HomeMy WebLinkAboutA14-0056 FA-00 4 44 41714 OF Vot _ °Applie. A14-0056 4fri Received Address Type of Device Level Description m 001 SMOKE DETECTOR LOWER SMOKE AT FACP LEGEND:��WN OF VAIL By Carolyn Godfrey at 12:59 pm, Sep 17, 2014 002 MONITOR POINT LOWER SPRINKLER WATERFLOWow silt 003 MONITOR POINT LOWER SPRINKLER TAMPER SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 004 HEAT DETECTOR LOWER BUNK ROOM 005 CO/SMOKE DETECTOR LOWER BOTTOM OF STAIRS FACP Caddx (NetworkX) NX-8E - 1001 006 HEAT DETECTOR LOWER GARAGE Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox 007 CO/SMOKE DETECTOR MAIN GREAT ROOM 008 CO/SMOKE DETECTOR MAIN HALL OUTSIDE BEDROOMS KP Vail Fire & Emergency Services 009 CO/SMOKE DETECTOR _MAIN MASTER BEDROOM LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox 10/13/14 010 CO/SMOKE DETECTOR MAIN LIVING ROOM Combination Smoke & M MONITOR SPRINKLER WATERFLOW & TAMPER 011 CO/SMOKE DETECTOR UPPER TOP OF STAIRS Q2 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box M SWITCH WITH ADDRESSABLE MODULES. USE 012 SMOKE DETECTOR UPPER WEST BEDROOM ZONES 002 & 003. 013 SMOKE DETECTOR UPPER BUNK ROOM Combination Smoke and 014 SMOKE DETECTOR UPPER EAST BEDROOM Om CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 015 SMOKE DETECTOR UPPER SOUTH BEDROOM I 016 O 017 Heat Detector System Sensor 5601P 4" square box o SNOW MELT V 018 E BOILER ) 1 8" RAISED PLATFORM 010 C U LAUNDRY 020 ❑ Cosmo Interface Module COSMOD4W o MECH 0FALSE LOG FALSE LOG 021 0 -, BEAM BEAM 022 M❑ Addressable Monitor Module SI-ID Addressable Module w BOILERi 024 cc SA .--i- > 1 .0R. 0, THEATER 025 Ke Knox Box 027 028 Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox 029 Lii 1 - 030 GENERAL NOTES: o u LOf KER - \ I , 031 032 - - 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH rz TABLE 033MANUFACTURER STANDARDS34 , FIRE DEPARTMENT REQUIREMENTS AND NEPA 72. z4 _ L 035 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR TO FACP - - 036 FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, ci I- r ® [ / 037 PROGRAMMING AND DEVICE OPERATION. o z CO 038 El \ 039 (3.3 < 040 U r NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. E cp c) 0 IL (.1) _ iii c/) W Battery Calculations c w 1 Caddx NX-8E %°1- 0 o z a 1 Standby 0 0 mi / I \ Number of Current Total Current TO FACP Device Type Devices (Amps) (Amps) _ Main FACP CPU 1 X 0.075 = 0.075 J 0 NX-14E LCD Keypad 1 X 0.075 = 0.075 C 006 i3 Smoke Detector with Sounder 5 X 0.00005 = 0.00025 (1) Wi4 COSMO Smoke/CO Detector w/Sounder 6 X 0.00005 = 0.0003 COSMO Interface Module 2 X 0.052 = 0.104 r - I. C T SI ID Addressable Module 9 X 0.00025 = 0.00225 SUM COLUMN FOR STANDBY LOAD 0.2568 = AMPS D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) _AOJ 0 GARAGE Alarm Load - \ I / Number of Current Total Current X = 2-WIRE DATA, 2-#16AWG l\ Device Type Devices (Amps) (Amps) N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG 0 \ Main FACP CPU 1 X 0.14 = 0.14 0 \ NX-14E LCD Keypad 1 X- 0.11 = 0.11 L = 2-WIRE DATA CIRCUIT, 2-#16AWG (1) - \ \ i3 Smoke Detector with Sounder - - -5 X 0.025 = 0.125 KP = KEYPAD CIRCUITING, 4-#18AWG 0 1 i4 COSMO Smoke/CO Detector w/Sounder 6 X 0.04 = 0.24C O �_ COSMO Interface Module 2 0.052 0.104 op 004 GAS METER 1 = - RISER NOTES: i1 ® x i I SLID Addressable Module 9 X 0.040.36 O 9'OWX8'OH OHD 9'OWX8'OH OHD -0 - - I Outside Horn/Strobe 1 X 0.212 = 0.212 1. REFER TO CADDX NX-8E INSTALLATION MANUAL C3 E TO FACP 1 ELECTRIC SERVICE I SUM COLUMN FOR ALARM LOAD 1.291 = AMPS FOR MORE INFORMATION. 0 < METER I Standby Load Required Standby Time in Hours 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS n OJ BUNK ) Current (Amps) MANUFACTURERS SPECIFICATIONS. Qco 1 O O 0.2568 X 24 - 6.16 \ 0 U / Alarm Load Required Alarm Time in Hours 9D D X x O O I / Current (Amps) (15 MINUTES} cD (U p d -n- - - - - - 1.291 X 0.25 = 0.32 L,N I;-I L,N d L,N M o E Add Standby and Alarm Load for Required 120VAC DEDICATED POWER NX8E I_ Ampere Hour Battery 6.49 CONTROL PANEL (TYP) (TYP) (TYP) Multiply by the Derating Factor of 1.2 Total Ampere Hours Required = ?1S TELEPHONE LINE - FIRE BELL NWP 'Minimum Battery Size Provided: 12AH TELEPHONE LINE - SECURITY OUTPUT IQ EOLR All fire alarm DATA/COM KP CADDX RISER DIAGRAM OUTPUT NX148 systems installed in Stamped a rovedplans KEYPAD CL ypp the Town of Vail andpermit are re uired toq - 100 % 111 kept on ' obsite andsh be \ Ce 00 a • • essable(0 available at time ofI 0 l 0 z inspection . PROJECT INFORMATION : I w Q annunciation . See SEQUENCE OF z J 381 6 LU P N E DRIVE '�.� G��. CL VFES fire alarm QOPERATIONS: VA L, COLORADOf. jtP ' J Q coo 0o cno ori zQ : v^. 352301 CL installation m ~ N ~ ~ N �� M . � N � N mN FIRE ALARM SYSTEM _ . r ; , .= Co 0 D H > H wH - 0o t, ■ LOWI- R FLOOR o_ < z z z a m w w AHJ: VAIL FIRE & EMERGENCY SERVICES 'y �s;""'' "' WLIJ �t�l n d a rd s . a o 0 0 Q I o APPLICABLE CODES: 2010 NEPA 72, 2012 IFC, 2012I- 0 CO0 SCALE: 1 /4" = 1 ' 1- � o � o � o � w � �' W w mz mz mz ww I LAE ow OCCUPANCY: GROUP R 0 >- DEVICE > z -. z z - > w > z >z USE: SINGLE FAMILY HOME < C1) m DESCRIPTION Q Q Q Q H o H o H o Q m < o < o FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM WILL INCLUDE A INSTALLATION NOTES: - - - CL 0 SMOKE DETECTOR X X NEW ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE D J Q w 1 . SMOKE DETECTORS IN SLEEPING ROOMS SHALL BE CENTERED ALONG ONE WALL OF ROOM AND LOCATED A MINIMUM OF 12" OFF THAT WALL. INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON W 0 Q z 2. COSMO DEVICES REQUIRE A 6-CONDUCTOR HOME RUN TO COSMO4 MODULE AT FACP. X X STAIRWELL LANDINGS, WITHIN 15' OF FIREPLACES AND AREAS OUTSIDE OF I- < 0 HEAT DETECTOR SLEEPING ROOMS. A HEAT DETECTOR WILL BE INSTALLED IN THE Q J W C!) GARAGE. DETECTORS HAVE INTEGRAL SOUNDERS. A KNOX BOX WILL BE = Q i W CARBON MONOXIDE DETECTOR X X X X MOUNTED ON THE OUTSIDE OF THE HOME. U > LL 0 SPRINKLER WATERFLOW SWITCH X X X SHEET DESCRIPTION: FIRE PROTECTION ENGINEER: COVER SHEET SPRINKLER TAMPER SWITCH X X DEBORAH SHANER, P.E., SHANER LIFE SAFETY DRAWN BY: DATE: PO BOX 1073, FRISCO, CO 80443 POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X PHONE: 970-409-9082 DLS 9/8/14 FAX: 970-797- 1898 SHEET#: FA-00