HomeMy WebLinkAboutA17-0006_FA000 plans approved.pdf tattli OF /4- 40 Ltk r 109.R 1414 MORAINE LEGE\ 3 : �= ��1�,,r• �- Vail Fire&Emergency Services Ademco Vista 128 FAGP .© Vk �; cm: oziov,� Standby SYMBOL DEVICE MANUFACTURER/PART# MOUNTING . . 352331 Number of Current Total Current FACP Honeywell Vista-128BPT '; t ,. ?t` % ;� Device Type Devices (Amps) (Amps) Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox •. ;: ;% Approved as noted . . . . Q�..- Main FACP CPU 1 X 0.032 = 0.032 � �,sr......-- • 41935N Serial Interface 3 X 0.00015 = 0.00045 pp KP COSMOD4W Module 3 X 0.052 ' = 0.156 LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox i3 Smoke Detector 5 ' X 0.0005 . = 0.0025 i4 Smoke/CO Detector 7 X 0.0005 = 0.0035 Combination Smoke & 6160 Keypad 1 X 0.04 = 0.04 0 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box SUM COLUMN FOR STANDBY LOAD 0.23445 = AMPS Combination Smoke and Alarm Load ©co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box Number of Current Total Current Device Type Devices (Amps) (Amps) ® System Sensor 5601 P Main FACP CPU 1 X 0.032 = 0.032 Heat Detector w/4193SN Addressable module 4" square box 4193SN Serial Interface 3 X ' 0.00015 . = 0.00045 COSMOD4W Module 3 X 0.075 . = 0.225 c Cosmo Interface Module COSMOD4W i3 Smoke Detector 5 X 0.035 = 0.175 i4 Smoke/CO Detector 7 X 0.04 = 0.28 6160 Keypad 1 X 0.1 = 0.1 KB Knox Box Outside Horn/Strobe 1 X 0.195 = 0.195 SUM COLUMN FOR ALARM LOAD 1.00745 = AMPS Standby Load Required Standby Time in Hours ,0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox Current (Amps) Zo 0.23445 X 24 = 5.63 Alarm Load Required Alarm Time in Hours E Current (Amps) (15 MINUTES) GENERAL NOTES: 0 1.00745 X 0.25 = 0.25 a Add Standby and Alarm Load for Required Z 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN o Ampere Hour Battery 5.88 Cl) Multiply by the Derating Factor of 1.2 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE w Total Ampere Hours Required = 7.05 DEPARTMENT REQUIREMENTS AND NFPA 72. Batteries Provided: 12AHMinimum 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, w PROGRAMMING AND DEVICE OPERATION. Q 0 ZONE LIST ZONE # DESCRIPTION ci 1 SPRINKLER WATERFLOW z 2 SPRINKLER TAMPER 3 MAIN LEVEL CO DETECTION 4 MAIN LEVEL SMOKE DETECTION 5 UPPER LEVEL CO DETECTION 6 UPPER LEVEL SMOKE DETECTION 7 GUEST QUARTERS CO DETECTION CI:1Z) 8 GUEST QUARTERS SMOKE DETECTION 9 GARAGE HEAT DETECTOR 10 SYSTEM TROUBLE S E Q U E\C E OF Q k� 0 OPEATIO\S: Q z z z z o fralb) uJ 00 oo cnO z co cn i > iLL, o �� co cn N (nom > � J � Q (Doc w � mcn z w _ = O C� O O O O a_ � Z S- Z c z co (n w o 21- < E N E I- a a D m LI E0, H1- H1- H � U O0 DEVICE Q QD UDO � o � o Qo Q � DESCRIPTION >- >- o z - z - z - > z > zz I- ~ go go go ~ D ~ a QI� � � � � � < Qo SMOKE DETECTOR X X X HEAT DETECTOR X X X CO CARBON MONOXIDE DETECTOR X X X CSO SPRINKLER WATERFLOW SWITCH X X X X N- C9 CV SPRINKLER TAMPER SWITCH X X 0) O POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X N- 0)0) U) Z PROJECT \ FOVAT O \ : • I- w 1414 VVOA \ E DIVE v VAIL COLOA3O z w F � E ALAS V SYSTEV Z D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) Q X = 2-WIRE DATA, 2-#16AWG EOL EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES _ APPLICABLE CODES: 2015 IBC, 2015 IFC, 2013 NFPA 72 0 (/) N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG U FULLY SPRINKLERED = Z = 2-WIRE DATA CIRCUIT, 2-#16AWG D D D Z Q KP = KEYPAD CIRCUITING, 4-#18AWG2 FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW W 0 O RISER NOTES: ©co �co �co ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE CJS DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE - > LJJ 1. REFER TO VISTA INSTALLATION MANUAL FOR D D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE 0 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS I L,N0 Z 0 MORE INFORMATION. PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. HEAT DETECTORS L,N L,N MANUFACTURERS SPECIFICATIONS. C�I �� [1 WILL BE INSTALLED IN THE GARAGE. SOUNDERS ARE INTEGRAL TO w Q CL >-- 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (NP) MP) MP) DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE OUTSIDE OF THE = ct 0 D CO PRIOR TO INSTALLATION. WIRING DIAGRAM IS Z O HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE FIRE ALARM < 0 INCLUDED SUBMITTAL BOOKS. SYSTEM. O Q W 0120VAC DEDICATED POWER VISTA 128FPB Z CONTROL PANEL Z FLOW SWITCH U I- 0 Z TAMPER SWITCH ' J Z C!) TELEPHONE LINE -TELEPHONE LINE - SIECURITY -WP d- Q BELL N FIRE PROTECTION ENGINEER: 0 OUTPUT ,O, EOLR I DEBORAH SHANER, P.E., SHANER LIFE SAFETY PO BOX 1073, PRISCO, CO 80443 SHEET DESCRIPTION: ISE AG A V DAOUTPOT KP (KEYPAD I iKEYPAD PHONE: 970-409-9082 FIRE ALARM PLAN FAX: 970-797- 1898 DRAWN BY: DATE: DLS 1/29/17 SHEET#: FA-0.00