HomeMy WebLinkAboutB17-0037 Solar Calculations.pdf ACTIVE ENERGIES SOLAR.. SOLAR INSTALLATION INFORMATION Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-423 3/info@activeenergies.corn) Site: Crow Residence 2150 Ptarmigan Road Vail, CO 81657 System Layout: Single Panel=5.38ft tall X 3.26ft wide System Size= 16.4ft tall X 38ft wide(including mounting equipment) Panel Arrangement: 3 rows of 11 panels oriented in the portrait position,mounted flush on the south facing roof,separated around the vent and exhaust pipes 21S :i PtarmiganFDad ;" New HCE meter and PV Production Meter l6(: I. �f - - • -.. .1 i• 1 Jr Pc'111 I.4 . _ liiiii gi . r woo* • OOP Holy Cross electric meter now located on northwest side of the garage. PV production meter to be located next to new Holy Cross meter. Inverter to be located in the garage -Minimum Designed Temperature: -40°F -Maximum Ambient Design Temperature: 140°F -All AC wiring to be completed by project's Colorado licensed master electrician -All DC wiring to be overseen by NABCEP certified installer Page 1 of 4 3/6/2017 P.O.Box 7627,Avort,CO 81620 I P: 910.227.0272!303.330.4880 I F: 866.4033455 I www.activeenexgies.tam ACTIVE ENERGIES SOLAR,. CALCULATIONS 8.745kW System Size (STC) • 33 Canadian Solar CS6K-265M solar panels @ 265 watts • 33 integrated SolarEdge P300 Optimizers • 1 SolarEdge SE7600A-US inverter(2 strings of 16/17 modules/optimizers) • Fixed array tilt angle: 22.62° • Array azimuth: 120° (where 180° is south) • Estimated annual power production: 11,778kWh Maximum PV System Voltage: 690.7 Voc = 37.7V/module 37.7V x 1 module= 37.7V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.31/°C (-65C° x (-.0031C°)) = .2015% ((.2015% x 37.7V)x 1 panels) + 37.7V=45.1V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Is°/Imax= 15A 15A x 1.25 = 18.8A Maximum PV Output Circuit(Array) Current: 690.8 (A)(2) Max Input for SE7600A-US =23A Inverter Output Circuit Current: 690.8 (A)(3) 32A @ 240V Page 2 of 4 3/6/2017 P.O.Box 7627,Avort,CO 81620 I P: 910.227.0272!303330.4880 I F: 866.403.3455 I ur, v.activeenexgies.com ACTIVE ENERGIES SOLAR,. CONDUCTOR SIZING Pass Thru Box from Optimizers to Inverter (combined strings): 33 panels x 265w= 8,745w/350v=25A 25A x 1.25 = 31.2A #10 THWN-2 Table 310.16 40A No conduit fill adjustment Table 310.15 (B)(3)(a) No Temperature correction factor Table 310.15 (B)(2)(b) Inverter to Disconnect to Service Panel: Nameplate maximum continuous output current: 32A @ 240V 32A x 125% =40A 210.19 (A)(1) #8 THWN-2 Table 310.16 50A (75°C column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 40A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop Page 3 of 4 3/6/2017 P.O.Box 7627,Avort,CO 81620 I P: 910.227.0272!303330.4880 I F: 866.403.3455 I ur, v.activeenexgies.tam ACTIVE ENERGIES SOLAR.r Line Diagram Crow Residence 8.745 kW Utility Interactive Photovoltaic 1250 Ptarmigan Road System Vail, CO 81645 Modules: 33 Canadian Solar CS6P-265P-SD Voc= 37.7V Isc/Imax= 15A Array mounted on roof Optimizers: 33 integrated SolarEdge P300 4#10 PV Wire 33 Canadian Solar CS6P-265P-SD Solar Panels 1#6G Bare Cu 33 integrated SolarEdge P300 DC Optimizers 2 String X 16/7 Modules/Inverter Conductors in Free Air Inverter: SolarEdge SE7600A-US Operating Voltage: 350V Pass-Thru 1 2 3 ... 16 Operating Current: 15A Box Max System Voltage: 500V Located on , _tj tJ t tJ Max Output Current: 30A roof Placard on meter and main panel stating "Photovoltaic System Connected" o \ per Holy Cross specifications Tilt Angle: 22.62 17 18 19 33 Array Azimuth: 120° Net Meter on • Production: 11,778kWh/yr +/_60' IN ---- - northwestt Lti 2#10 HTWN 2/FMC M tJ tJ side of garage 1 #10 Ground Notes: -See Calculation Sheet for conductor +/-10' %"C EMT/PVC/FNMC/NM-B sizing. 3#8 THWN-2 -All conductors are copper unless 1 #8 Ground otherwise noted. • - Inverter listed (UL-1741)to de- Production • energize upon loss of utility voltage • Meter housing per NEC 690.61. • • with lever Backfeed bypass * Breaker: - Inverter has integral ground-fault adjacent to 40A protection per NEC 690.5 meter2P -240V 1 Phase Service Panel rating Inverter w/ 4 240V of 200A(bus rating 200 amp and 200 Integrated DC Disconnect •. " Main disconnect)to accommodate rTh SolarEdge SE7600A-US DC Grounding . 40A+200A=240A supply(up to NEMA 3R/Arc Fault/Rapid Shutdown Electrode Conductor • 120%of connected Max AC Output:32A @ 240V solid bare#6 Cu power sources Located in garage per NEC 250.66(C) . Service Panel from residential installations per NEC . . .• In garage 690.64(B)(2)) Page 4 of 4 _ 3/6/2017 P.O.Box 7627,Avon,CO 81620 P: 970.306.4233 F: 866.403.3485 1 www.activeenergies.com i • r r CanadianSolar CS6P-260 1265P-SD Optimized by solar- • • = Canadian Solar Smart DC module features an innovative integration of Canadian Solar's module technology and SolarEdge's power optimization for grid-tied PV application. By replacing the traditional junction-box with a +— _ SolarEdge power optimizer,the Smart DC module optimizes power output at module-level.With this S ' feature,the Smart DC module can eliminate the module-level mismatch and decrease shading ---- losses. Furthermore,the Smart DC module provides *Optional black backsheet module-level data to minimize operational costs available upon request and allow effective system management. KEY FEATURES 25 insurance-backed warranty years non-cancelable,immediate warranty insurance Harvest up to 25%more energy '' linear power output warranty 25% from each module • Maximizes power from each individual 10 product warranty on materials module against potential mismatch risk =, years I and workmanship • Decreases shading losses • Reduces cell series resistance MANAGEMENT SYSTEM CERTIFICATES* Easy installation,simple system design ISO 9001:2008/Quality management system • Integrated smart solution, no need to ISO/TS 16949:2009/The automotive industry quality management system add other accessories ISO 14001:2004/Standards for environmental management system • Enhances the shading tolerance OHSAS 18001:2007/International standards for occupational health&safety • Longer and uneven string using SolarEdge inverter cell-level stress PRODUCT CERTIFICATES* release technology IEC 61215/IEC 61730:VDE/CE UL 1703/IEC 61215 performance:CEC listed(US) Reduced BoS Costs UL 1703:CSA • Up to 11.25 kW—15 kW per string p sP ( E .' allows for more modules based on ove cc <;ceel different inverters *As there are different certification requirements in different markets,please contact your Canadian Solar sales representative for the specific certificates applicable to the products. Free module level monitoring system 0 • Full visibility of system performance • Free smart phone app for CANADIAN SOLAR INC.is committed to providing high quality the monitoring system solar products,solar system solutions and services to customers around the world.As a leading manufacturer of solar modules and MORE More Safety PV project developer with about 10 GW of premium quality • Automatic drop of DC current and modules deployed around the world since 2001,Canadian Solar voltage when inverter or grid power Inc.(NASDAQ:CSIQ)is one of the most bankable solar companies is shutdown worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph, Ontario Ni K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com MODULE/ENGINEERING DRAWING(mm) CS6P-265P/I-V CURVES A A Rear View Frame Cross Section 10 10 9 9 L ALUMINUM FM= 8 8 -11,\ 7 7 a-a a-e 11111 ,--11. i - ee air 6 6 I)i 4 ,I 4 . ,1 w,° ra°M3N2 1.1111111111111111111n \12 111 _111 ■III 0vo lil51015 20 25 30 35 405 10 15 20 25 30 35 40• 1000 W/m' 5°C • I llllll■l��Illlll� • 800 W/m' 25°C • • 600 W/m' 45°C • • 400 Wim' 65°C U ELECTRICAL DATA/STC* MODULE I MECHANICAL DATA Electrical Data CS6P Specification Data Power Optimizer connected to a Cell Type Poly-crystalline,6inch SolarEdge Inverter 260P-SD 265P-SD Cell Arrangement 60(6x 10) Nominal Max.Power(Pmax STC) 260 W 265 W Dimensions 1638x982x40 mm(64.5x38.7x1.57 in) Nominal Max.Power(Pmax NOCT) 189 W 192 W Weight 19.7 kg Open Circuit Voltage(Voc STC) 37.5 V 37.7 V Front Cover 3.2 mm tempered glass Output Voltage Range(Vout) 5-60 V 5-60 V Frame Material Anodized aluminium alloy Max.Output Current(Imax) 15 A 15 A J-Box IP65 Max.Series Fuse Rating 15 A 15 A Cable PV1-F 1*6.0 mm2/950 mm Module Efficiency 16.16% 16.47% Connectors MC4 Output During Standby Standard Packaging 26 pieces (power optimizer disconnected 1 V Module Pieces from inverter or inverter off) per Container 728 pieces(40'HQ) PV SYSTEM DESIGN TEMPERATURE CHARACTERISTICS Specification Data 1 ph 8 Temperature Coefficient(Pmax) -0.41%/°C EU 3 ph 16 Temperature Coefficient(Voc) -0.31%1°C Min.String Length 3 ph-MV 18 Temperature Coefficient(Isc) 0.053%/°C US 1 ph 8 Nominal Operating Cell Temperature 45±2°C 3 ph(280 V) 10 1 ph 20 19 STANDARD COMPLIANCE EU 3 ph 43 42 EMC FCC Part15 Class B, Max.String Length 3 ph-MV 49 48 IEC61000-6-2,IEC61000-6-3 1 ph 20 19 PV Optimizer Junction Box EN50548,UL3730,IEC2109-1 US 3 ph(280 V) 23 22 (class II safety),UL1741 1 ph 5250 Fire Safety VDE-AR-E 2100-712:2013-05 EU 3 ph 11250 Max.Power 3 ph-MV 12750 PARTNER SECTION per String(W) 1 ph 5250 US 3 h(280 V) 6000 Parallel Strings of Different Lengths Yes Parallel Strings of Different Orientations Yes Operating Temperature -40°C—+85°C Max.System Voltage 1000 V(IEC)/600 V(UL) Application Classification Class A Type 1(UL1703)/ Fire Rating Class C(IEC61730) Scan this QR-code to discover solar ❑■ 0 E■ Power Tolerance 0-+5 W projects built with this module Fi.e4,,,,, CANADIAN SOLAR INC. August 2015.All rights reserved, PV Module Product Datasheet V5.3_EN ❑� .U•- solar - • • � SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 tower 0, , ��` F years Mao atAti Viv o'er ;• _ 1� °/•aazioA i PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar - • • z SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for 60-cell modules) (for high-power (for 72&96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Power1�1 300 I 320 I 400 1 405 F W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 I 8-80 I 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 I 11 I 10 Adc Maximum DC Input Current 12.5 I 13.75 I 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current I 15 Adc Maximum Output Voltage I 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 128x152x27.5/ 128x152x35/ 128x152x48/ mm/in 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 Weight(including cables) 770/1.7 I 930/2.05 I 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % I'I Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 I W Parallel Strings of Different Lengths or Orientations Yes mit is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE ETA ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice. ci) solar cc W SolarEdge Single Phase Inverters CC For North America W SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US Z s I everter .12,25' WVear my arra , 'aIiaFS 10 1 , 111 d I t Orr'7E7 The best choice for SolarEdge enabled systems • Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) — Small, lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS- ISRAEL www.solaredge.us solar - • • z Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US I SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A-US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA 10000 @240V • Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 @240V 10950 @240V I AC Output Voltage Min:Nom:Max.ltl ✓ 183-208-229 Vac Ir AC Output Voltage Min:Nom:Max.ltl 211-240-264 Vac AC Frequency Min.-Nom.-Max.l'i f 59.3-60-60.5(with HI country setting 24 @ 208V etting 57-60-60.5) Hz 48 @ 208V Max.Continuous Output Current 12.5 I 16• 21 @ 240V 25 I 32 42 @ 240V I 47.5 1 AA • GFDI ll 1 ll Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes r Yes INPUT Recommended Max.DC PowerlZl 3750 1 4750 6250 7500 9500 12400 14250 W .(STC) • . Transformer-less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Currentl3l 9.5 f 13 16.5 @ 208V I 15.5 @ 240V f 18 f 23 I V 3 33 @208 240V I 34.5 1 Adc • Max.Input Short Circuit Current F 45 Adc • Reverse-Polarity Protection Yes . Ground-Fault Isolation Detection 600ko Sensitivity • Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % • CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5 1 98 @ 240V 97.5 @ 240V Nighttime Power Consumption F <2.5 F <4 W ADDITIONAL FEATURES Supported Communication Interfaces I RS485,RS232,Ethernet,ZigBee(optional) •Revenue Grade Data,ANSI C12.1 Optional141 Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed') STANDARD COMPLIANCE Safety I UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards F IEEE1547 Emissions I FCC partly class B A INSTALLATION SPECIFICATIONS AC output conduit size/AWG range I 3/4"minimum/16-6 AWG I 3/4"minimum/8-3 AWG 1 DC input conduit size/#of strings/ AWG range 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.Sx12.5x10.5/775x315x260 in/ • .(HxWxD) 775x315x172 775x315x191 mm . • Weight with Safety Switch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg Cooling I Natural Convection F Fans(user replaceable) F Noise <25 [ <50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version availablelb)) "F PC Range , Protection Rating NEMA 3R iri For other regional settings please contact SolarEdge support. Pi Limited to 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where it is below 77'F/25°C. For detailed information,refer to http://www.solaredge.us/files/pdfs/inverter_dc_oversizing_guide.odf MA higher current source may be used;the inverter will limit its input current to the values stated. 141 Revenue grade inverter P/N:SExxxxA-US000NNR2 Isi Rapid shutdown kit P/N:SE1000-RSD-S1 (6)-40 version P/N:SExxxxA-US000NNU4 4,0 EMI RoHS ©SolarEdge Technologies,Inc.Al rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2014.V.01.Subject to change without notice. Ez Roof (friount. . . Engineered and Designed for easy installation. Our roof mounting system is water tight and durable for any composite/shake roof! {r A NM 4-t n x ; '--A: --: i 1.• ,. yam ;,% � Serrated L Foot allows for Versatile aluminum base for Flashing designed to redirect rail mounting on either multiple configurations. water flow. side. —. [121,1i Istrop. Ez Mount L-Foot Kit for Shingle Roofs Kit# K10068-001 All kits come complete with the following parts: i?� 1-Lag Bolt SS 5/16 x 4 1-Al Shoe Part#B15015-002 1 Part#A20065-001 1-Ez L Foot `T .011, Part#A20064-001 011111 fa 1-Flashing IR 1- Hex Cap ."",--- 1- Bolt 3/8-16 x 3/4" Pal t#A20066-001 Part#A20052-001 1- Flange Nut g3/8" Also available: .11 • • 1905 E 5th St., Ste. A Vancouver, WA 98661 Phone: 360-844-0048 www.sunmodo.com