HomeMy WebLinkAboutA14-0046_FA-001_1410798240.pdf Nial OF 1/4 44*13 14 id m LODGE AT vAIL _ UNIT 516 REMODEL ..„..t. ....., 70 0, 'af laol 1°1* :61P Vail Fire & Emergency Services 09/15/14 FIRE ALARM SYSTEM 'a a � c,Lo , u,u, cp MM t Sheet List Table N oM a E O j< 8 Sheet Number Sheet Title g m< SITE ° FA-001 COVER SHEET BUILDING CLASSIFICATIONS AND CODES .qlliii "' FA-101 DEVICE PLACEMENT PLAN, RISER DIAGRAM, AND CALCS C4 LODGE AT VAIL UNIT 516 REFV1ODEL FA-701 WIRING TYPICALS OCCUPANCY GROUP: R-2 USE: RESIDENTIAL CONDO E 0c0M = 8 8 STORIES: 6 STORIES (2 FLOOR CONDO UNIT IN SCOPE) (I) =00co FA-702 WIRING TYPICALS �; w 174 GORE CREEK DRIVE SQUARE FOOTAGE: TOTAL SQ. FT. UNKNOWN (APPROX 1,390 SQ. FT. IN SCOPE) 14 » 2 CO �ww SPRINKLED: FULLY BOO) " 0 VAIL , CO 8CODESA 72 2012 I.F.C. Q DEVICE A » ESS \ C LEGE \ 3 2011 N.E.C. o 2012 I.B.C. r FIRE ALARM WIRE LIST SYSTEM WIRING TYPES _ ADDRESSABLE CARD (IDNET OR MAPNET) CIRCUIT DESCRIPTION RISER RATED: FPLR SINGLE CONDUCTOR(THHN,TFFN) PLENUM RATED: FPLP INITIATING DEVICE CKT: CLASS B, STYLE B (HARDWIRED) INSTALLER NODE DESIGNATOR1 r DEVICE ADDRESS M MAPNET/IDNET CIRCUIT SG ANIX./PAIGE 740215 SG ANIX./PAIGE 740214L NOTIFICATION APPLIANCE CKT: CLASS B, STYLE Y (HARDWIRED) 2 1 PAIR 18 AWG TWISTED AREA=0.0196 SQ. INCH AREA=0.0196 SQ. INCH L 2:M2- 1 OVERALL SHIELD ANIXTER PART NUMBER ANIXTER PART NUMBER SIGNALING LINE CKT: CLASS B, STYLE 4 (ADDRESSABLE) 0) T740215 FAMC-1802C-1-2S-03B5 N 6' ADDRESSABLE DEVICES NUMBERING NETWORK: NOT APPLICABLE p POWER CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE ENCORE ELECTRIC 2 CONDUCTOR AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH SYSTEM TYPE o 14 AWG SOLID (SUBSCRIPT ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER SUPERVISING STATION TYPE: CENTRAL STATION ,. E CIRCUIT DESIGNATOR "r" IF RESETTABLE) FA-1402C-1-1N-03–BX AREA=0.0097 SQ. INCH (EACH) FA-1402C-1-2N-03 7 7 I\i/1 E T CA L F ROAD AUDIBLE NOTIFICATION: TEMPORAL NODE DESIGNATOR DEVICE DESIGNATOR S AUDIO CIRCUIT SG ANIX./PAIGE 454703ARE SG ANIX./PAIGE 740132R 1 PAIR 18 AWG TWISTED AREA=0.0204 SQ. INCH AREA=0.0141 SQ. INCH VISUAL NOTIFICATION: PUBLIC m UNSHIELDED ANIXTER PART NUMBER ANIXTER PART NUMBER "I,' o' 2:S2- 1 FA-1802C-1-1N-03–BX FA-180X-1-2N-03 J D O--5 AVON , CO 81620 // W o SPEAKER DEVICE Z ZONE CIRCUIT SG ANIX./PAIGE 454718ARE SG ANIX./PAIGE 454719ARE CI O 2 CONDUCTOR 14 AWG AREA=0.0380 SQ. INCH AREA=0.0333 SQ. INCH SCOPE OF WORK SOLID ANIXTER PART NUMBER (2) #14 AWG ANIXTER PART NUMBER W a) FA-1402C-1-2N-03 = ;v FA-1402C-1-1N-03–BX AREA=0.0097 SQ. INCH (EACH) � Q W (-) LODGE AT VAIL – CONDO UNIT 516: r 0 CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA I o 1 2" 0.12 SQ INCH * 1-1 4" 0.60 SQ INCH 3�4" 0.21 SQ INCH * 1-1/2" 0.82 SQ INCH * THE SCOPE OF WORK TO INCLUDE THE REMODEL OF 5TH/6TH FLOOR CONDO UNIT #516. W o 1" 0.34 SQ INCH * 2" 1.34 SQ INCH * INSTALL FOUR NEW SMOKE DETECTORS WITH SOUNDER BASES, ONE IN EACH BEDROOM, ONE Q FIRE AERN SYMBOLS LEGEND IN UPPER LEVEL HALLWAY AND ONE IN LOWER LEVEL KITCHEN AREA. THE EXISTING "M5" \\ 1- 1. — * Ct 40% FILL PER N.E.C. MAPNET SLC CIRCUIT AND EXISTING 24V POWER CIRCUIT ON 5TH FLOOR TO BE EXTENDED TO / W — > SYMBOL DESCRIPTION MODEL COMMONLY USED BACKBOX, REFER THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL NEW SMOKE DETECTORS. INSTALL TWO NEW C01224T CARBON MONOXIDE DETECTORS WITH IAM �/ D 6. TO DATA SHEET FOR OTHER OPTIONS MONITOR MODULES ONE IN UPPER LEVEL HALLWAY AND ONE IN LOWER LEVEL ENTRY CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE ' 0 HALLWAY. THE EXISTING 5TH FLOOR "M5" MAPNET CIRCUIT TO BE EXTENDED TO NEW IAM'S _ W ti SMOKE SENSOR / BASE SIMPLEX 4098-9714 SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS Q Q Lil o 2 SB = SOUNDER BASE SIMPLEX 4098-9794 BASE 4" OCTAGONAL BOX 1 1 2" DEEP AND 24V AUX POWER EXTENDED TO NEW CO DETECTORS. INSTALL THREE NEW SPEAKERS, ONE � C_O 15 OSB / CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT IN EACH BEDROOM AND ONE IN LOWER LEVEL COMMONS AREA AS SHOWN ON FLOORPLANS. w 0 Q DESIGN OF THIS SYSTEM INSTALLATION. DUE TO ARTWORK ON THE WALLS THE LOWER LEVEL SPEAKER TO BE INSTALLED AT APPROX. F- w CO REFERENCE htt s: www.anixter.com customer t cofs FOR SG ANIXTER CABLE DATA 10'-11' AFF (FIELD VERIFY WITH OWNER). THE EXISTING "S8" SPEAKER CIRCUIT ON 5TH C, i_ W r O , L u P /� Y FLOOR TO BE EXTENDED TO NEW SPEAKERS. MAINTAIN CIRCUIT INTEGRITY, T–TAPPING IS NOT Q E 01INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG BOX 2 1/2" DEEP WITH COVER O 0 PERMITTED. O 7 Q 0 J L THE SEQUENCE OF OPERATIONS MATRIX HAS BEEN REVISED TO INCLUDE THE CARBON 0 CARBON MONOXIDE SENSOR SYSTEM SENSOR C01224T SINGLE GANG BOX 2 1/2" DEEP MONOXIDE DETECTORS. J D 0 N OR DIRECT (SURFACE) MOUNT \ a 2 In" SPEAKER ONLY, WALL MOUNT SIMPLEX 4902-9717 4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" RING A #W = SPEAKER TAP **USE 70 VOLT TAP** W/4905-9942 ADAPTER SKIRT WHEN SURFACE MOUNTED .3 0 w END–OF–LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 Lodge at Vail – Sequence of Operations o 0 CO N mm Q �VV1r#K END–OF–LINE RESISTOR 4.7K (EOL) SIMPLEX 4081-9003 SYSTEM OUTPUTS / I O END–OF–LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 FACP Annunciation Notification Required Controls Supplementary / R END–OF–LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 FIRE DEPT./BLDG DEPT. PLAN REVIEW #: m , l D W 42 m a >. - E N o VA L F RE 8c EV EGENCY SERV CES o m N cn 2 w e ICI 7 Q o `O , 2399 NORTH FRONTAGE ROAD WEST 0 o 8 Luv w m VAIL, COLORADO 81657 o Y .o- o o aE) = o• �, o (970) 479-2252o N o �U O O` UC NNQ ~• C UC NO` .N CLO0V) 0 ..Q N — — .t IMIC(7 . Op :I"CV) ) o m aN dO 8 w 12 C N =' 2 N -OO O "' e) 8 ix d' C -,,- = ~ a cn N in o+ ur Z` N r m o 0 0 ° �` o 2 ` _,S 0 `° L co N N d 22 O C N N O E 75 .,.i c2 d C • `o v) a H O c a�0i N E oo N C .o 0 o, ,!,- D .3 c o Z E o o v, c `o . J m r C a C fn C U O m ° o , N O U ,/, C ` (n � O g N ? 2E2g2 .18 � � a = o0 ° NICETCERTIFICATION L _. Lf> O j O ' O E O O o li N H O O j CO a) d d a) d d w0+ = T .- '� 'E W W N o N N N O N O+ a U O O O O U O O N 2 0 2 N N N O O O O O 0 2 N o 2 o o > > C C > ] O_ C C C a) C 3 u, SYSTEM INPUTS ¢ a a ¢ a a ¢ �) s Z Z Z Z Z �) z A B c D E F G H J K L M N O P O R S T u V W X Y TECHNICAL AREA 00303: LEVEL 3 DRAWN BY: J. HABER E Si-mplexGri-nnell 1 Manual Pull Station - All Locations X X X X X X 1 CERTIFICATE83242 CL 2 Smoke Sensors - All Locations X X X X X X _ _ 2 #: CHECKED BY: S. SHARP cn 3 Smoke Sensor - Room Detectors Only X X X X _ 3 Expiration Date: 10/1/2014 ISSUE DATE: 8/22/14 L ` a 2 ›oJ Q 4 Smoke Sensor - 1st Floor Elev Lobby X X X X X X 4 JOB #: N 5 Smoke Sensor - Elevator Lobby x x x x x x x x 5 Design verification by SimplexGrinnell was provided to assure that o 6 Smoke Sensor - Elevator Machine Room X X X 6PROJECT#: 419:979951101 a L 7 Duct Smoke Sensor X X X X — X - 7 the system is being installed per NEPA 72. Verifications include SIMPLEXGRINNELL© 2014 o Safer. Smarter. Tyco. TM 6240 SMITH ROAD 8 Carbon Monoxide Sensor - Alarm A A A X X 8 Fire Alarm Control Panel, Notification Appliance Circuit, Initiating L 9 Carbon Monoxide Sensor — Trouble X X 9 o 10 Thermal Sensors - All Locations X X X X X X x X X 10 Device Circuit, and Battery/ Voltage Drop Calculations. Riser SYSTEM: FIRE ALARM SYSTEM a 11 Waterflow - Main X x x x x x x 1, Peripheral Device Details, Panel Details and General Information m N DENVER CO 80216 12 Sprinkler Control Valve - Tamper 13 FACP AC Power Failure X X X X XX X X 12 13 g providedSHEET: N are also bein rovided for the equipment installed with this 14 FACP Low Battery X X X X 14 system. 15 Open Circuit X X X X 15 L PROJECT COORDINATOR 16 Ground Fault X X X X 16 COVER SHEET 17 Notification Appliance Circuit Short X X X X 17 ° m � PHONE: 303-355-0500 ,$ Alarm Signal Silence X X 18 Q� JASON ROMERO A B C D E F G H J K L M N O P Q R S T U V W X Y ma SERVICE: 303-355-0500 NOTE: Audible Evacuation Signal shall be Temporal Pattern per NFPA 72 ^' * Disconnect power after a time delay equal to the time it takes for the car to travel from the highest to the lowest level plus 10 seconds. _ 414-1111111411111h w 3 0 3—3 5 5—0 5 0 0 * Audible Evacuation Signal shall be alert tone followed by voice direction-Speakers and strobes will activate by area of alarm. , • 8/25/ 4 FAX: 303-355-0615 •* Alarm areas are roam/condo tower, lodge, International wing. ' cw_) J A R O M E R O S I M P L E X G R I N N E L L E. .COM A = Alarm shall sound within the individual living unit only and shall not actuate the building fire alarm system. ` STEVE HA J FA 001 0 0 M a) X Q a, H O > N a a)