Loading...
HomeMy WebLinkAboutA17-0008_Cut Sheet.pdf Honeywell 580000 CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER Vi • S 415 S UL The 580000 is a 3V battery powered wireless carbon The detector consists of an electrochemical carbon monoxide (CO)detector intended for use with Honeywell monoxide sensor assembly coupled with a wireless alarm systems that support 5800 Series wireless devices. transmitter. The transmitter can send alarm, trouble, It provides early warning when its electrochemical sensing end-of-life, tamper and low battery condition messages technology measures carbon monoxide levels in the air. to the alarm panel. The 580000 is specifically designed for system operation Since there are no holes to drill or wires to run, you can and is fully listed to UL 2075 as a system supervised preserve the beauty of the home or building while detector.* It contains a piezoelectric horn which generates protecting its occupants from harmful carbon monoxide the ANSI S3.41 temporal 4 pattern in an alarm condition. gas. The 580000 is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO)is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 580000 is designed to warn the end-user well before the CO reaches a fatal level. The detector's CO sensitivity is evaluated to UL 2034. CO Levels and Time to Alarm CO Concentration Min. Time to Alarm Max. Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite** 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes *For a complete list of products that support system operation of the 580000 to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co **Life of product 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Electrochemical Sensing Technology- Electrochemical Full Supervision - The 580000 is fully supervised to monitor detectors are the newest, most refined CO detectors available for low battery, case tamper and trouble conditions. and provide the most accurate measurement of CO Test/Hush Button-This dual purpose button allows the concentration obtainable. They can take readings from low end-user to perform periodic testing of the detector. In the levels that may be hazardous over long periods of time to event of a CO alarm, this button will silence the local sounder high concentrations that present an immediate danger. alarm for a five minute period. Note: the Hush feature will not Local Sounder-A built-in piezoelectric horn generates the operate at levels above 350 ppm (parts per million)carbon ANSI S3.41 temporal 4 pattern in an alarm condition. The monoxide (see figure 1). local sounder will also alert the end-user of other conditions Versatile Mounting - Whether you choose to affix the such as low battery, detector trouble and end-of-life. detector to the ceiling or a wall, mounting is made simple LED Status Indicators- Dual LEDs provide local visual with the enclosed hardware. The mounting base has large indication of the detector's status—including normal operation, mounting ports, which accommodate drywall anchors for alarm, low battery, trouble and end-of-life (see figure 1). easy surface mounting (see figure 2). End of Life Timer- When the detector has reached the end Tamper Protection and Tamper Resistant Element- of its life, the detector will send a trouble signal to the panel. The detector has a built-in tamper switch that can This indicates that the CO sensor inside the detector has communicate back to the control panel in the event it is passed the end of its life and the detector needs to be removed from the base. For an added level of security, replaced. The detector's lifespan is approximately six years the detector also includes a tamper resistant element that from the date of manufacture. prevents removal from the base without the use of a tool (see figure 2). MOUNTING SCREWS A (INSTALLED) El TEST BUTTON .,3° oolnal 1111111111111 V ` \ )D6')',0) >b -YO O4)bA �,°+ a°� NsnH 1s�1 ooyo� sa 10* 1 ddmB TAMPER 6 RELEASE TAB O z GREEN LED ^� EEST RED LED ESZ 0 Q J/ GQ ENGAGE NOTCH WITH TAMPER RELEASE TAB ON BASE AND TURN CLOCKWISE TO LOCK Figure 1 Figure 2 580000 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ)for CO detector requirements in your area. Some recommendations for installing the 580000 are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet / Ak ■ • For wall mount BEDROOM - The detector should be at least as high as a light switch and at least six inches from the ceiling TO BEDROOM BR BEDROOM • For ceiling mount ■ KITCHEN GARAGE - The detector should be at least 12 inches from CLOSED LIVING DOOR any wall ROOM MIN • CARBON MONOXIDE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE SPECIFICATIONS • Power Source: One 3V CR123A lithium battery(included) • Audible Signal (temporal 4 tone): 85 dB in alarm (at 10 ft.) • Height: 2.3" (58mm) • Diameter: 5.3" (135mm)with mounting base • Weight: 7 oz. (241 g)without battery • Operating Ambient Temperature Range: 32° F to 100° F(0° C to 37.8° C) • Operating Humidity Range: 15% to 95% relative humidity, non-condensing • Agency Listings: - Listed to UL standard 2075, *CO sensitivity is evaluated to UL 2034 - 580000A ULC Listed - tested to the CAN/CSA 6.19.01 standard ORDERING 580000 Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 580000A Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing *For a complete list of products that support system operation of the 580000 to UL standard 2075 and 580000A ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 L/58000D/D Melville, NY 11747 March 2009 March 2009 www.honeywell.com ©2009 Honeywell International Inc. i I I • 1 .. lait4 • 5800WAVE WIRELESS SIREN • Honeywell's 5800WAVE is a fully wireless siren that provides periodic status information and battery back up for an added level of performance and protection. The flexible design simplifies installation, saves time and installs in seconds at any location without the need to run wires. System status is shown on the 5800WAVE with three LED's directly on the front of the unit. FEATURES • Siren output level is 95 dB at three feet • AC powered with a rechargeable • Lowers labor costs and 12 hour battery backup saves time •Transmits module status, including mounting tamper, low battery and • Plugs in to any standard duplex • Simplifies installation AC loss to the control panel receptacle and installs in seconds • Compatible with LYNXR(Rev 10 • LED; show system status of the device • Provides temporal pulse sounding for or higher)and VISTA controls that fire alarms support the 5883 transceiver SPECIFICATIONS • Dimensions: 4.5" W x 7.5" H x 2.25" D • Frequency of Operation: 345 MHz • Current: 202mA Typical (114mm x 191 mm x 57mm) • Input Voltage: 120VAC • Operational Temperature • Output Level: 95 dB at three feet 32° F to 122° F(0°to 50°C) ORDERING mi IMMO' 5800WAVE Wireless Siren Honeywell Security&Communications Honeywell Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 U5800WAVE/D March 2008 www.honeywell.com ©2008 Honeywell International Inc. Honeywell 5808W3 < 0 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN ( 1 WIRELESS TRANSMITTER ir4r. _ Honeywell's 5808W3 is a 3V lithium powered, Since there are no holes to drill or wires to run, you can photoelectronic smoke/heat detector with a built-in preserve the beauty of the building while protecting it.The wireless transmitter. It is intended for use with any 5808W3 is an ideal smoke detector for those difficult to wire 5800 Series Wireless Receiver/Transceiver for residential locations, applications where room aesthetics are critical, or installations(for commercial installations,the 5881 ENHC where hazardous materials exist. or the 5883H receiver is required). All models also feature a restorable, built-in, fixed temperature The transmitter can send alarm, tamper, maintenance(when (135°F)thermal detector that is also capable of sensing a control panels are equipped to process maintenance signals), pre-freeze condition if the temperature is below 41°F. and battery condition messages to the system's receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke— virtually eliminating nuisance alarms. FEATURES • Improved Robust RF Field • Drift Compensation • Easy-to-install Mounting Base Strength Virtually eliminates nuisance alarms The sturdy mounting base allows the The distance between the detector from long-term dust build-up by detector to be more easily installed and receiver has been significantly automatically adjusting the detector's on uneven surfaces(i.e. stucco). The increased without the need for a sensitivity mounting base has larger mounting repeater • Removable Detector Cover and ports, which accommodate drywall • Smoothing Algorithms Chamber Top anchors for easy surface mounting. Mathematical calculations in the The technician is able to quickly and detector's software that minimize easily clean the detector chamber ADDITIONAL FEATURES: nuisance alarms by smoothing out without disassembling the detector . Utilizes one long life 3V lithium short term spikes from dust and head battery smoke • Approved UL Listings for Residential pp g Microcontroller runs on a 4.0 MHz • Smart Check and Commercial Applications clock A signal is sent to the control panel Both residential and commercial • Horn operates at 3.3 KHz with sound when the detector requires cleaning. installation requirements are met pressure level of 85 dBA at 10 feet This allows a regular, non emergency •Additional LED Status Indicators • Built-in wireless transmitter, temporal service call to clean the detector Identifying between alarm or trouble code 3 sounder before it goes into alarm. conditions is a snap with green and • Maintenance signal fully complies red LED status indicators.A green LED with the sensitivity test requirement denotes a normal condition while the specified in NFPA 72, 7-2.2 and is red LED indicates abnormal conditions. approved by UL 5808W3 PHOTOELECTRIC SMOKE/HEAT DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER SPECIFICATIONS • Dimensions •Air Velocity • Power Source -Diameter: 5.3"*, Height: 2.30" - 1,000 ft./min. max. -One 3V CR123A lithium Batteryt •Weight • Operating Voltage •Audible Output -8.5 ounces(without batteries) -2.5-3.6VDC -85 dB min. at 10 ft. • Operating Temperature • Standby Current • Fixed Temperature Heat Sensor -32-100° F(0-37.8°C) -8.5 mA avg. -135° F Fixed • Humidity Range •Alarm Current •Agency Listings -0%to 95% RH, non-condensing -35 mA max. -UL268-Commercial and Residential With adapter bracket(4.9"without mounting base) t Replacement batteries include Duracell DL123A,Sanyo CR123A,Panasonic CR123A,or ADEMCO 466 ACCESSORIES(sold separately) SENS-RDR Infrared ,, RT Removal Tool Sensitivity Reader . ... ........ .... Simplifies the attachment • . Reduce testing time with the . • and removal of the handheld SENS-RDR infrared detector head to the . `' `.,. sensitivity reader.The reader mounting base; it may _ _§ • _ simplifies sensitivity measurements be attached to a threaded . .- and displays them precisely in �. extension pole or broom ; , terms of percent per foot handle thereby eliminating obscuration. The SENS-RDR the need for ladders. eliminates the need for magnets, voltmeters and ladders. ORDERING 5808W3 Photoelectric Smoke/Heat Detector with Built-in Wireless Transmitter Accessories sold separately: SENS-RDR Hand-held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base Automation and Control Solutions Honeywell Honeywell Security&Communications Hone 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 L/5808W3DS/D September 2008 www.honeywell.com ©2008 Honeywell International Inc. 6160RF M DELUXE CUSTOM ALPHA INTEGRATED KEYPAD/RECEIVER - S 1 WITH DOOR ATTACHED The 6160RF's integrated keypad and receiver design helps reduce Dealers can add the 5828 and 5828V wireless keypads to VISTA installation, material and inventory costs while increasing valuable for the first time, presenting a tremendous upsell opportunity by add-on opportunities. It adds full wireless capability to any VISTA letting them offer their customers secondary wireless keypads on control without additional wiring or sacrificing zones and can help every installation with virtually no install time. close sales by easily adding 5804, 5804BDV or 5878 wireless interfaces for end-user remote convenience. FEATURES • 6160 Custom Alpha Keypad •The 5800TM Module needed to • Comfortable soft-touch keys labeled • Built in 5881 ENH unlimited zone support the 5804BD and 5804BDV with simple commands are illuminated wireless receiver is already built-in for nighttime visibility • Compatible with 5828/5828V wireless • Supports encrypted operation • Four larger function keys can be keypads on VISTA systems* of the 5804E and 5804BDV programmed for one touch operation • Single four-wire run is all that's required four-button keys and are accessible even when the door is closed • It is the ideal choice where wireless keys are to be used: Easy to Operate - Keys can be programmed at the panel, •The custom alpha display is easy Stylishly Designed just as they would with the 5881 ENH to read, with large characters and • Sleek,white design blends with any decor • Fully compatible with all 5800 wireless simplified descriptions • Contoured, removable door lets devices including bidirectional devices* •The sounder beeps to help identify customers customize the keypad for security system status the look they want *Not compatible with 5839 •With the door closed the keypad has a smooth, unobtrusive appearance SPECIFICATIONS Dimensions Wiring Current • 5 5/16" H x 7 3/8" W x 1 3/16" D • -(Black): Ground • Standby: 50ma (135mm x 190mm x 30mm) •+(Red): +12 VDC(Aux. Power) •Activated: 150ma Sounder • D1 (Green): "Data In"to control panel Compatibility • Piezoelectric • DO(Yellow): "Data out" from • Fully compatible with all VISTA controls control panel ORDERING: 6160RF Keypad/Receiver 5828 Wireless Fixed English Keypad 5828V Wireless Talking Fixed English Keypad Honeywell Security&Custom Electronics Honeywell Honeywell 2 Corporate Center Drive Suite 100 P.O. Box 9040 Melville, NY 11747 116160RF/D September 2007 www.honeywell.com ©2007 Honeywell International Inc. Honeywell VISTA-21 iP CONTROL PANEL t Honeywell's high capacity, feature-rich VISTA-21 iP lets you to and from the control panel. When used with an optional deliver more value to your customers on each and every AlarmNet GSM that snaps right on the board, the VISTA-21 iP sale.The VISTA-21 iP provides up to 48 zones of protection, can be installed in premises without TELCO lines-guaranteeing an on-board IP connection, graphic keypad support and communication independent of any infrastructure. The panel's dual partitions.The VISTA-21 iP gives you the ability to send installation advantages, innovative end-user benefits and alarm signals and upload/download via an Internet Protocol robust system capacity make the value-priced VISTA-21 iP (IP), improving the speed at which information can be delivered an ideal choice for higher-end installations. FEATURES • Internet alarm reporting and • 16 output devices • Dynamic Signaling uploading/downloading capability —Relays(Model 4204 Relay Modules, —Reduces redundant reporting to via on-board AlarmNet Internet or 4229 Expansion Module), and/or the central station when multiple Communicator X-10®devices(when used with a reporting methods are used; •Supports four graphic 4300 Transformer) i.e. digital dialer and AlarmNet radio touchscreen keypads • Four installer-configurable zone •Wireless keys can be programmed types allows the installer to create Valuable End-User Features without using zones custom zone types by assigning •Viewable on system keypads: • Eight on board hardwired zones all zone attributes —Exit countdown standard(15 when Zone Doubling •Supports four-wire, and up to —Time and date display* feature is used) 16 two-wire smokes —Event log* —40 hardwired expansion zones —Works with Sentrol CleanMeT"' •Auto keypad backlighting on entry -40 wireless expansion zones maintenance signal p • Keyswitch arming •Two low current on-board • Multiple actions on output devices • trigger outputs depending on system state Programmable macro buttons and —Turns lights off when system arms single button arming • 100 Event Log viewable at system •Supports varietyof wireless remote keypads with time/date stamp —Turns the same light on pp a when system disarms controls for single-button operation •48 system user codes assignable —Flashes same lights when system •User Scheduling to either partition is in alarm —Automatically activates X-10 and • Expandable to 48 total zones when • Built-in phone line cut monitor relays at programmed times used with hardwired and/or wireless with programmable delay and —Latchkey reports to pagers expansion modules annunciation options —Auto arm/disarm •Two independent partitions plus a —Display on system keypads —"User access"time windows common partition —Trigger local sounders •Supports up to four end-user —Global arming from any —Trigger system bell numeric pagers system keypad •VIP Module allows system control —Goto function to view or operate Security Dealer Features from any touchtone phone one partition from the other •Automatic System Load Shed • —Separate partition account numbers y Chime by zone —During extended AC power fail, the system battery will be disconnected to prevent irreversible `Requires custom alpha keypad battery failure. Reduces service calls to replace batteries. VISTA-21 iP CONTROL PANEL SPECIFICATIONS Electrical •5881 ENL RF Receiver supports —Standard for Safety for Digital Alarm •Aux. power 12VDC, 600mA maximum up to eight zones—60mA Communicator System Units— •Seven hour standby at 400mA aux. •5881 ENM supports up to ANSI/UL 1635, 1996(3rd edition) load with four amp hour battery 16 zones—50mA —Safety of Household Burglar Alarm •5881 ENH up to 48 zones—50mA System Units,ANSI/UL 1023, issued • 16.5VAC/40VA transformer 1996/11/25(6th edition)with revisions •Alarm output 12VDC, 2.0 amps max. •5883H High Security Transceiver up to 12/30/04 —For agency listed installations, Module supports up to 48 zones— g y80mA •Commercial Burglary: combined aux. and alarm output cannot exceed 700mA •Supports Eagle 1225 and 1221 boards —Standard for Safety for Police Station Connected Burglar Alarm Units and Output Control Keypads Systems—ANSI/UL 365(4th edition), •Supports up to four relay boards •6160 Custom Alpha issued 1997/01/31 with revisions up (up to 16 relays) (required for programming) to 2005/03/08 —100mA —Standard for Safety Local Burglar •Optional X-10 transformer/interface Alarm Units and Systems—UL 609 (part no.4300)may be used to control •6160V Custom Alpha Voice (11th edition), issued1996/0UL 8 with up to 16 X-10 receiving devices —100mA revisions up to 2005/03/17 Zones •6150 Fixed English LCD —Standard for Safety Central Station —85mA/40mA Burglar Alarm Units—ANSI/UL 1610 • Eight hardwired zones •6150V Fixed English Voice LCD (3rd edition), issued 1998/10/26 with (15 with zone doubling) —85mA/40mA •Selectable response 10msec, revisions up to 2005/08/16 350msec, 750msec •6150RF Fixed English RF LCD -85mA/40mA Communications •Assignable to any partition •6148 Fixed English LCD •VISTA-GSM Snap-in Dual-Path Digital •20 selectable zone types plus four —70mA/30mA Wireless Communicator(IP required configurable zone types •6270 Graphic Touchscreen for activation and registration) • Programmable swinger suppression User Interface •Touchtone or pulse standard TELCO •6271C Color Graphic Touchscreen dialers Expansion Devices User Interface • Formats supported •4219—Eight hardwired zones—16mA —ADEMCO Contact ID •6271 CV Color Graphic Touchscreen —ADEMCO 4+2 Express •4204—Up to four relays—15mA User Interface with Voice standby(each active relay —ADEMCO low speed draws an additional 40mA) •8132 Symphony Advanced User —Sescoa/Radionics Interface •3+ 1, 4+ 1 and 4+2 reporting •4229—Eight hardwired zones and two relays—36mA(each active relay Agency Listings • Reporting capabilities draws an additional 40mA) ETL listing —Split —Dual Accessories • Residential Fire and Burglary: —Split/Dual—True dial tone detection •VISTA-GSM Snap-in Dual-Path Digital —Household Fire Warning System • Low battery reports 11.2—11.6VDC Wireless Communicator(IP required Units—ANSI/UL 985, 2000/05/26 • for activation and registration) (5th edition)with revisions up to AC loss and restoral reporting supported •4286 VIP Voice Module—220mA 2004/04/29 ORDERING VISTA-21 iP Control Panel VISTA-21iPSIA Control Panel for SIA Installations VISTA-GSM Optional Snap-in Radio Module VISTA-ULKT Cabinet for Listed Commercial Burglary Applications Honeywell Security&Communications Honeywell Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 LNS21iPD/D August 2008 www.honeywell.com ©2008 Honeywell International Inc. ,T SYSTEM - �$ SENSOR° Mini-Horns = - The SpectrAlert®Advance series of mini-horn sounders are designed to simplify installations to provide - primary and secondary signaling for fire and security -- ______ _, applications. SPECTRIert A N C Features The MHR and MHW mini-horns operate at 12 and 24 volts and are 12 and 24V operation ideal for hotel,motel or residential fire system applications,where • a smaller notification device is desired.The mini-horns offer high •High and low volume settings and low volume settings,and temporal or non-temporal tones. The •Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically •Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. •Compatible with MDL sync module •Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert-sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings UL S Nc 4* MEA R"‘ approved APPROVED 54011 3028007 MEA7-07-E 7135-1653196 SpectrAlere Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini- horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuit""Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9"W x.45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/4"deep) Flush:Standard 4"x 4"back box Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White *--. SYSTEM m2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensoccom for ._)' SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0414-001.12/09•#2266