A14-0046_A14-0046 cut sheet_1409064180.pdf
VICO SIMPLEXGRINNELL 6240 Smith Road SimplexGrinnell Denver, Colorado 80216 www.simplexgrinnell.corn Tele: (303) 355-0500 Fax: (303) 355-0615 Fire Alarm Product Data Submittal for: Lodge At Vail Unit 516 Remodel 174 Gore Creek Drive Vail, CO 81657 Prepared for: Encore Electric 77 Metcalf Road Avon, CO 81620 tqco SimplexGrinnell 6240 Smith Road Denver, Colorado 80401 Sales: (303) 355-0500 Service: (303) 355-0500 Fax: (303) 355-0615 PROJECT: Lodge At Vail Unit 516 Remodel PREPARED FOR: Encore Electric TYPE: DESCRIPTION: 4098-9714 PHOTO SENSOR 4098-9794 SENSOR BASE W/SOUNDER 4090-9001 SUPERVISED IAM C01224T SYSTEM SENSOR CO SENSOR 4902-9717 SPEAKER WHITE TRUEALERT B®Simplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Sounder Base 4098-9794 for use with MEA (NYC) Acceptance* TrueAlarm Photoelectric and Heat Sensors Features Modular TrueAlarm sensor base with built-in electronic alarm sounder: • Piezoelectric sounder provides high output(88 dBA) with low current requirements(20 mA) All II 1 IIL • For use with interchangeable TrueAlarm photoelectric or heat sensors(ordered separately) - - — - Sounder operation details: TrueAlarm Photoelectric Sensor Mounted in • Powered from 24 VDC or from a compatible Sounder Base 4098-9794 Notification Appliance Circuit(NAC) • Synchronized via communications or by the NAC,if TrueAlarm Analog Sensing Description NAC powered** • Sounder can be manually activated from the control panel Sounder bases combine an audible notification appliance • Sensor and sounder operation is listed to UL Standard 268 and a TrueAlarm analog sensor to provide: • Sounder operation is also listed to UL Standard 464 Digital Communication of Analog Sensing. as an audible notification appliance Sensors provide an analog measurement that is digitally TrueAlarm analog sensing operation: communicated to the control panel where it is analyzed • Analog sensor information is digitally communicated and an average value is determined and stored.An alarm to the control panel via IDNet or MAPNET II or other abnormal condition is determined by comparing two-wire communications the sensor's present value against its average value. • Sensor information is processed by the control panel Intelligent Data Evaluation.Monitoring each sensor's to determine sensor status average value provides a software filtering averaging For use with the following Simplex®products: process that compensates for environmental factors(dust, • 4100ES,4010ES,4010,and 4100U Series control dirt,etc.)and component aging,providing an accurate panels;and 4008 Series control panels with reduced reference for evaluating new activity. The result is a feature set(refer to data sheet S4008-0001 for details) significant reduction in the probability of false or • 4020,4100,and 4120 Series control panels,and nuisance alarms caused by shifts in sensitivity,either up Universal Transponders equipped for MAPNET II or down. operation Control Panel Selection.Peak activity per sensor is General features: stored to assist in evaluating specific locations.The alarm • Louvered smoke sensor design enhances smoke set point for each TrueAlarm sensor is determined at the capture by directing flow to chamber;entrance areas control panel,selectable as more or less sensitive as the are minimally visible when ceiling mounted individual application requires. • Designed for EMI compatibility • Magnetic test feature is provided Timed/Multi-Stage Selection.Alarm set points can be • Optional accessories include remote LED alarm programmed for timed automatic sensitivity selection indicator and output relays (such as more sensitive at night,less sensitive during day).Control panel programming can also provide Additional base reference: multi-stage operation per sensor.For example,a 0.2% • For standard bases,refer to data sheet 54098-0019 level may cause a warning to prompt investigation while a • For isolator bases,refer to data sheet S4098-0025 2.5%level may initiate an alarm. • For photo/heat sensors,refer to data sheet 54098-0024 Sensor Alarm and Trouble LED Indication.Each (single address)and 54098-0033 (dual address) sensor base's LED pulses to indicate communications with the panel.If the control panel determines that a • llis produa hes bean approved bytheCdifariaStateFireNershal(CSFM)pusuanttoSedben sensor is in alarm,or that it is dirty or has some other type 13144.1 d the CdifcniaHeathadSafetyCode.Sae CSFM Listirx�7300-0026217and of trouble,the details are annunciated at the control panel flo7271-W26231 t.a tdf allowable atyd vak uss and/or fions D rtmp,tdB,adn M a35-etial s this and that sensor base's LED will be turned on steadily. listings may beappicable contact your local Snplecproduct supplier for the latest status.Listings During a system alarm,the control panel will control the axl apprualsuxlerSimplex The ReoordaCo.are the propertydTyco Fire Protection LEDs such that an LED indicating a trouble will return to ''Totalquarityofsarderbasesavailableforcedingonthesarecormuticatiascharnelrayvay pulsing to help identify the alarmed sensors. Alth panel application aidavailabilitydt pater.tomer tospecific co*dpanel requirements. S4098-0028-9 6/2014 Additional Sounder Base Features Mountin• Reference Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type change.Access is from the Electrical Box Requirements:(boxes are by others) front under the removable sensor. Without relay:4"octagonal or 4"square,1-1/2"deep;single gang, 2"deep Automatic sensor type identification provides With relay:4"octagonal or 4"square,1-1/2"deep,with 1-1/2" default sensitivity when substituting sensor types. extension ring Different sensor types can be easily interchanged to meet 4"(102 mm)Square Box 4"(102 mm)Octagonal Box specific location requirements.This feature also allows Surface mount reference intentional sensor substitution during building I L 1_ construction.When conditions are temporarily dusty, Cinstead of covering the smoke sensors(causing them to be 1-1/2"(38 mm) C1- " box depths disabled),heat sensors may be installed without reprogramming the control panel. 4 Flush mount reference,mount even with final Integral red LED indicates power-on by pulsing,or surface,or with up to 1/4"(6.4 mm)maximum recess alarm or trouble when steady on.The exact status is annunciated at the fire alarm control panel. 1 • - �/J Optional 4098-9822 Relay Fire alarm control panel provides: (Mounts in base electrical box Not• Peak value logging allowing accurate analysis of each adapterpSinglelatgang andolrequires o esional plate(RACO volume,see notes below) sensor for individual sensitivity selection No.787 or equal)is / • Sensitivity monitoring satisfying NFPA 72 sensitivity required when using 4" _ square box(by others) t \\\$ testing requirements;automatic individual sensor Relay size. check verifies sensor integrity . 2-1/2"X 1-1/2"X 1" �oL� (64 mm X 38 mm X • Automatic environmental compensation,multi-stage J 25.4 mm),3.75 cubic inches alarm operation,and display of sensitivity directly in percent per foot 6-3/8"Dia. 4098-9832 Adapter Plate,required for mounting x 1/4"thick • Ability to display and print detailed sensor to surface mounted boxes(mounts inverted) information in plain English language 1. 6-7/16"(164 mm) N Accessories 1-1/8" 4098-9822, LED Annunciation Relay activates when (29 mm\ base LED is on steady,indicating a local alarm or trouble. Contacts are DPDT,rated 2 A @ 30 VDC; 1/2 A @ 120 VAC for transient suppressed loads(requires external LED status Sound output louvers 24 VDC coil power). indicator extend from front to side 2098-9808, Remote red LED Alarm Indicator mounts on UM a single gang box to provide status indications where the sensor location may not be readily visible. (Photoelectric sensor shown for reference) NOTES: 1. Review actual wire size,wire count,box type,and whether 4098-9822 relay is used before determining box size. ALARM 2. Mounting to flush mounted box also fits single gang handy box, 0 2-1/8"(51 mm)deep if wiring allows.(Not applicable if 4098-9822 relay is used.) 3. For surface mounted boxes,use 4"square box with single gang adapter plate(RACO No.787 or equal,by others)or 4"octagonal 0Simplex box,both require 4098-9832 Adapter Plate. 4. When 4098-9822 relay is used,mount relay in electrical box and use 1-1/2"extension ring(by others)on 4"square or octagonal box of 1-1/2"or 2-1/8"depth as required. 5.Refer to Installation Instructions 574-707 for additional information. 2098-9808 Remote LED Alarm Indicator 2 S4098-0028-9 6/2014 TrueAlarm Analog Sensor Features 4098-9733 Heat Sensor Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Electronics are EMI/RFI shielded compensated,fixed temperature sensing,selectable with or without rate-of-rise temperature sensing.Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the Fixed Temp. UL&ULC FM Spacing,Either Fixed control panel for either 15°F(8.3°C)or 20°F(11.1°C) Setting Spacing Temperature Setting per minute.Fixed temperature sensing is independent of 135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed rate-of-rise sensing and programmable to operate at (57.2°C) (18.3 m) temperature only;RTI=Quick 135°F(57.2°C)or 155°F(68°C).In a slow developing 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-rise (68°C) (12.2 m) selection;RTI=Ultra Fast operate the rate-of-rise feature.However,an alarm will be initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range • Built-in insect screens from 32°F to 155°F(0°C to 68°C).This feature can provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availability. 4098-9714 Photoelectric Sensor 6-7/16°(164 mm) .� TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available 2-9/16" ' for each individual sensor,ranging from 0.2%to 3.7%per (65 mm) foot of smoke obscuration. Sensitivities of 0.2%,0.5%, II■I. and 1%are for special applications in clean areas. Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and 3.7%.Application type and sensitivity are selected and then monitored at the fire alarm control panel.* 4098-9733 Heat Sensor with 4098-9794 Sounder Base The sensor head design provides 360°smoke entry for optimum smoke response.Due to its photoelectric WARNING: In most fires, hazardous levels of smoke operation,air velocity is not normally a factor,except for and toxic gas can build up before a heat detection impact on area smoke flow. device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly 6-7/16"(164 mm) recommended. A Application Reference Sensor locations should be determined after careful 2-5/16" ' consideration of the physical layout and contents of the (58 mm) M61•�IF MI 1M area to be protected.Refer to NFPA 72,the National Fire Nin1. I Alarm and Signaling Code.On smooth ceilings,smoke sensor spacing of 30 ft(9.1 m)may be used as a guide. For detailed application information,refer to 4098 4098-9714 Photoelectric Sensor with Sounder Base Detectors, Sensors, and Bases Application Manual,Part Number 574-709.* *For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0028-9 6/2014 TrueAlarm Analo• Sensin• Product Selection Chart TrueAlarm Sounder Base* Model Description Compatibility Mounting Requirements Sounder Base with connections Sensors:4098-9714 and 4098-9733 4098-9794 for Remote LED Alarm Indicator Refer to page 2,mounting reference or Unsupervised Relay Options:2098-9808 remote LED alarm indicator or 4098-9822 relay TrueAlarm Sensors (ordered separately) Model Description Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Refer to page 2,mounting reference 4098-9733 Heat Sensor Sounder Base Accessories (ordered separately if required) Model Description Mounting Requirements 4098-9832 Adapter Plate,required for surface mounted 4"electrical boxes Refer to page 2,mounting reference 2098-9808 Remote red LED Alarm Indicator on single gang Single gang box, 1-1/2"minimum depth Choose one if stainless steel plate required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2" 4098-9822 mounted only in base electrical box) extension on 4"square or octagonal box) Refer to data sheet S4098-0019 for other compatible bases. Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. S•ecifications General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications,auto-selected, 1 address per base Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2) Current 1 mA typical supplied from communications,no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Temperature Range 32°F to 100°F(0°C to 38°C) Operating With 4098-9733 32°F to 122° F(0°C to 50°C) Temperature Range With 4098-9714 15°F to 122° F(-9°C to 50°C) Storage Temperature Range 0°F to 140°F(-18°C to 60°C) Humidity Range 10 to 95%RH Smoke Sensor 4098-9714, Air velocity is 0-4000 ft/min(0-1220 m/min) Ambient Ratings Photoelectric Sensor Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(Sounder On) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Sounder Output Appliances and UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel (Selectable) Unsupervised Select when connected to NAC for sounder power, NAC provides supervision NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized pattern(Temporal or March Time,etc.)controlled by the NAC 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings,DPDT contacts for Power limited rating:2 A @ 30 VDC resistive/suppressed loads Non-power limited rating: 1/2 A @ 120 VAC Relay Operation Tracks base LED status,relay is on with trouble or alarm at the base TYCO,SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association(NFPA). SoS i m p I Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4098-0028-9 6/2014 www.simplex-fire.com CO 2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. aSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM and MAPNET II° Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (IAMs) Features IDNet or MAPNET II addressable communications supply both data and power over a single wire pair SimPl SIMPLEX TIME RECORDER i to provide": 4090-90010 SUPERVISED UN • Supervised Class B monitoring of normally open,dry INST.INSTR,511-331 DATE C contacts OD= ONEi INS 4 V I +IDNEi IN • Total wiring distance from IAM to supervision / resistor(s)of up to 500 ft(152 m) 9 p o 0 0 • Monitored connection is compatible with Simplex® v' 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised IAM • For use in indoor locations up to 158°F(70°C)such as (shown approximately 3/4 size) attic spaces or similar applications For use with following Simplex control panels: • Model Series 4008,4010,4010ES,4100U and 4100ES fire alarm control panels for IDNet communications • Model Series 4100/4100U/4100ES,4120,4020,and t_ 2120 Communicating Device Transponders(CDTs) equipped with MAPNET II communications Model 4090-9001: • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box PSr,oI evoE NO. • Screw terminals for wiring connections NO • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be 4090-9051 Supervised IAM viewed after installation(requires mounting bracket, (shown approximately 3/4 size) ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high Description humidity(LED is not present on this model) • Color coded 18 AWG leads for wiring Individual addressable modules (IAMs)receive IDNet communications provides current limited both power and communications from a two-wire monitoring: MAPNET II or IDNet circuit.They provide location • Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating device(such and waterflow switch(alarm)on same circuit using as single station smoke detector alarm contacts or heat detector contacts)or multiple devices at the same location one point by monitoring normally open dry contacts and the wiring • Available with IDNet communications only to an end-of-line resistor. Multiple operation modes are available and are selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic • Contact closure status can be tracked housing and provides screw terminal connections and a status indicating LED. • Momentary contact closure conditions can be selected at the panel to be latched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads.It does not provide a status indicating LED. UL listed to Standard 864 • These products have been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35-93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4090-0001-10 O•eration Current Limited Operation Applications Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only,these initiates an alarm or other response as programmed at the IAMB can provide quad-state sensing of normal,open fire alarm control panel. An open in the monitored circuit circuit, short circuit,and current limited conditions. wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line Panel Selections. Selections can be made at the control and current limiting resistors, dual functions such as panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable device contacts are momentary, such as from a rate-of-rise heat detector,or to track the device contact point. status(not available with the 2120 CDT). IAM Product Selection Model Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals;see applicable options below 4090-9051 Supervised IAM,encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws;galvanized steel 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kS2, 1/2 W; Standard end-of-line resistor harness for N.O.contact supervision 4081-9003 733-896 4.7 kS2, 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 k4, 1/2 W S•ecifications Electrical Power and Communications MAPNET II or IDNet,auto selected, 1 address per IAM Input Requirements Normally open,dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections (0.82 mm2 to 2.08 mm2) 4090-9051 Color coded wire leads, 18 AWG(0.82 mm2),8"long(203 mm) Installation Instructions 574-331 for 4090-9001; 579-572 for 4090-9151 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances 500 ft(152 m)maximum without protectors Distance from IAM to Contacts 400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Mechanical 4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm) Dimensions 4090-9051 1-9/16"W x 1-9/16"H x 9/16" D(40 mm x 40 mm x 14 mm) Housing Material,4090-9001 Black thermoplastic Encapsulation Material,4090-9051 Epoxy, beige Temperature Range 32°to 158° F(0°to 70°C); intended for indoor operation Humidity Range Up to 93% RH at 100° F(38°C) 2 S4090-0001-10 Mounting Information ® ®1 `� ,iwiring 4090-9001 IDNet ��_ ��; Field shown supervised IAM Mill l for reference _______________________ , ___. .. ..,,- _l_Ili lir,' 7.7mil 0 I ' 0 ; aarECOE. 1si I LED viewing port nem az ud, OH .. ._ ,.� e .- Single gang electrical �`t. O box 2-1/2"(64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws,for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate A r, H A O Light pipe for i or ®� LED viewing �0 4-1/4" 4-1/2" (108 mm) (114 mm) DISCONNECT POWER DISCONNECT POWER BEFORE SERVICING BEFORE SERVICING © © \— 0 i V \ / V 2-1/2" 2-13/16" (64 mm) (72 mm) 4090-9806,Trim plate for 4090-9807,Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-10 4090-9051 Mounting Information Address setting is at rear of housing 4090-9051 Encapsulated Supervised IAM A, pl. MiaI -1 owsw.,; ® Single gang electrical box 2-1/2"(64mm) minimum depth (supplied by others) 0,0 Single gang blank cover plate and mounting screws (supplied by others) Tyco is a registered trademark of Tyco International Services GmbH and is used under license.Simplex,the Simplex logo,IDNet,and MAPNET II are trademarks of Tyco International Ltd.and its affiliates and are used under license. B3S i m p 1 EX SimplexGrinnell LP Westminster• Westminster,MA•01441-0001•USA S4090-0001-10 ® www.simplexgrinnell.com ©2011 Tyco.All rights reserved.All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. SYSTEM �$ SENSOR° C01224T and C01224TR • • • mull Carbon Monoxide Detectors with RealTest°Technology *. . The System Sensor C01224T and C01224TR(round) ..#. Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features With RealTest®technology,the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a • RealTest®enables a functional test using canned CO CO gas agent,fully meeting the requirements of NFPA 720:2009. • Full compliance with UL 2075 Simply put the detector into RealTest mode,spray a small amount • A code-required trouble relay of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating successful gas entry.(See • Wiring supervision with SEMS terminals the reverse page or the user manual for complete instructions.) • A six-year end-of-life timer • 12/24 VDC When dangerous amounts of CO are detected,the CO1224T and A low current draw of 20 mA in standby and 40 mA in alarm CO1224TR detectors alert residents by sounding and flashing a • temp 4 signal alarm.With 24/7 central station monitoring, residents • Versatile mounting for wall and ceiling are guaranteed protection whether they are away from home, • Accurate and reliable electrochemical sensing technology sleeping,or already suffering from the effects of CO. • Optional CO-PLATE CO Detector Replacement Plate to upgrade The CO1224T and CO1224TR are designed for system operation. previously installed competitor detectors to the CO1224T These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision.With a low current draw,these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels.As 12/24 VDC detectors,the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. Agency Listings U :5rry4 L • s... LISTED 115 E307195 E304075 5276-1653:0194 C01224T and C01224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million(ppm),as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size:C01224T Length:5.1 in,Width: 3.3 in,Height: 1.3 in C01224TR Diameter:6 in,Height: 1.3 in Approximate Weight C01224T:7 oz;C01224TR: 11 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest®Feature: The System Sensor C01224T and C01224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. C Push and hold the Test/Hush button for Spray canned CO agent into Verify CO sensing at the two seconds to enter RealTest mode.The the detector. control panel.The detector will green LED will flash once every second automatically exit RealTest alarm to indicate RealTest mode has started. mode after about 20-60 seconds. NOTE:Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(except in RealTest mode). IMF Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel to indicate it is time to replace the detector.An electrochemical CO detector lifespan is about six years.The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when necessary)of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information CO PLATE Part No. Description C01224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest®Technology C01224TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTest®Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2012 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR® for current product information,including the latest version of this data sheet www.systemsensor.com scoso0loo•4/12 S®SimplEx Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; Audible Notification Appliances MEA (NYC) Acceptance* Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount Features - - Fire alarm speakers with models for ceiling or wall mount: • Four inch cone(102 mm)provides high quality tone and voice reproduction • Multi-tapped design provides output power of '/2, 1, a� . or 2 W with either 25 or 70.7 VRMS input • In/out wiring terminals for 18 AWG to 12 AWG • Mounts to 4"square outlet box, 1 '/2"deep with 1 ''/2" deep box extension • Capacitor input for connection to supervised notification c� appliance circuits FIRE • Rugged,high impact,flame retardant thermoplastic housings Rectangular Wall Mount Speakers are Available • UL listed to Standard 1480 as Red with White"Fire" Lettering and • ULC listed to Standard S541,refer to page 4 for White with Red "Fire" Lettering required minimum wattage tap per housing type / • Compliant with NFPA 72,520 Hz Low Frequency Signal Requirements for Sleeping Areas Rectangular housing models feature: „ • Appearance that complements TrueAlert strobes and speaker/strobes • Red or white housings with"FIRE"lettering for surface or semi-flush wall mount • Optional matching adapter skirts for covering surface mounted electrical boxes* • Optional red wire guard Round Speakers are Available in Off-White (no lettering) Round housing models feature: • Off-white color(no lettering)for flush mount on ceiling S•ecifications or wall • Compatible with optional tile bridge 2905-9946 Dimensions,Rectangular Wall Mount Housings Housing Dimensions 5'//"H x 5"W x 1 '/2"D Introduction (130 mm x 127 mm x 38 mm) Simplex®4902 Series speakers provide high quality sound Depth into Box 2 3/4"(70 mm) for emergency fire alarm use as well as for background Dimensions, Round Housings music.The moisture-repellent speaker is designed for D Housing Dimensions 7'/2'Diameter,'/2" smooth frequency response with minimal distortion. (191 mm x 13 mm) The multi-tapped speaker transformer accommodates Depth into Box 2'/4"(70 mm) either 25 or 70.7 VRMS and provides an output of from 1/4 General Specifications to 2 W to provide flexibility for satisfying the Input Voltage 25 or 70.7 VRMS requirements of the installed conditions. Power Taps '/4,'/2, 1,and 2 W Rectangular housing models are for surface or semi-flush Input Terminal Ratings 18 to 12 A2 WG 2 wall mount applications.Round housing models are (0.82 mm to 3.31 mm ) for ceilingapplications but can be wall mounted Fire Alarm 400 to 4000 Hz typically pp Frequency if desired.The rectangular housing speakers are designed Response General 125 to 12 kHz to compliment the TrueAlert family of strobes and Signaling speaker/strobes,providing conventional,non-addressable Sound Output See information on page 4 speaker operation. Temperature Range 32°to 100° F(0°to 38° C) • Refer to page 2 fa guard and adapter skirt listing. produd has been approved by the Humidity Range 10%to 95%RH from 32°to Califaria State Are Marshal(CSFM)pursuant to Section 13144.1 of the California Health 122° F(0°to 50° C) and Safety Code.See CSFM Listing 7320-0026:242 fa allowable values and/or wnditicns concerning material presented in this document.Additional listings may be applicable; contact your local Srrplex prodrxt sgpplier fa the latest status Listings and approvals aider Simplex Time Recorder Ca are the property of Tyco Are Protection Products. S4902-0003-7 5/2014 Product Selection Speakers Model* Description Dimensions 4902-9716(CA) Rectangular housing,wall mount Red with white"FIRE"lettering 5'/8" H x 5"W x 1 '/z"D 4902-9717(CA) speaker White with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4902-9721 (CA) Round housing speaker,ceiling or wall Off-white(no lettering) 7'/2"Diameter x'/2"D mount (191 mm x 13 mm) * ULC listed model are designated with a CA suffix(4902-9716CA). Refer to Installation Instructions 574-765 for non-suffix model numbers and to Installation Instructions 579-324 for CA suffix model numbers. Mounting Adapters Model Description Dimensions 4905-9941 Red Use to cover surface mounted 5%"H x 5'/4"W x 3 3/16"D Surface mount adapter skirt; 1-1/2"deep box with 1-1/2" (136 mm x 133 mm x 81 mm) (not ULC listed) deep extension external to Total surface depth with 4905-9942 White wall(see diagram on page 3) speaker=4%"(117 mm) 2905-9946 Tile bridge for 4902-9721 Speaker See diagram on page 3 4905-9931 Adapter Plate, red,for mounting to 2975-9145 box(typically for retrofit, 8 5/6"x 5 3/4"x 0.060"Thick may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red mounting box, requires Adapter Plate 4905-9931 7'/8'x 5'/8'x 2 3/4'D (200 mm x 130 mm x 70 mm) Covers and Guard Model Description Dimensions 4905-9988 Red speaker cover with white"FIRE"lettering Interchangeable with 5'/8" H x 5"W x 1 '/2"D 4905-9989 White speaker cover with red"FIRE"lettering TrueAlert horns (130 mm x 127 mm x 38 mm) Red wire guard with mounting plate; compatible with semi-flush or surface 6/s"H x 6/s"W x 3'/8"D 4905-9999 mounted boxes;for use with 4"square electrical box mounting hole (154 mm x 154 mm x 79 mm) patterns only(UL listed by Space Age Electronics Inc.) Wall Mount S•eakers, Installation Reference Mounting requires a 4"(102 mm)square box,1-1/2"(38 mm)deep,with a 4"box AMMIIIEEr/ extension,1-1/2"deep,by others iin - Speaker assembly 4 I O • ` O i I 7 o -) O I, ¢ 1R i� \Wiring input terminals and speaker tap I call ll I°ISI �r selection are accessible from rear of IIspeaker housing Transparent speaker housing Removable cover (tool required) 2 S4902-0003-7 5/2014 Round Speaker Installation Reference (typically ceiling mount, can be wall mounted) 4"square,1-1/2"deep box C with 1-1/2"extension(by others) � o Wiring input terminals and speaker ✓ �0 7tap selection are accessible from , eio C � 0 rear of speaker housing :(.,. ___\. ./ ((( ,„„.......„,( ) ) o ri Front View 2905-9946 Tile Brid•e Dimensions 0.024"thick sheet 3-3/4"(95 mm)square metal,folded with cutout,centered on plate 1/2" lip each side 1/2" (13 mm).- o 0 13-3/8" '. __________ (340 mm) 1/4"diameter(6 mm) holes,4 places 6-11/16" (170 mm) 23-11/16"(602 mm) '. Surface Mounted Speaker Reference (Adapter Skirts are Not ULC listed) 4"(102 mm)square box, 1-1/2"(38 mm)deep with conduit shown for reference 4"(102 mm)square box extension, 1-1/2"(38 mm)deep III I-�_ Optional 4905-9999 Wire Guard—1 ii■ r i•�IIM --II Speaker II assembly 1 El L_ Surface mount adapter skirt,3-3/16"deep: 4905-9941,Red;4905-9942,White Conduit knockouts are provided on all four sides Wall surface 3 S4902-0003-7 5/2014 Speaker Sound Output Specifications Sound Output Ratings @ 10 ft(-3 m)per UL 1480 Reverberant Chamber Testing Model Type Input Voltage Selected Tap 1/4W 1/2W 1 W 2W 4902-9716 25 VRMS 80 dBA 83 dBA 85 dBA 88 dBA 4902-9717 Rectangular Housing 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA 4902-9721 Round Housing 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA Sound Output Ratings @ 3 m (-10 ft)per ULC S541 Anechoic Chamber Testing Selected Tap Model Type Input Voltage '/4 W '/Y W 1 W* 2 W* (see note) (see note) 4902-9716CA Rectangular Housing* 25 VRMS or 70.7 VRMS 77 dBA 80 dBA 83 dBA 86 dBA 4902-9717CA 4902-9721CA Round Housing* 25 VRMS or 70.7 VRMS 79 dBA 82 dBA 85 dBA 89 dBA *NOTE: ULC Fire Alarm applications require use of 1 W or 2 W tap for Round Housing speakers;and 2 W tap for Rectangular Housing speakers. Speaker Polar Dispersion Reference(per ULC S541 Anechoic Chamber Testing) Attenuation Angle -3 dB 30°off-axis -6 dB 55°off-axis 4905-9931 Ada•ter Plate Installation Reference 0 2975-9145 Box 4905-9931 Adapter Plate _ M=M 0 O 4905 9999 n