HomeMy WebLinkAboutA15-0012_Central Processor Unit_1446057660.pdf EST Catalog►EST3 Life Safety Platform Er-- -----sT TM 16721 1.6.C.1 )IIIPILife Safety & Communications EST3 Central . V!3I Processor Un �t _._ r , '',::, = = 0 3-CPU3, 3-RS485A, 3-RS485B, 3-RS232 f:. ......... — .,, 1 (E - EN54-2:1997+A1 and EN54- 4:1997+A1:2002+A2 ! '71111, -_ pending. r. . Overview Standard Features The 3-CPU3 is the Central Processing Unit Module monitoring the • Up to 1,000 history events status of all modules and providing the link for network commu • RS 485 local rail communications nications.Although each local rail card contains their own micro- processor,the 3-CPU3 provides all inter-module communication • Multiplexed audio channels and has the ability to download rail module operating parameters. • Network communication media can consist of twisted copper Upon power up the 3-CPU3 automatically learns all local rail module RS485, short-haul modems and/or single or multimode fiber attributes and locations.Site specific software is loaded into the optic cables 3-CPU3 which then downloads data to each local rail module. Firmware upgrades are also done from the 3-CPU3 eliminating the • RS-232 communication card need to unplug chips on rail modules. • Form 'C'contacts for:Alarm, Supervisory and Trouble Mounting must be in the first two local rail spaces of the upper • Low voltage memory write protection 3-CHAS7(module chassis). Options for the 3-CPU3 include the addition of an LCD display and User Interface, RS-232 Communi- • Non-volatile memory cation Card,and RS-485 Series Network Communication Cards. The 3-CPU3 is fully compatible on the same network with the 3-CPU and 3-CPU1 modules. Pagel of 4 DATA SHEL 85010-0133 Not to be used for installation purposes. Issue 6 Application Installation and Mounting The 3-CPU3 helps make EST3 an extremely powerful and flexible • ® • system.As a single node, stand alone system a single 3-CPU3 controls 1 to 19 additional local rail modules. For larger systems, _ Q _ up to 64 nodes interconnect on a peer-to-peer multi-priority token _ II II ® ring protocol network. Supply I Supply The 3-CPU3 controls all local panel responses to automatic, user initiated, or network reported events.As a network node, it is an -• 1•1•1••••••1 Ilddeldeld0 Ilddddd•IMI W666666661 equal among peers,there is no master on the network.This gives O Central exceptional response times over the network, less than three Processor seconds. \ Unit Module Each 3-CPU3 provides slots at the back for mounting Network, 13-CPU3 and RS-232, cards. Removable terminal blocks on the 3-CPU3 • support connection of network and audio data wiring.On board common relays also terminate at the 3-CPU3 terminals.To aid Data in trouble shooting and service, status LEDs monitor local rail, Maximum resistance between any 3 panels 90 Ohms network, RS232 and audio data communications. Maximum capacitance between any 3 panels 0.3 pF The Network Communications card mounts to the back of the Maximum distance between any 3 panels 5,000 ft.(1,524 m) Central Processor Unit.The 3-RS485A card provides a Class A via RS485 (Style 7)or Class B(Style 4)circuit for network communications signals and support for a Class B(Style 4)or Class A(Style 7- Capacitance,enulati network Maximumncemum Accumulative Capacitance dual Style 4)circuit for the digitized audio signals.The 3-RS485B card provides a Class B(Style 4)or Class A(Style 7)circuit for Wire Size 38.4K Baud 19.2K Baud network communications signals and a second Class B(Style 4) 18 AWG 1.4 pF 2.8 pF circuit for the digitized audio signals. Network messages received 16 AWG 1.8 pF 3.6 pF by the Network Communications card are re-transmitted to the 14 AWG 2.1 pF 4.2 NF next network node. Re-transmission maximizes the wire run lengths between nodes.With 64 nodes miles of network length is Audio possible. Fail safe mechanisms built into the card direct connect Maximum resistance between any 3 panels 90 Ohms the data input and output ports should the network card or its Maximum capacitance between any 3 panels 0.09 pF related Central Processor fail. Network communications may be Maximum distance between any 3 panels 5,000 ft.(1,524 m) configured via copper or fiber media using the 3-FIBMB. via copper RS485 The 3-RS232 Communication Card mounts to the back of the 3-CPU3.The 3-RS232 has two optically isolated RS-232 ports. The ports support connection of a printer and/or an external com- mand center. Entire network downloading from one location(to all 64 nodes)is available through the RS-232 card. Engineering Specification It must be possible to support a single stand alone node or up to 64 nodes communicating on a peer-to-peer token ring proto- col network. Network and digitized audio wiring shall be run in a [choose one: Class A(Style 7)or Class B(Style 4)]configuration. Network alarm response from alarm input to signal activation must be under 3 seconds. All field wiring must be to removable terminal blocks. Status LEDs must be provided for communications of net- work and internal rail communications. Inter-node communication speed must be programmable. Internal rail communications speed must be programmable. Page 2 of 4 DATA SHEET 85010-0133 Not to be used for installation purposes. Issue 6 Typical Wiring To external supervisory input circuit To external alarmr input circuit[ To external troubler input circuitL kJILIJH RnPPPPlimr1 Notes 0 0 0 o=b o o o=b o 1. Maximum#14 AWG(1.5 mm2)wire; ®®®®®®®®®® minimum#18 AWG(0.75 mm2). N N NC C NO NO C N/A NC NO C NC C-0 TROUBLE ALARM SUP 2. All shields,if used,must be continuous Cc o n2 c Connect to TB1 on 3-CPU3 Module and insulated from ground,except at the c6 originating panel. c^ >^ 3. Class A network data requires one pair E j CENTRAL of wires connecting the last node to the LU oU ,a PROCESSING first node. 1 c5 ILM Q o UNIT MODULE 4. Class A audio data requires two pairs +_ 4_1 I+_I Y Q of wires running in opposite directions, NN AA No V 3 U, originating at the node containing the Z) _as Connect to TB2 on 3-CPU3 Module ASU. Z U 000000000000000000000 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 /1R�/ III/III IIt- DB9 FEMALE I 11 (REAR VIEW) In PIN 9 (5)COM �� • (3)Tx. 1 PORT#2(isolated) - (2)RXD I• TO PRINTER OR REMOTE a tPINI COMMAND SYSTEM, IIORo ai a Z DB25 FEMALE Y 9 LL (REAR VIEW) oZ a a PIN 13 PIN 25 Ii z i---c -) Th—Network Audio Riser PORT#2(isolated) (7)COM COMMAND PRINTER <W�Class A only W ^^ (3) XD (2)TXD PIN 14 O= TD M D PIN 13 PIN 25 O COU DB25 FEMALE •5�Q Q Q o (REAR VIEW) 2�r> �c� PORT#1 02-.503 cCOM ISOLATED PORT 0 O (7) TO PRINTER OR REMOTE E0_ a52 COMMAND SYSTEM. 20 LL M QCT') (3)RXD _ (2)TXD I— a) I-,— PIN 14 Cj PIN 1 cts Q D_ 0 M Page 3 of 4 DATA S H E L , 85010-0133 Not to be used for installation purposes. Issue 6 Specifications WAR OS 3-CPU3 Agency Listings UL,ULC,CSFM,CE,LPCB EN54"pending. A UTC Fire&Security Company Mounting 2-Left most local rail spaces Detection&alarm since 1872 Terminal Size 18-12 AWG(1.0mm2 to 2.5mm2) Standby Current 155 mA u.S. Alarm Current 165 mA T 888-378-2329 Contact Ratings Nonbypassable Alarm,Supervisory and Trouble Form'C' 1 A at 30 Vdc F 866-503-3996 Data Down Loading RJ14 Jack Canada Operating Environment 0°C-49°C(32°F-120°F);93%at 40°C Non-Condensing Chubb Edwards "EN54-2:1997+A1 and EN54-4:1997+A1:2002+A2 pending T 519 376 2430 Note:CPU current includes the main power supply,since the CPU and PPS cannot be measured F 519 376 7258 separately. Southeast Asia T:+65 6391 9300 Option Cards F:+65 6391 9306 Catalog number 3-RS232 3-RS485A 3-RS485B India Standby Current 58 mA 98 mA 98 mA T:+91 80 4344 2000 Alarm Current 58 mA 98 mA 98 mA F:+91 80 4344 2050 One Class B(Style 4) Australia Two optically isolated Three RS-485 Class A or Class A(Style 7) T+61 3 9239 1200 Communication Ports RS 232 (Style 7) network data circuit F+61 3 9239 1299 and one Class B(Style 4)audio data circuit Europe Agency Listings UL,ULC.CSFM,CE,LPCB.EN54 pending*. T+32 2 725 11 20 Mounting Back of 3-CPU3 F+32 2 721 86 13 Operating Environment 0°C-49°C(32°F-120°F);93%at 40°C Non-Condensing Latin America *EN54-2:1997+A1 and EN54-4:1997+A1:2002+A2 pending T 305 593 4301 F 305 593 4300 utcfi reandsecu rity.com Ordering Information ©2010 UTC Fire&Security. All rights reserved. Catalog Ship Wt. Number Description lb(kg) 3-CPU3 Central Processor Unit Module 0.71b(0.32kg) 3-RS485A Network Communications Card,Class A(Style 7) 0.331b (0.15kg) 3-RS485B One Class NB network data circuit and one Class B audio data 0.331b circuit (0.15kg) 3-RS232 RS-232 Communication Card 0.331b (0.15kg) 3 CPUDR CPU doors with filler plates. Order separately,one required per CPU 0.25Ib where no LCD display is installed. (0.11 kg) a 9 Page 4 of 4 DATA SHEET 85010-0133 Not to be used for installation purposes. Issue 6