �_ i, I '- / 1 • '.1�+ ` M • - i \/ „ _ „ _` (f) Quick response sprinklers are utilized throughout the FIRE PROTECTION CONTRACTOR 1\/ - , 0 o 0 1ili compartment. -*T ' • i \/ \ 4 v -11 "�� -4L'-°'�� �� 7 di _oma 11-7 HALL 1 -7 L2-0 9-7 �� 1 \ i - ���� I E201 1-0 -900 I v , __ 111 ��I i��_ „ o o O __ MINIMUM DISTANCE FROM SPRINKLER TO HEAT SOURCE MERIDIAN INTERMOUNTAIN o ` 1H 1 To8'-10° -2" 9'-0" 3'-0° II � O ^ Oma- ^b ' MIN DIST FROM SOURCE UP . ! 1-0 ®�® mem ra®a®� �' ` —� �' \/ 1 I HEAT SOURCE ORDINARY TEMP INTERMEDIATE TEMP PO BOX 3940 • ■ wimE, to . �� � :�� / \/ ', r _T L � o�10 1 /\ 1 ° Avon, Colorado 80620 0-101.. SIDE OF FIREPLACE 36" 12" FRONT OF FIREPLACE 60 36"I BEDROOM 1 CLOSET BEDROOM 2 1 1 I\ /\ � �\ �/ 970 748 8888 Office 11 O ---' 11 I WOOD BURNING STOVE 4211 12" 11141==AM- �'' W201 W202 W203 `\ i —� KITCHEN RANGE 18 911 970 827 9126 Fax 11,111717 �J\� II� 'u, � CLOSET6 .wII O WALL OVEN 18rr 911 HOT AIR FLUE 18" 9" or Ikr 0 11 • I ID UN-INSULATED DUCT 18" 9" it �0' ®o��aa UNINSULATED HOT WATER PIPE 12" 6" ELEV L®®a®�— a - - _ _ ilk _ Il • u, W204BEDROO 2 FAMILY ROOM H SIDE OF HOT AIR DIFFUSER 36" 12" � •M E203 iJJ 'l�a I FRONT OF HOT AIR DIFFUSER 36" 18" 8'-0° 4'-1° HOT WATER HEATER 6" 3" A c Protected by Main Level Sprinkler 4'-712" 11'-712° 2'-9" LIGHT FIXTURE (0-250 WATT) 6" 3" VERITAS West Unit East Unit LIGHT FIXTURE (250-499 WATT) 12" 6" 1 FIRE ENGINEERING,INC. MAX SPRINKLER SPACING 12364 W. Alameda Pkwy Ste. 135 One Sprinkler in a Room Lakewood, Colorado 80228 18 ft Between Sprinklers/9 ft from Wall 303-985-3300 Office 0Lower Level West/East 8' 4' 0' 8' More than One Sprinkler in a Room 303-985-5594 Fax 16 ft Between Sprinklers/8 ft from Wall SCALE: 1/8" = 1' 0" www.veritasfire.com k a ,Trl . li f •. 0 The protection area of coverage for each ice: Y ■ i 0^13* • § z• BMASTER EDROOM sprinkler in the small room shall be the If fir` { area of the room divided bythe number of 11.4%, .• `*�, E401 I sprinklers in the room per NFPA 13 11. 411 l n 1\ Section 8.6.2.1.2.1. 4x ti Nommommom - --. .