Loading...
HomeMy WebLinkAboutA15-0012_Audio and Telephone Masters_1446057660.pdf EST Catalog►EST3 Life Safety Platform T-----sT TM 16721 1.6.C.2 Life Safety & Communications Audio and4 ` p . . . . . . . Telephone1 -. . t. ...e�.,. ,...e�: J co Masters �E 3-ASU series o Overview Standard Features The efficient EST3 audio system provides for intuitive local and • Eight channels for audio source selection remote audio control for Mass Notification/Emergency Com • Audio data to remote EST3 panels with amplifiers can be munications(MNEC), Life Safety and other approved uses. EST3 transmitted over twisted copper wires or fiber optic cables(see audio builds from standard modules that fit together easily.Audio Data Sheet 85010-0131 for details on EST3 fiber optic corn- components use standard EST3 cabinets and power supplies. munications) Taking full advantage of digital technology, up to eight channels • Listed for Mass Notification/Emergency Communications of audio sources transmit over a single twisted pair of wires or fiber optic cables between nodes.Coupling the inherent reliability • UL2572 as CCS or ACU or LOC. and performance of zoned amplifiers with EST3 simplified user • Auxiliary audio input interface for campus paging,telephone interfaces makes audio system design and operation easy and interface,etc. dependable. • Single fiber optic filament or one twisted pair of wires between The 3-ASU is seamlessly integrated into an EST3 system to pro- nodes vide for a rugged and reliable communications package that can be configured for Mass Notification/Emergency Communication • VU display shows paging output level (MNEC), as well as fire alarm and other emergency functions.The • Ready-to-page LED 3-ASU audio source unit supports eight channels of clear digital • audio that is easily distributed to panels containing 3-ZA rail ampli Digital transmission of audio signals - fiers.The 3-ASU supports digital storage and playback of pre- greater noise immunity recorded messages as well as live paging.The optional 3-FTCU - high quality signal transmission provides a unique, space-saving and easy-to-operate control point • On board storage of programmed messages and tones for dedicated emergency/firefighter two-way telephones. • Optional LCD display of fire phone calls • Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page 1 of 4 DATA SHEET 85010-0063 Not to be used for installation purposes. Issue 11 Application All Call Minus selects all amplifiers not programmed for alarm signaling for page delivery(typically stairwells). EST3 audio is accomplished by selecting modular components for installation in standard fire alarm cabinet assemblies.At the main Page by Phone selects the telephone voice line as the paging control panel location mounting audio control equipment provides source. an emergency user interface for"Paging"and optionally a"Fire Operating the Microphone Talk Key stops alarm signaling to se- fighters Master Telephone".Zoned amplifiers mount in the main lected zones and starts pre announce tone delivery. control panel and/or in remote nodes. By mounting amplifiers in remote nodes,wire runs and space requirements are reduced at When the pre-announce tone finishes,the Ready to Page LED turns the main control panel. on. The heart of the EST3 audio package is the Audio Source Unit When system design calls for paging with Firefighters telephone (ASU).The Audio Source unit converts analog signals to digital the 3-ASU/FT provides all the paging features of the 3-ASU series signals. On board audio memory stores signal tones and/or alarm- with the added benefit of a master handset assembly.The 3-ASU/ alert verbal messages. FT brings to the emergency user easy to understand switches These digitally stored messages can be recorded onsite using and text messages displaying on a backlit 8 x 20 character LCD standard PC audio components or downloaded from a library display. of pre-recorded messages and tones. Messages can be in any language or combination of languages.The ASU comes standard with two minutes of memory for tone and message storage.Avail Firefighters telephone able message memory expands easily to 100 minutes with the CONNECT switch selects phone optional 3-ASUMX/100 memory expansion card. circuits shown in the Calls Pending Audio Source units support connection of a local microphone, ' F= ,' -u-,' U Window. remote microphone,telephone voice line, and Mass Notification/ oa;, E„,.� REVIEW PENDING stops auto- Emergency Communication(MNEC)audio feed.With eight audio matic display of pending calls and channels to choose from combinations of paging,alert, evacuation -o, allows the operator to step through signaling and automatic messages are available for simultaneous ( 1 each message at his own pace. delivery to different parts of a building or to different buildings. 5. ° ACK(acknowledge)silences the There are two main audio user interface modules:the paging P.1. telephone systems audible signal. microphone, and the firefighter's telephone,which supports three- The signal resounds for any new state and four-state firefighter telephones.Available individually or call. in a set, EST3 audio modules open system design possibilities. DISCONNECT disconnects the highlighted call in the calls con- When the Life Safety system requires paging only the 3-ASU or nected list. 3-ASU/4 Audio Source Units provides a Master Paging micro- phone with common controls. Switch labeling makes the opera- REVIEW CONNECTED scrolls a reverse highlight through the tion intuitive. Six LEDs and five switches cover paging operations. calls connected list. Three of the five paging switches,All Call, Page to Evacuation, and Page to Alert, cover most paging operations.A VU display shows the user the output level of the page in process.The 3-ASU 0 CALLS PENDING The Firefighters telephone LCD is very series mount in one chassis space of a EST3 Lobby enclosure. similar to the 3-LCD. When there is no In addition to the paging microphone the 3-ASU/4 has mounting E A E R G E N C S TELEPHONE active telephone calls the LCD shows space for up to four local rail modules, including 20,40,and 95 a title screen.Active calls display a text watt zone amplifiers and up to four Control Display modules allow- message referenc-ing the remote ing layout flexibility. The 3-ASU provides the same functionality as UNIT. OK phone location. the 3-ASU/4 but is supplied with an inner door filler plate and no , CR L L S PENDING local rail module spaces. FIRST S R S E PI n Ec CONNECTED V LEVEL When a remote handset is lifted the LCD display updates to show the calls pending and the call-in signal sounds to alert the user of a pending call. Paging Microphone D C R L L S PENDING The user answers the call by press- If Ready-to-Page LED turns on after the CALLS CORRECTED I �: 0 = pre announce tone has finished indicating the FIRST B R S E N E N T LEVEL ing the Connect switch. The location message moves from the pending system is ready to page. line to the connected line.The call in .. .I Erol I 400.01 All Call selects all amplifiers for page signal silences.The user simply uses hlll. 1 delivery. CR L L S PENDING the master telephone to talk with the iENGINEERING OFFICE connected telephone. 1471 01 I CRLLS CONNECTED PagetoEVAC selects allamplifiers cur i FIRST BRSEIOENT LEVEL EL I,MGs If another call comes in the location 1.11=11 rently delivering evacuation signaling for message appears in the calls pending delivery. line and audible signal resounds.The ',,,j ... ,, Page to ALERT selects all amplifiers user can silence the signal by answer- currently delivering alert signaling for page ing the call or by pressing the ACK(acknowledge)switch. delivery. Up to five remote telephone handset assemblies connect to the system simultaneously without any degradation of audio quality. Page 2 of 4 DATA Si.,, , 85010-0063 Not to be used for installation purposes. Issue 11 Installation and Mounting Typical Wiring Typical Fire Fighters Telephone Circuit ULI/ULC Listed I®I' 47K ohm EOL Resistor _1 i V - I� Twisted Shielded Pair �I 0 `- if run with other wiring Sr;I O. roan 111,..2.1O'.^^I= e Z rl�l rm`ZaZaZZaZ�Z�`�`7�7s7 —.-==--11-. To SI nature ir�1 I I Data Circuit r1°n I!II!I�II!III I!I!I!I 1 T Phones �® GI1I1Is 111111:Jr■1=1 InL�f - • --f, - �® - NC C NO NO C NIA NC NO C NC1 I aCu .es TROUBLE ALARM SUP e z, Connect to T61 on 3-CPU3 Module 1 I .a a I 3-ASU/4 has Chassis,Audio Source Unit, To next panel MAIN PROCESSOR MODULE I To Signature Paging Common Control and rail space 3-CPU Module 3-CPU3 1 I Data Circuit for four Local Rail Modules. Mounts in + + W i► Telephone Riser Twisted Shielded Pair lobby enclosure. p° ii cc ,Ameeeeeeeeee - Connect Shield to 0 1 I =Earth Ground only 1111111 I I I at the panel. Maintain ::: shield continuity. [i}••• 'moi 'a '°' V u a z�_iiIJ I I Dashed Wires Required J +p -.° o ■=•■ �1 for Class'A'Wiring Only •== Audio Source Unit I Audio Fire <:% z I + 3-ASU r Source Phone RAIL --3-ASUFT • Card Card CARD •O ¢ +- Control Panel From previous panel • 3-CPU Module Mass Notification •• Key-Out • J' 10 • 3-REMICA ICA e �` or .p ® Audio Out 3-3REMICP ��� � I (Shielded) • o- To CPU Module • • 'a ❑_ TB2-Audio A IN y MI MN-FVPN or AUX ttl Input(1V)for Remote /i'� / Paging from UL listed - r compatible Fire or MNEC 00000000000000 system. 3-ASU/FT has Chassis Assembly/w 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Audio Source Unit, Paging Common ASU TB1 Audio Data Telephone Page Remote Mic—\ Aux Control and Fire Phone Controls Primary Secondary Out Key Audio Engineering Specification The audio system shall provide eight simultaneous and distinct System amplifiers must be distributed zoned type. Centrally banked audio channels.These shall consist of a minimum of: Local Page, systems are not acceptable.The circuit must carry a minimum rating Emergency Communication, Multiple Evacuation,Alert,Auxiliary, of 3.5 Amps for operating 24 Vdc signals. and General Signaling.Channels shall support hierarchical opera- The system shall provide fully integrated fire fighters'telephone tion and be controllable from system programming.The audio system that shall provide 2-way communication between the fire system also provides Elevator, Stairwell and Auxiliary signaling. alarm control panel and any fire fighters'telephone station. «The Systems that cause signaling devices to go silent while performing Audio Source Unit and Firefighters Telephone shall be installed so any signaling functions will not be accepted. that a seismic component Importance Factor of 1.5 is achieved.» The system must provide operation to 25Vrms or 70.7Vrms speak- The system shall include an alphanumeric user display and controls. ers. The system must provide as a minimum the following paging When a telephone is activated,a call-in buzzer shall sound,and the common controls and indicators: Ready to page LED,VU display of location of the phone shall be shown on the alphanumeric display. paging output level,single switch function for paging to all —Alert The display shall be capable of bilingual operation,displaying Eng- zones,Evacuation zones,and areas not programmed for signaling. lish, Dutch, Finnish, French,German, Italian, Portuguese or Spanish The system must provide high quality analog to digital conversion messages. of paging sources. Digital transmission of paging must be provided The incoming call shall be selected by activating a single button.All between system nodes.The analog sources must be sampled and subsequent telephone call locations shall be displayed in full text. converted to digital with a sampling rate no less than 9600 samples The system shall display all incoming calls,all connected phone(s) per second. It must be possible to transmit signal sources(Alert, on the alphanumeric display.The system shall be configured so that Alarm, Page,etc.)together over a single pair of wires between nodes. page messages may be issued from any firefighter's telephone con- nected to the system,as directed by the emergency operator. Page 3 of 4 DATA SHEET 85010-0063 Not to be used for installation purposes. Issue 11 Specifications TOWARDS Catalog 3-ASU 3-ASU/4 3-ASU/FT 3-FTCU Number A UTC Fire&Security Company Agency Listings UL,ULC,CE Detection&alarm since 1872 Ambient Temp. 0°C-49°C(32°F-120°F) Ambient Humidity 93%Non-condensing @ 32°C u.S. Mounting One Chassis Space T 888-378-2329 Network Data Riser-18-12AWG F 866-503-3996 (1.0-2.5mm2)(3-ASU/FT only) Canada Network Data Riser-One pair twisted Chubb Edwards 18-12AWG(1.0mm2-2.5mm2) Network Audio Riser-18-12AWG T 519 376 2430 Wire Size (1.0-2.5mm2)(3-ASU/FT only) F 519 376 7258 Network Audio Riser-One pair twisted 18-12AWG(1.0mm2-2.5mm2) Telephone Riser-One pair twisted Southeast Asia shielded 18-14 AWG T:+65 6391 9300 (1.0mm2 to 1.5mm2) F:+65 6391 9306 112 mA 32 mA Current Rating 80 mA in Alarm and Supervisory Supervisory and Supervisory and India Alarm Alarm T:+91 80 4344 2000 F:+91 80 4344 2050 Local Microphone(isolated and Local microphone(isolated and supervised);Remote Microphone supervised);Remote microphone Australia Audio Inputs (isolated and supervised); (isolated and supervised);Firefighters' T+61 3 9239 1200 OneMNEC audioinput. telephone(isolated and supervised; F+61 392391299One MNEC audio input. Europe Pre-recorded Two minutes standard expandable to 100 minutes T+32 2 725 11 20 Message Storage with optional 3-ASUMX/100.Max.message length 40 N/A F+32 2 721 86 13 seconds. Supported 255 N/A Latin America Message Count T 305 593 4301 Auxiliary Input F 305 593 4300 impedance 1K Ohm N/A utcfireandsecurity.com Bilingual Support English, Dutch,Finnish, French,German,Italian,Portuguese,Spanish ©2010 UTC Fire&Security. Telephone Riser All rights reserved. Active N/A Five Maximum Telephones Wire size vN/A One pair twisted shielded 18-14 AWG (1.0mm2 tol.5mm2) Line Resistance N/A 50 Ohm EOL Resistance N/A 15K Ohm Ordering Information Catalog Ship Number Description Wt.lb. (kg) 3-ASU/FT' Audio Source Unit with Local Microphone and Firefighters Telephone. 20(9.1) 3-ASU/4 Audio Source Unit w/Local Microphone.Provides four local rail spaces. 15(6.8) 3-ASU' Audio Source Unit w/Local Microphone. Inner door filler plate 15(6.8) 3-FTCU' Firefighters Telephone Control Unit inner door filler plate. 15(6.8) 3 ASUMX/100 Audio Source Unit Memory Expansion.Provides 100 minutes of 0.5(.23) message time. 3-FTEQ Seismic hardening kit for 3-ASU/FT or 3-FTCU telephone handset 2 RFK1 Ferrite Clamp Kit required for EN-54 compliance .25(.11) 3-LKE UK English Label Kit .25(.11) 3-LKF French Label Kit .25(.11) 3-LKR Russian Label Kit .25(.11) 3-LKS Spanish Label Kit .25(.11) 1.Add"-CC"for City of Chicago 2.For earthquake anchorage,including detailed mounting weights and center of gravity detail,please refer to Seismic Application Guide 3101676.Approval of panel anchorage to site structure may require local AHJ, structural,or civil engineer review. 0 Page 4 of 4 DATA S 85010-0063 Not to be used for installation purposes. Issue 11