Loading...
HomeMy WebLinkAboutA17-0003_System Sensor Outdoor NAC.pdf Fire Alarm Systems I SS-SRK Two-wire, Wall-mount Outdoor Strobe (red) 0 BOSCH Invented for life SS-SRK Two-wire, Wall-mount Outdoor Strobe (red) ► Plug-in design with tamper-resistant, rainproof (NEMA 3R) construction ► Field-selectable settings of 15 cd, 15/75 cd,30 cd, i: : 75 cd,95 cd, 110 cd,and 115 cd L l - ' ► Shorting spring on mounting plate for continuity check r i 1 before installation ' , R ► Outdoor wall mounting a gi The SS-SRK Strobe, one of the System Sensor SpectrAlert Functions Advance notification appliances, simplifies installations Strobe with features such as plug-in designs, instant feedback messages to ensure correct installation of individual When wired as a primary-signaling notification appliance, devices, and field-selectable candela settings. This strobe the strobe complies with the Americans with Disabilities Act is designed for outdoor wall mounted applications. (ADA) requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage SpectrAlert products can be used in either DC or full-wave range. The strobe light consists of a xenon flash tube and rectified (FWR) systems (12 V or 24 V). If required,the associated lens and reflector system. SSMDL module can be used to provide synchronization. For 24 V applications, the total number of strobes on a Note Full-wave Rectified (FWR) voltage is a single NAC must not exceed 40, with a maximum loop non-regulated, time-varying power source that resistance of 120 O. For 12 V applications,the total number is used on some power supply and panel of strobes must not exceed 12, with a maximum loop outputs. resistance of 30 O. Note SpectrAlert products set at 15 cd and 15/75 cd automatically work on either 12 V or 24 V power supplies.The products are not listed for Certifications and Approvals 12 V operating voltages when set to any other System Sensor holds the Listings and Approvals for these candela settings. strobes: Region Certification USA UL UVAV:Visual Signal Appliances for Fire Protective Signaling Systems(UL1638) FM CSFM 7300-1653:187 NYC-MEA 452-05-E www.boschsecurity.com 2 I SS-SRK Two-wire, Wall-mount Outdoor Strobe (red) ADA Complies with Americans with Disabilities Strobe Output(cd)1 Act 95 cd 70 cd FCC Complies with Federal Communications Commission FCC Rules,Part 15,Class B 110 cd 110 cd digital device 115 cd 115 cd NEMA Rainproof per UL50(NEMA 3R) 1 When these strobes are used at low temperatures, listed candela ratings must be reduced in accordance with this table. Installation/Configuration Notes Mounting Considerations Dimensions 5.6 in x 4.7 in x 2.5 in (Height x Width x Depth): (142 mm x 119 mm x 64 mm) Note These strobes are for wall mounting only! Power Requirements For outdoor use,these strobes wall mount on the supplied outdoor back box. Current Draw,UL maximum at 8 V to 17.5 V DC FWR Wiring Considerations The input terminals on the universal mounting plate accept 15 cd: 123mA 128 mARMS solid wires between 12 AWG (2.3 mm)to 18 AWG (1.2 mm). 15/75 cd: 142 mA 148mARMS Current Draw,UL maximum at 16 V to 33 V DC FWR Parts Included ■ 15 cd: 66 mA 71 mA RMS Quant. Component 15/75 cd: 77 mA 81 mA RMS 1 Strobe 30 cd: 94 mA 96 mA RMS 1 Universal mounting plate(MP120K) 75 cd: 158 mA 153 mA RMS 1 Outdoor back box(SA-WBB) 95 cd: 181 mA 176 mA RMS 1 Hardware pack 110 cd: 202 mA 195 mA RMS 1 Literature pack 115 cd: 210 mA 205 mA RMS Voltage Technical Specifications 1 Nominal: Regulated 12 VDC/FWR or Regulated 24 VDC/FWR Environmental Considerations Operating Range: 12V nominal:8 V to 17.5 V or 24 V nominal:16 V to 33 V Temperature(operating): -40°F to+151°F(-40°C to+66°C) Trademarks Mechanical Properties Trademark names are used throughout this document. In Candela Selections: 15 cd1,15/75 cd1,30 cd2,75 cd2, most cases,these designations are claimed as trademarks 95 cd2,110 cd2,and 115 cd2 or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol 1 When set at these settings,the devices automatically work in every occurrence of a trademark name, Bosch Security on both 12 V and 24 V power supplies. The 15/75 cd Systems, Inc. uses the names only in an editorial fashion selection is listed at 15 cd but provides 75 cd on axis. and to the benefit of the trademark owner with no intention 2 The strobe is not listed for 12 V operating voltages when of infringing the trademark. set to these selections. When using a 12 V control panel, SpectrAlert is a trademark of System Sensor in the United States and other this device yields required light output only in the 15 cd and countries. 15/75 cd settings. System Sensor is a registered trademark or a trademark of System Sensor, Strobe Output(cd)1 a brand of Honeywell International Inc.,in the United States and other coun- tries. Listed Candela Candela rating at-40°F(-40°C) 15 cd Do not use below+32°F(0°C) 15/75 cd Do not use below+32°F(0°C) 30 cd Do not use below+32°F(0°C) 75 cd 44 cd SS-SRK Two-wire, Wall-mount Outdoor Strobe (red) 13 Ordering Information SS•SRK Two-wire,Wall-mount Outdoor SS-SRK Strobe(red) Designed for outdoor wall-mounted applica- tions Accessories SSMDL Synchronization Module(red) SSMDL Red,24VDC device that can connect to two Style Y(Class B)circuits or one Style Z(Class A)circuit and synchronize System Sensor SpectrAlert horns,strobes,and horn strobes www.boschsecurity.com 4 I SS-SRK Two-wire, Wall-mount Outdoor Strobe (red) Americas: Europe,Middle East,Africa: Asia-Pacific: Represented by Bosch Security Systems,Inc. Bosch Security Systems B.V. Robert Bosch(SEA)Pte Ltd,Security Systems 130 Perinton Parkway P.O.Box 80002 11 Bishan Street 21 Fairport,New York,14450,USA 5600 JB Eindhoven,The Netherlands Singapore 573943 Phone:+1 800 289 0096 Phone:+31 40 2577 284 Phone:+65 6258 5511 Fax:+1 585 223 9180 Fax:+31 40 2577 330 Fax:+65 6571 2698 security.sales@us.bosch.com emea.securitysystems@bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.com www.boschsecurity.com ©Bosch Security Systems Inc.2010 I Data subject to change without notice T3953784715 I Cur:en-US,V4,4 Jul 2010