F16-0052 equipment.pdf
1110 csicioo'a05, Vail Fire&Emergency Services 10/17/16 Meridian Intermountain Fire Protection Equipment Data Holm Residence 738 Sandy Lane Item# Description Manufacturer 1 ABOVE GROUND PIPE NIBCO 2 AQAUTHERM (REDPIPE) AQUATHERM 3 CONTROL VALVES NIBCO 4 PRESS. REDUCING VALVE ZURN 5 BACKFLOW DEVICE AMES 6 READY RISER TYCO 7 SPRINKLERS TYCO 8 SPRINKLER ACCESSORIES TYCO 9 FDC EQUIPMENT GUARDIAN 10 CHECK VALVE NIBCO sgiti pi NIBCO" AHEAD OF THE41joi ilh."41joi � pn Copper Water Tube continued Vail Fire&Emer.ency Services DIMENSIONAL DATA-COPPER WATER TUBE-TYPE "K" TYPE"K" Hard Drawn: 20-ft.(6.1m)Straight Lengths Soft Annealed: 20-ft.(6.1m)Straight Lengths,or 40-ft.(12.2m)and 60-ft.(18.3m)Length Coils(to and including size 1 1/2) Usage: For underground service and general purpose plumbing and heating installations under severe conditions. Tolerances Hard Drawn Soft Annealed (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Bursting Safe Working Nominal Diameter Thickness Per Foot Pressure" PressureB Pressure" Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.035 (0.89) 0.145 (0.07) N/A N/A 1612 (111) N/A N/A 913 (63) 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.049 (1.24) 0.269 (0.12) N/A N/A 1675 (115) N/A N/A I 960 (66) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.049 (1.24) 0.344 (0.16) 9840 (678) 1337 (92) 4535 (313) 758 (52) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.049 (1.24) 0.418 (0.19) N/A N/A 1104 (76) N/A N/A 626 (43) 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.065 (1.65) 0.641 (0.29) 9300 (641) 1278 (88) 4200 (290) 724 (50) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.065 (1.65) 0.839 (0.38) 7200 (496) 982 (68) 3415 (235) 557 (38) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.065 (1.65) 1.040 (0.47) 5525 (381) 797 (55) 2800 (193) 452 (31) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.072 (1.83) 1.360 (0.62) 5000 (345) 742 (51) 2600 (179) 420 (29) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.083 (2.11) 2.060 (0.93) 3915 (270) 652 (45) 2235 (154) 370 (26) 21/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.095 (2.41) 2.930 (1.33) 3575 (246) 597 (41) N/A N/A 338 (23) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.109 (2.77) 4.000 (1.81) 3450 (238) 578 (40) N/A N/A 328 (23) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.120 (3.05) 5.120 (2.32) N/A N/A 549 (38) N/A N/A 311 (21) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.134 (3.40) 6.510 (2.95) 3415 (235) 540 (37) N/A N/A 306 (21) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.160 (4.06) 9.670 (4.39) 3585 (247) 517 (36) N/A N/A 293 (20) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.192 (4.88) 13.900 (6.30) 3425 (236) 520 (36) N/A N/A 295 (20) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.271 (6.88) 25.900 (11.75) 3635 (251) 553 (38) N/A N/A 314 (22) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.338 (8.59) 40.300 (18.28) N/A N/A 553 (38) N/A N/A 314 (22) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.405 (10.29) 57.800 (26.22) N/A N/A 555 (38) N/A N/A 314 (22) Note:Information and data contained in these charts,as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. ABased on actual laboratory test data provided by Copper Development Association,Inc. 'Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668 kPa). 'Based upon 150°F(65.6°C)with an allowable stress of 5100 psi(359 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com sglti OF pi NIBCO 41AHEAD OF THE FLOW® pn iCID].16'1j Vail Fire&Emer•enc Services DIMENSIONAL DATA-COPPER WATER TUBE-TYPE "L" TYPE"L" Hard Drawn: 20-ft.(6.1m)Straight Lengths Soft Annealed: 20-ft.(6.1 m)Straight Lengths,or 40-ft.(12.2m)and 60-ft.(18.3m)Length Coils(to and including size 1 1/2) Usage: For general purpose plumbing and heating conditions. Tolerances Hard Drawn Soft Annealed (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Bursting Safe Working Nominal Diameter Thickness Per Foot PressureA PressureB PressureB Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.030 (0.76) 0.126 (0.06) N/A N/A 1367 (94) N/A N/A 775 (53) 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.035 (0.89) 0.198 (0.09) N/A N/A 1168 (81) N/A N/A 662 (46) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.040 (1.02) 0.285 (0.13) 7765 (535) 1082 (75) 3885 (268) 613 (42) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.042 (1.07) 0.362 (0.16) N/A N/A 947 (65) N/A N/A 537 (37) 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.045 (1.14) 0.455 (0.21) 5900 (407) 873 (60) 2935 (202) 495 (34) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.050 (1.27) 0.655 (0.30) 5115 (353) 741 (51) 2650 (183) 420 (29) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.055 (1.40) 0.884 (0.40) 4550 (314) 658 (45) 2400 (165) 373 (26) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.060 (1.52) 1.140 (0.52) 4100 (283) 613 (42) 2200 (152) 347 (24) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.070 (1.78) 1.750 (0.79) 3365 (232) 545 (38) 1910 (132) 309 (21) 21/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.080 (2.03) 2.480 (1.12) 3215 (222) 504 (35) N/A N/A 285 (20) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.090 (2.29) 3.330 (1.51) 2865 (198) 476 (33) N/A N/A 270 (19) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.100 (2.54) 4.290 (1.95) N/A N/A 455 (31) N/A N/A 258 (18) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.110 (2.79) 5.380 (2.44) 2865 (198) 440 (30) N/A N/A 249 (17) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.125 (3.18) 7.610 (3.45) 2985 (206) 404 (28) N/A N/A 229 (16) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.140 (3.56) 10.200 (4.63) 2690 (185) 376 (26) N/A N/A 213 (15) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.200 (5.08) 19.290 (8.75) 2650 (183) 406 (28) N/A N/A 230 (16) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.250 (6.35) 30.100 (13.65) N/A N/A 407 (28) N/A N/A 231 (16) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.280 (7.11) 40.400 (18.33) N/A N/A 380 (26) N/A N/A 215 (15) Note:Information and data contained in these charts,as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. ABased on actual laboratory test data provided by Copper Development Association,Inc. 'Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668 kPa). 'Based upon 150°F(65.6°C)with an allowable stress of 5100 psi(359 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 4 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com sgiti OF pi NIBCO" � AHEAD OF THE FLOW® 12, .4 pn IP b Copper Water Tube continued Vail Fire&Emer.ency Services DIMENSIONAL DATA-COPPER WATER TUBE-TYPE "M" TYPE"M" Hard Drawn Only: 20-ft.(6.1m)Straight Lengths Usage: For general purpose plumbing,heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot Pressure" Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note:Information and data contained in these charts,as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. "Based on actual laboratory test data provided by Copper Development Association,Inc. 'Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 49 www.nibco.com OCIF 1$4 Nizt_alma.. 4. Zti 13- ef $)E aquather O 500S500W 4CD7 aquatherm Lindon, i1 Fire&Emergency Services 801.805.6651p/17/16 Aquatherm Red Pipe Dimensional Data SDR 7.4 MF "(mks. wt b 1111111111111b . Y� s Wal Internal Water Pipe Diameter Thickness Diameter Capacity Weight d, in, s, in., d 1 Part No. _ Dimension(ND-OD) _ (mm) (mm) in, (mm) gal/ft. Ib./ft. 4170708 1/2" -20 mm 0.79, (20) 0.11, (2.8) 0.57, (14.4) 0.013 0.11 4170710 _ 3/4" -25 mm _ 0.98, (25) 0.14, (3.5) 0.71, (18) _ 0.024 0.17 4170712 1" -32 mm 1.26, (32) 0.173, (4.4) 0.91, (23.2) 0.034 0.27 4170714 1-1/4" -40 mm 1.57, (40) 0.22, (5.5) 1.14, (29) 0.053 _ 0.41 4170716 _ 1-1/2" - 50 mm 1.97, (50) 0.27, (6.9) 1.43, (36.2) 0.083 0.64 4170718 2" -63 mm 2.48, (63) 0.34, (8.6) 1.80, (45.8) 0.133 1.01 4170720 2-1/2" - 75 mm 2.95, (75) 0.41, (10.3) 2.14, (54.4) 0.187 1.44 4170722 3" -90 mm 3.54, (90) 0.48, (12.3) 2.57, (65.4) 0.27 2.06 4170724 3-1/2" - 110 mm 4.33, (110) 0.59, (15.1) 3.14, (79.8) 0.402 3.08 4170726 4" - 125 mm 4.92, (125) 0.67, (17.1) 3.57, (90.8) 0.521 3.96 olti OF 10 © •111111, 11,1 aquathermoj ��� Vail Fire&Emergency Services 10/17/16 RED PIPE SUBMITTAL SPECIFICATION DATASHEET 1.Product Name Polypropylene-random copolymer(PP-R)pipe and fittings for wet fire suppression system: Aquatherm Red Pipe—'/2"-8" SDR 7.4 fire suppression system. 2.Product Description Basic Use: Aquatherm Red Pipe PP-R pipe and fittings are used in pressure piping systems in residential, commercial, and industrial applications. The pipe and fittings are joined by heat fusion-welding(socket, butt, fusion outlet) and do not require any glues, solvents, solder, flux, or other materials. The resulting bond is a homogenous continuation of the PP-R material between pipe and fitting, creating a joint that is stronger than either the pipe or fitting. The piping system includes a variety of transitions fittings for connection to other piping materials. Composition and Materials: PP-R is a thermoplastic material with exceptional high-temperature and chemical resistance. The PP-R material is listed per ASTM D4101 and meets the long-term strength, pressure-rating, and high-temperature performance requirements of FM 1635. Limitations: The piping system is intended to be used in the systems described above. Other applications should be reviewed with the manufacturer to determine suitability. In general,the PP-R material has exceptional chemical resistance,but specific chemicals, applications, and operating conditions must be reviewed by Aquatherm prior to use. All plastics are susceptible to UV degradation. The piping material includes UV inhibitors which ensure it will not degrade while exposed to UV during construction. However, if the piping is installed in a location subject to UV exposure, it must be protected by use of an appropriate UV-resistant wrap or coating. 3. Technical Data Applicable Standards: FM 1635, ASTM D4101,ASTM E84, CAN/ULC S102.2,FM 1635,NFPA 13, NFPA 13R,NFPA 13D Quality Control,Listings: The Aquatherm PP-R piping systems are listed and inspected by numerous independent third-party agencies globally. In North America,the Red Pipe piping system is listed by Factory Mutual(FM), and Intertek in accordance with the applicable standards and noted in listings per FM 1635,NFPA 13,NFPA 13R,NFPA 13D;and Intertek Aquatherm Advanced® (ASTM E84 and CAN/ULC S 102.2). Construction Codes: PP-R piping is permitted to be used in concealed wet fire protection applications in the following national model codes: International Building Code(IBC),National Fire Protection Association(NFPA) 13,NFPA 13R, and NFPA 13D. 4.Approval PP-R pressure piping shall be Aquatherm, manufactured in accordance with ASTM F2389 and FM 1635, and shall be listed/approved by a Nationally Recognized Testing Laboratory(OSHA NRTL). 0:0©® ©2013 Aquatherm NA,L.C.All rights reserved. www.aquatherm.com aquatherm ilk..41r, EQUIVALENT LENGTHS OF FITTINGS (FT) IP b Socket Yz" 'A" 1" 1 ' ' 1' " 2" 2' " 3" j3121-.Q 1111:11 20mm 25mm ?2 mm 40.gm 5u mm 63mm 75mm 90mm 110 mm .w mm Socket - -- . - ices CI;I:7-, fusion 1017/16 0.5 0.7 0.9 1.1 1.4 1.7 2.1 2.5 3.0 4.2 Butt fusion Butt welded 4" 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 125 mm 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm bead SDR 7.4 1.5 1.9 2.4 3.0 3.4 SDR 11 2.2 1.7 2.1 2.7 3.4 3.8 4.3 4.8 SDR 17.6 3.0 1.9 2.3 2.9 3.7 4.1 4.7 5.2 5.8 6.5 7.3 Note:The friction loss for straight pipe includes the joint between pipe sections every 19 feet.The fabricated fittings also include the losses due to the butt fusion joints between segments and attaching the fitting to the pipe.The butt fusion bead in this table should only be included when additional shorter pipe sections are butt welded together such that there is more than one joint per standard length of pipe. Electrofusion 1/2" 'A" 1" 1 4" 1 ' " 2" 21/z" 3" 3' " 4" 20 mm 25mm 1 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm coupling Socket g fusion 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" yill 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm _� SDR 7.4 0.5 0.5 0.5 I� SDR 11 0.5 0.5 0.5 - - - - - - - SDR 17.6 0.5 0.5 0.5 - - - - - - Bushing Socket '/z 3�" 1" 1'/4" 1 Y" 2" 2Y" 3" 3Y" 4" 2U mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (by 1 dimension) fusion 0.9 1.1 1.4 1.7 2.2 2.8 3.3 3.9 4.8 6.7 4 Butt welded 6" 8"" 10" 12" 14" 16" 18" 20" 22" 24" ,'f' 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm �1�, SDR 7.4 7.6 9.5 11.9 15.0 16.9 `- _ SDR 11 8.6 10.7 13.4 16.9 19.1 21.5 24.2 - - - SDR 17.6 9.3 11.6 14.5 18.3 20.7 23.3 26.2 29.1 32.6 36.7 Bushing Socket 12 'A" 1" 1 Y4" 1 Yz" 2" 2 Yz" 3" 3' " 4" 20 mm 25 mm 32 mm 40 mm 50 mm 63 mm 75mm 90 mm 11n mm 125 mm (by 2 dimensions) fusion 1.4 1.7 2.2 2.7 3.4 4.1 4.9 6.0 8.4 qi! 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" Butt welded 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm � SDR 7.4 9.5 11.9 14.9 18.8 21.1 - - - - - SDR 11 10.7 13.4 16.8 21.1 23.8 26.9 30.2 - - - SDR 17.6 11.6 14.5 18.2 22.9 25.8 29.1 32.7 36.4 40.7 45.8 Bushing Socket �„ 3A" 1" 1 ' " 1 Yz" 2" 2%" 3" 3%" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (by 3 dimensions) fusion 21 26 3-3 4.1 4.9 5-9 7.2 10.1 Butt welded 10" 12" 14" 16" 18" 20" 22" 24" 1600 mm 2000 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm A \I' SDR 7.4 11.4 14.3 17.9 22.5 25.4 - - - SDR 11 12.9 16.1 20.1 25.4 28.6 32.2 36.2 - - - SDR 17.6 14.0 17.4 21.8 27.5 31.0 34.9 39.3 43.6 48.9 55.0 328 PLANNING svm F ' ,o ilift, EQUIVALENT LENGTHS OF FITTINGS (FT) IP b Bushing Socket '/2, 3/" 1" 11/1" 1 W' 2" 2%" 3" 3%" (by4dimensions) 20mm 25mm 32mm 40mm 50mm 63mm 75mm 90mm 110 mm 125mm • ncy Services fusion 3.1 3.8 4.8 5.7 6.9 8.2' MIN 41----19 -6.-%%-- Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 160 mm 200 mm 250 mm 315 mm 355mm 400 mm 450 mm 500 mm 560 mm 630 mm SDR 7.4 13.3 16.7 20.8 26.3 29.6 a SDR 11 15.0 18.8 23.5 29.6 33.4 37.6 42.3 - - - SDR 17.6 16.3 20.3 25.4 32.1 36.1 40.7 45.8 50.9 57.0 64.1 Bushing Socket1" 1 %" 1 Y" 2" 2%z" 3" 3%z" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (by 5 dimensions) fusion as 4.4 5.5 6.6 7.9 9.6 13.4 ���� Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 160 mm 200 mm 250 mm 315 mm 355mm 400 mm 450 mm 500 mm 560 mm 630 mm SDR 7.4 15.2 19.1 23.8 30.0 33.8 as SDR 11 17.2 21.5 26.8 33.8 38.1 43.0 48.3 - - - SDR 17.6 18.6 23.3 29.1 36.6 41.3 46.5 52.4 58.2 65.2 73.3 Bushing Socket �„ N„ 1" 11A" 11/2" 2" 2Y" 3" 3Y" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (by 6 dimensions) fusion 6.2 7.4 8.9 10.8 15.1 Of Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24"i9 --„......_ 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm SDR 7.4 17.2 21.4 26.8 33.8 38.1 - - - - - SDR 11 19.3 24.2 30.2 38.1 42.9 48.4 54.4 - - - SDR 17.6 20.9 26.2 32.7 41.2 46.5 52.4 58.9 65.4 73.3 82.5 Elbow 90° Socket 1h 3/4" 1" 1 1/4" 1%2" 2" 2/s' 3" 3Y" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm fusion 1.6 2.0 2.6 3.3 4.1 5.2 6.2 7.4 9.0 12.6 Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" l 160 mm 200 mm 250 mm 315 mm 355mm 400 mm 450 mm 500 mm 560 mm 630 mm %Tv7 SDR 7.4 14.3 17.9 22.3 18.0 20.3 SDR 11 10.3 12.9 16.1 20.3 22.9 25.8 29.0 - - - SDR 17.6 11.2 14.0 17.4 22.0 24.8 27.9 31.4 34.9 39.1 44.0 Elbow 90° %2" 3/" 1" 1 %4" 1 '/2" 2" 21/2" 3" 3%2" 4" (male/female) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm Socket fusion 1.6 2.0 2.6 3.3 11) -ti 7 Elbow 45° Socket %2" 3/4" 1" 1%" 1 %2" 2" 21/2" 3" 3Y" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm fusion 0.9 1.1 1.4 1.7 2.2 2.8 3.3 3.9 4.8 6.7 Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 160 mm 200 mm 250 mm 315 mm 355mm 400 mm 450 mm 500 mm 560 mm 630 mm SDR 7.4 7.6 9.5 11.9 11.3 12.7 SDR 11 6.4 8.1 10.1 12.7 14.3 16.1 18.1 SDR 17.6 7.1) 8.7 10.9 13.7 15.5 17.5 19.6 21.8 24.4 27.5 ( =flow direction) 329 (4 °F I/4 114. ill4f. ..'1.1. EQUIVALENT LENGTHS OF FITTINGS (FT) IP to Oj ,055 Elbow 45° Yr 3i„ 1" 1 /4 rz„ 2" 21/2„ 3" s,. (male female) 20 min 25 mm 32 mm 40 mm 50 mm 63 mm 75 mm 90 mm 110 mm i 125 mm ices Socket fusion 0.9 1.1 1.4 1.7 - - - ) i,111151 ((I Tee Socket Y2" %" 1" 1%" 1 Yz" 2" 2 Yz" 3" 3 Yz" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (thru-flow) fusion 0.5 0.7 0.9 1.1 1.4 1.7 2.1 2.5 3.0 4.2 1 I � Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" �i� i 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm - - - SDR 7.4 4.8 6.0 7.4 9.4 10.6 aaa SDR 11 5.4 6.7 8.4 10.6 11.9 13.4 15.1 - - a SDR 17.6 5.8 7.3 9.1 11.5 12.9 14.5 16.4 18.2 20.4 22.9 Tee Socket Yz 3/4„ 1" 1 %'" 1 Yz" 2" 2 Yz" 3" 3 Y" 4" 20 mm 25 mm 32 mm 40 mm 50 mm 63mm 75 mm 90 mm 110 mm 125 mm (separation of flow) fusion 2.6 3.3 4.2 5.2 6.6 8.3 9.8 11.8 14.4 20.1 Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" , 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm �`� Jt SDR 7.4 22.9 28.6 35.7 45.0 50.7 as SDR 11 25.8 32.2 40.3 50.7 57.2 64.5 72.5 - - EIM SDR 17.6 27.9 34.9 43.6 55.0 62.0 69.8 78.5 87.2 97.8 110.0 Tee Socket Yz" 3/4" 1" 1 1" 1 Y" 2" 2/" 3" 3 Y" 4" 20mm 25mm 32mm 40mm 50mm 63mm 75 um 90mm 110mm 125mm (conjunction of flow) fusion 1.7 2.2 2.8 3.5 4.4 5.5 6.6 7.9 96 13.4 Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" ,�1� i 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm • #, SDR 7.4 15.2 19.1 23.8 30.0 33.8 - - - - - SDR 11 17.2 21.5 26.8 33.8 38.1 43.0 48.3 - - - SDR 17.6 18.6 23.3 29.1 36.6 41.3 46.5 52.4 58.2 65.2 73.3 Tee Socket Yz 3/a 1" 1%" 1 Yz" 2" 21/z" 3" 3'/z" 4" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (counter current in case of fusion separation of flow) 3.9 4.9 6.3 7.9 9.9 12.4 '4.8 17.7 21.7 30.2 _ Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm (Yr ' J 4 L SDR 7.4 34.3 42.9 53.6 67.5 76.1 - - - - - SDR 11 38.7 48.3 60.4 76.1 85.8 96.7 108.7 - - - SDR 17.6 41.9 52.3 65.4 82.4 93.0 104.7 117.8 130.9 146.6 164.9 Tee Socket 1/z" /" 1" 1 1A- 1 %z" 2" 2%z" 3" 3 11/2" 4" 20 mm 25 mm 32mm 40 mm 50 mm 63 mm 75 mm 90 mm 110 mm 125 mm (counter current in case of fusion conjunction of flow) 5.2 6.5 8.2 10.4 13.1 16.4 24.6 29.5 36.1 50.3 Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm c'r • J t L. SDR 7.4 57.2 71.5 89.3 112.5 126.8 - - - - - -• SDR 11 64.4 80.5 100.7 126.9 143.0 161.2 181.2 - - SDR 17.6 69.8 87.2 109.1 137.4 154.9 174.5 196.4 218.1 244.4 274.9 (I'=flow direction) 3.30 PLANNING F ' EQUIVALENT LENGTHS OF FITTINGS (FT) Alt, IP b oj Cross1" 3/4" 1" 11/4" 1%2" 2" 2%" 3" 3%z„ Socket 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 1qi,„101:1:1:1155 (separation of flow) fusion -•ncy Services 4.5 5.7 7.3 9.2 - - - - _10/17/16 - Butt welded 6" 8" 10" 12" 14" 16" 18" 20" 22" 24" J t I 160 mm 200 mm 250 mrr 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm - SDR 7.4 40.0 50.0 62.5 78.8 88.8 i.� riA, , t r SDR 11 45.1 56.4 70.5 88.8 100.1 112.9 126.8 SDR 17.6 48.8 61.0 76.3 96.2 108.4 122.2 137.5 152.7 171.1 192.4 Cross12" 3/"" 1" 1%4" 1%2" 2" 212" 3" 3%2" 4" Socket 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm (conjunction of flow) fusion 8.0 10.1 12.9 16.1 Butt welded 6" 1 8" 10" 12" 14" 16" 18" 20" 22" 24" Sbir. J g L 160 mm 200 mm 250 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm } SDR 7.4 70.5 88.1 110.2 138.8 156.4 as 4 r SDR 11 79.5 99.3 124.1 156.5 176.4 198.8 223.5 as - SDR 17.6 86.1 107.6 134.5 169.5 191.1 215.2 242.2 269.0 301.4 339.0 Fusion outlet %2" 3/" 1" 1 %" 1%2" 2" 2%" 3" 31/2" 4" 6" 8" 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm 160 mm 200 mm (separation of flow)3 Side-wall fusion � J # L (based on 0.6 0.8 1.0 1.3 1.7 2.1 2.5 3.0 3.6 5.0 5.8 6.5 �'1 branch size) Transition 1/2" 3/4" 1" 1 1r 1'/2" 2" 21/2" 3" 3' " 4" (female thread) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm Socket fusion 1.1 1.4 1.7 2.2 2.7 3.4 4.1 11.1 (*=Now direction) a Note: For reducing tees,add the "thru-flow"value in the main line to the configuration value in the branch size. For example,a 4"x 4"x 3/" reducing tee with flow separation would be 4.2 ft+3.3 ft=7.5 ft,while a conjunction of flow would be 4.2 ft+2.2 ft=6.4 ft. 3.31 ilk..41,1:, EQUIVALENT LENGTHS OF FITTINGS (FT) v. b Transition r2- ,"" 1" 1 A" 1 1/2' 2" 2r" 3" (male thread) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm ices c .4.___LL Socket10 17/16 fusion 1.5 1.9 2.4 3.1 3.8 4.8 5.7 6.9 8.4 - Elbow i2" 3A" 1" 1 %" 1 12" 2" 2%2" 3" 3%2" 4" (female thread) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125-59 IIII���� Socket fusion 1.9 2.4 3.0IIII __0 Elbow 12" 3/a" 1" 1 %" 1 1/2" 2" 2%2" 3" 31/2" 4" (male thread) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm Socket Or—c fusion 2.2 2.7 3.5 tI— Tee %2" 3/4" 1" 1 %" 1%" 2" 2%2" 3" 3%2" 4" (female thread) 20 mm 25mm 32mm 40 mm 50 mm 63mm 75mm 90 mm 110 mm 125 mm _ Socket _V L fusion 3.5 4.4 5.6 Tee 1/2^ 3/4„ 1" 111" 1 ' " 2" 2%" 3" 3%2" 4" Image thready 20 mm 25mm 32 m 15 4 m 63mm 75 nm °0 la, 110 mm 125 mm Socket i ,9 ' fusion /, " 3.9 IIII 3.32 3/10/2016 Aquatherm and Hanger Spacing IF S 4 ett :.f LOGIN REGISTER aquaIherI Documents Find Local Support Web Tools ��� state of the pipe Vail Fire&Emergency Services 10/17/16 HOME READ SEE MANAGE about Aquatherm Aquatherm in action my Aquatherm resources LEARN INSTALL DESIGN about Aquatherm Aquatherm systems with Aquatherm AAA You are here: Home Install Technical Bulletins Aquatherm and Hanger Spacing Friday,14 September 2012 13:35 AQUATHERM ANI1 HANGER SPACING New Construction Pipes typically are found in groups of various size pipes run side by side. This can ease installation by allowing multiple pipes to rest on a single trapeze pipe support. But every differing pipe size has different support spacing, complicating this approach.Aquatherm has developed a simple cost effective solution for hanging pipes. We determined that two trapeze hangers per pipe would make installation simple,while avoiding unnecessary hangers.This means a trapeze every 6.5 feet(2 meters). In order to allow our smaller diameter pipes to span the extra distance beyond the recommended spacing,we recommend using pipe supports such as manufactured by Raywal BISMAT 5000. By installing the appropriate sized Pipe Support at each trapeze, all size pipes with any water temperature can be supported every 6.5 feet. Aquatherm Recommended Unsupported Pipe Length Polypropylene hanger spacing (new construction) Re-piping Projects On projects where copper pipe is being replaced, it is usually desirable to reuse the existing pipe supports. The difference in recommended hanger spacing between copper and Aquatherm makes this difficult. By using the Pipe Supports, the recommended spacing for Aquatherm Piping Systems can equal or exceed the http://www.aquatherm.com/aquatherm-and-hanger-spacing 1/3 3/10/2016 Aquatherm and Hanger Spacing VI OF recommended copper spacing as illustrated on the next page. � Z Aquatherm Recommended Unsupported Pipe Length Is If alb--NO # b ....._Polypropylene hanger spacing (retrofit) Vail Fire&Emergency Services 10/17/16 The table below gives the Length of each size of Pipe Support for each pipe diameter along with the resulting Minimum Hanger Spacing.Also in the table is the Typical Hanger Spacing allowed for Copper Tube. Pipe Supports Nominal Pipe Diameter Support Length Minimum Hanger Typical Spacing (inches) (inches) Spacing (ft) for Copper (ft) 1/2 30 6.5 5 3/4 30 6.5 5 1 30 6.5 6 1 1/4 36 7 8 1 1/2 48 8 8 2 36 8 8 2 1/2 48 9 9 3 60 10 10 31/2 24 10.5 11 4 24 11.5 12 6 36 12.75 14 8 N/A 11.3 16 On domestic hot water piping the pipe support should be coated with a rubberized spray coating or some other method to prevent bare metal contact with Aquatherm piping. http://www.aquatherm.com/aquatherm-and-hanger-spacing 2/3 40101 fr„ 3/10/2016 Aquatherm and Hanger Spacing r p F PDF Version: 201209A-AOTTB-Aquatherm-and-Hanger-Spacing.pdf � off # Vail Fire&Emergency Services 10/17/16 (801) 805-6657 I 500 S 500 W, Bldg. 1 I Lindon, Utah 84042 Get Support I Terms of Use Copyright © 2016. Aquatherm Polypropylene Pipe. http://www.aquatherm.com/aquatherm-and-hanger-spacing 3/3 sviti OF go NIBCO" wv i; � AHEAD OF THE FLOW® Z 4. ml r'71 CAPS COUPLINGS154. 6 APPRO -Igo]'a 41011 i NOM.SIZE NET WT./LBS. irv�FIES ices 0119 - - :::11211 Es 3 x 21/2 1�IIg/16 /2 3 x 2 1.06 15/16 \-. n---.� 14- 3 x 1 1/2 0.92 11/32 --4--N 31/2 x 3 1.52 1/2 4x31/2 2.12 19/32 600 4 x 3 1.92 27/32 617 Reducing Coupling C x C-Wrot 4x21/2 1.77 1 Tube Cap C-Wrot APPROX. DIM.A 4x2 1.92 11/4 APPROX. DIM.N NOM.SIZE NET WT./LBS. INCHES 5 x 4 3.50 331/32 NOM.SIZE NET WT./LBS. INCHES 1/8 x 3/16 O.D. 0.01 5/32 5 x 3 3.18 115/32 1/8 0.01 1/32 5/16 0.D.x 1/8 0.01 3/16 5 x 21/2 3.50 13/16 1/4 0.01 3/32 1/4 x 5/16 0.D. 0.01 3/16 5 x 2 3.09 21/32 3/8 0.01 3/32 1/4 x 1/8 0.01 3/16 6 x 5 5.70 11/8 1/2 0.02 3/32 3/8x1/4 0.02 3/16 6 x 4 5.24 11/2 5/8 0.03 1/6 3/8 x 5/16 0.D. 0.01 1/4 6 x 3 5.04 2 3/4 0.04 1/8 3/8 x 1/8 0.01 1/4 6 x 21/2 5.13 21/4 1 0.07 5/32 1/2x3/8 0.03 3/16 6 x 2 4.89 21/2 1 1/4 0.10 3/32 1/2x1/4 0.02 1/4 8 x 6 13.06 119/32 1 1/2 0.16 1/8 1/2 x 1/8 0.03 11/32 8 x 4 12.22 219/32 2 0.27 5/32 5/8 x 1/2 0.05 3/16 8 x 3 11.79 33/32 21/2 0.50 7/32 5/8 x 3/8 0.04 11/32 8 x 21/2 12.64 33/8 3 0.78 7/32 5/8 x 1/4 0.03 13/32 4 1.66 1/4 3/4 x 5/8 0.07 3/16 3/4 x 1/2 0.06 9/32 1/11191-..- . ,-- 3/4 x 3/8 0.06 3/e 3/4x1/4 0.05 11/32 1 x 3/4 0.11 11/32 1 x 5/8 0.09 3/2 n N 1 x 1/2 0.10 11/32 600-RS 1 x 3/8 0.10 13/32 717 11/4x1 0.16 5/16 Coupling with Rolled Tube Stop 1 1/4x3/4 0.18 17/32 C X C -Wrot Tube Cap C - Cast 1 1/4x5/8 0.18 5/6 APPROX. DIM.A APPROX. DIM.N 1 1/4 x 1/2 0.14 7/16 NOM.SIZE NET WT./LBS. INCHES NOM.SIZE NET WT./LBS. INCHES 1/2 x 1 1/4 0.23 5/16 1/8 O.D. 0.01 1/16 5 5.48 7/16 1 1/2 x 1 0.22 9/16 3/16 0.D. 0.01 3/32 6 9.07 17/32 1 1/2x3/4 0.20 3/8 1/8 0.01 1/16 1 1/2 x 1/2 0.19 1/2 5/16 0.D. 0.01 3/32 .11 D- 2 x 1 1/2 0.41 9/16 1/4 0.01 1/16 2 x 1 1/4 0.35 11/16 3/8 0.01 3/32 2 x 1 0.37 7/16 1/2 0.03 3/32 2 x 3/4 0.34 17/32 5/8 0.04 3/32 A ~' 2 x 1/2 0.35 23/32 3/4 0.06 3/32 21/2 x 2 0.59 9/16 7/8 0.09 3/32 21/2x11/2 0.65 11/16 1 0.11 3/32 717 D 21/2x11/4 0.65 13/16 11/4 0.16 1/8 Drain Cap - Cast 21/2x1 0.73 29/32 1 1/2 0.23 1/6 APPROX. DIM.A 2 0.41 1/8 NOM.SIZE NET WT./LBS. INCHES Continues... 21/2 0.65 1/8 1/2 0.06 21/32 3 0.93 1/8 31/2 1.45 5/32 4 1.93 7/32 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 9 www.nibco.com NIBCO AHEAD OF THE FLO ° � W *n IS ir COUPLINGS continued # vino Vail. ncy Services 10/ 7/16 A f g 1 4-.-A 600-DS 601 701-D Coupling with Dimpled Tube Stop Coupling without Stop Drain Coupling C x C - Cast C x C -Wrot C x C -Wrot APPROX. DIM.A NOM.SIZE NET WT./LBS. INCHES APPROX. DIM.A APPROX. DIM.B NOM.SIZE NET WT./LBS. INCHES NOM.SIZE NET WT./LBS. INCHES 1/2 0.08 1/4 3/16 0.D. 0.01 3/32 1/4 0.01 11/16 3/4 0.14 1/4 1/8 0.01 1/16 3/8 0.01 27/32 1 0.22 1/4 5/16 O.D. 0.01 3/32 1/2 0.03 1 1/4 0.01 1/16 5/8 0.04 111/32 3/8 0.01 3/32 3/4 0.06 119/32 1/2 0.03 3/32 1 0.11 129/32 5/8 0.04 3/32 11/4 0.16 21/16 3/4 0.06 3/32 1 1/2 0.23 25/16iiip A 1'- 7/8 0.09 3/32 2 0.41 213/16 1 0.11 3/32 21/2 0.64 215/16 11/4 0.16 1/8 3 0.86 35/16 702 1 1/2 0.23 1/8 31/2 1.40 313/16 Eccentric Coupling C x C-Cast 2 0.41 1/8 4 1.84 45/16 21/2 0.65 1/8 5 3.50 55/16APPROX. DIM.A NOM.SIZE NET WT./LBS. INCHES 3 0.93 1/8 6 5.60 63/16 3/4x1/2 0.10 17/32 31/2 1.45 5/32 8 13.68 83/32 1x3/4 0.18 1/4 4 1.93 7/32 1 1/4 x 1 0.25 1/4 5 3.53 7/32 1 1/4x3/4 0.24 9/32 6 5.63 7/32 8 14.12 15/32 NM 16 A '1 1 - D 701 to, Reducing Coupling C x C - Cast APPROX. DIM.A 724-5-A NOM.SIZE NET WT./LBS. INCHES 3x11/4 1.35 23/32 Hy-Set Hanger Coupling 3 x 1 1.64 27/32 C - Cast APPROX. DIM.C DIM.D NOM.SIZE NET WT./LBS. INCHES INCHES 1/2 0.05 15/8 23/32 3/4 0.09 15/8 27/32 1 0.13 15/8 1 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 10 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NIBCO" wv, .4..53 /e AHEAD OF THE FLOW® pn COUPLINGS continued CROSSES ELBOWS A410 Vail Fire: mergency Services 10117/ 7 lla c r SAM 606 1aM _ j A _ _ 45° Elbow C x C -Wrot 1 MI A I � IAPPROX. DIM.C DIM.D NOM.SIZE NET WT../BS. INCHES INCHES I -.-A-.-- A-.-1 1 1/8 0.01 1/4 1/4 736 1/4 0.02 9/32 9/32 Cross-Over Coupling _.._ A 3/8 0.03 3/16 3/16 C X C - Cast 735 n 1/2 0.04 9/32 9/32 5/8 0.09 15/32 15/32 APPROX. DIM.A NOM.SIZE NET WT./LBS. INCHES Cross C x C x C x C - Cast 3/4 0.10 11/32 11/32 1/2 0.27 17/16 APPROX. DIM.A 7/8 0.20 11/16 11/16 NOM.SIZE NET WT./LBS. INCHES 1 0.16 3/8 3/8 3/4 0.60 129/32 3/8 0.09 3/8 11/4 0.25 17/32 17/32 1/2 0.15 7/16 1 1/2 0.35 19/32 19/32 3/4 0.30 9/16 2 0.65 25/32 25/32 1 0.54 23/32 2 1/2 1.07 29/32 29/32 11/4 0.78 7/8 3 1.58 11/8 11/8 1 1/2 1.05 1 4 3.35 17/16 17/16 2 2.00 11/4 5 11.05 19/16 19/16 21/2 2.96 11/2 6 16.95 2 2 8 23.00 29/32 29/32 1401 c NNIM e-+-I 606-2 45° Fitting Elbow Ftg x C -Wrot APPROX. DIM.B DIM.C NOM.SIZE NET WT./LBS. INCHES INCHES 1/4 0.02 9/16 1/4 1/2 0.04 3/4 7/32 5/8 0.08 11/8 13/32 3/4 0.10 11/16 5/16 1 0.16 17/32 15/32 1 1/4 0.25 119/32 17/32 1 1/2 0.35 125/32 19/32 2 0.65 23/16 25/32 2 1/2 1.07 23/16 29/32 3 1.55 219/32 15/32 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 m TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NIBCO AHEAD OF THE FLOW® 1tem, OF� 4.c r74 IS ir Igle' Ni ELBOWS continued #,� IQQ ‘ziVai mergency Services r 10l�� - 111(lai c411111: IIII. ilh B� c ‘II I. Li-o4 706-2 707 607-LT 45° Fitting Elbow Ftg x C - Cast 90°Elbow- Close Rough 90° Elbow- Long Radius APPROX. DIM.B DIM.C C x C - Cast C x C -Wrot NOM.SIZE NET WT./LBS. INCHES INCHES APPROX. DIM.C DIM.D APPROX. DIM.C DIM.D 4 4.31 311/32 15/16 NOM.SIZE NET WT./LBS. INCHES INCHES NOM.SIZE NET WT./LBS. INCHES INCHES 1 1/4 x 1 0.42 15/s 115/32 3/16 0.D. 0.01 13/32 13/32 1 1/4 x 3/4 0.34 9/16 13/16 1/8 0.01 13/32 13/32 MP 1 1/4x1/2 0.28 15/32 27/32 5/16 0.D. 0.02 9/16 9/16 ic till= 1 1/2 x 1 0.54 11/16 1 1/4 0.02 17/32 17/32 1 1/2x3/4 0.42 19/32 31/32 1/4x 1/8 0.01 19/32 1/2 (...-4 M 1 1/2 x 1/2 0.40 5/6 29/32 3/8 0.04 23/32 23/32 2 x 1 1/4 0.86 7/8 11/4 1/2 0.08 7/8 7/8 0 2 x 1 0.78 3/4 11/4 1/2 x 3/8 0.06 13/16 13/16 2x3/4 0.69 5/8 11/4 1/2 x 1/4 0.03 25/32 21/32 607 2 1/2 x 2 2.16 13/16 19/32 5/8 0.10 13/32 13/32 90° Elbow- Close Rough 3x21/2 2.26 111/16 11/2 5/8x1/2 0.09 11/16 11/16 C x C -Wrot 3 x 2 2.68 13/8 19/16 3/4 0.16 11/8 11/8 APPROX. DIM.C DIM.D 4 x 3 5.18 129/32 215/32 3/4 x 5/8 0.13 11/4 13/32 NOM.SIZE NET WT./LBS. INCHES INCHES 3/4 x 1/2 0.10 11/8 11/16 1/8 0.01 13/32 13/32 7/8 0.28 119/32 119/32 1/4 0.02 9/32 9/32f I I „ 1 0.28 17/16 17/16 3/8 0.03 1/2 1/2 1 x 3/4 0.20 11/4 11/8 1/2 0.04 3/8 3/8 1 I- 1 x 5/8 0.15 113/32 13/32 1/2 x 3/8 0.04 9/16 21/32 • 01 -I I- 1 1/4 0.42 17/8 17/8 3/4 0.10 17/32 17/32 0 1 1/4 x 1 0.33 125/32 11/2 3/4 x 5/8 0.12 29/32 7/8 1 1/2 0.66 21/4 21/4 3/4 x 1/2 0.10 17/32 3/4 2 1.23 215/16 215/16 1 0.21 23/32 23/32 607-I 21/2 1.96 311/16 311/16 1 x3/4 0.16 23/32 5/8 90° Elbow- 3 2.93 41/32 41/32 1 1/4 0.31 11/32 11/32 Intermediate Radius C x C 4 5.95 51/4 51/4 1 1/4x 1 0.31 15/8 115/32 -Wrot 1 1/2 0.46 17/32 17/32 APPROX. DIM.C DIM.D 1 1/2 x 1 1/4 0.35 15/32 13/32 NOM.SIZE NET WT./LBS. INCHES INCHES 2 0.84 11/2 11/2 1/2 0.06 19/32 19/32 2 x 1 1/2 0.58 17/16 11/4 5/8 0.09 7/8 7/8 21/2 1.41 127/32 127/32 3/4 0.14 13/16 3/16 3 2.07 23/32 23/32 1 0.24 11/16 11/16 31/2 2.94 23/8 23/8 4 4.23 225/32 225/32 5 7.74 27/8 27/8 6 10.95 37/16 37/16 8 29.50 423/32 423/32 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com ..16 lti CIF pi NIBCO" � AHEAD OF THE FLOW° pn ELBOWS continued 3 i qoJ% OOPt V rgency Services II1 I wo 10 7l1 B 8-- • Li g-N- . B----m- 607-2 607-2-LT 90°Fitting Elbow-Close Rough 90°Fitting Elbow- Long Radius 607-2-2-LT Ftg x C -Wrot Ftg x C -Wrot 90°Fitting Elbow- Long Radius APPROX. DIM.B DIM.C APPROX. DIM.B DIM.C Ftg x Ftg -Wrot NOM.SIZE NET WT./LBS. INCHES INCHES NOM.SIZE NET WT./LBS. INCHES INCHES APPR1/4 0.02 3/4 3/8 1/8 0.01 13/32 1/2 NOM.SIZE NET WT./BS . INCHES 3/8 0.03 15/16 1/2 1/4 0.02 11/8 3/4 1/4 0.02 27/32 1/2 0.04 31/32 3/8 3/8 0.05 11/8 7/8 3/8 0.04 11/8 5/8 0.07 17/32 17/32 1/2 0.08 19/16 13/32 1/2 0.08 119/32 3/4 0.10 111/32 17/32 1/2 x 3/8 0.06 15/16 13/16 5/8 0.10 111/16 1 0.20 13/4 27/32 1/2x1/4 0.03 11/4 5/8 3/4 0.16 115/16 11/4 0.33 21/8 11/32 5/8 0.10 125/32 13/32 1 0.31 21/2 1 1/2 0.46 213/32 17/32 3/4 0.16 115/16 11/8 1 1/4 0.43 229/32 2 0.84 227/32 11/2 1 0.31 21/2 121/32 11/2 0.65 37/16 21/2 1.39 315/32 129/32 11/4 0.43 229/32 17/8 2 1.25 411/32 3 2.10 313/16 23/32 11/2 0.66 213/32 21/4 4 4.00 43/4 225/32 1 1/2 x 1 1/4 0.50 33/8 23/32 2 1.27 411/357/32 231/32 ll 21/2 2.16 57/32 311/16 3 3.10 53/4 41/32 -cft=7 7 4/0 B 49111111111:1111 19 s B -F-1 Lit 1111= 707-2-4 607-21 B,1 90°Fitting Elbow 90°Fitting Elbow- Ftg x M - Cast Intermediate Radius 607-2-2 APPROX. DIM.B DIM.E NOM.SIZE NET WT./LBS. INCHES INCHES Ftg x C -Wrot 90°Fitting Elbow-Close Rough 1/2 0.12 7/8 25/32 APPROX. DIM.B DIM.C Ftg x Ftg - Wrot NOM.SIZE NET WT./LBS. INCHES INCHES APPROX. B 1/2 0.06 15/32 19/32 NOM.SIZE NET WT../BS. NIH S 5/8 0.09 19/16 7/8 1/2 0.04 11/16 3/4 0.14 15/8 13/16 3/4 0.12 115/32 1 0.24 21/32 11/16 1 0.20 123/32 11/4 0.33 21/8 1 1/2 0.46 213/32 2 0.82 227/32 3 2.12 37/8 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 II www.nibco.com to OF iv. ZURN® Model ZW209FP � WILKINS Fire Protection Pressure Reducing Valve SI' IITI ir lOw IN, Application _• _ AY__ 0,, #11 The Zurn Wilkins Model ZW209FP Pilot Operated Pressure =l` � ReducingValve is designed specifically for Fire Suppression a - 9 P Y pp +' - mergency Services Systems to reduce high inlet pressures to a safe and stable • I , outlet pressure.The pilot assembly reacts to changes in 1111 ' downstream pressure allowing the main valve to modulate - F between the closed and open position ensuring a constant T}. - t.' downstream set pressure. Once the downstream pres o�� ofF�" sure reaches the pilot setting,the main valve will seal shut DIRECTION OF FLOW o-c\oN preventing damage downstream. Pressure regulation is not o\R� dependent upon flow rate, resulting in minimal pressure loss Options through the valve. In addition the Model ZW209FP comes (Add suffix letters to ZW209FP) standard with red epoxy coating internally and externally for Function corrosion protection,as well as isolation valves and pressure ❑ C - 40XL Hydraulic Check gauges for quick and easy maintenance or repair. The Zurn Body Wilkins Model ZW209FP is available in both globe and angle ❑ A - Angle Style Body pattern bodies. Connections ❑ G - Grooved Ends(inlet rating 300 psi) ❑ TH - NPT threaded (inlet rating 300 psi) Approvals ❑ Y - ANSI Class 300 Flanged (inlet rating 300 psi) • UL and C-UL Listed (1-1/4"thru 10") ❑ X - ANSI Class 150 Flanged (inlet rating 250 psi) Pilot System ❑ RV - Pilot on Reverse Side C CO US LISTED Schematic Diagram Item Description of Standard Features Materials 1 Main Valve Main Valve Body Ductile Iron ASTM A536 2 SXL"Wye"Type Strainer Main Valve Cover Ductile Iron ASTM A536 3 Pressure Gauge Disc Guide Stainless Steel 4 Restriction Fitting Seat Stainless Steel 5 PV-PRD Pressure Reducing Control Disc Buna-N Rubber C 40XL Hydraulic Check Diaphragm Nylon Reinforced Buna-N Stem Stainless Steel Model ZW209FPG Spring Stainless Steel C 4 5 III N Standard Features ❑ "Wye"Type Strainer ❑ Inlet and Outlet Pressure Gauges(UUFM) ❑ 3-Way Gauge Isolation Valves lity ❑ Red Epoxy Coated, FDA Approved 3 Nil 3 ❑ Copper Tubing and Brass Fittings 0 Sizes 44.000„ D G Globe and Angle Style Body: , Flanged ends ❑ 1 1/2" thru 10" FLOW Grooved ends ❑ 1 1/2" thru 10" Threaded ends ❑ 1 1/4" thru 3" Temperature Rating: ❑ Water 33°F to 140°F Standards And Pressure Ratings Pilot Spring Range: ❑ 50-165 psi Residual Pressure(155 psi Max 10") Standards Compliance UL Pressure Ratings Main Body ANSI/AWWAC530 Flanged CLASS 150-ANSI B16.42 250 psi CLASS 300-ANSI B16.42 300 psi Refer to www.zurn.com for updated information. Grooved IPS-AWWA C606 300 psi Threaded NPT-ANSI B1.20.1 300 psi Zurn Industries,LLC I Wilkins Rev.H 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 Date:3/16 In Canada I Zurn Industries Limited Document No.ACV-ZW209FP 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 Product No.Model ZW209FP www.zurn.com Page 1 of 3 Globe and Angle Main Valve Dimensions IF DIM FULL PORT VALVE SIZE INCHES(mm) iti41(4 CI/4 .ii 11/4(32) 1 1/2(38) 2(50) 21/2(65) 3(80) 4(100) 6(150) 8(200) 10(250) itC Threaded 7 1/4 7 1/4 9 7/16 B A Class 150 Flange 8 1/2 9 3/8 11 12 15 20 25 3/8 29 3/4 +Y, Class 300 Flange 9 10 11 5/8 13 1/4 15 5/8 21 26 7/16 31 1/8 ■ }5 Grooved 8 1/2 9 11 12 1/2 15 20 25 3/8 29 3/4 C ,-iIO]. B Diameter 5 5/8 5 5/8 6 3/4 8 9 3/16 11 11/16 15 3/4 20 1/8 2311/16 I Vtri. C Max. 5 3/4 5 3/4 6 3/16 7 3/8 8 10 3/16 12 5/16 15 9/16 17 5/8 p /ail ergency Services Threaded/Grooved 1 3/8 1 3/8 1 3/4 2 1/8 2 9/16 3 7/16 5 5 5 13/16 10/17 D Class 150 Flange 2 1/2 3 3 1/2 3 3/4 4 1/2 5 1/2 6 3/4 8 �E Class 300 Flange 3 3 1/4 3 3/4 4 1/8 5 6 1/4 7 1/2 8 3/4 A E NPT Body Tap 3/8 3/8 3/8 1/2 1/2 3/4 3/4 1 1 Globe Style Body F NPT Cyr.Plug Tap 1/2 1/2 1/2 1/2 _ 1/2 3/4 3/4 1 1 - G NPT Cover Tap 3/8 3/8 3/8 1/2 1/2 3/4 3/4 1 1 B Threaded 3 1/4 3 1/4 4 3/4 5 1/2 6 1/4 F H Class 150 Flange 4 4 3/4 5 1/2 6 7 1/2 10 12 11/16 14 7/8 G Nip. Class 300 Flange 4 1/4 5 6 6 7/16 8 10 1/2 13 1/4 15 9/16 C Grooved 4 7/16 4 3/4 5 1/2 6 7 1/2 _10 12 11/16 14 7/8 Threaded 115/16 115/16 31/4 4 41/2 Class 150 Flange 4 3 1/4 4 4 5 6 8 8 5/8 n J J Class 300 Flange 4 1/4 3 1/2 4 5/16 4 7/16 5 1/6 6 1/2 8 1/2 9 5/16 I—H- Grooved 3 3/16 3 1/4 4 4 1/4 5 6 8 8 5/8 Valve Stem Internal Thread 10-32 10-32 10-32 10-32 1/4-20 1/4-20 1/4-20 3/8-16 3/8-16 Angle Style Body Stem Travel(in) 7/16 7/16 3/4 7/8 1 1 3/16 1 3/4 2 3/8 2 13/16 Approx.Wt.(lbs) 22 26 36 55 70 130 240 440 720 �' )+ 1 Pilot System Dimensions a o I fl II til 0 0 PILOT SYSTEM DIMENSIONS VALVE SIZE INCHES(mm) 0 INLET o®�G� -i- �j'� O DIM 1-1/4 1-1/2 2" 2-1/2" 3" 4" 6" 8" 10" - c.:! .1. ,�1- IZ (32) (40) (50) (65) (80) (100) (150) (200) (250) �. X Max.(inches) 8 1/2 8 1/2 8 1/2 8 1/2 9 1/2 12 13 14 15 3/4 Globe Pilot System Dimensions Full Port Y Max.(inches) 4 4 3 1/2 4 41/2 6 8 10 12 .` �, Body — I���� X Z Max.(inches) 81/2 81/2 9 9 91/2 10 11 1/2 13 14 1/2 „le W Max.(inches) 71/2 71/2 71/2 71/2 71/2 71/2 10 13 15 •�F7�/) �`�Ia„j�"• •Angle " j X Max.(inches) 81/2 81/2 8 1/2 8 1/2 9 1/2 12 13 14 17 1/2 �:�l,1 � Z Y-1--W Body Y Max.(inches) 5 5 5 5 5 5 13/16 7 7/8 10 12 INLET Z Max.(inches) 9 9 9 1/2 9 1/2 10 10 1/2 12 13 1/2 15 Angle Pilot System Dimensions Flow Characteristics BODY MINIMUM FRICTION LOSS PRESSURE REDUCTION LIMIT 100 pppMIE::: ==E::: --==-- 300 UL Limit Damage Zone Noise Limit mmm�IIiiii �. MES:iii A , ' mNIENNE ^ m N • �m: Cavitation damage /:-- ----U..p p 8 g° &• ,,sv° m •ne(intern itient .r,�... M=M■■MOil O°' .S" -_,..6f �¢ o 4—:J,m e—G°� 250 Am .peration allowed) __■■■II,W/,� ry ry /.� P A.er,. , . Cl) /„ ti I I I — Do not operate �.=..... a -.,11."ii I I .//'ll�E� //'I,- a inthis area L.r Noise mm.amm====mm a 10 200 red zone �.I i O MW(MgI/iii i 7m,,ZE2iiiiv ZAVAri igi w i:C -- zone w• M=MEMIi1MI11%//I%IVAMEMP%7N//II/AFAMI11co 150 AM��MM• MMMM=MMM�MMMM MI,I■11.1////.I■■►GIII/%/II■11111� r �m�mm•.mmmSafe N M ' '—.----- /1150 /AIPOIWAI%IIIIIM 0 A N A Al operating zone • 1 - oa -- o0 ov —o� -- J 100 m imi�===========.====== a �' :=-111�II,.MM'A lI f IA Al::::i A A /II/II►IL/./5W../ANAI/iAI/M7 =.MEN.N III w/ANNwI.I,/.I2II�I/./I/IiIII//,'MM■■NI11N 50 I/II/%%R11r/M,MKg .AI'AI/IM■■■■111M ii........................ o 10 100 1000 10000 0 20 40 60 80 100 120 FLOW(GPM) OUTLET PRESSURE(PSI) See Instruction Sheet at www.zurn.com for more setting information. * Notes for Body Minimum Friction Loss Chart: Minimum inlet pressure is 10 psi higher than set point or the additional body friction loss at intended flow,whichever is higher. (friction loss may be important at flows above 20 ft/s) Example:A 6"valve intended to flow 2000 GPM at 150 psi has a friction loss of 20 psi at 2000 GPM.The minimum inlet pres- sure would be 150+20= 170 psi.When inlet pressure is below set point,the outlet pressure will be the pressure at the inlet minus the friction loss. Zurn Industries,LLC I Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1 L2 Ph.905-405-8272,Fax 905-405-1292 www.zurn.com Page 2 of 3 414 OF Flow calculations are based o , NPS(inches) 1 1/4 1 112 2 2 1/2 3 4 6 8 10 schedule 40 Pipe. Maximum • {� Valve Size is approximately. M DN (mm) 32 38 50 65 80 100 150 200 250 20 ft./sec(6.1 meters/sec). Maximum intermittent flow is . +�, Min Flow Rate to set Valve(GPM) 15 15 100 35 60 100 220 400 600 (7.6 meters/sec). O Minimum continuous flow is app .".-11:101.114 Max Flow Rate(GPM) 125 160 250 375 600 1000 2250 4000 6000 1.25 ft./sec(0.4 meters/sec). Vail Fire&Emergency Services 10/17/16 Operation The Model ZW209FP utilizes a pressure reducing pilot valve that installs on the discharge side of the control circuitry.The pi- lot is a direct acting, normally open, spring loaded,diaphragm actuated valve.The operation of the ZW209FP begins with ac- curately sizing the valve,then fine tuning the control circuit by adjusting the pilot spring to the desired downstream pressure. Inlet pressure is piped to the inlet port of the pressure reducing pilot.A sensing line runs internally from the discharge side of the pilot to its lower control chamber under the diaphragm.Thus, downstream pressure exceeding the preset acts to close the pilot while the adjustable spring seeks to keep it open.The result is a modulating action in the pilot that is transmitted to the cover of the main valve.This creates a mirror modulation of the diaphragm assembly in the main valve. Downstream pres- sure is maintained within narrow limits regardless of changing flow rates or varying inlet pressures. Typical Installation The upstream and downstream pressure gauges are required by Underwriters Laboratories®(UL).Also a relief valve of not less than 1/2" in size MUST be installed on the downstream side of the pressure control valve.Adequate drainage for the relief valve discharge must be provided. UI Installation Specification Requirements UL installation specifications require the valve to be installed in accordance with the standard for installation of sprinkler systems, NFPA 13, or the standard for installation of standpipes and hose systems, NFPA 14.The valve is to be inspected, tested and maintained in accordance with the standard for the Inspection,Testing and Maintenance of Water-Based Fire Protection Systems, NFPA 25. Typical Installation JCLu *jai( 0 Vllttr4f v.0\1\14) CkREG�10N 0 • Specifications The Pressure Reducing Valve shall be a diaphragm actuated, pilot controlled.The main valve body shall be Ductile Iron ASTM A 536.The stem of the basic valve shall be guided top and bottom.The diaphragm shall not be used as a seating surface. All internal and external ferrous surfaces shall be coated with a high quality,fusion epoxy coating. The pilot control shall con- sist of a two-way, normally open, direct acting,adjustable spring loaded,diaphragm actuated pressure reducing pilot.The pilot control shall be field adjustable from 50 psi to 165 psi.The Pressure Reducing Valve shall be a ZURN WILKINS Model ZW209FP. Job Name Contractor Job Location Engineer Zurn Industries,LLC I Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 www.zurn.com Page 3 of 3 sglti wit. OF go NIBCD® .7 AHEAD OF THE FLOW'" wW�/ � ..., 300 lb. WWP Bronze Ball Valves De 0 Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1" - 2" • Re ��� Standard Port Design 21/2" • Accepts Internal Supervisory Switches* Vail Fire&Emergency Services •10/1 16 300 PSI/20.7 Bar Non-Shock Cold Water -4„\-- CONFORMS TO MSS SP-110 • FMRC APPROVED • 111 ' UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 ,-,. - APPROVED BY NEW YORK CITY M.E.A. 218-04-E WHEN 'ty`,- 4� t ASSEMBLED WITH APPROPRIATE NYC INDICATOR FLAG. KT-505-W-8* MATERIAL LIST '''44-14010. OP Threaded PART SPECIFICATION 1. Body Bronze ASTM B 584 Alloy C84400 2. Ball Chrome Plated Brass ASTM B 124 Alloy C37700 3. Seat Ring Carbon-filled TFE KG-505-W-8* 4. Thrust Washer Reinforced TFE Grooved 5. Stem Bronze ASTM B 371 Alloy C69430 m 6. Stem 0-Ring Nitrile 0 e6 7. Retaining Washer Brass 8. Retaining Ring Steel 0 9. Ground Wire Screw Steel 0 10;I 10. 505-8 Act Assy. Brass © p.N~;., fl) 11. Body End Bronze ASTM B 584 Alloy C84400 0 'rm - 12. Mounting Screw Steel 0 II1!!!JI1Ii1 13. Lock Washer Steel 14. Handle Pin Brass , ' I 15. Hand Wheel Steel/plastisol coated(11/4"-2'/") B Brass Tee Handle(1") 'A' 16. Indicator Flag Painted Steel ®0 17. Body Gasket Elastomer 18. Lead Screw 0-Ring Nitrilea1; Y 1100:4 q=n.1a 19. Thrust Washer Anti-friction Polymer > y, �\� � � 20. Cover Gasket Neoprene --1,=��li`pinit�7�'��j P - Went Went am' ' . 21. Flag Seal 0-Ring Nitrile E . o rP 22. Tamper-Proof Screw Stainless Stee <----, ' 23. Pipe Plug(-4 units) Stainless Steel(Not shown) ©m m*-4 version has no factory mounted internal supervisory switches. ® 13 Refer to page 41 for details for TS-2M Switch Kit. KT-505W DIMENSIONS-WEIGHTS-QUANTITIES Dimensions A B Weight Size Threaded Grooved Threaded Grooved C D E F G C.V.t Threaded Grooved Box Master In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Value Lbs. Kg. Lbs. Kg.Qty. Ctn.Qty. 1 25 3.33 85 - - 1.66 42 - - 2.11 54 3.81 97 2.31 59 6.14 156 1.75 44 57 6.1 2.77 - - 1 10 11/4 32 4.18 106 - - 2.09 53 - - 2.46 62 4.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 - - 1 8 11/2 40 4.70 119 - - 2.35 60 - - 2.95 74 4.46 113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 - - 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 161 3.50 89 245 10.7 4.86 9.7 4.40 1 4 21/2 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 t Note:C.V.is defined as the flow in GPM that a valve will carry with a pressure drop of 1.0 psi when the media is water at 60°F. 4/;► UL APPROVED © NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.800.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3221 •FAX:+1.574.295.3455 www.nibco.com 40 0 Ilre' I i::AZ 11. WC . 1197 IS Ir 4,0W4,4, Series 4000B A _ Vatlikft$ .R�4stzef§ervices Reduced Pressure Zone Assemblies 10/17/16 Sizes: 1/2" -2" (15-50mm) r fi,_ :11 77..E s r. .,_ :---;:,- :71 , _„. 2"(50mm)4000B-HC - 1/2"(15mm)4000B Features Series 4000B Reduced Pressure Zone Assemblies are designed to protect • Single access cover and potable water supplies in accordance with national plumbing codes and wa- modular check construction ter authority requirements. This series can be used in a variety of installa- for ease of maintenance tions, including the prevention of health hazard cross connections in piping • Top entry - all internals systems or for containment at the service line entrance. immediately accessible This series features two in-line, independent check valves, captured springs • Captured springs for safe and replaceable check seats with an intermediate relief valve. Its compact maintenance modular design facilitates easy maintenance and assembly access. Sizes 1/"- 1" (15-25mm) shutoffs have tee handles. • Internal relief valve for reduced installation clearances • Replaceable seats for Specifications economical repair P A Reduced Pressure Zone Assembly shall be installed at each potential • Bronze body construction for health hazard location to prevent backflow due to backsiphonage and/or durability - 1/2" to 2" (15-50mm) backpressure. The assembly shall consist of an internal pressure differential • Ball valve test cocks - relief valve located in a zone between two positive seating check modules screwdriver slotted -1/2" to 2" with captured springs and silicone seat discs. Seats and seat discs shall be (15-50mm) replaceable in both check modules and the relief valve. There shall be no • Large body passages provides threads or screws in the waterway exposed to line fluids. Service of all inter- low pressure drop nal components shall be through a single access cover secured with stain- • Compact, space saving design less steel bolts. The assembly shall also include two resilient seated isolation • No special tools required for valves, four resilient seated test cocks and an air gap drain fitting. The as- servicing sembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. The assembly shall be an Ames Com- pany Series 4000B. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.am esf i rewater.c o m „,, it Materials Pressure — Temperatures Bronze body construction, silicone rubber disc material in the Suitable for supply pressures up to 175psi (1. �r IS first and second check plus the relief valve. Replaceable poly- and water temperature to 180°F(75°C)contin �,, •f mer check seats for first and second checks. Removable stain- +01 b less steel relief valve seat. Stainless steel cover bolts. --N 1#- Standardly furnished with NPT body connections. For optional Available Models bronze union inlet and outlet connections,specify prefix U Suffix: Vail Fire&Emergency Services 10117116 (1/2” -2")(15-50mm). Series 4000B furnished with quarter turn, B -quarter-turn ball valves full port, resilient seated, bronze ball valve shutoffs. LBV - less ball valves Standards LH - locking handle ball valves(open position) AWWA C511-92, USC Manual 8th Edition, IAPMO File No. 1563 SH -stainless steel ball valve handles HC -21/2" inlet/outlet fire hydrant fitting (2" valve) Approvals S - bronze strainer ® G�pSS/FjFo Prefix: c Sus 4 OR c U� DS U - union connections 1013 B64.4 3/4"-2"(20-50mm) (LBV models only) Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, U. IMPORTANT Inquire with governing authorities for local installation requirements. Weights — Dimensions T A �" a L c '; B 1 IH . Z---,1i 11t •. LJ < L < M� < A Suffix HC - Fire Hydrant Fittings dimension "A" = 251/16 (637mm) MODEL SIZE(DN) DIMENSIONS STRAINER DIMENSIONS WEIGHT A B C D L M N in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. 40008"" 12 15 10 250 45/a 117 33/8 86 11/4 32 512 140 3 76 2 51 4.50 2.0 40008 M3"" 3/4 20 103/4 273 5 127 312 89 _ 11/2 38 63/4 171 _ 35/6 84 25/6 59 5.75 2.6 40008 M2*" 1 25 163/4 425 512 140 3 76 212 64 91/2 241 412 114 25/6 59 12.25 5.6 40006"" 11/4 32 173/8 44 116 150 312 89 212 64 113/8 289 518 130 31/8 79 14.62 6.6 4000B** 11/2 40 171/2 454 6 150 312 89 212 64 111e 283 51/2 149 33/4 95 16.32 7.4 40006"" 2 50 213/8 543 73/4 197 412 114 314 83 1312 343 63/6 157 41/2 124 30.00 13.6 Strainer sold separately **Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. 2 Capacity Performance as established by an independent testing laboratory. S+ Ir *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) ' ' Vail Fire&Emergency Services kPa psi 1/4" (8mm) kPa psi 1" (25mm) 10/17/16 COco 138 20 CO 207 30 J 117 17 J 172 25 0 N 96 14 3 138 20 76 11 CO W CO 103 15 - - - - N m 55 8 a 69 10 a 35 5 OP 0 .25 .50 .75 1 1.17 gpm 34 5 0 .95 1.9 2.9 3.8 4.5 Ipm 0 0 0 5 10 20 30 40 50 60 70 80 gpm Flow Rate oP 0 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi %" (10mm) kPa psi 11/4" (32mm) * 0 138 20 y 172 25 0 117 17 J 138 20 i 96 14 i 103 15 y 76 11 �� F.,y 55 8 1_ 69 10 a 35 5 a 34 5 AP 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm 0 0 0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 Ipm 0 10 20 30 40 50 60 70 80 gpm Flow Rate AP 0 38 76 114 152 190 228 266 304 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 1/2" (15mm) 11/2" (40mm) kPa psi * 172 25 kPa psi CA y 207 30 oCA 138 20 o 172 25 2 103 15 i 138 20 - y 69 10 y 103 15 o ai 69 10 a 35 5 a 34 5 Op 0 1 2.5 5 7.5 10 12.5 15 gpm 0 0 0 3.8 9.5 19 28.5 38 47.5 57 Ipm AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.52.3 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate 3/4" (20mm) 2" (50mm) kPa psi * kPa psi * 207 30 207 30 o165 24 y 172 25 -1124 124 18 J 138 20 3 83 12 / _ L 103 15 CO y 41 6 CO 69 10 a ` 2 34 5 0 0 - - - a 0 0 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm OP0 20 40 60 80 100 120 140 160 180 200 gpm OP 0 7.6 23 38 53 68 84 99 114 129 144 160175 Ipm 0 76 152 228 304 380 456 532 608 684 760 Ipm 7.5 15 fps 5 7.5 10 15 fps 2.3 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate 3 Wei OF gr, For additional information, visit our web site at: www.amesfirew. 4 Vail Fire&Emergency Services 10/17/16 A A M E S ISO 9001 FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-4000B 0625 ©Ames Fire&Waterworks, 2007 14,lt:i OF iv 4"51144. 44'1*(0 a. M. m.i Ir tqco I Fire & Building # Products rapid response..en.yServices HOME FIRE SPRINKLER 5YSTEN1 Technical Services: Tel: (800)381-9312/Fax: (800)791-5500 Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds 1, 1-1/2, and 2 Inch (DN25, DN40, and DN50) For NFPA 13D/13R Residential Sprinkler Systems General Technical Description Data .-`A "kR .111 The Riser Manifolds described in this Approvals # technical data sheet provide the nec- The Figure 513D (13D) and 513D/R essary waterflow alarm, pressure (13D/R) Riser Manifolds with a cover gauge,and drain equipment in a single tamper switch for the waterflow alarm assembly for use in NFPA 13D or 13R switch are UL Listed, ULC Listed, and residential sprinkler systems as fol- FM Approved. lows: The Figure 513D (13D) and 513D/R NFPA 13D (13D/R) Riser Manifolds without a 513D (13D) cover tamper switch for the waterflow • Figure 1 Inch 513D(DN2alarm switch are UL Listed and FM 1<11 Female Thread x Female Thread Approved. NFPA 13D/13R Maximum Working Pressure 175 psi (12,1 bar) line prior to performing the alarm test. • Figure 513D/R (13D/R) Assembly The second option is to install an In- 1-1/2 Inch (DN40) The manifold body of the Figure 513 is spector's Test Connection down- Male Thread x Female Threadductile iron, whereas the manifold stream of the Waterflow Alarm Switch. Male Thread x Male Thread body of the Figure 13 is cast iron. The (3) Never remove any piping compo- • Figure 513D/R (13D/R) two assemblies are completely inter- nent nor correct or modify any piping 2 Inch (DN50) changeable in function, application, deficiencies without first depressuriz- Groove x Groove and end-to-end laying length. ing and draining the system. Male Thread x Groove Finish Step 1. Install the manifold body with The variety of sizes and end connec- Red painted. the flow arrow pointing in the down- tions allow cost effective and easy stream position using threaded con- transition to check valves, control Installation nections and/or listed mechanical valves, and system piping. The Riser grooved connections, as applicable. Manifolds may be installed in either the The Riser Manifolds may be installed Step 2. Connect the drain line, and horizontal (flow switch on top)or verti- in either the horizontal (flow switch on then close the drain valve. cal (flow going up). top) or vertical (flow going up). The inlet of the Riser Manifold may be di- Step 3. Refer to Figure 4 for wiring WARNING rectly connected to a shut-off control guidance. All wiring must be per- The Riser Manifolds described herein valve. formed in accordance with the Author- must be installed and maintained in ity Having Jurisdiction and/or the Na- compliance with this document, as NOTES tional Electrical Code. well as with the applicable standards (1) Where applicable pipe thread Step4. Place the system in service by of the National Fire Protection Asso- sbe y ciation, in addition to the standards of sealant is to applied sparingly. Use filling the system with water.When fill any other authorities having d risdic- of a non-hardening pipe thread sealant ing the system, partially open the con- tion. Failure to do so may impair the is recommended. trol valve to slowly fill the system. Fill- performance of these devices. (2) Provisions for an alarm test flow ing the system slowly will help avoid must be made. The alarm test flow is damaging the waterflow alarm switch. The owner is responsible for maintain- to be through an orifice having a flow After the system is fully pressurized, ing their fire protection system and de- capacity equal to or smaller than the completely open the control valve. vices in proper operating condition. smallest orifice sprinkler in the system. The installing contractor or sprinkler One of two options can be considered. Step 5. Secure all supply valves manufacturer should be contacted The first option is to temporarily install open. with any questions. a test orifice in the outlet of the drain Page 1 of 6 APRIL, 2006 TFP960 oti OF go 4, 4r 4,4 140 lei Page 2 of 6 � NO. DESCRIPTION QTY. P/N n � �0J 1 1"Manifold Body, 3-1/2" I Female x Female NPT... 1 N/A (88,9 mm) Vail Fire&Emergen y Services 2 Waterflow Alarm Switch: 10/17/16 VSR-SF modified with �® Paddle,UL/FM 1 971-096-01 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-01 3 200 psi/1400 kPa A _____________________Water Pressure Gauge .. 1 2343 3 2 NOTES: / 1. Approximate weight,7.5 lbs.(3,4 kg). Waterflow 1.1 2. ULC Listed Manifolds are equipped with _ Cover Tamper Switches installed internal 9-3/4" to the Waterfow Alarm Switches. (247,7 mm) iq 3. CH:Common HardwareU3 2-7/8" -5/8" E mm) (92,11I mm) 1 (73,0 lii:iiiii. } 3/4"NPT Drain Valve 4-1/2" (Normally Closed) (114,3 mm) 10" (254,0 mm) FIGURE 1 1 INCH(DN25) RISER MANIFOLD ASSEMBLY AND DIMENSIONS NO. DESCRIPTION QTY. P/N } p ,_ 1 1-1/2"Manifold Body, 3-1/2" Male x Female NPT 1 N/A (88,9 mm) Male x Male NPT 1 N/A �_ 2 Waterflow Alarm Switch: 0\ VSR-SF modified with Paddle,UL/FM 1 971-096-00 VSR-SF modified with Paddle and Cover Tamper Switch,ULC/FM 1 976-519-02 3 300 psi/2000 kPa 3 / 2 Water Pressure Gauge .. 1 2341 NOTES: Waterfow 1.1 1 1. Approximate weight,8.7 lbs.(3,9 kg). . la M 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal 11-3/8" 1111I 1111 to the Waterflow Alarm Switches. (288,9 mm) i 3. CH:Common Hardware .911W 4-1/2" 5-3/8" (114,3 mm) (136,5 mm)1 ll ii, lido 1, NPT Drain Valve 2-1/8" (Normally Closed) (54,0 mm) 10"(254,0 mm) Male x Female NPT Manifold 11-1/8"(282,6 mm) Male x Male NPT - Manifold FIGURE 2 1-1/2 INCH(DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 1.4 OF iv )4 ! .10.0 TFP960 IS NO. DESCRIPTION QTY. P/N —7 f Oo•_ 0J 011 1 2"Manifold Body, 3-1/2" Groove x Groove 1 N/A (88,9 mm) Vail Fire&Emergency Services Male NPT x Groove 1 N/A 10/17/16 2 Waterflow Alarm Switch: i 0 -- VSC with Paddle, UL/FM 1 976-357-01 VSC with Paddle and Cover Tamper Switch, ULC/FM 1 976-520-01 ' 3 300 psi/2000 kPa 3 / 2 Water Pressure Gauge .. 1 2341 Optionally Grooved or NOTES: 1 Waterflow Male NPT 1. Approximate weight,11.0 lbs.(5,0 kg). II 401 Supply End NIP V II Connection 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal 12" to the Waterflow Alarm Switches. (304,8 mm) 3. CH:Common Hardware ES 4-1/2" 5-7/16" IIIb (114,3 mm) (138,1 mm) . 1111Lai' 1„ NPT FIGURE 3, Drain Valve _ 2-1/4" (Normally Closed) (57,2 mm) 2 INCH(DN50) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 13"(330,2 mm) Groove x Groove, Male NPT x Groove result in operation of the associated recorded for the system when it was Ca re a n d alarms. Consequently, notification first installed. must be given to the owner and the fire Maintenance department, central station, or other Alarm Test Procedure With A Test signal station to which the alarms are Orifice (See Installation Note 2) The following inspection procedure connected, and notification must be must be performed as indicated, in ad- given to the building occupants. Step 1. Temporarily install a test ori- dition to any specific requirements of Before closingfireprotection s stem fice in the drain line outlet. the NFPA, and any impairment must ay be immediately corrected. control valve for inspection or mainte- Step 2. Fully open the drain valve. nance work on the fire protection sys- Make certain that drainage water will The owner is responsible for the in- tem that it controls, permission to shut not cause any damage or injury. spection, testing, and maintenance of down the effected fire protection sys- Step 3.Verify operation of the associ- their fire protection system and de- tem must first be obtained from the vices in compliance with this docu- proper authorities and all personnel ated alarms. ment, as well as with the applicable who may be affected by this action Step 3. Close the drain valve. standards of the National Fire Protec- must be notified. tion Association (e.g., NFPA 25), in Step 4. Remove the test orifice from addition to the standards of any After placing a fire protection system the drain line outlet. authority having jurisdiction. The in- in service, notify the proper authorities stalling contractor or product manufac and advise those responsible for moni- Alarm Test Procedure With An turer should be contacted relative to toring proprietary and/or central sta- Inspector's Test Connection (See any questions. tion alarms. Installation Note 2) It is recommended that automatic Flow Test Procedure Step 1.Fully open the Inspector's Test sprinkler systems be inspected, Connection Valve. Make certain that tested, and maintained by a qualified Step 1. Fully open the drain valve. drainage water will not cause any dam- Inspection Service in accordance with Make certain that drainage water will age or injury. local requirements and/or national not cause any damage or injury. codes. Step 2.Verify operation of the associ Step 2. Verify that the residual (flow- ated alarms. NOTES ing) pressure indicated by the pres- Step 3. Close the Inspector's Test No attempt is to be made to repair any sure gauge is no less that originally Connection Valve. Riser Manifold component in the field. recorded for the system when it was Only the pressure gauge or waterflow first installed. alarm switch can be replaced. If any Step 3. Close the drain valve. other problems are encountered the entire riser manifold must be replaced. Step 4.Verify that the static(not flow ing) pressure indicated by the pres- The flow and alarm test procedure will sure gauge is no less that originally iitlei OF iv kir Page 4 of 6 � ec SI Ir SWITCH TERMINAL CONNECTIONS ur12(01 155 UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED Vail Fire&Emergency Services SINGLE An uninsulated section of a TERMINAL ENDS 10/17/16 tolivCONDUCTOR single conductor is not0.1) SEPARATE permitted to be looped around CONDUCTORS CLAMPING the terminal and serve as two %,... . PLATE separate connections.The TERMINALwire must be severed to serve INCOMING ON Ni...,••• as two separate connections, 4111h1115 4111.* . thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS SPDT(Form C) END OF LINE LOCAL RESISTOR CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE NC NO / NC IINIO NO• ti/iNC COM COM COM CONTROL POWER PANEL NO FLOW NON-SUPERVISED STYLE B/CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remove signaling unit,while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH(ULC ASSEMBLIES ONLY) CONTACTS SPDT(Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1 mA @ 5 VDC min. NO I\ • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 4 WIRING GUIDANCE )400 TFP960 � Limited Ordering 0 11, 412010 Warranty Inform a ti o n Vail Fire&Emergency Services 10/17/16 Products manufactured by Tyco Fire& Riser Manifold: Building Products (TFBP) are war- Specify; Size(specify), Figure(specify ranted solely to the original Buyer for 513D or 513D/R, (specify connection ten(10)years against defects in mate- type inlet x outlet) Riser Manifold rial and workmanship when paid for (specify-without or with)a cover tam- and properly installed and maintained per switch for the waterflow alarm under normal use and service. This switch, P/N (specify). warranty will expire ten (10) years from date of shipment by TFBP. No NOTES warranty is given for products or corn- Orders for Figure 513D or513D/R may ponents manufactured by companies be filled with a Figure 13D or 13D/R, not affiliated by ownership with TFBP respectively. The two assemblies are or for products and components which completely interchangeable in func- have been subject to misuse,improper tion, application, and end-to-end lay- installation, corrosion, or which have ing length. not been installed, maintained, modi- If a ULC Listing is required, the Riser fied or repaired in accordance with ap- Manifold must be ordered with a cover plicable Standards of the National Fire tamper switch for the waterflow alarm Protection Association, and/or the switch. standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either UL/ULC/FM Assemblies repaired or replaced, at TFBP's sole With Cover Tamper Switch option. TFBP neither assumes, nor 1 Inch(DN25) authorizes any person to assume for it, FT x FT P/N 4085 any other obligation in connection with 1-1/2 Inch(DN40) MT x FT P/N 4088 the sale of products or parts of prod- 1-1/2 Inch(DN40) ucts.TFBP shall not be responsible for MT x MT P/N 4089 sprinkler system design errors or inac- 2 Inch(DN50) curate or incomplete information sup- G x G P/N 4093 plied byBuyer or Buyers re re- 2 Inch(DN5o) y y p MT x G P/N 4094 sentatives. In no event shall TFBP be liable, in UL/FM Assemblies contract, tort, strict liability or under Without Cover Tamper Switch any other legal theory, for incidental, 1 Inch(DN25) indirect,special or consequential dam- FT x FT P/N 4047 p q 1-1/2 Inch(DN40) ages, including but not limited to labor MT x FT P/N 4057 charges, regardless of whether TFBP 1-1/2 Inch(DN40) was informed about the possibility of such damages, and in no event shall 2 Inch MT(DN5x MTo) P/N 4058 g G x G P/N 4059 TFBP's liability exceed an amount 2 Inch(DN50) equal to the sales price. MT x G P/N 4064 The foregoing warranty is made in lieu of any and all other warranties. ex- Replacement Parts: press or implied, including warranties Specify: (description)for use with Fig- of merchantability and fitness fora Dar- ure 513D, 513D/R, 13D, or 13D/R ticular purpose. Riser Manifold, P/N (Ref. Figure 1, 2 This limited warranty sets forth the ex or 2, as applicable). clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Wei OF gr- Page 6 of 6 . Vail Fire&Emergency Services 10/17/16 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 14,lt:i OF gr .4"5114.. a. 44.1 0 M. tLI CO Fire Suppression Istic.ib & BuildingProducts J r�#'' rapid respese y Services Technical Services 800-381-9312 I +1-401-781-8220 HOME FIRE SPRINKLER SYSTEM www.tyco-fire.com Series LFII Residential Sprinklers 4.9 K-Factor Pendent and Recessed Pendent Wet Pipe and Dry Pipe Systems General The Listing for the Series LFII Residential Pendent and Recessed Description Pendent Sprinklers now offers -- the laboratory approved option of The TYCO RAPID RESPONSE Series designing dry pipe residential sprinkler LFII Residential Pendent and Recessed systems. der • -- --. Pendent Sprinklers(TY2234)are deco- Through extensive testing, it has been1 rative, fast response, frangible bulb determined that the number of design sprinklers designed for use in residen- sprinklers (hydraulic design area) for r T tial occupancies such as homes,apart- the Series LFII Residential Pendent and _ ments, dormitories, and hotels. When Recessed Pendent Sprinklers(TY2234) aesthetics and optimized flow charac- need not be increased over the number teristics are the major consideration, of design sprinklers(hydraulic design the Series LFII Residential Sprinklers area)as specified for wet pipe sprinkler should be the first choice. systems,as is accustomed for density/ The Series LFII Residential Sprinklers area sprinkler systems designed per are intended for use in the following NFPA 13. NOTICE scenarios: Consequently, the Series LFII The Series LFII Residential Pendent • wet and dry pipe residential sprinkler Residential Sprinklers offer the features and Recessed Pendent Sprinklers of non-water filled pipe in addition to (TY2234) described herein must be systems for one- and two-family not having to increase the number of dwellinNFPA 13D and mobile homes per ds led and maintained in compli- esign sprinklers (hydraulic design anceinstalwith this document and the appli area) for systems designed to NFPA cable standards of the National Fire • wet and dry pipe residential sprinkler 13, 13D, or 13R. Non-water filled pipe Protection Association, in addition to systems for residential occupancies will permit options for areas sensitive the standards of any authorities having up to and including four stories in to freezing. jurisdiction. Failure to do so may impair height per NFPA 13R These Sprinklers have a 4.9 (70,6) the performance of these devices. • wet and dry pipe sprinkler systems K-Factor that provides the required for the residential portions of any residential flow rates at reduced Owners are responsible for main occupancy per NFPA 13 pressures, enabling smaller pipe sizes taining their fire protection system and and water supply requirements. devices in proper operating condition. Historically residential sprinklers, The installing contractor or sprinkler based on their Listing, have been The recessed version of the Series manufacturer should be contacted with limited to wet pipe sprinkler systems LFII Residential Sprinklers is intended any questions. to assure speed of water delivery for a for use in areas with finished ceilings. given prescribed design area(number It employs a two-piece Style 20 of design sprinklers). Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of IMPORTANT total adjustment from the flush ceiling IM to Technical Data position.The adjustment provided by Alwaysrefer for the "INSTALLER the Recessed Escutcheon reduces the Sheet TFP700 accuracy to which the pipe nipples to WARNING" that provides cautions the sprinklers must be cut. with respect to handling and instal- lation of sprinkler systems and The Series LFII Residential Pendent components. Improper handling and and Recessed Pendent Sprinklers have installation can permanently damage been designed with heat sensitivity a sprinkler system or its components and water distribution characteristics and cause the sprinkler to fail to proven to help in the control of residen- operate in a fire situation or cause it tial fires and to improve the chance for to operate prematurely. occupants to escape or be evacuated. Page 1 of 8 AUGUST 2011 TFP400 1,4 OF ir TFP4OO i� Page2of8 �IS r oj WET PIPE SYSTEM Minimum Flow and Residual Pressure(b) Vail Fire&Emerge icy Services 10117116 Maximum Maximum For Horizontal Coverage Spacing de) For Sloped Ceiling(c,d,e) For Sloped Ceiling(c,d,e) Area(a) (c, ,Ft. Ceiling (Greater than 2-Inch Rise up to (Greater than 4-Inch Rise up to (Maximum 2-Inch Rise Ft.x Ft. (m) for 12-Inch Run) Maximum 4-Inch Rise for 12-Inch Run) Maximum 8-Inch Rise for 12-Inch Run) (m x m) 155°F(68°C)or 155°F(68°C) 175°F(79°C) 155°F(68°C) 175°F(79°C) 175°F(79°C) 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (3,7 x 3,7) (3,7) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 14 x 14 14 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,3 x 4,3) (4,3) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 16 x 16 16 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,9 x 4,9) (4,9) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 18 x 18 18 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 20 x 20 20 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 21 GPM(79,5 LPM) 22 GPM(83,3 LPM) (6,1 x 6,1) (6,1) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 18.4 psi(1,27 bar) 20.2 psi(1,39 bar) (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13D 2010 applications,Horizontal Ceiling criteria shall be used for certain sloped ceiling configurations up to 8:12 pitch. Refer to TIA 1028R for allowed sloped ceiling limitations when using horizontal ceiling criteria. (d) For NFPA 13R applications,Horizontal Ceiling criteria may be used for sloped ceiling configurations up to 8:12 pitch when acceptable to the Local Authority Having Jurisdiction. (e) For NFPA 13 residential applications,the greater of 0.1 GPM/Ft.2 over the design area or the flow in accordance with the criteria in Table A must be used. TABLE A SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13, 13D AND 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b) Maximum Maximum Coverage Area(a) Spacing For Horizontal Ceiling(c) Ft.x Ft.(m x m) Ft.(m) (Maximum 2-Inch Rise for 12-Inch Run) 155°F(68°C) 175°F(79°C) 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) (3,7 x 3,7) (3,7) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 14 x 14 14 14 GPM(53,0 LPM) 14 GPM(53,0 LPM) (4,3 x 4,3) (4,3) 8.2 psi(0,57 bar) 8.2 psi(0,57 bar) 16 x 16 16 15 GPM(56,8 LPM) 15 GPM(56,8 LPM) (4,9 x 4,9) (4,9) 9.4 psi(0,65 bar) 9.4 psi(0,65 bar) 18 x 18 18 18 GPM(68,1 LPM) 18 GPM(68,1 LPM) (5,5 x 5,5) (5,5) 13.5 psi(0,93 bar) 13.5 psi(0,93 bar) 20 x 20 20 21 GPM(79,5 LPM) 21 GPM(79,5 LPM) (6,1 x 6,1) (6,1) 18.4 psi(1,27 bar) 18.4 psi(1,27 bar) (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-Factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13D 2010 applications,Horizontal Ceiling criteria shall be used for certain sloped ceiling configurations up to 8:12 pitch. Refer to TIA 1028R for allowed sloped ceiling limitations when using horizontal ceiling criteria. TABLE B SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) NFPA 13D HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEMS 14,lt:i OF iv ....r."514. 4,4.4 0 Is ir 4 7/16" (11,1 mm) 1/2„ ESCUTCHEON '.-112I#�' Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA. MAKE-IN SURFACE (73,0 mm) Vail Fire&:mergency Services 1 - Frame 10/17/16 2 - Button 3 - Sealing Assembly 1 4 - Bulb i 5 Compression 2 _____ ���' Sefew , r 21m �'® 6 Deflector* 3 ` r ;int (57,2 mm) cI I / -I (41,3 mm) WRENCH STYLE 20 RECESSED *Temperature c . FLATS ESCUTCHEON rating is --MC-- indicated Cindicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS(TY2234) 2-7/8" DIA. (73,0 mm) " 12,7 mm ' 1/2 7/16±1/8" ( ) \ (11,1±3,2 mm) .1/ 1/4" (6,4 mm) 2-1/4" / (57,2DIA. WRENCH RECESS FACE OF (END"A" USED SPRINKLER MOUNTING FOR TY2234) FITTING PLATE FIGURE 3 mom, W-TYPE 6 li i� SPRINKLER WRENCH Ag Mriil MOUNTING SURFACE 1i0 1/8" WRENCH . (3,2 mm) RECESS 1-3/8" (34,9 mm) CLOSURE TY2234 1-1/8" (28,6 mm) � FIGURE 2 1' 4 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE yi SERIES LFII RESIDENTIAL PENDENT SPRINKLERS(TY2234) :..ir PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH A . TFP400 � 15 Page4of8 Z. 141 - .4 4n ir Model/SprinklerNote: When conditions exist that are , , outside the scope of the provided A -1140 Identification criteria, refer to the Residential Sprinkler Design Guide TFP490 forit Fire&Emerges:y Services Number (SIN) the manufacturer's recommendations 17116 that may be acceptable to the localTY2234 authority having jurisdiction. Loco System TypesTechnical Per the UL Listing, wet pipe and drypipe systems may be utilized. Per the1 k Data C-UL Listing, only wet pipe systemsIi may be utilized. ��� Approvals • For dry systems corrosion-resistant 1 ■ • UL Listed for use with wet pipe and or internally galvanized pipe shall TY2234 dry pipe systems be utilized with the sprinklers de- • C-UL Listed for use only with wet scribed in this data sheet. B pipe systems • For dry systems not using CPVC, z • NYC Approved under MEA 44-03-E pendent sprinklers shall be installed 2 on return bends, where the sprin- f- For details on these approvals, refer klers, return bends, and branch E E to the Design Criteria section. line piping (that is, potential areas a Maximum Working Pressure for trapped water) are in areas at or a co 175 psi (12,1 bar) above 40°F(4°C). v Discharge Coefficient Refer to technical data sheet TFP485 M -. IN K=4.9 GPMCoef2(70,6 LPM/barli2) about the use of Residential Sprinklers in residential dry pipe systems. �r� Temperature Rating 155°F(68°C) or 175°F(79°C) NOTICE MAXIMUM TY2234 Finishes When corrosion-resistant or inter- ONE-HALF BEAM • White Polyester nally galvanized pipe and fittings with WIDTH PLUS a potable water supply is utilized, 2"(50,8 mm) • Chrome Plated return bends need not be installed. • Natural Brass However, any portion of the piping that FIGURE 5 has the potential to trap water must Physical Characteristics be maintained at or above 40°F(4°C) SPRINKLER POSITIONING Frame Brass unless provision to drain such areas is UNDER PRIMARY BEAMS Button Bronze provided and maintained dry. WET PIPE SYSTEMS ONLY SealingAssemblyBeryllium (Refer to the "Beam Ceiling yWater Delivery Design Criteria"section.) Nickel w/Teflon` When using the Series LFII Residential — Bulb(3 mm) Glass Pendent and Recessed Pendent Compression Screw Bronze Sprinklers (TY2234) in dry pipe NOTICE Deflector Bronze sprinkler systems, the requirements The number of "design sprinklers" Ejection Spring Stainless Steel for "Dry System Water 2D010 edition specified in NFPA 13D and 13R for wet Section 8.13D apply.theFepipe systems is to be applied when of NFPA For a residential designing dry pipe systems. There is Operation hazard, in no case shall the time of no need to increase the design area,as water delivery exceed 15 seconds for y it d for ens is the case /area systems, in The glass Bulb contains a fluid that the most remote operating sprinkler. y expands when exposed to heat.When accordance with U.S.Patent 7,712,543. the rated temperature is reached, the Hydraulic Design Refer to technical data sheet TFP485. fluid expands sufficiently to shatter the (NFPA 13D and 13R) glass Bulb, allowing the sprinkler to The minimum required sprinkler activate and flow water. flow rate for systems designed to NFPA 13D or NFPA 13R are given Design in Tables A and B as a function gof temperature rating and the Criteria maximum allowable coverage areas. The sprinkler flow rate is the minimum The RAPID RESPONSE Series LFII required discharge from each of the Residential Pendent and Recessed total number of"design sprinklers" as Pendent Sprinklers (TY2234) are UL specified in NFPA 13D or NFPA 13R. and C-UL Listed for installation in accordance with the following criteria. °Registered trademark of Dupont oiti OF 10 114. I 11 # pn IMP b A A A-H 14"(356 mm) Igo]Q f f f MAXIMUM Vail Fire&Emergen:y Services 10/17/16 11 11 �M AFOR=3'-PRI4"t0 6MARY BEA'-0"1 (1,MS0 to 1HAV ,8 m) 11 ING A 14"(356 mm)MAXIMUM DEPTH \si �� MAXIMUM COMPARTMENT WALLS FIGURE 6A oiti OF 10 o ."41,e ('lei Page 6 Pageof8 d51° b Oj 55 Vail Fire&Emergen:y Services 10/17/16 lrIi -1111T`_11Ik3IFk_. * *USE GDISTANCES6SHOWN ECIPTMES RE& N EXCEPT MEASUREMENTS lkii ARE TEFAC OF SOFFITSAKN INSTEADROMFOFES IV FROM COMPARTMENT WALL SURFACES OF alkAAA.SOFFIT NI .i COMPARTMENT V\ WALLS V 14,lt:i OF gr 4%."51144. a. kf la 15 ir Primary Beam Cross-Section Sprinkler Position Obtain a leak-tight 4O Maximum depth of 14 inches and the The deflector to bottom of primary sprinkler joint by applyin. '14201.1"J maximum width is unlimited.The cross- beams for the Series LFII Pendent and to-maximum torque of 7 to sectional shape of the primary beam Recessed Pendent Sprinklers(TY2234) (9,5 to 19,0 Nm). HigherViiivef&eflEtiiiVilacy services may be rectangular to circular. is to be 1-1/4 to 1-3/4 inches (Figure can distort the spriniffelllsnlet with 5A). The vertical center-line of the consequent leakage or impairment of Secondary Beam Cross-Section Series LFII Pendent Sprinklers is to be the sprinkler. Maximum depth to be no greater than no greater than half the primary beam the primary beam and the maximum cross-sectional width plus 2 inches Do not attempt to compensate width is unlimited.The cross-sectional from the centerline of the primary beam for insufficient adjustment in an shape of the secondary beam may be (Figure 5B). Escutcheon Plate by under- or over- rectangular to circular. tightening the Sprinkler. Re-adjust the Primary Beam Spacing NOTICE position of the sprinkler fitting to suit. The primary beams(Figure 6A)are to Core drilling of beams to allow the Series LFII Residential Pendent be 3 ft.-4 in.to 6 ft.from the compart- installation of sprinkler drops requires Sprinklers ment wall to center of the nearest beam consulting with a structural engineer. The Series LFII Residential Pendent and from center to center between Where core drilling is not permitted, Sprinklers must be installed in accor- beams. the previously stated sprinkler position dance with the following instructions. Secondary Beam Spacing criteria for the Series LFII Residential 1. Install pendent sprinklers in the Pendent and Recessed Pendent pendent position with the deflector The secondary beams principally run Sprinklers (TY2234)allows placement perpendicular to the primary beams. of the sprinkler drop adjacent to the parallel to the ceiling. Secondary beams of a depth equal to primary beam. 2. With pipe-thread sealant applied to the primary beam must be placed so the pipe threads, hand-tighten the that the beam pockets created by the Beam and Soffit Arrangements sprinkler into the sprinkler fitting. primary beams do not exceed 20 feet A soffit ispermitted to beplaced around in length(Figure 6B). 3. Tighten the sprinkler into the the perimeter of a compartment with sprinkler fitting using only the the beam arrangement within the W-Type 6 Sprinkler Wrench (Figure NOTICE soffited area(Figure 7). the beam pockets by 3).With reference to Figure 1,apply the Whent primary beams peockets created feet in The cross-section of the soffit may be the W-Type 6 Sprinkler Wrench to any size as long as it does not create the wrench flats. length, the installation will require the an obstruction to water distribution use of secondary beams as described per the obstruction rules of NFPA 13 for Series LFII Residential Recessed above. Otherwise, secondary beams residential sprinklers. Pendent Sprinklers need not be present. The Series LFII Residential Recessed Secondary beams of a cross-sectional When soffits are present, the previ Pendent Sprinklers must be installed depth greater than one-quarter the ously provided 3 ft. 4 inches to 6 ft. in accordance with the following depth of the primary beams are to be a "compartment wall to adjacent beam" instructions. minimum of 3 ft. - 4 inches from the distance for the primary and secondary compartment wall to center of the beams is to be measured from 1. Install recessed pendent sprinklers nearest beam and from center to center the face of the soffit as opposed to in the pendent position with the between beams(Figure 6C). the compartment wall. deflector parallel to the ceiling. Secondary beams of a cross-sectional Note: Although the distance to the 2. After installing the Style 20 Mounting depth no greater than one-quarter the beams is measured from the face of Plate over the sprinkler threads depth of the primary beams may be the soffit, the sprinkler coverage area and with pipe-thread sealant applied placed at any compartment wall to is to be measured from the compart- to the pipe threads, hand-tighten center of the nearest beam distance ment wall. the sprinkler into the sprinkler fitting. and from any center to center distance 3. Tighten the sprinkler into the sprin- between beams(Figure 6C). Installation kler fitting using only the W-Type 7 Lintels Recessed Sprinkler Wrench(Figure Lintels over doorways exiting The RAPID RESPONSE Series LFII 4). With reference to Figure 1, the compartment must be present. Residential Pendent and Recessed apply the W-Type 7 Recessed The minimum height for the lintels is Pendent Sprinklers (TY2234) must be Sprinkler Wrench to the sprinkler 8 inches or no less than the depth of the installed in accordance with the wrench flats. Primary Beams, whichever is greater. following instructions. 4. After the ceiling has been installed Sprinkler Types NOTICE or the finish coat has been applied, p yp slide on the Style 20 Closure over Series LFII Pendent and Recessed Do not install any bulb type sprinkler if the Series LFII Residential Sprinkler Pendent Residential Sprinklers the bulb is cracked or there is a loss of and push the Closure over the (TY2234), 155°F (68°C) and 175°F liquid from the bulb. With the sprinkler Mounting Plate until its flange (79°C). held horizontally, a small air bubble comes in contact with the ceiling. should be present. The diameter of the Sprinkler Coverage Area and Hy- air bubble is approximately 1/16 inch draulic Design (1,6 mm). The sprinkler coverage areas and hydraulic design criteria as presented in the Table A for "Horizontal Ceilings"are to be applied. 14,lt:i OF gr TFP400 0 0 Page 8 of 8 M - rrr 14.' Care and Responsibility lies with the owner for This limited warranty 0,IS ir 11 the inspection, testing, and mainte- exclusive remedy for 1201,10 Maintenance nance of their fire protection system on failure of or defect in and devices in compliance with this materials or componer.,m1F�.t &r.�.icy Services The RAPID RESPONSE Series LFII document, as well as with the appli- claim is made in contristirotort, strict Residential Pendent and Recessed cable standards of the National Fire liability or any other legal theory. Pendent Sprinklers (TY2234) must be Protection Association (that is, NFPA This warranty will apply to the full maintained and serviced in accordance 25), in addition to the standards of any extent permitted by law.The invalidity, with the following instructions. authorities having jurisdiction.Contact in whole or part, of any portion of this the installing contractor or sprinkler warranty will not affect the remainder. NOTICE manufacturer regarding any questions. Before closing a fire protection system Automatic sprinkler systems are Ordering main control valve for maintenance recommended to be inspected, work on the fire protection system tested, and maintained by a qualified Procedure that it controls, obtain permission to Inspection Service in accordance with shut down the affected fire protection local requirements and/or national Contact your local distributor for systems from the proper authorities codes. availability. When placing an order, and notify all personnel who may be indicate the full product name and Part affected by this action. Limited Number(P/N). Absence of the outer piece of an Sprinkler Assembly escutcheon, which is used to cover Warranty Specify Series LFII Residential Pendent a clearance hole, can delay sprinkler and Recessed Pendent Sprinkler operation in a fire situation. Products manufactured by Tyco Fire Suppression & Building Products (TY2234), K=4.9, with (temperature Owners must assure that the sprin- (TFSBP) are warranted solely to the rating), (finish), and P/N (below). klers are not used for hanging of any original Buyer for ten(10)years against 155°F(68°C)or objects and that the sprinklers are only defects in material and workmanship Chrome Plated P/N 51-201-9-155 cleaned by means of gently dusting when paid for and properly installed 155°F(68°C) with a feather duster;otherwise, non- and maintained under normal use White Polyester P/N 51-201-4-155 operation in the event of a fire or inad- and service. This warranty will expire 155°F(68°C) vertent operation may result. ten (10) years from date of shipment White by TFSBP. No warranty is given for (RAL9010)* P/N 51-201-3-155 Exercise care to avoid damage to products or components manufac- 155°F(68°c) sprinklers before, during, and after p Natural Brass P/N 51-201-1-155 installation. Never paint, plate, coat, tured by companies not affiliated by 175°F(79°C)or or otherwise alter automatic sprinklers ownership with TFSBP or for products Chrome Plated P/N 51-201-9-175 after they leave the factory. and components which have been 175°F(79°C) subject to misuse, improper instal- White Polyester P/N 51-201-4-175 Replace sprinklers that: lation, corrosion, or which have not 175°F(79°C) • were modified or over-heated. been installed, maintained, modified White • or repaired in accordance with appli- (RAL9010)* P/N 51-201-3-175 were damaged by dropping,striking, cable Standards of the National Fire 175°F(79°C) wrench twisting,wrench slippage, or Protection Association, and/or the Natural Brass P/N 51-201-1-175 the like. standards of any other Authorities *Eastern Hemisphere sales only. • are leaking or exhibiting visible signs Having Jurisdiction. Materials found by of corrosion. TFSBP to be defective shall be either Recessed Escutcheon • were exposed to corrosive repaired or replaced, at TFSBP's sole Specify Style 20 Recessed Escutcheon products of combustion but have option. TFSBP neither assumes, nor with finish and P/N. Refer to Technical not operated, if you cannot easily authorizes any person to assume for Data Sheet TFP770. remove combustion by-products it, any other obligation in connection with a cloth. with the sale of products or parts of Sprinkler Wrench • have a cracked bulb or have lost products.TFSBP shall not be respon- Specify W-Type 6 Sprinkler Wrench, liquid from the bulb. Refer to the sible for sprinkler system design errors P/N 56-000-6-387. Installation section in this data sheet. or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's Specify W-Type 7 Sprinkler Wrench, Initial and frequent visual inspections of representatives. P/N 56-850-4-001. random samples are recommended for In no event shall TFSBP be liable, in corrosion-resistant sprinklers to verify contract, tort, strict liability or under the integrity of the corrosion resistant any other legal theory, for incidental, material of construction. Thereafter, indirect, special or consequential annual inspections per NFPA 25 should damages, including but not limited to suffice. labor charges, regardless of whether Inspections of corrosion-resis- TFSBP was informed about the possi- tant sprinklers are recommended at bility of such damages, and in no close range, instead of from the floor event shall TFSBP's liability exceed an level per NEPA. Inspection at close amount equal to the sales price. range can better determine the exact The foregoing warranty is made in sprinkler condition and the long-term lieu of any and all other warranties, integrity of the corrosion-resistant express or implied, including warren- material, which can be affected by the ties of merchantability and fitness for a corrosive conditions present. particular purpose. Copyright©2006-2011 Tyco Fire Suppression &Building Products.All rights reserved. 40 OF IV 4"51144 )41 ig IITI ttiCO Worldwide www ty. # b�' Contacts O eb , IQQ ' Vail Fire&Emer.e y Services 1 RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General The Series LFII Residential Sprinklers has been designed with heat sensitivity Description and water distribution characteristics proven to help in the control of residen- The TYCO RAPID RESPONSE Series tial fires and to improve the chance for LFII Residential Horizontal Sidewall occupants to escape or be evacuated. ► e Sprinklers (TY2334) are decorative, fast response, frangible bulb sprin- NOTICE klers designed for use in residential The Series LFII Residential Horizontal occupancies such as homes, apart- Sidewall Sprinklers(TY2334)described ments, dormitories, and hotels. When herein must be installed and maintained aesthetics and optimized flow charac- in compliance with this document and teristics are the major consideration, with the applicable standards of the the Series LFII Residential Sprinklers National Fire Protection Association, in (TY2334)should be the first choice. addition to the standards of any author- The Series LFII Residential Sprinklers ities having jurisdiction. Failure to do so are intended for use in the following may impair the performance of these scenarios: devices. 0 • wet pipe residential sprinkler systems The owner is responsible for main- (" . 4 ' for one-and two-family dwellings and taining their fire protection system and , - •mobile homes per NFPA 13D devices in proper operating condition. #The installing contractor or sprinkler • wet pipe residential sprinkler systems manufacturer should be contacted with for residential occupancies up to and any questions. including four stories in height per NFPA 13R • wet pipe sprinkler systems for the Sprinkler Technical residential portions of any occupancy Identification per NFPA 13 Data The recessed version of the Series Number (SIN) Approvals LFII Residential Sprinklers is intended UL and C-UL Listed for use in areas with finished walls. TY2334 NSF Certified to NSF/ANSI 61 It employs a two-piece Style 20 For details on approvals, refer to the Recessed Escutcheon.The Recessed Design Criteria section. Escutcheon provides 1/4 inch(6,4 mm) of recessed adjustment or up to 1/2 inch Maximum Working Pressure (12,7 mm)of total adjustment from the Maximum 175 psi(12,1 bar) flush mounting surface position. The adjustment provided by the Recessed Discharge Coefficient Escutcheon reduces the accuracy to K=4.4 GPM/psi112(63,4 LPM/bar1I2) which the pipe nipples to the sprinklers must be cut. Temperature Rating 155°F(68°C)or 175°F(79°C) IMPORTANT FAlways refer to Technical Data Naturalinishes Sheet TFP700 for the "INSTALLER SignalBrass te WARNING" that provides cautions Chromeignal Plat with respect to handling and Plated installation of sprinkler systems and Physical Characteristics components. Improper handling and Frame Brass installation can permanently damage Button Bronze a sprinkler system or its components Sealing Assembly Beryllium and cause the sprinkler to fail to Nickel w/TEFLON operate in a fire situation or cause it Bulb 3 mm Glass to operate prematurely. Compression Screw Bronze Deflector Copper Page 1 of 6 APRIL 2013 TFP412 tellA OF go. TFP412 z � Page 2 of 6 _ *n SI ir Components: �� FLATS O'3 II, �� # 1 Frame �_�111��UOuim111� WRENCH 2 - Button I FLATS 3 - Sealing _ -CT?, /�I IIIIlII _ <il Fire&Emergency Services Assembly DEFLECTOROOF J Illlllll�i 1/2" NPT Ihh17h16 4 - Bulb `_,__ 5 - Compression 7/16"(11,1 mm) lllllllllll 2-7/8" DIA. Screw NOMINAL 1.�,' 6 - Deflector* 6* 5 4 2 MAKE-IN I� (73,0 mm) a_� _ CENTERLINE *Temperature rating -°®N\�o OF WATERWAY is indicated on top of Deflector. 7/16" 1 1 STYLE 20 (11,1 mm) 3 RECESSED 1-1/2" ESCUTCHEON END-OF- x(38,1 mm) ESCUTCHEON DEFLECTOR 2-1/8" PLATE SEATING BOSS (54,0 mm) - SURFACE RECESSED FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS(TY2334) 7/16±1/8" — —(11,1±3,2 mm) MOUNTING FACE OF WRENCH RECESS SURFACE SPRINKLER (END"A" USED FITTING FOR TY2334) TOP-OF- CLOSURE DEFLECTOR , FIGURE 3 TY2334\ . t W-TYPE 6 2-7/8" DIA. SPRINKLER WRENCH (73,0 mm) C 2-1/4" DIA. WRENCH (57,2 mm) RECESS 7/16" (11,1 mm) -, iv MOUNTING i 1, tEll PLATE END-OF- ______- DEFLECTOR DEFLECTOR 1/8" BOSS y (3,2 mm) PUSH WRENCH 1-1/4"(31,8 mm) _ 1/2"(12,7 mm) IN TO ENSURE 1" (25,4 mm) 1/4"(6,4 mm) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FIGURE 4 FOR USE WITH THE RAPID RESPONSE SERIES LFII W-TYPE 7 RECESSED RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER(TY2334) SPRINKLER WRENCH A OF iv 4 , z IITI Operation Obstruction to Water Distribution Step 2. With pipe "X <1 /" Sprinklers are to be located in accor- applied to the pipe t .,3 01..0 The glass bulb contains a fluid that dance with the obstruction rules of tighten the sprinkler into t' expands when exposed to heat.When NFPA 13D, 13R, and 13 as applicable fitting. Vail Fire 8 Emergency services the rated temperature is reached, the for residential sprinklers as well as with Step 3. Tighten the '''Rifkler into fluid expands sufficiently to shatter the obstruction criteria described within the sprinkler fitting using only the the glass bulb allowing the sprinkler to the Technical Data Sheet TFP490. W-Type 6 Sprinkler Wrench (Ref. activate and flow water. Operational Sensitivity Figure 3). With reference to Figure 1, The sprinklers are to be installed the W-Type 6 Sprinkler Wrench is to be Design with an end of defector-boss to wall applied to the wrench flats. distance of 1-1/8 to 6 inches. Series LFII Residential Recessed Criteria In addition the top-of-deflector-to- Horizontal Sidewall Sprinklers The TYCO RAPID RESPONSE Series ceiling distance is to be within the The Series LFII Recessed Horizontal range(Ref.Table A) being hydraulically Sidewall Sprinklers must be installed LFII (TY2334) Residential Horizontal calculated. in accordance with the following Sidewall Sprinklers are UL and C-UL instructions. Listed for installation in accordance Sprinkler Spacing with this section. The minimum spacing between sprin- Step A. Recessed horizontal side- klers is 8 feet (2,4 m). The maximum wall sprinklers are to be installed in the Residential Sprinkler Design Guide horizontal position with their center- When conditions exist that are outside spacing between sprinklers cannot line of waterway perpendicular to the the scope of the provided criteria, refer exceed the width of the coverage area back wall and parallel to the ceiling.The to the Residential Sprinkler Design (Ref.Table A)being hydraulically calcu word "TOP" on the Deflector is to face Guide TFP490 for the manufacturer's lated(e.g., maximum 12 feet for a 12 ft. towards the ceiling. that may be accept- x 12 ft. coverage area, or 16 feet for a recommendations to local authority havin 16 ft.x 20 ft.coverage area). Step B. After installing the Style 20 ableldito t Mounting Plate over the sprinkler jurInstallation threads and with pipe thread sealant System Type applied to the pipe threads, hand Only wet pipe systems may be utilized. The TYCO RAPID RESPONSE Series tighten the sprinkler into the sprinkler LFII (TY2334) Residential Horizontal fitting. Ceiling Type Sidewall Sprinklers must be installed in Step C. Tighten the sprinkler into the Smooth flat horizontal, or beamed, or accordance with this section. sprinkler fitting using only the W-Type sloped, in accordance with the 2013 7 Recessed Sprinkler Wrench (Ref. Edition of NFPA 13D, 13R, or 13 as General Instructions applicable. Do not install any bulb-type sprinkler if Figure 4).With reference to Figure 1,the the bulb is cracked or there is a loss of W-Type 7 Recessed Sprinkler Wrench Hydraulic Design liquid from the bulb. With the sprinkler is to be applied to the sprinkler wrench (NFPA 13D and 13R) held horizontally, a small air bubble flats. For systems designed to NFPA 13D should be present.The diameter of the Step D. After the wall has been or NFPA 13R, the minimum required air bubble is approximately 1/16 inch installed or the finish coat has been sprinkler flow rate are given in Table (1,6 mm). applied, slide on the Style 20 Closure A as a function of temperature rating A leak-tight 1/2 inch NPT sprinkler over the Series LFII Sprinkler and push and the maximum allowable coverage joint should be obtained by applying a the Closure over the Mounting Plate areas. The sprinkler flow rate is the minimum to maximum torque of 7 to 14 until its flange comes in contact with minimum required discharge from ft.-lbs. (9,5 to 19,0 Nm). Higher levels the wall. each of the total number of "design of torque can distort the sprinkler Inlet sprinklers"as specified in NFPA 13D or with consequent leakage or impairment NFPA 13R. of the sprinkler. Hydraulic Design Do not attempt to compensate for (NFPA 13) insufficient adjustment in the sprinkler For systems designed to NFPA 13, by under- or over-tightening the the number of design sprinklers is sprinkler. Re-adjust the position of the to be the four most hydraulically sprinkler fitting to suit. demanding sprinklers. The minimum Series LFII Residential Horizontal required discharge from each of the Sidewall Sprinklers four sprinklers is to be the greater of The Series LFII Horizontal Sidewall the following: Sprinklers must be installed in accor- • The flow rates given in Table A as a dance with the following instructions. function of temperature rating and the Step 1. Horizontal Sidewall sprin- maximum allowable coverage area. klers are to be installed in the hori- • A minimum discharge of 0.1 zontal position with their centerline of gpm/ft2 over the "design area" waterway perpendicular to the back comprised of the four most hydrau- wall and parallel to the ceiling. The lically demanding sprinklers for word "TOP" on the Deflector is to face the actual coverage areas being towards the ceiling with the front edge protected by the four sprinklers. of the Deflector parallel to the ceiling. TFP412 z � Page 4 of 6 _ *n IS Ir +Dnp WET PIPE SYSTEM ' i� "�Ib# Max.Coverage Max. Minimum Flow and Residual Pressure(b,c) Area(a) Spacing Ordinary Temp.Rating Intermediate Temp.Rating van i-ire a.emergency Services 10/17/ Width x Length(d) Ft. 155°F(68°C) 175°F(79°C) 1(07/Minimum Ft.x Ft. (m) Flow Pressure Flow Pressure Deflector to Installation Spacing Ceiling Type Ft. (m x m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 12 13 8.7 13 8.7 (3,7 x 3,7) (3,7) (49,2) (0,60) (49,2) (0,60) 14 x 14 14 14 10.1 14 10.1 (4,3 x 4,3) (4,3) (53,0) (0,70) (53,0) (0,70) 16 x 16 16 16 13.2 16 13.2 (4,9 x 4,9) (4,9) (60,6) (0,91) (60,6) (0,91) 16 x 18 16 19 18.6 19 18.6 4 to (4,9 x 5,5) (4,9) (71,9) (1,28) (71,9) (1,28) 6 inches 16 x 20 16 23 27.3 23 27.3 (4,9 x 6,1) (4,9) (87,1) (1,88) (87,1) (1,88) 18 x 18 18 23 27.3 23 27.3 (5,5 x 5,5) (5,5) (87,1) (1,88) (87,1) (1,88) 18 x 20 18 26 34.9 26 34.9 usingRecSssed le 20 (5,5 x 6,1) (5,5) (98,4) (2,41) (98,4) (2,41) Escutcheon or 8 12 x 12 12 13 8.7 13 8.7 non-recessed (2,4) (3,7 x 3,7) (3,7) (49,2) (0,60) (49,2) (0,60) per NFPA 13D, 13R,or 13 14 x 14 14 14 10.1 14 10.1 (4,3 x 4,3) (4,3) (53,0) (0,70) (53,0) (0,70) 16 x 16 16 17 14.9 17 14.9 (4,9 x 4,9) (4,9) (64,3) (1,03) (64,3) (1,03) 16 x 18 16 20 20.7 20 20.7 6 to (4,9 x 5,5) (4,9) (75,7) (1,43) (75,7) (1,43) 12 inches 16 x 20 16 23 27.3 23 27.3 (4,9 x 6,1) (4,9) (87,1) (1,88) (87,1) (1,88) 18 x 18 18 23 27.3 23 27.3 (5,5 x 5,5) (5,5) (87,1) (1,88) (87,1) (1,88) 18 x 20 18 26 34.9 26 34.9 (5,5 x 6,1) (5,5) (98,4) (2,41) (98,4) (2,41) (a) For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K- factor.Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications,the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width(backwall where the sprinkler is located)times the Length(horizontal throw of sprinkler). TABLE A WET PIPE SYSTEMS SERIES LFII(TY2334)RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA 14 OF get,. itv ! lo Care and Ordering of Maintenance Procedure Vail Fire&Emergency Services The TYCO RAPID RESPONSE Series Contact your local distributor for avail- 10/17/16 LFII (TY2334) Residential Horizontal ability. When placing an order, indicate Sidewall Sprinklers must be maintained the full product name and Part Number and serviced in accordance with this (P/N). section. Before closing a fire protection Sprinkler Assembly system main control valve for main- Specify: Series LFII (TY2334), K=4.4, tenance work on the fire protection Residential Horizontal Sidewall system which it controls, permission Sprinkler, (specify)temperature rating, to shut down the affected fire protec- (specify)finish, P/N(specify). tion system must be obtained from the 155°F(65°C) proper authorities and all personnel Natural Brass P/N 51-215-1-155 who may be affected by this action Signal White(RAL9003) P/N 51-215-4-155 must be notified. Chrome Plated P/N 51-215-9-155 Absence of an Escutcheon Plate may 175°F(79°C) delay the sprinkler operation in a fire Natural Brass P/N 51-215-1-175 situation. Signal White(RAL9003) P/N 51-215-4-175 Chrome Plated P/N 51-215-9-175 The owner must assure that the sprin- klers are not used for hanging any Recessed Escutcheon objects and that the sprinklers are only Specify:Style 20 Recessed Escutcheon cleaned by means of gently dusting with(specify")finish,P/N(specify*). with a feather duster; otherwise, non- ,Refer to Technical Data Sheet TFP770. operation in the event of a fire or inad- vertent operation may result. Sprinkler Wrench Sprinklers which are found to be Specify: W-Type 6 Sprinkler Wrench, leaking or exhibiting visible signs of P/N 56-000-6-387. corrosion must be replaced. Specify: W-Type 7 Sprinkler Wrench, Automatic sprinklers must never be P/N 56-850-4-001. painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during,and after installation.Sprinklers damaged by dropping,striking,wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction.The installing contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 14, OF iv TFP412 taM Page 6 of 6 _ 0 # ! Vail Fire&Emergency Services 10/17/16 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products,LP. All rights reserved. Vico is trademark of The DuPont Corporation. Wei OF iv 4"4144. 44'1*(0 tqco 'Fire & Building110 Products Vail Fire&Emergeru y Services 10/17/16 Technical Services: Tel: (800)381-9312/Fax: (800)791-5500 Style 10, 20, 30, 40, and 50 Recessed Escutcheons & Protective Paint Caps For Automatic Sprinkler Recessed Installation WARNING G e n e ra I The Recessed Escutcheons described herein must be installed and main- Description ain- Descri ption tained in compliance with this docu- ment, as well as with the applicable The Tyco®Style 10,20,30,40,and 50 standards of the National Fire Protec „ y � Recessed Escutcheons are designed tion Association, in addition to the for recessed installation with certain standards of any other authorities hav- pendent and horizontal sidewall sprin- ing jurisdiction. Failure to do so may klers. They are intended for use in impair the performance of these de- y • areas with finished ceilings or walls, vices. and the adjustment provided by these escutcheons reduces the accuracy to The owner is responsible for maintain- which fixed piping to the sprinklers ing their fire protection system and de- must be cut,while providing a decora- vices in proper operating condition. tive recessed sprinkler installation. The installing contractor or sprinkler manufacturer should be contacted The two-piece Style 10(1/2 inch NPT) with any questions. or Style 40 (3/4 inch NPT) Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or 3/4 inch (19,1 mm) of total adjustment Technical from the flush position. The two-piece Style 20(1/2 inch NPT)or Style 30(3/4 Data inch NPT) Recessed Escutcheon pro- vides 1/4 inch (6,4 mm) of recessed Approvals adjustment or 1/2 inch (12,7 mm) of Approval information, as applicable, total adjustment from the flush posi- for the Style 10, 20, 30, 40, and 50 tion. The two-piece Style 50 (1/2 inch Recessed Escutcheons is detailed in NPT) Recessed Escutcheon provides individual pendent and horizontal side- 1/4 inch (6,4 mm) of recessed adjust- wall sprinkler data sheets that include ment or 3/8 inch (9,5 mm) of total ad- details of recessed installation. justment from the flush position. The Style 10, 20, 30, 40, and 50 Re- Materials and Finishes Carbon steel chrome plated, white cessed Escutcheons are redesigna- coated, or brass plated. Series 300 tions for Central,Gem and Star brands stainless steel white coated or plain as follows: unpolished. (Other colors are avail- Style Central Gem Star able on special request.) 10 3211 F700(1/2") 2085 20 3221 F705(1/2") 2084 30 4221 F705(3/4") 2086 40 4211 F700(3/4") 2088 50 307X —As an option, Protective Paint Caps (Ref.Figures 6 and 7)may be obtained to help protect the sprinkler while ceil- ings or walls are being finished. The Model Z-392 is suitable for use with the Style 10, 20, 30, or 40 Recessed Es- cutcheons,whereas the Model Z-84 is suitable for use with the Style 50 Re- cessed Escutcheon. Page 1 of 4 DECEMBER, 2007 TFP770 14F iv4,! Page 2 of 4 � .15 IS ir 1/2"NPT 1-15/16"DIA. CLOSURE r1 c� / 0 II MOUNTING PLATE (49,2 mm) I n.7 !�a 11 a t • ,33(100 # Installation information, Ap for the Style 10, 20, 3017419 an. U Services ®r 1-1/8" _ Recessed Escutcheons is detailed in (28,6 mm) individual pendent and horizontal side- wall sprinkler data sheets that include ff details of recessed installation. FLUSH TO • 2-7/8"DIA. • 1/8" NOTE 3/4"(19,1 mm) (73,0 mm) (3,2 mm) The Style 10, 20, 30, 40, and 50 Re- FIGURE 1 cessed Escutcheons must only be STYLE 10 ESCUTCHEON, 1/2 INCH NPT—3/4 INCH ADJUSTMENT used with sprinklers for which they have been specifically laboratory ap- proved(i.e., UL, C-UL, ULC, or FM). 1/2"NPT 1-15/16"DIA. CLOSURE y As an option, Protective Paint Caps MOUNTING PLATE (49,2 mm) (Ref. Figures 6 and 7) may be utilized to help protect the sprinkler while the ceiling or wall, as applicable, is being — I®r ....--- 1 13/16" (painting or plastering for ex- 0,6 mm) ample). The Protective Paint Cap is _ (20,6 simply pushed over the Mounting Plate 1 } of the Recessed Escutcheon in lieu of the Closure. After the ceiling or wall FLUSH TO 2-7/8"DIA. 1/8" finish is completed, the Protective 1/2"(12,7 mm) (73,0 mm) (3,2 mm) Paint Cap is removed and the Closure is installed. FIGURE 2 The Protective Paint Cap may be dis- STYLE 20 ESCUTCHEON, 1/2 INCH NPT— 1/2 INCH ADJUSTMENT carded as a plastic commodity (Low Density Polyethylene Recycling Cate- 3/4"NPT - 1-15/16"DIA. CLOSURE gory 4)in conformance with local regu- MOUNTING PLATE (49,2 mm) lations, or the Protective Paint Cap may be be reused. NOTE 13/16" The sprinkler cannot operate properly (20,6 mm) with the Protective Paint Cap in place. 1 FLUSH TO 2-7/8"DIA. 1/8" 1/2"(12,7 mm) (73,0 mm) (3,2 mm) FIGURE 3 STYLE 30 ESCUTCHEON, 3/4 INCH NPT— 1/2 INCH ADJUSTMENT 3/4"NPT - 1-15/16"DIA. CLOSURE MOUNTING PLATE (49,2 mm) iir - _ 1-1/8" (28,6 mm) FLUSH TO 2-7/8"DIA. 1/8" 3/4"(19,1 mm) (73,0 mm) (3,2 mm) FIGURE 4 STYLE 40 ESCUTCHEON, 3/4 INCH NPT—3/4 INCH ADJUSTMENT iitlei OF gr TFP770iiif � IS ir 1/2"NPT y 1-13/16"DIA. CLOSURE 4 MOUNTING PLATE (46,0 mm) Care }aQn d /'�/ ) #�' ■�• a I n `e n a call Fife 7 mergency Services 10/17/16 ii i5. 13/16" Specific requirements of the NFPA (20,6 mm) must be performed, and any impair- ment must be immediately corrected. NOTE FLUSH TO 2-7/8"DIA. 3/32" Absence of an escutcheon, used to 3/8"(9,5 mm) (73,0 mm) (2,4 mm) cover a clearance hole, may delay the FIGURE 5 time to sprinkler operation in a fire STYLE 50 ESCUTCHEON, 1/2 INCH NPT—3/8 INCH ADJUSTMENT situation. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- 3-1/4" vices in compliance with this docu- ment,�(82 mm) as well as with the applicable f/C****k.,,,Pft. ---- standards of the National Fire Protec- tion Association (e.g., NFPA 25), in Kil -‘ ...-iip addition to the standards of any authority having jurisdiction. The in- 1-7/8"DIA. stalling contractor or product manufac- (48 mm) rek FRICTION FIT turer should be contacted relative to PAINT CAP OVER any questions. ESCUTCHEON IP MOUNTING PLATE Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accord- ance with local requirements and/or FIGURE 6 national codes. MODEL Z-392 PROTECTIVE PAINT CAP (For use with Style 10, 20, 30, or 40 Recessed Escutcheons) 2-1/2" (64 mm) r ab;- Jg-r 1 1-13/16"DIA. FRICTION FIT (46 mm) PAINT CAP OVER ESCUTCHEON MOUNTING PLATE FIGURE 7 MODEL Z-84 PROTECTIVE PAINT CAP (For use with Style 50 Recessed Escutcheons) Page 4 of 4 � IS ir Limited Ordering STAINLESS STEEL 01 #/1 Style 10, Warranty Information 1/2"NPT(15mm)White VonimKp iefgpf!Fy Services Products manufactured by Tyco Fire& When placing an order,indicate the full Plain Unpolished 6 701-1-010 Building Products (TFBP) are war- product name. Refer to Price List for style 20 ranted solely to the original Buyer for complete listing of Part Numbers. 1/2"NPT(15mm) ten(10)years against defects in mate- White P/N 56-705-S-OW rial and workmanship when paid for Contact your local distributor for avail- 30 and properlynstalled and maintained Style 3/4"N iability. /a"NPT(20mm) under normal use and service. This Recessed Escutcheon: White P/N 56-705-S-011 warranty will expire ten (10) years Specify: Style (specify) Recessed Es- style 40 from date of shipment by TFBP. No cutcheon with (specify material and 3/4"NPT(20mm)White P/N 56-700-S-010 warranty is given for products or com- finish), P/N (specify). Plain Unpolished P/N 56-700-1-010 ponents manufactured by companies not affiliated by ownership with TFBP Style 50 or for products and components which CARBON STEEL 1/2"NPT(15mm) have been subject to misuse,improper White P/N 56-711-S-010 installation, corrosion, or which have Style 10, not been installed, maintained, modi- 1/2"NPT(15mm) Protective Paint Cap: fled or repaired in accordance with a Chrome Plated P/N 56-701-9-010 Specify: Model (specify) Protective P p- White P/N 56-701-4-010 Paint Cap, P/N (specify). plicable Standards of the National Fire Brass Plated P/N 56-701-2-010 Protection Association, and/or the White(RAL9010)" P/N 56-701-3-010 Model Z-392 P/N 56-711-1-392 standards of any other Authorities Style 20 Model Z-84 P/N 56-711-1-084 Having Jurisdiction. Materials found 1/2"NPT(15mm) by TFBP to be defective shall be either Chrome Plated P/N 56-705-9-010 repaired or replaced, at TFBP's sole White P/N 56-705-4-010 option. TFBP neither assumes, nor Brass Plated P/N 56-705-2-010 authorizes any person to assume for it, White(RAL9010)" P/N 56-705-3-010 any other obligation in connection with Style 30 the sale of products or parts of prod- 3/4"NPT(20mm) ucts.TFBP shall not be responsible for Chrome Plated P/N 56-705-9-011 sprinkler system design errors or inac- White P/N 56-705-4-011 curate or incomplete information sup- Brass Plated P/N 56-705-2-011 plied by Buyer or Buyer's repre White(RAL9010)" P/N 56-705-3-011 sentatives. Style 40 3/4"NPT(20mm) In no event shall TFBP be liable, in Chrome Plated P/N 56-700-9-010 contract, tort, strict liability or under White P/N 56-700-4-010 any other legal theory, for incidental, Brass Plated P/N 56-700-2-010 indirect,special or consequential dam- White(RAL9010)" P/N 56-700-3-010 ages, including but not limited to labor Style 50 charges, regardless of whether TFBP 1/2"NPT(15mm) was informed about the possibility of Chrome Plated P/N 56-711-9-010 such damages, and in no event shall White P/N 56-711-4-010 exceed an amount Brass Plated P/N 56-711-2-010 TFBP's liability White(RAL9010)" P/N 56-711-3-010 equal to the sales price. The foregoing warranty is made in lieu Eastern Hemisphere sales only. of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. ©2007 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 4"51144. kir*15 RIX tqco/Fire & Building Products Vail Fire&Emerge y Services 10/17/16 Technical Services: Tel: (800) 381-9312 / Fax: (800)791-5500 Style 65 One-Piece Flush Escutcheon Style 401 Two-Piece Deep Escutcheon 1/2 Inch and 3/4 Inch NPT GeneralWARNINGS The Style 65 and 401 Escutcheons de- Description scribed herein must be installed and p maintained in compliance with this The Tyco°Style 65 and 401 Escutch- document, as well as with the applica- eon Plates illustrated in Figures 1 and 2 ble standards of the National Fire Pro- are designed for use with pendent and tection Association, in addition to the horizontal sidewall automatic sprin- standards of any other authorities hav- klers in fire protection systems where ing jurisdiction. Failure to do so may the piping is installed above a ceiling impair the performance of these or behind a wall. They are used to im- devices. STYLE 65 prove the overall appearance of the in- The owner is responsible for maintain- ONE-PIECE ESCUTCHEON stallation by concealing the clearance ing their fire protection system and de- holes required for the connecting pip- vices in proper operating condition. ing and fittings to the sprinkler. The installing contractor or sprinkler The Escutcheon Plates are available manufacturer should be contacted in two styles: Style 65 flush one-piece with any questions. iimar (non-adjustable),and Style 401 deep two-piece(adjustable). Technical 'w The flush one-piece (non-adjustable) I Style 65 Escutcheon Plates(Fig. 1)are Data / — used where the position of the sprin- kler "escutcheon plate seating sur- Approvals face"(relative to the ceiling line or wall) With reference to NFPA 13, listings/ap- can be fixed by adjusting the length of provals are not required for metallic the interconnecting piping. escutcheons used for non-recessed The two-piece Style 401 Escutcheon applications. Plates(Fig.2)are used where it is nec- Finishes STYLE 401 essary to position the sprinkler away Chrome, White, or Brass from the ceiling/wall surface so that Material TWO-PIECE ESCUTCHEON spray will not be adversely affected by Carbon Steel protruding obstructions such as light fixtures and HVAC diffusers. The adjustment provided by the Style 401 Escutcheon Plates reduces the ac- curacy to which the length of the fixed pipe drops or horizontal pipe runs to the sprinklers must be cut, and it pro- vides additional flexibility in the inter- connecting pipe. The separable, two-piece design of the Style 401 allows installation of the sprinklers and pressure testing of the fire protection system/evaluation of leak tightness prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit the removal of suspended ceiling panels, for access to building service equipment, without having to first shut down the fire protection sys- tem and remove sprinklers. Page 1 of 4 DECEMBER, 2007 TFP777 iitit% OF go. 4! Page 2 of 4 a. C 4 IS ir 2-13/16" DIA. 3-1/2"DIA. � # 13/1 DI (89,0 mm) (71,4m) 2-1/2"DIA. Vail Fire&Emergency Services 2" DIA. (63,5 mm) r 10/17/16 (50,8 mm) sti 2-1/4"DIA. y (57,2 mm) f CEILING CEILING I. ,.. SURFACE iiiim. SURFACE /ME Err El ) —v SKIRT * 2-7/8" MAX. wfo 1/2" (73,0 mm) FRICTION MIN.1-7/8"(47,6 mm) FIT '.1/2"OR �__ (12,7 mm) 3/4"NPT CUP* OPENING ESCUTCHEON `f PLATE SEATING 1/2"OR SHOWN WITH SURFACE 3/4" NPT -d _ SERIES TY-FRB OPENING ESCUTCHEON 5.6 K-FACTOR PLATE SEATING PENDENT SPRINKLER SHOWN WITH SURFACE FOR REFERENCE SERIES TY FRB 5.6 K-FACTOR PENDENT SPRINKLER *ORDERED FOR REFERENCE SEPARATELY FIGURE 1 FIGURE 2 STYLE 65 ONE-PIECE STYLE 401 TWO-PIECE DEEP FLUSH ESCUTCHEON ADJUSTABLE ESCUTCHEON 14, OF grA TFP777 � � C Installation Step 4. Usingthe a p ro riate s rin- O kler wrench, tighten the pp into # NOTES the fitting. A leak tight 1/2 inch NPT sprinkler joint Step 5. After a suspended ceiling has Vail Fire e&Emergency Services 10should be obtained with a torque of 7 been installed or the finish coat has to 14 ft.lbs. and 10 to 20 ft.lbs. should been applied to a wall or fixed ceil- be sufficient for a 3/4 inch NPT sprin- ing (as appropriate), align the detents kler.Higher levels of torque may distort in the skirt over those in the cup and the sprinkler orifice seat with conse then slide the cup over the skirt until quent leakage. it comes in contact with the mount- ing surface. Do not push the skirt such Do not attempt to make-up for insuf- that it will lift a ceiling tile out of its nor- ficient adjustment in an Escutcheon mal position. Plate by under- or over-tightening the Holding the skirt in contact with the sprinkler. Readjust the position of the mounting surface, rotate the skirt ap- sprinkler fitting to suit. proximately 1/8-turn in relation to the Style 65 cup creating a friction fit between the The pipe connected to the sprinkler skirt detents and the cup wall, to hold fitting must be cut so that the "es- the Escutcheon Plate firmly together. cutcheon plate seating surface" is at the proper nominal distance in front Care and of the wall or below the ceiling. Man- ufacturing variations in the take-out of Maintenance the fittings as well as the make-in of the sprinklers (as permitted by ANSI The following inspection procedure B1.20.1) may require that trial cuts of must be performed as indicated, in the connecting pipe be made. addition to any specific requirements Proceed with the assembly as follows: of the NFPA.Any impairments must be Step 1. Insert the threaded end of immediately corrected. the sprinkler through the Escutcheon The owner is responsible for the in- Plate. spection, testing, and maintenance of Step 2. Apply pipe thread seal- their fire protection system and devic- ant sparingly to the sprinkler threads es in compliance with this document, only. Use of a non-hardening type of as well as with the applicable stan- Teflon based pipe thread sealant is dards of the National Fire Protection recommended. Association(e.g., NFPA 25), in addition Step 3. Hand tighten the sprinkler with to the standards of any authority hav- the attached Escutcheon Plate into the ing jurisdiction. The installing contrac- sprinkler fitting. tor or product manufacturer should be Step 4. Using the appropriate sprin contacted relative to any questions. kler wrench, tighten the sprinkler into It is recommended that automatic sprin- the fitting. kler systems be inspected, tested, and maintained by a qualified Inspection Style 401 She pipe connected to the sprinkler fit Service in accordance with local re- ting must be cut so that the "escutch- eon plate seating surface" is at the After placing a fire protection system proper nominal distance in front of the in service, notify the proper authorities wall or below the ceiling. and advise those responsible for mon- Proceed with the assembly as follows: itoring proprietary and/or central sta- Step 1. Separate the two pieces of tion alarms. the Escutcheon Plate and screw the cup onto the sprinkler until the plate is engaged onto the last thread of the sprinkler. Step 2. Apply a brush-on pipe thread sealant sparingly to the sprinkler threads only. Use of a non-hardening type of Teflon based pipe thread seal- ant is recommended. Step 3. Hand tighten the sprinkler with the attached inner plate into the sprin- kler fitting. 40 OF ge Page 4 of 4 � 15 Limited Ordering ojinw Warranty Procedure Vail Fire&Emergency Services Products manufactured by Tyco Fire When placing an order, indicate the full 10/17/16 & Building Products (TFBP) are war- product name. Contact your local dis- ranted solely to the original Buyer for tributor for availability. ten (10)years against defects in mate- Style 65 rial and workmanship when paid for Specify: Style 65 Flush One-Piece Es- and properly installed and maintained cutcheon with (1/2 or 3/4) NPT Open- under normal use and service. This ing and (Chrome,White, or Brass) Fin- warranty will expire ten(10)years from ish, P/N (specify). date of shipment by TFBP. No warran- ty is given for products or components Style 65 One-Piece Escutcheon manufactured by companies not af- 1/2"Chrome P/N 1153 filiated by ownership with TFBP or for 3/4"Chrome P/N 1152 products and components which have White P/N 1174 been subject to misuse, improper in- stallation, 31//24,,"White P/N 1175 corrosion,or which have not 1/2"Brass P/N 1150 been installed, maintained,modified or 3/4"Brass P/N 1184 repaired in accordance with applicable Style 401 Cup* Standards of the National Fire Protec- Specify:Style 401 Cup with(1/2 or 3/4) tion Association, and/or the standards NPT Opening and (Chrome, White, or of any other Authorities Having Juris- Brass) Finish, P/N (specify). diction. Materials found by TFBP to be defective shall be either repaired or re- Style 401 Cup placed, at TFBP's sole option. TFBP 1/2"Cup.Chrome P/N 1192 neither assumes, nor authorizes any 3/4"Cup.Chrome P/N 1193 person to assume for it, any other ob- 1/2"Cup.White P/N 1196 ligation in connection with the sale of 3/4"Cup.White P/N 1197 products or parts of products. TFBP 1/2"Cup.Brass P/N 1194 shall not be responsible for sprinkler 3/4"Cup.Brass P/N 1195 system design errors or inaccurate or Style 401 Skirt* incomplete information supplied by Specify: Style 401 Skirt with (Chrome, Buyer or Buyer's representatives. White,or Brass)Finish, P/N (specify). In no event shall TFBP be liable, in Style 401 Skirt contract, tort, strict liability or under Chrome P/N 1198 any other legal theory, for incidental, White P/N 1200 indirect,special or consequential dam- Brass P/N 1199 ages, including but not limited to labor "The Cup and Skirt are ordered sepa- charges, regardless of whether TFBP rately for the Style 401 Escutcheon. was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 40 OF ge it"ile15' tqco Fire & Buildings 15 IS ir Products .'4i21w Vail Fire&Emerge y Services I 10/17/16 Technical Services: Tel: (800) 381-9312/ Fax: (800)791-5500 Identification Signs For Sprinkler Systems and Devices NFPA 13 Signing Requirements GeneralWARNINGS Care and The Identification Signs described Description herein must be installed and main Maintenance p tained in compliance with this docu- ment, as well as with the applicable Identification Signs (Ref. Figure 1) are The following inspection procedure designed to provide information to the standards of the National Fire Pro- must be performed as indicated, in ad- end user about the sprinkler system tection Association, in addition to the dition to any specific requirements of and its components. They are avail- standards of any other authorities hav- the NFPA, and any impairments must able with a variety of wording combi- ing jurisdiction. Failure to do so may be immediately corrected. nations to meet the signing require- impair the performance of these ments of NFPA 13. devices. The owner is responsible for the in- The owner is responsible for maintain- spection, testing, and maintenance of The five basic types of Identification their fire protection system and devic- Signs are as follows: ing their fire protection system and de es in compliance with this document, vices in proper operating condition. as well as with theapplicable stan- Type A- Control Valve Sign The installing contractor or sprinkler d Type B- Multi-Purpose Text Signs manufacturer should be contacted Associationsof the National 25),Fire in Protectionddi yp p (e.g., NFPA in addition (See Below) with any questions. to the standards of any authority hav- Type D- Fire Alarm Sign ing jurisdiction. The installing contrac- Type E- Hydraulic Calculation Sign Technical tor or product manufacturer should be contacted relative to any questions. Type B- Identification Signs are avail- Data It is recommended that automatic sprin- able with the following text options: kler systems be inspected, tested, and AIR CONTROL Material&Finish maintained by a qualified Inspection 18 gauge aluminum with mylar facing. Service in accordance with local re- AIR LINE quirements and/or national codes. ALARM TEST Width x Height ANTIFREEZE SYSTEM After placing a fire protection system AUXILIARY DRAIN Inches (mm) in service, notify the proper authorities CONTROL VALVE Type A 9 x 7 (229 x 178) and advise those responsible for mon- itoring proprietary and/or central sta- DRAIN Type B 6 x 2 (152 x 51) tion alarms. DRAIN VALVE Type C 734 x 11/4 (197 x 32) INSPECTION PROCEDURE INSPECTORS TEST Type D 9 x 7 (229 x 178) MAIN CONTROL Annual visual inspections are recom- MAIN DRAIN Type E 5 x 7 (127 x 178) mended to ensure that Identification Signs are properly located. Installation The Identification Signs are provid- ed with 1/8 Inch (3,2 mm) diameter or larger holes(or slots)in the corners for easy attachment using standard hard- ware chain, wire, plastic lock ties, or light gauge metal strap(not included). Page 1 of 4 AUGUST, 2007 TFP1615 tellA OF pi, Page 2 of 4 � C THIS VALVE CONTROLS rgency Services SUPPLY TO AUTOMATIC SPRINKLERS SPRINKLER ' • FIRE - ALARM • i MUST AT BEOPEN TIMES WHEN BELL RINGS TO BE HANDLED ONLY BY AUTHORIZED PERSON OR SY EMPLOYEE CARING FOR SPRINKLER SYSTEM CALL IN CASE OF FIRE n DO NOT SHUT VALVE UNTIL FERE IS ENTIRELY OUT FIRE DEPT OR POLICE WHEN VALVE IS SHUT FOR EMERGENCY-REPAIRS-OR FIRE- NOTIFY: REQUEST DIRECTIONS--RESTORE PROTECTION QUICKLY SIGN- TYPE A, P/N 2300A SIGN- TYPE D RECTANGULAR 6-1/2"X 8-1/2", P/N 2316 OR ROUND 7-1/4"DIAMETER, P/N 2329 • • • HYDRAULIC-SYSTEM • AUXILIARY DRAIN This Building is Protected by a Hydraulically Designed Automatic Sprinkler System SIGN- TYPE B, AVAILABLE WITH THE Location FOLLOWING TEXT OPTIONS "AIR CONTROL" P/N 2328 No. of Sprinklers "AIR LINE" P/N 2302 "ALARM TEST" P/N2304A Basis of Design "ANTIFREEZE SYSTEM" P/N 2306 1. DENSITY GPM/SQ.FT. "AUXILIARY DRAIN" P/N 2307 "CONTROL VALVE" P/N 2310 2. DESIGNED AREA OF DISCHARGE SQ.FT. "DRAIN" P/N 2311 "DRAIN VALVE" P/N 2327 System Demand "INSPECTORS TEST" P/N 2313 "MAIN CONTROL" P/N 2319 1. WATER FLOW RATE GPM "MAIN DRAIN" P/N 2320 2 RESIDUAL PRESSURE AT THE PSt BASE OF THE RISER • i SIGN- TYPE E, P/N 2317 FIGURE 1 IDENTIFICATION SIGNS TFP1615 ' * 0 Limited Ordering 0 � 11 Warranty Procedure Vail Fire&Emergency Services 10/17/16 Products manufactured by Tyco Fire Orders must include the description & Building Products (TFBP) are war- and Part Number (P/N). Contact your ranted solely to the original Buyer for local distributor for availability. ten (10)years against defects in mate Hardware for hanging is not sup- rial and workmanship when paid for plied with the Sign. It must be ordered and properly installed and maintained separately. under normal use and service. This warranty will expire ten (10)years from Identification Signs, date of shipment by TFBP. No warran- (Types A,C, D,or E) ty is given for products or components Specify:Type(A, C, D, or E) manufactured by companies not af- Identification Sign, P/N(specify). filiated by ownership with TFBP or for Identification Signs products and components which have (Type B) been subject to misuse, improper in- Specify: Type B Identification Sign in- stallation, corrosion,or which have not scribed (specify,e.g. "AIR CONTROL"), been installed, maintained,modified or P/N(specify). repaired in accordance with applicable Standards of the National Fire Protec- Type A P/N 2300A tion Association, and/or the standards Type D(Round) P/N 2329 of any other Authorities Having Juris- Type D(Rectangle) P/N 2316 diction. Materials found by TFBP to be Type E P/N 2317 defective shall be either repaired or re- placed, at TFBP's sole option. TFBP Type B neither assumes, nor authorizes any "AIR CONTROL" P/N 2328 person to assume for it, any other ob- "AIR LINE" P/N 2302 ligation in connection with the sale of "ALARM TEST" P/N 2304A products or parts of products. TFBP "ANTIFREEZE SYSTEM" P/N 2306 shall not be responsible for sprinkler "AUXILIARY DRAIN" P/N 2307 system design errors or inaccurate or "CONTROL VALVE" P/N 2310 incomplete information supplied by "DRAIN" P/N 2311 Buyer or Buyer's representatives. "DRAIN VALVE" P/N 2327 In no event shall TFBP be liable, in "INSPECTORS TEST" P/N 2313 contract, tort, strict liability or under "MAIN CONTROL' P/N 2319 any other legal theory, for incidental, "MAIN DRAIN" P/N 2320 indirect,special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Wei OF go- Page 4 of 4 � C Vail Fire&Emergency Services 10/17/16 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 ..."44.. 4.,*15 .a. ., „ix . ri7 tqccs Fire & Building Ista Products Vail Fire&Emerge y Services 10/17/16 Technical Services: Tel: (800) 381-9312 / Fax: (800)791-5500 Sprinkler Cabinets 3, 6, & 12 Sprinklers, 1/2 or 3/4 Inch NPT 6 ESFR Sprinklers, 3/4 or 1 Inch NPT General Description Tyco® Sprinkler Cabinets are con- structed of metal enclosures with _ hinged covers designed to provide on- site storage of an emergency supply of sprinklers and a sprinkler wrench. NFPA 13 requires a representative number of each type of sprinkler used in a sprinkler system to be stored in a - cabinet on-site to allow for immediate -—1111-1111111111111111.1111711111111" removal and replacement of sprinklers that may have operated or become damaged. Sprinkler Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate NPT threaded sprin- klers and are painted an attractive red enamel. WARNINGS Technical The Sprinkler Cabinets described here- Data in must be installed and maintained in compliance with this document, as Material well as with the applicable standards Carbon Steel of the National Fire Protection Asso- Weights ciation, in addition to the standards of any other authorities having jurisdic 3 Sprinkler Cabinet tion. Failure to do so may impair the 1.5 Lbs. (0,68 kg) -40 performance of these devices. 6 Sprinkler Cabinet 2 3 Lbs. (1,04 kg) The owner is responsible for maintain-ing their fire protection system and de- 12 Sprinkler Cabinet1II vices in proper operating condition. 4 0 Lbs. (1,81 kg)The installing contractor or sprinkler 6 ESFR Sprinkler Cabinetmanufacturer should be contacted 3 3 Lbs. (1,36 kg) with any questions. Page 1 of 4 AUGUST, 2007 TFP785 Page 2 of 4 � IP b 55 REMOVE KNOCKOUTS HOLES ACCOMMODATE IgIDj v TO ACCOMMODATE 1/2" NPT SPRINKLERS 3/4" NPT SPRINKLERS Vail Fire&Emergen:y Services 10/17/16 HINGES _s CMI 1-5/16" 5-1/4"R 1 (33,3 mm) (133,4 mm) 7-1/4" 1-1/4" DOOR SWING (184,2 mm) (31,8 mm) 5" 1-1/8" /1 (127,0 mm) (28,6 mm) //I 3-1/4" 2" 2-5/8" 1-3/16" _1_ / 2-9/16" (98,4 mm) (50,8 mm) (66,7 mm) (30,2 mm) / (65,1 mm) 6"(150 mm) ■ MINIMUM HOLES FOR CLEARANCE 3/16"(5 mm) - • I 0 5 SCREWS 1" (127,0 mm) 1-3 " En � (25,4 mm) (44,5 mm) t SPRINKLER SLOTS FOR WRENCH DOOR 1"(25,4 mm) AND HINGES SHELF SHELF STRAP HANGER NOT SHOWN FIGURE 1 3 SPRINKLER CABINET REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 1/2"NPT SPRINKLERS 3/4" NPT SPRINKLERS 1) { il 0 (A) HINGES -=* -r,� ',_') _ I 1 L 1-5/16" 5-1/4" R 1 (33,3 mm) (133,4 mm) 14-1/16" 1-1/4" DOOR SWING (357,2 mm) (31,8 mm) 10-13/16" 1-5/8" I (274,6 mm) --"-x(41,3 mm) / 6"(150 mm) 2" 6" 1-3/16" 2-9/16" 3-1/4" (50,8 mm) (152,4 mm) (30,2 mm) CLEARANUM CE _ / (65,1 mm) (98,4 mm) 1, I f 5" ' 1" (127,0 mm) (25,4 mm) v-+-- (44,5 mm) 1-3/4" 111111111111111111 l HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF SHELF STRAP HANGER NOT SHOWN FIGURE 2 6 SPRINKLER CABINET oti OF go TFP785 � c ,;, Oj Si REMOVE KNOCKOUTS .1691 HOLES ACCOMMODATE 340] TO ACCOMMODATE 1/2"NPT SPRINKLERS 3/4" NPT SPRINKLERS Vail Fire&Emergen:y Services 10/17/16 _ _ L 1-1/2" HINGES `-4-,'`-';, I it �° it ', O O I (38,1 mm) 1-1/2" 5-1/4"R (38,1 mm) (133,4 mm) _ 14-1/16" L 1-1/8" DOOR SWING (357,2 mm) (28,6 mm) ______ 10-13/16" 1-5/8" 17 (274,6 mm) (41,3 mm) 2" 6" 1-3/16" 6"(150 mm) 4 1/8" 3-1/4" (50,8 mm) (152,4 mm) y (30,2 mm) MINIMUM (104,8 mm) (98,4 mm) 1 1 CLEARANCE 1i U I 0 I 1 5" 1" 1-3/4" ,��1111111 (25,4 mm) (127,0 mm) #Y (44,5 mm) v HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF STRAP HANGER SHELF NOT SHOWN FIGURE 3 12 SPRINKLER CABINET REMOVE KNOCKOUTS HOLES ACCOMMODATE TO ACCOMMODATE 3/4"NPT SPRINKLERS 1"NPT SPRINKLERS 1 if f f S% I) Il Il * HINGES - \s . 1 \\--=----i \-= --' L 1-9/16" 6-7/16" R (163,5 mm) I I (39,7 mm) tDOOR SWING _ 14-1/16" 1-9/16" ---------/ (357,2 mm) (39,7 mm) 10-13/16" _ 1-5/8" /1 (274,6 mm) (41,3 mm) i 2" 6" 1-3/16" 7 (180 mm) / 3-1/8" (50,8 mm) (152,4 mm) (30,2 mm) MINIMUM /' (79,4 mm) CLEARANCE ii 3-13/16" • U I ° I (96,8 mm) 1" 6-3/16" igi (25,4 mm) (157,2 mm) 2-3/8" (60,3 mm) 'im� f \ HOLES FOR SPRINKLER SLOTS FOR WRENCH DOOR 3/16"(5 mm) 1"(25,4 mm) AND HINGES SCREWS SHELF STRAP HANGER SHELF NOT SHOWN FIGURE 4 6 ESFR SPRINKLER CABINET Page 4 of 4 � .0 Installation Limited Ordering c, � # Sprinkler Cabinets are designed with Warranty Procedure two 3/16 Inch (4,7 mm) diameter holes ail Fire&Emergency Services for wall mounting or direct attachment Products manufactured by Tyco Fire When placing an order,li?{ gSte the full to the system riser with a strap-type & Building Products (TFBP) are war- product name. Contact your local dis- hanger. The Sprinkler Cabinet should ranted solely to the original Buyer for tributor for availability. be installed at or near the system con- ten (10)years against defects in mate- Sprinkler Cabinet: trol valve and must be stocked with an rial and workmanship when paid for Specify: (Description), P/N (specify). adequate supply of spare sprinklers and properly installed and maintained and a sprinkler wrench. under normal use and service. This 3 Sprinkler Cabinet P/N 1177 warranty will expire ten(10)years from 6 Sprinkler Cabinet P/N 1119 The stock of spare sprinklers should date of shipment by TFBP. No warran 12 Sprinkler Cabinet P/N 1124 include sprinklers of each type and 6 ESFR Sprinkler Cabinet P/N 1111 temperature rating as are installed in ty is given for products or components the sprinkler system, in the following manufactured by companies not of quantities: filiated by ownership with TFBP or for products and components which have Spare been subject to misuse, improper in- Sprinklers In Spstem SpaSdprinklers stallation,corrosion, or which have not been installed,maintained, modified or Under 300 6 repaired in accordance with applicable Standards of the National Fire Protec- 300-1000 12 tion Association, and/or the standards Over 1000 24 of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- The 3, 6, and 12 Sprinkler Cabinets placed, at TFBP's sole option. TFBP are designed to accept both 1/2 &3/4 neither assumes, nor authorizes any Inch NPT threaded sprinklers, where- person to assume for it, any other ob- as the 6 ESFR Sprinkler Cabinets are ligation in connection with the sale of designed to accept both 3/4 & 1 Inch products or parts of products. TFBP NPT threaded sprinklers. As neces- shall not be responsible for sprinkler sary, insert a screwdriver blade from system design errors or inaccurate or the front top of the shelf and under the incomplete information supplied by near bottom part of the knockout an- Buyer or Buyer's representatives. nular ring. Press the screwdriver han- In no event shall TFBP be liable, in dle down to remove the knockout ring. contract, tort, strict liability or under any other legal theory, for incidental, Care and indirect,special or consequential dam- ages, including but not limited to labor Maintenance charges, regardless of whether TFBP was informed about the possibility of The Sprinkler Cabinet, wrench, and such damages, and in no event shall stock of spare sprinklers should be in- TFBP's liability exceed an amount spected at least quarterly. The follow- equal to the sales price. ing items should be checked: The foregoing warranty is made in lieu •The Sprinkler Cabinet should be of any and all other warranties, ex- readily accessible, and not exposed press or implied, including warranties to a corrosive atmosphere or tem- of merchantability and fitness for a peratures in excess of 100°F(38°C). particular purpose. •The stock of spare sprinklers should This limited warranty sets forth the ex- include an adequate number of each clusive remedy for claims based on type and temperature rating. failure of or defect in products, materi- als or components, whether the claim •The stock of sprinklers must be in is made in contract, tort, strict liability good condition. or any other legal theory. •A sprinkler wrench of the appropriate This warranty will apply to the full ex- type must be included in the Sprin- tent permitted by law. The invalidity, kler Cabinet. in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 tellell OF,v. 6000 Series GUARDIAN Flush Fire Dept. Inlet Connections FIRE EQUIPMENT, INC. IS Er: 4 Ftp Residential Function JI oO 8 -._, • Used as auxiliary connections through which the fire departm- F Wail Fire&EmergencyServices can pump water to supplement existing water supplies 10/17/16 lv,. –:;es) ' "1'•' !nil t *' /., • Provides 250 GPM flow(minimum), per 21/2" inlet ti Features/Components 6002 6014/6015 • Single inlet connections incorporate a straight-thru, non-clappered design with female NPT outlets • Two and three-way inlet connections feature brass bodies (angle A' r-: or straight pattern), with integral drop-clapper inlets and female / r NPT outlets -- • Standard components, all connections: 6016/6017 Female hose thread swivel inlets, plugs with chains and identification plate t TA!D.o-1 AuTOI Q ITME I ., - - I • Cast brass construction*, standard *Optional brass finishes on exposed surfaces, add suffix to model no. tl -), . -B Polished;-C Rough Chrome Plated;-D Polished Chrome Plated /i.Nl `@ E• 6024-6029 Single Inlet Connections Back outlet Top/Bottom outlet Model No. 6002 6014 6015 6016 6017 A A �c Outlet 11/2" 21/2" 3" 21/2" 3" Lin L-H-ge � Inlet 11/2"0 "O. "O. 21/2"S "S Plate 41/2"O.D. 7"O.D. 7"O.D. 7"SQ 7"SQ • w Identification Plate Lettering: AUTO SPKR 2'/z"Nipple- 11 Ill Plate 3'h"Dia. (by others) Swivel Inlet----' O . Two and Three-Way Connections g.. Plug 3'/z' _i Model Outlet Size Clappers A B C 7'/," No. 15" = 6024 Back 4" x 21/2" x 21/2" 2 115/8" 77/a" --- 6025 Bottom 4" x 21/2" x 21/2" 2 121/8" 67/8" 71/a" 6026 Top 4"x 21/2" x 21/2" 2 121/8" 67/8" 71/8" 6027 Back 6"x 21/2" x 21/2" 2 115/8" 77/8" --- rliv AUTO SPKR 6028 Bottom 6"x 21/2" x 21/2" 2 121/8" 7" 71/s" 6029** Top 6"x 21/2" x 21/2" 2 121/8" 8" 9" r'r-` 6034 Back 4"x 21/2'x 21/2"x 21/2" 3 173/8" 61/8" 6037 Back 6"x 21/2"x 21/2"x 21/2" 3 173/8" 61/8" --- 6038 Bottom 6"x 21/2"x 21/2"x 21/2" 3 173/8" 75/8" 71/8" 6039 Top 6"x 21/2" x 21/2"x 21/2" 3 173/8" 75/8" 71/8" Identification Plate Lettering: 6034-6039 •AUTO SPKR •AUTO SPKR&STANDPIPE •STANDPIPE • DRY STANDPIPE Back Outlet Top/Bottom Outlet A A-7 Tcl. **Available with steel body& clapper snoots only 4111P. 411111. 0 2'/2"Nipple (by others)er ` r Plate 3'/'Dia. S Inlet W W W Notes 0 • g • Pipe nipples for connecting bodies to swivel inlets by others Plug 3'/z' m MP L • Always specify hose threads and identification plate lettering z3" 65/8 • Contact factory for current UL listing/FM approvals and special requirements I OF NIBCC" WWW • AHEAD OF THE FLOW- C wit 4.71 200 lb. WWP Bronze Check Valves 0,, De Fire Protection Valve • Horizontal Swing • Rubber Disc Rei Vail Fire&Emergency Services 10/17/16 200 PSI/13.8 Bar Non-Shock Cold Water 1 �f • CONFORMS TO MSS SP-80 'he' MATERIAL LIST PART SPECIFICATION KT-403-W 1. Bonnet Bronze ASTM B 62 Threaded or B 584 Alloy C84400 2. Body Bronze ASTM B 62 or B 584 Alloy C84400 3. Hinge Pin Bronze ASTM B 140 Alloy C31400 or B 134 Alloy C23000 4. Disc Hanger Bronze ASTM B 62 5. Hanger Nut Bronze ASTM B 97 Alloy C65500 or Brass ASTM B 16 6. Disc Holder Bronze ASTM B 62 7. Seat Disc Buna-N(W) TFE(Y)# 4 O Q n 8. Seat Disc Nut Brass ASTM B 16 or B 97 Alloy C65500 \ ' 1h 9. Hinge Pin Plug Bronze ASTM B 140 Alloy C32000 0 „�00 (Not Shown) *10. Seat Disc Washer Stainless Steel 0 t '_ \1RRR Stalk 1$4, *Sizes 3/a',1",11/"and 11/2"only. B min �` 11111111111#21/2"and 3"size only. IIINIImr �► 0 IIIINIIIII� 'l1ll A DIMENSIONS-WEIGHTS-QUANTITIES KT-403-W Dimensions NPT x NPT Size A B Weight Box Master. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn.Qty. 1/2 15 2.44 62 1.69 43 .58 .26 10 50 3/4 20 2.94 75 1.88 48 .92 .42 10 50 1 25 3.56 90 2.31 59 1.55 .70 5 30 11/4 32 4.19 106 2.69 68 2.32 1.05 5 20 11/2 40 4.50 114 2.94 75 3.00 1.36 2 10 2 50 5.25 133 3.81 97 4.87 2.21 2 10 21/2 65 8.00 203 5.06 129 11.48 5.22 1 5 3 80 9.25 235 6.25 159 17.53 7.97 1 4 Sizes 21/2'and 3"supplied as T-433-Y with TFE seat disc. NIBCO check valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. WARNING-Valve must be installed downstream of receiver tank if used in line with reciprocating air compressor. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 14 TECH SERVICES PH:1.888.446.4226•FAX:1.800.234.0557•INTERNATIONAL OFFICE PH:+1.574.295.3221 •FAX:+1.574.295.3455 www.nibco.com