HomeMy WebLinkAboutA15-0012_Area of Refuge Command Center_1446057600.pdf -------••----4.,
. , AREA-OF-REFUGE
TH
AREA-OF-REFUGE
www.....Aw.�•m _ COMMAND CENTER
16721 1.6.C.8
i- Command Center Cabinet
(Surface Mount) Command Center
System includes: Cabinet, Phone& (Desk Mount)
Termination Module
• 2500-16RC(Up to 16 Zones) &COMIMANDCENTER
Size: 12"W x 15.12" H x 6.125" 0 I'
• 2500-56RC(Up to 56 Zones)
Size: 20.3"W x 21.07"H x 5.125"D i=it 13:16 -7
I el) N --- i • 2500-112RC(Up to 112 Zones) ;-
Size: Same as 2500-56RC .m . °--
-° Command Center Cabinet
(Flush Mount) '
System includes: Cabinet, Phone&
. NMI COMM CEMER
Termination Module
7.•-_,. " ,* • 2500-16RCF(Up to 16 Zones) IOW'
j , Front Cover: 14"W x 16.11" H x 3" D System includes Phone&Termination Module
Back Box: 12" H x 15.625"W x 3.06" D • 2500-16NC(Up to 16 Zones)
• 2500-16NC(Up to 56 Zones)
• 2500-56RCF(Up to 56 Zones) • 2500-16NC(Up to 112 Zones)
Front Cover: 25"W x 21.11"H x 3"D
Back Cover: 23"W x 20.64"H x 3"D Note: Expandable to larger systems
• 2500-112RCF(Up to 112 Zones)
Command Center Cabinet: Size: Same as 2500-56RCF
• Surface or flush mount cabinet (
• Powder coated steel enclosure with twist lock closure. Termination ,
Will accept Fireman's lock (not provided by Rath) Module i .
• Single pair back to Termination Module -'
Model Number: ' • + ,.
• Works with either our model 2100 series (up to 10 call Termination Module I
boxes/ zone) or our 2400 series (one call box/ zone) Size: 5-3/4"H x 7"W x 10"D L. 1
Surface Mount I
• Powered from Termination Module (only 2400 series) / f•
• Audible alert sounds when Call Box(es) place a call until t 4/
Command Center joins conversation
• Calls wait in queue until previous call is disconnected Module:
• LED's indicate which Call Box(es) have initiated a call • Install on a wall or table top
• Rescue personnel can communicate with individual • Requires 120vac power with battery back up
Call Box(es) and also outside party or Rath RP7700104 power supply with
• IBC, NFPA and ADAAG code compliant battery back up
• 3 year warranty • Single dedicated phone line
For larger projects, contact us
N56 W24720 N. Corporate Circle • Sussex, WI 53089
04/12 800-451-1460 • 262-246-4828 (fax) • e
www.area-of-refug .com Made in the USA
www.area-of-refuge.com Year Warranty
. TH AREA-OF-REFUGE
F•REF
AREA•O [FGE
w�.. . ..t�
REFUGE POWER SUPPLY
__ 16721 1 .6.C.7
l �r''✓
stis
Imo6•
•
ELIck,u
'fl o
• Model Number: RP7700104
• Dimensions: 9.8" x 3.9" x 15"
• Power Supply with Battery Back-up
• 1000VA/600 W
• Underwriters Laboratory Recognized (UL 1778)
• Visual & Audible Alarms
• 120vac
• Sealed, lead-acid, maintenance free battery
• LCD Screen gives utility & battery back-up status
• Battery back-up & surge protected outlets keep Refuge Command Center and Refuge Call Boxes
running when the power goes out during an emergency
N56 W24720 N. Corporate Circle • Sussex, WI 53089
Made in the USA
09/12 800-451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com 3Year Warranty
• AREA-OF-REFUGE
N POWER SUPPLY
16721 1.6.C.7
4
• Model: 2500-PWR24
• Size: 9.275" x 8.125" x 3.75"
• Shipping Weight: 11 lbs.
• 24vdc, 9 Outputs. Install up to (5) phones per output
• 4 Amp (100VA) Supply Current
• Integral Surge Protection
• Underwriters Laboratory Recognized
• Individual LED power Indication
TH
AREA-OF-REFUGE
N56 W24720 N. Corporate Circle • Sussex, WI 53089
-^^°•���'� °•m 800-451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com 02/13
_________nr____
AREA-OF-REFUGE
A ` ' TH
AREA-OF-REFUGE CALL BOXES
4 � rif # 4 �RTH 4 r)
" ' " ' 16721 1.6.C.2 " ' .
HELP PHONE HELP PHONE HELP PHONE
•wu„UGHi:[AUHYG
.4,—.LI...F[.I. .,IMSII.F LIGHG.ECM. BUNMI O LIGHT e[�Ivm
• ) • i •
4 ] 4
Model Number: 2100-956S_(D or R) Model Number: 2100-956SRM_(D or R) Model Number: 2100-956R_(D or R)
Size: 4-3/4”W x 7-1/4" H x 1-7/8" D Size: 4-3/4"W x 7-1/4" H x 1-7/8" D Size: 4-3/4"W x 7-1/4" H x 1-7/8" D
Standard: Stainless Steel, Surface Mount Standard: Stainless Steel, Surface Mount Standard: Red, Powder Coated,
Options: Power, Strobe Interface& Relay Mushroom Push Button Surface Mount
Options: Power, Strobe Interface&Relay Options: Power, Strobe Interface& Relay
Mushroom Push Button Mushroom Push Button
• •
HELP PHONE 1 rc l
•• .IINIMG LIGHT fi£I. • 01.1111 •
HELP PHONE
EMERGENCY PHONE -=-.:`
PUSH FOR HELP
STH
n _._.... E• c r
Model Number: 2100-956B_(D or R) Model Number: 2100-984L_(D or R) Model Number: 2100-958S_(D or R)
Size: 4-3/4"W x 7-1/4" H x 1-7/8" D Size: 6"W x 9-1/2" H x 2-7/8" D Plate Size: 9-3/4"W x 12-1/2" H x 3" D
Standard: Black Call Box Standard: Red, Nema 4X Back Box: 6"W x 8" H x 3" D
Options: Power, Strobe Interface & Relay Options: Power, Strobe Interface&Relay Standard: Brushed Stainless Steel,
Mushroom Push Button Mushroom Push Button Flush Mount
Options: Power, Strobe Interface& Relay
Mushroom Push Button
Model: 2500-PWR24(Power Supply)
Size: 9.275"x 8.125"x 3.75"
Shipping Weight: 11 lbs.
24vdc, 9 Outputs. Install up to(5) phones per output
4 Amp (100VA)Supply Current
Integral Surge Protection
Underwriters Laboratory Recognized
Individual LED power Indication
OATI Individual PTC Output Protection
N56 W24720 N. Corporate Circle • Sussex, WI 53089
in the USA
05/12 800-451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com Made Year inarranty
• AREA-OF-REFUGE
N CALL BOXES
16721 1.6.C.8
► Rath Microtech General Features:
•ADA compliant speaker phones (Meets all requirements of IBC, ADAAG and NFPA)
• Requires analog telephone line either POTS, PBX or central office phone lines. If used on a digital
system, you must purchase an ATA analog telephone adaptor from Rath Microtech or the digital
provider. Make sure to have them program it with a standard wink or disconnect signal per FCC and
CRTC requirements
• 3 year warranty
• Battery back-up (Allows for 4 hours of full operation upon loss of power)
• Power Requirements: Local 120vac power or Low Voltage 24vac power
(Phone suffix D=local 120vac or R=remote 24vac). Remote power requires model 2500-PWR24
• Built-in 10 phone consolidator feature allows you to install 10 Call Boxes on one telephone line
• Programmable with up to 5 emergency numbers
• On-site or remote programming
• Pictorial keypad
• Remote or on-site diagnostic test
• Location Message (18 second recordable message)
• Phone checks every 24 hours for an active phone line, if one is not detected, phone will provide a
relay trip
• Compatible with SmartRescue Base Stations for in-building rescue coordination
• Temperature range -40°F to +150°F
•Automatic dialer (31 digit programmable memory)
• Programming error indicator
• Fully automated operation. No special codes or procedures to remember
•Automatic answer feature
•Audible ring
• LED: 2vdc, 1/3 watt (Lights when phone is activated and flashes when call is received)
• Touch Tone operation only (Touch Tone is an AT&T registered trademark)
• On hook telephone line voltage: 24V-48V (Off hook: 48V=3.55V & 24V=3.59V)
(Most standard telephone lines are 48V & many switchboard/PBX lines are 24V)
• Loop current: (48V=23.89mA and 24V=24.32mA)
• Ringer equivalent number (REN): .5B
• FCC Part 68 Registered
TH
AREA-OF-REFUGE
www DN. nelup•corn
N56 W24720 N. Corporate Circle • Sussex, WI 53089
Made in the USA
04/12 800-451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com 3Year Warranty
____-.... .
AREA-OF-REFUGE
`- � 'T'H
REA•OF-REFUGE SIGNAGE
w w....wr n.e....
•
1
PUSH FOR HELP
LOCATION FLOOR
Persons able to use the exit
‘. . 41/
stairway do so as soon as
possible, unless they are
AREA OF I AREA OF assisting others.
AREA OF REFUGE REFUGE REFUGE After activating
the Area of Refuge
Photo Luminescent*Wall Sign communication system,wait
Model Number: Raise Letter/Braille Entry Way Sign here for assistance.
7041 (8" x 8") Model Number: J
7043 - Black/White (6" x 9")
7044- Blue/White (6" x 9") "Directions for Call Boxes"
Wall Sign (With Braille)
oto 1 (s.
O O F Rk- Model Number: 7049
Size. 6 x 8 - __
t
AREA OF
REFUGE t. AREA OF
. (-)‘• REFUGE
Skid Resistant Floor Decal Braille Photo Luminescent*Wall Sign
Model Number: 7045 Model Number: 7046
Size: 17" D Size: 8"x 8"
120/277 VAC Lighted Wall Sign
Model Number:
AREA OF REFUGE L 7050 (Single Sided) or 7050D (Double Sided)
-411111
EXTERIOR Size: 10.5" H x 14" W x 3" D
AREA FOR Features:
• Power: 120/277 VAC
ASSISTED • Battery Back-up
AREA OF REFUGE RESCUE •• LED Lights
, 6... • Constant Uniform Illumination
• UL Listed to meet UL 924, NEC, OSHA, NFPA &
Life Safety Code Illumination requirements
Directional Sign Exterior Rescue Assistance • White Aluminum Housing With Acrylic Surface
Model Numbers:7047L(left arrow) Wall Sign • Voltage Surge & Short Circuit Protection
7047R (right arrow) Model Number: 7086 • Directional Arrows Available Upon Request
Size: 15" x 5" Size: 8"x 8" 16721 1.6.C.8
N56 W24720 N. Corporate Circle • Sussex, WI 53089
Made in the USA
03/13 800-451-1460 • 262-246-4828 (fax) • www.area-of-refuge.com 3 Year Warranty