CEILING PLAN KEY NOTES: CEILING PLAN GENERAL NOTES: lei 11°
5. CEILING HEIGHTS INDICATED ARE APPROXIMATE AND SHOULD 03/29/17
OREPLACE EXISTING DECORATIVE FIXTURE AS SELECTED BY DESIGNER. 1 . NEW LIGHTING AND LIGHTING CONTROL SYSTEM THROUGHOUT BE VERIFIED BY CONTRACTOR WHERE APPLICABLE.
UTILIZE EXISTING ROUGH-IN LOCATION (U.O.N.) AND SWITCHING. UNLESS NOTED OTHERWISE. COORDINATE REQUIRED WIRING
WITH FIXTURES AND LIGHTING CONTROL SYSTEM. 6. CONTRACTOR SHALL MAINTAIN REQUIRED ACCESS TO ALL
O NOT USED. ABOVE-CEILING EQUIPMENT, REORIENT/RELOCATE ACCESS
2. SEE ELECTRICAL DRAWINGS FOR CIRCUITING. COORDINATE PANELS AND/OR EQUIPMENT AS REQUIRED.
EXISTING SWITCH BANK/KEYPAD/CONTROL LOCATION TO CIRCUITING AND CONTROLS WITH LIGHTING CONTROL
3OACCOMMODATE NEW COMPONENTS AS SHOWN, COORDINATE VENDOR. 7. COORDINATE INTEGRATED MILLWORK LED LIGHTING INCL.
RELOCATION IF REQUIRED, COMPONENTS AND FUNCTION WITH OUTLET/TRANSFORMER LOCATIONS WITH KITCHEN DESIGNER.
LIGHTING CONTROL VENDOR AND OWNER. 3. SEE LIGHTING PLANS SHEETS L-000 AND L-100 FOR ADDITIONAL
LIGHTING AND CONTROLS INFORMATION.
PROPOSED KEYPAD/CONTROL LOCATION. COORDINATE LOCATION UNIT 9203
OAND REQUIRED COMPONENTS WITH LIGHTING CONTROL VENDOR 4. FIRE SPRINKLER CHANGES SHALL BE DESIGNED BY THE FIRE
AND OWNER. COORDINATE WIRING REQT'S WITH EXISTING SYSTEM SPRINKLER CONTRACTOR (ALL STATE FIRE PROTECTION) AND
AND NEW FIXTURES. SUBMITTED BY DEFERRED SUBMITTAL IN ACCORDANCE WITH ALL R EMO D E L
TOWN OF VAIL AND BUILDING DEPARTMENT REQUIREMENTS.
ORELOCATE SUPPLY DIFFUSER AS REQUIRED, RECONNECT DUCTWORK
5 TO SAME AIR HANDLING UNIT. UNIT 9203
NEW AND/OR RECONFIGURED RETURN AIR SLOT AS REQUIRED. FOUR SEASONS
CONSTRUCT IN SIMILAR FASHION TO EXISTING RETURN AIR OPENINGS RESORT & RESIDENCES
/
AND MAINTAIN RETURN AIR REQUIREMENTS.
� r VAIL, CO
• :...:
O NEW SUPPLY DIFFUSER, MAINTAIN EXISTING CFM AS REQUIRED. 4.
i 1 fl CLIENT:
' " Tim & Nancy." I C +8 -� i...,; BJH—Z yBuese
O NEW RETURN AIR GRILLE IN FACE OF SOFFIT. 1 Unit 9203
11
FOUR SEASONS VAIL
0 NEW LIGHT COVE. 1 �1 BED 2 � 11
� 1 Vail Road
�_ �� I VAIL, CO 81657
RECONFIGURE/RELOCATE FIRE SPRINKLER AS REQUIRED PER GENERAL 110
10 O ARCHITECT:
> >>
NOTE #6. BED Creative Design g i t
3 C ea essoc a es
—
108 EXISTING +11 434 BROADWAY, 5TH FLOOR
O - - I NEW
YORK, NY 10013
11 COORDINATE POWER & CONTROL REQUIREMENTS FOR NEW RANGE I I I L3 2'•:1-fiR; .,. . -.. ..,.... :
1
HOOD WITH KITCHEN DESIGNER. t. 212-748-8900
EXISTING '— "
WESTERN US
I
+9 1 �mI `. 4700 E BROMLEY LN,SUITE 105
12 NEW EXTERIOR LOUVER FOR RANGE HOOD EXHAUST. 4 E3 ®� , N BRIGHTON, Co 80601
+9'-1 " 0 _ _ JS(Eji'— E MUD ROOM :i i ii t. 646-747-2171
�_� pA2 �_� c. 917-756-0057
13 NEW EXTERIOR LOUVER FOR MAKE-UP AIR UNIT INTAKE . 4 Al Al FSD O 113 / 111, dsorenson@ralcompanies.com
O • ® , p
r
L4
D 0 Q
+8'-1 " I +8'—0" O ' " S D INTERIOR DESIGN:
> „ O Duet Design Group, LLC
+8 —0 +7 -10 N N 901 ACOMASUITE200
Al I\IA2 -A1 I/IA2 -Al ® Al- j = n O I. I
I DENVER, CO 80204
0 O® O `,. t. 303-783-9327
POWDER Ll
g g p
., ® miran a ue e .com
si n rou
® O SD O ® 114 MECH/PLUMBING ENGINEER:
, n „ - - - <�q2 'Al
,vi =i
> Rader Engineering
Al Al- SIE)
iV N
g g
Al Al
( I I.oA2 AlOAl® O Z.
•:• ' I PO BOX 8610
,I _ _ lATH 2 1 ' +8 —0 OA2 .I
AVON, CO 80620
mial L2 +7'—g"
— ,, 1 1 1 IgA1 A2 ///��///////
� 'I t. 970-845-7910
TBATH 3 Al� �A2 ,'-'A1 „ O 7' 7" L1C,— •L1i SKI BryanH@raderengineering.com
CEILING PLAN LEGEND: Al� ''='A1 ''=�q13 Al''-' 109 Al� Al� +7 -8 CLOSET
+8'-0" CO ''='A1 115 I ELECTRICAL ENGINEER:
4 _ 3
N N
C Incorporated
® _ 1C 3S
p
- SINGLE POLE SWITCH O r MASTER _ 000 �'='Al A2d ® O — I 1 3212 WEST 45TH AVENUE
C1 I .
" : • L2 BATH i_iA1 pi ' 4�IlO .v DENVER, CO 80211
r' cn . W Al W Al ;:
THREE WAY SWITCH ` .<•.o, .
L2 106 L31 '� • • 0
HALLWAY
------------------------------------ 112
00000 t303-480-5144
--- .., Ali� � .dmo j
theresa@c3sengineeringinc.com
JS DOOR JAMB SWITCH Al''-' ''-'A1 L5 L5 ' '`
il BHT
la
1 II LA I I LIGHTING DESIGN:
AlF ® ® 000 AlEAl''' '''Al Al'''
Q KEYPAD ��
186 Lighting Design Group, Inc.
O ' " HALLWAY O �> L5 ^ ^ T 1200 BANNOCK STREET
ifi RF TABLETOP KEYPAD +7 -11 SITTING A2
O Q <� ''-'A1 Ago oA2 DENVER, CO 80204
+�,—�„ ' ® <�A2 1107 I O +8, 1 " 103 HA2 8 A2 ENTRY z t. 303-534-5350
// 7," Al L4 +8'-0'' <1 �_� �_� �_� �_� �> 100 — gmackell@l86group.com
CI RF LAMP DIMMER - PLUG INTO HOT OUTLET A2 Al Al Al Al A2 11
O O 0
KITCHEN DESIGN:
O4 ® EDT �.,
- NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT ^ ' ®� ® Al��® A� -� " A2a aA2 ® exquisite kitchen design
OA2 O B O O / O O + I -10 O 3C 601 SOUTH BROADWAY SUITE F
ALIGN DENVER, CO 80209
o ® NEW RECESSED DOWNLIGHT -� -� i
Al Al , „ Al Al 004 j 303-282-0382
+g -0 -
L5 �_�Al �_�Al �_�Al �_�Al �_�AlAl / LII ; -- mikalo@myekdesign.com
o NEW RECESSED ADJUSTABLE ACCENT $ b SII O - - - 0 - - lob L1 Ll O O
o O • L1 1 Al Al Al 1 Al Al L4 10 ISSUE DATE COMMENT
o NEW RECESSED WALL WASH • - TI -
41 O i_iA1 O Al� +8'-8'' +7 —8 i_i O L
W 9 NEW WALL MOUNTED FIXTURE ® 4 Al A2 T
1 2/22/17 FOR PERMIT
MASTER LIVING
P 0 NEW HANGING PENDANT OR CHANDELIER BED ROOM LF 1
< 105 '' e Al ,_i Al 104 NJ i_i Al i_i Al i_i Al i_i Al
E - LOW VOLTAGE OR LED STRIP (�
�2 , Al Al I
<� �, + J'-0" - '-'Al ''-'A1 ''-'A1 ''-'A1 ''-'A1 DINING i=iql I ■
A2 `J '-'A1 ROOM 0 0 KITCHEN 11
I I RECESSED LINEAR LIGHT P 102 ®Al 101
1 CIO
48' O SURFACE-MOUNTED LINEAR LIGHT A2 S� S� '=' ' " '=' 1
Al+8 -8 Al 11
I CI DATE: 02/22/2017
0 CEILING FIXTURE, EXISTING U.O.N. 1
''-'A1 ''-'A1 Al�• ® Al® aiAl Al® Al® Al® u SCALE: AS NOTED
LI
I 0 WALL MOUNTED FIXTURE, EXISTING U.O.N. O HI Elm ''A1 '-'Al ElAllgAl ElAl ''='A1 ''='Al 1 JOB #: 16-27 ( �a
SD 1
SD SMOKE DETECTOR, EXISTING U.O.N. '' ®4 O ALIGN,TYP.
Ll DRW BY: VK
0
O RECESSED SPRINKLER HEAD, EXISTING U.O.N. — ''-'A1 ''-'A1 �A2 ''-'Al ® -lc M1 Ll , „ I ® CHK BY: VK I
• +9'-1 " 0 0 •O 0 +9'-1 " . .:', +9'-1 0 3J�O L31 SEAL 8 SIGNATURE:
Q WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N. • 1. Ll
Es VMCVCS / 0 . c - •
SPEAKERERGCEILINGCOICE OR WALL MOUNTED.UNIATION EXISTING(E ) YSTEM U.O.N. / ISI ,
rs
RECESSED FIXTURE, EXISTING U.O.N. �' �'
// _ / i / / i / / / lXr. k;
� 13 12 - � 1110.7-',:_i4soc,
• RECESSED FIXTURE, EXISTING U.O.N. PrirrAgrAM
/
/ � I PHASE 2 �/ 42417
�
Z RECESSED FIXTURE, EXISTING U.O.N. O
; t
WALL LEGEND: ' ,S
RECESSED FIXTURE, EXISTING U.O.N.
HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D.
® EXISTING EXHAUST FAN, NO CHANGE / REFLECTED CEILING PLAN TITLE:
/////////// HATCH INDICATES NEW WALL CONSTRUCTION. DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD U.O.N. INTERIOR WALL CONSTRUCTION SHALL BE 20GA 1
/\ ACCESS PANEL CFMF U.O.N. I
REFLECTED CEILING
PLAN
SHEET:
A-301 06 OF 22