Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A14-0073_Manual Pull Station specs_1415298000.pdf
Vigilant Catalog ► Intelligent Initiating /G/LAN T TM Fire & Life Safety .1 Manual Pull PULL_ iN OF SE Stations ARE GSA-M270, GSA-M270P, PuuFOR GSA-M278 FIRE MEA Patented GSA-M270 SERIES Overview • Break glass operation The GSA M270 and GSA M278 series Manual Pull Stations are An up-front visible glass rod on the GSA-M270 discourages part of Vigilant's Signature Series system.The GSA-M270 Fire tampering. Alarm Manual Pull Stations feature our very familiar teardrop • Intelligent device with integral microprocessor shape.They are made from die-cast zinc and finished with red All decisions are made at the station allowing lower com- epoxy powder-coat paint complemented by aluminum colored munication speed while substantially improving control panel stripes and markings. With positive pull-lever operation, one pull response time. Less sensitive to line noise and loop wiring on the station handle breaks the glass rod and turns in a posi- properties;twisted or shielded wire is not required. tive alarm, ensuring protection plus fool-proof operation. Presignal • ADA Compliant models(GSA-M270P)are equipped with a general alarm(GA) Meets ADA requirements for manual pull stations. keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is • Electronic Addressing with Non-volatile memory not required for proper operation. Permanently stores programmable address, serial number, type of device, and job number.Automatically updates historic Vigilant's double action single stage GSA-M278 station is a con- information including hours of operation, last maintenance temporary style manual station made from durable red colored date, number of alarms and troubles, and time and date of last lexan. To initiate an alarm,first lift the upper door marked"LIFT alarm. THEN PULL HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling GSA-M270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. GSA-M270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action GSA-M278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 DATA SHEET M85001-0279 Not to be used for installation purposes. Issue 8 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm2) mined by their sub-type code or"Personality Code". NORMALLY- to#12 AWG(2.5mm2)wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory; no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con- ARefer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REAR VIEW of 278 Signature Series manual stations are compatible only with Vigi- lant's Signature Loop Controller. p T82 I I� Warnings & Cautions 8 7 This device will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further (Al rm ActItive) o o GLED (NNoror mal) safeguards with your local fire protection specialist. 3 2 ' 0 TB,10 U►®®N ° IC:I Testing & Maintenance �■I■� To test(or reset)the station simply open the station and operate DATA IN(+) ' DATA OUT WI the exposed switch.The GSA-M270 series are opened with a tool; 1 DATA IN(-) , DATA OUT(-) the GSA-M278 requires the key which is supplied with that station. From Signature Controller To Next Device or Previous Device 0 The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily,from the control panel.Availability of maintenance dependent on the fire alarm system used. REAR VIEW features is y of Scheduled maintenance(Regular or Selected)for proper system 270P,270PB operation should be planned to meet the requirements of the o Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and �o ° ULC CAN/ULC 536 standards. TB2 �� I► l� 8 7 6 5 Red LED Green LED (Alarm/Active) I n 3 2 (Normal) TB] • O p I SII C (DATA IN(+) DATA OUT WI 1 l DATA IN(-) • DATA OUT(-) From Signature Controller To Next Device or Previous Device 0 Figure 5. Two Stage Systems Page 2 of 4 DATA s I M85001-0279 Not to be used for installation purposes. Issue 8 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch(38 mm)deep 4-inch square boxes with 1-gang, t/-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13; in Canada, use Iberville Model Cl- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Edwards recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box OM Compatible Electrical Box -Cover Release A. Cover t�r� \ j 11 Release �Ici "11 , Screw �^ PFRM ' Al)LA A I! 00 KHAN ' �i ` ` WO rl 1 Q O i ° Back \ ff0 IP- ° Back Q Plate ' O Plate ILITo le o° S it h Switch I" 51 .tdri Is) Glass RodGlass Rod Release Lever \ Villih:11„ OPEN G Figure 1. GSA-M278 installation Figure 2. GSA-M270, SIMGC-270F,SIMGC-270B installation Cover Release Scr-w O4-Compatible • Electrical Box roilwith' inch4,01raisedCovers 4 E5 V agiL i I r,,,,,..- Back o �. Plate ►t l�� 'I Toggle ' ` ° Switch NORMA 0 o p • / �� Glass Rod Release Lever Do not use �L, boxes with rounded N • openings. O Figure 3. GSA-M270P,SIMGC-270PB installation Page 3 of 4 DATA SHEET M85001-0279 Not to be used for installation purposes. Issue 8 Specifications TOWARDS GSA-,SIM SIMGC- GSA-M270P, Catalog Number 270F,SIMGC 2706 SIMGC-270PB GSA-M278 A UTC Fire&Security Company Single Action Single Action-Two Double Action Description -One Stage Stage(Presignal) -One Stage Detection&alarm since 1872 Addressing Uses 1 Module Uses 2 Module Uses 1 Module u.S. Requirements Address Addresses Address T 888 244 9979 Standby=250pA Standby=396pA Standby=250pA F 866-503-3996 Operating Current Activated=400pA Activated=680pA Activated=400pA Canada Construction&Finish Diecast Zinc-Red Epoxy Lexan-Red with T 705 875 2659 with aluminum markings white markings F 705 944 8861 Type Code Factory Set Southeast Asia Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) T:+65 6391 9300 Operating Temperature:32°F to 120°F(0°C to 49°C) F:+65 6391 9306 Storage and Operating Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% Environment RH India T:+91 so 4344 2000 On-board Green LED-Flashes when polled F:+91 80 4344 2050 LED Operation On-board Red LED-Flashes w hen in alarm Both LEDs-Glow steady when in alarm(stand-alone) Europe Compatibility Use With:Signature Loop Controller T+32 2 725 11 20 F+32 2 721 86 13 Agency Listings UL,ULC(note 1), MEA,CSFM Note:SIMGC-270F SIMGC-2708 and SIMGC-270PB are ULC listed only.Suffix"F'indicates French markings. Latin America Suffix"8"indicates English/French biting ual markings. T 305 593 4301 F 305 593 4300 utcfireandsecurity.com Ordering Information ©2010 UTC Fire&Security. All rights reserved. Ship Catalog Wt.lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings-UL/ULC Listed SIMGC One Stage Fire Alarm Station, French Markings-ULC Listed 270F SIMGC One Stage Fire Alarm Station,French/English Markings-ULC Listed 270B GSA- Two Stage(Presignal)Fire Alarm Station,English Markings-UL/ULC 1 (0.5) M270P Listed SIMGC- Two Stage(Presignal)Fire Alarm Station,French/English Markings 270PB -ULC Listed GSA M278 Double Action(One Stage)Fire Alarm Station, English Markings -UL/ULC Listed Accessories 32997 GA Key w/Tag-for pre-signal station(CANADA ONLY) 276-K2 GA Key-for pre-signal station (USA ONLY) 276-K1 Station Reset Key, Supplied with all Key Reset Stations 0.1 (.05) 27165 12 Glass Rods-for GSA-M270 series(CANADA ONLY) 270-GLR 20 Glass Rods-for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods-for GSA-M278 series 276B-RSB Surface Mount Box,Red-for SIGA pull stations 1 (0.6) a rn Page 4 of 4 DATA M85001-0279 Not to be used for installation purposes. Issue 8