Loading...
HomeMy WebLinkAboutB17-0027_M-000.pdf No °Fk4 z of D SIGN CO\D 1 T I O\S D ,CT,0„,01R3C G \D PIPING L G \D RAL L G \D F 4\ 4,551 VIA 110\5 03/29/17 WINTER OUTDOOR DESIGN TEMPERATURE -20°F SINGLE LINE DESCRIPTION DOUBLE LINE >< OR - - GATE VALVE GO CARBON MONOXIDE SENSOR AAV AIR ADMITTANCE VALVE (STUDOR OR EQUAL) —Ii— OR CHECK VALVE G2 CARBON DIOXIDE SENSOR AFF ABOVE FINISHED FLOOR ELEVATION 8,150 FEET 90° ELBOW DOWN -a OR f BALL VALVE O HUMIDISTAT ABV ABOVE ELECTRICAL POWER AVAILABLE 1220/1,08/1, 90° ELBOW UP f BUTTERFLY VALVE OD DEHUMIDISTAT BLW BELOW 08/3 -K OR ter— PLUG VALVE 0 NITROGEN DIOXIDE SENSOR CFM CUBIC FEET PER MINUTE (AIR QUANTITY) APPLICABLE CODES 2015 IBC \ > \ OFFSET TO CHANGE ELEVATION GPM CIRCUIT SETTER WITH GPM OS J CAT 30° WHEN POSSIBLE. EffD � OCCUPANY SENSOR (RE: ELECTRICAL) CLG CEILING 2015 IMC ARROW SLOPES DN. ) 2015 IPC �� GLOBE VALVE PB ERV PUSH BUTTON CONTROLLER (LIGHTED) CO CLEANOUT 2015 IFGC ' I �% OR STRAINER (Y-TYPE) WITH BLOW-DOWN PT ERV PERCENT TIMER CONTROLLER (LIGHTED) GONG CONCRETE ROUND RADIUS ELBOW UN IT 9203 • OR —A— TWO-WAY AUTOMATIC CONTROL VALVE O SENSOR COTG CLEAN-OUT TO GRADE is OR THREE-WAY AUTOMATIC DIVERTING VALVE SM SNOWMELT SENSOR (TEKMAR 091/094) DN DOWN 90° STRAIGHT TEE EWE OR _:4_ SOLENOID VALVE e STATIC PRESSURE SENSOR DMPR DAMPER R EMO D E L \ rii OR PRESSURE REGULATOR (OR REDUCING VALVE) T O THERMOSTAT EA EACH 1 90 CONICAL TEE UNIT 9203 SHEET DESCRIPTION PAGE ��� TWO-WAY MODULATING CONTROL VALVE WALL ON/OFF CONTROL SWITCH EC ELECTRICAL CONTRACTOR .� © THREE-WAY MODULATING MIXING VALVE $T WALL TIMER SWITCH ER / EG EXHAUST REGISTER / EXHAUST GRILLE FOUR SEASONS M-000 MECHANICAL COVER SHEET 10 / 45° BRANCH RESORT & RESIDENCES M-100 MECHANICAL SCHEDULES 11 ENE 0 �� THERMOSTATIC MIXING VALVE (TMV) $V VARIABLE SPEED CONTROL ETR EXISTING TO REMAIN M-209D UNIT 9203 MECHANICAL PLAN (DEMO) 12 / I� DP DIFFERENTIAL PRESSURE VALVE EXEXHAUST VAIL, CO 45° CONICAL TEE . • M-209P UNIT 9203 MECHANICAL PLAN (PROPOSED) 13 EMI S41- OR S PRESSURE RELIEF VALVE All l ID \ / I C: FCC FLOOR GLEAN-OUT u CLIENT: T MANUAL AIR VENT FD FIRE DAMPER OR FLOOR DRAIN Tim & Nancy Buese P-209D UNIT 9203 PIPING PLAN (DEMO) 14 SIZE OR SHAPE TRANSITION � � f 110\ = Unit 9203 P-209P UNIT 9203 PIPING PLAN (PROPOSED) 15 AUTOMATIC AIR VENT FPC FIRE PROTECTION CONTRACTOR FOUR SEASONS VAIL M-300 MECHANICAL SCHEMATICS 16 � )) 4 VACUUM BREAKER GPM GALLONS PER MINUTE (WATER FLOW RATE) 1 Vail Road ROUND FLEXIBLE DUCT : n VAIL, CO 81657 60-- OR PRESSURE GAUGE WITH GAUGE COCK SIZE (INCHES) LD SUPPLY DIFFUSER (LINEAR) M-400 MECHANICAL SPECIFICATIONS 4 11 ARCHITECT: SEQUENCE OF OPERATION P NOTE: FOR STANDARD MODULE SIZE \ / I PRESSURE SENSOR MC MECHANICAL CONTRACTOR Creative Design Associates X 90° ELBOW DOWN j x REGISTERS, SIZE GIVEN IS NECK g 'I` PRESSURE / TEMPERATURE TEST PORT SIZE. REFER TO AIR DEVICE SCHEDULE MOD MOTOR OPERATED DAMPER 434 BROADWAY, 5TH FLOOR • SHEET FOR MODULE SIZE. NEW YORK, NY 10013 I 90° ELBOW UP T TEMPERATURE SENSOR OA (OR OSA) OUTSIDE AIR t. 212-748-8900 11 m * = AIR QUANTITY (CFM) WESTERN US THERMOMETER WELL CA - COMB. AIR OED OPEN END DUCT 4700 E BROMLEY LN, SUITE 105 DROP/ RISE DROP/ RISE OA - OUTSIDE AIR BRIGHTON, CO 80601 OFFSET TO CHANGE ELEVATION (AT 30° D THERMOMETER 12/6 CD-1 250 RA - RETURN AIR PC PLUMBING CONTRACTOR J l I > ] WHERE POSSIBLE). ARROW IN DIRECTION EA - EXHAUST AIR t. 646-747-2171 J OF AIRFLOW. INDICATE DROP OR RISE. BTU METER (FLOW 4 TEMPERATURE DIFFERENCE) I MA - MIXED AIR PR PIPE RISER c. 917-756-0057 MUA - MAKE-UP AIR dsorenson@ralcompanies.com ROUND RADIUS ELBOW Q FLOW METER TYPE OF AIR DEVICE. Design RA (OR R/A) RETURN AIR DE Fs FLOW SWITCH RE: SCHEDULE SHEET RR RETURN REGISTER Duet INTERIOR Group, LLC • RECTANGULAR ELBOW WITH mu4 AQUASTAT RG (RAG) RETURN AIR GRILLE 901 ACOMA SUITE 200 TURNING VANES DENVER, CO 80204 ti —1>0004— OR w BRAIDED TYPE FLEXIBLE PIPE CONNECTOR I SA (OR S/A) SUPPLY AIR — t. 303-783-9327 miranda@duetdesigngroup.com J WITH l SQBRANCH UARE ELBOW-�FF 1M&nim v-- ELASTOMERIC PIPING ISOLATOR (WITH KEVLAR) S. DMPR SMOKE DAMPER SPLITTER DAMPER —I I I— PIPE UNION 1 GNA I SR SUPPLY REGISTER (SIDEWALL OR DUCT MOUNTED) MECH/PLUMBING ENGINEER: Rader Engineering J SPLIT BRANCH TAKE-OFF II QUICK CONNECT (GAS) OR HOSE BIB (WATER) SV STUDOR VENT (SIZED BY CONTRACTOR) PO BOX 8610 WITH RADIUS ELBOW 4 DUCTING: PIPING: AVON, CO 80620 SPLITTER DAMPER ORice\ RADIANT OR SNOWMELT MANIFOLD WITH ACCESS TYP TYPICAL t. 970-845-7910 OA - OUTSIDE AIR CW - CHILLED WATER EA - EXHAUST AIR DW - DOMESTIC WATER TRANS TRANSITION BryanH@raderengineering.com JBRANCH TAKE-OFF WITH 0 PIPE UP OR PIPE UP 4 DOWN HW - HEATING WATER RADIUS HEEL AND DAMPER GENERAL: G - GAS OR 0 PIPE DOWN T/A THROW AWAY ELECTRICAL ENGINEER: US - UTILITY SHAFT R - REFRIGERANT C3S Incorporated BRANCH TAKE-OFF WITH AIR EXTRACTOR O FLOOR DRAIN FLOOR SINK SSM -D - STORM DRAIN UNO UNLESS NOTED OTHERWISE 3212 WEST 45TH AVENUE — LT OD - OVERFLOWDRAIN US UTILITY SHAFT DENVER, CO 80211 . OA Wv - WASTE 4 VENT t. 303-480-5144 LINED DUCTWORK —II HORIZONTAL CLEANOUT W RISER NUMBER VTR VENT THROUGH ROOF Theresa@c3sengineeringinc.com (UNLESS NOTED OTHERWISE) Q❑ OR 0 FLOOR CLEAN-OUT W/ WITH LIGHTING DESIGN: ' 186 Lighting Design Group, Inc. SQUARE NECK CEILING DIFFUSER O METER WCO WALL CLEAN-OUT 1200 BANNOCK STREET \ 4-WAYNTHROW LE SD INIRECTIONAL DICATED OTHERWISE XFER TRANSFER AI � _ ' � f\A �\ 1 DENVER, CO 80204 PIPING D S f G\A 10\5 Vt. 303-534-5350 O ROUND NECK CEILING DIFFUSER 0 11 D - I I �\ I 1 I IONS gmackell@186group.com 4-WAY DIRECTIOONAL THROW UNLESS INDICATED OTHERWISE CWS/R CHILLED WATER SUPPLY/RETURN KITCHEN DESIGN: SIDEWALL SUPPY GRILLE 'r CS/R CONDENSER WATER SUPPLY/RETURN exquisite kitchen design T OR REGISTER WITH . 1NWS/R HEATING WATER SUPPLY/RETURN TERMINAL TYPE: AHU AIR HANDLING UNIT 601 SOUTH BROADWAY SUITE F I I AIR EXTRACTOR HWS/R(HT) HEATING WATER SUPPLY/RETURN HIGH TEMP CV - CONSTANT VOLUME BOX (SERIES) DENVER, CO 80209 FP - FAN POWERED BOX (PARALLEL) AS AIR SEPARATOR 303-282-0382 HWS/R(LT) HEATING WATER SUPPLY/RETURN LOW TEMP .410"IVV - VARIABLE VOLUME VR - VARIABLE VOLUME w/ REHEAT STATIC PRESSURE CLASS SMS/R RS 4 RL SNOWMELT SUPPLY/RETURN B BOILER (HOT WATER) mikalo@myekdesign.com ORTUSR COLUMN)RECLASS CHANGE .4IH (INCHES CREFRIGERANT SUCTION 4 REF. LIQUID -- DGw-- -- DOMESTIC COLD WATER (DCW) COOLING AIR QUANTITY (CFM) CHFP 100 CHILLER ISSUE DATE COMMENT -- " SUPPLY DUCT RISER " __ DHW -- DOMESTIC HOT WATER (DI-1W) C10/ 540 MINIMUM AIR QUANTITY (CFM) FOR GC COILING COIL DHR DOMESTIC HOT WATER RECIRC (DHR) VENTILATION OR HEATING. 1 2/22/17 FOR PERMIT -- DHW-T -- DOMESTIC HOT WATER (TEMPERED) GH CABINET HEALER PRIMARY AIR VALVE SIZE RETURN, EXHAUST OR W WASTE CT COOLING TOWER CELL OUTSIDE AIR DUCT RISER — — — — —V— — — — — VENT GW GREASE WASTE CV CONSTANT VOLUME BOX PW PRESSURIZED WASTE CEILING RETURN AIR . 1,-- IW INDIRECT WASTE DEF DISHWASHER EXHAUST FAN --1- . GRILLE OR REGISTER \ BD BUILDING DRAIN MOD L L G ND EBH ELECTRIC BASEBOARD HEATER 4 BS BUILDING SEWER DOOR GRILLE SD STORM DRAIN ECU EVAPORATIVE COOLING UNIT OD OVERFLOW DRAIN (STORM) 69 POINT OF DISCONNECTION DATE: 2/22/17 EF EXHAUST FAN SOD SEDIMENT 4 OIL DRAIN 8 POINT OF NEW CONNECTION SCALE: N/A MANUAL BALANCING DAMPER _ G NATURAL GAS (A) ABANDON ERV ENERGY RECOVERY VENTILATOR (AIR TO AIR HX) MPG MEDIUM PRESSURE NATURAL GAS ET EXPANSION TANK JOB #: 17006.00 • • LPG PROPANE GAS (D) DEMO 4. MOTORIZED DAMPER 0111 D DRAIN (E) EXISTING FC FAN COIL _ DRW BY: BJH CD CONDENSATE DRAIN FP FAN POWERED BOX F FIRE SPRINKLER (F) FUTURE CHK BY: JDR CA COMPRESSED AIR (N) NEW GF GLYCOL FEEDER SMOKE DAMPER GEO GEOEXCHANGE SOURCE SEAL 8. SIGNATURE: SWS/R SOLAR WATER SUPPLY/RETURN (R) RELOCATE HC HEATING COIL (E) EXISTING HP HEAT PUMP _�`��,� ��', FIRE DAMPER111* (UG) UNDERGROUND HX HEAT EXCHANGER 2p�p.00 1-;0 �1'1 % ® COMBINATION FIRE AND SMOKE DAMPER - IyC7� } NO ` fi + H HUMIDIFIER . s'.(2.. L :O `I I F/S F/S KEF KITCHEN EXHAUST FAN 4 po 3/g 2/1���, 00 INLINE WET ROTOR PUMP MV MIXING VALVE ��1 9 `: .•�v CEILING RADIATION DAMPER t♦_ [®1 INLINE WET ROTOR PUMP (W/ INTEGRAL CHECK) 6 ❑ •, r .. k P PUMP (SEE PIPING LEGEND FOR DETAILS) 4�I)�fi •"`�.10,�+! INLINE CLOSE-COUPLED PUMP 1�'��vA~� GRAVITY BAGKDRAFT DAMPER RF RETURN/RELIEF AIR FAN SF SUPPLY FAN BASE MOUNTED END SUCTION PUMP TEF TOILET EXHAUST FAN 0 _A_ TITLE: DUCT MOUNTED SMOKE DETECTOR O TMV THERMOSTATIC MIXING VALVE MECHANICAL \ / CEILING ACCESS PANEL \ / UH UNIT HEATER COVER SHEET v v VV VARIABLE VOLUME BOX _1 y WALL CAP - BATH OR DRYER EXHAUST y VR VARIABLE VOLUME BOX W/ REHEAT SHEET: WITH INTEGRAL BACKDRAFT DAMPER11 AA-000 WH WATER HEATER10 OF 22