HomeMy WebLinkAboutA17-0003_GE ATP 1000.pdf • ' interlogix A UTC Fire&Security Company ATP1000 Touchpad/Display Installation Instructions • Table 2 describes the maximum wire lengths allowed Product summary between the touchpad and the panel. The ATP1000 lets you control all programming and operation Table 1.Touchpad power usage of compatible security systems(see the"Specifications" Section). Current(mA) Conditions 110 Maximum alarm current with the buzzer sounding The large 2-line, 16-character display provides easy to read and the touchpad illuminated from a button press messages to indicate the current status of the system. The 60 Typical operation touchpad includes police,fire, and auxiliary panic buttons that can be activated anytime.A built-in speaker provides alarm, 12 Power saving mode(no panel AC power) status, and button-press sounds.A swing-down door reveals a label with basic system operating commands. The door can be Table 2.Maximum touchpad wire lengths removed by simply opening it past its stop point. The door can Wire Gauge(Unshielded Max.Touchpad Wire Length also be reattached later if desired. or Shielded) Between Touchpad and Panel 18 750 feet Tools and equipment needed 22 300 feet • 4-conductor, 22-or 18-gauge wire Installing the Mounting Plate • Screwdriver 1. Separate the mounting plate from the touchpad by first • #6 screws and anchors(included) loosening the screw,then lift the touchpad away from the • Panhead screws for gang box installation mounting plate (see Figure 1). • Saw or utility knife for cutting wallboard Figure 1.Separating touchpad from mounting plate Installation Loosen screw, Installation guidelines Ng • Mount the touchpad in an environmentally controlled area (32°F to 120°F/0°C to 49°C). • When mounting the touchpad, allow at least 3 inches below it for the swing-down covers, • Do not exceed the maximum available power. See the panel installation instructions for maximum available [then lift touchpad. power. �. • Table 1 describes the power used by the touchpad. — P/N 466-2100•REV I•January 2011 1 2. For wall mounting, place the mounting plate on the wall Attaching the Touchpad to the Mounting Plate and mark the mounting holes (see Figure 2). Be sure to Align the tabs at the top of the mounting plate with the slots on leave a 3-inch clearance below for the touchpad door to the touchpad and swing the touchpad bottom toward the open. mounting plate. Gently tighten the screw into the bottom of the touchpad. Figure 2.Mounting hole locations Power up and Bus communication Mounting Holes After making all wiring connections from the touchpad to the panel, you are ready to power up the panel and verify correct communication between the touchpad and the panel. Upon power up,the panel scans the bus for connected devices, assigns a unit number to each bus device, and automatically • Mounting Holes rr learns the device ID number of each bus device. 1. Verify that all wiring between the panel and touchpad is 3. Insert anchors into the wall at the marked locations where correct. studs are not present. 2. Connect the panel battery and restore AC power. 4. Align the mounting plate holes with the wall or gang box Alphanumeric touchpads briefly show SCANNING BUS screw holes and secure the back plate using the screws DEVICES, then display date and time. provided. Note: Steps 3 through 9 are optional. Note: Do not over tighten screws or the mounting plate may bind and prevent the touchpad from mounting 3. At the touchpad, enter program mode by pressing 8+ properly. installer/dealer code (default=4321)+0+0.The touchpad should display SYSTEM PROGRAMMING. 5. For wall-mount installations, cut a hole in the wall in the wire access area of the mounting plate to pull the wiring 4. Press E and the display shows SECURITY. cable through. 5. Press A or B until the display shows ACCESSORY MODULES,then press E.The display should read BUS Wiring the Touchpad to the Panel DEVICES. 1. Remove panel AC and backup battery power. 6. Press E.The display shows the lowest device address 2. Run a 4-conductor, 18-to 22-gauge wire from the panel to and its ID.The following example shows what a device the touchpad location (see Figure 3). address display may look like: UNIT-ID 3. Connect the touchpad +12V, BUS A, BUS B, and GND 0-02110185* terminals to the matching panel terminals (see Figure 3 for *The 8-digit SuperBus ID number is also located on a label touchpad terminal identification) on back of the touchpad. 7. Press A or B to cycle through all bus device addresses Figure 3.Touchpad wiring connections until the touchpad appears. •• '' • ' • •-• ••• "'"'-.. . 8. After verifying the touchpad device ID, press c repeatedly -„ until the display shows SYSTEM PROGRAMMING. o , : , :: • • 9. Press A or B until the display shows EXIT • *' 4 no • PROGRAMMING READY,then press E. The touchpad 7 Bus A ii i ii miut should show the date and time display. } +i2v "" • Programming w • To program options for the newly installed touchpad (such as key beeps)see the specific panel installation instructions. 2 ATP1000 Touchpad/Display Installation Instructions Connecting the touchpad for system 2. Connect the cable plug onto the panel Programming Touchpad Header pins(see Figure 4). programming only 3. Reconnect the AC and backup battery power.The touchpad briefly displays***********, SCANNING BUS For installations that don't include an alphanumeric touchpad DEVICES, then shows a time and date display. as a permanent part of the system, you can connect one for system programming to the Programming Touchpad Header Note: If the touchpad does not respond as described in on the panel. step 3,there may be a bus conflict.To correct this, change the touchpad unit number as described in the section To do this you must first connect a Programming Touchpad "Changing the Touchpad Unit Number." Cable(60-791)to the touchpad wires(see Programming Touchpad Cable Installation Instructions-466-1604, included Removing the programming touchpad from Concord with the cable). Then, use the appropriate procedure for panels with software versions 1.0-1.6: connecting the touchpad. To prevent a trouble condition, you must delete the To connect a programming touchpad to a Concord programming touchpad unit number from Concord panel Express, Concord, or Concord Ultra panel with software memory before disconnecting it. version 2.0 or later: 1. After programming is completed, return to the 1. With the panel powered up, connect the cable to the ACCESSORY MODULES menu, then press E.The Programming Touchpad Header(see Figure 4). display should read BUS DEVICES. 2. Press E.The display shows the lowest unit number and its Caution: When using the ATP1000 as a programmable device name. touchpad, be careful not to touch the circuit board exposed on the pack. 3. Press A or B until the display shows the programming touchpad unit number. Figure 4.Connecting a Programming Touchpad—Concord 4. Press D to delete the device and its unit number from Express Shown,Concord Similar panel memory. The display shows: UNIT- TYPE 14-NONE Programmi♦g Touchpad Header Pins 5. Exit program mode and disconnect the programming cable from the panel header. I® ffiMHHHHHHI TH00 Testing 9 Q - . Note: Contact the central monitoring station before T activating alarms,to avoid dispatching local police and fire departments. Test the touchpad by arming/disarming the system, activating the touchpad panics, bypassing sensors, and by turning chime 2. Activate the touchpad by pressing 8+CODE+0+2. and lights on/off to verify correct operation. Refer to the panel 3. Enter program mode by pressing 8+ installer/dealer User's Manual for complete system operating instructions. CODE+0+0 and program the panel using the panel Installation Instructions. Adjusting display brightness and contrast 4. When programming is completed, simply disconnect the The touchpad display can be adjusted for easier viewing to programming touchpad. help compensate for lighting conditions in the touchpad To connect a programming touchpad to a Concord panel location. with software versions 1.0-1.6: The brightness adjustment lightens or darkens the background. 1. Disconnect AC and backup battery power. The contrast adjustment lightens or darkens the text. ATP1000 Touchpad/Display Installation Instructions 3 To adjust display brightness: Changing the touchpad unit number(Concord 1. Enter user programming mode by pressing 9+ user, partition, or system master CODE.The display shows panels with software version 1.0-1.6 only) SYSTEM MENU, then TIME AND DATE (Concord panels with software versions 1.0-1.6 display Use the following guidelines when changing device unit USER CODES.) numbers to avoid communication conflicts between bus devices and the panel: 2. Press B until the display shows OPTIONS,then press E. • The display shows DOWNLOADING ON/OFF(current All bus devices with DIP switches (LED Touchpads, setting). ESMs, HIMs, etc.)must be set to the desired unit number before applying power and entering program mode. 3. Press B twice and the display shows TOUCHPAD BRIGHTNESS 2(default setting). • Whenever possible, assign touchpad unit numbers before all other panel programming. 4. Enter a setting from 0 (darkest background)to 3 (brightest background),then press E. To change the touchpad unit number: 5. The display flashes the entered selection, then stops after 1. At the touchpad, press and hold the D and 6 buttons pressing E and displays the new setting and brightness together for at least 2 seconds.The display should show level. DA n,where n is the current touchpad unit number(000- 6. Exit user programming mode. 015). Note:At this time,the touchpad is in configuration mode To adjust display contrast: and no longer communicating to the panel. The system 1. Enter configuration mode by pressing the D and 6 buttons may immediately indicate a bus failure. Ignore the failure together for at least two seconds.The display shows DA and continue with the procedure. The bus failure will clear nnn. after successfully changing the touchpad unit number. 2. Press and release the 1 and 2 buttons together 2. Press E.The display shows ENTER_. repeatedly, until the desired contrast level is displayed. 3. Enter the desired three digit unit number(000-015), then 3. Press c and the display briefly shows DONE,then shows press E.The display shows DA n,where n is the new the time and date. touchpad unit number. 4. Do not use unit number 15 in Concord RF systems. Troubleshooting 5. Press c to exit from the configuration mode. Problem Action/Solution Note: If the new touchpad unit number was previously Touchpad doesn't Check for correct wiring connections at learned by the panel, communication between the power up(no display touchpad and panel terminals. touchpad and the panel begins immediately. However, if and no beeps when the new touchpad unit number has never been learned by buttons are pressed). Make sure panel battery is connected correctly and that the panel transformer is the panel, continue with step 6. plugged in. 6. Force the panel to scan bus devices as follows: Make sure panel transformer is not plugged into an electrical outlet controlled by a switch. • For systems where this is the only installed touchpad, Relocate transformer to an unswitched outlet remove panel AC and battery power,then re-apply location,if necessary. power. Touchpad display Check the touchpad display contrast setting. appears blank,but It may be set to 0(no display). • For systems with more than one touchpad, go to beeps sound when another system touchpad and enter 8+ buttons are pressed. installer/dealer CODE (default=4321)+ 0+ 1.The Touchpad display Check for correct bus wiring connections display shows SCANNING BUS DEVICES,then a shows a flashing*, (green and white wires)at touchpad and time and date display. indicating a trouble panel terminals. condition and system The touchpad and all other bus devices should operate doesn't respond to Make sure touchpad unit number is set to a P P commands from different number than all other bus devices. If correctly and any bus failures should be cleared. touchpad. necessary,change the touchpad unit number (see procedure on this page).(Concord Note: If the panel still indicates a bus failure the panel may panels with software versions 1.0-1.6 only.) have previously learned a unit number that is no longer 4 ATP1000 Touchpad/Display Installation Instructions used by any bus device. See the specific panel Installation FCC compliance FCC Part 15 Information to the User Instructions for more information on deleting unused unit Changes or modifications not expressly approved numbers. by Interlogix can void the user's authority to operate the equipment. Specifications FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, Compatibility Concord,Concord Express,Concord Ultra pursuant to part 15 of the FCC Rules.These Power requirements 12 VDC nominal(see Figure 1 for additional limits are designed to provide reasonable power requirements) protection against interference in a residential installation. Operating temperature 32°to 120°F(0°to 49°C) This equipment generates,uses,and can radiate Humidity 95%relative,non-condensing radio frequency energy and,if not installed and used in accordance with the instructions,may Dimensions 5.0"x 4.5 x.75"(L x W x D) cause harmful interference to radio communications. However,there is no guarantee that interference will not occur in a particular installation. Regulatory information If this equipment does cause harmful interference to radio or television reception,which can be Manufacturer UTC Fire&Security Americas Corporation, Inc. determined by turning the equipment off and on, 1275 Red Fox Rd.,Arden Hills, MN 55112-6943, the user is encouraged to try to correct the USA interference by one or more of the following UL listings UL 985 Household Fire Warning System Units measures: UL 1023 Household Burglar-Alarm System Units • Reorient or relocate the receiving UL1610 Central Station Burglar-Alarm Units antenna. (Commercial Burglary) • Increase the separation between the Note:See specific panel Installation Instructions for complete UL installation requirements for the equipment and receiver. system you are installing • Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. Contact information For contact information, see www.utcfireandsecurity.com or www.interlogix.com. For technical support,Toll-free: 888.437.3287 in the US including Alaska, Hawaii, Puerto Rico, and Canada. Outside the tool-free area: Contact your dealer. Copyright©2011 Interlogix, a UTC Fire&Security Company. All rights reserved. ATP1000 Touchpad/Display Installation Instructions 5