HomeMy WebLinkAboutF16-0015 Data Cut Sheets.pdf SECTION IV - SYSTEM DESIGN UL EX.3470 7-1-09 Page 4-28 REV. 6 NOZZLE PLACEMENT REQUIREMENTS(Continued) Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping #OF FLOW Hazard Dimensions Quantity Heights Part No. Flow No. NOZZLES POINTS Duct or Transition(Single Length-Unlimited 1 - 419336 Nozzle) Perimeter-50 in.(127 cm.) Diameter-16(40.6 cm) Duct or Transition Length—Unlimited 1 - 419337 2W (Single Nozzle) Perimeter-100 in.(254 cm) Diameter-31 7/8 in.(81 cm.) Duct or Transition Length-Unlimited 2 - 419337 2W (Dual Nozzle) Perimeter-150 in.(381 cm.) Diameter-48 in.(122 cm.) Electrostatic Precipitator individual Cell 1 - 419334 1/2N (At Base of Duct) .-_ Plenum Length—10 ft.(3 m) 1 - 419335 IN ,w,,,w ..--•t - "-. (Horizontal Protection) Length- 6 ft.(1.8m) 1 419336 1W Plenum Length-4 ft.(1.2 m) 1 - 419336 1W (Vertical Protection) Width-4 ft. (1.2 m) Fryer/Split Vat Fryer" Maximum Size (without drip board) 15 in.(38 cm)x 14 in(36 cm) High Proximity 1 27-47 in. 419339 230 Medium Proximity 1 20-27 in. 419340 245 Maximum Size .- (with drip board) 21 in. (53 cm)x 14 in.(36 cm) Fry Pot must not exceed 15 in x 14 im High Proximity 1 27-47 in. 419339 230 Medium Proximity 1 20-27 in. 419340 245 'Ilse 2WH noe ..Foron 1.5 gni lau 6 flon',Mow en pleuwa promioa sooty. r multiple nozzle protection orsingle tryeq see detailed iofoneaeoa on Pages 4-101 through 4-10 8 SECTION IX - APPENDIX TOTAL FLOW POINTS: " UL EX.3470 7-1-09 Page 9-1 REV.6 SYSTEM SELECTION GUIDE TOTAL TANK TYPE OF NITROGEN CARBON DIOXIDE FLOW NO)* QUANTITY SYSTEM TYPE OF HARDWARE CARTRIDGE REQUIRED CARTRIDGE REQUIRED 15 f 1 Single 1.5 Gal.Reg.Release LT-20-R(7032) 101-10(15850) 6-11 1 Single 3.0 Gal.Reg.Release LT-30-R(5373) 101-20(17492) 12-16 2 Double 1.5 Gal.Reg. Release Double(73022) 101-30(15851) 3.0 Gal.Additional Tank 17-22 2 Double 3.0 Gal. Reg.Release Double(73022) 101-30(15851)** 3.0 Gal.Additional Tank 23-27 3 Multiple 1.5 Gal.Reg. Release LT-20-R (7032) 101-10(15850) 3.0 Gal.Reg.Actuator LT-A-101-30 (29187) 101-30(15851)*** 3.0 Gal.Additional Tank 28-33 3 Multiple 3.0 Gal.Reg.Release LT-30-R (5373) 101-10(15850) 3.0 Gal.Reg.Actuator LT-A-101-30 (29187) 101-30(15851)*** 3.0 Gal.Additional"tank 34-38 4 Multiple 1.5 Gal.Reg.Release Double(73022) 101-30(15851) 3.0 Gal.Additional'rank 3.0 Gal.Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal..Additional Tank 39-44 4 Multiple 3.0 Gal. Reg.Release Double(73022) 101-30(15851)** 3.0 Gal.Additional Tank 3.0 Gal.Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal.Additional Tank 45-49 5 Multiple 1.5 Gal.Reg.Release LT-20-R(7032) 101-10(15850) 3.0 Gal.Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal.Additional 3.0 Gal Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** '., 3.0 Gal.Additional Tank 50-55 5 Multiple 3.0 Gal.Reg.Release L r-30-R (5373) 101-20(17492) - . 3.0 Gal.Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal.Additional Tank ' 3.0 Gal.Reg.Actuator LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal:Additional Tank 56-60 6 Multiple 1.5 Gal.Reg.Release 3.0 Gal.Additional Tank Double (73022) 101-30(15851) 3.0 Gal.Reg.Actuator 3.0 Gal.Additional Tank LT-A-101-30(29187) 101-30(15851)*** 3.0 Gal.Reg.Actuator 3.0 Gal.Additional Tank LT-A-101-30 (29187) 101-30(15851)*** 61 -71 7 Multiple 3.0 Gal. Reg. Release 3.0 Gal.Additional Tank Double(73022) 101-30(15851) 3 0 Gal-Reg-Actuator 3.0 Gal.Additional Tank LT-A-101-30 (29187) 101-30(15851)*** 3.0 Gal:Reg.Actuator 3.0 Gal.Additional Tank LT-A-101-30 (29187) 101-30(15851)*** *Based on 5 flow numbers for a 15 gal sslom and 11 flow numbersfor a 30 pal.arvbien Sccpogoo 3O and 4-31 for ex.lions *311looks am mainfolded,only a-double lank"nitrogen au-fridge(Part No.73)22)can be used. *001ferks are mmdfalded 000113 an LT-A-101.30 mIroscn cartridge(Pan No.19187)can be used. SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-1 7-1-09 REV.8 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R-102 Restaurant Fire Suppression System may be 1.Nozzles must be located 2-8 in.(5-20 cm)into the center of the used on a number of different types of restaurant cooking appli- duct opening,discharging up.See Figure 1. ances and hood and duct configurations.The design information listedisin this sectionddeals with the s and parametersn this pre-engineered system.Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. 2—e IN. (5-20 cm) • Both systems must actuate simultaneously. t • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. 000173 • Adjacent appliances requiring protection must be protected 2.In installations where a UL listed damper assembly is with the same type of system, either R-102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in. unless the center-to-center spacing between the adjacent (20 cm) maximum,to a point just beyond the damper assem- R-102 and PIRANHA nozzles is no less than 36 in.(91.4 cm). bly that will not interfere with the damper.Exceeding the maxi- • When appliances are protected with R-102 nozzles, the hood mum of 8 in.(20 cm) In this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3.Previously listed 3 flow number and 5 flow number duct pro- • Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No.418087- One of the key elements for restaurant fire protection is a correct 06,can also still by utilized. system design.This section is divided Into ten sub-sections:Noz- DUCT SIZES UP TO 50 IN.(127 cm) zle Placement Requirements,Tank Quantity Requirements, Actu- PERIMETER/16 IN.(41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- • One 1W nozzle(Part No.419336)=one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri- - 50 in.(127 cm)perimeter maximum cal Gas Valve Requirements, Electrical Switch Requirements,and Pressure Switch Requirements. Each of these sections must be • 16 in.(41 cm)diameter maximum completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN.(254 cm) during installation. PERIMETER/32 IN.(81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle(Part No.419337)=two flow numbers This section gives guidelines for nozzle type, positioning, and • 100 in.(254 cm)perimeter maximum quantity for duct,plenum,and individual appliance protection.This . 32 in.(81.3 cm)diameter maximum section must be completed before determining tank quantity and piping requirements. The chart below shows the maximum protection available from - -- each duct nozzle. Duct Protection—Single Nozzle ) Part 3.0 Gallon 1.5 Gallon All duct protection is UL listed without limitation of maximum duct Description No. System System length (unlimited length).This includes all varieties of ductworks 2W Nozzle 419337 Maximum Maximum both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. 100 in.(254 cm) 100 in.(254 cm) The R-102 system uses different duct nozzles depending on the Perimeter Perimeter �3R size of duct being protected. ?1W Nozzle 419336 Maximum Maximum 50 in.(127 cm) 50 In.(127 cm) Perimeter Perimeter SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-5 7-1-09 REV.5 Plenum Protection The R-102 system uses the 1W Nozzle (Part No.419336)or the '.. 1N Nozzle(Part No.419335)for plenum protection.The 1W noz- zle tip is stamped with 1W and the 1N nozzle tip is stamped with MAlXiMU cm) 1 N, indicating they are one-flow nozzles and must be counted as i one flow number each.When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. ii, 1 INIcm) MINIMUM VERTICAL PROTECTION—GENERAL '1W NOZZLE — PART NO. 419336 — SINGLE AND"V" BANK 'PROTECTION :n 201N.(51 cm) One 1W nozzle will protect 4 linear feet (1.2 m) of plenum.The MAXIMUM maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft(0.6 m).After the first nozzle,any t additional nozzles must be positioned at a maximum of 4 ft(1.2 m) iv. 1 IN.(2.5 cm) apart down the entire length of the plenum.The plenum width must MINIMUM not exceed 4 ft(1.2 m).(The 1W nozzle can be used on single or �'P'..- V-bank filter arrangements.)See Figure 6. FIGURE 7 000190 2 FT(0.6 m) MAXIMUM .e Option 2:The 1W nozzle must be placed perpendicular, 8-12 in. M XIMUM) (20-30 cm)from the face of the filter and angled to the 4 FT(1.2 m) ...----------.‘,-.,4 FT(1.2 m) center of the filter.The nozzle tip must be within 2 in. 2 FT(0.6 m)MAXIMUM oil MAXIMUM (5 cm) from the perpendicular center line of the filter. MAXIMUM - � See Figure 8. y�Y 111100;,......"7-‘,* I<spiel I� 121N.(30 cm) MAXIMUM ir 41N. Ai -. 7h0 cm)►` /I I�i, BIN.(20 am) MINIMUM \, /� NOZZLE TIP t MUST BE WITHIN FIGURE 6 THIS AREA 6;% 110019] When protecting plenums with the 1W nozzle,two options of coy- , erage are available: FIGURE 8 Option 1:The 1W nozzle must be on the center line of the single 11oaw11 or "V" bank filter and positioned within 1-20 in. ,' HORIZONTAL PROTECTION—OPTION 1 (2.5-51 cm) above the top edge of the filter. See ' 1N NOZZLE—PART NO.419335—SINGLE BANK PROTECTION Figure 7. One 1N nozzle will protect 10 linear feet(3.1 m)of single filter bank plenum.The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm)from the face of the filter, centered between the filter height dimension, and aimed down the length.The nozzle must be positioned 0-6 in.(0-15 cm)from the end of the hood to the tip of the nozzle.See Figure 9. • I / 2-4N. 10 FT(3.1 m) (5-10 cm) MAXIMUM 000201 000202 FIGURE 9 V, r""^'F"M x: "ar�asmnvy .0 _ oz's .a >3 &yfi '.� il- $ 3 SIRESUP ION sYST S 4 b,Tr Firn5wp° dA&B&t lYneucn �' >'�- -e - Datafspecthcattons sr y say .... 7 Low pH Agent 1s Proven Design -�--` '-3 Reliable Gas Cartridge Operation 4. u Aesthetically Appealing UL Listed —Meets Requirements of UL 300 ULC Listed—Meets Requirements of ULC/ORD-C1254.6 n CE Marked S 0 The ANSULe R-102714 Rest urant Fire Suppression System is an auto- matic,pre-engineered,fire suppression system designed to protect A `w" ,-t . areas associated with ventilating equipment including hoods,ducts, f- —:r OBC92 plenums,and filters.The system also protects auxiliary grease extrac- tion equipment and cooking equipment such as fryers;griddles and » "„ < range tops; upright,natural charcoal,or chain-type broilers;electric,lava rock,mesquite,or gas-radiant char-broilers;and woks. The system is ideally suitable for use in restaurants,hospitals,nursing homes,hotels,schools,airports,and other similar facilities. A system owner's guide is available containing basic information Use of the R-102 system is limited to indoor applications or locations pertaining to system operation and maintenance.A detailed technical that provide weatherproof protection within tested temperature limita- manual,including system description,design,installation,recharge and Sons.The regulated release and tank assemblies must be mounted in resetting instructions,and maintenance procedures,is available to qual- an area where the air temperature will not fall below 32°F(0°C)or lied individuals. exceed 130`F(54°C).Thesystemmust be designed and installed The system is installed and serviced by authorized distributors that are within the guidelines of the UUULC Listed Design,Installation, - trained by the manufacturer. Recharge,and Maintenance Manual. The basic system consists of an ANSUL AUTOMANre regulated release assembly which includes a regulated release mechanisni.and a wet- chemical storage tank housed within a single enclosure,Noz2les with ^ 'T 'rye,:: "'7 ':`- blow-off caps,detectors,cartridges,agent,fusible links,and pulley &YS7Yz1- 4FHP716N elbows are supplied in separatepackages in the quantities needed for The restaurant Tire suppression system is a pre-engineered,wet chemi- fire suppression system arrangements.cal,cartridge-operated,regulated pressure type with a fixed nozzle Additional equipment includes a remote manual pull station(s),mechan- agent distribution network.It is listed with Underwriters Laboratories,Inc. ical and electrical gas valves,and electrical switches for automatic (UUULC). equipment and gas line shut-off.Accessories can be added such as alarms,warning lights,etc.,to installations where required. . .. ? Additional tanks and corresponding equipment can be used in multiple arrangements to allow for larger hazard coverage.Each tank is limited _ 0 - to a listed maximum amount of flow numbers. s g fe r z-� ,y4dJ 00._15 The system is capable of automatic detection and actuation as well as remote manual actuation.Additional equipment is available for building fire alarm panel connections,electrical shutdown and/or interface,andmechanical or electrical gas line shut-off applications. The detection portion of the fire suppression system allows for auto- matic detection by means of specific temperature-rated alloy type fusible links,which separate when the temperature exceeds the rating of the link, allowing the regulated release to actuate. 9 • SECTION Ill—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-1 7-1-09 REV.6 EXTINGUISC{ING AGENT ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon—Part No. "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon—Part No.79372)is a potassium-based solu- (MECHANICAL) ton designed for fast knock-dawn and suppression of grease- related fires.The agent is shipped in plastic containers which pro- NOTE:AGENT TANK MUST BE vide one complete charge.tank chare.(Refer to Section V,Page OR SEE D 5-2.1,for ORDERED GE 3-4 EP3-4ATELY - o o maximum agent fill capacity.) Agent storage life expectancy is / twelve years and can be stored at a temperature of—40°F to 130 RELEASE e°F(-40°C to 54°C).Note:When Installing agent in R-102 sys- MECHANISM v—,z1 Ricers, temperature range is 32 °F (0°C) to 130 °F (54°C).The III —"IIS distributor must record the batch numbers and date of shipment receipt to be filed with each installation record. Qh "ANSULEX"LOW pH LIQUID FIRE SUPPRESSANT , f r -3/41. 11111110 __. / REGULATOR ar\\.._ '` / �. SHIPPING WT.25 L6(11 kg) \ • �- 3.0 GALLON 1.5 GALLON 00013B SHIPPING WT.35 LB(16 kg) SHIPPING W.19 LB(9 kg) 000139 000137 FIGURE 1 REGULATED RELEASE ASSEMBLY(ELECTRICAL) The ANSUL AUTOMAN Regulated Electrical Release Assembly REGULATED RELEASE ASSEMBLY(MECHANICAL) (Part No.429856) is identical to the mechanical version except it also contains a factory installed 120 VAC solenoid and electrical The ANSUL AUTOMAN Regulated Mechanical Release Assembly switch. (Part No. 429853) contains the regulated release mechanism, The solenoid is used to provide electrical actuation of the release expellant gas hose for agent tank hookup, and enclosure knock- mechanism.The electric switch is used to protect the solenoid by outs to facilitate installing actuation piping;expellant piping;detec- opening the circuit to the solenoid once the system is fired. tion system; and additional equipment. This regulated release Additional electrical switches can be added as required for auto- assembly is used in single,double,and multiple-tank systems and matte equipment and gas shut-off accessories,as well as initiating must be mounted to a rigid surface.The release mechanism can audible and visual alarms. be used to interconnect both the actuation and expellant gas lines as required per system design.The regulator is designed to allow "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY a constant flow of gas into the tank at 110 psi(7.6 bar)when the (ELECTRICAL)° system is actuated.The agent tank must be ordered separately. In single, double, and multiple-tank systems,the provided expel- Noce AGENT TANK MUST BE ORDERED 'ant gas hose connects the agent tank to the bottom outlet of the SEPARATELY o regulator. In double and multiple-tank system configurations, the OR SEE PAGE3-4 _ back outlet of the regulator is used as an expellant gas feed for 11 one additional tank-enclosure or tank-bracket hookup.The enclo- REGULATOR -1 sure contains the required knockouts to facilitate this connection. �� �'' < swlrcH If a pressure switch is to be attached to the regulator,additional fit- tings are required. - - The tank is mounted within the enclosure.The tank contains an adaptor/tube assembly with a burst disc union. The burst disc soLENOIo helps prevent siphoning of the agent up the pipe due to significant temperatureisstainless lless tiein the nde where mthe tank is ted.The sank is stainless steel and, under normal conditions, requires hydrostatic testing every twelve years. 1 ,.1 The detection and additional equipment required per system designtaiare connectednuto tothe release on mechanism.The enclosureku . SHIPPING war 34 Le(13 kg) contains knockouts to facilitate detection and additional hookups. \\\\\_\_f( The system can be actuated automatically or manually.Automatic actuation occurs when a fusible link within the detection system FIGURE 3 separates in a fire condition. Manual actuation of the system Dorms occurs when personnel pull on the remote manual pull station -NOTE:ANSUL AUTOMAN Regulated Electrical Release,Part No.429856,is not pull ring. intended to be used With electric detection. SECTION UI—SYSTEM COMPONENTS UL EX3470 ULO EX3470 Page 3-3 4-1-06 REV.3 AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY The agent tank shipping assembly (3-Gallon, Part No. 429862, The OEM Regulated Actuator Assembly, Part No. 418691, and 1.5 Gallon, Part No.429864)consists of a stainless steel tank includes the regulator,pneumatic actuator,expellant gas hose and and an adaptor/tube assembly.The adaptor/tube assembly con- OEM bracket. Also available is an OEM Regulated Actuator tains a burst disc.The burst disc prevents agent leakage due to Assembly with all the above mentioned components except for the significant temperature fluctuations in the area where the tank is bracket.This assembly is Part No.418522. located. Under normal conditions, the tank requires hydrostatic testing every twelve years.The date of manufacture is stamped on !I the tank nameplate. The tank is shipped uncharged and must be filled with only ANSULEX Low pH Liquid Fire Suppressant during installation. "-�\� I ei ,,_.,-QTANK ADAPTOR.' ) TUBE ASSEMBLY 3 GALLON SHIPPING WT. 7 LB(3 kg) 1.5 GALLON AGEN SHIPPING WT. 5 LB(2 kg) SHIPPING WT.4 LB(2 kg) TANKT P FIGURE 10 Onzs TWO TANK ENCLOSURE ASSEMBLY . FIGURE 8 The Two Tank Enclosure Assembly, Part No.429872, consists of , °°°'°° two expellant gas hoses,two grommets, and the mounting enclo- OEM RELEASE/BRACKET ASSEMBLY sure.The assembly is used in 9 gallon systems.It can be coupled (FOR OEM IN-CABINET USE ONLY) with a 3-gallon regulated release assembly or a 3-gallon regulated actuator assembly to give a total of 9 gallons of agent.Agent tanks The OEM Regulated Mechanical Release/Bracket Assembly, Part must be ordered separately. No. 79493, contains the same regulated release mechanism as The tank enclosure is designed to mount in a minimum amount of the standard ANSUL AUTOMAN Regulated Release.Assembly. space. The OEM Regulated Electrical Release/Bracket Assembly, Part .No.418054`, is identical to the mechanical version except it con- tains a factory installed 120 VAC solenoid and electrical switch. These release/bracket assemblies must be installed in a suitable equipment enclosure either horizontally or vertically.They contain all the necessary mounting and conduit holes needed to fully install the assembly.The agent tank is installed separately and swr. PPINGw .1% need not be bracketed once it is piped and filled. Note:OEM zs Las(iz kg) Release/Bracket Assembly must be installed high enough in cabi- net so that there is sufficient room to install and remove cartridge. 0-'Note:OEM Regulated Electrical Release/Bracket Assembly,Pat No.418054,is n not intended to be used with electric detection. oh c-._ ytth\> �r aFIGURE 11 MOUNTING0°2277 RELEASE - BRACKET MECHANISM ' 0 a REGULATOR ''. llp ' - y SHIPPING WT. IDLE(S kg) P FIGURE 9 05144 • SECTION(11—SYSTEM COMPONENTS • UL EX3470 ULC EX3470 Page 3-5 7-1-09 REV.3 GAS CARTRIDGES NOZZLES The R-102 system uses gas cartridges to store nitrogen or carbon There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the system is actuat- ute the liquid agent in a uniform pattern throughout the hazard ed,at which time the cartridge seal is punctured and the released area: gas expels liquid agent from one or more tanks through the dis- 1. 1W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. 2. 1 N Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dioxide gas car- 3. 1/2N Nozzle 9. 290 Nozzle fridges are available as shown in Figure 13. 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC/DOT are both Transport Canada(TC) and 5. 2W Nozzle 11. 1F Nozzle Department of Transportation (DOT) approved. Cartridges noted 6. 230 Nozzle as DOT are Department of Transportation approved only. Although these nozzles are similar in appearance and have Cartridge selection options are provided in Section IV under Tank certain common parts, the tip of each nozle is designed for a and Cartridge Requirements. specific application and must only beused in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV — System Design, for • individual nozzle usage. I.. 3/6-18 NET FEMALE THREAD t y p 17 1/41N. .— a. fr. 1 Y 5/6 IN. (43.8 cm) 77/3 IN. (29,5 cm) 121/4 < INTERNAL CUP N(20 cm) (31.1 STRAINER INSIDE X- K a� BL WOFOR r1<� CAPLOFF Man {/ 21/2 IN. 2112IN. (10.6 c N. 3(9/16cm) N. LOOP {yt`q/�"B'p- VENDOR (6.4 cm) (6.4 cm) (10.6 cm) (9 cm) /--q' 1 CODE LT-20-R LT-30-R DOUBLE-TANK LT-A-101-30 NOzzLE" ,Y (IF PRESENT CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE STAMPING 000148 000141 000147 400140 • CARSON DIOXIDE CARTRIDGES f IGUR o oA 02 Nozzle Identification Chart Note:See Component Index for nozzle package shipping assem- tii,_, I. _ N bly part numbers. I 11 sre IN. Nozzle 91N. 77/6 I. (29.5`m) Nozzle Nozzle Nozzle` Flow (229 (20 cm) s-Type Part No. Stamping No. Nozzle Material I 1 �� e 1W Nozzle 419336 1W** 1 Chrome-Plated Body • � �I ® iN Nozzle 419335 1N`* 1 Chrome-Plated Body 21N. 21/21N. 21/2 IN. 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body (5.1 cm) (6.4 cm) (6.4 cm) o,- 3N Nozzle 419338 3N 3 Chrome-Plated Body 101-10 CARTRIDGE 101-20 CARTRIDGE 101-30 CARTRIDGE 000149 000100 000151 2W Nozzle 419337 2W 2 Chrome-Plated Body FIGURE 13 230 Nozzle 419339 230 2 Chrome-Plated Body Additional cartridge shipping assemblies are available for 245 Nozzle 419340 245 2 Chrome-Plated Body European and Australian requirements. 260 Nozzle 419341 260 2 Chrome-Plated Body sCartridge European Australian TC/DOT 290 Nozzle 419342 290 2 Chrome-Plated Body Description Part No. Part No. Part No. 2120 Nozzle 419343 2120 2 Chrome-Plated Body LT-20-R 428440 428948 423429 1F Nozzle 419333 1F . 'r.fi'-- - Chrome-Plated Body LT-30-R 428441 426553 423435 'Nozzle stamping may contain an additional letter indicating a vendor's code. Double Tank 428446 426563 423493 s"Stainless steel versions are available in the 1W nozzle(Part No.432527)and _ A Ana9 42_G6SS d2;a91 0- the IN nozzle(Part No.435672). 101-10—CO2 428443 N/A 423439 SILICONE LUBRICANT 101-20—CO2 428445 N/A 423441 Dow Corning Compound 111, Part No. 78112, is available in a 101-30—CO2 428444 N/A 423443 5.3-ounce tube.Compound has excellent qualities for sealing and eNote: For 101-10 cartridge, Part No.15850 is DOT only. lubricating system components. SEC T[ON [[I—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-6 REV 7 7-1-09 SWIVEL ADAPTOR CONDUIT OFFSET ASSEMBLY The Swivel Adaptor Assembly consists of a swivel nut,swivel body E The conduit offset assembly, Part No. 435961, is used to change and swivel balL All are chrome-plated.The swivel adaptor allows direction of the wire rope on detection,mechanical gas valve,and any nozzle to be rotated approximately 30°in all directions.Swivel remote pull station lines.The conduit offset assembly can only be Adaptors must be ordered as a Swivel Adaptor Shipping used in the area where the conduit attaches to the regulated Assembly, Part No.423572,which contains 25 Swivel Adaptors or release assembly. When using the conduit offset assembly, the >Part No.419385,which contains 9 Swivel Adaptors. maximum number of pulley elbows is still allowed.The Conduit -Offset Shipping Assembly, Part No.436063, consists of 6 conduit a 3/8-18 NPT offsets. FEMALE THREAD CONDUIT ii`— COUPLING.ND ti 3/3-13 NPT CONDUIT a MALE THREAD OFFSET 3D DEGREE ROTATION FIGURE 15 000003 CONDUIT RUBBER BLOW-OFF CAPS CONNECTOR (1frE .The Rubber Blow-Off Cap helps keep the orifice of the nozzle free of grease or other substances that could interfere with agent dis- tribution.A retaining strap attaches the blow-off cap to the nozzle. FIGURE 18 Rubber Blow-Off Caps must be ordered as a Shipping Assembly, 000153 -Part No. 77695, which contains 50 blow-off caps, or Part No. -77411,which contains 12 blow-off caps. "Gila-SEAL'ADAPTOR The`Quik-Seal"adaptor is a listed mechanical bulkhead fitting that produces a liquid-tight seal around both distribution piping and detection conduit which runs through restaurant hoods and ducts. ~ � ; The 'Quik-Seal" adaptor accepts threaded pipe or conduit. The r adaptor is available for 1/4 in.(Part No.78196), 3/8 in. (Part No. 77285),1/2 in.(Part No.77287),or 3/4 in.(Part No.77289)pipe or I conduit sizes.When using with EMT conduit, a conduit connector must be installed in each end of the adaptor. The "Quik-Seal" lit a Adaptor Shipping Assembly must be ordered as stated below: it a Shipping I FIGURE0013Assembly Hole Size 0009 Size Part No. Qty. Required CB METAL BLOW-OFF CAP 1/4 in. 78196 24 3/4 in. The CB Metal Blow-off Cap Package,Part No.433208,is used for 3/8 in. 77285 24 1 1/8 in. all high temperature environments.The metal blow-off cap con- 1/2 in. 77287 24 1 1/8 in. tains a special 0-ring placed inside the cap which integrates with 3/4 in. 77289 24 1 3/8 in. the nozzle to create a seal and to help hold the blow-off cap in is. position. ADAPTOR BODY The CB Metal Blow-Off CapPackage, Part No.433208, �—GASKET contains ,3., _. LOCK\NABHER 10 blow-off caps. Also available is a 10 pack of CB Stainless Steel Blow-Off Caps, NUT Part No.434707. - > >A 10 pack of Metal Blow-Off Cap O-rings, Part No.551530,is also FIGURE 19 1.-available. 154 STAINLESS STEEL WIRE 6 METAL CAP FIGURE 17 037833 SECTION[[I—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-7 7-1-09 REV 6 "COMPRESSION-SEAL ADAPTOR .COCKfiNG LEVER/LOCK BAR This adaptor is a mechanical bulkhead fitting that produces a The cocking lever is a component required to cock(arm)both the liquid-tight seal around pipe and conduit when installing distribu- mechanical/electrical ANSUL AUTOMAN release and the mach- tion piping and detection conduit through restaurant hoods and anical gas valve.After the ANSUL AUTOMAN is cocked(armed), ducts. The "Compression-Seal" adaptor is a straight-through the lock bar must be inserted to eliminate the accidental firing of design requiring no cutting or threading of conduit or pipe.The the release mechanism.These components are available as either .adaptor is available for pipe sizes of 1/4 in.(Pad No.79149),3/8 in, an individual shipping assembly or a shipping assembly containing (Pad No.79151),1/2 in.(Pad No.79147),and EMT conduit size of both. Listed below are the various shipping assembly part num- .1/2 in. (Part No. 79153). Each "Compression-Seal" Adaptor bets. Shipping Assembly must be ordered as stated below: Part No. Description Shipping Assembly Hole Size 435603 Short Handle Cocking Lever only Size Part No. Qty. Required (Mechanical/Electrical ANSUL AUTOMAN) 1/4 in.Pipe/1/2 in.tube 79149 24 3/4 in. 435790 Short Handle Cocking Lever with Lock Bar 3/8 in. Pipe/5/8 in.tube 79151 24 1 1/8 in. (Mechanical/Electrical ANSUL AUTOMAN) 1/2 in.Pipe 79147 24 1 1/8 in. 14995 Long Handle Cocking Lever only 1/2 in.EMT Conduit 79153 24 1 1/8 in. (Mechanical/Electrical ANSUL AUTOMAN) - 15618 Long Handle Cocking Lever with Lock Bar < COMPRESSION NUT (Mechanical/Electrical ANSUL AUTOMAN) 26310 Cocking Lever only(ANSUL AUTOMAN Il-C) ^ ADAPTOR BODY GASKET -.,.,..w,„-.,._,..,,,,. .,. „ LOOKWASHER 415018 Cocking Lever only(Mechanical Gas Valve) NUT 14985 Lock Bar ” FIGURE 20 Short Handle Cocking Lever 0°mS "HOOD SEAL'ADAPTOR ASSEMBLY This adaptor is a mechanical bulkhead fitting that produces a .*liq- u id-tight seal around 1/2 in.EMT conduit when installing the detec- _ tion line through restaurant hoods and duct.The adaptor accepts - a high temperature pulley elbow and, when used, correctly posi1111411111111111111%.* - tions the elbow or conduit in line with the conduit adaptor hole in the detector bracket.The"Hood Seal"eliminates the need for mul- tiple elbows when penetrating the top of a hood when installing the *Requires a crescent wrench or open end/box wrench detection line."Hood Seal"Adaptors,are available in quantities of 6 as Shipping Assembly Part No_423253. Long Handle Cocking Lever NUT SEAL BM /SEAL WASHER. .>r ADAPTOR .. - BODY . '1=M= GASKET PULLEY O (NOT ELBOW JII VI!' OF ASSEMBLY) Lock Bar USE ONLY PULLEY ELBOW,PART N0.423253 FIGURE 21 comes .REDUCING COUPLING The reducing coupling,Part No.436228,is made of stainless steel material with 3/8 in.x 1/2 in.NPT inlet threads. If necessary,the -- reducing coupling can be utilized when installing the Agent r Distribution Hose Line Kit, Part No. 435982.Tiara couplings are FIGURE 23 required per Agent Distribution Hose. 008225 1/41N. �—(3.3 cm) b. cis ow)(3.D cm)v1 FIGURE 22 °°o_A SECTION tit—SYSTEM COMPONENTS UL 6X3470 ULC 6X3470 Page 3-8 REV.8 7-1-09 DETECTORS PULLEY TEE The detector consists of three basic components:the bracket,link- The Pulley Tee (Part No.427929) is used to change the direction age, and fusible link. (Fusible links are not included and must he of two wire ropes by 90°.It must be used in areas where the tern- ordered separately.)The bracket holds the entire assembly to the peratures are within the range of 32°F to 130°F(0`C to 54°C). mounting surface.The linkage is used to support the fusible link. Pulley tees can be used in mechanical gas valve actuation lines The fusible link is designed to separate at a specific temperature and remote manual pull station lines. Pulley fees cannot be used and release the wire rope,thereby actuating the regulated release within a detection line. mechanism. r The scissor style detector allows the wire rope to be strung corn- -- pletely through the detection system conduit and brackets first and O O the detector linkage assemblies are then clipped on later. I r The detector consists of two types of assemblies: 11.9r TheTerminal Detector(Part No.435546)includes a test link and is placed last in a series of detectors.This detector is sometimes > referred to as the end-of-line detector and is thus named because FIGURE 26 00447 26 it is at the point at which the wire rope"terminates,'or is anchored at the detector bracket.Only one terminal detector is required per STAINLESS STEEL CABLE defection system. The 1/16 in.stainless steel cable is run from the terminal detector, r The Series Detector(Part No.435547)is any detector located in- through conduit, all series detectors and pulley elbows, and into line between the regulated release assembly and the terminal the regulated release mechanism trip lever.When any fusible link r detector. separates, the tension on the cable is relaxed, and the trip lever ®When using Part No.435546 and 435547 detectors, a total of 15 actuates the regulated release mechanism.The cable can also be detectors can be in one detection system:14 series detectors,Part used for mechanical gas valves and remote manual pull stations. -No.435547 and 1 terminal detector, Part No.435546. The cable is available in 50 ft(15 m) (Part No. 15821) and 500 ft (152.4 m) (Part No.79653)lengths. I-Note:Series Detector, Part No.435547, is also available as Part No.435548,25/Pkg. SCISSOR STYLE-PART NO.435546 AND 455547 /BRACKET 1. LINKAGE , FUSIBLE V FIGURE 24 PULLEY ELBOWS There are two types of pulley elbows used to change the direction of the wire rope by 90°.ANSUL recommends for temperatures not in excess of 700 °F (371 °C). Part No.415670 has socket ends with set screws for 1/2 in.conduit, and Part No.423250 has com- pression ring ends also for 1/2 in.conduit.Pulley elbows must be ordered in quantities of 50 as Shipping Assembly Part No.415671 (socket end type)and Part No.423251 (compression end type). PART NO.415670 PART NO.423250 ® 0--2 P I 1 � — e� ..f wawa 000161 FIGURE 25 SECT@ON[[i-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-9 7-1-09 REV5 REMOTE MANUAL PULL STATION MECHANICAL GAS VALVES The remote manual pull station (Part No. 434618 or 435960) is The mechanical gas valves are designed to shut off the flow of gas made out of a molded red composite material. The red color to the appliances upon actuation of the regulated release assem- makes the pull station more readily identifiable as the manual bly.The valves are available in sizes of 3/4 in., 1 in.,1 1/4 in.,1 1/2 means for fire suppression system operation.The pull station is in.,and 2 in.ANSUL style;and 2 1/2 in.and 3 in.ASCO style.The compatible with the ANSUL Flexible Conduit.The molded manual valves are rated for natural and LP gas.Both styles are UL Listed pull station should be mounted at a point of egress and positioned "and includes the air cylinder,tubing, and fittings, Part No.15733, at a height determined by the authority having jurisdiction.Trim - for connection to the release mechanism. Rings, Part No.427074(pack of 10),are available. Maximum Part No.434613(Without Wire Rope) Part Operating Pact No.435960(With 50 ft(15.2 m)of Wise Rope) No. Description Pressure 55598 3/4 in.Gas Valve(ANSUL) 10 psi (0.69 bar) 55601 1 in.Gas Valve(ANSUL) 10 psi(0.69 bar) ue p� 55604 1 1/4 in.Gas Valve(ANSUL) 10 psi(0.69 bar) a iir 55607 1 1/2 in.Gas Valve(ANSUL) 10 psi (0.69 bar) I 55610 2 in.Gas Valve(ANSUL) 10 psi (0.69 bar) p()dd; 25937 2 1/2 in.Gas Valve(ASCO) 5 psi (0.35 bar) i 25938 3 in.Gas Valve(ASCO) 5 psi(0.35 bar) 1_ - r,. Row Capacity BTU/HR,at 1 in.P.D. (CFH) 0.64 SP GR FIGURE 27 Pipe Size P.D.1 in.WC 1000 BTU/ft3 E (inches) 0.64 SP GR Natural Gas FLEXIBLE CONDUIT 3/4 751 751,000 Flexible conduit allows for quicker installations and the conve- 1 1288 1,288,000 nience of being able to route the cable over, under and around 1 1/4 1718 1,718,000 obstacles. Flexible conduit can be used as a substitute for sten- - 1 1/2 2630 2,630,000 dard EMT conduit or can be used with EMT conduit.Flexible con- 2 4616 4,616,000 duit can be used only with the Molded Manual Pull Station, Part 2 1/2 5700 5,800,000 No.434618, and mechanical gas valve installations.The Flexible 3 7100 7,300,000 Conduit comes in a 500 ft (152.4 m) length, Part No.434525, or To calculate gas flow for other than 1 inch p.d.: together with 500 ft(152.4 m)of wire rope, Part No.435959. Also available is a Flexible Conduit Strain Relief (50-pack), Part New cfh=(of h at 1 inch)x,/new p.d. No.435979. - To calculate gas flow for other than 0.64 SP GR: A 50-pack of Flexible Conduit Inserts, Part No. 434347, is also New cfh=(cfh at 0.64)x✓0.64 available. 0. New SP GR .Note:Flexible conduit cannot be used in detection systems. A B C Valve Size in. (mm) in. (mm) in. (mm) 3/4 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) 1 in. 33/4 (95.3) -63/8 (161.9) 51/2 (139.7) 1 1/4 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) 1 1/2 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) 2 in. 5 7/8 (149.2) 7 7/8 (200.0) 6 11/16 (169.9) 21/2 in. 713/16 (198.4) 9 1/16 (230.2) 3 in. 7 25/32 (197.6) 9 1/16 (230.2) ni bAbsC A Pr IF s 1_ - Al 1i -4 B I I 314 IN.THRU 2 IN. 21/2 IN.THRU 3IN. 00=203 004203 FIGURE 23 SECTION Ill-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-10 REV 4 7-1-09 ELECTRICAL GAS VALVES MANUAL RESET RELAY The electrical gas valves are designed to shut off the flow of either The Manual Reset Relay, Part No.426151,is required when using natural or LP gas to the appliances upon actuation of the regulat- an electrical gas valve shut-off system.After the electric gas valve ed release assembly.The valves are available in sizes of 3/4 in., has closed, either due to system actuation or power failure, the 1 in., 1 1/4 in., 1 1/2 in., 2 in.,2 1/2 in., and 3 in.The valve is held valve cannot he re-opened, allowing gas to flow, until the reset open by an energized solenoid and upon system actuation, the relay button is manually pressed, re-energizing the circuit. The switch contacts in the regulated release assembly open,thus de- reset relay is available 120 VAC.The manual reset relay is also energizing the circuit to the gas valve solenoid,causing the valve recommended for electrical shut down. to close.Valves are available in 120 VAC and are UL Listed. '--„,\ Part Max Operating No. Description Pressure 13707 3/4 in.Solenoid Gas Valve (ASCO) 25 psi (1.7 bar) 13708 1 in.Solenoid Gas Valve(ASCO) 25 psi 0.7 bar) R3 550360 1 1/4 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 13709 1 1/2 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 13710 2 in.Solenoid Gas Valve (ASCO) 25 psi(1.7 bar) a 550363 2 1/2 in.Solenoid Gas Valve(ASCO) 5 psi (0.35 bar) 17643 3 in.Solenoid Gas Valve(ASCO) 5 psi (0.35 bar) > Flow Capacity BTU/HR,at 1 in.P.D. - FIGURE 30 (CFH) 0.64 SP GR 003007 Pipe Size P.D.1 in.WC 1000 BTU/ft3 (inches) 0.64 SP GR Natural Gas ELECTRICAL SWITCHES 3/4 264.96 247,500 The electrical switches are intended for use with electric gas 1 1091.01 1,119,000 valves, alarms, contactors, lights, contractor supplied electric 1 1/4 1662.49 1,730,000 power shut-off devices and other electrical devices that are 1 1/2 1818.35 1,900,000 designed to shut off or turn on when the system is actuated. 2 3117.18 3,251,000 . Switches are available in kits: One Switch Kit, Part No.423878, 21/2 6078.49 5,821,000 Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. 3 7169.51 7,430,000 423880,and Four Switch Kit,Part No.423881.Mounting hardware and 12 in. (305 mm) long wire leads are provided with each kit. To calculate gas flow for other than 1 inch p.d.: Each switch has a set of single-pole, double-throw contacts rated New cfh=(cfh at 1 inch)x✓new p.d. at: To calculate gas flow for other than 0.64 SP GR: IJIJcUL/CSA Rating ENEC Rating New cfh=(cfh at 0.64)x 0.64 250 VAC,21A Resistive IE4T105N Approved New SP GR 250 VAC,2 HP 250V,21A Resistive 125 VAC, 1 HP 8A Motor Load Valve A B Size in. (mm) in. (mm) COMMON --s- / N.O. 3/4 in. 3 5/16 (81.0) 3 5/8 (92.1) 1 in. 5 (127.0) 6 27/32 (173.8) 1 1/4 in. 7 13/16 (198.4) 7 29/32 (200.8) 0 0 r'''''" \ 11/2 in. 5 (127.0) 519/32 042.1) N.c. 2 in. 6 3/32 (78.6) 5 15/16 (150.8) 21/2 in. 713/16 (198.4) 729/32 (200.8) o 3 in. 7 13/16 (198.4) 7 29/32 (200.8) FIGURE 31 001612 B I -..i. I A FIGURE 29 003210 SECTION Si—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-11 7-1-09 REV.1 ALARM IMITATING SWITCH ML STYLE Fusible Link To Be Used The Alarm Initiating Switch Kit, Part No. 428311, can be field Fusible Shipping Where mounted within the ANSUL AUTOMAN release.This switch must Link Assembly Temperature Temperature be used to close a supervised alarm circuit to the building main fire Part No. Part No. Rating Does Not Exceed I'I alarm panel when the ANSUL AUTOMAN release actuates.This 550368(1) 551522(10) 165`F (74°C) 100°F (38 °C) I, action will signal the fire alarm panel that there was a system actu- 550365(1) 551523(10) 212°F(i 00°C) 150°F (66°C) ation in the kitchen area.The switch kit contains all necessary 550366(1) 551524(10) 280°F(138°C) 225°F(107°C) mounting components along with a mounting instruction sheet. 550009(1) 551525 (10) 360`F(182°C) 290°F(143 °C) The switch is rated 50 mA,28 MDC. 550367(1) 551526(10) 450°F(232°C) 360 °F(182°C) SPACER 56816 WHEN SPACER AND 56816(1) O 1 551527 73867(10) 500 °F 500 F(260 260°C) 400°F(204 CC 204°C) TOWARO ANSUL (25) ) AUTOMANSWITCH ARE PROPERLY MOUNTED,THIS DIVIDER MUST BE BETWEEN THE �y _ /N.O.AND N.C.TEP,I✓�INALS ® DI,�d) G// \ COM e A 11 0, \\ iy /N.O. o-ti y TEMPERATURE \ �\ x-y��/y �/ °Iw RATING STAMPED ON \ - v1.1 i® FUSIBLE LINK BODY a7_........ . - c (s �� ��� - - _ \ K STYLE ML STYLE 000170 000171 FIGURE 34 ALARM INITIATING !, SWITCH FIGURE 32 MAXIMUM REGISTERING THERMOMETER 004900 .The Maximum Registering Thermometer, Part No.15240,may be used to indicate the highest normal temperature for the protected REGULATOR TEST KIT area.Once this is established,the correct rated fusible link can be !, The Test Kit Assembly(Shipping Part No.56972)is required to test 'chosen. Other methods for determining maximum temperatures the regulator setting and nitrogen flow during 12-year maintenance .may be used. examinations. This will ensure that the regulator is functioning properly. HOSE/GROMMET PACKAGE The Hose/Grommet Package,Part No.418511,consists of a 24 in. isili1 � rubber hose and 2(two)grommets.This package is required when .expellant gas hose is routed outside the ANSUL AUTOMAN 11.00. I Regulated Release, Regulated Actuator, and/or tank enclosure -assemblies. - 130 011 e FIGURE 33 0001 s FUSIBLE (LINK Select correct UL Listed fusible link(s)for installation in detector(s) according to the temperature condition chart below: K STYLE Fusible Link To Be Used Fusible Shipping Where Link Assembly Temperature Temperature Part No. Part No. Rating Does Not Exceed 415739(1) 415739(1) 165`F (74°C) 100°F (38°C) 4 - 2°F(100 °C) 150 F (6G°C) 415741 (1) 415744(25) 280°F(138°C) 225°F(107°C) 415742(1) 415745(25) 360°F(182`C) 290°F(143°C) 415743 (1) 415746 (25) 450°F(232°C) 360°F(182`C)