Loading...
HomeMy WebLinkAboutB11-0496 Exhaust Fans CR documents ARCHITECTURE Sal URBAN DESIGN INTERIOR DESIGN January 3o, 2017 JR Mondragon Town of Vail 42 W. Meadow Drive Vail, CO 81657 RE: Reference : B11-o496 Strata Vail Permit Drawings Revision 33 Dear JR: • We are submitting to the TOV building department for review and approval the following : • Toilet/ Bathroom Exhaust Fans Temporary solution prior to final design implementation : 1. Refer to the Attached BCER Letter toilet/ Bathroom Missing Exhaust Fans. 2. Request as part of conditional exception for TCO. Enclosures : • BCER Toilet/ Bathroom Missing Exhaust Fans Letter • TOV Inspection Notice 2101063320011. Sincerely, AEURoo A ;: , A \ I . E 202672 ,f 1/30/2017 OZ Architecture, Inc. 1/30/2017 Page sofi G:\zoo7\17ooy Lionshead Inn\CA\Permits\Bathroom Exhaust Fans\TOV JR Mondragon Bathroom Exhaust Fans OZ Letter DENVER PHONE: 303.861.5704 2017_0230.docx 3003 LARIMER STREET FAX 303.861.9230 DENVER BOULDER COLORADO SPRINGS DENVER,COLORADO 80205 WWW.OZARCH.COM TOWN OF AIL Inspection Summary Inspection Result: Fail Inspector: Florencio (JR) Mondragon Permit Type Inspection Type Address Construction Mechanical Final 705 W LIONSHEAD CIR (210106332001) (2101063320011) Inspection Date: 01/13/2017 Permit#: B11-0496.005 TMK: 2101063320011 Applicant name: The Wells Partnership - Lisa Email: lisa@wellspartnership.com Phone: Comments: 1. A305 no bath fan in shower A309 fire place not working 2. Inspector Signature 3. Applicant Signature BCER . en neeI/ng January 27, 2017 JR Mondragon Town of Vail Chief Building Inspector jmondragon@vailgov.com RE: STRATA VAIL—TOILET/BATHROOM MISSING EXHAUST FANS Dear Mr. Mondragon: As you are aware, during a recent inspection on the project, one of the toilet or bath rooms was noted to be missing an exhaust fan. This is noted on inspection notice 2101063320011 "A305 no bath fan in shower". BCER, OZ, and PCL have reviewed the drawings and installation and find there are approximately 22 instances of this condition; where the separated bath and toilet rooms only have one fan. The noted units are: A204, A302, A303L, A304L, A305L, A402, A403L,A404L, A405L, B407 (4 bathrooms affected in this unit), A502, A503L, A504L, A505L, B507 (4 bathrooms affected in this unit), and B702. Attached are two options that are proposed to resolve this issue. Option#1 replaces the existing ceiling mounted fan with a 120 CFM inline fan and located a grille in each room. The exhaust fan will be switched from both rooms. Option #2 adds a ceiling mounted TEF-1 to the room that is missing a fan,also adding the switch in the room to control it. Both of the two options meet all code requirements of the IMC, Table 403.3,and the optimal solution will be implemented for each situation. We are requesting that the Town of Vail allow the Temporary Certificate of Occupancy to be issued without these issues being resolved(installed). As part of the TCO conditional exception,the doors between the toilet and bath rooms will be removed or disabled to create a single room. The design and construction teams will have the solutions implemented prior to the Certificate of Occupancy being issued. Please let us know if you have any questions or concerns with these options that we can address. Thank you for your understanding. rr4 Sincerely, 9 ON L I CE�ji 1 BCER ENGINEERING,INC. o,•� " `�c^+f+ • v 329 0: f it • Michael D. Schroeder, P.E. ��S�. Director of Engineering 1��/CNA. Er�:V17 Associate Principal COLORADO SPRINGS OFFICE CORPORATE OFFICE TAMPA OFFICE 10807 NEW ALLEGIANCE DR,SUITE 400 5420 WARD ROAD,SUITE 200 4511 NORTH RIMES AVE,SUITE 200 COLORADO SPRINGS,COLORADO 80921 ARVADA,COLORADO 80002 TAMPA,FLORIDA 33614 719533.1112 303.422.7400 813.449.4324 www.BCER.com TEF-2 41 1 r .�•rg I I0 FON-4 0 n 4) `Y r� Option n I Replace TEF-I ceiing mounted 60 CFM fan with _ • In TEFL r 1 m CFM inline fan. Imwit new•exhaust grilles in t toilet room CF main bathroom with new duct for sound 6��Round ill Milirrauenuatinn to now inline e7ehaust f:i f `❑ •!IS'txlS" • Interlock new TEF-2 to opet ate with either the bathroom or 5%) ('rl toilet room switches F rill w J - 11 • 85 CFM I I ilir 421 I I 16E ,..,... eEmui'll 0 6 • tt,,, • ♦iitl 32x12 _ _ _� . I • • 1 'P FALI .7-.7 ..mm R.al AMI.!•,,, l 'Ill ,1 '— -1 - M -- ;, b 30"x24"05 C P i t v 4 51 40620 x6 n tt rI —— - • 51 �5Q 771 —__ A305 Lock-Off Reference M2. 12 TEF-II 6.47 0 Q FCW-4 1 I Option#2 Add a second TEF-I ceiling mourned 60 CFM i ��• •1 .ril. i fan in the main bathroom and duel to the existing duel run •'�'K 6•Round 111, �Add a new switch in the toilet room to control the existing I ',"Xx1pn ,II] fan. Reused the existing switch and connect ill the new S ti pi V •. cxh:nt.ct Ian in the main bathmrnn, I - FII 17 Milla85 GFM I qr ■ ' f y — / I 41,0 r 64) e --.7 '1' i II l — — TEF-1 0 _1_ r l 1 Mil ...._la, t. AN il liii `-. 1 ok CI 83 _ II k 0 5onx2411 O 10' I,{ )(411 _ � . , ■ ■ PP i , / a 1 711: 51 SID 04200 b° A305 Lock-Off Reference M2. 12