HomeMy WebLinkAboutA14-0067_FA-00_1414617060.pdf Received *Ai OF 1,4 WN O f TOVAIL ' By Carolyn Godfrey at 8:26 am, Oct 23, 2014 �• Z.? ibilly frii. TOWN U A14-0067 LEGEND : ' . st SEQUENCE OF Z J J z SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 0 D cn Q 0 J ^ - *' J Z + OPERATIONS : N- Z Q z CO z Q z FACP Mount on wall in w < O z O cn O >- z U OJ ct Fire Alarm Control Panel Firelite MS-9200 manufacturer backbox m w 2 - H H f O w w O - Vail Fire & Emergency Services J v) < J < O I- m i U ❑F Single gang or 10/29/14 0 o I- I- - I- Cl) < rx o w w Manual Pull Station Firelite BG12LX 4" square box Q > > O O O w O O- v) o w Single gang or a w Q J g z z w z Q > 1- > Addressable Photo Smoke Detector Firelite SD355 4" square box E U J U < ~ W w to Z O U LI Q v N O O (n 0 J w z O Q O Single gang or w w w Z z I_ Z w w W w 1 Addressable Heat Detector Firelite H355 4" square box z DEVICE Q ~a w z o z o 07 0 z w Q <1 > o 0 DESCRIPTION 1 E j Q Q D oO -- o_ U 1 CR Control Relay Firelite CRF-300 4" square box w 0 O o 1- O 1- o O cn w z 0 Q cn © _Mini Monitor Module Firelite MMF-301 4" square box MANUAL PULL STATIONS X X X ��� Wall Mount: System Sensor SW 4" square box _ ' Strobe Ceiling Mount: System Sensor SCW 4" square box Approved as noted . Wall Mount: System Sensor P2W 4" square box SMOKE DETECTOR X X X Horn/Strobe Ceiling Mount: System Sensor PC2W 4" square box Lii0 I....ocation of FACP not LCD Mount on wall in ELEV LOBBY/SHAFT/EQUIP RM SMOKE X X X X LCD Annunciator Firelite ANN-80 manufacturer backbox o z approved . As built pp will be provided sELEV SHAFT/EQUIP RM HEAT DETECTOR X X X X X (f) drawing afterfinal i WATERFLOWSWITCH X X X X Z ae 0 VALVE TAMPER SWITCH X X I- I- U AC POWER LOSS X X 75CD 75CD 15CD 15CD J O CV C N FU. F:), F:), EOLR LLI co GROUND FAULT X X71- N- J cc co co N 75CD 75CD 15CD 15CD X o OPEN CIRCUIT/SHORT CIRCUIT X X EOLR = O FLOW/ ELEVATOR TAMPER FUNCTIONS NEW NAC CIRCUITS • 0 Z CD NOTE: ELEVATOR RECALL CONSISTS OF PRIMARY AND SECONDARY RECALL. PRIMARY RECALL MS9200 CO C, IS TO THE MAIN LEVEL, SECONDARY IS TO THE LOWER LEVEL. PRIMARY RECALL OCCURS © © 0 L FACP 75CD 75CD 15CD 15CD CO < WHEN THE SMOKE DETECTORS IN THE ELEVATOR EQUIPMENT ROOM, SHAFT, OR ELEVATOR TYP TYP TYP TYN �O, EOLR (...0LOBBIES ACTIVATE. SECONDARY RECALL OCCURS WHEN THE SMOKE DETECTOR LOCATED IN P TYP THE MAIN LEVEL ELEVATOR LOBBY ACTIVATES. EXISTING NAC CIRCUIT (REPLACE HORNS WITH HORN/STROBES) LCD A DEDICATED 120V i TELEPHONE LINES eFire1ITe Alarms MS-9200 Battery Calculation SYSTEM ONE LINE DIAGRAM Regulated Load in Standby NOTE: INSTALL A POWER SUPPLY IF NECESSARY. Number of I I Total Current Device Type Current(Amps) �i�� Devices (Amps) 111•••• .f■ f:1 Main Circuit Board 1 x 0.020000 = 0.220000 FIRE ALARM WIRE TYPE CHART IPDACT-2 1 x 0.093000 ANN-80(-VV) 1 x 0.015000 = 0.015000 Label Description Wire Type SD355 45 x 0.000300 = 0.013500 AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) H355 10 x 0.000300 = 0.003000 L Signaling Line Circuit #16 AWG Twisted Pair MMF-301 6 x 0.000375 = 0.002250 P 24VDC Power Wiring 2#14 AWG Solid BG-12LX 12 x 0.000230 = 0.002760 N Notification Appliance (Horn/Strobe) Wiring 2#14 AWG Solid CRF 300 4 x 0.000270 = 0.001080 X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid Current Draw from TB3-EIA-485 0.000000 4Total Standby Load 0.257590 I Z Indicating Device Circuit (Zone) Wiring 2#16 AWG Solid A Annunciator Wiring 2x #16 AWG Twisted Pair OP CO Regulated Load in ALARM NOTE: 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT Number of Total Current Device Type Devices I Current(Amps) (Amps) Main Circuit Board 1 x 0.200000 = 0.200000 IPDACT-2 1 x 0.136000 = 0.136000 ANN-80(-W) 1 x 0.040000 = 0.040000 ALL Addressable Devices- Maximum draw 1 x 1.200000 = 1.200000 PROJECT INFORMATION : rn w NAC#1 2 1 x 2.510000 = 2.510000 CAC#2 1 x 0.000000 = 2.500000 G O S U C H , VAIL VILLAGE STORE 0 wCi- Current Draw from TB3-EIA-4$5 0.000000 = 3Total Alarm Load • :.,,, 263 E. GORE CREEK DRIVE, VAIL, COLORADO U v w Total Calculations FIRE ALAR IV SYSTEV W J zz z Use the total standbyand alarm load currents calculated in tables A-2A and A-2B for the following0 Q AHJ: VAIL FIRE 8c EMERGENCY SERVICES Q > � _ battery calculations APPLICABLE CODES: 2012 IBC, 2012 IFC, 2010 NFPA 72 I U U) Required Standby Time in Hours co > W (24 or 60 Hrs.) THE SCOPE OF WORK FOR THIS PERMIT INCLUDES A FIRE ALARM SYSTEM REPLACEMENT W J Q Standby Load Current(Amps) 0.257590 1 x 24 = 6.182 AH PLUS WORK TO ACCOMMODATE A REMODEL. THE NEW PANEL IS A FIRELITE MS9200, 0 • W cL Required Alarm Time in Hours ADDRESSABLE. EXISTING DEVICES IN THE EXISTING (NON-CONSTRUCTION) AREAS ARE BEING J ° J O (15 minutes = 0.25) REPLACED ON A ONE-FOR-ONE BASIS. EXISTING HORNS WILL BE REPLACED WITH Alarm Load Current(Amps) 6.586000 1 x 0.25 = 1.647 AH, HORN/STROBES. CO J W D W Total Current Load 7.829 AH A NEW LCD ANNUNCIATOR IS BEING INSTALLED AT THE FRONT ENTRY. > rW 1- 0 Multiply by the Derating Factor 1.2 = x 1.20 J WIRING IS NOT SHOWN FOR EXISTING DEVICES BECAUSE THE WIRING IS ALSO EXISTING. 0 >- Total Ampere Hours Required 9.394 AH Q O THE BUILDING IS PARTIALLY SPRINKLERED. ALL EXISTING FLOW AND TAMPER SWITCHES WILL > H 0 BE MONITORED. U � 0 W A ZONE LIST WILL BE PROVIDED AT THE FINAL INSPECTION. D C Z �_ CL W z f/) M O N Q O W FIRE PROTECTION ENGINEER: FIRE ALARM CONTRACTOR: SHANER LIFE SAFETY THUL ELECTRONICS SHEET DESCRIPTION: PO BOX 1073 PO BOX 534 FRISCO, CO 80443 AVON, CO 81620 FIRE ALARM PLAN PHONE: 970-409-9082 PHONE: 970-949-4638 FAX: 970-797-1898 FAX: 970-949-1928 DRAWN BY: DATE: DLS 10/22/14 SHEET#: FA-00