Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0027_L-000.pdf
k4 OF X 4 , ii:46(41 Is V 03/29/17 COLOR LEGEND MR16 LEGEND GENERAL NOTES 1.THE ELECTRICAL CONTRACTOR SHALL INSTALL FIXTURES SPECIFIED BY 186 LIGHTING UNIT 9203 DESIGN GROUP, INC.(186). ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186. SP 10 DEGREE SPOT BEAMSPREAD UNAPPROVED SUBSTITUTIONS ARE SUBJECT TO REPLACEMENT WITH SPECIFIED FIXTURES LOW VOLTAGE KEYPAD; FIREPLACE; MOTOR AT THE ELECTRICAL CONTRACTOR'S COST. NFL 25 DEGREE NARROW FLOOD BEAMSPREAD R E M O D E L FL 40 DEGREE FLOOD BEAMSPREAD 2. UPON RECEIPT OF DESIGN DOCUMENT SET, THE ELECTRICAL CONTRACTOR IS TO VERIFY SYSTEM HOMERUN LOAD ALL FIXTURE LEAD TIMES WITH DISTRIBUTOR,AND GET APPROVAL FROM THE GENERAL WFL 60 DEGREE WIDE FLOOD BEAMSPREAD CONTRACTOR THAT THESE LEAD TIMES ARE ACCEPTABLE. IF ANY FIXTURE LEAD TIMES ARE NOT APPROVED BY THE GENERAL CONTRACTOR,THE ELECTRICAL CONTRACTOR IS TO UNIT 9203 SYSTEM DIMMER/HYBRID KEYPAD CONTACT 186 IMMEDIATELY FOR ASSISTANCE WITH DECREASING LEAD TIMES OR FOR DIFF DIFFUSING LENS ALTERNATE SPECIFICATION. ELECTRICAL CONTRACTOR IS TO FOLLOW THIS PROTOCOL FOUR SEASONS THROUGHOUT PROJECT AS NEW DRAWINGS AND SPECIFICATION SETS ARE ISSUED. RESORT Sc RESIDENCES - NON-SYSTEM DEVICES SOFT SOFT FOCUS LENS 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLIANCE OUTLETS, LIN LINEAR SPREAD LENS DISPOSALS,AND POWER FOR SYSTEMS NOT SHOWN ON 186 PLANS(IE. POWER FOR HVAC VAIL, CO EQUIPMENT, POOL EQUIPMENT, ETC.) INTERIOR DESIGNER IS TO SUPPLY APPLIANCE POWER OUTLETS FROST FROSTED LENS PACKAGE FOR ELECTRICAL REQUIREMENTS. GENERAL CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR SYSTEMS NOT SHOWN ON PLANS. AUDIO/VIDEO CONTRACTOR CLIENT: CLR CLEAR LENS IS TO SUPPLY ALL POWER REQUIREMENTS FOR ALL A/V EQUIPMENT. ELECTRICAL Nancy Tim & Buese CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND GFIUnit LOUV HONEYCOMB LOUVER REQUIREMENTS. FOUR SEASONS VAIL 4. ELECTRICAL AND GENERAL CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL 1 Vail Road FIXTURE COUNTS PRIOR TO ORDERING. 186 IS NOT RESPONSIBLE FOR ANY RESTOCKING VAIL, CO 81657 CHARGES DUE TO MIS-ORDERING OR CHANGES BY OTHERS AFTER THE INITIAL ORDER. 5. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS ARCHITECT: LEGEND AND RECOMMENDATIONS. Creative Design Associates 434 BROADWAY, 5TH FLOOR 6. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IC,AIRTIGHT,AND NON-IC NEW YORK, NY 10013 FIXTURE LOCATIONS PRIOR TO ORDERING FIXTURES. INSULATION TO BE HELD A MINIMUM OF t. 212-748-8900 3"FROM ALL NON-IC FIXTURES. WESTERN US C-CT} CEILING MOUNTED FIXTURE HOT ELECTRICAL OUTLET 7. ALL FIXTURE HOUSING SLEEVES AND COLLARS THAT HOLD FIXTURE TRIMS ARE TO BE 4700 E BROMLEY LN,SUITE 105 COMPLETELY FLUSH WITH CEILING AT ELECTRICAL TRIM-OUT. TRIMLESS/FLANGELESS BRIGHTON, CO 80601 GFI GFI PROTECTED OUTLET RECESSED LIGHTS ARE TO BE MOCKED UP BY THE ELECTRICAL CONTRACTOR PRIOR TO t. 646-747-2171 P lff HANGING PENDANT OR CHANDELIER INSTALLATION. c. 917-756-0057 WP P • LONG HANGING PENDANT OR CHANDELIER,VERIFY FEED LOC. GFI (p WEATHERPROOF GFI OUTLET 8. ELECTRICAL CONTRACTOR IS TO NOTIFY 186 IF ANY FIXTURE LOCATIONS MUST MOVE dsorenson@ralcompanies.com MORE THAN SIX INCHES DUE TO FIELD CONDITIONS. INTERIOR DESIGN: WALL MOUNTED FIXTURE (P 1/2 SWITCHED OUTLET 9. ALL SCONCE AND CLOCK OUTLET LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE. Duet Design Group, LLC W 0EXACT LOCATIONS AND HEIGHTS OF WALL SCONCES AND CLOCK OUTLETS FOR PICTURE 901 ACOMA SUITE 200 FULLY SWITCHED OUTLET LIGHTS ARE TO BE VERIFIED WITH THE INTERIOR DESIGNER AND/OR OWNER. DENVER, CO 80204 CO CLOCK OUTLET FOR PICTURE LIGHT t. 303-783-9327 10. ALL LED STRIP INSTALLATIONS ARE TO BE INDIVIDUALLY FED IN LENGTHS NO LONGER HOT FLOOR OUTLET THAN THE MAXIMUM LENGTHS RECOMMENDED BY THE MANUFACTURER. ELECTRICAL AND miranda@duetdesigngroup.com O M © i RECESSED DOWNLIGHT, ROUND OR SQUARE GENERAL CONTRACTOR ARE TO WORK TOGETHER TO ENSURE THERE ARE NO VISIBLE WIRENUTS OR ELECTRICAL CONNECTIONS. MECH/PLUMBING ENGINEER: 0 6 O a RECESSED ADJUSTABLE ACCENT, ROUND OR SQUARE • 1/2 SWITCHED FLOOR OUTLET Rader Engineering 11.ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS. WHERE BEAMSPREADS ARE PO BOX 8610 • FULLY SWITCHED FLOOR OUTLET NOT SPECIFIED,SUPPLY WIDEST BEAMSPREAD AVAILABLE FOR PARTICULAR LAMP TYPE. © MINI-RECESSED DOWNLIGHT OR PUCKLIGHT AVON, CO 80620 12.ALL WIRING IS SHOWN SYMBOLICALLY ON PLANS. ACTUAL REMOTE t. 970-845-7910 O RECESSED WALL WASH, ROUND OR SQUARE HOT QUAD FLOOR OUTLET TRANSFORMER/DRIVER LOCATIONS AND HOMERUNS ARE TO BE DETERMINED BY ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR. ALL REMOTE BryanH@raderengineering.com TRANSFORMERS/DRIVERS SHALL BE TOROIDAL AND MOUNTED IN A LOCATION REMOVED ELECTRICAL ENGINEER: L T� 7 TRACK LIGHTING • 1/4 SWITCHED QUAD FLOOR OUTLET FROM THE ROOM'S AIRSPACE SUCH AS AN ATTIC, CABINET, OR CRAWLSPACE, UNLESS C3S Incorporated OTHERWISE NOTED. 3212 WEST 45TH AVENUE 7 7 7 7 MONOPOINT HEAD QUAD OUTLET 13.ALL SWITCHED OUTLETS SHOWN ON PLANS SHALL BE WIRED SUCH THAT THE OUTLET DENVER, CO 80211 MAY BE SWITCHED AT ANY TIME IN THE FUTURE. VERIFY ACTUAL OUTLETS TO SWITCH WITH t. 303-480-5144 DUAL HEADED MONOPOINT 1/4 SWITCHED QUAD OUTLET OWNER. ALL HALF-SWITCHED OUTLETS ARE TO HAVE SWITCHED SIDE AND HOT SIDE FED FROM SAME BREAKER. theresa@c3sengineeringinc.com 220V 220V OUTLET 14. EXHAUST FAN LOCATIONS ARE SHOWN SYMBOLICALLY ON THE PLANS. VERIFY EXACT LIGHTING DESIGN: JB JUNCTION BOX EXHAUST FAN LOCATIONS WITH MECHANICAL CONTRACTOR. 186 Lighting Design Group, Inc. 1200 BANNOCK STREET JB 12V OR 24V ROUGH-IN JUNCTION BOX ®GD GARAGE DOOR OUTLET 15. MOTION SENSORS SHALL BE WALL-MOUNTED AT STANDARD SWITCH HEIGHT UNLESS DENVER, CO 80204 12/24V OTHERWISE NOTED. t. 303-534-5350 0 4-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX MOTION SENSOR 16.ALL LOADS TO BE LANDED ON CONTROL DEVICES IN ORDER DRAWN ON PLANS. gmackell@l86group.com RGB JB 5-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX SWITCH 17.CENTER LINE OF TYPICAL SWITCH AND WALLBOX DIMMER BOXES TO BE AT 48"A.F.F. KITCHEN DESIGN: RGBW CENTER LINE OF TYPICAL CONTROL SYSTEM KEYPADS TO BE AT 54"A.F.F.(EXCEPT AT exquisite kitchen design BEDROOM HEADBOARD LOCATIONS,ABOVE COUNTERS,AND OTHER NON-TYPICAL KEYPAD 601 SOUTH BROADWAY SUITE F O FP FIREPLACE IGNITION 3-WAY SWITCH LOCATIONS)VERIFY WITH OWNER,ARCHITECT,AND INTERIOR DESIGNER. ELECTRICAL CONTRACTOR AND AN CONTRACTOR TO VERIFY ALL KEYPADS BESIDE BEDS ARE INSTALLEDCD DENVER, CO 80209 303-282-0382 SHADE MOTOR/WINDOW MOTOR4 4-WAY SWITCH CLEAR OF BED HEADBOARD. mikalo@myekdesign.com 18. ELECTRICAL CONTRACTOR TO VERIFY DIMMER AND CONTROL LOCATIONS. 0 EXHAUST FANDIMMER D 19.ALL LOADS IN REMOTE DIMMING PANELS TO BE LANDED WHERE SHOWN ON PANEL ISSUE DATE COMMENT SCHEDULE PROVIDED BY LIGHTING CONTROL SYSTEM CONTRACTOR. ELECTRICAL CEILING FAN 3D 3-WAY DIMMER CONTRACTOR SHALL NOTIFY LIGHTING CONTROL SYSTEM CONTRACTOR OF ANY LOADS TABLE OF CONTENTS 1,,,,, CEILING HAVE BEEN MOVED FOR ANY REASON. 1 2/22/17 FOR PERMIT A LOW VOLTAGE OR LED STRIP DOOR JAMB SWITCH�S 20. IN ORDER TO INSURE REMOTE ACCESS TO THE LIGHTING CONTROL SYSTEM PROCESSOR(S),A PHONE OUTLET OR ETHERNET CONNECTION,AS WELL AS AN ELECTRICAL FO FIBEROPTIC ILLUMINATOR nI KEYPAD OUTLET IS REQUIRED AT ALL PROCESSOR LOCATIONS. 21. ELECTRIAL DEVICES, HOR AND AN CONTRACTORAREI VERIFYWITALL FINISHES OF L-000 STANDARD LEGENDS & NOTES RECESSED LINEAR LIGHT LINE VOLTAGE CONTROL SYSTEM DIMMER ELECTRICAL DEVICES, LIGHTING TRIMS,AND WALL-BOX DEVICES WITH THE INTERIOR DESIGNER AND/OR OWNERS PRIOR TO ORDERING. IF THESE COLORS OR FINISHES ARE NOT RF TABLETOP KEYPAD VERIFIED, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT AND L-1 OO LIGHTING PLAN 1 I RECESSED LINEAR WALL WASH DEVICES AT NO COST TO THE OWNERS. RF LAMP DIMMER-PLUG INTO HOT OUTLET 22. ELECTRICAL CONTRACTOR TO PROVIDE(10)EXTRA OF 10 DEGREE SPOTS,25 DEGREE DATE: 02/22/2017 48" 0 1 SURFACE-MOUNTED LINEAR LIGHT NARROW FLOODS,40 DEGREE FLOODS,AND 60 DEGREE WIDE FLOODS FOR AIMING AND GD CIRCUIT NUMBER SPARE STOCK FOR OWNER. PROVIDE FLOOD BEAMSPREADS FOR MR-16 LAMPS WHERE SCALE: AS NOTED WALL-RECESSED STEP LIGHT BEAMSPREAD IS NOT DESIGNATED ON 186 BEAMSPREAD DRAWINGS. ELECTRICAL • • CONTRACTOR TO REQUEST BEAMSPOREAD PLAN FROM 186 PRIOR TO PURCHASE AND JOB #: 16-27 ELECTRICAL TRIM OUT OF MR16 LAMPHOLDERS. e IN-GROUND WELL LIGHT V TELEPHONE 23.ALL ADJUSTABLE ACCENTS TO BE AIMED STRAIGHT DOWN AT ELECTRICAL TRIM-OUT. DRW BY: VK El E POST TOP LIGHT V DATA OUTLET ELECTRICAL CONTRACTOR TO PROVIDE LADDERS AND PERSONNEL TO ASSIST 186 AND CLIENT WITH FINAL AIMING OF ADJUSTABLE FIXTURES WHEN ARTWORK AND FURNITURE ARE CHK BY: VK IN PLACE. AIMING SESSIONS ARE TYPICALLY AFTER SUNSET. LANDSCAPE ACCENT v CABLE TELEVISION OUTLET SEAL & SIGNATURE: 24. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR APPROPRIATE SIZING OF ALL ELECTRICAL CONDUCTORS. 12-VOLT SYSTEMS SUCH AS MONORAIL,CABLE,AND LOW VOLT �-. Arvl SATELLITE TELEVISION OUTLET EXTERIOR PATH LIGHT TRACK SHALL BE FED WITH STRANDED WIRE OF AN APPROPRIATE GAUGE FOR LIGHTING LOAD SHOWN ON PLANS.WIRING SHALL BE SIZED SUCH THAT VOLTAGE DROP TO LOW POOL LIGHT IT srnrl THERMOSTAT VOLTAGE SYSTEMS IS NOT GREATER THAN 10%. IF NECESSARY, USE MULTI-TAP TRANSFORMER TO ACHIEVE REQUIRED VOLTAGE AT EACH LIGHT. j UNDERWATER ACCENT XFMR TRANSFORMER ALL REFERENCES TO ELECTRICAL OR LOW VOLTAGE SYSTEMS THAT ARE NOT DIRECTLY RELATED TO LIGHTING ARE ON THE PLANS FOR REFERENCE ONLY.ACTUAL FINAL LOCATIONS AN TOUCHSCREEN AND DIMENSIONS ARE TO BE PROVIDED BY OTHERS. 1-HEADED RECESSED MULTIPLE ® SPEAKER STANDARD LEGENDS & NOTES 2-HEADED RECESSED MULTIPLE 3-HEADED RECESSED MULTIPLE �' 9 / ORM KOEUPN MIRRORI WITH NTEGRAL SWITCH N O SCALE VIF VERIFY IN FIELD TITLE: LEGENDS & NOTES SHEET: L-000 21 OF 22