HomeMy WebLinkAboutB16-0500 plans approved SYMBOL LEGEND SECTION NO. \\ own of Vail 13 BUILDING GRIDLINE0 in ` <Jo®� �� -SECTION CUT d TIMBER FALLS CONDO '.OMPLIAN E ® T.O.PWD. Iv v� SHEET NO. / SPOT ELEVATION ELEV.100'-0" REMODELDa$ -- 172 Longview Ave P.O.Box 5874 SITE ELEV.=116'-0" (970)306 2175 DETAIL NO.� y Keegan wink�gmaiLcam DETAIL CUT a I DRAWING REVISION 4524 Meadow Dr Unit#906 1 _ SHEET NO.11/ 41110A Vail, CO 81657erode74_1-Town of Vail -� Eagle County LL z-'t ARCHITECTURAL DRAWINGS Q a III INTERIOR ELEVATION •A9.1 PERMIT SET `+ 1. A1.0 COVER SHEET DETAIL CUT 2. A3.1 MAIN LEVEL FLOOR 0 ® SIM. / EXTERIOR ELEVATION WINDOW MARK Issue Date: 11-8-16 3. A3.2 UPPER LEVEL FLOOR C A> PLAN UJ A4.1 •r 6. A4.3 LOFT ELEVATIONS 4. A4.1 KITCHEN ELEVATIONS n/ LIVING EXISTING BUILDING INFORMATION/AREA CALCULATIONS 5. A4.2 FIREPLACE ELEVATION LL 0) ROOM NUMBER DOOR MARK 7. M.4 INTERIOR PERSPECTIVE 0 100 DATUM:MAIN LEVEL FINISHED FLOOR=0'-0" 8. A4.5 INTERIOR PERSPECTIVE C ti >, MATERIAL LEGEND 9. A4.6 INTERIOR PERSPECTIVE -,, DLo C SECTION PLAN TYPE PLAN TYPE PLAN 10. A4.7 INTERIOR PERSPECTIVE t✓ = m 11. A10.0 ELECTRICAL 0 O CONCRETE m ° n RIGID INSULATION SCHEDULE AND NOTES 3 O 0 STEEL I I 12. A10.1 MAIN LEVEL RCP 0 O 0 0 PROJECT/CODE INFORMATION CONCRETE " �_♦►"�y / PARTICLE BD.OR MASONRY •••••••• WOOD FIBER BD. CODE: 2015 IBC,2015(ECC,2015 IMC STRUCTURAL ( ) (II - (0 ♦ ♦ , � ALUMINUM OR OCCUPANCY TYPE:R2 MULTI FAMILY CONDO 13.S2.2 2ND FLOOR -I O ; town Vali DESIGN 71 �./ pi t1-f rr'n r' a . �, Date:__ / Z - /7172 Longview Ave P.O. Box 5874 - (2)COPPER PLUMBING kgeega70)n wink75 – @gmail.wm I LINES TO BE RELOCATED 3 1/2" TO PANTRY BACK WALL 11_ (2900e. A-_—____ —I `-- > 1. , 0 WASHER DRYER TO BE Lu Q >-w - RELOCATED TO ENTRY 2X4 FURRING OVER tY O Ct Z v___ STROAGE CLOSET EXISTING CMU STRUCTURE O LL --L-, -g , U Q Q M— WALL TO BE REMOVE ; C -► -a Ur io G I I 1-1--- 1/4-M I TV ABOVE FIREPLACE PROVIDE NICHE IN wN I STONE VENEER FOR TV BRACKET .\ L.1_ O i0 O7 _ I 2 1 DW �_ A4.3GO 1 ORTAL 110 FIREPLACE PROVIDE '/ O 4 i-- �A4.1 LINE OF LOFT REQUIREMENTS PROVIDE VENTCLEARANCES PER E E Ln >^` --� AA� — — ABOVE i 0 � Vy Vu. I AS SHOWN IN ELEVATION 1/A4.2 CO C �1.1201N ° [ Z = ELECTRIC SLIDE IN r A�7n�` I \ NORTH O O �I 0 I F-I LINE OF SOFFIT ABOVE Q U RANGE Ki2�eyi ^ ��Pn ' '-, KITCHEN 1'-11 1/2" . �C.) 0 0 a J 1128 I — t 7 NEW WOOD FLOOR v/ 0 '� co EXTEND KNEE WALL BELOW I -425 SF SHOWN J 2 > W 2'-5 1/2" J — TRASH/ '• iv\ Q N • -_L J LRECYCLEti_i - , FLOOR PLAN GENERAL NOTE: BE REMOVED I vV' LLS TO i L.L_ 1. AEXSTRUU 1 APPROXIMATELL DIMNSIONS AND NEEDFROMETO BEISTING VERIFIEDCTINRE THEARE FIELD. in 2. ALL DOOR AND WINDOW TRIM TO BE REMOVED AND ENTRY L m REPLACED PER OWNERS SPEC G 1291 WALL TO BE REMOVE-MOVE BASE 1'-10" :OARD HEATER AND PLUMBING O = } _ O e n I; _ - J w Z J 1 WOOD FRAMED WALLS,FLOORS,AND,ROOFS PERMIT SET AND COLUMNS SHOWN WHITE WITH SOLID No. Description Date CLOSET LINEN P EXISTING ELECTRICAL PANEL ' ► _ ., --= BLACK LINES 1131 _132 BATT{ , L j EXISTING WALL, ROOF OR FLOOR SHOWN _ V •s/ . ��, /133 r 11'-2 3/4" WITH GRAY LINES DEMOLISHED WALL, ROOF OR FLOOR 30"BASE CABINET/ - WASHER/ _ _- _ - BEDROOM ] SHOWN WITH DASHED LINES COUNTER TOP DRYER —_1 135 CONCRETE WALL SHOWN WITH HATCH SKI RACKS AND SHELVING • -- _ NWALL, FLOOR, AND ROOF LEGEND a -DESIGN BY OWNER ---V- 1/4" - 1'-0" STORAGE/ ____ __ LAUNDRY ROOM N - M SHOWER ROOM--' 130 i'. = t - 134 6'-10" / 4'-11/4" 0 0' 4' 8' 16' 32' ‘IT.' t\ --__ _6___J Date 11-8-16 Of C04,..„ 04 Drawn by BKW O Checked by :KW KW STORAGE ACCESS UNDER STAIR � 9 Scale va^=r-o DRY VENT OUT SIDE WALL 7-4C----- '" • / MAIN 19'-1 1/4° / NJA K. 0 LEVEL t EEWI DEER * FLOOR 00404075 1. PLAN . F. 1 MAIN LEVEL FLOOR PLAN °1;s% ARG`�\�� I FLOOR PLAN GENERAL NOTE: �W C)ESIGN 1. ALL DIMENSIONS FROM EXISTING STRUCTURE ARE • APPROXIMATE AND EED TO BE VERIFIED IN THE FIELD. FLOOR/CEILING AREA SHOWN W/DIAGONAL 2. ALL DOOR AND WIN OW TRIM TO BE REMOVED AND / HATCH TO BE REINFORCE PER REPLACED PER OW ERS SPEC 172 Longview Ave P .Box 5874 STRUCTURAL ENGINEER STAMPED LETTER (970)3062175 WOOD FRAME WALLS,FLOORS,AND, ROOFS eega"wlnk@9maa.00m AND COLUMN SHOWN WHITE WITH SOLID _ BLACK LINES pI EXISTING WAL ,ROOF OR FLOOR SHOWN J WITH GRAY LI -- -_ - W 1/. 6'-3" DEMOLISHED WALL,ROOF OR FLOOR 0 /� - C 1 SHOWN WITH DASHED LINES O 1/2" EXISTIN TIC CONCRETE WALL SHOWN WITH HATCH C ACCESS OOR fr LL] F' ''' ., .-t .. rf WALL, FLOOR, AND ROOF LEGEND Eto 1/4" = 1'-0" o, 1 CEILING HEIGHT / 0 @ WALL 4'-8" 1 SEE:1/A4.3 OPEN TO BELOW / 70 C LO 0 5'-11" I l \ a .. L j S 6 O NEW SOFFIT UP TO CEILING BEDROOM 1� -NEW SOLID HALF ) 0 0 WALL W/WOOD TOP / Z ( / U U 136 @ 50"AFF5 CO ((T5 _ . KIDS PLAY AREA 1 I2'-5 1/2" (6 w 139 0 / —...1 2 NI ; ,. N 9' 6" LLin a LI Ct W WALL TO BE REMOVED C 1 LINE OF RIDGE BEAM ABOVE -e -C I r ( t PERMIT SET ADD VERTICAL PICKET TO \ ► MEM I in No. Description Date GUARD RAIL TO BE 4'-0"O.C. I I PermitResubmittal 1-11- 17 MAX ___ `NOTE HANDRAIL AND I GUARDRAIL TO BE 34"MIN.TO ) j I 38"MAX. HEIGHT ABOVE NOSING OR FINISHED FLOORIII , 1 -- --"- - I BATHROOM BEDROOM 137 0 1138 io Date 11-8-16 Drawn by BKW f Or�� , Checked by BKW A.. .�.x_,...,,. .. ;.:I ���V 0 �,�' 9Scale 1,4'=1,0- - *CO C NORTH. UPPER LEVEL { - 4'1- 00404075 U / PLAN O UPPER LEVEL FLOOR PLAN - - t�,s 1241/4 = 1 -0 A3.2 0' 2' 4' 8' 16' i FILLER 771.\--- ‘ A L I I \c\ - - - J — MOVE EXISTING 4"PLUMBING VENT TO BE = KW EXISTING 4"CASTIRON VENT CONCEALED ABOVE NEW PANTRY CABINETTi E S I G N STACK IN DROPPED CEILING TO — — - - _,..c, — BE MOVED TO BACK WALL t C) / ROLL-OUT SHELVES .I — — - n i ' PENDANTS 172 Longview Ave P. 74 WALL TO BE REMOVED (9 O. 06 175 RE:RCPS .)wn of Vail twoasos2ns N3 3/4" / �' keegan.vdnk(�gmail.wm /i r, — E / OPEN LIVING WALL AND CEILING TO ':VIEWED FOR C C . __ — ROOM BEYOND �n / BE REMOVED / MP IANCE J v \ p �V • EXTEND WALL / __ \— — — ---,� - = WOOD SIDE PANEL / .. / ?� lW /I0 / / NOTCH COUNTER AROUND WALL - Ii/ t, /'O - ,,r SLAB BACKSPLASH / Zo K — oN V SLAB COUNTER TOP-TYP. FIXED PANEL �, L.J.. 8O O BUILT-INS =/ L _ /\ C \ 1 I / , +. MICROWAVE / / N \ I ti -DRAWER� i DISHWASHER / \C — TRASH/ �in. — WOOD SIDE PANEL Q Cep C \-- - — / \ / / RECYCLING \ O Q 00 O N i U \ / / ROLL-OUT DRAWERS TYP. \ 2� 0 —'j= I 0 0 vv _ I" I 1 I (n a, . 1 1/2"-, 1 1/2" Q C\1 7/8" FILLER 3'-0" 1'-0" 2'-0" 2'-9" 1'-6" 1'-3" KITCHEN NORTH ELEVATION // - / - / / 1/ - 1/2" = 1'-0" F E ROUTE HOOD VENT IN FLOOR 1 1/2" 2'-0" 1 1/2" 4'-3" 1//" 2'-0" 1//" 3'-0" 7AV ETUCTURE. TURN DOWN IN CABINET T7 m �� l TILIZE E)'ISTING WALL PENETRATION. 36"RANGE HOOD W/LESS THAN 399 CFM BLOWER ENCLOSE LABINET IN 5/8" --.� 012YWALL4�PROVIC8IBAKE DRAFT 16') 32' Hr 4\ CAMPER. v ___. i_ � -:t\___ L FILLER PERMITSET i II 1 No.. Description Date _L '-0" C 1 Permit 1-11- 1 i I I 11 / / \ DROPPED CEILING TO BE REMOVED Resubmittal 17 IIIo WALL TO BE REMOVED in I I COUNTER DEPTH CABINET BOX ABOVE FRIDGE / / - 10 1/2" 2'-6" 10 1/2" y UNDER CABINET LIGHTING o f io I I RE:RCPS FULL HEIGHT SOLID SURFACE BACK SPLASH-SLAB OR \ i -` - GLASS � - � SLAB COUNTER TOP-TYP. /� Date „ats \ Drawn by BKW \ I J " I 7 \ U• \ v O`O Checked by HB o 7-1- I_ — _\ / \ 36"COUNTER DEPTH FRIDGE 9 sale 1/2".1,0' M _ _ ts K. O - v \ imp \ \ / ELECTRIC 30" * C -1--1=_,,,=/_ C C C C SLIDE IN RANGE * W� R ELEVATIONS U �1 �� \ � 00404075 V OKITCHEN SOUTH ELEVATION, 1/2" 2' 6" 3'-o" 11/2" 3-o" 7/8" A4.1 2 1-12" = 1'-0" 4' / / // ,d B KW i4 -1-own of Vail DESIGN • / REVIEWED FOR CODE COMPLIANCE ../- - - I,7 172 Longview Ave P O Box 5674 Date, L� (970)306 2175 u keegan.wink@gmail.mm ii �' 0 / FIREPLACE GENERAL NOTES: 0 / 2 1.) INSTALL GAS LOG SET AND BURNER PER MANUFACTURERSLLI / SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE CD SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 0 2.) INSTALL CHIMNEY @ LIVING ROOM PER MANUFACTURERS 0 D c SPECIFICATION. CONTRACTOR TO HAVE A COPY OF THE z SPECIFICATIONS AND INSTALLATION REQUIREMENTS ON SITE °p O SO INSPECTOR CAN VERIFY PROPER INSTALLATION. 0 O U J2 > w 124SQ. REQUIFACTURE MANUFACTURE - Q � N REMENTS in eN 6'-111/8" 6'-53/8" -/ / / Ct 0' 2' 4' 8' 16' W 00 LED LIGHTING COVE TO - — \ C WASH STONE VENEER I - - RE: RCP — — _ CAN IGHTS IN SOFFITH .......-- — ---=--- I RE: 'SCP E `I _ — IPERMIT SET THIN STONE VENEER — -- I No. Description Date 1 ___Ar 1 ' \ _ - ' - I r> I— 55"TV I - (:.1 0 NICHE FOR TV BRACKET-PROVIDE u.,) H : POWER AND TV CONNECTIONS. N I I I - \ 14"D EP X 2"THICK FLOATING WOOD SHELVES VERIFY NICHE DIMENSIONS W/ --.L------1— -1 J OWNERS SPEC - =_-:- --I__-- \ I LINE OF EXISTING FIREPLACE OPENING _ 2 1/2"X 2 1/2"X 3/8"STEEL ANGLE —� } / / Dale 11-8-16 BORDE'AROUND FIREPLACE OPENING M I I M I I / / ,- 21"D EP BASE CABINET Drawn by BKN G tC CO I -. I I I / / - O l v O�O Checked�' HB ORTAL 110 FIREPLACE ► < < > �4 sale As indicated - M1._ ^—± -1---'—'-- --7. ---1-1 9 � 1 V A / fV � � � 1 LINE OF NEW ORTAL FIREBOX -. - --- I Q = N_— I - y =ENA , K. 0 * WI' - ER * ELEVATIONS \ i' 00404075 V 81/8" ; 3/8; FI. �4� (REPLACE ELEVATION 2'-73/8" 3'-75/8" -0° z'-0' 2'-0" 11/2" 41 0 1/2" = 1'-0" / / / / FSARG A4.2 B KW ,� DESIGN ' n cif Vail LT�'i E W E D FO R72 Longview Ave 0 P 0 Box 5874 (970)306 2175 keegan.wink@gmail.com Date. ( — 24 _.. W Code 0 0 - KIDS PLAY AREA BEYOND / W \ rn O 7a � � c L = 3/4"WOOD TOP OVER 1/2"FINSH TRIM r^ - co IN °D SET BACK 1/2"TO PROVIDE REVEAL V J J2 > w NEW HALF WALL GUARDRAIL @ LOFT J Q N Lo UPPER LEVEL Ct I_ FINISHED FLOOR W - -�, 8' - 95/8" CO 2 _ F— som PERMIT SET No. Description Date / \ I KITCHEN BEYOND Co o) I' Co __IL 0' 2' 4' 8' 16' Date 11-8-16 OF CO` Drawn by ecw = 044:44:‘ .Q` Checked by HB Scale 1/2'=1'-0" j 90 _ y =ENJA K. 0 _ MAIN LEVEL # �N� �R # LEVATIONS . 0' - 0" 00404075 U LOFT ELEVATION -S+ A �\�� e. F° R� A4.3 B KW z` ° ( ;(:).Co-- f k DESIGN , - N , „ — / — c)---l' I 172LeBoa 8 4a i976j 306 zns keegan...k@gma'corn �} I NW 0 0 2 W o o) 0 UI / J � � w 3 1 IL —lj Ct Ill — CO __ H PERMIT__.....mAirallinirradill . SET ,_ �� No. Description Date \la --Nri I ar't IK. , 411 WH1 d U II Date 11-8-16 Drawn by BKW OF C°40 O Checkedd by HB ? 'tf Scale * ELEVATION 04404075 A 3D View 1 , 406, Gtr AR A4.4 B KW r,,,,v Of Vail DESIGN i.:g‘V;.):j.,1.1,,' FWEDFOR CODE F�IANCE 172LongvewA�e PO.Box 5874 (970)306 2175 7 �.l -moi keegan.wink@9mail.com 77)1 2 L LI W o rn O * Z L- - ra p co 0 O0 m -0 _ o J 2 > w Q . 1- i l Fir ail PERMIT SETN— Y I/ e COIn 2 I ,�� — i No. Descript on Date h iiii il —1FR- Date 114-16 of C 04 :::::" O ,9 �Q. O I- \\*.................. =ENJAMK. 0# WI R it ELEVATIONS 00404075 V 1 3D View 3 �, �SFo ����'� A4.5 BKW c• siGN p of Vali (97172 Longview Ave j! w P.O.Box 5874 t y (970)306 2175 ill:: V 9E p/ED FOR( D§�� KeegangiiewAveilwm iPLIANCE:-.:4';aPteiV; _1 Code- 3 w wo O Z ,L- o -°aOUa, .. D, o — co MOO��� J cW in J LL W CO -_ - PERMIT SET _ No. Description Date Biwa - irm__. . in------ ------j —___________ I.1 .7": I i ii TN.-, ---' —tri Date 11-8-16 �F O`O� Drawn by BKW Checked by BKW F Scale ENJA K. 0 • # WINEER # ELEVATIONS 0. 4- 00404075 V 1 3D View 2s�D fiG�� • A4.6 13 KW EESIGN p}.fn of Vail E °IEWED FOR CODE COMPLIANCE S172 Longview Ave Df _ 7 / /7 (P9 o Ban 754 iye 0 (971))30621175 p ate�s 9�T - keegan.wink@gmail.com °,i' _... ode is uj W 0 0 2 w 10 — cn Z 1` r- : 0 co o / -c c� = co' _ _ _ a)c __ ___ _ — J E rte= III IAN -_ = -_= _ t ca 5_ F- - PERMIT SET __ = No. Description Date IIIP _,_ ( / l L---\ mum N i Ie ' Date 11-8-16 T )11) 1 04 Drawn BKW checkedd by BKW N' Scale a ENJAI�iN K. # WI CE ER yk ELEVATIONS 00404075 U 3D View 4ki ��`rFD PtG���� A4.7 • BKW DESIGN . SURFACE MOUNTED FIXTURE @ WALL O DUPLEX OUTLET --"-FANEXHAUST FAN 172 Longview Ave P.0 Box 5874 TRU-FIG DUPLEX OUTLETC �� (970)3062175 TF SWITCH (� keegan wink@gwo(Lcow USB DUPLEX OUTLET W/(2)USB PORTS WALL MOUNTED UP LIGHT FIXTURE SWITCHED OUTLET(ONE SIDE ONLY) 3 3-WAY SWITCH/4-WAY SWITCH `I WALL MOUNTED STEP LIGHT FIXTURE O' W 6 GROUND FAULT INTERRUPT OUTLET (-i 0 Y D DIMMER SWITCH(MAY BE SHOWN AS 3-WAY) GENERAL NOTES: 0 WATER PROOF GFI OUTLET SURFACE MOUNTED FLORESCENT il MOTORIZED SHADE W/BUILT-IN POCKET UJ Ozo 220 OUTLET 1. LOCATION OF OUTLETS AND OTHER ELECTRICAL o DEVICES IS DIAGRAMMATIC--ACTUAL PLACEMENT OF FLOOR MOUNTED DUPLEX O SURFACE MOUNTED ON CEILING ELEMENTS,WORK, MATERIALS AND EQUIPMENT SHALL 0 CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE '= TELEVISION/PROVIDE 2 RG-6 AND 2 CAT-V OF COLORADO,AND NATIONAL CODES AND 0 1 ORDINANCES. 2. OUTLETS TO BE LOCATED VERTICAL AND 16"ABOVE 0 0 " O LED LIGHTING UNDER CABINET LIGHTING FINISHED FLOOR ,AND SWITCHES 42"ABOVE FINISHED =,ro.,E: 2 CATV TELEPHONE 0 FLOOR, UNLESS OTHERWISE SPECIFIED. AT 0 O o N MONOPOINT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT D RECESSED DIRECTIONAL DOWN LIGHT THE ARCHITECT. '' C ; LI OR SLOPED CEILING SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD 3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE J c .:I- RECESSED 4-LIGHT MULTIPLE DETECTORS WILL BE CONNECTED TO THE ALARM '� SYSTEM < LO N DIRECTIONAL DOWN LIGHT 1 = 4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. LI_ J-Box JUNCTION BOX COORDINATE FIXTURE LOCATION WITH STRUCTURE �/ AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS W POSSIBLE OELECTRICAL LEGEND 5. COORDINATE SWITCHED OUTLETS LOCATIONS AT CO 1/4„ _ 11 VANITY WALLS AND FLOORS WITH FURNITURE PLANS 2 AND INTERIOR DOCUMENTS 6. PROVIDE CARBON MONOXIDE DETECTORS F— THROUGHOUT THE HOUSE PER R315. CARBON - MONOXIDE DETECTORS WILL BE CONNECTED TO THE IPERMITSET Lighting Fixture Schedule ALARM SYSTEM. No. Description Date 7. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH Type CENTERLINE AT 46”AFF EXCEPT AS NOTED. VERIFY Mark Type Manufacturer Model Type Comments Count LOCATION &HEIGHT WITH OWNER 8. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH A FLAT CEILING NORA LIGHT W/HALO TRIM PROVIDE SORAA LED LAMPS 12 OWNER SPECS. RECESSED CAN G COMPACT FLORESCENT PER OWNER 1 9. PROVIDE POWER AS REQUIRED PER MECHANICAL -HIGH EFFICACY CONTRACTOR AND SPEC. 10. COORDINATE OUTLET W/FURNITURE PLANS PER J-BOX J-BOX CEILING FAN 1 OWNER RATED K LED ROPE LIGHT-HIGH JESCO FLEX-UPHO LED LINEAR LIGHTING STRIP, 18 LED LAMPS 2 EFFICACY PER 1' L UNDER CABINET LED JESCO FLEX-UPHO LED LINEAR LIGHTING STRIP, 18 LED LAMPS 2 ROPE LIGHT-HIGH PER 1' EFFICACY P PENDANT LIGHT PER OWNER 3 Grand total:21 Date 11-8-16 Drawn by BKW LIGHTING EFFICACY CALCULATIONS: �/ OF CO(0 Checkedby BKW . Y q� Scale 1/4'=1,-0' PER SECTION R404.1 IN THE 2015 IECC A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS, �P t Q WITH THE EXCEPTION THAT LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO UTILIZE HIGH EFFICACY LAMPS. co =ENJA K. ELEC. a 21 TOTAL FIXTURES ARE PROPOSED WITH 421 BEING LOW VOLTAGE, PER THE EXCEPTION ABOVE 17 FIXTURES WILL BE USED IN THE CALCULATION. 2,351 LAMPS ARE +* j, WI ER * SCHEDULE PROPOSED IN PROJECT. 2,327 LAMPS ARE HIGH EFFICACY. ,44 00404075 V / NOTES 260/268=.97 l%,s�D ARG�`�� 97%OF THE LAMPS IN THE HOUSE ARE HIGH EFFICACY WHICH EXCEEDS THE REQUIREMENT OF 75% IN R404.1 IN THE 2015 IECC. Al 0.0 • ', , Y . Of Vail B KW DESIGN E IEWED FOP CODE • MPLIANCE FLOOR/CEILING AREA SHOWN W/DIAGONAL HATCH TO BE REINFORCE PER 1 z on9 ewn e �+, �', PO.Boz 5874 STRUCTURAL ENGINEER STAMPED LETTER1----] , k9a��w�k@smai=om 71 A rI. W A I 0 ei) ,i MICROWAVE O I -� ',1 lj 2 i GFI�'Ja 1 1 I JLED COVE LIGHT TO WASH FACE OFA4.1 1 DW�``' _ A4.3 A4.2 p I THIN STONE VENEERO DISP /A — Z .T Oo ° 0CHEN ��% O A A WOODFRAMED WALLS,FLOORS,ANDROOFS128 ; AND COLUMNS SHOWN WHITE WITH SOLID U O 0 4) BLACKLINES =a)', A (:, A I K— EXISTING WALL,ROOF OR FLOOR SHOWN 4) 03 uJ I �� A 1 WITHGRAYLINES2 CGFI— R — — ] DEMOLISHED WALLROOF OR FLOORLA railNA SHOWN WITH DASHED LINES\11,_- �_= WALLS TO BE REMOVEDCONCRETE WALL SHOWN WITH HATCH LINE OF DROPPED CEILING TO BE REMOVED ENTRY —� WALL, FLOOR, AND ROOF LEGEND w \ I' •J-sox 129 U 1/4" = 1'-0" m .. - - " — — — — .77 iiimummilml 1 CLOSET fr-LINEN PERMIT SET 1131 1321 BATH No. Description Date / i 1331 .01 BEDROOM -Q1 135 / I __ REMOVE EXISTING WALL _ 17I I MOUNTED LIGHT FIXTURE PROVIDE 220 OUTLET FOR DRYER I , STORAGE/ LAUNDRY ROOM I SHOWER ROOM 1301 - - 134 --.1— ———— -- Date 11-8-16 Drawn by BKW Of C OC Checked by BKW 99a Sae „<_,_o. T /' 0) ENJA K. 0 I MAIN * WINE ER it LEVEL I FSC 00404075 V RCP 1 MAIN LEVEL REFLECTED CEILING PLAN 'b MAC Al 0. 1 F 1/4" = 1'-0" ',Am of Vain 30ci EU1/ f - "? - 17 . ... ..vED FOR CO ,a..e. .ee.11.9 4 O MPLIANCE 1;d).. if IP r, one design r : 46603 C: engineering consulting / STRUCTURAL ENGINEERING 7ter 1, .0 CIVIL 01/11/201ii .3:44% 7 orb .44, . STRUCTURAL ENGINEERING DRAFTING&3D MODELING 1+ c .........'• ....,-= PO BOX 2121 CEEK RD t/302 HDR HDR ����siuNAL' EDWARDS333 RDCOLORADO 81632 IIII, W r 10 R' ----0I 00P 970 306 7638 2nd FLOOR FRAMING PLAN ONEDESIGNRESOURCE COM N - - LI VIII : IIIIII NEW CMU OPENING, • • N I II NpR1H I ' I , N RE: NOTES 1/4 = 1-0 > z z N / N OPEN TO PLAN NOTES: A. BELOW 1. NEW FLOOR JOISTS ARE (2)-2.0E 1 3/4" x 5 1/2" LVL AS MANUFACTURED BY TRUS JOIS NEW(2) 5 1/2" LVL SISTERED / 1 N [(1) EA. SIDE]TO EXSTG. (1) 2x10 MACMILLAN, SISTERED ON TO EXISTING 2x10 WITH (2)-ROWS OF 12d GUN NAILS $ AT 16 o.c..ATTACH WI(2)-12d / N GUN NAILS(0.131 x 3 1/4")AT 1'-0" (0.131"x3 1/4")AT 12"o.c.STAGGERED. \ o.c. STAGGERED W 1 / N 2. TYPICAL E ERIOR HEADER (HD' t - ' . •DERS 0'-0" TO 4'-0" SHALL BE (2)-2x8 W/ o N (1)-2x6 TRIMMER AND (1)-2x6 KING STUD MIN. UNLESS NOTED OTHERWISE. CONTACT m W o 1 N E.O.R. FOR LARGER OPENINGS. 1 1 1 1 t o ._ IR / iii V ( LI 3. TYPICAL INTERIOR HEADER(HDR) (VERIFY): HEADERS 0'-0"TO 4'-0" SHALL BE (2)-2x8 WI I i 1 1 - 0 Z REVISIONS ISSUE (1)-2x4 TRIMMER AND (1)-2x4 KING STUD MIN. UNLESS NOTED OTHERWISE. CONTACT HDR HDR HDR HDR E.O.R. FOR LARGER OPENINGS. 4. STRUCTURAL MASONRY: MASONRY WORK SHALL CONFORM TO ACI 530.1/ASCE 6-05/TMS 602-05 "SPECIFICATION FOR MASONRY STRUCTURES". COMPRESSIVE tiD 0 STRENGTH OF MASONRY ASSEMBLY USED FOR DESIGN IS: F'M = 2000 PSI. FACING BRICK cn LD UNEFFECTED EXISTING SHALL CONFORM TO ASTM C216-04A GRADE SW. o ~ FRAMING NOT SHOWN g u Z O0 a z lL J I 5. GROUT: GROUT USED IN MASONRY WALLS AND BLOCK CELLS SHALL BE COARSE GROUT, -O D En - > I AS DEFINED BY ASTM C476-02, WITH A MINIMUM CUBE STRENGTH = 2,000 PSI 9 Q 0 O oc LLOz CL w o 6. NEW OPENING IN CMU: FULLY GROUT VERTICAL CELLS AT JAMBS OF NEW OPENING. a m Q O D 2 L1J I— VERIFY EXISTING LINTEL UNIT SPANS NEW OPENING PLUS 4" EITHER SIDE. IF VERIFICATION IMPOSSIBLE PROVIDE DOUBLE ANGLE LINTEL TO 4'-0" WIDE OF st I I (2)-6x4x5/16" (LLV)WI 5/8" DIA. EXPAN. ANCH's (3" EMBED)AT EACH END AND MID-SPAN. GROUT ENDS IN PLACE. I t 7. RE: ARCHITECTURAL DRAWINGS OR EXISTING CONDITIONS FOR SIZE AND LOCATION OF a ROUGH OPENINGS IN WOOD STUD WALLS. JOB NO. 16017 SHEET NO. 8. RE: ARCHITECTURAL DRAWINGS FOR ROOF SLOPES AND BEARING PLATE HEIGHTS. S2 .2