Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A14-0073_A14-0073 detector specs_1415298000.pdf
Vigilant Catalog ► Intelligent Initiating /G/LAN T TM Fire & Life Safety c ,-;r• - — Intelligent I' r 0 • Detectors and Bases Detectors: V-PS, V-PHS, V-HFD, V-HRD Bases: B4U, RB4U, IB4U, SB4U -- Overview Edwards Vigilant brand intelligent analog detectors are meticu- Standard Features lously engineered to deliver high-performance features, superb reliability, and unbeatable quality.With their highly stable design, • Optical, heat, and multisensor models available these detectors resist air movement caused by heating and air • Compatible standard, relay, isolator,and audible bases conditioning, making them reliable performers ideally suited to modern building interiors. • Field replaceable optical chamber The installation and maintenance advantages of Vigilant brand • Electronic Addressing including mapping location intelligent detectors add value throughout their service life.The • Bases mount to standard North American two-gang or 4" twist-and-lock design makes short work of installation and main- square electrical boxes tenance operations.A plastic breakout on the detector housing • Dual color LED provides at a glance alarm indication optionally prevents removal from the base except with a special tool. • Tamper-resistant feature A bright, easy-to-see LED flashes red when the detector is in • Self diagnostic capability with on-board storage of results alarm,thus eliminating much of the guesswork when responding • Optical detectors feature automatic rate compensated sensitiv- to front-panel indications. ity adjustment, as well as dirty sensor warnings • The V-HFD is fixed-temperature heat detector with an alarm • Manufactured to strict international ISO 9001 standards threshold of 135° F(57°C). • The V-HRD is a rate-of-rise heat detector calibrated for 15°F • Assembled using surface mount technology for RF resistance (8°C)per minute. • Conformally coated components resist dust and humidity • The V-PHS houses an optical sensing chamber that detects • Automatic detector test smoke, as well as a fixed-temperature sensor that detects heat.The detector analyzes data from both sensors to deter- • Low Profile Design mine when an alarm is initiated. • The V-PS houses an optical sensing chamber that detects smoke. All detectors feature comprehensive self-diagnostic capability. V-PS and V-PHS optical detectors continuously adjust their sen- sitivity to compensate for changes in the environment such as the presence of dirt, smoke,temperature, and humidity.These detec- tors issue a dirty sensor warning when they reach their preset limit. Pagel of 6 DATA SHEET M85001-0592 Not to be used for installation purposes. Issue 1.2 Heat Detectors Detector Bases / The V-Series heat detectors are capable of performing compre- rzki 0 hensive self-diagnostics and storing the results. �! r Thanks to advanced thermistor technology,V-Series heat detectors /..,.,' are ideal for sensing fast,flaming fires and for applications where I . \ _ smoke detection is inappropriate.They are particularly well-suited � � to areas such as kitchens and shower rooms,where the ambient / �N�� temperature is relatively constant,but where steam and smoke are •% �11 present. ,,...))\\',J Compatible V-HRD Rate-of-Rise Heat Detector provides a 15°F(8°C)per \ ' electrical box minute rate-of-rise heat sensor for the detection of heat due to fire. AIIMIk The heat sensor monitors the temperature of the air and deter- – Base plate mines whether an alarm should be initiated. 6-32 ) 1 screws V-HFD Fixed Temperature Heat Detector provides a 135°F(57°C) Gasket fixed-temperature heat sensor for the detection of heat due to fire. The heat sensor monitors the temperature of the air and deter- Trim ring mines whether an alarm should be initiated. Detector Optical and combination detectors Connect the detector to the base by rotating the detector clock- V-Series optical detectors continuously adjust their sensitivity wise until it snaps into the locked position. based on fluctuating environmental conditions such as the pres- ence of dirt, smoke, humidity, or changes in temperature, and The head can be removed by turning it counterclockwise. notifies the panel of any changes in sensor sensitivity.When the ® o If the head must lock to the base, break away the detector has adjusted its sensitivity to its maximum limit, it issues a dirty sensor warning, allowing enough of a margin for maintenance locking tab shown below using a pair of pliers. personnel to clean the detector before it goes into trouble condi- 11 To then remove the detector head, insert a small tion. - i screwdriver into the slot on the side of the base These detectors perform comprehensive self-diagnostics and and press in while simultaneously turning the store these details in their on-board memory. Breakaway tab detector head counterclockwise. V-PHS Optical/Fixed Temperature Detector houses an optical sensing chamber that detects smoke, as well as a fixed-temper- ature sensor that detects heat.The detector analyzes data from B4U Standard Base both sensors to determine when an alarm is initiated.This com The B4U Analog Standard Detector Base features twist-and-lock bines the suitability of optical sensing for slow burning fires with detector installation and is compatible with with V-Series analog the sensitivity of fixed-temperature detection for fast flaming fires detectors.The base does not require a separate address because to arrive at a solution that responds reliably to the widest range of it shares the address of the device it is connected to. fire types. Remote LED Maximum resistance A sophisticated algorithm processes data from both sensors over - per wire time so that an alarm is only reported when conditions precisely ®CID must not • exceed match the signature of a fire.This eliminates the shortcomings of Ohms single-sensor optical and heat detection,and significantly reducesFm the risk of nuisance alarms. controllerrfl1O _.°�I a V-PS Optical Smoke Detector uses an optical sensing chamber to detect smoke.The detector analyzes datagathered bythe sen- previous O\;i� ,' 0 Toe nexte Y device II �� device sor to determine when an alarm is initiated. SLC in( `�� SLC out(-) Thanks to its high-performance optical sensing chamber,the V-PS SLC in(+ SLC out(+) responds quickly and reliably to a wide range of fire types, espe- Term Description Term Description cially slow burning fires fuelled by combustibles typically found 1 SLC in and SLC out(+) 4 Not used in modern multi-use buildings.The V-PS detects extremely small 2 SLC in(-) 5 Remote LED(+) particles and triggers an alarm at the first sign of smoke. 3 Not used 6 SLC out(-) 3 Not used 6 Remote LED(-) LED Indication V-Series detectors provide a bicolor status LED: • Normal: Green LED flashes • Alarm/active: Red LED flashes Page 2 of 6 DATA SHEM85001-0592 Not to be used for installa oses. Issue 1.2 IB4U Isolator Detector Base SB4U Audible(Sounder) Detector Base The IB4U Analog Isolator Detector Base is designed to prevent The SB4U is designed to add an audible output function to corn- an entire communications loop from being disabled when a short patible detectors.The base can operate as an independent local circuit occurs.This is accomplished by isolating the part of the alarm, or as part of a zone or system alarm with synchronized loop containing the short from the remainder of the circuit.These audible output. bases automatically restore the entire loop when the cause of the Depending on the system supporting the device loop,the base short circuit is corrected. can operate as follows: SLCSLC in . SLC out in(jam • SII;out(+) • It can follow the state of the device it supports From To next • It can be controlled and configured for other operating modes controller O device or through programming. rough e pr '/ I ` 4 The SB4U is field-configurable for output tone(steady or temporal) TB2 1' ; °� I" and output volume(low dBA or high dBA).The base must be con- Wo ® - nected to a continuous voltage whether the output tone is set to ® ®*f 0 `o °,, : steady or temporal.The base does not require a separate address � •o because it shares the address of the device it is connected to. Term Description 2 3 SLC in(+) DATA+(IN) _ SLC in(-) DATA-(IN) 0 iii® —U— SLC out(+) DATA+(OUT) ' SLC out(-) DATA-(OUT) o 8 Oe, cal !IMIEE AUX_RISER+ A AIM= A gUX_RISER+ RB4U Relay Detector Base AUX_RISERgyM il�.E , AUX_RISER- SLC+ i- ; SLC+ The RB4U Analog Relay Detector Base is designed to add relay SLC- functionality to the listed compatible detectors. Form C latching SLc relay contacts are included for the control of appliances such as 0 door closers,fans, dampers, etc. 1. AUX-RISER IN(from power supply or previous base) SIC in(-)> ► SIC out(-) 2. Volume setting:default is high volume;cut per item 4 for low volume SIC in(+)) • SIC out(+) From 3. Tone setting:default is temporal pattern;cut per item 4 for steady tone To next controller 4 Ndevice 4. To configure output volume or tone,cut the circuit board as shown or 5. AUX_RISER OUT To next base or EOL relay previous /fAlp Q 6. SLC OUT to next intelligent addressable device device '7Ll" TB2 to j 7. SLC IN from intelligent addressable controller or previous device N �: w�� ' I . TB1 ,1' Sleeping rooms: In sleeping areas,the high dBA output and tem- p poral tone settings must be used. However, if the FACP is produc- ing the three-tone temporal evacuation signal,then the high dBA /O and steadytone settings maybe used. N/O COM N/C output g Term Description Term Description AB4G-SB:When using the AB4G-SB box, N/O(Normally open) SLC in(-) DATA-(IN) COM(Common) SLC out(+) DATA+(OUT) install a reinforcing plate at every knockout TB1 N/C(Normally DATA (OUT) used. (Reinforcing plates are included with "�-111r,--- Closed) SLC out(-) the box.) Remove the knockout first,then Contact rating: slide the reinforcing plate into the plastic SLC in(+) DATA+(IN) 2.0a 30vdc resistive housing.After the plate is in place, install the conduit connector and nut. Notes 1. Wire in accordance with NFPA 70,National Electrical Code. 2. Be sure to observe the polarity of the terminals on the terminal block as shown in the diagram. 3. Break wire run at each terminal.Do not loop signaling circuit field wires around terminals. Page 3 of 6 DATA SHEET M85001-0592 Not to be used for installation purposes. Issue 1.2 Specifications, SB4U Audible Detector Base Operating current in mA(RMS) Operating voltage 24 VDC or 24 VFWR,nominal Voltage Low dBA High dBA Operating current See Table 1 16 VDC 17 28 Supervisory current DC=1.46 mA,FWR=2.15 mA 24 VDC 24 41 Default settings 33 VDC 31 52 Output volume High dBA 16 VFWR 41 48 Output tone Temporal pattern 24 VFWR 51 60 Sound level output See Table 2 33 VFWR 60 66 Temporal pattern 0.5 s on,0.5 s off,0.5 s on,0.5 s off,0.5 s on, VDC=Volts direct current,regulated and filtered 1.5 s off,repeat cycle VFWR=Volts full wave rectified Operating environment Temperature 32 to 120°F(0 to 49°C) Sound level output(dBA) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Storage temperature -4 to 140°F(-20 to 60°C) Signal Voltage Low dBA High dBA Compatible V-PS,V-PHS,V-HRD,and V-HFD detectors Reverberant room per UL 464[1] detectors 16 VDC 71.3 77.2 Compatible electrical North American 2-1/2 in.(64 mm)deep 2 gang Temporal 24 VDC 75.0 79.8 boxes box 33 VDC 77.7 81.5 Standard 4"square box 1-1/2 in.(38 mm)deep 16 VDC 75.8 80.5 box Steady 24 VDC 79.2 84.1 European 100 mm square box 33 VDC 82.0 86.0 Wire size 12, 14, 16,or 18 AWG wire(2.5, 1.5, 1.0, Reverberant room per UL 268[2] or 0.75 sq.mm) (Sizes 16 and 18 AWG are preferred) 16 VDC 77.3 83.2 Base diameter 6.0 in.(152 mm) Temporal 24 VDC 81.0 85.8 Height from box 2.58 in.(66 mm) 33 VDC 83.7 87.5 (including detector) 16 VDC 81.8 86.5 Maximum distance 12 in.(305 mm) Steady 24 VDC 85.2 90.1 from ceiling(wall 33 VDC 88.0 92.0 mount) dBA=Decibels,A-weighted [1]For UL 464 applications,low dBA settings are for private mode only [2]For UL268 applications,high setting must be used for evacuation Specifications, Detectors V-PHS V-PS V-HRD V-HFD Air velocity 0 to 5,000 ft/min(0 to 25.39 m/s) N/A Smoke sensitivity range 0.67%-3.66% ULI fixed-temp alarm rating 135°F(57°C) N/A 135°F(57°C) ULC fixed-temp alarm rating 140°F(60°C) 140°F(60°C) Maximum Spacing 30 ft(9.1 m) 50 ft(15 m)centers Rate-of-Rise N/A 15°F(8°C)/min. N/A Operating voltage 15.2 to 19.95 VDC Normal operating current 45 pA,average Alarm current 45 pA,average Environmental compensation Automatic Compatible bases B4U Standard,RB4U Relay,IB4U Isolator,SB4U Audible Maximum distance from ceiling wall-mounted 12 in(305 mm) Storage temperature -4 to 140°F(-20 to 60°C) Operating environment Temperature:32 to 120°F(0 to 49°C);Humidity:0 to 93%RH,noncondensing at 90°F(32°C) Meets UL 268, Meets UL 268, Agency listings ULC-S529-02,UL 521, ULC-S529-02,NFPA 72, Meets UL 521,ULC-S530-M91,NFPA 72,and ULC-S530-M91, NFPA 72, and CAN/ULC S524-01 CAN/ULC S524-01 and CAN/ULC S524-01 Page 4 of 6 DATA SHEM85001-0592 Not to be used for installa oses. Issue 1.2 Specifications, Bases B4U Standard Base IB4U Isolator Detector Base RB4U Relay Detector Base Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Storage temperature range -4 to 140°F(-20 to 60°C) Compatible detectors V-PS,V-PHS,V-HRD,and V-HFD detectors Compatible electrical boxes North American 2-1/2 in.(64 mm)deep 2 gang box Standard 4 in.square box 1-1/2 in.(38 mm)deep box European 100 mm square box Wire size 12, 14, 16,or 18 AWG wire(2.5, 1.5, 1.0,or 0.75 sq.mm) (Sizes 16 and 18 AWG are preferred) Base diameter 6.0 in.(152 mm) Height from box(including detector) 2.08 in.(53 mm) 2.57 in.(65 mm) Maximum distance from ceiling(wall 12 in.(305 mm) mount) Ordering Information Model Description Ship Wt.:lb.(kg) V-PHS Intelligent Analog Optical/Fixed Temperature Detector 0.25(0.11) V-PS Intelligent Analog Optical Smoke Detector 0.25(0.11) V-HRD Intelligent Analog Rate-of-Rise Heat Detector 0.25(0.11) V-HFD Intelligent Analog Fixed Temperature Heat Detector 0.25(0.11) B4U Standard Base 0.11 (0.05) RB4U Relay Detector Base 0.11 (0.05) IB4U Isolator Detector Base 0.11 (0.05) SB4U Audible(Sounder)Detector Base 0.11 (0.05) AB4G-SB Surface Box for Audible Base 1.0(0.45) RLED Remote alarm LED,use with standard base only 0.2(.09) 211-10PKG Replacement optical chambers(package of 10) 0.25(0.11) Page 5 of 6 DATA SHEET M85001-0592 Not to be used for installation purposes. Issue 1.2 WARDS A UTC Fire&Security Company Detection&alarm since 1872 U.S. T 888 244 9979 F 866 503 3996 Canada T 705 875 2659 F 705 944 8861 Southeast Asia T:+65 6391 9300 F:+65 6391 9306 India T:+91 80 4344 2000 F:+91 80 4344 2050 Europe T+32 2 725 11 20 F+32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 utcfi rean dsec u rity.c om ©2010 UTC Fire&Security. All rights reserved. 0 Page 6 of 6 DATA S H E M85001-0592 Not to be used for installa oses. Issue 1.2