January 3o, 2017
JR Mondragon
Town of Vail
42 W. Meadow Drive
Vail, CO 81657
RE: Reference : B11-o496 Strata Vail Permit Drawings Revision 33
Dear JR:
• We are submitting to the TOV building department for review and approval the following :
• Toilet/ Bathroom Exhaust Fans Temporary solution prior to final design implementation :
1. Refer to the Attached BCER Letter toilet/ Bathroom Missing Exhaust Fans.
2. Request as part of conditional exception for TCO.
Enclosures :
• BCER Toilet/ Bathroom Missing Exhaust Fans Letter
• TOV Inspection Notice 2101063320011.
Sincerely,
AEURoo
A ;:
, A \
I . E
202672 ,f
1/30/2017
OZ Architecture, Inc.
1/30/2017
Page sofi
G:\zoo7\17ooy Lionshead Inn\CA\Permits\Bathroom Exhaust Fans\TOV JR Mondragon Bathroom Exhaust Fans OZ Letter DENVER PHONE: 303.861.5704
2017_0230.docx 3003 LARIMER STREET FAX 303.861.9230
DENVER BOULDER COLORADO SPRINGS DENVER,COLORADO 80205 WWW.OZARCH.COM
TOWN OF AIL Inspection Summary
Inspection Result: Fail
Inspector: Florencio (JR) Mondragon
Permit Type Inspection Type Address
Construction Mechanical Final 705 W LIONSHEAD CIR (210106332001) (2101063320011)
Inspection Date: 01/13/2017
Permit#: B11-0496.005
TMK: 2101063320011
Applicant name: The Wells Partnership - Lisa
Email: lisa@wellspartnership.com
Phone:
Comments:
1. A305 no bath fan in shower
A309 fire place not working
2. Inspector Signature
3. Applicant Signature
BCER .
en neeI/ng
January 27, 2017
JR Mondragon
Town of Vail Chief Building Inspector
jmondragon@vailgov.com
RE: STRATA VAIL—TOILET/BATHROOM MISSING EXHAUST FANS
Dear Mr. Mondragon:
As you are aware, during a recent inspection on the project, one of the toilet or bath rooms was noted to be
missing an exhaust fan. This is noted on inspection notice 2101063320011 "A305 no bath fan in shower".
BCER, OZ, and PCL have reviewed the drawings and installation and find there are approximately 22
instances of this condition; where the separated bath and toilet rooms only have one fan. The noted units are:
A204, A302, A303L, A304L, A305L, A402, A403L,A404L, A405L, B407 (4 bathrooms affected in this unit),
A502, A503L, A504L, A505L, B507 (4 bathrooms affected in this unit), and B702.
Attached are two options that are proposed to resolve this issue.
Option#1 replaces the existing ceiling mounted fan with a 120 CFM inline fan and located a grille in each
room. The exhaust fan will be switched from both rooms.
Option #2 adds a ceiling mounted TEF-1 to the room that is missing a fan,also adding the switch in the room
to control it.
Both of the two options meet all code requirements of the IMC, Table 403.3,and the optimal solution will be
implemented for each situation.
We are requesting that the Town of Vail allow the Temporary Certificate of Occupancy to be issued without
these issues being resolved(installed). As part of the TCO conditional exception,the doors between the toilet
and bath rooms will be removed or disabled to create a single room. The design and construction teams will
have the solutions implemented prior to the Certificate of Occupancy being issued.
Please let us know if you have any questions or concerns with these options that we can address. Thank you
for your understanding.
rr4
Sincerely, 9 ON L I CE�ji 1
BCER ENGINEERING,INC. o,•� " `�c^+f+
•
v 329 0: f
it •
Michael D. Schroeder, P.E. ��S�.
Director of Engineering 1��/CNA.
Er�:V17
Associate Principal
COLORADO SPRINGS OFFICE CORPORATE OFFICE TAMPA OFFICE
10807 NEW ALLEGIANCE DR,SUITE 400 5420 WARD ROAD,SUITE 200 4511 NORTH RIMES AVE,SUITE 200
COLORADO SPRINGS,COLORADO 80921 ARVADA,COLORADO 80002 TAMPA,FLORIDA 33614
719533.1112 303.422.7400 813.449.4324
www.BCER.com
TEF-2
41 1
r .�•rg
I
I0 FON-4 0
n 4)
`Y r�
Option n I Replace TEF-I ceiing mounted 60 CFM fan with _ • In
TEFL r 1 m CFM inline fan. Imwit new•exhaust grilles in t
toilet room CF main bathroom with new
duct for sound 6��Round ill Milirrauenuatinn to now inline e7ehaust f:i f `❑ •!IS'txlS" •
Interlock new TEF-2 to opet ate with either the bathroom or 5%)
('rl
toilet room switches F rill
w J -
11
•
85 CFM I
I ilir
421 I
I
16E ,..,... eEmui'll 0
6 •
tt,,, •
♦iitl 32x12 _ _ _� .
I •
• 1 'P FALI .7-.7 ..mm R.al AMI.!•,,, l 'Ill
,1 '— -1 -
M -- ;,
b 30"x24"05
C
P i t v
4 51 40620 x6
n tt
rI —— - • 51 �5Q
771 —__
A305 Lock-Off
Reference M2. 12
TEF-II 6.47
0
Q FCW-4
1 I
Option#2 Add a second TEF-I ceiling mourned 60 CFM i ��• •1 .ril.
i
fan in the main bathroom and duel to the existing duel run •'�'K 6•Round 111,
�Add a new switch in the toilet room to control the existing I ',"Xx1pn ,II]
fan. Reused the existing switch and connect ill the new S ti pi V
•.
cxh:nt.ct Ian in the main bathmrnn, I -
FII 17 Milla85 GFM I qr ■
' f y — / I
41,0 r
64) e --.7
'1' i II l — — TEF-1 0
_1_ r
l
1
Mil ...._la,
t.
AN il liii `-. 1 ok
CI
83 _
II k 0
5onx2411
O
10' I,{
)(411 _
� . , ■
■
PP i , / a
1 711:
51 SID 04200 b°
A305 Lock-Off
Reference M2. 12