Line Diagram 03/28/17
Crow Residence 8.745 kW Utility Interactive Photovoltaic
1250 Ptarmigan Road System
Vail, CO 81645 Modules: 33 Canadian Solar CS6P-265P-SD
Voc=37.7V
Isc/Imax= 15A
Array mounted on roof Optimizers: 33 integrated SolarEdge P300
4#10 PV Wire 33 Canadian Solar CS6P-265P-SD Solar Panels
1#6G Bare Cu 33 integrated SolarEdge P300 DC Optimizers 2 String X 16/7 Modules/Inverter
Conductors in Free Air Inverter: SolarEdge SE7600A-US
Operating Voltage: 350V
1 2 3 ••• 16 Operating Current: 15A
Pass-Thru
Box - ---- _i
Max System Voltage: 500V
-
Located on �� ��____� t __i Max Output Current: 30A
roof Placard on meter and main panel stating
"Photovoltaic System Connected" o
per Holy Cross specifications Tilt Angle:22.62
17 18 19 33 Array Azimuth: 120°
Net Meter on Production: 11,778kWh/yr
+1-60' northwest
3/"C EMT/FMC LDI
i t-1 1=1• side of
2#10 THWN-2 , garage I
1 #10 Ground Notes:
-See Calculation Sheet for conductor
+/-10'
3/"C EMT/PVC/FNMC/NM-B -sizing.
3#8 THWN-2 All conductors are copper unless
1 #8 Ground otherwise noted.
• - Inverter listed (UL-1741)to de-
Production energize upon loss of utility voltage
• Meter housing per NEC 690.61.
• with lever Backfeed
- Inverter has integral ground-fault
bypass Breaker:
adjacent to 40A protection per NEC 690.5
meter ^ ^ 2P -240V 1 Phase Service Panel rating
Inverter w/ 44 I ' 240V of 200A (bus rating 200 amp and 200
Integrated DC Disconnect ^ ^ Main disconnect)to accommodate
SolarEdge SE7600A-US DC Grounding r,
40A+ 200A=240A supply(up to
NEMA 3R/Arc Fault/Rapid Shutdown Electrode Conductor 120% of connected power sources
Max AC Output:32A @ 240V solid bare#6 Cu
Located in garage per NEC 250.66(C) Service Panel from residential installations per NEC
•• In garage 690.64(B)(2))