HomeMy WebLinkAboutB17-0027_E-200.pdf i ti OF go ff %-ligitir IP Z' 4. ' ilaD716 / / Z GENERAL NOTES - POWER: ADDITIONAL LEGEND - POWER: 03/29/17 1. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS,ELEVATIONS, NOTE: UNLESS OTHERWISE NOTED,ALL NEW RECEPTACLES / // DETAILS,ETC..VERIFY MOUNTING HEIGHTS OF DEVICES AND ENSURE SHALL MATCH EXISTING ELEVATIONS(AFF) / / // MINIMUM 24"HORIZONTAL SEPARATION PER UBC IN FIRE RATED DEMISING WALLS. PROVIDE FIRE-STOP OR ADDITIONAL RATED GYP I I I I I I I BOARD AS REQUIRED.COORDINATE WITH FIRE DEPT./INSPECTOR AND T TV/COAXIAL RECEPTACLE • 6 0. ' / ED n G.C. DUPLEX WALL RECEPTACLE 4`_ „„.44-1--- ,I I- 2. UNIT LIGHT FIXTURES TO BE SELECTED BY OWNER AND RATED FOR INSULATED CEILINGS WHERE NEEDED. ENSURE PROPER LOCAL III; FLOOR DUPLEX RECEPTACLE SWITCHING. LIGHTING FURNISHED BY E.C.TO BE COORDINATED WITH 3IE FLOOR FOURLEX RECEPTACLElI > < CEILING TYPES,MECHANICAL WORK,STRUCTURAL MEMBERS,ETC. BED 2 i - VERIFY FINISHES AND LOCATIONS OF CONTROLS. IT FOURPLEX WALL OUTLET 110 ,R)` e 3. COORDINATE PRE-WIRING OF T.V.COAX AND TELEPHONE JACKS WITH t 220V WALL RECEPTACLE I I I 1 G.C.AND OWNER. VERIFY ALL WALL LOCATIONS WITH ARCHITECT TELEPHONE&DATA JACK = BED 3FE- / / LiNIT 9203 PRIOR TO ROUGH IN. 108 / 4. PROVIDE RECEPTACLE LOCATIONS AND SPACING PER N.E.C.210-52 DATA JACK // THROUGHOUT. FIELD ADJUSTMENTS/MEASUREMENTS ARE REQUIRED TTELEPHONE JACK = C� i REMODEL TO COMPLY. COORDINATE ADDITIONAL STUD WALL BRACING IF ® IN-FLOOR TELEPHONE JACK F›- - _ _ REQUIRED FOR RECEPTACLE PLACEMENTS WITH G.C. IF APPLICABLE, I NEW . VERIFY EP FLOOACLES OUTLETLOCATIONS WITH ARCHITECT. PROVIDE GFI =E HARDWIRE BOX LOCATION-AS NOTED,EXISTING H SUB PANEL u RECEPTACLES WHERE REQUIRED BY CODE PER NEC 210.8. UNIT 9203 -0 0 A MUD ROOM PP-CD10A 5. PROVIDE ARC FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING NOTE: NOT ALL EXISTING RECEPTACLES ARE SHOWN. THOSE SHOWN i • UNITS PER NEC 210.12. FAMILY ROOMS,DINING ROOMS,LIVING ARE FOR REFERENCE AND ARE IN THE AREA OF CONSTRUCTION. "CU-A" 113 FOUR S EAS O N S DASHED FIXTURES INDICATES EXISTING TO BE REMOVE/DEMOLISHED w 1 I- / "PP CD10" ROOMS,PARLORS,LIBRARIES,DENS,BEDROOMS,SUNROOMS, ED. _ _ / RESORT & RESIDENCES I AREASRECREATION S ALL BEEMS,CLOSETS,HALLWAYS,OR SIMILAR PROTECTED BY A LISTED ARC-FAULT CIRCUIT OR OR=NEW FIXTURE (R)=RELOCATED = 1, P 0 "CU-A' (UW D VAIL, CO INTERRUPTER TO PROVIDE PROTECTIONVERIFY WITH LOCAL AUTHORITY AV NGEF JURISDICTION IF EXISTING = %THE BRANCH CIRCUIT. (N) (N ry- L E BRANCH CIRCUITS SHALL COMPLY WITH NEC 210.12. N. j CLIENT: DETAIL NOTES - POWER: / \ ill 1 PP CD10A-3 i -I / lEl Tim & Nancy Buese 6. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC 410.16. _ , /������� s, �� "fl, A / POWDER 1> RE-USE EXISTING CIRCUITRY MADE AVAILABLE THROUGHI • • Unit 9203 7. ALL ELECTRICAL DEVICES AND LIGHT FIXTURE MOUNTING HEIGHTS DEMOLITION/RELOCATION. MI) 114 ® FOUR SEASONS VAIL SHALL COMPLY TO THE"FAIR HOUSING ACT":DUPLEXES+15"A.F.F., H ,i41),„„_ / HEAT MAT eF 1 1 ��® 1 Vail Road SWITCHES AT+46"A.F.F.VERIFY WITH OWNER. CONNECT TO EXISTING 120V.RECEPTACLE/CIRCUIT. _ (N) • 1 \WAY GFCI VAIL, CO 81657 1 / BATH 2 FCU H" 3 (R) 8. FOR NEW RECEPTACLES,PROVIDE TAMPER RESISTANT RECEPTACLES BATH 112 NEW LOCATION FOR POWDER ROOM RECEPTACLE. I �, 0 111 // ////:'ExGi-Alt ARCHITECT: THROUGHOUT DWELLING UNIT AS REQUIRED BY NEC 406.12 LL RE CONNECT TO EXISTING 120V.CIRCUIT. _ [411 / 109 1> JHEAT AT / Creative Design Associates 9. PROVIDE ACCURATE AND LEGIBLE PANEL INDEXES IDENTIFYING NEW HEAT MATIN MASTER BATHROOM. RE USE EXISTING 1 o (N) " _ 434BROADWAY, 5TH FLOOR SPECIFIC PURPOSE OR USE OF CIRCUIT BREAKERS PER NEC 408.4. I1 0 ST�RILLE CIRCUIT(PP-CD10-40) L ' ft 2J * PP CD 0A-1 //////ti,,. W/VO CUM= NEW YORK, NY 10013 / CONTTOL t. 212-748-8900 4a PROVIDE ADD ALTERNATE PRICING: NEW HEAT MATIN =//////////////////////// 2 �. _ mgm Gib HALLWAY �� o E WESTERN US SHOWER. CONNECT TO EXISTING HEAT MAT CIRCUIT IN MASTER = o L©J r COSET UITE 105 MASTER BATHROOM. a 41 n - ©© BRIGHTON, CO 80601 106 �" 115 NEW HEAT MAT IN THIS BATHROOM. °;_ [`� I T L t. 646-747-2171 0°MINN 111 (N) i I _ NEW MAKE UP AIR UNIT.208V.,34),16KW. -. "CU A° _ • c. 917-756-0057 . >. IIT (N) (M (N) I I I dsorenson@ralcompanies.com (N) - SITTING ///////A NEW SUPPLY FAN"SF-1"120V.,1 4),301 WATTS. REFER TO = "CU-A" "FCU-B' 2 1 103 INTERIOR DESIGN: MECHANICAL DRAWINGS FOR INTERLOCKING INFORMATION (N) WITH"MAV 1"AND"KEH 1" /G-1" Duet Design Group, LLC • 901 AROMA SUITE 200 > "KEH-1"120V.,14),8.5 AMPS = EXHAUST DENVER, CO 80204 //////////////////// -Q ENTRY t. 303-783-9327 PROVIDE NEW FLUSH MOUNTED PANEL"PP CD10A". 7 100 - miranda@duetdesigngroup.com PROVIDE 18 CIRCUITS PANEL. COORDINATE LOCATION WITH / L/�/Jjf /////////////////// // OWNER AND ARCHITECT. = / MECH/PLUMBING ENGINEER: EX NG FIREPLACE TO BE REPLACED TH NEW FIREPLACE 10 UNIT. RE USE EXISTING CIRCUITS FOR GIN TER. COORDINATE ////// r������������������������������������/ Rader Engineering EXACT REQUIREMENTS WITH VENDOR PRIOR TO DEMOLITION = j j j PP CD10 1 PO BOX 8610 //////// / ., AVON, CO 80620 AND INSTALLATION. ����� Q�i.WINE n , t. 970-845-7910 v LIVING BryanH@raderengineering.com B 4 ROOM FRIDGE -- 104 PP CD10 16 ELECTRICAL ENGINEER: _ 4_; SA-1" I 1� C3S Incorporated H 1737 CENTRAL STREET SUITE 201 // 41 SOUND `� 1 PP CD10-26 DENVER, CO 80211 1 ATTENUATOR MASTER 2 PP CD10-14 i 1I t. 303-480-5144 w 1 BED / Io®e IVA' atheresa@c3sengineeringinc.com 105 % &E (N) FREEZER Vii 1 FIREPLVELIGHTING DESIGN: \ ,,., DRAWERS W/ICE (N) /` ` MAKER i RANGE 186 Lighting Design Group, Inc. _ „ DINING KITCHEN KEH-1' INTI 1200 BANNOCK STREET (N) ROOM 7 "SF-1" 101 KITCHEN IfAll 1�� PP�CD10 38 DENVER, CO 80204 (N)I.—/ EXHAUST. 1� ftt 102 , F 1 t. 303-534-5350 10 PP CD10A-8 HOOD' ° ca I 1,1 IL- HOOD gmackell@186group.com B > "MAU-1" IOU9 (N) > �,I PP CD10 42 KITCHEN DESIGN: ,,K rilE ®® exquisite kitchen design I PP CD1OA 2,4,6 _-(11 601 SOUTH BROADWAY SUITE F (N) © •� DENVER, 303-282-0382 mikalo@myekdesign.com MW DW d. 7 1 GFCI ° ° C PP CD10 24 (N) (N) (N) �•FCI GFC (IPcu..iii (N ISSUE DATE COMMENT II' 0 J L 4 I I QD I II 1 1 I li //'/ j / `/ / PP�CD10-29 > `� 0 1 2/22/17 FOR PERMIT / / PP CD10-27 PP CD10-30 /'• %' /'% %' /2/ ,/ /// / // /___ //--- , Z' /' /'/' //'/' %/'/' ////1_%_/ - - -- L 1 ' TT7-- /-,-----/ --J 1 . J I-ll J DATE: 22 2 2 17 0 0 SCALE: AS NOTED TED POWER PLAN - UNIT 9203 El JOB #: 16-27 SCALE: 1/4"= 1'-0" EiiiiiimiiiIRSERE DRW BY: C3S, TNS EiiiiEEMEHRES CHK BY: JMM SEAL & SIGNATURE: 1 ?, + +0i ,,4 , . �. .��� #iii' it `4*-1 TITLE: POWER PLAN SHEET: E-200 19 OF 22