Loading...
HomeMy WebLinkAboutA14-0046_FA-701_1410798240.pdf ott OF p4. ..c.000141e. 44*.I3 idi ICC rill T DEVICE MOUNTING HEIGHT RHFERENCI-i: (PER NFPA 72) USE ONLY UL LISTED FIRE ALARM SIGNALING LINE (ADDRESSABLE) CIRCUITS SHIELDING EXAMPLE 0 TWISTED SHIELDED PAIR CABLE UL LISTED FIRE PROTECTIVE SIGNALING CABLES MAY BE SELECTED FROM THE SIMPLEXGRINNELL WIRE & CABLE TABLE, #WIRE TABLE CLASS 'A' (TSP) FOR IDNETS, DATA COMM. + + - - Jlaols%i VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS A/C SUPPLY v LINES, AUDIO, PHONE & SPEAKER MORN OR RETURN WIRING INA FIRE ALARM SYSTEM. PRODUCT INFORMATION 1. MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS MIN. SIZE IS 18-2 AWG SOLID STP. Vail Fire & Emergency Services DIFFUSER SCUT EXAMPLE: WIRING TECHNIQUES FOR SHIELDED CABLE: 9 y TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 09/15/14 2 #18-2 AWG SHIELDED • SHIELDS AND DRAINS MUST NEVER TOUCH GROUND. 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" 4" NOTE: MEASUREMENTS TWISTED-PAIR CABLE • MOST GROUNDS ARE DUE TSHIELDING ISSUES. (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' (MIN) (102mm) SHOWN ARE TO THE MOST SHORTS ARE SHIELD TOOO CONDUCTOR. t k. INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. CLOSEST EDGE OF THE • BY CREATING ASA PROPER PRCEDURE FOR WIRE (914mm MIN) CEILING TRIM AWAY ONLY HANDLING WITH ADDRESSABLE CIRCUITS DETECTOR. THE SHIELD AND of ' �1_,.; 1 o� // I MOST GROUNDS AND SHORTS CAN BE ELIMINATED. 1 KEEP THE DRAIN OIP WIRE UNDAMAGED. • ALL UNSHIELDED WIRE MUST BE ENTIRELY IN GROUND CONDUIT. in mmmmmmmm CEILING MOUNTED • CONDUIT SYSTEM MUST HAVE A GOOD REFERENCE TO EARTH GROUNDilli M� o L. FOR CEILING HEIGHTS LESS THAN 86" (2180mm), NFPA 72 AUDIBLE APPLIANCE 4" • PIGTAILS, (T-TAP) WIRING IS PERMITTED TO ADDRESSABLE DEVICES w THE VISUAL LENS MOUNTING HEIGHT SHALL BESMOKE/HEAT 102mmSHIELD FOR CLASS B CIRCUIT WIRING. z o 6" MIN (152.4mm MIN) DETECTOR ( ) 12" (MAX) a� o WITHIN 6" (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING + (305mm MAX) PREPARE THE CABLE BY DRAIN WIRE EXAMPLE FOR °‘16- N ` oHEAT DETECTORS REMOVING 2" TO 4" OF 4 WIRING LABELING l • 90" MIN (2286mm MIN) ACCEPTED HERE NEVER HERE II JACKET AS NEEDED. �� m ABOVE FINISHED FLOOR DISCARD TAIGE 9Li 5 ( ' (OTHER MOUNTING HEIGHTS SHALL BE ��I, LC)N� � � GENERAL WIRING GUIDELINES REUSE INSULATION SHIELD oNL PERMITTED BY THE AHJ PROVIDING IT ,/ N1.Mti ;- CLASS 'B' E a, oc0M AUDIBLE/VISUAL MEETS THE SOUND LEVEL OUTPUT REQUIRED.) / 1. ALL WIRING IS TO BE COPPER CONDUCTOR. ALL EQUIPMENT MUST + + - - C/� 7 =oM o BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS ° ,_ & VISUAL ONLY WALL MOUNTED RECOMMENDATIONS AND THE SPECIFICATIONS AND STANDARDS . °. v i c � 1 �"' APPLIANCES TO EXIT DOOR SMOKE/HEAT OF THE AUTHORITY HAVING JURISDICTION. THE INSTALLATION OF ,_- DRAIN WIRE TO PREVENT CONFUSION AND POSSIBLE ce oz5 5' (MAX.) DETECTOR ALL WIRING, CABLE AND EQUIPMENT MUST BE IN ACCORDANCE ERRORS, ALL WIRES MUST BE TAGGED. CO o �o� N WITH NFPA 70, NATIONAL ELECTRICAL CODE NEC), AND SPECIFICALLY SEE WIRE LEGEND FOR TYPES. WIRES MUST BE CONNECTED SYNCHRONIZE MORE THAN (1524mm) DOOR WITH ARTICLE 760, FIRE ALARM PROTECTIVE SIGNALING SYSTEMS; SEPARATELY UNDER TERMINALS. WIDTH ARTICLE 800, COMMUNICATION CIRCUITS, WHERE APPLICABLE. 0A CONTINUOUS WIRE LOOP TWO APPLIANCES IN ANY 2. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED: DRAIN WIRE IS NOT ALLOWED. i 4-, LESS 3" A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND (+) FIELD OF VIEW. 76mm INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE. STRIP OFF APPROX. RED ONLY CLASS B IDNET, MAPNET OR s o ( ) B. SHIELDS SHALL ONLY BE CONNECTED AT THE CONTROL UNIT. 1-2 INCHES OF PUSH REUSED INSULATION ti DATA COMM. CABLE MAY BE D 1 SHIELD MUST NOT BE CONNECTED TO, OR TOUCH CONDUIT, ELECTRICAL BLACK INSULATION TO CAREFULLY DOWN INTOAro N = 1 BOXES, OR ASSOCIATED HARDWARE AT ANY POINT. SLIDE ONTO DRAIN WIRE. JACKET. SECURE WITH T-TAPPED. IT MUST BE DONE Villi effillgir 96" MAX (NFPA, ADA) 5„ SIDE WALL C. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER k ELECTRICAL TAPE. IN A JUNCTION BOX WITHb. (2440mm MAX) (127mm THAN 1 MEGOHM TO EARTH. (-) CABLE STRAIN RELIEF I.E. t Q ) D. ALL CONDUCTORS ARE TO BE FREE OF SHORTS AND GROUNDS. / BLACK CORD CLAMP/BUSHING, AND ABOVE FINISHED FLOOR C 3. UNDERGROUND WIRING MUST BE LISTED FOR APPLICATION AND FREE OF ALL WATER. / TAPE WRAPPED AS SHOWN HERE. o REF. 80" MIN (IBC) MANUAL 4. WIRING OTHER THAN THAT CONNECTED TO ELEVATOR CABS MUST NOT BE RUN °' 80" MIN TO TOP OF LENS PULL IN ELEVATOR SHAFTS (REF.NFPA 70, ARTICLE 620). REDUCE EXPOSED WIRES TO © DRAIN WIRE m ( ) STATION 5. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE LISTED ABOUT 5/16" TO 3/8" FOR -- REF. 96" MAX (IBC) FOR PLENUM USE AND INSTALLED IN ACCORDANCE WITH NFPA 70, ARTICLE 300. INSERTION INTO BOX-TYPEli 80"a) MIN (ADA) (2032mm MIN) FIRE 6. SPLICING IS PERMITTED IN ACCORDANCE WITH NFPA 70. ALL JUNCTIONS MUST OR SCREW-CLAMP TERMINALS. STRIP THE INSULATED WIRES (2440mm MAX) BE INSULATED AS SOUNDLY AS THE ORIGINAL JACKET. CONTINUITY OF ANY SHIELD % ABOUT 5/16" TO 3/8" FOR s s. 80 MIN (NFPA) (2032mm MIN) PHONE MAGNETIC (WHERE USED) MUST BE MAINTAINED. ELECTRICAL TAPE. INSERTION INTO BOX-TYPE OR scs ABOVE FINISHED FLOOR JACK DOOR SCREW-CLAMP TERMINALS ON 8 SECURE THE E TO BOTTOM OF LENS FlPZI®® 7. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. DRAIN WIRES INTO HOLDER 8. THE COMMUNICATION CIRCUIT MEETS THE OPERATIONAL CHARACTERISTICS DEFINED FOR A STYLE 4 �7 THE ADDRESSABLE DEVICE. PUL 4 / THE CONNECTOR o �n o b ' • AND STYLE 6 SIGNALING LINE CIRCUIT. MAXIMUM WIRE RUN NOT TO EXCEED 2500 FT. / APPROVED FOR FINISHED 9. ALL CIRCUITS ARE SUPERVISED AND POWER-LIMITED UNLESS OTHERWISE INDICATED. SHIELD WIRES ARE NOT SUPERVISED. THE PURPOSE. 2 ® WALL 10. OPERATING POWER, FOR IDNet DEVICES, MUST ORIGINATE FROM A POWER-LIMITED POWER SUPPLY LISTED FOR FIRE 1/ WIRES MUST BE NOTE: REFER TO THE PROPER DEVICE PROTECTIVE SIGNALING USE OR, FROM THE F.A. CONTROL PANEL POWER SUPPLIES INDICATED IN THE APPROPRIATE ialfTIGHT ENOUGH t DIAGRAM. MAXIMUM WIRE NOT TO EXCEED 1KM (3270 FT). ��THE SHIELD/DRAIN IS NEVER TO HOLD SECURELY En INSTALLATION INSTRUCTIONS 48" MAX (ADA) (1219mm) CONNECTED TO THE DEVICE. J Y �' 11. WHEN COMMUNICATION WIRING OR OPERATING WIRING LEAVES THE BUILDING, OVERVOLTAGE PROTECTORS ARE AND NOT SLIP OUT N FOR BACKBOX MOUNTING HEIGHT. 48" MAX (NFPA, ADA) (1219mm EQUIRED; USE 2081-9044, INSTALL ONE WHERE IT LEAVES THE BUILDING AND ONE WHERE IT ENTERS THE NEXT BUILDING. �U km, 0OF THE CONNECTION. L1J N 03 FINISHED MAX)) 12. TO PREVENT CONFUSION AND POSSIBLE ERRORS, TAG ALL CONDUCTORS, CODE AT INSTALLATION, TO IDENTIFY ® ENSURE BARE DRAINS 0 42" MIN (NFPA) (1067mm MIN) CIRCUIT ASSIGNMENT, POLARITY AND IN OR OUT DIRECTION OF THE WIRING. LOG ON AS-BUILTS. ARE SECURED AND 0 LJJ r, FLOOR 13. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. UNABLE TO MAKE m MEASUREMENTS SHOWN ARE SIMPLEXGRINNELL IS NOT RESPONSIBLE FOR ELECTRICAL CONTRACTOR'S WIRE CONDITIONS. TRIM THE BARE DRAIN EXTERNAL CONTACT. 1 Q LJJ N c) 14. IDNet COMMUNICATION LINE SPECS.: TO ABOUT 1-1/2". JOIN SEE NOTE 2 Ct CD o TO TOP OF PULL HANDLE MAX. 36 VDC ® .5A 15. IDNET MAXIMUM NUMBER OF DEVICES: THEM WITH AN ELECTRICAL J O 0 I I \ w I I 3333 BAUD NON-CODED 250 CONNECTOR LISTED AND m 3352 MAX. LINE RESISTANCE CODED PIEZO BASES 43 MAX. APPROVED FOR WIRE SPLICING. < , LLI s 217 ADDRESSES STILL AVAILABLE FOR OTHER DEVICES. > C13 > LJJz o > PRODUCT INFORMATION 4098 - 9794 SOUNDER BASE PRODUCT INFORMATION 4090 - 9001 IDNET SLC , SUPERVISED ADDRESSABLE INPUT MODULE (AIM) �'�/ FEATURES: 4" OCTAGONALO1 1/2" (3.8 CM) DEEP 1..` w o 0 •FEATURES:LISTED IIS • UL LISTING STATUS: 4" SQUARE X 1 1/2" (3.8 CM) DEEP, i.6 -SENSOR AND SOUNDER OPERATION IS LISTED TO UL STANDARD 268 • ADDRESSABLE COMMUNICATIONS SUPPLY BOTH DATA LJJ -SOUNDER W/RACO 787 ADAPTER BRACKET, Q Ct CO SOUNDER OPERATION IS ALSO LISTED AS AN AUDIBLE NOTIFICATION AND POWER TO PROVIDE: UL LISTED SINGLE 0 SUPPLIED BY CONTRACTOR - SUPERVISED STYLE B MONITORING OF NORMALLY OPEN DRY CONTACTS. GANG ELECTRICAL BOX (2 1/8" MIN. DEPTH) w 5 E- APPLIANCE TO UL STANDARD 464 BY 00 A 4098-9832 ADAPTER PLATE IS REQUIRED - COMMUNICATIONS WIRING USING ONE TWISTED, SHIELDED WIRE PAIR. (SUPPLIEDCONTRACTOR) n 1- w w • MODULAR TRUEALARM SENSOR BASE WITH BUILT-IN ELECTRONIC ALARM SOUNDER: FOR SURFACE MOUNTING TO • COMPATIBLE WITH SIMPLEX ADDRESSABLE FIRE ALARM CONTROL PANELS. ® 1 V ¢ 0 J -SOUNDER CAN BE POWERED FROM 24 VDC OR FROM A COMPATIBLE MAPNET II ZDNet ADDRESS DIP SWITCHES ®� / OCTAGONAL BOX • COMPACT, SEALED CONSTRUCTION: .� g'- 7_ NOTIFICATION APPLIANCE CIRCUIT (NAC SEE BASE INSTALLATION INSTRUCTIONS 574-709 FOR SETTING. w 0 0 -SOUNDER CAN BE SYNCHRONIZED CODED/TEMPORAL CODED BY ' - ALLOWS MOUNTING IN A SINGLE GANG BOX1 <40 �- 0 U, THE FIRST EIGHT DIP SWITCHES SET THE SOUNDER BASE ADDRESS. -�!. _% C� COMMUNICATIONS OR BY THE NAC SWITCH 9 IS SET TO "ON" WHEN SOUNDER BASED IS POWERED FROM �� - REDUCES DUST INFILTRATION �� 0 I 0 -SOUNDER CAN BE MANUALLY ACTIVATED FROM THE CONTROL PANEL PANEL'S NOTIFICATION APPLIANCE CIRCUIT (NAC). • PROVIDES CURRENT LIMITED MONITORING N -BUILT-IN MAGNETIC TEST FEATURE SWITCH 9 IS SET TO "OFF" WHEN SOUNDER BASED IS POWERED FROM O - TO MONITOR TAMPER SWITCH (SUPERVISORY) AND 4090-9810 BRACKET 0 ti Q -FOR USE WITH INTERCHANGEABLE TRUEALARM SENSORS; A 24 VDC POWER SOURCE. ,` WATER FLOW SWITCH (ALARM) ON SAME CIRCUIT REQUIRED WHEN USING J PHOTOELECTRIC SMOKE SENSOR 4098-9714: REQUIRES ONLY ONE ADDRESSABLE POINT THE SIMPLEX TRIM PLATES � _ •o SEVEN LEVELS OF SENSITIVITY FROM 0.2% TO 3.7% • SELECTABLE LATCHING OPERATION OPTIONAL WHEN USING ` )1r1114:"--7----------17AHx 0 s IONIZATION SMOKE SENSOR 4098-9717: A CONTRACTOR SUPPLIED ;' �I�� Tm a- MONITORS MOMENTARY CONTACT CLOSURES SUCH AS - I1 FOUR LEVELS OF SENSITIVITY FROM 0.5% TO 1.7%. Wilk �� RATE-OF RISE HEAT DETECTORS BACK BOX COVER OPTIONS; SINGLE GANG COVER ` 31MREITIIDAE � �" /a HEAT SENSOR 4098-9733: 4098-9714 PHOTOELECTRIC SMOKE SENSOR \-; `�' '� .4,/ SEMI-FLUSH TRIM PLATE 4090-9806 (SHOWN) ` - 40909001 -RATE-OF-RISE TEMPERATURE DETECTION IS SELECTABLE AT THE CONTROL PANEL FOR EITHER 15°F 4098-9717 IONIZATION SMOKE SENSOR ( % o` jLJ� SPECIFICATIONS: WITH LIGHT PIPE FOR LED VIEWING »>' 7 ',.swa ,/ 3 0 ct OR 20°F PER MINUTE �,;i' o SURFACE TRIM PLATE 4090-9807 ISI I DATECDDE, NI� gw -FIXED TEMPERATURE SENSING IS INDEPENDENT OF RATE-OF-RISE AND PROGRAMMABLE TO OPERATE • WIRE CONNECTIONS: SCREW TERMINALS FOR IN/OUT WIRING �_m 4098-9733 HEAT SENSOR ° FOR WIRE FROM #18 TO #14 AWG. WITH LIGHT PIPE FOR LED VIEWING I� M cAT 135°F OR 155°F yQ -TRUEALARM HEAT SENSORS CAN BE PROGRAMMED ASA UTILITY DEVICE TO MONITOR / \ I ! DIMENSIONS: 1 9/16" X 1 3/4" X 1 1/4" SINGLE GANG COVER W/ 2 6/32 uuoDuaoD _ " = FOR TEMPERATURE EXTREMES IN THE RANGE FROM 32° F TO 120° F. �\ ':III; \/• ,' FLATHEAD SCREWS i ; O �` • TEMPERATURE RANGE: 32° F TO 158° F (0° C TO 70° C) (SUPPLIED BY CONTRACTOR) III • TRUEALARM ANALOG SENSING OPERATION: ' / / lay ct• HUMIDITY: UP TO 93% RH AT 100° F-ANALOG SENSOR INFORMATION IS DIGITALLY COMMUNICATED TO THE CONTROL PANEL VIA MAPNET II OR IDNet SLC, TWO-WIRE COMMUNICATIONS • SUPERVISION RESISTOR: 6.8kn 1/2W, (SUPPLIED) _eE 6 -SENSOR INFORMATION IS PROCESSED BY THE CONTROL PANEL TO DETERMINE SENSOR STATUS _ • UL STANDARD SPACING FOR HEAT SENSOR: f.h.\\ f SIMPLEX PART N0. 733 886 / • RESISTOR FOR CURRENT LIMITED OPERATION: 4.7k52 1/2W, III _�� ADDRESS DIP SWITCHES UNDER I I1 - -60 FT SPACING FOR 135° F FLUSH MOUNTING WITH A 1.8kn 1/2W o III RE-SEALABLE LABEL z m Ecn -40 FT SPACING FOR 155° F , ' SEE INSTALLATION INSTRUCTIONS o o Ea . (BOX TO BE FLUSH OR RECESSED 1/4" MAXIMUM) • INPUT REQUIREMENTS: NORMALLY OPEN, DRY CONTACTS J • INTEGRAL RED LED FOR POWER-ON (PULSING), OR ALARM OR TROUBLE (STEADY ON) ® �� (574-331) FOR SETTINGS F ° / • HOUSING MATERIAL: BLACK THERMOPLASTIC -�! I o • BASE MOUNTED ADDRESS SELECTION: Cl) m -ACCESSIBLE FROM FRONT (DIP SWITCH UNDER SENSOR) FROM PANEL DESCRIPTION: _�,,.. o E m -ADDRESS REMAINS WITH ITS PROGRAMMED LOCATION . e r-�-. THE 4090-9001 IS AN ADDRESSABLE INPUT MODULE (AIM) Y • MOUNTING: CEILING OR WALL WITH POWER AND COMMUNICATIONS SUPPLIED BY A TWO WIRE ADDRESSABLE N WIRING NOTES: +24V OR OV OR CIRCUIT. IT PROVIDES LOCATION SPECIFIC ADDRESSABILITY E_ m °� 1❑. REMOTE LED WIRES ARE NOT SUPERVISED. NAC +ALM-a,- NAC -ALM TO A SINGLE INITIATING DEVICE (SUCH AS SINGLE STATION SMOKE _e o = Q MAXIMUM QUANTITY OF DEVICES PER CIRCUIT IS 127 FOR 4020, 4100+, OR 4120, DETECTOR ALARM CONTACTS OR HEAT DETECTOR CONTACTS) OR o 128 FOR THE 2120 CDT AND 250 FOR THE 4010 PANEL. + TO NEXT MULTIPLE DEVICES AT THE SAME LOCATION BY MONITORING ❑3 IF SHIELD IS PRESENT, CONNECT TO THE OUTGOING IDNet SLC SHIELD I I - - 24V OR NAC NORMALLY OPEN, DRY CONTACTS AND THE WIRING TO AN END-OF-LINE RESISTOR. u, g g cc i TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE - DEVICE CLOSURE OF THE MONITORED CONTACTS INITIATES AN ALARM OR ~ 77 OTHER RESPONSE AS PROGRAMMED AT THE FIRE ALARM 6 ❑ TO ADDITIONAL m 77 ai IDNet SLC CHANNEL. METHOD OF SPLICE DETERMINED BY AHJ. ❑ OPTIONAL SHIELD 6 o 2 CONTROL PANEL. AN OPEN IN THE MONITORED CIRCUIT WIRING FROM UL-LISTED SHIELD-S • • S- SHIELD DEVICES OR RETURN 4. THE 4098-9794 IS NOT COMPATIBLE WITH 2120 CDT. WILL CAUSE A TROUBLE TO BE REPORTED. F.A.C.P. OR TO FIRE ALARM w Y ,z• 0 5. MAXIMUM QUANTITY OF SENSORS WITH 4098-9794 SOUNDER BASES LIMITED TO 43 BLUE }- NO CONNECTION IF THE INITIATING DEVICE CONTACTS ARE MOMENTARY, SUCH AS PREVIOUS ZDNet MAPNET + - R R- + ZDNet MAPNET m 3 / / CONTROL PANEL FOR cn a , Ea E. IF OUTPUT IS CODED (TEMPORAL CODE, ETC.) VIA MAPNET II/ZDNet SLC CONTROL. FROM A RATE-OF-RISE HEAT DETECTOR, ENABLING THE LATCH SLC DEVICE IDNet/MAPNET - - B B- - ZDNet/MAPNET STYLE 6 SYSTEM u) a IF CODING IS PERFORMED VIA 24 VDC OR NAC CIRCUIT. SEE NOTE 2. IU FEATURE WILL MAINTAIN THE ALARM CONDITION UNTIL THE SYSTEM Z Z 3 b Z 3 APPLICATION t N I I� IS RESET. FOR APPLICATIONS WHERE THE CONTACT CLOSURE LATCHES, S ,, M WHITE PRIMARY ZDNet/MAPNET SLC LINES I 2 I 2 SPECIFICATIONS: GENERAL OPERATING SPECIFICATIONS I OR IF ITS CONDITION NEEDS TO BE TRACKED AT THE CONTROL PANEL T-SENSING OPERATION: 2 o - NON-LATCHING OPERATION MAY BE ENABLED. II El 10 �_-o- r_-o_- SECONDARY IDNet/MAPNET SLC LINES m m w MAPNET II OR IDNet SLC AUTO-SELECT 24-40 VDC W/DATA, 400 uA TYPICAL .,� • SUPERVISED INPUT: - r` �'� r�h �� 5 $ 9 D , a 1- COMMUNICATIONS AND SENSOR SUPERVISORY POWER 1 ADDRESS PER BASE, SUPPLIED BY CONTROL PANEL WIRING NOTES: - 4090-9001 AIM WITH T-SENSE CAPABILITY HAS A CI] �D [I> ❑ ❑ ❑ ❑ DRAWN BY: J. HABER E COMMUNICATIONS AND SOUNDER POWER CONNECTIONS SCREW TERMINALS FOR IN/OUT WIRING #18 TO #14AWG 1. ALL WIRING TO COMPLY WITH LOCAL CODE. SUPERVISED INPUT THAT MONITORS FOR CONTINUITY IM 1 Imo I € o_ REMOTE LED ALARM CURRENT 1 mA 1YPICAL SUPPLIED FRO COMMUMCAIIONS. NO IMPACT 10 ALARM CURRENT- , , p I I 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. CHECKED BY: S. SHARP2 Pi TO AN END-OF-LINE RESISTOR AND CAN DIFFERENTIATE _ INDICATOR 2098-9808 LED CONNECTIONS COLOR CODED WIR LEADS 18 AWG �I� BETWEEN A SHORT CIRCUIT CONTACT CLOSURE AND I] [I �I] [I] ISSUE DATE: 8/22/14 a UL LISTED TEMPERATURE RANGE 32° F TO 100° F 0° C TO 8° C S 3. ONLY N.O. DRY CONTACTS ARE ALLOWED. L- -:J� _.J CURRENT LIMITED CONTACT CLOSURE. JOB #: m N OPERATING WITH 4098-9717 OR 4098-9733 32° F TO 122° F 0° C TO 50° C +COMCIM 4. MAXIMUM WIRE LENGTH (NO. 18 AWG) IS 400 FT. W/2081-9044 INII .4 WWI TEMPERATURE RANGEWITH 4098-9714 15° F TO 122° F -9° C TO 50° C) OVER VOLTAGE PROTECTORS OR 400 FT. W/O PROTECTORS. • FOUR STATE OPERATION: 4 PROJECT#: 419:979951101 HUMIDITY RANGE 10 TO 95% RH Ia.,I q 5. A MAXIMUM QUANTITY OF DEVICES PER CIRCUIT: CONTROL PANEL - NORMAL IS WHEN ALL CONTACTS ARE OPEN AND THERE SMOKE SENSOR AIR 4098-9714 PHOTOELECTRIC SENSOR 0-2000 FT MIN (0-610 M/MIN) MODULE DEPENDENT IS CONTINUITY TO THE END-OF-LINE RESISTOR. SIMPLEXGRINNELL© 2014 VELOCITY RANGE 4098-9717, IONIZATION SENSOR 0-200 FT/MIN (0-61 M/MIN) 6. IF SHIELD IS PRESENT, CONNECT TO THE OUTGOING ZDNet SHIELD - OPEN IS WHEN CONTINUITY DOES NOT EXIST TO THE END-OF-LINE _ SYSTEM: N HOUSING COLOR FROST WHITE II 11 TO PROVIDE A CONTINUOUS SHIELD OVER THE LENGTH OF THE RESISTOR, CAUSING A TROUBLE CONDITION. 3❑ ( 733 �2W) 3❑ FIRE ALARM SYSTEM IDNet CHANNEL. METHOD OF SPLICE DETERMINED BY AHJ. - SHORT, INDICATES THAT A CONTACT HAS CLOSED THAT IS 1 8K 1 '2 Y SOUNDER OPERATING SPECIFICATIONS m.N 7. REFER TO INSTALLATION INSTRUCTIONS 574-331. DIRECTLY CONNECTED TO THE INPUT CIRCUIT. SHEET: m N SOUNDER VOLTAG 18 TO 32 VDC FROM STEADY EXTERNAL SOURCE OF FROM NAC II 11 8. MAXIMUM ALLOWABLE LINE RUN FROM THE F.A.C.P. TO THE - CURRENT LIMITED INDICATES THAT A CONTACT HAS aN ALARM CURRENT SOUNDER ON) 17 mA 24 VDC, 20 mA MAXIMUM © 32VDC FARTHEST DEVICE, NOT TO EXCEED 2500 FEET. CLOSED BEYOND A SERIES CONNECTED CURRENT t 88 dBA MINIMUM © 10 F. PER UL STANDARD 464, AUDIBLE SIGNALING APPLIANCE 9. MAXIMUM TOTAL WIRE (INCLUDING ALL T-TAPS) FROM THE LIMITING RESISTOR. THIS OPERATION ALLOWS SOUNDER OUTPUT APPLIANCES AND UL STANDARD 268, SMOKE DETECTORS FOR FIRE PROTECTIVE FIRE ALARM CONTROL PANEL DIFFERENTIATION BETWEEN TWO DIFFERENT CONTACT 73 _896 733-886 WIRING TYPICALS SIGNALING SYSTEMS `� TYPES DUE TO THEIR WIRING LOCATION, AND REPORTING 6 8K 1 m N SOUNDER POWER SUPERVISION SUPERVISED SELECT FOR CONTINUOUS 24 VDC POWER, LOSS OF POWER IS COMMUNICATED TO PANEL FROM PREVIOUS TO ADDITIONAL ❑2 10. FOR STYLE 6 CIRCUIT WIRING IT IS RECOMMENDED (4.7K 1/2W) ( /2W) (SELECTABLE) UNSUPERVISED SELECT WHEN CONNECTED TO NAC FOR SOUNDER POWER, NAC PROVIDES SUPERVISION MAPNET II/ZDNet SLC I I MAPNET II/ZDNet SLC THAT THE PRIMARY 1O AND THE BACK-UP®LINES AS A SINGLE IDNET ADDRESSABLE POINT TO A - JL DEVICES OR RETURN TO BE IN SEPARATE WIRE RUNS AND IN COMPLIANCE 41000 FIRE ALARM CONTROL PANEL. WIRING FOR CURRENT LIMITED OPERATION m NAC POWERED OPERATION WHEN IN ALARM, WILL SOUND WHEN NAC IN ALARM, ALLOWING SYNCHRONIZED CODING DEVICE OR FIRE - - - - -i CONTROL PANEL FOR STYLE WITH LOCAL REQUIREMENTS. m c, (TEMPORAL OR MARCH TIME, ETC.) CONTROLLED BY THE NAC CONTROL PANEL - SHIELD 0 - 6 OR 7 OPERATION 11. REFER TO FIELD WIRING DIAGRAM 842-073 0 of L LE T Q U m FA-701 co O X Q N F . H N 0 ,, a C .a,