Loading...
HomeMy WebLinkAboutA15-0012_Conduit, Hardware, Fittings, Tape, Labels_1446057660.pdf Prime 0 nduit, Inc. 16721 1.6.C.4 Schedule 40 PVC Rigid Nonmetallic Conduit �� 6„, • ETL Listed to UL651 in compliance with the NEC • Heavy Wall EPC • Listed for underground applications encased in concrete or direct burial. • Also for use in exposed or concealed applications aboveground. • Sunlight resistant • Rated for use with 90°C conductors • Superior weathering characteristics • Made in USA Part Number Trade Std. Crate Qty. Wt. Per Dimensions *With Integral Bell 10' 20' Size 10' 20' 100' O.D. I.D. Wall 49005-010 - 1/2" 6000' - 17 0.840 0.622 0.109 49007-010 49007-020 3/4 4400' 8800' 23 1.050 0.824 0.113 I 49008-010 49008-020 1" 3600' 7200' 34 1.315 1.049 0.133 49009-010 49009-020 11/4" 3300' 6600' 46 1.660 1.380 0.140 49010-010 49010-020 1 11/2" 2250' 4500' 55 1.900 1.610 0.145 49011-010 49011-020 2" 1400' 2800' 73 2.375 2.067 0.154 } 49012-010 49012-020 21/2" 930' 1860' 124 2.875 2.469 0.203 49013-010 49013-020 3" 880' 1760' 163 3.500 3.068 0.216 49014-010 49014-020 31/2" 630' 1260' 196 4.000 3.548 0.226 49015-010 49015-020 4" 570' 1140' 232 4.500 4.026 0.237 49016-010 49016-020 5" 380' 760' 315 5.563 5.047 0.258 49017-010 49017-020 6" 260' 520' 409 6.625 6.065 0.280 Notes: 1. Rigid nonmetallic conduit is normally supplied in standard 10' lengths, with one belled end per length. For specific requirements, it may be produced in lengths shorter or longer than 10', with or without belled ends 2. Special conduit sizes will be quoted on request. 3. DON'T FORGET TO ORDER CEMENT. 4. Use RNC Fittings with Schedule 40 and Schedule 80 Conduit 5. Prime Conduit reserves the right to ship to the nearest unitized quantity. 23240 Chagrin Blvd Suite 405•Cleveland,OH 44122.216-464-3400•www.primeconduit.com 2 16 KRALOY PVC ELECTRICAL FITTINGS CONDUIT FITTINGS 16721 1.6.C.4 Couplings Size Part Product N Min (in.) OD OL (in.) Number Code (in.) (in.) 1/2 CP05 078001 0.055 1.062 1.410 3/4 CP07 078002 0.070 1.265 1.535 1 CP10 078003 0.095 1.545 1.860 1 1/4 CP12 078004 0.110 1.945 2.020 1 1/2 CP15 078005 0.084 2.180 2.255 2 CP20 078006 0.095 2.683 2.390 2-1/2 CP25 078007 0.170 3.240 3.120 � OD 7 3 CP30 078008 0.166 3.940 3.340 3-1/2 CP35 078009 0.200 4.480 3.615 51 g III 4 CP40 078010 0.225 5.000 3.765 OL N 1 5 CP50 078012 0.270 6.120 4.170 g = 6 CP60 078014 0.255 7.285 4.875 8 CP80 178192 - - - 52 Coupling = x B ize Part Product L (in.) (i Number Code 2 5EC20 078049 4.0 3 5EC30 0780 6.0 4 5EC40 0 :053 7.0 �_, 5 5EC50 078055 7.5 6 5' 60 078422 11.0 52 Couplings B x S co 0 z Size Part Product (in. Number Code L(in.) ii i- 5EC2OBS 078025 4.0 m o 3 5EC3OBS 078026 6.0 z 0U 4 5EC4OBS 078028 • 0 L ..,.„,,..,. 6 5EC6OBS 078030 11.0 ----- L ----- KRALOY PVC ELECTRICAL FITTINGS 17 16721 1.6.C.4 Long Line Couplings Size Part Product 'n.) Number Code L(in.) D M. (in.) 2 LLC20 078063 3.675 2.399 2-1/2 LLC25 078065 4.28 2.897 3 LLC30 078066 4.80 3.523 4 .LC40 078067 6 0 4.524 Li 5 LL '0 078068 8.22 5.603 6 LLC60 078069 8.22 6.669 ID 1 I- L ,I Repair Coupling SIe- es Size Part Product L(in.) • Min (in.) D Max(in.) (in.) Num.-r Code 1-1/2 "C15 077292 2.300 .•12 1.924 2 REC20 078617 2.405 2.36 2.399 2-1/2 REC25 078041 3.450 2.883 2.897 REC30 078042 3.600 3.507 3.523 4 REC40 078044 3.920 4.506 4. 4 D 5 REC50 078619 4.275 5.583 5.603 6 REC60 077298 4.620 6.647 6.669 - L -1 Terminal Adapters Size Part Product OL(in.) TL Min (in.) (in.) Number Code 1/2 TA05 078084 1.305 0.550 3/4 TA07 078085 1.435 0.565 1 TA10 078086 1.775 0.800 1-1/4 TA12 078087 1.855 0.800 0 O 1-1/2 TA15 078088 1.980 0.800 Z v 2 TA20 078089 2.070 0.810 c 2-1/2 TA25 078090 2.480 0.820 3 TA30 078091 2.580 0.765G_I z 3-1/2 TA35 078092 2.815 0.920 5)N 4 TA40 078093 2.870 0.870OPPOPOIMI. 5 TA50 078094 3.710 1.390 TL 6 TA60 078095 3.540 1.080 +� DL _ F 8 TA80 178190 - - 18 KRALOY PVC ELECTRICAL FITTINGS CONDUIT FITTINGS 16721 1.6.C.4 Female Adapters 111.7 Size Part Product OL(in.) TL Min (in.) (in.) Number Code 1/2 FA05 078070 1.400 0.700 3/4 FA07 078071 1.550 0.765 1 FA10 078072 2.000 1.000 1-1/4 FA12 078073 2.065 1.000 1-1/2 FA15 078074 2.185 1.000 2 FA20 078075 2.260 1.000 2-1/2 FA25 078076 2.290 1.000 3 FA30 078077 2.950 1.145 OL 3-1/2 FA35 078078 4.100 1. 4 FA40 078079 3.120 1.800150 r 5 FA50 078080 3.750 1.520 6 FA60 078081 4.062 1.500 8 FA80 178189 - - Reducer Bushin•- Size Part Produc (in.) Number Co. 3 , x 1/2 MR0705 8 8353 1 x MR1005 078354 At 1 x 3/4 MR1007 078355 1-1/4 x 3/4 MR1207 078356 111. 1-1/4 x 1 MR1210 078357 1-1/2 x 1 MR1510 078359 1-1/2 x 1-1/4 MR1 078360 2 x 1 `2010 078361 2 x 1-1/4 MR2. 2 078363 2 x 1-1/2 MR2015 078362 Cl) O 2-1/2 x 2 MR2520 078364 z F 3 x 2 MR3020 078365 T. H 3 x 2-1/2 MR3025 078366 m O 4 x MR4020 078369 z O , x 3 MR4030 c 8367 C.) 4 x 3-1/2 MR4035 078 .8 Rigid Nonmetallic Conduit - Con 1 16721 1.6.C.4 Fittin s LISTED®°S Cou lin s (7 pansion E33447 LISTED (For se with Schedule 40 &80 Conduit) E32447 Standard Couplings Except where noted by► E945 s:ries expansion fittings are designed to compen'.te for length changes due to temperature All socket fittings should be attached Using Carlon variations 'n exposed conduit runs. solvent cement. Using Carlon fittings with Carlon O.D. nonmetallic conduit insures system integrity. Er A •EXCLUSIVE \folded in Mid-point •Male terminal Adapter d design - -11 indicator on t'• piston. (1/2"-2" NPT Threads and •EXCLUSIVE 2" ' pansion Fitting 21/2"-6" NPSC Thr•:ds). Socket type for f t with an 8" trave +istance. •Two 0-Rings to prey'nt leakage. joining nonmetallic I C �e--\ •Two-piece molded ,esign with •Can be installed v• ically or conduit. L 'i - 1 lubricated seals for•.sier move- horizontally. I...J°..1 ment for the life of the product. •Ridges on the fitting fo easier Std. installation(Sizes 2" thr. gh Part Ctn. A B c L 6° only). No. Size Qty. Typical I.D. O.D. Typical E940D 1/2 150 .852 .836 .728 17/64 11/16 11/2 • • E940E 3/4 100 1.064 1.046 .840 15/16 3/4 15/8 E940F 1 50 1.330 1.310 1.210 15/8 15/16 2 ....--' J r" E940G 11/4 30 1.677 1.655 1.535 163/64 1 21/8 II • Male terminal E940H 11/2 25 1.918 1.894 1.755 215/6a 11/8 23/s Coupling end adapter end E9401 2 30 2.393 2.369 2.190 247/64 13/16 21/2 E940K 21/2 20 2.890 2.868 2.688 35/16 133/64 33/16 Coupling Male Terminal Travel E940K-CAR 21/2 4 2.890 2.868 2.688 35/16 133/64 33/16 End Adapter End d. Length E940L 3 25 3.515 3.492 3.375 331/32 13/4 313/32 Part No. Part No. Size C . sty. (in.) E940L-CAR 3 5 3.515 3.492 3.375 331/32 13/4 313/32 E945D E945DX 1/2 20 4" E940M 31/2 20 4.015 3.992 3.780 49/16 13/4 35/s E945E E945EX 3/4 15 4" E945E E945EX 1 10 4" E940N 4 15 4.515 4.491 4.265 53/32 125/32 33/4 E945G E945GX 11/4 5 4" E940N-CAR 4 5 4.515 4.491 4.265 53/32 125/32 33/4 E945H E945HX 11/ 5 4" E940P 5 8 5.593 5.553 5.097 61/4 15/16 41/16 E9451 E9451X L 15 E940R 6 5 6.658 6.614 6.115 71/2 23/16 45/8 E945K E945KX 11/2 10 8 E945L E945LX 3 10 8" E945M E945MX A31/2 5 8" s ecial Long Line Couplings E945N E945NX A4 5 8" Std. Std.Ctn. E945P E945PX 5 1 8" Y Part No. Size Ctn.Qty. Wt.(lbs.) E945R E945R 6 1 8" E941H 11/2 40 9 E9411 2 25 . E941K 21/2 15 8 E941L 3 15 14 C 0 US Long Line '41N 4 1. 15 Short pansion Couplings E S 447 Couplings E9. PF 5 4 12 (Expands to . maximum of 2") Std. ►E94111' = 5 21 Part No. Size Ctn.Qty. E955D 1/2 40 Fabricated Ex I % sio ' Couplings i .1_ • • 1•L. E955E 3/4 40 41ni ;r. E955F 1 25 I (2) E955G 11/4 15 - • LISTED E955H 11/2 10 E33447 Std. Travel E9551 2 6 P. Ctn. Length No. A Size Qty. (in.) E94 v.L 21/2 10 12 174 www.carlon .com Gross Automation (877) 268-3700 • www.carlonsales.com • sales@grossautomation.com Rigid Nonmetallic Conduit - Adapters 16721 1.6.C.4 O Couplings Adapters LISTED E32447 Special Long Line Couplings- Female Adapters Except where noted by 0- Sleeve Sleeve Couplings = 1 -; i r°- I For adapting nonmetallic ' Sleeve Coupling(For Repair Work) conduits to threaded I f \.B 4 No Internal Stop fittings,metallic systems. �i___ Female threads on one end, Std. St..Ctn. socket end on other. Par No. Size Ctn.Qty. W'.(lbs.) A -.Jj ►E9-:H 11/2 25 6 -f0D ►E94: 2 255 Part Std. A B Min. Max. C T L ►E948 21/2 25A 16 _No. Size Ctn.Qty. Typical D OD Typical 10-E948L 3 25 13 E942D 1/2 150 .852 .836 .620 17/64 11/16 3/4 19/16 ►E948N 4 10 8 E942E 3/4 100 1.064 1.046 .822 15/16 13/16 3/4 15/8 E942F 1 50 1.330 1.310 1.046 15/8 15/16 7/8 115/16 ►E948P 5 14 33 E942G 11/4 30 1.677 1.655 1.377 163/64 1 2/8 2 0-E948R 6 6 16 E942H 11/2 25 1.918 1.894 1.607 25/32 11/8 7/8 27/32_ ►E9481R " (6" long) 1 8 E9421 2 30 2.393 2.369 2.064 247/64 13/16 1 25/16 ►E948.15 " (Sch.40 Split Duct) 5 6 E942K 21/2 20 2.890 2.868 2.450 311/32 15/8 11/8 215/16 0-E948L12 3' (12" long) 1 1 E942K-CAR 21/2 4 2.890 2.868 2.450 311/32 15/8 11/8 215/16 E942L 3 25 3.515 3.492 3.000 331/32 13/4 11/8 31/16 ►E948L6 3" ." long) 15 15 E942L-CAR 3 3 3.515 3.492 3.000 331/32 13/4 11/8 31/16_ ►E948LS 3" (S .40 Split Duct) 25 17 E942M 31/2 20 4.015 3.992 3.500 41/2 17/8 11/8 31/4 _ ►E948N12 4" (12 long) 10 28 E942N 4 15 4.515 4.491 4.000 51/64 2 11/8 313/64 ►E948N7 4" (7" lolg) 15 25 E942N-CAR 4 7 4.515 4.491 4.000 51/64 2 11/8 313/64 ►E948NS 4" (Sch.41 Split Duct) 10 15 E942NX9* 4 15 (Call for information) ►E948PS 5" (Sch.40 slit Duc 1 2 E942P 5 8 5.593 5.553 5.047 61/4 115/16 11/16 33/16 E942R 6 6 6.658 6.614 6.055 71/4 21/8 11/16 33/8 ►E948R10 6" (10" long) 6 25 E942RX* 6 6 (Call for information) ►E948R12 6" (12" long) 6 25 *Long Line Adapter ►E948RS 6" (Sch.40 Split•1uct) 1 2 Special Schedul• 40 , wedge Couplingsr°1 Consult factory for addi onal size• Male Terminal Adapters S For adapting nonmetallic L P.rt No. Size Ctn.Qty. Std.(lbs.) conduits to boxes,threaded E442K 21/z 20 13 ' f fittings,metallic systems. L_______ C • Male threads on one end, { E442R 6 6 27 socket end on other. B 1 ►E442T 8 2 17 L.. Aill -OD----" Risers „,21 Part Std. A B Mi . Max. C S L - No. Size Ctn.Qty. Typical D OD Typical Scheduly 40 �7 lilt - I E943D 1/2 150 .852 .836 .597 11/8 5/8 9/16 15/16 l E943E 3/4 125 1.064 1.046 .800 111137 3/4 9/16 1318 INUM - E943F 1 50 1.330 1.310 1.018 15/8 1 11/16 125/32 s"3110 19436 11/4 SU 1.6// 1.655 1.332 2'/32 1 3/4 1',/16 E943H 11/3 25 1.918 1.894 1.566 25/32 13/16 3/4 21/16 - - P. t A B C Thread S... Std.Ctn.• E9431 2 50 2.393 2.369 2.000 221/37 13/16 3/4 2118 o. Size (Length) (Min.) Size Ctn. ty. Wt.(lbs.)• E943K 21/2 25 2.890 2.868 2.376 35/16 13/4 7/8 27/8 954HX 11/2 80.00 1.567 .950 11/2"NPT 1 , E943K-CAR 21/2 5 2.890 2.868 2.376 35/16 13/4 7/8 2718 E9541 2 60.00 2.024 .825 2"NPT 1 E943L 3 45 3.515 3.492 2.954 4 115/16 7/8 31/16 E954JX 2 80.00 2.024 .825 2"NPT 1 . 1 E943L-CAR 3 5 3.515 3.492 2.954 4 115/16 7/8 31/16 E954K 21/2 60.00 2.418 .812 21/2"NPSC 1 6.1 E943M 31/2 30 4.015 3.992 3.440 41/2 22/16 17/8 37/16 E954KX 21/2 80.00 2.418 .812 21/2"NPSC 1 8.4 E943N 4 20 4.515 4.491 3.940 53/37 23/8 7/8 31/2 E943N-CAR 4 20 4.515 4.491 3.940 53/32 23/8 7/8 31/2 E954L 3 60.00 3.012 .798 3"NPSC 1 8.7 E943P 5 5 5.593 5.553 4.815 61/4 21/3 1 315/16 E954LX 3 80.00 3.012 .798 3"NPSC 1 11.0 E943R 6 10 6.658 6.614 5.860 71/2 23/8 1 33/8 www.carlon . com 175 Gross Automation (877) 268-3700 • www.carlonsales.com • sales@grossautomation.com Rigid Nonmetallic Conduit — Fittings & Accessories 16721 1.6.C.4 (20 Washers , leeves LISTED p /�TM ExceptE32447 Flat Sealing Washer H' FORLVl , ere noted by 10- Where Where a waterproof termination is required into any Conc -te Sleeves enclosure (metallic or nonmetallic), install the neoprene HOLFORM no etallic concrete washer over the threads of a terminal adapter before sleeve forms are e easy way to inserting into the enclosure. Use a standard locknut or form holes in concr• They threaded bushing to secure the assembly. install in seconds with •.ils, Part No. Size Std.Ctn.Qty. screws or staples and are :.s' ►E943DW 1/20 125 removed.Concrete will no adhere to them. HOLFO' S ar• ►E943EW 3/4 125 adjustable to any slab ickness. E943FW 1 100 Min. Std. Std. ►E943GW 11/4 50 A O.D. Ctn. Ctn. Part No. A B Qty. Wt.(lbs.) ▪E943HW 11/2 500.E92CSH 11/2 13/4 20 3 ►E9431W 2 25 i3 ►E92CSJ 2 213/32 2 6 4 I 8 ►E92CSL 3 313/32 25 8 E92CSN 4 413/32 18 Lock Nuts si 1 ►E92CSP 5 513132 15 8 B ►E92CSR 6 613/32 12 8 PVC Lock Nut ‘ snduit Bodies 0 Part No. Size Std.Ctn.Qty. ►LT9LD 1/2 1200 T�yp X with r ►LT9LE 3/4 700 Cover O•LT9LF 1 600 4 Four knock-o type socket J openings, 90° se.•cing.Available .- • with 1/2" or 3/4" sb ket outlets. 'ull Elbows Includes cover and g. ket. Acce , '91)Pull Elb s COVER 1. 14 61.481 , r, }� GASKET �, � . {�,, . t.- ket inclue''d. C 4 VI(11 S�w�P Y � e i4„,,,.g !,1:11i _Ni 04 Std. A B C D I/2 PORE910cD Part No. S' e Ctn.Qty.Typical sical Typical Typical 114 -WOOF E990D 1/2 75 .852 .83: 2.187 .718 Part 4. Size Vol.Cu.In. Std.Ctn.Qty. E990D; AR 1/2 25 .852 .836 2. :7 .718 E9 rCD 112 15.16 15 W970CE 314 15.16 15 E9'iE 3/4 50 1.064 1.046 2.531 .781 990ER-CAR 3/4 20 1.064 1.046 2.531 . 1 Su.'lied with 4 stainless steel cover screws.Diameter 41/8"Thickness 1/4". * of designed for use with wiring devices or light fixtures. 178 www.carlon .com Gross Automation (877) 268-3700 • www.carlonsales.com • sales@grossautomation.com TPN Cabond 16721 1.6.C.4 PVC Coated Conduit and Fittings PVC Coated 90° Standard Elbows Calbond PVC coated elbows are available in standard &special radius dimensions and in various degrees as required. All elbows are manufactured from Calbond PVC coated conduit and meet all applicable standards. Features: itirill"11 • Exterior PVC coating thickness is a minimum 0.040" • Interior Urethane coating thickness is a minimum 0.002" • Sizes available are 1/2" to 6" • Available in 90, 60, 45, and 30 degree bends1111 UL listings and Compliances: ~T-. • Calbond PVC coated conduit is UL/CUL listed in accordance to UL6 &ANSI A C80.1 Standards • Calbond PVC coated conduit is UL/CUL listed rigid ferrous metal conduit with polyvinyl chloride coating verified for PVC adhesion performance • Calbond PVC coated conduit complies with NEMA RN-1 • UL File Number E226472 & E230584 H B Size Weight Standard Trade Metric Per 100 Radius Offset Tangent Aluminum Item Number Size (mm) (lbs) A B T Item Number PV0590EL00 1/2" 16 70 4.25 6.0 1.7 PA0590ELO0 IPV0790EL00 3/4" 21 100 4.50 6.7 2.2 PA0790EL00 I PV1090EL00 1" 27 190 5.75 8.0 2.4 PA1090ELO0 PV1290EL00 1-1/4" 35 310 7.25 9.6 2.8 PA1290EL00 PV1590EL00 1-1/2" 41 400 8.25 10.6 2.6 PA1590EL00 PV2090EL00 2" 53 640 9.50 12.0 3.5 PA2090EL00 PV2590EL00 2-1/2" 63 1210 10.50 14.8 4.7 PA2590EL00 PV3090EL00 3" 78 1950 13.00 17.0 5.3 PA3090EL00 PV3590EL00 3-1/2" 91 2630 15.00 20.9 6.1 PA3590EL00 PV4090EL00 4" 103 3280 16.00 21.0 6.5 PA4090EL00 PV5090EL00 5" 129 6750 24.00 32.0 11.2 PA5090EL00 PV6090EL00 6" 155 10510 30.00 41.0 12.1 PA6090EL00 Calbond 923 Calpipe Road, Santa Paula, CA 93060 Ph: (562)803.4388 Fax: (562)803.9883 I calbond.com Ocal PVC-Coated Conduit and Accessories 16721 1.6.C.4 Factory bent to save wasted time and materials! N OCAL-BLUE Standard-Radius Elbows , c • Fabricated from Ocal® PVC-coated conduit 0 • Standard radii in 30°, 45°, 60° and 90° available for immediate shipment c -, • Color-coded thread protectors for easy identification of conduit size y a.) C PIPE SIZE STRAIGHT END UNBENT WEIGHT EACH o CAT.NO. IN. RADIUS"R" OFFSET"C" "D" LENGTH STEEL ONLY C METRIC SIZE IN. IN. IN. IN. LBS. i STEEL ALUMINUM DESIGNATOR* MM MM MM MM KG O ELL1/2-_-_ ELL1/2- -SA- 1/2 4.00 6.00 2.00 10.28 .67 16 101.60 152.40 50.80 261.19 16.95 Ts TU ELL3/4-_-_ ELL3/4-_-SA-_ % 4.50 6.50 2.00 11.07 .95 0 21 114.30 165.10 50.80 281.14 24.07 I ELL1-_-_ ELL1-_-SA-_ 1 5.75 8.00 2.25 13.53 1.77 y 27 146.05 203.20 57.15 343.71 44.97 = ELL11/4-_-_ ELL11/4-_-SA-_ 11/a 7.25 9.50 2.25 15.89 2.55 E 35 184.15 241.30 57.15 403.56 64.80 ii ELL11/2-_-_ ELL11/2-_-SA-_ 1% 8.25 11.00 2.75 18.46 3.98 oa 41 209.55 279.40 69.85 468.86 101.13 ELL2- - ELL2- -SA- 2 9.50 13.00 3.50 21.92 6.33 -0 53 241.30 330.20 88.90 556.83 160.86 0 ELL21/2-_-_ ELL21/2-_-SA-_ 2% 10.50 14.00 3.50 23.49 9.65 C., 63 266.70 355.60 88.90 596.73 245.09 ELL3-_-_ ELL3-_-SA-_ 3 13.00 16.50 3.50 27.42 15.42 78 330.20 419.10 88.90 696.48 391.77 ELL31/2-_-_ ELL31/2-_-SA-_ 3% 15.00 20.75 5.75 35.06 23.30 91 381.00 527.05 146.05 890.57 591.84 ELL4-_-_ ELL4-_-SA-_ 4 16.00 21.75 5.75 36.63 29.68 103 406.40 552.45 146.05 930.47 753.80 ELL5-_-_ ELL5-_-SA-_ 5 24.00 31.00 7.00 51.70 60.82 129 609.60 787.40 177.80 1313.16 1544.89 ELL6-_-_ ELLE-_-SA-_ 6 30.00 39.00 9.00 65.12 85.69 155 762.00 990.60 228.60 1654.15 2176.51 ITEM PIPE SIZE ANGLE MATERIAL COLOR1111111111 1111111111 ELL 3/4- _- _- _ 30=30° Blank=Steel G=Gray ■ I Iliki 45=45° SA=Aluminum W=White 60=60° B=Blue -- D I Blank=90° V =-.-.•i Catalog No.Example: Custom colors also available. < c > ELL3/4SA-W is a 34"trade size 90° aluminum elbow coated in white PVC. United States Technical Services Thomas efts Tel: 901.252.8000 Tel: 888.862.3289 WWw.tnb.com R 14 800.816.7809 Fax:901.252.1354 16721 1.6.C.4 (I% WESTERA TUBE & COADUIT CORPORATIOA vidr0EMT (ELECTRICAL METALLIC TUBING) Including COLOR EMT & CONDUIT KIT Western Tube EMT is made from strip steel, high frequency (ERW) welded. A continuous hot galvanizing process is employed to coat the exterior surfaces evenly and smoothly. A special transparent secondary coating provides further protection against corrosion. Manufactured in accordance with Underwriters Laboratories specification UL-797, American National Standards Institute(ANSI) specification C80.3, and CSA C22.2 No. 83.1. Also conforms to Federal Specifications WW-C-563A, which has been superseded by the UL document. Approved by the National Electric Code article 358, for open, concealed and concrete slab installations. Quality controlled each step of the way - regular tests for weld strength, bendability, plating thickness, all dimensions, and uniform smoothness of interior coating provide you with conduit of the highest quality. Western Tube EMT provides perfect bends and offsets that can be made quickly and easily. Western Tube EMT uses a special polymer ID coating that has low friction so that feeding wires is simple and quick, providing extra ease in wire installation. No chipping, cracking, peeling - outside surfaces are galvanized with zinc coating for superior corrosion resistance and long-lasting, dependable service.A special protective coating is then applied. • Compatible with all types of building materials • Provides a lifetime of safe electrical installations • Low in cost-strong, durable A Conduit Kit consists of a pre-assembled section of EMT with a coupling, as is traditional with Rigid and !MC. It provides a labor-saving and time-saving alternative when assembling long runs of EMT on site. Unlike other integrated coupling products, our steel set-screw and compression coupling Conduit Kits come with the distinct advantage that they allow you to take apart leftover pieces and re-use them as needed. You get both savings and flexibility with every kit. All the components used in our Conduit Kits are UL listed (the couplings are listed to UL 514B), as is the assembly itself(to UL 183). Our conduit products are extremely corrosion resistant and meet all federal and state code requirements. Color EMT is constructed in the same way and meets the same requirements as our standard EMT, and also carries the UL listing and certification. In addition to our standard red, white, blue, green, yellow, orange and black EMT, we are also able to provide custom colors. HOT ZINC COATED CONDUIT SPECIFICATIONS To specify Western Tube Hot Zinc Coated EMT include the following: Electrical Conductors shall be enclosed in Western Tube Hot Zinc Coated EMT in accordance with the National Electrical Code. Electric Metallic Tubing shall be steel, electrically welded, hot zinc galvanized and produced to ANSI Specifications C80.3 and to Underwriters Laboratories specification UL-797, and shall carry the Underwriters Laboratories label, as manufactured by Western Tube and Conduit Corporation. Trade Metric Nominal Nominal Nominal Nominal Feet Qty.in Feet in Nom.Wt. Color Size Designator O.D. I.D. Wall Wt.per in Master Master Per Designator Thickness Foot Sub-Bundle Bundle Bundle Master Bundle Standard EMT and Color EMT Weights and Specifications in. mm in. in. in. lbs. ft. qty. ft. _ lbs. 1/2 16 0.706 0.622 0.042 0.30 100 700 7000 2100 Black 3/4 21 0.922 0.824 0.049 0.46 100 500 5000 2300 Red 1 27 1.163 1.049 0.057 0.67 100 300 3000 2010 Blue 11/4 35 1.510 1.380 0.065 1.01 50 200 2000 2020 Red 11/2 41 1.740 1.610 0.065 1.16 50 150 1500 1740 Black 2 53 2.197 2.067 0.065 1.48 50 120 1200 1776 Blue 21/2 63 2.875 2.731 0.072 2.16 - 61 610 1318 Black 3 78 3.500 3.356 0.072 2.63 - 51 510 1341 Blue 31/2 91 4.000 3.834 0.083 3.49 - 37 370 1291 Black 4 103 4.500 4.334 0.083 3.93 - 30 300 1179 Blue Conduit Kit Weights and Specifications 2 53 2.197 2.067 0.065 1.53 - 52 520 800 21/2 63 2.875 2.731 0.072 2.30 - 33 330 760 3 78 3.500 3.356 0.072 2.82 - 33 330 930 4 91 4.500 4.334 0.083 4.18 - 27 270 1130 August 20I0 F" MADE 16721 1.6.C.4 N U.5 .�- . r An outstanding choice 44 ci - .> _ � when it's important to stand out ..•or to not stand out x .41111111k 111111.1 --- Pi o- Cdor . • Our galvanized Color EMT meets the same requirements as our standard EMT,and also carries the UL listing and certification. Factory testing and controls make sure it bends without kinking or flattening, and that the zinc galvanized layer doesn't crack or flake. A special polymer ID coating that has low friction is used so that feeding wires is simple and easy. And,of course,both the ID and f the OD have uniquely formulated organic coatings that ' ircuits inhibit rust formation. laiake fimportant c . . In addition to our standard red,white, blue,green and stand out immediately black EMT,we are also able to provide custom colors. All the standard colors are stocked in the 3/4"size for quick Iii delivery, and other sizes in any color can also be ordered from our factory. We want to meet your needs. Please 11111. contact our Sales representatives for more information on how we can add color to your project or application. S +c. e e a\e 54 & 40. a4a � ar4, Cca A e ` yae 2. % 4 Mil 40, 4,e, +o'Ck +off . +off dee ct. Qee I co in. in.10 in. in. lbs. ft. qty. ft. lbs. Emergency Systems 1/2 16 0.706 0.622 0.042 03 100 700 7000 2100 Black WM= 3/4 21 0.922 0.824 0.049 0.46 100 500 5000 2300 Red 1 27 1.163 1.049 0.057 0.67 100 300 3000 2010 Blue For Blending in NM 1 1/4 35 1.510 1.380 0.065 1.01 50 200 2000 2020 Red Light Colored Spaces 11/2 41 1.740 1.610 0.065 1.16 50 150 1500 1740 Black 2 53 2.197 2.067 0.065 1.48 50 120 1200 1776 Blue 21/2 63 2.875 2.731 0.072 2.16 - 61 610 1318 Black Data Communications 3 78 3.500 3.356 0.072 2.63 - 51 510 1341 AI 11..1111 31/2 91 4.000 3.834 0.083 3.49 - 37 370 1291 Black For Blending in Dark 4 103 4.500 4.334 0.083 3.93 - 30 300 1179 Blue Colored Spaces Hospital,Healthcare and Critical Care 2001 East Dominguez Street P.O.Box 2720 Long Beach, CA 90801-2720 (800) 310-8823 (310) 537-6300 (714) 952-3188 FAX (310) 604-9785 www.westerntube.com 16721 1.6.C.4 n°allied TUBE & CONDUIT° EMT • Electrical Metallic Tubing and True ColorTM EMT APART OFAatkore E-Z Pull1M EMT Quality Electrical Metallic Tubing • Hot galvanized steel using patented inline Flo-Coat" process ^" -=Y for long lasting exterior protection Y_ ` • E-Z Pull interior coating provides a smooth raceway for fast wire-pulling ry, • Excellent mechanical protection for conductors -,� _ - • Ductility for faster and easier bending +�'"" • Superb EMI shielding characteristics • Trade sizes 1/2 thru 4 True ColorTM EMT Identify Important Circuits Instantly! • All the benefits of E-Z Pull EMT • Instant identification of multiple circuits • Fire Alarm— Red EMT • Healthcare Green EMT • Data Corn Blue EMT • Available in 8 colors • Trade sizes 1/2 thru 4 True ColorTM Applications Black EMT Fire Alarm'"EMT Orange EMT I. _ • Blends in dark • Emergency •• Construction/ colored areas circuits 'l research areas - • 4 ti • Open • Fire alarm and 4 ;24", • Fiber optic systems '^ architecture Security systems •'- • Auto repair/ ` L •Y--- maintenance f- --:rr Yellow EMT Green EMT Blue EMT �� •• High voltage wiring T , •• Hospital and ,�, • Low voltage �` a • Caution areas - healthcare areas 1f3 wiring • - • Special equipment ,,. - - - , • Nurse call stations _ • Data com/video - _ - s� . - • Critical circuits 't.._ - • Network security - Purple EMT mir gWhite EMT Silver EMT - • Specialty wiring 4 �; , 0 • Blends in light • Standard Use systems colored areas • Contemporary W • ': • Security systems I I • Open architecture architecture Project Information Company Name: Address: City: State&Zip: Phone: Project Name: City: State: NOTE:Special orders are non-cancelable,non-returnable and non-refundable. www.alliedeg.com 16721 1.6.C.4 9®allied TUBE & CONDUIT° EMT • Electrical Metallic Tubing and True ColorTM EMT APART O=V\atkore FEATURES&SPECIFICATIONS Manufactured for Long Life Codes &Standards Compliance Allied EMT is precision manufactured from high grade mild Allied EMT is listed to Underwriters Laboratories UL strip steel for exceptional durability and long-lasting life. Allied Safety Standard UL 797 and meets ANSI C80.3. EMT is hot galvanized using Allied's patented in-line Flo-Coat- These standards have been adopted as federal process. This process combines zinc, a conversion coating, specifications in lieu of WWC 563. EMT is recognized as and a clear organic polymer top-coat to form a triple layer of an equipment grounding conductor by NEC Section 250- protection against corrosion and abrasion. 118. Documentation for compliance with NEC Article 250 is also available in the GEMI (Grounding and Electro-Magnetic E-Z Pull* EMT combines strength with ductility, providing easy Interference) analysis software and related research studies bending, cutting and joining while resisting flattening, kinking and found at the www.alliedeg.com website. splitting.Available in trade sizes 1/2-4. Installation of EMT shall be in accordance with the National Coatings Electrical Code and the UL listing information. Allied EMT is Allied Tube& Conduit's standard EMT (Electrical Metallic listed in category FJMX. Master bundles conform to NEMA Tubing) has a special low friction ID coating called E-Z Pull that Standard RN2. greatly improves the slip properties between conduit and wire. With E-Z Pull EMT, wire pulls through the EMT smoothly and Specification Data easily, making installation easier and faster. To specify Allied EMT, include the following: Electrical Metallic Tubing shall be equal to that manufactured by Allied Tube& EMI Shielding Conduit Corporation. EMT shall be hot galvanized steel O.D. with Allied EMT is very effective in reducing electromagnetic an organic corrosion resistant I.D. coating, and shall be listed to field levels for encased power distribution circuits, shielding UL Safety Standard 797 and manufactured in accordance with computers and other sensitive electronic equipment from the ANSI C80.3. effects of electromagnetic interference. For more information on EMT shielding, visit www.alliedeg.com to obtain the GEMI (Grounding and Electro-Magnetic Interference) software analysis program. Electrical Metallic Tubing Weights and Dimensions Trade Metric Approx.Wt.Per Outside Nominal Wall Red and Galvanized All Other Colors** Size Designator 100 Ft.(30.5M) Diameter' Thickness Master Bundle Qty. Master Bundle Qty. lb. kg. in. mm. in. mm. ft. m. ft. m. 1/2 16 30 13.6 0.706 179 0.042 1.07 7000 2135 3500 1067.5 3/4 21 46 20.9 0.922 23.4 0.049 1.25 5000 1525 2500 762.5 _ 1 27 67 30.4 1.163 29.5 0.057 1.45 3000 915 1500* 4575 1-1/4 35 101 45.8 1.510 38.4 0.065 1.65 2000 610 2000 610.0 1-1/2 41 116 52.6 1.740 44.2 0.065 1.65 1500 4575 1500 - 457.5 _ 2 53 148 67.1 2.197 55.8 0.065 1.65 1200 366.0 1200 366.0 2-1/2 63 216 98.0 2.875 73.0 0.072 1.83 610 186.1 610 186.1 3 78 263 119.3 3.500 88.9 0.072 1.83 510 155.6 510 155.6 3-1/2 91 349 158.3 4.000 101.6 0.083 2.11 370 112.9 370 112.9 4 103 393 178.2 4.500 114.3 0.083 2.11 300 91.5 300 91.5 'Outside diameter tolerances:+/-.005 in.(.13mm)for trade sizes 1/2(16mm) *Blue trade size 1 master bundle size:3000 ft/915 m through 2(53mm); **Other Color Trade Sizes 2-4 are available thru special order +/-.010 in.(.25mm)for trade sizes 2-1/2(63mm); +/-.015 in.(.38mm)for trade size 3(78mm); +/-.020 in.(.51 mm)for trade sizes 3-1/2(91 mm)and 4(103mm). NOTE:Length=10 ft.(3.05m)with a tolerance of+/-.25 in.(6.35 mm) 16100 S. Lathrop Ave. Harvey,IL 60426 NOTE:Special orders are non-cancelable,non-returnable and non-refundable. PHONE 708-339-1610•TOLL-FREE 800-882-5543 www.alliedeg.com COLOR CHECK EMT COLORS AND SIZES COLORS 1/z" '/a" 1" 11/4" 11/4" 2" Blue • • • • • • Orange • • • - Red • • • • • • Green • • • - - - *Silver • Black • • • • White - - Yellow Purple • • • - - - *Silver(traditional galvanized EMT)is available from stock B-4.Other colors,sizes and 20'lengths available as special order.Minimum order quantities may apply. COLOR CHECK EMT WEIGHTS AND DIMENSIONS (10' LENGTHS*) METRIC WEIGHT TRADE SIZE DESIGNATOR OF 10 UNIT LENGTHS OUTSIDE DIAMETER INSIDE DIAMETER** WALL THICKNESS** lbs. kg in. mm in. mm in. mm % 16 30 13.6 0.706 17.93 0.622 15.80 .042 1.07 % 21 46 20.9 0.922 23.42 0.824 20.93 .049 1.24 1 27 67 30.4 1.163 29.54 1.049 26.64 .057 1.45 11 35 101 45.8 1.510 38.35 1.380 35.05 .065 1.65 11h 41 116 52.6 1.740 44.20 1.610 40.89 .065 1.65 2 53 148 67.1 2.197 55.80 2.067 52.50 .065 1.65 21 63 216 98.0 2.875 73.03 2.731 69.37 .072 1.83 3 78 263 119.3 3.500 88.90 3.356 85.24 .072 1.83 31 91 349 158.3 4.000 101.60 3.834 97.38 .083 2.11 4 103 393 178.3 4.500 114.30 4.334 110.08 .083 2.11 *Silver(traditional galvanized EMT)is available from stock B-4.Other colors,sizes and 20'lengths available as special order.Minimum order quantities may apply. ""For information only;not a UL-797 requirement. Applicable tolerances:Length:10'(3.05 m)±B"(±6 mm).Outside diameter:B through 2:±0.005"(16 through 53:±0.13 mm),2B:±0.010"(63:±0.25 mm), 3:±0.015"(78:±0.38 mm),3B and 4:±0.020"(91 and 103:±0.5 mm). PACKAGING METRIC BUNDLE QUANTITY/ TRADE SIZE DESIGNATOR TAPE COLOR BUNDLE QUANTITY/LIFT* WEIGHT/LIFT VOLUME/LIFT ft. m Pieces Bundles ft. m lbs. kg cu.ft. cu.m 1% 16 Black 100 30.5 - 70 7000 2134 2100 952.5 31.7 0.9 % 21 Red 100 30.5 - 50 5000 1524 2300 1043.3 36.1 1.0 1 27 Blue 100 30.5 - 30 3000 914 2010 911.7 36.5 1.0 11/a 35 Red 50 15.2 - 40 2000 610 2020 916.3 38.2 1.1 111A 41 Black 50 15.2 - 30 1500 457 1740 789.3 37.9 1.1 2 53 - - - 120 - 1200 366 1776 805.6 46.7 1.3 21% 63 - - - 61 - 610 186 1318 597.8 41.5 1.2 3 78 - - - 51 - 510 155 1341 608.3 48.9 1.4 31% 91 - - - 37 - 370 113 1291 585.6 48.6 1.4 4 103 - - - 30 - 300 91 1179 534.8 50.0 1.4 *The quantity per lift conforms to the National Electrical Manufacturers Association Standards Publication RN-2,Packaging of Master Bundles for Steel Rigid Conduit, Intermediate Metal Conduit(IMC)and Electrical Metallic Tubing(EMT).Pack quantities for Canadian distribution do not comply with NEMA RN-2. STEEL EMT 0 LISTED Wheatland Tube NO.E48675 Jnc STEEL GROUP liral ..__________ _ . _ ..__.7Ili 16721 1.6.C.4 Steel City® .:0,. ..;: /-.4. Thinwall Conduit Fittings (EMT) EM : 1 ectors - Die Cast Zinc Two-Piece Type A -j 90°Angle B-1 C- B--tC Areeit NI B ) E1110 _i ii01.0, A 4% i A Cl PIN EMT Connector CD Set Screw Type Compression Type •y graft TRADE DIMENSIONS I_ STD. T :- DIMENSIONS(IN.) STD. CAT.NO. SIZE(IN.) A B CTN. CAT.NO. TYPE E(IN.) A B C CTN. Pall TC-201M 1/, 1.68 1.05 1,000 TC921 Set Screw Type / 27 1.15 .45 200 UL File No.E16592. TC-911-SC Compression Type 1/2 1.37 .45 200 -7 TC-912-SC Compression Type 5/4 1.86 .95 . ' 200 n s. One-Hole Snap Straps - Steel o-Hole EMT Straps - i Cl) • Steel # B S •el - Malleable Insulated • Zinc plated I I • Steel B ^� • Zinc •.ted A n___!__ Cli :a CONDUIT DIMENSIONS(IN.) STAINLESS STEEL REGULAR CAT.NO. SIZE(IN.) A B STD.CTN. STD.CTN. TS 101 /2 0.57 1.79 25 100 TS-102 /4 0.62 1.96 25 50 TS-103 1 0.75 2.25 25 50 CONDUIT DIMENSIONS(IN.) ST, LESS STEEL REGULAR TS-104 11/4 0.88 2.85 10 25 CAT.NO. SIZE(IN.) A B STD.CTN. STD.CTN. TS-105 11/2 0.99 3.16 5 20 TS-901 1/2 1 6 2.20 25 250 I TS-106 2 1.10 3.93 5 10 I TS-902 1/4 0..• 2.67 25 200 HS-107 21/2 1.28 5.00 5 25 TS-903 1 0.68 2.97 25 100 HS-108 3 1.28 5.55 5 25 TS-904 11/4 0.75 3.6 10 50 HS-109 31/2 1.28 6.37 5 10 TS-905 I 1'/ 0.88 4 2 5 5 HS-110 4 1.28 6.87 5 10 TS-906 2 1.00 -.91 5 25 'Add SS suffix to part number for Stainless Steel. Add SS suffix to part number for Stainles•Ste.. •ce Caps - Plastic Nail Straps - Ste I • Stamped steel T �� • Zinc plated �A 13 F T t .' 3 B A Spa : .• CONDUIT DIMENSIO 1 IN. STD. RIGID/MC EMT FLEX DIMENSIONS(IN. STD. CAT.NO. SIZE(IN.) A CTN. CAT.NO. SIZE(IN.) SIZE(IN.) SIZE(IN.) A B CTN. BT-501 1/2 215/32 133/34 100 N-101- - 1/2 % 115/16 15%4 1,000 BT-502 3 215/32 14'/64 100 N-10 SC / %4 1/3 23/14 117/32 1,000 BT-503 1 215/x2 131/32 100 N-1 S -SC 3A 1 - 2% 115/x2 000 BT-504 11/4 21%2 23'/64 100 BT- r 11/2 215%2 3%2 11: www.tnb.com R i,, •, „. Steel City® w� 16721 1.6.0.4 Ground Clamps, Pipe Hangers r Ground • : — Die Cast 4146 , Zinc, Brass Colored ora 0 • Two-screw ground connection ��! CONDUIT STD. CA for armored ground wire ;�. _�p—CAT.NO. SIZE(IN.) CTN. GC-203-B200 U U. • 6H Series Conduit and Pipe Hangers —Without Bolt 0 V RIGID CONDUIT OR PIPE EMT DIMENSIONS(IN.) LOAD STD. 0,3_ Mir CAT.NO. SIZE(IN.) SIZE(IN.) A B C D(DIA.) RATING CTN. .., jra eller 6H0 /-12 1/2 3/4 .045 12/2 9/32 500 100 4193 6H0 T 1/4-1/4 /2 1 .045 12/2 %32 500 100 sr c) .045 2% k 6H1 /4 6H2 1 1/4 '/4 .045 13/2 9/32 500 100 �� �� 6H1 T /4 /4 /6 .045 29/32 %32 500 100 '/6 9/a2 500 100 1® Without Bolt 6H21/2 — 11/4 '/6 .045 223/32 9/32 500 100 6H3-SC 114 11/2 1 .045 2% 9/32 500 100 All Steel City 6H Hanger Bolts include 6H4 11/2 — 1 .071 3% 11/32 500 100 a combination Slot-Phillips Head. I 6H5 2 2 11/2 .071 329/32 13/42 500 50 I 6H6 21/4 — 11/4 .071 49/32 11/32 500 50 For hanging conduit(rigid or EMT)and pipe. 6H7 3 — 1/4 .071 53/6 1/32 500 25 The 6H series hangers are fast,easy and economical 6H8 31/2 — 11/4 .071 51/46 1/32 500 25 to use.May be fastened directly to a#500 beam 6H9 4 4 114 .071 5% 11,/ 500 10 clamp through a hole in the base of the hanger by UL File No.E-160899. means of a 1/4-20 stove bolt or suspended on 1/4” Add SS suffix to part number for Stainless Steel. hanger rod. Load rating is 500 lbs.with a safety factor of 3.Available with or without closure bolt. Standard finishes:Electro-Galvanized.(Add SS suffix for Type 302 Stainless Steel) . 6H Series Conduit and Pipe Hangers —With Bolt 0 4 I RIGID CONDUIT OR PIPE EMT DIMENSIONS(IN.) LOAD STD. CAT.NO. SIZE(IN.) SIZE(IN.) A B C D(DIA.) RATING CTN. tx . e • 680 B 3/3-1/2 I 1/2 3/4 .045 12/2 9/32 500 100 6H0 TB 3/6-1/4 /2 3/4 .045 12%2 9/32 500 100 6H Without bolt. 6H-B With bolt 6H1-B /4 3/4 1/4 .045 13/2 /32 500 100 and hex nut. 6H1-TB % 3/4 '/ .045 21/42 9/32 500 100 j ' 6H2-B 1 1 '/e .045 23% 9/32 500 100 (Yl '' ) j ) 6H2-B 6H3 B 1 1'/4 1'/4 /e /8 .045 223/32 9/32045 2% 9/32 500 500 100 ` 1'/2 100 o ® =) UUUU ` 6H4-B 1'/2 — 1 .071 3% 11/32 500 100 � �'"� I 6H5-B 2 2 11/4 .071 329/32 "/32 500 50 6H-T Threaded 6H-TB Threaded 6H6-B 21/2 — 11/4 .071 49/32 1/32 500 50 without bolt with bolt 6H7-B 3 — 1'/4 .071 53/16 1/2 500 25 6H8-B 31/2 — 11/4 .071 51/46 11/32 500 25 ID Dia. E.A 6H9-B 4 _ 4 11/2 .071 51/4 1/32 500 10 �( — UL File No.E-160899. Add SS suffix to part number for Stainless Steel. ) Load rating is 500 lbs.with a safety factor of 3. L i — Available with or without closure bolt. Standard finishes:Electro-Galvanized.(Add SS suffix for Type 302 Stainless Steel) B-II- www.tnb.com R 07 Pg B21 - B50.gxp 6/9/2008 9:56 AM Page B22 -Eki- B22 EMT FITTINGS STEEL - STRAPS Application 16721 1.6.C.4 • For use in mounting EMT conduit - —'L a Product Features CC • All steel construction insures me- a W U)chanical protection 4_. 00 2 F • RACO®steel one-hole straps snap v on to the conduit, allowing the in- 0 a staller to easily position the strap 0 before mounting g • Oversized bolt holes make alignment ONE HOLE PUSH-ON STRAPS of the fastener quick and easy STAMPED STEEL • All straps are zinc electro plated for corrosion protection ORDERING INFORMATION - DIMENSIONS ONE HOLE PUSH-ON STRAPS STAMPED-STEEL CATALOG TRADE SIZE UNIT SHIP UPC NUMBER CTN.QTY. CTN.QTY. BAR CODE 2082 1/2" 100 1000 — 2083 3/4" 50 500 — 2084 1" 50 500 — 2085 1-1/4" — 50 — 2ORa 1-1/9" — tin — MEM Weo1 2088 2" — 25 — —`J +1337 21/2" 25 1339 3" — 25 — 1340 3-1/2" — 10 — 1341 4" — 10 —( 41— B D DIMENSIONS CATALOG A B C D E A NUMBER 2082 1-5/8" 49/64" 1/4" 23/32" 5/8" 2083 2-3/16" 1" 9/32" 59/64" 5/8" A=Overall length 2084 2-9/16" 1-9/32" 9/32" 1-11/64" 3/4" B=Height 2085 3-1/8" 1-41/64" 9/32" 1-17/32" 7/8" C=Hole size 2086 3-5/8" 1-57/64" 11/32" 1-3/4" 1" D=Diameter E—Width of strap 2088 4-7/16" 2-25/64" 11/32" 2-3/16" 1-1/8" 1337 5-5/16" 3-1/16" 21/32" 2-7/8" 1-1/4" 1339 6-1/16" 3-11/16" 21/32" 3-1/2" 1-1/4" 1340 6-7/8" 4-1/4" 21/32" 4" 1-1/4" 1341 7-3/8" 4-3/4" 21/32" 4-1/2" 1-1/4" (14 r ;Si Superstrut illPipe Straps, Conduit Clamps & Hangers 1.6.0.4 Superstrut® Pipe Straps y Pre-Assembled for Easy Handling and Sorting Q Superstrut®Pipe Straps are designed to be twist inserted anywhere 17 Cl) along the slot side of the channel.Pipes can be placed as closely as pipe couplings permit. .....-•...... vli eft •:.•--. C4 Some unique features of the straps include: ✓'. -'�`� Q • Bolt head is combination slot and hex head A for flexibility of attachment .---- CO • Square nut is captivated on the shoulder g for easy one-handed tightening R. eign • Straps are interchangeable with 11/2" strut = for broader application R _ • Straps are shipped assembled so counting and sorting are easier • Pipe or conduit sizes are sown on the strap Oft Design Loads for easy identification 1` • All Superstrut®Straps are preassembled for easy handling and sorting ro RP C▪ a —,AV" s� 701 — Superstrut® Straps for 0.D. Tubing C "" TUBING STEEL STRAP DESIGN LOAD STD. i "'`'11'" CAT.NO. O.D.(IN.) THICKNESS (LBS.) CTN glad _ „CO) = ' 701-V4 1/4 14 ga. 750 100 701-38 % 14 ga. 750 100 Mil plicig 701-1/2-STR 1/2 14 ga. 750 100 701-5/8 /8 14 ga. 750 100 Cl) 7013/4 3/4 14 ga. 750 100 7017/8 /8 14g a. 750 100 700 — Superstrut® Stra s for EMT S�" 701-1-STR 1 14 ga. 750 50 p 701 1 1/8 1Y8 14 ga. 1,000 100 EMT 0.D. STEEL STRAP DESIGN LOAD STD. 701 1 1/4 11/4 14 ga. 1,000 25 CAT.NO. SIZE(IN.) SIZE(IN.) THICKNESS (LBS.) CTN. 701-1-3/8 1% 14 ga. 1,000 100 701-1-1/2 1'/ 14 ga. 1,000 25 Standard Finishes—GoldGah brand.Consult Factory 701-1-5/8 15/8 14g a. 1,000 100 regarding other Finishes and Materials 701-1-3/4 18/4 12 ga. 1,000 25 700 38-STR /8 0.577 14 ga. 750 100 701-1-7/8 1% 12 ga. 1,000 50 700-12-STR /2 0.706 14 ga. 750 100 701-2 2 12 ga. 1,000 50 700-314-STR % 0.922 14 ga. 750 100 701-2-1/8 21/8 12 ga. 1,300 50 700-1-STR 1 1.163 14 ga. 750 100 701-2-1/4 21/4 12 ga. 1,300 25 700-1-V4-STR 1'/4 1.510 14 ga. 750 50 701-2-3/8 2% 12 ga. 1,300 25 700-1-12-STR 1'/z 1.740 12 ga. 800 50 701-2-1/2 2'/z 12 ga. 1,300 25 700-2-STR 2 2.197 12 ga. 800 50 701-2-58 2% 12 ga. 1,300 50 www.tnb.com R f - Superstrut ,_-ft; .-_,- 16721 1.6.C.4 .0 Pipe Straps, Conduit Clamps & Hangers Cobra° One-Piece Cable and Pipe Clamp Takes a bite out of your installation time! .,•,.,'' Co) • One-piece,heavy-duty construction ready to `J r install right out of the box,no need to break .i apart and re-assemble, no screws or bolts to dropriW - • / i i y • Installs quickly and securely using one hand ... Co) • Universal bolt head accepts a range of tools Accepts... Multi-driver combination bolt head accepts • Eliminates the guesswork from clamp a wrench,screwdriver or nut driver. '60 selection-one catalog number attaches = equal trade sizes of EMT and rigid conduit , • Parallel hook design keeps conduits • f , and cable square with strut -- - / • Reconfigure wiring without completeINV' � L disassembly.Remove cables easily ';- QC without disturbing neighboring clamps � 1 CLI Simple Product Selection,Solid Installation Attaches... ■� • Clear markings on each clamp identify the catalog number,13. ��- Attaches a full range of EMT,rigid conduit min./max.outer cable diameters, EMT/Rigid trade sizes, - CSA and UL stamps and cable to strut channels. • Works with all depths of strut-1 3/6" to 3W i • One-size clamp works on equal trade sizes for both EMT and rigid conduit '1,- . 44,X/7" U. • Two hooks on the same side make the clamp easy to install Cti and keep conduits and cable square with strut4, A • Rugged stirrup and wide saddle design holds securely f with no damage to conduit or cable . la'' • Suggested design load is 200 lbs.(W to 2"); 350 lbs.(2%" to 4"). Remove... ,4. Safety factor 4:1 (safety factor= ratio of ultimate load to the design load) Remove cable or pipes easily without disturbing neighboring clamps. i • Heavy-duty%6" hex bolt with multi-driver head (Robertson square,Phillips cross-recess CLI and slot) provides full range of installation options.Virtually any tool will work! • Bright zinc finish-clamps are electrogalvanized after fabrication for additional durability ® sin FOR EMT FOR EMT AND RIGID STATIC LOAD AND RIGID STATIC LOAD CONDUIT CABLE O.D. LIMIT(LB) STD. CONDUIT CABLE O.D. LIMIT(LB) STD. CAT.NO. TRADE SIZE(IN.) RANGE(IN.) SAFETY FACTOR=4 CTN. CAT.NO. TRADE SIZE(IN.) RANGE(IN.) SAFETY FACTOR=4 CTN. Electro-Galvanized Steel 316 Stainless Steel CPC050 1/2 0.650-0.890 200 100 CPC050SS6 'A 0.650-0.890 200 100 CPC075 x 0.860-1.110 200 100 CPC075SS6 4 0.860-1.110 200 100 CPC100 1 1.100-1.400 200 100 CPC100SS6 1 1.100-1.400 200 100 CPC125 1% 1.400-1.725 200 50 CPC125SS6 1% 1.400-1.725 200 50 CPC150 1% 1.690-1.980 200 50 CPC150SS6 14 1.690-1.980 200 50 I CPC200 2 1.980-2.576 200 50 CPC200SS6 2 1.980-2.576 200 50 CPC250 2% 2.576-3.060 350 25 CPC250SS6 2% 2.576-3.060 350 25 CPC300 3 3.060-3.626 350 25 CPC300SS6 3 3.060-3.626 350 25 CPC350 314 3.626-4.126 350 25 CPC350SS6 3% 3.626-4.126 350 25 CPC400 4 4.126-4.626 350 25 CPC400SS6 4 4.126-4.626 350 25 Standard Finish-GoldGalt,unless otherwise stated. Stainless Steel;Add suffix SS or SS316. www.tnb.com R 167211.6.C.4 __ Superstrut Pipe Straps, Conduit Clamps & Hangers IS Angled for Easy Tightening! Angler® Pipe and Conduit Clamp RD Angler PIN y Pipe and Conduit Clamp ^I. 1 ,/14/;//iiiiiii/iiibir 14.1 ivii For EMT, IMC, Rigid and Standard Pipe For Rigid Conduit and Standard Pipe cb Universal Series 0 a Rigid Series C) SH m STRAP DESIGN INSTALL TORQUE STD. STRAP DESIGN INSTALL TORQUE STD. Ca CAT.NO. SIZE(IN.) THICKNESS LOAD(LBS.) (IN.LBS.) CTN. CAT.NO. SIZE(IN.) THICKNESS LOAD(LBS.) (IN.LBS.) CTN. CD Galv-Kron1®Finish GaIv-Krom®Finish y C 1091/2 1/2 14 ga. 400 40 100 C 109R 1/2 / 14 ga. 600 40 100 C 109 3/4 34 14 ga. 500 40 100 C 109R 3/4 / 14 ga. 600 40 100 M. C 1091 1 14 ga. 500 40 100 C 109R 1 1 14 ga. 600 40 100 C 1091 1/4 11/4 14 ga. 500 40 100 C 109R 1 1/4 11/4 14 ga. 600 40 100 CI C 1091 1/2 1'/ 12 ga. 800 60 50 C 109R 1 1/2 11/4 1 12 ga. 800 60 50 CI C 109 2 2 12 ga. 800 60 50 C 109R 2 2 12 ga. 800 60 50 cD C 109 21/2 21/2 12 ga. 800 60 50 C 109 21/2 21/4' 12 ga. 800 60 50 C 109 3 3 12 ga. 800 60 50 C 109 3 3 12 ga. 800 60 50 C 10931/2 31,4 11 ga. 1,200 60 25 C 10931/2 31/2 11 ga. 1,200 60 25 C 109 4 4 11 ga. 1,200 60 25 C 109 4 4 11 ga. 1,200 60 25 1' SilverGaly®Finish SilverGaly"Finish C 1091/2 EG 1/2 14 ga. 400 40 100 C 109R 1/2 EG / 14 ga. 600 40 100 C 109 3/4 EG / 14 ga. 500 40 100 C 109R 3/4 EG / 14 ga. 600 40 100 C 1091 EG 1 14 ga. 500 40 100 C 109R 1 EG 1 14 ga. 600 40 100 C 1091 1/4 EG 1'/4 14 ga. 500 40 100 C 109R 1 1/4 EG 1'/ 14 ga. 600 40 100 C 1091 1/2 EG 11/4 12 ga. 800 60 50 C 109R 1 1/2 EG 1'/ 12 ga. 800 60 50 C 1092 EG 2 12 ga. 800 60 50 C 109R 2 EG 2 12 ga. 800 60 50 C 109 21/2 EG 21/2 12 ga. 800 60 50 C 109 21/2 EG 2% 12 ga. 800 60 50 C 109 3 EG 3 12 ga. 800 60 50 C 1093 EG 3 12 ga. 800 60 50 C 109 31/2 EG 31/2 11 ga. 1,200 60 25 C 109 31/2 EG 31/2 11 ga. 1,200 60 25 C 109 4 EG 4 11 ga. 1,200 60 25 C 109 4 EG 4 11 ga. 1,200 60 25 Hex head size h"for X"to l'A"sizes,X"for 1w"to 4"sizes. Material:Stamped Steel. Pipe sizes 21/4"to 4"utilize the same clamps for the Rigid Series and the Universal Series. • www.tnb.com R iiiiii . . ir. : , Steel,r.:, City® 16721 1.6.C.4 T Thinwall Conduit Fittings (EMT) Set Screw !, Non-Insulated 0 Insulated lug Connectors — , .-. CONDUIT INNER OUTER CONDUIT INNER OUTER Steel 4; el, "A"CAT NO. SIZE(IN.) PACK PACK "A"CAT NO. SIZE(IN.) PACK PACK •' TC121A %z 50 500 TC-721A / 50 500 CA • Concrete ~ TC122A / 50 250 TC722A / 50 250 Qin tight when . • TC123A 1 25 100 TC-723A 1 25 100 1 .•,„.. taped . TC124A 1% • 25 TC724A 1/ 25 • Zinc plated TC125A 1/ — 25 TC725A 11/2 — 25 U▪ . IIC126A 2 — 25 I TC726A 2 — 25 Alk TC127A 21/2 10 TC727A 21/210 , TC128A 3 — 5 TC728A 3 — 5 V TC129A 3% — 5 TC729A 31A — 5 TC1210A 4 — 5 TC7210A 4 — 5 C▪IJ TC121A-FA 1/2 50 500 TC721A-FA / 50 500 oller TC122A-FA % 50 250 TC722A-FA / 50 250 y TC123A-FA • 1 25 100 TC723A-FA `1 25 100 UL File No.E-16592. UL File No.E-16592. FA—Fire Alarm. FA—Fire Alarm. Set Screw Couplings — Steel lug 0 • Concrete tight when taped CONDUIT INNER OUTER CONDUIT INNER OUTER • Zinc plated "A"CAT NO. SIZE(IN.) PACK PACK "A"CAT NO. SIZE(IN.) PACK PACK • Fire Alarm TK121A % 50 500 TK128A 3 — 5 (FA)painted TK122A % 50 250 TK129A 3'/ — 5 red for - , TK123A 1 25 100 TK1210A 4 — 5 fire alarm i •. • TK124A 1'/ — 25 TK121A FA 1/2 50 500 identification •. :: TK125A 1% — 25 TK122A-FA % 50 250 ITK126A 2 — 25 I TK123A-FA 1 25 100 TK127A 21/4 — 10 UL File No.E-16592. UL File No.E-16592. Compression . Non-Insulated 0Insulated 0 Connectors — Iht., CONDUIT INNER OUTER CONDUIT INNER OUTER Steel �, j'!�1 q "A"CAT NO. SIZE(IN.) PACK PACK "A"CAT NO. SIZE(IN.) PACK PACK S,11r 1 : TC111A / 50 500 TC711A / 50 500 • 11/4"—4 . ' TC112A % 50 250 TC712A % 50 250 concrete tight TC113A 1 25 100 TC713A 1 25 100 • Zinc plated TC114A* 114 — 25 TC714A 11/4 — 25 • RT—Raintight TC115A* 1/ — 25 TC715A 11/4 = — 25 TC116A* 2 — 25 TC716A 2 — 25 TC117A 2/ — 10 TC717A 2% mom — 10 Steel City®Raintight EMT Compression Fittings TC118A 3 — 5 TC718A 3 — 5 feature a distinctive design and a vibrant gold TC119A 3/ — 5 TC719A 3/ — 5 gland nut,enabling inspectors to visually inspect TC1110A 4 — 5 TC7110A 4 — 5 conformance from a distance.There's no close- TC111A-RT / 50 500 TC711A-RT / 50 500 up inspection required! TC112A-RT % 50 250 TC712A-RT % 50 250 TC113A-RT 1 25 100 TC713A-RT 1 25 100 TC114A-RT* 11/4 — 25 TC714A-RT* 1' — 25 TC115A-RT* 11 — 25 TC715A-RT* 1/ — 25 TC116A-RT* 2 — 25 TC716A-RT* 2 — 25 TC117ART 2/ — 10 TC717ART 21/4 — 10 TC118ART 3 — 5 TC718ART 3 — 5 TC119ART 3/ — 5 TC719ART 31/4 — 5 TC1110ART 4 — 5 TC7110ART 4 — 5 NOTE A sealing ring is required when fitting is used outside UL File No.E-16592. UL File No.E-16592. on the tops and side of enclosure. *0-rings are supplied. www.tnb.com R ITPuniliP immtpir 1111- .._________ _ . _ .__.7.11 Steel City ,J 16721 1.6.C.4 ,_ Thinwall Conduit Fittings (EMT) - Compression 0 lug Couplings — `i, 44 y CONDUIT INNER OUTER CONDUIT INNER OUTER Steel ..:. "A"CAT Na SIZE(IN.) PACK PACK "A"CAT NO. SIZE(IN.) PACK PACK �� TK111A % 50 250 TK111A-RT / 50 250 • Yz" 4" I TK112A / 50 250 TK112A-RT % 50 250 Cn concrete tight TK113A 1 25 100 TK113A-RT 1 25 100 Cb TK114A 1% — 25 TK114A-RT 1% — 25 CO • Zinc plated TK115A 1% — 25 TK115A-RT 1/ — 25 • RT—Raintight TK116A 2 — 25 TK116A-RT 2 — 25 TK117A 21/2 — 10 TK117A-RT 2/ — 10 TK118A 3 — 5 TK118A-RT 3 — 5 Steel City®Raintight EMT Compression Fittings TK119A 3/ — 5 TK119A-RT _+� — 5 feature a distinctive design and a vibrant gold TK1110A 4 — 5 TK1110A-RT 4 — 5 �■ gland nut,enabling inspectors to visually inspect conformance from a distance.There's no close- UL File No.E-16592. UL File No.E-16592. up inspection required! y Co ,- ation Compression Couplings — Heavywall to Liquidtight Flexible Metal Conduit ' eel • Steel A 1l ,yr 1 CONDUIT I SIONS IN. STD. • Raintight s ac,,1y� CAT.NO. SIZE(IN.) A B C CTN. • Zinc plated corner (1;11 1�V Coner LTH 111 %Rigid to'/Liquidtight 1'/s 1'/4 1'/a 100 • Combination Compression Couplings — nwall to Lir r-r ight Flexible Metal Conduit — Steel • Steel A • Raintight Am emit 4,it CONDUIT DIMENSIONS(IN.) STD. g i y CAT.NO. SIZE(IN.) A B C CTN. • Zinc plated co oer I%���1�� � Comer LTT 111 /EMT to/Liquidtight 13/4 1/ 100 I,>� p ��� LTT-112 %EMT to'A Liquidtight 13A 11'/ 38 50 LTT-113 1 EMT to 1 Liquidtight 1'%s 1'/2 13/4 5 EMT i onduit Connector — Steel v • Simple,one-piece 1 ;- ation with no locknuts ® a • Available in insulated or non-i . .ted throat 4111 CA DESCRIPTION STD.CTN. • Screw designed for exceptional pullout re ' ..nce TC101-SC /"Uninsulated 500 • Captive screw ensures that the screw is intact for in : .tion f TC-102-SC %"Uninsulated 250 and resists backing out after installation I oiAtTC-701-SC h"Insulated 500 • Corrosion-resistant,zinc-chromatic plating .;104j w TC-702-SC %"Insulated 250 • Positive grounding �— UL Listing No.E16592,CSA Listing No.LR-12798. • Vibration-resistant screw design Installation using either slotted or Phillips screwdriver head, 35-in-lb of torque onto the EMT • UL listed and CSA certified NOTE s ive torque could damage EMT or housing. www.tnb.com R FIF • ..=____ _ . __ . .. -limn 16721 1.6.C.4 SteelCity ).1 • Rigid/Intermediate Grade Conduit Fittings _ Locknuts -B L 1 . nuts B Steel/Zinc Plated ` A Die : t Zinc t . A CONDUIT DIMENSIONS(IN.) STD. CONDUI DIMENSIONS IN. STD. CAT.NO. SIZE(IN.) A(MIN.) B(MAX.) CTN. CAT.NO. SIZE(IN.) A(MIN.) B AX.) CTN. Lb LN-100-SC % - - 1,000 LN-201 /, "!V 1.140 2,000 VD LN-101-SC 1/2 0.125 1.140 1,000 LN-202 /4 0.1-! 1.420 1,000 LN-102 3/4 0.140 1.420 1,000 LN-203 1 0.170 1.770 1,000", LN-103 1 0.170 1.770 500 LN-204 1 Y4 0. 70 2.281 500IIIM LN-104 11/4 0.1/1/ 2.251 2uu LN-205 112 0.170 .598 500 LN-105 1'/ 0.170 2.598 100 LN-206 2 0.187 3. 200 imiril LN-106 2 0.187 3.175 50 LN-207 2'/ 0.375 3.562 100 LN-107 21/2 0.375 3.562 30 LN-208 0.375 4.250 100 s. LN-108 3 0.375 4.250 25 LN-209 31/ 0.438 4.803 40 LN-109 3% 0.438 4.803 25 LN-210 4 0.438 5.402 40 Cl) LN 110 4 0.438 5.402 25 = CSA,'•No.LR-12798. LN-111 5 0.500 6.674 10 - LN-112 6 0.561 7.934 10 File No.E-23018. UL File No.E-23018. - • t 1 unding Locknuts Sealing Locknuts B Ma •able - -_� Steel/Zinc Plated ,' A = a Iron/ •c Plated B T (®' (.6 0 0 CONDUIT DIMENSIONS(IN.) STD. CONDUIT DIMENSIO '(IN.) STD. CAT.NO. SIZE(IN.) A(MIN.) B(MAX.) CTN. CAT.NO. SIZE(IN.) A'T® B(MAX.) CTN. LS101 1/2 0.26 1.12 1,000 LG-401 F 0.125 1.140 100 LS-102 14 0.27 1.37 1,000 LG-402 14 0. '1 1.420 100 LS-103 1 0.28 1.75 500 L6-403 1 i.170 1.770 50 LS-104 11/4 0.32 2.06 200 LG-404 11/, 0.170 ' 81 50 LS-105 11A 0.32 2.37 100 LG-405 1/ 0.170 2.5': 50 LS-106 2 0.32 2.87 50 LG-406 2 0.187 3.175 25 LS-107 21A 0.32 3.43 50 LG-407 14 0.375 3.562 10 LS-108 3 0.32 4.12 50 LG-408 3 0.375 4.250 10 LS-109 3% 0.32 4.62 50 16-409 31X 0.438 4.803 ,0 LS-110 4 0.32 5.18 25 = LG 411 4 0.438 5.402 5 UL File No.E-23018. U "de No.E-23018. Loc 1 uts 200"1 I` B Thd. Thi onstruction Non- • .Ilic t .0" Locknu - - - A 1 / `\ Steel/Zinc • led 101-_,405- L `�� moi/ TRADE AD , B THD. STD. CONDUIT .11T STD. CAT.NO. SIZE(IN.) �J (IN.) CTN. CAT.NO. SIZE(IN.) QT'. CTN. LN-501 / 1.3 '2 4 100 SPLN-107 2K 30 30 LN-502 % 1.4 /4-14 100 SPLN-108 25 25 LN-503 1 1.7 1-11/ 50 SPLN-109 3A 25 25 Materia• Ion 6/6. SPLN- , 4 25 s•r:Gray. . : L Listed. www.tnb.com R . 16721 1.6.C.4 Steel City� _..11 ., v, - „, ._ Beam and Purlin Clamps - , ' Beam Clamps (continued) 6H Series Conduit and Pipe Hangers • Accommodates 1/2" through a►y 4" EMT or rigid conduit f • Can be used for either vertical 11111 •• L., r"--' ..,.. 10 •.____ ...,.._ ..._.__. • ci) � or horizontal installation 11:1 WI Fig.2 -g.3 • 6HTB Series have a built-in Fig.1 nut so there are less parts 'm to handle or drop , .....i • Installs easily with �� MC screwdriver ``� IG. O.D.OF CONDUIT NOM.CONDUIT IR STD. Ie Q' CAT.NO. .. OR PIPE(IN.) PIPE SIZE(I'.) CTN. Ca RCS Clamp—St.•I CIS RCS-1/2 1 .840 / 50 RCS-3/4 1 1.050 4 50 _ _ cl RCS-1 1 1.315 1 100 ��► I N u. RCS-1-1/4 1 1.660 1'/4 100 •� ' ...,-„, i)- RCS-1-1/2 1 1.900 2 1004 y RCS-2 1 2.375 2 100 i RC Clamp—Malleable Iratt.411)4 0 it RC-3/8 1 .175 Y. 50 RC 1/2 1 : 0 V2 50 Fig.1 Fig.2 Fig.3 Fig.4 RC-3/4 1 1.0'1 '/, 50 RC-1 1 1.31 1 100 RC-1-1/4 1 1.660 1'/4 100 WITH BOLT WITHOUT BOLT RC-1-1/2 1 1.900 11/2 100 CAT. FIG. CAT. FIG. EMT RIGID CONDUIT STD. RC-2-SC 1 2.37 2 100 NO. NO. NO. NO. (IN.) OR PIPE(IN.) CTN. RC-2-1/2 1 2.8 5 21/4 100 6H0 B 1 6H0 2 / %—%2 100 RC-3 1 3.00 3 100 6H0 TB 3 6H0 4 / %—'/ 100 RC-3-1/2 1 .000 3'/ 100 6H1 B 1 6H1 2 / / 100 RC-4-SC 1 4.500 4 100 6H1-TB 3 6H1 4 / / 100 6H2-B 1 6H2 2 1 1 100 EC Clamp—Malleable!PI? 6H2-TB 4 1 1 100 EC 1/2 2 .840 /2 50 6H2 1/2-B 1 bHz 1/z 2 1/ — 100 EC-3/4 2 1.050 34 50 6H2 1/2-TB 4 1'/ — 100 EC-1 2 1.315 100 6H3-B 1 6H3-SC 2 1'/ 1'/ 100 EC-1-1/4 2 1.660 114 100 6H3-TB 4 1'/ 1'/ 100 EC-1-1/2 2 1.900 1'/2 100 6H4-B 1 6H4 2 — 1'/ 100 EC-2 2 2.375 2 100 6H4-TB 4 — 1'/ 100 EC-2-1/2 2.875 21/4 100 6H5-B 1 6H5 2 2 2 100 EC-3 i 3.500 3 100 6H5-TB 4 2 2 100 PC Clamp— alleable Iron 6H6-B 1 6H6 2 2 2 100 6H7-B 1 6H7 2 3 3 100 PC-3/8 3 .675 /8 50 6H8-B 1 6H8 2 3'/ 3'/ 100 PC 1/2 3 .840 / 50 6H9-B 1 6H9 2 4 4 100 PC-3/4 3 1.050 /4 50 PC-1 3 1.315 100 Add SS suffix to part number for stainless steel. PC-1-1/' 3 1.660 11/4 10 Load rating is 500 lbs.with a safety factor of 3.Available with or without closure bolt. PC-1- /2 3 1.900 11/4 10 Standard finishes:Electro-Galvanized and Type 302 Stainless Steel. PC- 3 2.375 2 100 PC '-1/2 3 2.875 21/4 100 Pt-3 3 3.500 3 100 -3-1/2 3 4.000 31/4 100 'C-4 3 4,500 4 100 www.tnb.com R _. f• . ri• Steel City16721 1.6.C.4 Beam and Purlin Clamps Beam Clamps • Supports threaded rod,threaded bridle rings i %a.- • Brightandelectrical zinc platingboxes _ • Supports 100 lbs.static load limit CIS VS _� �) Malleable Iron, Electro-Plated Finish Fig.1 �L FIG. STATIC LOAD STD. CAT.NO. NO. DESCRIPTION LIMIT(LBS.) CTN. 43 CU BC1-TB 1 Steel beam clamp,4-20 threaded 75 50 y IGO openings,fits flanges up to%"thick BC2-TB 1 Steel beam clamp,46-18 threaded 320 50 MI openings,fits flanges up to%"thick •i JO 510 2 Malleable iron beam clamp,4-20 threaded 400 100 a. openings,fits flanges up to%"thick Cit - 5i i-SC L iviaeeeanle iron nem clamp, IU-24 tnreaaea 4UU IUU VS openings,fits flanges up to%"thick = Fig.2 500-SC 2 Malleable iron beam clamp,4-20 threaded 450 100 CQ openings,fits flanges up to 146"thick y 509 2 Malleable iron beam clamp,10-24 threaded 375 100 openings,fits flanges up tom/6"thick —lb D—k•I 501 2 Malleable iron beam clamp,146 18 threaded 800 100 openings,fits flanges up to X"thick V 502 2 Malleable iron beam clamp,4-16 threaded 1,300 100 ear EN: /s-18 x 1'/"Hex Head, openings,fits flanges up to 1"thick Cup Point,Hardened steel,Cap Screw Note' 503-SC 2 Malleable iron beam clamp,4-13 threaded 1,300 100 CMopenings,fits flanges up to 1"thick _ I•$ 507 2 Malleable iron beam clamp,4-13 threaded 1,700 100 R Il openings,fits flanges up to 1%"thick WC 508 2 Malleable iron beam clamp,4-13 threaded 1,700 100 openings,fits flanges up to 24"thick �= 1 Safely Factor of 3. Load Ratings based on bottom hole of Beam Clamp. V Min. _ C B CSA File No.LR-52208. _ Cup Point 1 i NgDIMENSIONS(IN.) STD. yr CAT.NO. SIZE TAPPED A B C 0 CTN. y A BC1-TB 1 4-20 1'46 1%8 % 146 250 BC2-TB 21%6 4-16 2% 246 b 1146 25 Material:Steel. Finish:Zinc Plated. Malleable Iron, Silver Electro-Plated Finish BASE SIZE JAW TAPPING SET SCREW II T (IN.) OPENING OF BASE AND LOD TORQUE IN STD. .-=.-- 1.16.1111111° � CAT.NO. A B (IN.) BACK HOLES RATING INCH-LBS. CTN. 500-SC 1 1'/4 15/6 /4 20 250 60 50 501 11/2 1% /8 /,6 18 500 60 50 � ,� 502 2 2 I 3/8-16 750 I50 50 `_ 503-SC 278 21/2 1 '/z-13 1,250 250 20 � 507 21/2 2% 1% /z-13 1,250 250 20 500SS316,502SS316 �, 508 2% 2% 2% /3 13 1121,2555A50000 250 10 and 503SS316 in 316 �. 509 1 11/4 15/,6 10-24 60 100 Stainless Steel also available. p-------' B 510 2'/33 11/8 78 /4 20 40 100 511 SC 2732 1 YB 5/8 10-24 40 100 #Safety Factor of 3. Load Ratings based on bottom hole of Beam Clamp. CSA File No.LR-52208. www.tnb.com R A Arlington Conduit Locknuts CATALOG UPC/DCl/NAED TRADE UNIT STD DIM DIM Plated steel. NUMBER MFG#018997 SIZE PKG PKG A B 401 00401 1/2 200 2000 1.125 .130 402 00402 3/4 100 1000 1.383 .140 l(rTh4lii....- , 403 00403 1 100 1000 1.730 .160 404 00404 1-1/4 50 250 2.080 .187 405 00405 1-1/2 50 250 2.376 .187 L 406 00406 2 25 250 2.890 .250 407 00407 2-1/2 30 30 3.470 .250 408 00408 3 25 25 4.165 .250 409 00409 3-1/2 25 25 4.700 .275 410 00410 4 25 25 5.320 .275 16721 1.6.C.4 411 00411 5 10 10 6.487 .450 412 00412 6 10 10 7.830 .450 bh T B to • A / 0 .., W U b -N 1-5 www.aifittings.com Email: sales@aifittings.com Tel: (800)233-4717 Fax: (570) 562-0646 igimirp -� 16721 1 .6.0.4 ,, .. ; Steel City® Rigid/Intermediate Grade Conduit Fittings Con' '' Bushings CONDUIT DIMENSIONS(IN.) STD. CONDUIT DIMENS I (IN.) STD. Die Cast - - ,"!..N• CAT.NO. SIZE(IN.) A B CTN. CAT.NO. SIZE(IN.) B CTN. Insulated Meta -. Alp B BU-801 1/2 1.06 0.43 1,000 BU-806 2 2.68 0.56 250 BU-802 %4 1.31 0.43 1,000 BU-807 /2 3.25 0.90 50 CA • 105°C thermoplastic 111,.jf t BU-803 1 1.59 0.48 500 BU-:: 3 3.87 0.85 25 liners �' BU-804 1Y4 1.96 0.56 250 :U-809 3% 4.37 0.93 25 ,_ U • Heavy reinforced ribs A •--:05 1% 2.18 0.60 I BU-810 4 5.00 0.93 10 UL File No. 018. UL File No.E-23018. Aik Conduit Bushings Die Cast lug lug Zinc - Heavy Reinforced Ribs CONDUIT DIMENSIONS(IN.) D. CONDUIT DIMENSIONS(IN.) STD. _ A CAT.NO. SIZE(IN.) A(MIN.) B(MAX.) CTN. AT.NO. SIZE(IN.) A(MIN.) B(MAX.) CTN. BU201 % 1.05 0.37 1,000 BU-2'. 2 2.69 0.52 250 BU 202 3/6 1.32 0.37 1,000 BU 207 3.23 0.85 50 C•93 10111110 BU-203 1 1.58 0.47 500 BU-208 3 3.84 0.85 25 BU-204 11/4 1.94 0.50 250 BU-209 31/2 4. 0.85 25 0 I B BU-205 1 11 2.20 0.52 250 BU-210 4 5.02 •:5 10 UL File No.E-23018. UL File No.E-23018. Insulated Bushings - 0 lug Thermoplastic CONDUIT DIMENSIONS(IN.) STD. CONDUIT DIMENSIONS(IN.) STD. CAT.NO. SIZE(IN.) A B CTN. CAT.NO. SIZE(IN.) A B CTN. BU-501 / 13/2 13/6 400 BU-507 2'/ 23/2 33/+6 20 . T BU-502 %4 13/2 11%4 400 BU-508 3 9/16 3% 20 � a BU-503 1 BU-504 1% 9/16 19/16 200 BU-509 3% 5/4 42'/64 5 �����/J- BU-505 1% %6 23 6 100 BU-511 5 _ 1 65/16 5 BU-506 2 %6 2"'/,6 60 BU 512 6 1 7'/,6 5 B UL File No.E-23018X"-4"only. UL File No.E-23018 i"-4"only Rated 105°C. Rated 105°C. Bu 'I 's - Iron/Zinc Plated lug co CONDUIT DIMENSIONS(IN.) STD. CONDUIT DIMEN :'S(IN.) STD. ` T CAT.NO. SIZE(IN.) A B CTN. CAT.NO. SIZE(IN.) B CTN. BU-401 / 1142 /,6 1,000 BU 407 2'/ 33/,6 %2 30 BU 402 b 1'b /6 1,000 BU 408 3% 2%2 25 i C) BU 403 1 19/,6 % 500 BU 40' 3% 4'/,6 21/2 25 III`I/- BU-404 1'b 115/,6 1%2 200 : , 0 4 4% 11/46 25 A 05 1% 213/4 9/16 100 BU-411 5 . 42%2 5/,6 10 BU 40 2 245/64 9/6 • UL File No.E-23018 UL File No.E-230 : Grounding Bushings lug lug Die Cast Zinc - Insulated Metallic With Aluminum RADE GROUNDING LUG WIRE SIZ D. TRADE GROUNDING LUG WIRE SIZE STD. CA I. SIZE(IN.) MIN. MAX. CT'. CAT.NO. SIZE(IN.) MIN. MAX. CTN. Lay-in Type Lug BG201 X 14 4 500 BG- 21/2 8 1/0 50 • 105°C thermoplastic liners BG-202 /4 14 4 500 BG-207A /2 6 250 kcmil 50 BG-203 1 14 4 250 B6-208 8 1/0 50 • Heavy reinforced ribs BG-204A 11/4 14 4 200 BG-208A 3 6 250 kcmil 50 BG-204 11/4 8 1/0 200 B6-209 31/2 8 1/0 10 \� BG-205A 1'/2 11 4 100 BG-209A 3'h 6 : .cmil 10 ■ BG-205 11/2 8 1/0 50 BG-210 4 8 1/0 10 li ■' BG-206A 1 14 4 100 BG-210A 4 6 250 kcmil ®/ BG-206 2 8 1/0 50. UL File No.E-3060. UL File No.E-3060. www.tnb.com R A Arlin on 1 Plastic Insulating CATALOG UPC/DCI/NAED TRADE UNIT STD DIM DIM Bushings NUMBER MFG#018997 SIZE PKG PKG A B 105° C rated. 440 00440 1/2 100 1000 1.050 .365 441 4 00441 3/4 100 1000 1.280 .390 442 00442 1 50 500 1.632 .490 443 00443 1-1/4 25 , 250 1.986 .535 1. 444 00444 1-1/2 25 250 2.160 .550 445 00445 2 i 25 I 125 2.680 .600 V 446 00446 2-1/2 10 100 3.150 .635 447 00447 3 rr 10 I 50 3.800 .725 16721 1.6.C.4 448 00448 3-1/2 10 50 4.275 .725 449 00449 4 10 50 ' 4.775 .750 I 4491 04491 5 5 5 6.350 .975 4492 04492 5 5 7.475 .975 II 0 a -R B E105706 LR49636 . Cl, 0 4a 14. I .-,. A 7. W �f 0 X it bfi .- 14 1-5 www.aifittings.com Email: sales@aifittings.com Tel: (800)233-4717 Fax: (570) 562-0646 Pipe Clamps B2000 SERIES 16721 1.6.C.4 PIPE AND CONDUIT CLAMPS • Safety Factor of 5 •Add PA to suffix for pre-assembled pipe clamps • Includes Combination Recess Hex Head Machine Screw and Square Nut Design Load 1 • Material: 16 Ga. (1.5), 14 Ga. (1.9), 12 Ga. (2.6)ASTM A1011 33,000 PSI min. yield and 11 Ga. (3.0)ASTM A1011 HSLA Gr. 50 • Standard finishes: ZN, HDG, SS4, SS6,AL 1, Note: For EMT sizes 21/2" and larger use rigid conduit sizes. .1"" Design Load 2 11111,01011 Design Load 3 THINWALL CONDUIT (EMT) CLAMPS Conduit Material Design Load 1 Design Load 2 Design Load 3 Wt./C Part No. Size Thickness Lbs. kN Lbs. kg Lbs. kg Lbs. kg co L B2000 3/8" (10) 16 Ga. (1.5) 400 (1.78) 50 (.22) 50 (.22) 10 (4.5) +_. co B2001 1/2" (15) 16 Ga. (1.5) 400 (1.78) 50 (.22) 50 (.22) 10 (4.5) R I B2002 3/4" (20) 16 Ga. (1.9) 400 (1.78) 50 (.22) 50 (.22) 11 (5.0) I ° = B2003 1" (25) 14 Ga. (1.9) 600 (2.67) 75 (.33) 75 (.33) 16 (7.2) Q. B2004 11/4" (32) 14 Ga. (1.9) 600 (2.67) 75 (.33) 75 (.33) 19 (8.6) B2005 11/2" (40) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 28 (12.7) B2006 2" (50) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 33 (14.9) RIGID CONDUIT OR PIPE CLAMPS Conduit Material Design Load 1 Design Load 2 Design Load 3 Wt./C Part No. Size Thickness Lbs. kN Lbs. kg Lbs. kg Lbs. kg B2001 3/8" (10) 16 Ga. (1.5) 400 (1.78) 50 (.22) 50 (.22) 10 (4.5) B2008 1/2" (15) 16 Ga. (1.5) 400 (1.78) 50 (.22) 50 (.22) 11 (5.0) B2009 3/4" (20) 14 Ga. (1.9) 600 (2.67) 75 (.33) 75 (.33) 15 (6.8) B2010 1" (25) 14 Ga. (1.9) 600 (2.67) 75 (.33) 75 (.33) 16 (7.2) B2011 11/4" (32) 14 Ga. (1.9) 600 (2.67) 75 (.33) 75 (.33) 20 (9.1) B2012 11/2" (40) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 30 (13.6) B2013 2" (50) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 34 (15.4) B2014 21/2" (65) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 38 (17.2) B2015 3" (80) 12 Ga. (2.6) 800 (3.56) 125 (.56) 125 (.56) 44 (19.9) B2016 31/2" (90) 11 Ga. (3.0) 1000 (4.45) 200 (.89) 150 (.67) 61 (27.6) B2017 4" (100) 11 Ga. (3.0) 1000 (4.45) 200 (.89) 150 (.67) 66 (29.9) B2018 41/2" (115) 11 Ga. (3.0) 1000 (4.45) 200 (.89) 150 (.67) 70 (31.7) B2019 5" (125) 11 Ga. (3.0) 1000 (4.45) 200 (.89) 150 (.67) 77 (34.9) B2020 6" (150) 11 Ga. (3.0) 1000 (4.45) 200 (.89) 150 (.67) 100 (45.3) B2021 7" (175) 11 Ga. (3.0) 1000 (4.45) 250 (1.11) 200 (.89) 115 (52.1) B2022 8" (200) 11 Ga. (3.0) 1000 (4.45) 250 (1.11) 200 (.89) 128 (58.0) B2130 10 (254) 11 Ga. (3.0) 1000 (4.45) 250 (1.11) 200 (.89) 160 (72.6) B2132 12" (305) 11 Ga. (3.0) 1000 (4.45) 250 (1.11) 200 (.89) 185 (83.9) Reference page 126 for general fitting and standard finish specifications. B-Line by ETN 128 Strut Systems • ..-.A- . .-.7. ' ! 1 . ..,•,-.• .., .. . e.. ,,x4-. Steel City — •,,,,. . _...t. 16721 1.6.C.4 �� � �- Conduit and Cable Supports t, - --� Conduit Hangers from Flange, Wire or Rod • CK Series attaches conduit(EMT, Rigid, ENT°and Aluminum)to drop wire, rods or flanges • Application A(vertical flange),supports 25 lbs.static load limit y • Application B(horizontal flange),supports 100 lbs.static load limit ,41 / OLib A VD • Application C(vertical drop wire),supports 50 lbs.static load limit n FIG. STD. ir CAT.NO. NO. DESCRIPTION CTN. IIIIL'''''ll''''ki\4e .skt SSF-CK1/2 1 Conduit hangers for flange,wire or rod 100 SSF-CK3/4 1 Conduit hangers for flange,wire or rod 100 SSF-CK1 2 Conduit hangers for flange,wire or rod 100 ' Iga B Wire/RodCI CB, CONDUIT #10& #8& Y16" Y4"PLAIN& %" PLAIN& weft SIZE #12 WIRE #9 WIRE PLAIN ROD THREADED ROD THREADED ROD 1/2 EMT CK1/2 CK1/2 CK1/2 CK1/2 CK3/4 All- 1/2 Rigid CK1/2 CK1/2 CK1/2 CK3/4 CK3/4 Cn 3/4 EMT CK3/4 CK3/4 CK3/4 CK3/4 CK1 3/4 Rigid CK3/4 CK3/4 CK3/4 CK1 CK1 77 41114, 1 EMT — CK1 CK1 CK1 CK1 1 Rigid — CK1 CK1 CK1 — FlangeKT CONDUIT %s" '/,s"-'/n" 5/,s"-'/a" 7/,s"—'/z" SIZE FLANGE FLANGE FLANGE FLANGE I 1/2 EMT CK1/2 CK1/2 CK3/4 CK3/4 1/2 Rigid CK1/2 CK3/4 CK3/4 CK1 3/4 EMT CK3/4 CK3/4 CK1 CK1 3/4 Rigid CK3/4 CK1 CK1 CK1 Fig. 1 Fig.2 1 EMT CK1 CK1 CK1 CK1 1 Rigid CK1 CK1 Flexible Conduit Hangers from Drop Wire From Drop Wire • One-piece construction • Can be used in vertical or horizontal positions <«<<<<« Mate Fig.1 • Fits 14-2 through 12-3 armored cable (.433"-.535" outer diameter) , • No load rating for positioning only • No installation tools required ata *WO FIG. STD. CAT.NO. NO. DESCRIPTION CTN. ,= SSF-CK535 1 Flexible conduit hanger from drop wire, 100 #8—#12 wire,.433"—.535"0.D.cable www.tnb.com R _. 1.1 re Steel City® p } tf illir .. Conduit and Cable Supports 16721 1.6.C.4 Support Box & Conduits *r from Single-Drop Wires, °� Rods and Flanges qv 01, 0 _ � • Supports conduit on both sides of a junction box 'lir _ • Holes in opposite ends of 18" bar accommodate �L 441 -_-- -- CC and CS Series conduit clips 0 • A center hole accepts BH flange clips and CVC utility 43 43 clip fasteners for attachment to threaded rod air Cr) 4�1 ■i FIG. STD. CAT.NO. NO. DESCRIPTION CTN. lit ' SSF-CX18-C3/8H1/4 1 Support bar for conduit/box,MC/AC cable 25 = Fig 1 '''-'''-‘ to%"flex to A'flange y SSF-CX1 8-C3/8H1/2 1 Support bar for conduit/box,MC/AC cable 25 Ca to%"flex to%s'to A"flange CI) SSF-CX1 8-C1/2 3/4-H1/4 1 Support bar for conduit/box,%"&'X" 1 conduit to A'to A" flange SSF CX18 C1/2 3/4-H1/2 1 Support bar for conduit/box,A'&%" 25 conduit to%s'to A"flange V _ SSF-CX18-C1-H1/4 1 Support bar for conduitbox,1"conduit 25 4w to A"to A"flange SSF-CX18-C1-H1/2 1 Support bar for conduit/box 1"conduit 25 Fig.2 te to tis'to%"flange _ `' SSF-CX18-C3/8S 2 Support bar for conduit/box,MC/AC cable to 25 R / 'A" flex,A"-20 x9/9"stud in center hole W C " SSF-CX1 8-C1/2 3/4S 2 Support bar for conduit/box,A"to%" 25 conduit,A"-20 x9/4"stud in center hole ,� SSF CX18 C1S 2 Support bar for conduit/box,1'conduit to 25 'u 1"flex,A"-20 x tis"stud in center hole lift, SSF-CX18-C3/8 3 Support bar for conduit/box,MC/AC cable 25 Fig.3 to%"flex for screw or threaded rod mount VIIIyI� SSF-CX18-C1/2 3/4 3 Support bar for conduit/box,IA"to%" 25 conduit for screw or threaded rod mount SSF-CX18-C1 3 Support bar for conduit/box,1"conduit for 25 screw or threaded rod mount � SSF-CX18-C3/8UC 4 Support bar for conduit/box,MC/AC 25 I cable to'A"flex from#12 wire through%"rod ° SSF-CX18-C1/2 3/4UC 4 Support bar for conduit/box,A"&%" 25 t,^ conduit from#12 wire through A"rod I Fig.4 SSF-CX18-C1 UC 4 Support bar for conduit/box,1'conduit 25 V, from#12 wire through%"rod iii oil Ili www.tnb.com R Steel City 16721 1.6.C.4 , 44 , .., ," •,c .• _. . . .,„. , 4.t, Stud Wall/Drywall Supports, Clips and Brackets 011 Screw Gun Box Bracket • Self-tapping screws are aligned with i -, the dimples so that the box is straight g r . • Enables mounting of multiple boxes .11 �i gt LL • Preset for metal stud 16" or 24" on center lir • Depth set for 11/2" or 21/8" deep electrical box L L • Installs easily with a screw gun C • SGP and SGA brackets have adjustable tabs , ; _ for 11/2" or 21/" deep boxes Cl) • SGA brackets adjustable for non-standard stud spacing MI .i !_ritFIG. STUD BOX STD. _ii CAT.NO. NO. DESCRIPTION SPACING(IN.) DEPTH(IN.) CTN. mei Fig.1 SSF-SG1-16 1 Preset box bracket 16 11/2 50 SSF-SG1-24 1 Preset box bracket 24 1/ 50 CU CA SSF-SG16A 2 Adjustable box bracket 11-18 1/or 2/ 50 Ci. I IWO diff ® SSF-SG2-16 1 Preset box bracket 16 2/ 50 110 SSF-SG2-24 1 Preset box bracket 24 2/ 50 Fig.2 SSF-SG24A 2 Adjustable box bracket 17-26 1/or 2/ 50 NW RBoxMounting Brackets = for Between Studs g. • Supports electrical boxes,plaster rings or I -voltage V , ' a ° devices from one bracket do Mufti •1 Accommodates 4" or 411,6" bo .., COI • Bendable leg serves a racket stabilizer • SB16F and SB flat versions enable mounting for any st pacing,from 4"to 24" • ackets enable box mounting in all four 90°orientations FIG. STD. CAT.NO. NO. DESC' ' ION CTN. rilWili 7. Ai rill SSF-SB16 1 Box mounting i et for between studs, 25 16"stud spacing Fig.1 Fig.2 SSF-SB24 2 Box mounting bracket for be'it•n studs, 25 24"stud spacing SSF-SB16F 3 Box mounting bracket,flat version, 25 up to 16"stud spacing AI SSF-SB24F 4 Box mounting bracket,flat version, 5 up to 24"stud spacing .3 Fig.4 www.tnb.com[, Wall Studs 16721 1.6.C.4 • Completely adjustable -fits a range of stud spacings and 11/2"or iill •.••• y o 21/8"deep boxes. ,0,0:1,0....... ---- O��G'" "..•;" • Pre-punched screw 0o aG holes provide for easy box installation. • Bar is marked with Telescoping scale for stud spacing. Box Mounting • Finish: Pre-galvanized Bracket pepiaces gg2-16& -_-x. 24 Series e©w BB2-24T UPC/Part Catalog Metal Stud Box Number Number Spacing Qty. 781011 04256 BB2-16T 11"to 18" 50 781011 01664 BB2-24T 15"to 26" 50 Licensed under Patent#5386959 • Patent#5209444 NMI • Designed for pre-fab. I • Box can be attached iIIIAiI1 1111\. to slider bracket ;11 .,i before or after slider is installed on telescoping bra et. • Box location an be field adju -d by Telescoping , lider movin. - ider along Bracket • tele .ping bracket. • S-- Ruff-INT" brochure or pre-fab box assemblies. Finish: Pre-galvanized cglui BB216TS 7B2TS UPC/Part Catalog Stud Spacing Box Number Number Qty. 782051 .8614 BB216TS 11"to 18" 21 7821 41 38628 BB224TS 15"to 26" 20 7: 051 38613 BB2TS Slider Bracket Only 50 Patent#7,472,875 Read safety/installation instruction sheets in packages before use.These products are designed for positioning only.No load rating. 26 16721 1.6.C.4 Wall Studs • Designed for pre-fab.. • Outlet boxes mount to the jil1l° F CROC-LOK with single ° screw. • CROC-LOK box assemblies can be attached before or after the telescoping bar is Ina mounted in the stud wall. • The tool-less design enables CROC-LOKTM CROC-LOK assemblies to be field Box Mounting installed in less than 4 seconds. Bracket Simply squeeze,secure and walk away. • See Ruff-INT" brochure for pre-fab box assemblies. eas UPC/Part Catalog Stud Description Box Number Number Spacing Qty. 782051 51291 BB2CL N/A Croc-Lok only 50 782051 51292 BB216TCL 11"-16" BB216T with 20 Croc-Lok 782051 51293 BB224TCL 15"-24" BB224T with 20 Croc-Lok U.S. Patent#8,403,277 Note: Secures to Cooper B-Line BB2-16T and BB2-24T telescoping brackets only. For a standard 21/8"deep box,the stud depth must be 31/2"or greater. For a shallow 11/2"deep box,the stud depth must be 21/2"or greater. ounting S -ws "N. for BWHS-9 BWHS-9D UPC/Part Catalog Description Box Number Number Qty. 781011 01675 BW #8 x 9/16" 1000 Sheet Metal Screw 781011 04• BWHS-9D : 9/16" 1000 Self-. 'fling Sheet Meta crew Note: BWHS-9&BWHS-9D can be used with all fasteners ..uiring attachment with sheet metal screws,except on BB2-16, BB2- .9, BB2-24&BB2-24D which only BWHS-9 can be used. Read safety/installation instruction sheets in packages before use.These products are designed for positioning only.No load rating. COOPER B-Line f• - • ei Steel City® 16721 1.6.C.4 wj.. R } • Acoustical Tee Supports, Clips and Brackets Snap-On Box Hanger 1 • Enables positioning of fixture • Part includes dual-height feature V00 D,C O ,__> or box anywhere across which enables 1 W"deep electrical a 24"span box to be mounted flush with tile L • Hanger comes complete with or offset%"for plaster ring qi `; THC box mounting clip and • The series includes bar hanger 1/4-20 screw THC clip and%-20 x 38"screw CD y • Drop wire holes in tee clips • The clip is furnished and the clip enable support with 1A-30 x'A"screw n ta IAN 9 if from main structure Cb 04 par FIG. STD. Cr) Fig'1 Fig.2 CAT.NO. NO. DESCRIPTION CTN. MI V SSF-TH12 1 T-grid box hanger,12"span 25 ■i SSF-TH2O 1 T-grid box hanger,20"span 25 a. SSF-TH24 1 T-grid box hanger,24"span 25 Ci) SSF-TH30 1 T-grid box hanger,30"span 25 ✓S SSF-TH24A 2 8"height adjustable,24"span ` 25 SSF-THC 3 Snap-on fixture/box hanger mounting clip 100 CU Fig.3 Fig.4 SSF-MH1/4-3/8 4 1A-20 x3/4"bolt combo head 100 COI M. Suspension Bars for Lightolier° Calcu ' ii Series Fixtures* � .... ' &.--at. 1 • Reduces installation time _ • Hanger comes complete with bar rivet.: o acoustical tee clip, 4"44 ▪R11 additional acoustical tee clip and 1/, 0 screw \`/ • Position of fixture adjustable ,' span •i� • Solid bar for sturdier in a lation V • Installs easily wit, . screwdriver Mufti Fig.1 yq FIG. STD. CAT.N p NO. DESCRIPTION CTN. -TL24 1 Suspension bars for Lightolier Calculite 10 NOTE:Lightolier and Calculite are registered trademarks of Lightolier and GENLYTE Company Light Fixtu - upport Clips • Enlarged tab enables e. positioning of the clip over the tee bar ® • Fits round-or rectangular-heat •e bar l�� • Gives a positive method of supporting offers and lay ins /, • No installation tools required Fig.1 FIG. STD. CAT.NO. NO. DESCRIPTION CTN. SSF-TFC 1 Light fixture support clip 40 www.tnb.com R Series 5 16721 1.6.C.4 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets Eaton's Crouse-Hinds Series 5 die cast copper-free aluminum Series 5 Features: conduit bodies,covers and gaskets are available for use with rigid or EMT conduit(with set screw).Conduit bodies are available in trade • Integral gasket covers.The new sizes'/2"-4";in the most popular conduit body shapes(C,LB,LL, sheet aluminum covers feature a LR,T)and'/z"-2"in TB and X shapes.The Series 5 family is available raised dome with stainless steel as components or pre-packaged in various configurations as a screws supplied with nylon SnapPackTM assembly.In addition,Series 5 is completely washers and a gasket for interchangeable with other manufacturers. simplifying installation— reducing inventory and labor (1=0n costs.These innovative covers are UL and cUL Listed and are NEMA 4 Rated. j I • SnapPackT"'.Designed for ordering and receiving convenience, the SnapPack combines a body,gasket,and sheet aluminum cover in a single assembly. — Rigid body with traditional cover and gasket(e.g.LB15 Applications: cGN) • Act as pull outlets for conductors being installed • Provide openings for making splices and taps in conductors • Act as outlets for lighting fixtures and wiring devices — Combination body with traditional cover and gasket • Connect conduit sections (e.g.LB15 MTC) • Provide taps for branch conduit runs • Make 90°bends in conduit runs • Provide for access to conductors for maintenance and future — NEMA 4 rigid body with new system changes integral gasketed cover(e.g. X15 ICG) Features/Benefits: • Die cast copper-free aluminum construction is lightweight and corrosion resistant for long reliable service • Epoxy powder coat finish provides additional corrosion resistance in an aesthetically pleasing appearance • Conduit bodies are supplied with threaded hubs for use with Rigid/IMC conduit or as a combination body(threaded and with set screws for use with EMT or Rigid/IMC conduit on trade sizes) • Domed aluminum cover provides additional cubic capacity • SnapPackTM available in choice of 3 configurations to match customer preferences. Certifications & Compliances: • UL Listed • cUL Listed • UL File No.E-15022 Standard Materials: • Bodies—Copper-Free Aluminum with epoxy powder paint • Covers—Aluminum with stainless steel screws,natural finish • Gaskets—Neoprene Crouse-Hinds by E:T•N www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright°2013 Eaton's Crouse-Hinds Business i99 Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets 16721 1.6.C.4 IMF a a MI U UM" TYPE LB Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover,and Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# Gasket Cat# Cover&Gasket Cat#Cu.In. Qty 100* Conductors '/," LB15 LB15 MT LB15 CGN LB15 MTC LB15 ICG 4 35 10 26 - '/4" LB25 LB25 MT LB25 CGN LB25 MTC LB25 ICG 7.3 10 48 3#6 AWG 1" LB35 LB35 MT LB35 CGN LB35 MTC LB35 ICG 12.2 5 64 3#4 AWG 174" LB45 LB45 MT LB45 CGN LB45 MTC - 32.3 2 140 3#2 AWG 1'/z" LB55 LB55 MT LB55 CGN LB55 MTC - 33.8 2 160 3#'/o AWG 2" LB65 LB65 MT LB65 CGN LB65 MTC - 71.2 1 260 3#4/.AWG 2'/o" LB75 LB75 MT*t LB75 CGN LB75 MTC - 71.2 1 500 3#300 MCM 3" LB85 LB85 MT*t LB85 CGN LB85 MTC - 183.5 1 600 3#350 MCM 372" LB95 LB95 MT*t LB95 CGN LB95 MTC - 304.9 1 900 3#350 MCM 4" LB105 LB105 MT*t LB105 CGN LB105 MTC - 308 1 1000 3#350 MCM tCombo EMT,Rigid/IMC Fittings greater than 2'trade size are SET-SCREW ONLY(not combination threaded and set-screw) *Weight Lbs Per 100 is listed for outlet body only MU IMP &Eh TYPE LR Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover,and Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# Gasket Cat# Cover&Gasket Cat#Cu.In. Qty 100* Conductors '/2" LR15 LR15 MT LR15 CGN LR15 MTC LR15 ICG 4.35 10 26 - '/4" LR25 ' LR25 MT LR25 CGN LR25 MTC LR25 ICG '7.3 '10 '48 3#6 AWG 1" LB35 LR35 MT LB35 CGN LR35 MTC LR35 ICG 12.2 5 64 3#4 AWG 114" LR45 LR45 MT LR45 CGN LR45 MTC - 35.8 2 140 3#2 AWG 1'/z" LR55 LR55 MT LR55 CGN LR55 MTC - 35.8 2 160 3#'/o AWG 2" LR65 LR65 MT LR65 CGN LR65 MTC - 69.7 1 260 3#4/o AWG 2'/z" LR75 - - - - 69.7 1 500 3#300 MCM 3" LR85 - - - - 186 1 600 3#350 MCM 3'/2" LR95 - - - - 306 1 900 3#350 MCM 4" LR105 - - - - 308 1 1000 3#350 MCM 'Weight Lbs Per 100 is listed for outlet body only Crouse-Hinds 200 www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright" 2013 Eaton's Crouse-Hinds Business by E:T•N 16721 1.6.C.4 Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets dna illni 0 TYPE LL Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover,and Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# Gasket Cat# Cover&Gasket Cat# Cu.In. Qty 100* Conductors 11," 1 115 LI 15 MT 1115 CGN 1115 MTC 1115 ICG 4 35 10 3n - 3/4" LL25 LL25 MT LL25 CGN LL25 MTC LL25 ICG 7.3 10 48 3#6 AWG 1" LL35 LL35 MT LL35 CGN LL35 MTC LL35 ICG 12.2 5 64 3#4 AWG 114" LL45 LL45 MT LL45 CGN LL45 MTC - 35.8 2 140 3#2 AWG 11/2" LL55 LL55 MT LL55 CGN LL55 MTC - 35.8 2 160 3#To AWG 2" LL65 LL65 MT LL65 CGN LL65 MTC - 69.7 1 270 3#4/o AWG 2'h" LL75 - LL75 CGN - - 69.7 1 500 3#300 MCM 3" LL85 - LL85 CGN - - 186 1 600 3#350 MCM 3'/2" LL95 - LL95 CGN - - 306 1 900 3#350 MCM 4" LL105 - LL105 CGN - - 308 1 1000 3#350 MCM `Weight Lbs Per 100 is listed for outlet body only 111.11 III TYPE C Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover,and Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# Gasket Cat# Cover&Gasket Cat# Cu.In. Qty 100* Conductors 'G" I.U. G.Si Clc WiiG7RrMM - 3/4" C25 C25 MT C25 CGN C25 MTC C25 ICG 7.3 10 40 3#6 AWG 1" C35 C35 MT C35 CGN C35 MTC C35 ICG 12.2 5 64 3#4 AWG I 1/4 C4b -1:4b M I C4b CGN U4b M I C. - 6Z.6 L I bb 6 8 L AVVG 1'/2" C55 C55 MT C55 CGN C55 MTC - 33.8 2 150 3#'/o AWG 2" C65 C65 MT C65 CGN C65 MTC - 69.5 1 270 3#To AWG 2'/2" C75 - - - - 69.5 1 500 3#300 MCM 3" C85 - - - - 188 1 600 3#350 MCM 3'/2" C95* - - - - 307 1 900 3#350 MCM 4" C105* - - - - 309 1 1000 3#350 MCM Crouse-Hinds by E:T•N www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright°2013 Eaton's Crouse-Hinds Business 201 Series 5 16721 1.6.C.4 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets MIMI im 0 TYPE T Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover,and Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# Gasket Cat# Cover&Gasket Cat# Cu.In. Qty 100* Conductors 'G" T15 T15 MT T15 CGN T15 MTC T15 ICG 4.35 10 27 - 'A" T25 T25 MT T25 CGN T25 MTC T25 ICG 7.3 10 40 3#6 AWG 1" T35 T35 MT T35 CGN T35 MTC T35 ICG 12.2 5 64 3#4 AWG 1'/4" T45 T45 MT T45 CGN T45 MTC - 33.1 2 165 3#2 AWG 1'/z" T55 T55 MT T55 CGN T55 MTC - 33.1 2 150 3#'/o AWG 2" T65 T65 MT T65 CGN T65 MTC - 67 1 270 3#V.AWG 272" T75 - T75 CGN - - 67 1 500 3#300 MCM 3" T85 - T85 CGN - - 175 1 600 3#350 MCM 372" T95* - T95 CGN - - 298 1 900 3#350 MOM 4" T105* - T105 CGN - - 300 1 1000 3#350 MCM 1 TYPE TB Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover, Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# and Gasket Cat# Cover&Gasket Cat# Cu.In. Qty 100* Conductors '/2" TB15 - - - TB15 ICG 4.5 10 29 - S/" TB25 - - - TB25 ICG 7.5 10 42 3#6 AWG 1" TB35 - - - TB35 ICG 10.8 5 58 3#4 AWG 1'A" TB45 - - - - '32.3 2 110 -3#2 AWG 1'A" TB55 - - - - 34.2 2 109 3#2 AWG 2" TB65 - - - - 71.4 1 192 3#°/o AWG ■It . ' ,111 11111 TYPE X Outlet Body SnapPack Combo EMT, Rigid/IMC Body, Combo EMT,Body, NEMA 4 Rigid/IMC Internal Weight Trade Rigid/IMC Rigid/IMC Traditional Cover, Traditional Cover, Body and Integral Col.ln Unit Lbs Per Max#of Size Cat# Cat# and Gasket Cat# and Gasket Cat# Cover&Gasket Cat# Cu.In. Qty 100* Conductors '/" X15 - - X15 ICY a F 111 '11 - '/4" X25 - - - X25 ICG 7.5 10 47 3#6 AWG 1" X35 - - - X35 ICG 10.8 5 62 3#4 AWG 1'A" X45 - - - - 32.3 2 118 3#2 AWG 1'/2" X55 - - - - 34.2 2 118 3#2 AWG 2" X65 - - - - 71.4 1 213 3#°/0AWG *Weight Lbs Per 100 is listed for outlet body only Crouse-Hinds 202 www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright. 2013 Eaton's Crouse-Hinds Business by E:T•N 16721 1.6.C.4 Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets INTEGRAL GASKET COVERS ALUMINUM COVERS Aluminum Cover Aluminum with Neoprene Integral Gasket ft ' '"`j -- "+`� Trade Size Cat.# Unit Qty. Weight Lbs.Per 100 Trade Size Cat.# Unit Qty. Weight Lbs.Per 100 73" 150 50 5 1/2. 3/4" 250 50 6 3/4" 250G 50 6 1" 350 50 7 1" 350G 50 8 11/4"-11/2" 450 50 15 11/4"-11/2" 450G 50 17 2" 650 25 24 2" 650G 25 26 21/2"-3" 850D 10 78 21/2"-3" 850G 10 80 31/2" -4" 950D 10 140 31/2"-4" 950G 10 145 '/"-3"are NEMA 4 Rated GASKETS Neoprene SIM Trade Size Cat.# Unit Qty. Weight Lbs.Per 100 1/2" GASK015N 50 2 3/4" GASK025N 50 2 1" GASK035N 50 3 11/4"-11/2" GASK045N 50 6 2" GASK065N 25 10 21/2"-3" GASK085N 10 20 31/2"-4" GASK095N 10 30 TYPE LB DIMENSIONS-THREADED & SET SCREW AIM. _ Trade Size A B C D E F "C"Thread Size - 14" 1.31 3.87 0.50 2.11 x.24 1.07 E 3/4" 1.53 4.67 0.75 2.38 4.97 1.28 1" 1.74 5.37 1.00 2.74 5.79 1.56 B 1'/4" 2.49 7.23 1.25 3.50 7.79 1.99 11/2" 2.49 7.23 1.50 3.65 7.81 2.27 T D it 2" 3.10 9.46 2.00 4.24 10.20 2.91 21/2" 4.44 12.22 2.50 5.75 13.14 3.43 I 3" 4.44 12.22 3.00 6.41 13.14 4.13 31/3" 5.42 14.83 3.50 7.11 15.46 4.65 h-F- 4" 5.42 14.83 4.00 7.20 15.46 5.16 TYPE LR DIMENSIONS-THREADED & SET SCREW (-7111 " Trade Size A B C D E F L 1. Thread Size 1/2" 1.31 3.87 0.50 2.06 4.40 1.40 E 3/4" 1.53 4.67 0.75 2.28 5.07 1.64 1" 1.74 5.37 1.00 2.51 5.94 1.90 B 11/4" 2.49 7.23 1.25 3.50 7.87 2.85 T ^ r 11/2" 2.49 7.23 1.50 3.50 7.87 2.85 F I\ 2" 3.10 9.46 2.00 3.83 9.88 3.41 `'�Q 21/2" 4.50 12.22 2.50 6.00 13.14 4.00 3" 4.65 12.22 3.00 6.10 13.00 4.70 31/2" 5.42 14.83 3.50 6.40 15.45 5.43 4" 5.42 14.83 4.00 6.40 15.45 5.43 Crouse-Hinds by E:T•N www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright°2013 Eaton's Crouse-Hinds Business 203 16721 1.6.C.4 Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets -� TYPE LL DIMENSIONS-THREADED & SET SCREW D � " Trade Size A B C D E F 1 "C"Thread Size II=1 '/2" 1.31 3.87 0.50 2.06 4.40 1.40 E 3/4" 1.53 4.67 0.75 2.28 5.07 1.64 1" 1.74 5.37 1.00 2.68 5.94 1.90 11/4" 2.49 7.23 1.25 3.50 7.87 2.85 B 1 1'/2" 2.49 7.23 1.50 3.50 7.87 2.85 d -N T 2" 3.10 9.46 2.00 3.83 10.20 3.41 U O., 2'/2" 4.50 12.22 2.50 6.00 13.14 4.00 3" 4.65 12.22 3.00 6.10 13.00 4.70 31/2" 5.42 14.83 3.50 6.05 15.35 5.43 4" 5.42 14.83 4.00 6.05 15.35 5.43 "C"Thread Size TYPE C DIMENSIONS-THREADED & SET SCREW Trade Size A B C D E F 1 1 A 1/2" 1.31 3.87 0.50 1.40 4.82 1.07 E H 3/" 1.53 4.67 0.75 1.64 5.50 1.35 1" 1.74 5.37 1.00 1.90 6.44 1.67 11/4" 2.49 7.23 1.25 2.73 8.45 2.27 -B 11/2" 2.49 7.23 1.50 2.73 8.45 2.27 FT'i 2- 2 3.10 9.46 2.00 3.41 10.71 2.91 1 21/2" 4.50 12.22 2.50 4.30 14.00 3.50 3" 4.65 12.22 3.00 4.66 13.80 4.13 31/2" 5.42 14.83 3.50 5.36 16.10 5.30 4" 5.42 14.83 4.00 5.36 16.10 5.30 "C"Threetl 6lze TYPE T DIMENSIONS-THREADED & SET SCREW Ilif Tp Trade Size A B C D E F 1.1 1/2" 1.31 3.87 0.50 1.40 4.82 1.07 E 3/4" 1.53 4.67 0.75 1.64 5.40 1.35 1" 1.74 5.37 1.00 1.90 6.33 1.15 B - 11/4" 2.49 1.23 1.25 2./3 8.45 2.2/ c O r p 11/2" 2.49 7.23 1.50 2.73 8.45 2.27 L 2" 3.10 9.46 2.00 3.41 10.71 2.91 21/2" 4.50 12.22 2.50 4.00 14.00 3.50 3" 4.65 12.22 3.00 4.66 13.80 4.13 31/2" 5.42 14.83 3.50 5.40 16.00 5.30 4" 5.42 14.83 4.00 5.40 16.00 5.30 -"C"THREADSIZE TYPE TB DIMENSIONS-THREADED & SET SCREW i , E O ,-� '/2Trade Size A B C D E F A " 1.31 3.92 0.50 2.10 4.72 1.07 I 3/4" 1.53 4.64 0.75 2.40 5.51 1.28 1" 1.74 5.38 1.00 2.77 6.47 1.56 E 1'/4" 2.49 1.24 1.44.5 3.53 8.2b 1.99 11/2" 2.49 7.24 1.50 3.53 8.25 2.27 B 2" 3.10 9.50 2.00 4.50 10.50 2.91 J L F l D "C"THREAD SIZE TYPE X DIMENSIONS-THREADED &SET SCREW IMI Trade Size A B C D E F II Fj A 1/2" 1 31 3.92 0 50 1 37 4 72 1 07 3/4" 1.53 4.64 0.75 1.63 5.51 1.28 IMI 1" 1.74 5.38 1.00 1.88 6.47 1.56 11/4" 2.49 7.24 1.25 2.51 8.25 1.99 E 11/2" 2.49 7.24 1.50 2.50 8.25 2.27 B 2" 3.10 9.50 2.00 3.40 10.50 2.91 F _ ---1 L J Crouse-Hinds 204 www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright® 2013 Eaton's Crouse-Hinds Business by E:T•N 16721 1.6.C.4 COO , . _ y- _ FIRE ALARM - '. _ BOXES . , , _ _ _ _ _. __ _ - ., . __. _ _ . _ . �it.J The National Electrical Code® defines —�- 1 a fire alarm circuit as "the portion of the wiring system between the `- load side of the overcurrent device t . or the power-limited supply and the 4 . • • • , + I connected equipment of all circuits • ~ ' _ • powered and controlled by the fire 4, I it alarm system." Additionally, the • I *' • NEC requires that all fire alarm circuits be identified at terminal and �t .-dip junction locations in a manner that r will prevent unintentional interference with the signaling circuit during testing and servicing. Cooper Crouse-Hinds®steel Fire Alarm Boxes help meet those installation requirements and are FEATURES AND BENEFITS available in the most popular 4" and 4 11/16" square boxes along • Red epoxy paint allows for quick identification of with covers and box extensions. fire alarm systems meeting NEC® requirements A 4" octagon box is also available. • Eliminates the need to paint boxes on the job site, The red paint allows inspectors to saving time and expense quickly identify fire alarm circuit outlet • UL Listed for use in two-hour, fire-rated walls boxes. The boxes are UL Listed • Available in 4" and 4 11/16" square and 4" octagon, with a two-hour fire rating and are 1 1/2" and 2 1/8" deep welded or drawn construction available in a variety of configurations to meet various applications and/or preferences to meet varied applications. MATERIALS FINISH • Outlet Boxes: Pre-Galvanized Steel • Red epoxy paint CERTIFICATIONS AND COMPLIANCES • UL Listed CROUSE - HINDS 0 COMMERCIAL COOPER Crouse-Hinds PRODUCTS National Electric Code®and NEC®are registered trademarks of the National Fire Protection Assoc. Inc. FIRE ALARM BOXES 16721 1.6.X.4 L .. •• .... .. .._ •• • •, :I • .� . . I i : i ..• • A -'• ', • , TP404RED TP423RED TP414RED TP434RED TP403RED TP451RED x , 1 ..,_.„,... -. l ',. 11111 ma.• f 1 , . .. il • ..... . • TP428RED TP472RED TP556RED TP564RED TP568RED TP292RED ORDERING INFORMATION Catalog Depth Cubic In. Knockouts Std.Unit Wt.Lbs. Number Description Size Capacity Bracket Pkg. Per 100 Sides Bottom TP404RED 4"SQ BOX SHALLOW WELDED 1 1/2" 22 - 8 1/2",4 1/2"&3/4"E 2 1/2",2 1/2"&3/4" E 50 72 TP423RED 4"SQ BOX SHALLOW WELDED 1 1/2" 22 VMS 6 1/2",3 1/2"&3/4"E 2 1/2",2 1/2"&3/4"E 25 81 TP414RED 4"SQ BOX SHALLOW DRAWN 1 1/2" 21 - 8 1/2",4 3/4" 3 1/2",2 3/4" 50 67 TP434RED 4"SQ DEEP DRAWN 1 1/2" 30.3 - 8 1/2",4 3/4" 3 1/2",2 3/4" 25 84 TP403RED 4"SQ BOX DEEP WELDED 2 1/8" 30.3 - 8 1/2",4 1/2"&3/4"E 2 1/2",2 1/2"&3/4"E 25 84 TP451 RED 4"SQ BOX DEEP WELDED 2 1/8" 30.3 VMS 6 1/2",3 1/2"&3/4"E 2 1/2",2 1/2"&3/4"E 25 96 TP428RED 4"SQ EXTENSION RING 1 1/2" 21 - 8 1/2",4 3/4" - 50 46 TP472RED 4"SQ FLAT BLANK COVER - - - - - 50 31 TP556RED 4 11/16"SQ BOX DEEP 2 1/8" 42 - 8 1/2",4 3/4" 3 1/2",2 3/4" 25 104 TP564RED 4 11/16"SQ EXTENSION RING 2 1/8" 42 - 8 1/2",4 3/4" - 25 84 TP568RED 4 11/16"SO FLAT BLANK COVER - - - - - 25 40 TP292RED 4"OCTAGON DEEP OUTLET BOX 2 1/8" 21.5 - 2 1/2",2 3/4" 3 1/2",2 3/4" 25 64 For more information: Contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Canada: Cooper Crouse-Hinds Cooper Crouse-Hinds Canada Distributed by: P.O.Box 4999 Toll Free:800-265-0502 Syracuse,NY 13221 Toll Free:866-764-5454 (315) 471 (315) FAX:(315)477-5179 For office locations outside of North America or for additional product information, visit our crouse.customerctr@crouse-hinds.com crouse-hinds.com Website at:www.crouse-hinds.com Mexico • Latin America/Caribbean • Germany • Australia • Asia • Dubai • India COOPER Crouse-Hinds nsxix , = ISO 0001Solutions.Worldwide:M COOPER cxousx.xixxx Crouse-Hinds is a registered trademark of Cooper Industries,Inc. 4889-0107 ©2007 Cooper Industries,Inc. Printed in U.S.A A20 4" SQUARE BOXES 1-1/4" AND 1-1/2" DEEP/CONDUIT 16721 1.6.C.4 Applications • Boxes are installed in walls or cell- k`;; • CO Ings for lighting fixtures,switches Xor receptacles o m • Square boxes are used where multi 189SM 189F 189,8189 911-9 190,8190 191,8191 W> ple conductor runs are split into two W 0 or more directions to bring power to oas a number of electrical devices r v • Drawn boxes are ideal for exposed 04 work applications cc Product Features • Combination screw heads provide 192,8192 192SM 181 185 204 for faster installation • Thru-the-wall box is designed for ORDERING INFORMATION - DIMENSIONS shallow wall applications and allows for attachment of wall plate to both 4"SQUARE-1-1/4"DEEP(INSIDE)-DRAWN WITH CONDUIT KO'S-18.0 CUBIC INCHES faces of box CATALOG UBS KNOCKOUTS STD. RAISED PIG- UPC • TKO®knockouts offer greater flexibili- NUMBER FARSIDE SIDES COND. BOTTOM COND. PKG. GROUND TAIL BAR ty with RACO®patented combination SUPPORT PROVISION CODE 1/2"and 3/4"knockout 185 — 10-1/2" 5-1/2" 50 No No 111111 • TKO®knockouts allow for design and installation flexibility 4"SQUARE-1-1/2"DEEP(INSIDE)-DRAWN WITH CONDUIT KO'S-21.0 CUBIC INCHES • UBS Support-Welded to box,preset CATALOG UBS KNOCKOUTS STD. RAISED PIG- UPC bend points to work with wall thick- NUMBER FARSIDE PKG. GROUND TAIL BAR ness 2-1/2"to 6" SUPPORT SIDES BOTTOM COND. COND. PROVISION CODE • Red boxes,covers and extensions for 190 — 12-1/2" 4-1/2" 50 Yes No 11111111 dedicated life safety alarm circuits 8190 — 12-1/2" 4-1/2" 50 Yes No 11111111 Compliances 191 — 8-3/4" 1-1/2",3-3/4" 50 Yes No 11111111 • 0 -File E195978 8191 — 8-3/4" 1-1/2",3-3/4" 25 Yes No 11111111 192 — 8-1/2",4-3/4" 2-1/2",2-3/4" 50 Yes No 11111111 All RACO®single gang,two gang,4" 8192 — 8-1/2",4-3/4" 2-1/2",2-3/4" 50 Yes No 11111111 square,and single gang gangable U.L. 192SM — 8-1/2",4-3/4" 2-1/2",2-3/4" 50 Yes Yes 11111111 listed steel boxes are acceptable for use in 2-hour fire rated walls.For additional information,consult U.L."Fire 4"SQUARE-1-1/2"DEEP(INSIDE)-WELDED WITH CONDUIT KO'S-21.0 CUBIC INCHES Resistance Directory"or the U.L.web- CATALOG UBS KNOCKOUTS STD. RAISED PIG- UPC site at www.ul.com NUMBER FARSIDE SIDES COND. BOTTOM COND. PKG. GROUND TAIL BAR SUPPORT PROVISION CODE soov Per U.L.514-A,suitable for use — without a bonding jumper in circuits up 181 — 83/4" 1 1/2",4-3/4" 50 No No — to 600 volts 600V 189 — 8-1/2",4-TKO® 2-1/2",2-TKO® 50 Yes No — soov 8189 — 8-1/2",4-TKO® 3-1/2",2-TKO® 50 No No 11111111 600V 189SM — 8-1/2",4-TKO® 2-1/2",2-TKO® 50 Yes Yes — soov 189F Yes 8-1/2",4-TKO® 2-1/2",2-TKO® 50 Yes Yes — soov 911-9 — 8-1/2",4-TKO' 3-1/2",2-11(0" 50 No No — 4"SQ.-THRU-THE-WALL BOX-1-1/2"DEEP(INSIDE)-DRAWN WITH CONDUIT KO'S-22.5 CU.IN. CATALOG UBS KNOCKOUTS CU. STD. PIG- UPC NUMBER FARSIDE SIDES COND. BOTTOM COND. IN. PKG. TAIL BAR SUPPORT _ CODE 204 — 8-1/2",4-3/4" — 22.5 50 No - 4714,THE INSIDER®will secure nonmetallic sheathed cable in 1/2"KO(See pg.B87) RACO" 11101% 4" SQUARE BOXES 25 16721 1.6.C.4 2-1/8" DEEP/CONDUIT Applications _ - • Boxes are installed in walls or cell- +� ; ..• ings for lighting fixtures,switches :'. > or receptacles _ o • Square boxes are used where multi- o'°N ple conductor runs are split into two 231,8231 232,8232 232F 232SM 233,8233 911-3 O m or more directions to bring power to m a number of electrical devices y W Product Features O ORDERING INFORMATION - DIMENSION k • Combination screw heads provide for - m faster installation • TKO®knockouts offer greater flexibili 4"SQUARE–2-1/8" DEEP(INSIDE)–WELDED WITH CONDUIT KO'S–30.3 CUBIC INCHES ty with RACO®patented combination CATALOG UBS _ KNOCKOUTS STD. RAISED PIGTAIL UPC 1/2"and 3/4"knockout NUMBER FARSIDE SIDES BOTTOM PKG. GROUND BAR SUPPORT - PROVISION CODE • Red boxes,covers and extensions for COND. COND. dedicated life safety alarm circuits 231 — 8-3/4" 1-1/2",4-3/4" 25 No No — Compliances 8231 — 8-3/4" 1-1/2",4-3/4" 25 No No 11111111 • 0 – File E195978 soov 232 — 8-1/2",4-TKO® 2-1/2",2-TKO® 25 Yes No — 1soov 8232 — 8-1/2",4 TKO® 3-1/2",2-TKO® 25 No No 11111111 ,40 All RACO®single gang,two gang,4" square,and single gang gangable soov 232F Yes 8-1/2",4-TKO® 2-1/2",2-TKO® 25 Yes Yes — U.L.listed steel boxes are acceptable soov 232SM — 8-1/2",4-TKO® 2-1/2",2-TKO® 25 Yes Yes IIIIIIII for use in 2-hour fire rated walls. 233 — 8-1" 3-1/2",2-3/4" 25 No No — For additional information,consult U.L."Fire Resistance Directory"or 8233 — 8-1" 3-1/2",2-3/4" 25 No No 11111111 the U.L.website at www.ul.com soov 911-3 — 8-1/2",4-TKO® 3-1/2",2-TKO® 25 No No — soov Per U.L.514-A,suitable for use without a bonding jumper in circuits 0 4714,THE INSIDER® will secure nonmetallic sheathed cable in 1/2"KO(See pg.B87) up to 600 volts RACO 49 4" SQUARE BOXES 16721 1.6.C.4 2-1/8" DEEP/CONDUIT Applications . _ .f Boxes are installed in walls or cell- IP i' --i - W ings for lighting fixtures,switches , !+�.. i M1 :• X or receptacles - . • . • • , • • mH Square boxes are used where multi- I' . J W pie conductor runs are split into two 232H,232HS 232HWP 232M t'235,8235 W> or more directions to bring power to W H c) a number of electrical devices O Co Product Features 1; v Reference Box Selection section in the �. ,,: ,. a front of this catalog for complete de r, :' ; . IF scription of bracket types and features )111. P . ' • BOX-LOC®(MSBracket Box is a snap • to install. Place the bracket on the ' . iSir open side of the stud first.Slots in the S .1, bracket engage the lip of the stud and 236 37 238 251 • 911-4 actually crimp it as you press the brack- BOX-LOC® et on the stud.Barbed hooks dig into the flat side of the stud,quickly locking ORDERING INFORMATION - DIMENSION it in place Combination screw heads provide for 4"SQUAR'2-1/8"DEEP—WELDED WITH CONDUIT KO'S—30.3 CUBIC INCHES faster installation _ TKO®knockouts offer greater flexibili- CATALOG DESCRIPTION KNOCKOUTS STD. UBS RSD. PIG- UPC ty with RACO®patented combination NUMBER BRACKET& SIDES BOTTOM PKG. SUP- GRND. TAIL BAR 1/2"and 3/4" knockout SETBACK PORT PRVSN. CODE COND. COND. UBS Support-Welded to box,preset 232H HM Brkt 8-1/2",4-TKO® 2-1/2",2-TKO® 25 Yes Yes Yes — bend points to work with wall thick- ness 2-1/2"to 6" 232HS* HM Brkt 8-1/2",4-TKO® 2-1/2",2-TKO° 25 Yes Yes Yes — Red boxes,covers and extensions for 232HWP HM Brkt 8-1/2",4-TKO® 2-1/2",2-TKO® 25 Yes Yes No — dedicated life safety alarm circuits soov 232M HM Brkt 8-1/2",4-TK0® 2-1/2",2-TK0® 25 Yes Yes Yes — 4"SQUARE BOXES soov 235 TS,flush 6-1/2",3-TKO® 3-1/2",2-TKO® 25 — — No — ~0 r O. 8235 TS,flush 6-1/2",3-TKO® 3-1/2",2-TKO® 25 — — No IIIIIIII Cl 3-3/9 soov 236 FM,flush 6-3/4" 1-1/2",4-3/4" 25 — — No 11111111 A 600V 237 FM,flush 6-1/2",3-TKO® 3-1/2",2-TKO® 25 — — No 11111111 0 238 BOX LOC° 6 1/2",3 TKO° 3-1/2",2 TKO° 25 Plastic — No IIIIIIII '° ° (MS)flush m Co 0 0 0 00 ° �- 0 — — — —\' /‘- 0 ° 0 0 251 B Brkt 6-1/2",3-TKO® 3-1/2",2-TK0® 25 — — No — a 1 911-4 FM,flush 6-1/2",3-TKO® 3-1/2",2-TKO® 25 No #8-32 TAP *Box has stranded pigtail assembled ]_ EJ 2-HOLES Compliances DIMENSIONS 0 — File E195978 CATALOG A B C NUMBER (INSIDE) All RACO®single gang,two gang,4" 232H,232HS 2-1/8" 3-1/4" 4-5/16" square,and single gang gangable U.L. 232HWP 2-1/8" 3-1/4" 4-5/16" listed steel boxes are acceptable for 232M 2-1/8" 3-1/4" 4-5/16" use in 2-hour fire rated walls.For additional information,consult U.L. 235,8235 2-1/8" 7" 4-5/16" "Fire Resistance Directory"or the 236 2-1/8" 7-5/8" 4-3/8" U.L.website at www.ul.com 237 2-1/8" 7-5/8" 4-3/8" soov Per U.L.514-A,suitable for use 238 2-1/8" 4-5/8" 5-1/2" without a bonding jumper in circuits - up to 600 volts 251 2-1/8" 1-31/32" 6" 911-4 2-1/8" 7-5/8" 4-3/8" 0 4714,THE INSIDER®will secure nonmetallic sheathed cable in 1/2"KO(See pg.B87) A52 16721 1.6.C.4 STEEL CONCRETE RINGS ,..,„_ _,__,, Applications /r „,. ., ,,,___,,�'� �' ,„ . ____,___ pprafte x • Concrete rings are used with �O t_ ' ,=, ,..... i-,, �� °m rn poured deck (floor) in high-rise ���1� ��� —��� , l� 0� w w construction ��-I�'� `; ,--' �1.•••_---"-.0 H V • These boxes are installed on O °a wooden or steel concrete forms. 273, 274, 275, 284 *280 SHOWN O After the forms are removed, the 276, 279 GORILLA-RING'" WITH 918 BARS a box is flush with the concrete • RACO®Ceiling Fan Concrete n vo �/. Ring 284 is listed for support • 0� 0((((�� Pn of ceiling fans n Product Features `J i ®° �° • Flat sides provide excellent 890 891 892 893 contact for locknuts • External ears are used to nail ORDERING INFORMATION - DIMENSIONS the ring to the wood form • The top cover is removable CONCRETE RINGS for before-pour work MAX. RECOMMENDED • Ears on inside of box areSUPPORT LOADS CATALOG DEPTH KO SIZES NO. CU. STD. UPC CEILING FAN FIXTURE for fixtures NUMBER ROWS KO's IN. PKG. BAR CODE (DYNAMIC) (STATIC) ) • Waxed fixture ears prevent LBS. LBS. concrete from interfering with 270RAC 2" 1/2" &3/4" Single 24.5 25 — No 50 — the threads 271 2-1/2" 1/2" &3/4" Single 30.8 25 — No 50 • Variety of cover plates 272 3" 1/2" &3/4" Single 37.0 25 — No 50 are available 277 3" 3/4" & 1" Single 37.0 25 — No 50 273 3-1/2" 1/2" &3/4" Double 43.0 20 — No 50 • Cover plate must be ordered 278 3-1/2" 3/4" & 1" Single 43.0 20 — No 50 separately with all (except 280 — 274 a° 1/2° &3/4° Double 49.3 20 — No 50 which includes a 891 cover) Y79 4" 3/4" & 1" Double 49.3 20 — No 50 RACO®concrete rings 275 5" 1/2" &3/4" Double 61.5 10 — No 50 Compliance 276 6" 1/2" &3/4" Double 74.0 10 — No 50 uL — File E195978 284 4" 1/2" &3/4" Double 49.3 6 — 35 75 HUNG CEILING BOX — 3-1/2" DEEP CATALOG DESCRIPTION CU. STD. UPC NUMBER IN. PKG. BAR CODE 280 3/8" Stud, 8-1/2", 8-3/4" KO's* 43.0 20 918 30" Long bars for hung ceiling box — 40 `Order bars separately STEEL CONCRETE RINGS CONCRETE RING — BACK PLATES/COVERS AND ADAPTER RING #8-32 SCREWS CATALOG O.D. STD. UPC ASSEMBLED NUMBER DESCRIPTION KNOCKOUTS DIAM. PKG. BAR CODE A 890 3-1/2", 2-3/4" 4-1/2" 25 Bo B �a^� + 891 3/8" Stud 2-1/2", 2-3/4" 4-1/2" 25 Do Do 0 1"JJl^P t 892 Flat, blank — 4-1/2" 25 — A I A „U f Joins Oct. Ext. ring to concrete ring �/r it 893 4 1/2" 50 Includes two retained screws B B A KNOCKOUT LOCATIONS 3-1/2" KNOCKOUT A B SIZE 1/2" and 3/4" KOs 1/2" 3/4" 3/4" and 1" KOs 3/4" 1" oi RACO® B22 Channel 16721 1.6.C.4 B22 • Thickness: 12 Gauge (2.6 mm) • Standard lengths: 10' (3.05 m) &20' (6.09 m) • Standard finishes: Plain, DURA-GREENTM, Pre-Galvanized, Hot-Dipped Galvanized, Stainless Steel Type 3U4 or 316, Aluminum • Weight: 1.90 Lbs./Ft. (2.83 kg/m) 15/8" 3/8" (41.3) 3/8" (9.5) 77/8"7 (9.5) \\ IT (22.2) 9/32" Y j (7.1) \ 15/8" X X \ \ (41.3) .7252 \ \\ (18.4) 13/16" (20.6) SECTION PROPERTIES X - X Axis Y- Y Axis 47, Areas of Moment of Section Radius of Moment of Section Radius of ��- Channel Weight Section Inertia (I) Modulus (S) Gyration (r) Inertia (I) Modulus (S) Gyration (r) lbs./ft. kg/m sq.in. cm2 in.4 cm4 in.3 cm3 in. cm in:4 cm4 in.3 cm3 in. cm (j B22 1.910 (2.84) .562 (3.62) .1912 (7.96) .2125 (3.48) .583 (1.48) .2399 (9.99) .2953 (4.84) .653 (1.66) °il B22A 3.820 (5.69) 1.124 (7.25) .9732 (40.51) .5989 (9.81) .931 (2.36) .4798 (19.97) .5905 (9.68) .653 (1.66) B22X 6.649 (9.89) 1.956 (12.62) 4.1484 (172.67) 1.7019 (27.89) 1.456 (3.70) 1.1023 (45.88) 1.2027 (19.71) .751 (1.91) Calculations of section properties are based on metal thicknesses as determined by the AISI Cold-Formed Steel Design Manual. C) Y t 15/8" (41.3) 31/4„ X X (82.5) Y y 141i 13/16" (20.6) B22A 15/8" Wt. 3.80 Lbs./Ft. (5.65 kg/m) (41.3) Reference page 14 for general fitting and standard finish specifications. B-Line by E_'i•N 20 Strut Systems B52 Channel & Combinations B52 16721 1.6.C.4 • Thickness: 12 Gauge (2.6 mm) • Standard lengths: 10' (3.05 m) &20' (6.09 m) • Standard finishes: Plain, DURA-GREENTM, Pre-Galvanized, Stainless Steel Type 304 or 316, Hot-Dipped Galvanized • Weight: 1.27 Lbs./Ft. (1.89 kg/m) 15/8" 3/8,, -4 (41.3) 3/8,, \ (9.5)-1.- 7 7/8 1-IP - (9.5) \iiiii (22.2) 9/32" 13/16" _t 4 (7.1) \ (20.6) X X t L. �Y 4 13/16" .3366 (8.5) (20.6) co SECTION PROPERTIES X - X Axis Y- Y Axis c 0 47. Areas of Moment of Section Radius of Moment of Section Radius of co 10_ Channel Weight Section Inertia (I) Modulus (S) Gyration (r) Inertia (I) Modulus (S) Gyration (r) E lbs./ft. kg/m sq.in. cm2 in.4 cm4 in.3 cm3 in. cm in:4 cm4 in.3 cm3 in. cm 0 0 B52 1.313 (1.95) .386 (2.49) .0320 (1.33) .0673 (1.10) .288 (.73) .1404 (5.84) .1728 (2.83) .603 (1.53) al B52A 2.627 (3.91) .773 (4.99) .1517 (6.31) .1868 (3.06) .443 (1.13) .2809 (11.69) .3457 (5.67) .603 (1.53) d c Calculations of section properties are based on metal thicknesses as determined by the AISI Cold-Formed Steel Design Manual. co t 0 \4IIIIISv 1.241 (31.5) N Y Nk iiii \ 12/16" 27/16" \ 31/4" \ , , (20.6) �� X (41.3) \\ �� \ � (82.5) 15/8" \ 15/8" � (41.3) (41.3) Y �1 1 Y Y 13/16"1.- 13/16"_w- 13/16"-w (20.6) �5/8„ (20.6) �/� (20.6) (41.3) 15/8" (41.3) (41.3) B52A B52B3 B52B4 Wt. 2.54 Lbs./Ft. (3.78 kg/m) Wt. 3.81 Lbs./Ft. (5.67 kg/m) Wt. 5.08 Lbs./Ft. (7.56 kg/m) Reference page 14 for general fitting and standard finish specifications. B-Line by E_T•N 32 Strut Systems Fiberglass BFP22 THRU BFV22SH 16721 1.6.C.4 • Channel lengths: 10 Ft. (3.05 m)and 20 Ft. (6.09 m) • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. i B i � , /� BFP22 BFP22H17/8L BFP22SH � BFV22 BFV22H17/8 BFV22SH Solid Back 9/16" (14.3) holes 9/16" (14.3)x 7/8" (22.2) slots 17/8" (47.6) on centers 2" (50.8) on centers Description Weight 13/16" kg/m (20.6)7 BFP22* Polyester Resin Solid Back Gray .63 (.94) ri 1 BFV22* Vinyl Ester Resin Solid Back Beige .63 (.94) 15/8„ BFP22H17/8* Polyester Resin Holes in Back Gray .60 (.89) (41.3) BFV22H17/8* Vinyl Ester Resin Holes in Back Beige .60 (.89) Li_ i BFP22SH* Polyester Resin Slots in Back Gray .61 (.91) I BFV22SH* Vinyl Ester Resin Slots in Back Beige .61 (.91) 15/8"_„,j * Insert -10 for 10'-0" (3.05 m) length or-20 for 20'-0" (6.09 m) length (41.3) BFP22A BFV22A13/16" • Channel Lengths: 10 Ft. (3.05 m) and 20 Ft. (6.09 m) (20.6)7 • Fiberglass strut meets specification of ASTM D-4385 Levels III and IV. 15/8" 41BFP22A (41.3) BFV22A 31/4" Solid Back toF (82.5) Back Part No. Material Description Color Weight Lbs./ft. kg/m BFP22A* Polyester Resin Back To Back Gray 1.15 (1.71) 15,8„_sj BFV22A* Vinyl Ester Resin Back To Back Beige 1.15 (1.71) (41.3) * Insert -10 for 10'-0" (3.05 m) length or-20 for 20'-0" (6.09 m) length WARNING: Appropriate protective clothing and respiratory Published design loads on page 185 are based on protection device should be worn when field usage at 70°F(21°C)and must be reduced for cutting or grinding fiberglass. continuous exposure to higher temperatures. Refer to the chart below for high temperature applications. Temperature Design Load Multiplier Field Cutting Sealant Kits 75°F (24°C) 100% RSK010 Pint Sealing Kit (473 cm3) 125 1000F (52 E (52°C) 7890% (52°C) 78/o includes sealant and brush applicator —150°F (66°C) 68% • Seals exposed fibers after field cutting. • 175°F (79°C) 60% • UV resistant • 200°F (93°C) 52% Reference page 182 for general fitting specifications. B-Line by E_T•N 184 Strut Systems Channel Nuts 16721 1.6.C.4 Note: See page 50 for resistance to j slip&page 51 for pull-out strength. cotO 700 "o 00) Series Series 00) SPRING NUT d Size Fits Channel Sizes Nut Thickness Wt./C Lbs. kg N721 #8-32 B11 & B12 1/4" (6.3) 7.0 (3.17) N221 #8-32 B22, B24, B26, B32 1/4" (6.3) 7.0 (3.17) N521 #8-32 B42, B52, B54, B56 1/4" (6.3) 7.0 (3.17) N727 #10-32 B11 &B12 1/4" (6.3) 7.0 (3.17) N227 #10-32 B22, B24, B26, B32 1/4" (6.3) 7.0 (3.17) N527 #10-32 B42, B52, B54, B56 1/4" (6.3) 7.0 (3.17) N722 #10-24 B11 &B12 1/4" (6.3) 7.0 (3.17) N222 #10-24 B22, B24, B26, B32 1/4" (6.3) _ 7.0 (3.17) N522 #10-24 B42, B52, B54, B56 1/4" (6.3) 7.0 (3.17) N724 1/4-20 B11 &B12 1/4" (6.3) 6.7 (3.04) N224 1/4-20 B22, B24, B26, B32 1/4" (6.3) 6.7 (3.04)1 N524 1/4-20 B42, B52, B54, B56 1/4" (6.3) 6.7 (3.04) N723 5/16-18 B11 &B12 1/4" (6.3) 6.7 (3.04) N223 5/16-18 B22, B24, B26, B32 1/4" (6.3) 6.7 (3.04) N523 5/16-18 B42, B52, B54, B56 1/4" (6.3) 6.7 (3.04) N728 3/8-16 B11 &B12 3/8" (9.5) 9.3 (4.22) N228 3/8-16 B22, B24, B26, B32 3/8" (9.5) 9.3 (4.22) N528 3/8-16 B42, B52, B54, B56 3/8" (9.5) 9.3 (4.22) N726 7/16-14 B11 & B12 3/8" (9.5) 8.8 (3.99) N226 7/16-14 B22, B24, B26, B32 3/8" (9.5) 8.8 (3.99) N526 7/16-14 B42, B52, B54, B56 3/8" (9.5) 8.8 (3.99) N725 1/2-13 B11 &B12 1/2" (12.7) 11.6 (5.26) N225 1/2-13 B22, B24, B26, B32 1/2" (12.7) 11.6 (5.26) N525 1/2-13 B42, B52, B54, B56 3/8" (9.5) 8.8 (3.99) n N755 5/8-11 B11 & B12 1/2" (12.7) 16.4 (7.44) m N255 5/8-11 B22, B24, B26, B32 1/2" (12.7) 16.4 (7.44) 3 N555 5/8-11 B42, B52, B54, B56 3/8" (9.5) 10.2 (4.62) m N775 3/4-10 B11 & 612 1/2" (12.7) 14.5 (6.58) c N275 3/4-10 622, B24, B26, 632 1/2" (12.7) 14.5 (6.58) y N575 3/4-10 B42, B52, B54, B56 3/8" (9.5) 8.8 (3.99) co N778 7/8-9 B11 &612 1/2" (12.7) 12.5 (5.67) d N278 7/8-9 B22, B24, B26, B32 1/2" (12.7) 12.5 (5.67) a a Metric Threads m BMS-6L M6 x 1 B11 & B12 1/4" (6.3) 6.9 (3.13) al BMS-6M M6 x 1 B22, B24, B26, B32 1/4" (6.3) 6.9 (3.13) BMS-6S M6 x 1 B42, B52, B54, B56 1/4" (6.3) 6.9 (3.13) BMS-8L M8 x 1.25 B11 & B12 1/4" (6.3) 6.7 (3.04) BMS-8M M8 x 1.25 B22, B24, B26, B32 1/4" (6.3) 6.7 (3.04) BMS-8S M8 x 1.25 B42, B52, B54, B56 1/4" (6.3) 6.7 (3.04) BMS-10L M10 x 1.5 B11 & B12 3/8" (9.5) 9.6 (4.35) BMS-10M M10 x 1.5 B22, B24, B26, B32 3/8" (9.5) 9.6 (4.35) BMS-10S M10 x 1.5 B42, B52, B54, B56 3/8" (9.5) 9.6 (4.35) BMS-12M M12 x 1.75 B22, B24, B26, B32 3/8" (9.5) 9.2 (4.17) BMS-12S M12 x 1.75 B42, 652, B54, 656 3/8" (9.5) 9.2 (4.17) BMS-D-12L M12 x 1.75 B11 &B12 1/2" (12.7) 12.2 (5.53) BMS-D-12M M12 x 1.75 B22, B24, B26, B32 1/2" (12.7) 12.2 (5.53) Note: For mini channel nut information see page 203. Reference page 44 for general fitting and standard finish specifications. -Line Strut Systems ! 47 by ETN 16721 1.6.C.4 II' U N I STRUT® 1%"Framing System—Nuts&Hardware CHANNEL NUT WITH SPRING Part Nut Size Wt1100 pcs Number Thread Lbs(kg) Use With P1006-0832 #8 -32 7(3.2) P1006-1024 #10 -24 7(3.2) P1006-1420 1/4" -20 7(3.2) P1000, P1100, P1007 5/6" -18 6(2.7) P2000, r P1008 %" -16 10(4.5) _ P3000 P1009 '/,s" -14 9(4.1) P1010 '/z" -13 12(5.4) MATERIAL FINISHES Unistrut channel nuts are manufactured from mild steel bars, Nuts, bolts and washers are electro-galvanized (EG), and after machining operations are completed,they are case ASTM B633 Type Ill SC1 finish, unless otherwise noted. hardened, assuring positive biting action into the inturned Many hardware items are also available in stainless steel. Con- edge of the Unistrut channel. suit factory for ordering information. Bolt Size Channel Nut ASTM '/4"&5/6" A1011 SS GR45 3/8',7/6"&'/2' A576 GR1015 Modified 1/4"&1/4" A36 or A675 GR60 '/8" A36 Project: Approval Stamp: Architect/Engineer: Date: Phone: Contractor: Address: Notes 1: Notes 2: 9/12/08 16721 1 .6.C.4 Superstrut -- Threaded Products & Hardware4 Nuts & Bolts A-100 Regular E-142 Hex Head E-150-S Spring Nut Cap Screw � lll>lI Lag Bolt Screw \��♦ Sizes:1/2",5/,fi',3/8",'/2', ® II,5/n,3/"&/n Sizes:'/4 x 1',Y4"x 1'/2", Size:1/4"&'/2' �\\ _CO) 8 4 B 3/8"x 1" 3/8"x 1'/2','/2"x 15/,6 \ Nut is square over%"size. ' &'/2'x 11/2" Drill Size:''/4'&1"/32" ROI For all"A"and"C"series v See price sheet for additional sizes. y channel and inserts. • E-151-D Wood Screw Drive Pim AB-100 ®,, E-145 Standard Hex Nut - Size A:'/4' A Springless Nut J Sizes:'/4 ,3/8','/2 ,5/8',3/4 , G��� cb Pah - Size B:2" • Sizes:1/2",%6",3/8",/2 , �g®y� /8"&1" 0 I~B~` 14,1 %"&3/4" IMO GoldGalv®Finish. i ./ - Max.Rec.Load:100 lbs. Nut is square over''/2'size. wt For use with all channels. Silver Electroplated Finish. _ E-146 Standard Square Nut ES-142 Seismic v� �, , - Sizes:W,5/,6',3/8",'/2'&5/8" Stiffner Nut W • my - GoldGalv®Finish. ,/ - Size:ES 142'/2 x 1'/2" ` i AC-100 Springless Nut1116. - Bolt Dia.:1/2" �► Sizes:A",3/6",'/2',%"&3/4" _40:=11 I E-147 Flat Steel Washer Nut is square over 1/2"size. Sizes:1/2",1/46',3/8",'/2', ES-145 Swivel Nut ® i M For all"A","C","E"and"H"series - 5/8",3/4'&'/8" (2 and Jam Nut to" channel and inserts. GoldGalv®Finish. Combinations ®�/ y • Sizes:%"&'/2' We CO B-100 Short laTiE-148 Lock Washer - GoldGalv®Finish. Spring Nut Sizes:W,3/8",'/2'&5/6° ka E* GoldGalv®Finish. H-100 Long Sizes:W,Ym",3/6"&IA" Spring Nut ®d 13, Nut is square over 1X"size. v' vFor all"B"series channel Sizes:3 ' '/2"&%" ® �v and inserts. E-149 Slotted Hex �� �v� v Indented Head !=�� Nut is square over/2'size. ..-,..0- - - _ Machine Screw u For all"E"and"H"series u - channel and inserts. CM-100 Nylon Sizes:Y4'x Y." Y4"x 1", u Cone Nut 5/s'X 11/4'&3/6°x 11/4' • Sizes:1/2',3/6",*1/2UC-100 Universal A &••1006'/2' Nylon Cone Nut !rl For all 1%"channel. 41n110 IMO "Will not fit"B"series channel. Sizes:'/4',3/8"&''/2' "'For"B"Series channel. For all 15/8"&1'/2'channels. IMO GoldGalv®Finish. May be used with ALL strut depths.Can be used for CM-100, A-100,B-100&AB-100 Series. GoldGalv®Finish. www.tnb.com R 16721 1.6.C.4 Porteous Fastener Company Product Information Sheet Threaded Rod, Inch Series I'l�� 1ti►l!itM$1111110M111#11140$tN10111M11,100 ➢ PFC Product Categories: 00170, 00171 & 00179. ➢ Typical Material: Low Carbon Steel ➢ Material and Mechanical Properties: Purchased to meet ASTM A307 Grade A. ➢ Zinc Plating: Purchased to meet ASTM F1941 FeZn3A 1 ,. , a 1 •I■ A■ ➢ Hot-Dip Galvanized: Purchased to meet ASTM A153. ➢ Threads: Commercial nut fit similar to Class 1A.\us ➢ Typical Hardness: HRB 70-100 ➢ Tensile Strength: 60,000 PSI Min Tensile Strength (NC Threads) Tensile Strength (NF Threads) Size PSI Pounds Size PSI Pounds T/4-20 60,000 1900 1/4-28 60,000 2180 5/16-18 60,000 3100 _ 5/16-24 _ 60,000 3480 3/8-16 60,000 4650 3/8-24 60,000 5270 7/16-14 60,000 6350 _ 7/16-20 60,000 7120 1/2-13 60,000 8500 1/2-20 60,000 9600 9/16-12 60,000 11,000 _ 9/16-18 60,000 12,150 5/8-11 60,000 13,550 5/8-18 60,000 15,350 3/4-10 60,000 20,050 3/4-16 60,000 22,400 7/8-9 60,000 27,700 7/8-14 60,000 30,500 1-8 60,000 36,350 _ 1-12 _ 60,000 39,800 11/8-7 60,000 45,800 1-14 60,000 40,700 11/4-7 60,000 58,150 _ 11/8-12 60,000 51,400 13/8-6 60,000 69,300 11/4-12 60,000 64,400 11/2-6 60,000 84,300 13/8-12 60,000 78,900 13/4-5 60,000 114,000 11/2-12 60,000 94,900 2-41/2 60,000 150,000 Porteous Fastener Company Page 1 of 1 The information presented is believed to be accurate at the time of document creation.However,Porteous Fastener Company is not responsible for any claim traceable to any errors(typographical or otherwise)as contained herein.Porteous Fastener Company makes no warranties as to the accuracy of this information. Threaded Rod I Steel, Brass, Aluminum, Bronze I AATProd Page 1 of 2 16721 1.6.C.4 HOME ABOUT US THREADED ROD STUDS ANCHOR BOLTS U-BOLTS COUPLING NUTS SPECIALS CONTACT US NEWS&MEDIA A . U.S.Steel Threaded Rod Manufacturers File Trade Case search... l� ALL AMERICA All America Threaded Products,Inc. THREADED PRODUCTS, ..,a prime U.S.manufacturer of a wide range of quality threaded products. THREADED ROD Threaded rod refers to a straight,relatively long metal rod used in a variety of applications and industries ranging from plumbing, electrical,automotive,heavy construction,HVAC,fire sprinklers,telecom and food service. Single end and double end threaded rod are often bent to make specialized fasteners such as anchor bolts and u-bolts.A common type of threaded rod is all thread or fully threaded rod,where the thread extends the complete length of the rod. MATERIALS: FINISHES: THREADS: • Low Carbon Steel • Plain/Oil • Coarse(right&left hand) • T304/T316 Stainless • Clear Zinc Plated • Fine(right&left hand) • ASTM A 193 B7 • Yellow Zinc Plated • Metric ' • Brass • Hot Dip Galvanized • Acme • Aluminum • Black Oxide • Silicon Bronze • Nickel Plated SIZE RANGE: • Diameters: 2-56 to 2" • Lengths: 1'to 12' • Tube Quantities: 1 to 50 depending on diameter STOCKED STOCKED TUBE WEIGHT DIAMETERS LENGTHS QUANTITIES FT/LBS .036 6-32 3',6' 50 8-32 3',6' 50 .054 10-32 3',6' 50 .075 1/4"-20 2',3',6',10',12' 50 .119 5/16"-18 2',3',6',10',12' 35 .193 3/8"-16 2',3',6',10',12' 25 .284 7/16"-14 2',3',6',10',12' 17 .392 1/2"-13 2',3',6',10',12' 12 .520 9/16"-12 2',3',6',10',12' 10 .666 3/4"-10 2',3',6',10',12' 5 1.214 71$-8 2',3',6',10',12' 2 2.199 1-1/8"-7 2',3',6',10',12' 1 2.776 1-1/4"-7 2',3',6',10',12' 1 3.498 1-3/8"-6 2',3',6',10',12' 1 4.196 1-1/2"-6 2',3',6',10',12' 1 5.075 1-3/4"-5 2',3',6',10',12' 1 6.886 2"-4-1/2 2',3',6',10',12' 1 9.05 http://www.aatprod.com/index.php/threaded-rod 9/17/2013 A3 _ z. /- ,ilii ,�.:':' `,,,f 16721 1 .6.0.4 �������® i , A Zinc Concrete Slab Inserts, Elbows and Plugs \ ‘ , 4 Zinc Concrete Slab Inserts, Elbows and Plugs • I. 0 10 ilk Standard Finish ° • Natural • Rat , Compliances I/ ' • UL Listed NO Esq • CSA Certified O"". Sample Specifications Applications • Concrete Slab Inserts shall be die cast Zinc Alloy*ZAMAK Cb • Permits in-slab ceiling drops and floor mounts in poured 3.All conduit stops shall be coined and free of rough .�T concrete edges.Service Entrance Fittings shall be Red•Dot®Catalog Cb No. • Provides flush threaded conduit hub for mounting, pulling and future access to conduit systems Certified by the American Die Casting Institute 0 • Design permits prefabrication of in-slab conduit system Old Way imigi Features/Benefits 00 • Flush design leaves no broken or bent stubs for easyp;' ' •• • :=•"' ':• CD removal of undamaged forms ' • Flush design permits simplified in-slab work M Conduit running in a cement slab is bent 90°to run through a hole drilled a. • Flush design leaves a neat,uncluttered job in the form.Drilling takes time and damages the form.Stripping form often n • Offered in straight ES configuration for straight through damages conduit stubs.Varying length of stubs requires individual measuring 0 and cutting of conduit drops. IIC conduit runs and mounting of floor boxes in slabs over 6" Red•Dor Way thick CA • Offered in ESL configuration to eliminate bending of i conduit in slabs over 4" thick :' :• 6"■ ...:7,. .......;.......,.. 6"Slab 4"Slab • Precision cast and machined surfaces permit safer wire :" : n „—f pulling •--1- ESL ES • ZAMAK 3 Zinc can be embedded in concrete Conduit running in a cement slab is attached to a 90°concrete slab insert, Standard Material or conduit is bent 90°and is threaded to a straight insert.Nail or screw fitting • Die cast zinc alloy ZAMAK 3. Certified by the Certified Zinc to wood or metal forms.After concrete is poured and forms stripped,conduit Alloy Plan (CZAP) drops quickly into fittings from floor below. Drops are easily measured from ceiling line to switch or outlet height and cut in uniform lengths. Threaded Rigid/IMC Conduit Inserts ES1 ESL I- Concrete slab inserts permit in-slab ceiling drops and floor mounts in poured concrete. 6°Slab 4..Slab _�' • For Rigid and IMC -1— 7- ' • Slab insert is nailed to form prior to pour a CAT.NO. HUB SIZE • Removable seal keeps threads cement free owe... - pok Straight • ESL eliminates: ES-1 /° �w1,ry/ ES-2 V," —Bends in 4" concrete slabs ! ES-3 1" —Damage to form ...., 90� ESL-1 �" —Cutting off conduit stubs ' "� ESL-2 • UL®Listed, CSA Certified ".— ESL-3 1" www.tnb.com R " 7,, ..a.rir ,,--,N. Red•Dot 16721 1.6.C.4 Inc Concrete Slab Inserts, Elbe s and Plugs Elb;n: ws and Plugs Fema • to Female Aluminum Elb 1 s ES D..11.y r o a Fi cb _ \-„.._,.............„,,,„, z.- VS N ES CQ CP CAT.NO. CAT.NO. HU IZE CAT.NO. CAT.NO. HUB SIZE CAT.NO. SIZE A B C D E oc ES-1 %" 119/6 1Y6 12%2 11/22 1/4 Corner Pulling 211/6 15 131 '/ / 1 Ca 3 Rigid IMC EMT Rigid MC EMT ES 3 14" 29/,6 2 25/+6 1% %4 4.4 ACE-1 BCE-1 AP -1 BPEF-1 'A" OACE-2 BCE-2 %" Ar F-2 BPEF-2 5" • • ' E and BCE Close Up Plugs — Zinc . do ° T o o RI asIl D a c ° 1 a CAT.NO. COLOR HUB SIZE F-n U- PLG-1-RD Silver /" - ACE PLG-2-RD Silver1,1 m. i PLG-3-RD Silver 1" D-PAK®* SIZE A B 2% 18 CAT.NO. COLOR HUB SIZ• %" 22'%32 15A6 DPLG-1 Silver %" DPLG-1-r• Bronze DPLG 1 WH White r" APEF and BPEF DPLG 2 Silver %" ESL F r ---- (r 1 A I. D B APEF BPEF G T C SIZE A B C A 1/ 1 I ESL 1�i. 91/6 1264 CAT.NO. SIZE A B C D E F G ESL-1 'A" 4252 34%4 32952 33/6 1'/ 152 ESL-2 %" 511/6 3252 41/2 33/32 2'/6 11/4 IA ESL-3 1" 53/2 33/4 315/,6 263/64 256 111/2 1/4 • www.tnb.com R PENTAIR LAY-IN WIREWAY LAY-IN NEMA TYPE 1 PAINTED FLAT-COVER WIREWAY 16721 1.6.C.4 LAY-IN PAINTED FLAT-COVER WIREWAY, NEMA TYPE 1 APPLICATION This painted wireway features an open design on one side so wires and cables can be laid in safely along the entire run without pulling, a practice that can damage insulation.A variety of lengths and fittings provide design flexibility. FEATURES • Flat cover design • Open top assembly • Available with or without knockouts • Keyhole screw slots on flat covers SPECIFICATIONS INDUSTRY STANDARDS • 16 and 14 gauge pre-painted steel covers and bodies UL 870 Listed; File No.E27524 FINISH cUL Listed per CSA C22.2 No.26;File No.E27524 ANSI 61 gray polyester powder paint finish inside and out. NEMA/EEMAC Type 1 IEC 60529 iii..., This drawing illustrates how most of the Hoffman NEMA Type I l —GSH lay-in wireway sections and fittings could be used in an actual wireway run.The covers have been omitted to present the lay-in feature more GT GA —GOA 1 clearly.Many different sections and GT 1 i fittings can be combined in any —G—R QOJ� —X /1i p1 configuration desired. ` �10 —G90TX • GDB \` /I ��" Mt Tol iso., %/ —TiI -90EOUT 10 + G45E , i. 90EIN `_ ¢`v, GPA t G90SE 14 w� g �' _0450 1\� GDB . —ORP OR I 87552187 —GCPNK 1 CABLE AND WIRE MANAGEMENT SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00136 I LAY-IN WIREWAY LAY-IN NEMA TYPE 1 PAINTED FLAT-COVERWIREWAY 16721 1.6.C.4 eajw Standard Product Selection Matrix I ' .00 x3.00 in. 4.00 x 4.00 in. 6.00 x 6.00 in. 8.00 x8.00 in. 10.00 x 10.00 in. 12.00 x 12.00 in. .7. i u I , I u 1 a I . 1 1111 4 4 i m I . I i i 12.00-in.(305-mm)Straight Section with knockouts F22T112GVPWK - F44T112GVPWK F66T112GVPWK F88T112GVPWK - F1212T112GVPWK 12.00-in.(305-mm)Straight Section without knockouts F22T112GVP - F44T112GVP F66T11268P F88T112GVP Fl010T112GVP Fl212T112GVP 18.00-in.(455-mm)Straight Section without knockouts - - F44T118GVP F66T11868P F88T118GVP - - 24.00-in.(610-mm)Straight Section with knockouts F22T124GVPWK - F44T1246VPWK F66T1246VPWK F88T1246VPWK - F1212T124GVPWK 24.00-in.(610-mm)Straight Section without knockouts F22T1246VP - F44T124GVP F6611246VP F88T1246VP F1010T124GVP F1212T124GVP 36.00-in.(914-mm)Straight Section with knockouts F22T136GVPWK - F44T136GVPWK F66T136GVPWK F88T1366VPWK - F1212T136GVPWK 36.00-in.(914-mm)Straight Section without knockouts F22T136GVP - F44T136GVP F66T136GVP F8811366VP F1010T136GVP F1212T136GVP 48.00-in.(1219-mml Straight Section with knockouts F22T148GVPWK - F44T148GVPWK F66T1486VPWK F88T148GVPWK - F1212T148GVPWK 48.00-in.(1219-mm)Straight Section without knockouts F22T148GVP - F44T148GVP F66T148GVP F88T148GVP F1010T148GVP F1212T148GVP 60.00-in.11524-mm)Straight Section with knockouts F22T160GVPWK - F44T160GVPWK F66T160GVPWK F88T1606VPWK - F1212T160GVPWK 60.00-in.(1524-mm)Straight Section without knockouts F22T160GVP F33T160GVP F44T160GVP F66T160GVP F88T160GVP F1010T160GVP Fl2121160GVP 72.00-in.(1829-mml Straight Section with knockouts - - F44T172GVPWK F66T172GVPWK - - - 72.00-in.(1029-mm)Straight Section without knockouts - - F44T172GVP F66T172GVP F88T172GVP F1010T172GVP - 120.00-in.(3048-mm)Straight Section with knockouts F22T1120GVPWK - F44T1120GVPWK F66T1120GVPWK F88T1120GVP -120.00-in.(3048-mm)Straight Section without knockouts F22T1120GVP F33T1120GVP F44T1120GVP F66T1120GVP F88T1120GVP F1010T1120GVP F1212T1120GVP 90°Flush Tee F22GT F33GT F44GT F66GT F88GT F1010GT F1212GT Sweep Tee F22T - F44T F66T F88T F1010T F1212T Cross Fitting F22X - F44X F66X F88X F1010X F1212X 90°Sweep Elbow F22690SE - F44690SE F66G90SE F88G9OSE F1010690SE F1212G90SE 90°Elbow-Tee-Cross F22G90TX F33G90TX F44G90TX F66G90TX F88G90TX F1010G90TX F1212G90TX 90°Elbow F22690E F33690E F44690E F66690E F88090E F1010690E F1212G90E 90°Elbow Outside Opening F2290EOUT - F4490EOUT F6690EOUT F8890EOUT F101090EOUT F121290EOUT 90°Elbow Inside Opening F2290EIN - F4490EIN F6690EIN F8890EIN F101090EIN F121290EIN 45°Elbow F22G45E F33G45E F44645E F66G45E F88G45E F1010G45E F1212G45E Telescope Fitting' F226A - F44GA F666A F88GA F1010GA F1212GA Open Adapter F22GOA - F44GOA F66GOA F88GOA F1010GOA F1212GOA Panel Adapter F22GPA F33GPA F44GPA F66GPA F88GPA F1010GPA F1212GPA Closure Plate with knockouts F22GCP - F446CP F666CP F88GCP F1010GCP F1212GCP Closure Plate without knockouts F22GCPNK F33GCPNK F44GCPNK F66GCPNK F88GCPNK F1010GCPNK F1212GCPNK Reducer - F33622R F44622R F666448 F88666R F1010688R F1212600R F44G33R F1212610100 Drop and Bracket Hanger F226DB - F44GD8 F66GDB F886DB F10106DB F1212GDB Support Hanger F22GSH - F44GSH F66GSH F88GSH F1010GSH F1212GSH Universal U-Connector F22GUC F33GUC F44GUC F666UC F88GUC F1010GUC F1212GUC Barrier Kit,bolt-on - F33BK60 F44BK60 F66BK60 F88BK60 -Each barrier 60.00 in.(1524 mm) 'Not ULicOL listed. STRAIGHT SECTION CONCENTRIC KNOCKOUTS (1-1 1/4) 4.00m X 4.00 AND 1 6.00 X 1 6.00 " \ 102mm 102mm 152mm 152mm CONCENTRIC KNOCKOUTS (1/2-3/4) C 4.00 X 4.00 SIZES ONLY CONCENTRIC 64mm 64mm KNOCKOUT 1/2-3/4) B � x I ALL SIZES) -11,11 A 0Il, I\, I I\ 87794679 F Protects electrical wiring in applications where dust,dirt,oil and water are not serious problems.All sections and fittings are 09 .ss mm completely open on one side so wires and cables can be laid in FOR83 3/4 KO FOR41/4m K0 along wireway run. No pulling through of wires or cables prevents 1 .503.00 damage to insulation that often occurs in a pull-through wiring g 38 mm _ - _ 3.oo _ _ 3.oo - 76 mm 76 mm 76 mm system.Flat cover design allows for mounting flush with walls or ceilings.Keyhole screw slots on flat covers provide easy access. - C BULLETIN:F4OFC,F40G 87794743 PATTERN REPEATS EVERY 12.00 305 mm EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 •FAX 763.422.2600•HOFFMANONLINE.COM CABLE AND WIRE MANAGEMENT 2 Spec-00136 I PENTAIR LAY-IN WIREWAY LAY-IN NEMA TYPE 1 PAINTED FLAT-COVER WIREWAY Straight Sections Number of Number of Knockouts, Knockouts, Catalog Number AxBxC in. AxBxC mm .50 in.-.75 in. 1.00 in.-1.25 in. F(in.) F Imm) X(in.) X(mm) Y(in.) Y(mm) F22T112GVPWK 2.50 x 2.50 x 12.00 64 x 64 x 305 8 - 1.06 27 3.00 76 6.00 152 F22T112GVP 2.50 x 2.50 x 12.00 64 x 64 x 305 - - - - - - - - F22T124GVPWK 2.50 x 2.50 x 24.00 64 x 64 x 610 16 - 1.06 27 6.00 152 12.00 305 F22T124GVP 2.50 x 2.50 x 24.00 64 x 64 x 610 - - - - - - - - F22T136GVPWK 2.50 x 2.50 x 36.00 64 x 64 x 610 24 - 1.06 27 6.00 152 12.00 305 F22T136GVP 2.50 x 2.50 x 36.00 64 x 64 x 914 - - - - - - - - F22T148GVPWK 2.50 x 2.50 x 48.00 64 x 64 x 1219 32 - 1.06 27 6.00 152 12.00 305 F22T148GVP 2.50 x 2.50 x 48.00 64 x 64 x 1219 - - - - - - - - F22T160GVPWK 2.50 x 2.50 x 60.00 64 x 64 x 1524 40 - 1.06 27 6.00 152 12.00 305 F221160GVP 2.50 x 2.50 x 60.00 64 x 64 x 1524 - - - - - - - - F22T1120GVPWK 2.50 x 2.50 x 120.00 64 x 64 x 3048 80 - 1.06 27 6.00 152 12.00 305 F22T1120GVP 2.50 x 2.50 x 120.00 64 x 64 x 3048 - - - - - - - - F33T160GVP 3.00 x 3.00 x 60.00 76 x 76 x 1524 - - - - - - - - F33T1120GVP 3.00 x 3.00 x 120.00 76 x 76 x 3048 - - - - - - - - F44T112GVPWK 4.00 x 4.00 x 12.00 102 x 102 x 305 4 4 1.62 41 3.00 76 6.00 152 F44T112GVP 4.00 x 4.00 x 12.00 102 x 102 x 305 - - - - - - - - F44T118GVP 4.00 x 4.00 x 18.00 102 x102 x 455 - - - - - - - - F44T124GVPWK 4.00 x 4.00 x 24.00 102 x 102 x 610 8 8 1.62 41 6.00 152 12.00 305 F44T124GVP 4.00 x 4.00 x 24.00 102 x 102 x 610 - - - - - - - - F44T136GVPWK 4.00 x 4.00 x 36.00 102 x 102 x 914 12 12 1.62 41 6.00 152 12.00 305 F44T136GVP 4.00 x 4.00 x 36.00 102 x 102 x 914 - - - - - - - - F44T148GVPWK 4.00 x 4.00 x 48.00 102 x 102 x 1219 16 16 1.62 41 6.00 152 12.00 305 F44T148GVP 4.00 x 4.00 x 48.00 102 x102 x 1219 - - - - - - - - F44T160GVPWK 4.00 x 4.00 x 60.00 102 x 102 x 1524 20 20 1.62 41 6.00 152 12.00 305 F44T160GVP 4.00 x 4.00 x 60.00 102 x 102 x 1524 - - - - - - - - F44T172GVPWK 4.00 x 4.00 x 72.00 102 x 102 x 1829 24 24 1.62 41 6.00 152 12.00 305 F44T172GVP 4.00x4.00x72.00 102x102x1829 - - - - - - - - F44T1120GVPWK 4.00 x 4.00 x 120.00 102 x 102 x 3048 40 40 1.62 41 6.00 152 12.00 305 F44T1120GVP 4.00 x 4.00 x 120.00 102 x 102 x 3048 - - - - - - - - F66T112GVPWK 6.00 x 6.00 x 12.00 152 x 152 x 305 4 4 1.62 41 6.00 152 12.00 305 F66T112GVP 6.00 x 6.00 x 12.00 152 x152 x 305 - - - - - - - - F661118GVP 6.00 x 6.00 x 18.00 152 x 152 x 455 - - - - - - - - F661124GVPWK 6.00 x 6.00 x 24.00 152 x 152 x 610 8 8 1.62 41 6.00 152 12.00 305 F66T124GVP 6.00 x 6.00 x 24.00 152 x 152 x 610 - - - - - - - - F66T136GVPWK 6.00 x 6.00 x 36.00 152 x 152 x 914 12 12 1.62 41 6.00 152 12.00 305 F661136GVP 6.00 x 6.00 x 36.00 152 x 152 x 914 - - - - - - - - F66T148GVPWK 6.00 x 6.00 x 48.00 152 x152 x 1219 16 16 1.62 41 6.00 152 12.00 305 F661148GVP 6.00 x 6.00 x 48.00 152 x 152 x 1219 - - - - - - - - F66T160GVPWK 6.00 x 6.00 x 60.00 152 x 152 x 1524 20 20 1.62 41 6.00 152 12.00 305 F66T160GVP 6.00 x 6.00 x 60.00 152 x152 x 1524 - - - - - - - - F66T172GVPWK 6.00 x 6.00 x 72.00 152 x152 x 1829 24 24 1.62 41 6.00 152 12.00 305 F661172GVP 6.00 x 6.00 x 72.00 152 x 152 x 1829 - - - - - - - - F66T1120GVPWK 6.00 x 6.00 x 120.00 152 x 152 x 3048 40 40 1.62 41 6.00 152 12.00 305 F66T1120GVP 6.00 x 6.00 x 120.00 152 x152 x 3048 - - - - - - - - F88T112GVPWK 8.00 x 8.00 x 12.00 203 x 203 x 305 4 4 1.62 41 3.00 76 6.00 152 F88T112GVP 8.00 x 8.00 x 12.00 203 x 203 x 305 - - - - - - - - F88T118GVP 8.00 x 8.00 x 18.00 203 x 203 x 455 - - - - - - - - F88T124GVPWK 8.00 x 8.00 x 24.00 203 x 203 x 610 8 8 1.62 41 6.00 152 12.00 305 F88T124GVP 8.00 x 8.00 x 24.00 203 x 203 x 610 - - - - - - - - F88T136GVPWK 8.00 x 8.00 x 36.00 203 x 203 x 914 12 12 1.62 41 6.00 152 12.00 305 F88T136GVP 8.00 x 8.00 x 36.00 203 x 203 x 914 - - - - - - - - F88T148GVPWK 8.00 x 8.00 x 48.00 203 x 203 x 1219 16 16 1.62 41 6.00 152 12.00 305 F88T148GVP 8.00 x 8.00 x 48.00 203 x 203 x 1219 - - - - - - - - F88T160GVPWK 8.00 x 8.00 x 60.00 203 x 203 x 1524 20 20 1.62 41 6.00 152 12.00 305 F88T160GVP 8.00 x 8.00 x 60.00 203 x 203 x 1524 - - - - - - - - F8BT172GVP 8.00 x 8.00 x 72.00 203 x 203 x 1829 - - - - - - - - F88T11206VP 8.00 x 8.00 x 120.00 203 x 203 x 3048 - - - - - - - - F1010T112GVP 10.00 x 10.00 x 12.00 254 x 254 x 305 - - - - - - - - F1010T124GVP 10.00 x 10.00 x 24.00 254 x 254 x 610 - - - - - - - - F1010T136GVP 10.00 x 10.00 x 36.00 254 x 254 x 914 - - - - - - - - F1010T148GVP 10.00 x 10.00 x 48.00 254x 254 x 1219 - - - - - - - - F1010T160GVP 10.00 x 10.00 x 60.00 254 x 254 x 1524 - - - - - - - - F1010T172GVP 10.00 x 10.00 x 72.00 254 x 254 x 1829 - - - - - - - - F1010T1120GVP 10.00 x 10.00 x 120.00 254 x 254 x 3048 - - - - - - - - F1212T112GVPWK 12.00 x 12.00 x 12.00 305 x 305 x 305 4 4 1.62 41 3.00 76 6.00 152 F1212T112GVP 12.00 x 12.00 x 12.00 305 x 305 x 305 - - - - - - - - F1212T124GVPWK 12.00 x 12.00 x 24.00 305 x 305 x 610 8 8 1.62 41 6.00 152 12.00 305 F1212T124GVP 12.00 x 12.00 x 24.00 305 x 305 x 610 - - - - - - - - F1212T136GVPWK 12.00 x 12.00 x 36.00 305 x 305 x 914 12 12 1.62 41 6.00 152 12.00 305 F1212T136GVP 12.00 x 12.00 x 36.00 305 x 305 x 914 - - - - - - - - F1212T148GVPWK 12.00 x 12.00 x 48.00 305 x 305 x 1219 16 16 1.62 41 6.00 152 12.00 305 F1212T148GVP 12.00 x 12.00 x 48.00 305 x 305 x 1219 - - - - - - - - F1212T160GVPWK 12.00 x 12.00 x 60.00 305 x 305 x 1524 20 20 1.62 41 6.00 152 12.00 305 F1212T160GVP 12.00 x 12.00 x 60.00 305 x 305 x 1524 - - - - - - - - F1212T1120GVP 12.00 x 12.00 x 120.00 305 x 305 x 3048 - - - - - - - - 3 CABLE AND WIRE MANAGEMENT SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00136 I PENTAIR 16721 1.6.C.4 LAY-IN WIREWAY LAY-IN NEMA TYPE 1 PAINTED FLAT-COVER WIREWAY CLOSURE PLATE Closes the end of a wireway section or run. F22GCP 2.5052.50 64x64 With knockouts BULLETIN:F4OPF F22GCPNK 2.50x2.50 64x64 Without knockouts F44GCP 4.00 x 4.00 102 x 102 With knockouts � F33GCPNK 3.00 x 3.00 76 x 76 Without knockouts F66GCPNK 6.00 x 6.00 152 x 102 Without c knockoutsut FbbGCP 6.00 x 6.00 152 x 152 With knockouts F66GCPNK 6.00 x 6.00 152 x 152 Without knockouts c\ B F88GCP 8.00 x 8.00 203 x 203 With knockouts J�J�� F88GCPNK 8.00 x 8.00 203 x 203 Without knockouts F1010GCP 10.00 x 10.00 254 x 254 With knockouts F1010GCPNK 10.00 x 10.00 254 x 254 Without knockouts I .75 F1212GCP 12.00 x 12.00 305 x 305 With knockouts 87797097 19 mm F1212GCPNK 12.00 x 12.00 305 x 305 Without knockouts I 'OP AND BRACKET HANGERS Drop a : .racket hangers support a wireway run. ° BULLETIN:F 0• N ° MAX. ° N max. N max. P P R R S S T T Catalog Number (in.) (mm) .) (mm) (in.) (mm) (in.) (mm) F22GDB 8.50216 11 .38 86 7.25 184 3.75 95 F44GDB 10.50 2666.00 152 4. 05 9.25 235 4.50 114 \ ° °°° F66GDB 15.11 81 7.12 181 5.12 131 3.75 349 5.50 140 F88GDB .00 533 10.81 275 7.00 178 13. 349 7.75 197 87797100 R F1010 ,: 22.00 559 13.81 335 8.38 213 13.75 3 . 10.25 260 P 2GDB 23.00 584 15.56 395 9.78 248 13.75 349 1 . I 318 T °e. eo e��9�,�o S -----H 1 SUPPORT HANGER H For floor or wall installations. Catalag s m Wain-. BULLETIN:F4OPF F22GSH 2.50 4.62 64 x 64 117 F44GSH 4.00 x 4.00 6.12 50 �38 mm 102 x 102 155 F66GSH 6.00 x 6.00 8.12 t----- 152 x 152 206 Qr �� F88GSH 8.00 x 8.00 10.12 �O 203 0 01203257 ®�M F1010GSH 10.00 x 10.00 12.12 1.00 254 x 254 308 87797102 7 25 mm F1212GSH 12.00 x 12.00 14.12 305 x 305 359 7 CABLE AND WIRE MANAGEMENT SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00136 I LAY-IN WIRE WAY LAY-IN NEMA TYPE 1 PAINTED FLAT-COVERWIREWAY f?4,0Gv UNIVERSAL U-CONNECTOR Catalog Number AxBin.lmm Joins wireway sections and fittings.Top swings aside to retain the F22GUC 2.50x2.50 lay-in feature.One U-connector required at each wireway joint 64x64 except telescope fittings,panel adapters,open adapters,closure F33GUC 3.00x3.00 plates or reducers. 76x76 F44GUC 4.00 x 4.00 BULLETIN:F4OPF 102x102 F66GUC 6.00 x 6.00 1 .38 ON 2.00 X 2.00 152x152 35mm 51mm 51mm F88GUC 8.00 x 8.00 OMD 4.00 X 4.00 102mm 102mm 203x203 6.00 X 6.00 F1010GUC 10.00 x10.00 B 152mm 152mm 254x254 2.00 ON 8.00 X 8.00 F1212GUC 12.00 x 12.00 51mm 203mm 203mm 305x305 10.00 X 10.00 254mm 254mm 12.00 X 12.00 305mm 305mm 87797099 BARRIER KIT, BOLT-ON Divides wireway into two or more compartments.Barriers are /� fastened to wireway sections with screws.Sealing washers are 59.75 / included. 1518 m BULLETIN:F20 W .25 Catalog Number AxB in./mm in./mm �'6 mm F33BK60 3.00 x 3.00 2.00 � [111ril [>- 170x76 51 25 mm F44BK60 4.00 9 4.00 3.00 102 x 102 76 F66BK60 6.00 x 6.00 4.50 152 x 152 114 --'''/A .62 877971 91 F88BK60 8.00 x 8.00 6.00 16 mm 203 x 203 152 REDUCER Catalzg Number AxB in.lmm Reduces wireway to a smaller size. F33G22R 3.00x3.00 BULLETIN:F10,F4OPF 76x76 F44G22R 4.00 x 4.00 102x102 F44G33R 4.00 x 4.00 601 x 101 F66G44R 6.00 ..10 152 B • F88G66R 8.00 x 1 203 x 203 F1010G88R 10.00 x 10.00 Y 87797098 254 x 254 F1212G88R 12.00 x 12.00 1.50 305 x 305 38 mm F1212G10 I' 12.00x12.00 305 x 305 EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 •FAX 763.422.2600•HOFFMANONLINE.COM CABLE AND WIRE MANAGEMENT 8 Spec-00136 I Scotch © Super 33+TM 16721 1.6.C.5 Vinyl Electrical Tape Data Sheet October 2014 Description Scotch®Super 33+TM Vinyl Electrical Tape is a premium grade, 7 mil thick, all-weather vinyl-insulating tape. It is designed to perform continuously in ambient temperatures up to 105°C (220°F). The tape is conformable for cold weather application down to -18°C (0°F). It has excellent resistance to abrasion, moisture, alkalies, acids, corrosion and varying weather conditions (including ultraviolet exposure). The combination of elastic backing and aggressive adhesive provides moisture-tight electrical and mechanical protection with minimum bulk. Scotch®Super 33+TM Vinyl Electrical Tape is UL Listed and is a Canadian Standards Association (CSA) Certified "Insulating Tape." • UL Listed; UL 510 Standard "Insulating Tape" (product category OANZ), File E129200 • CSA Certification; Standard C22.2 No.197-M1983 "PVC Insulating Tape," File LR 48769 • Polyvinyl chloride (PVC) backing. • Pressure-sensitive rubber based adhesive. • Compatible with solid dielectric cable insulations. • Compatible with rubber and synthetic splicing compounds, as well as epoxy and polyurethane resins. • Inhibits corrosion of electrical conductors. • For indoor or outdoor applications. Applications • Primary electrical insulation for all wire and cable splices rated up to 600 volts and up to 105°C (220°F). • Primary electrical insulation for 600 volt bus applications, and protective jacketing for low and high voltage bus. • Protective jacketing for high voltage cable splices and repairs. • Harnessing of wires and cables. Specifications Scotch®Super 33+TM Vinyl Electrical Tape is based on polyvinyl chloride (PVC) and/or its copolymers and has a rubber-based, pressure-sensitive adhesive. The tape shall be 7 mils thick, and be UL Listed and marked per UL Standard 510 as "Flame Retardant, Cold and Sunlight Resistant."The tape must be applicable at temperatures ranging from 0°F through 100°F (-18°C through 38°C)without loss of physical properties. The tape shall be classified for use in both indoor and outdoor environments. The tape shall be compatible with synthetic cable insulations,jackets and splicing compounds. The tape will remain stable and will not telescope more than 0.1 inches when maintained at temperatures below 120°F (50°C). 1 of 3 Scotch® Super 33+TM Vinyl Electrical Tape Agency Approvals • UL Listed; UL 510 Standard "Insulating Tape" (product category OANZ), &Self Certifications File E129200 • CSA Certification; Standard C22.2 No.197-M1983 "PVC Insulating Tape," File LR 48769 • Meets A-A-55809 For RoHS information, please visit www.3M.com/ROHS Typical Properties Not for specifications. Values are typical, not to be considered minimum or maximum. Properties measured at room temperature 73°F (23°C)unless otherwise stated. Physical Properties Typical Value US units(metric) Temperature Rating- UL 510 176°F (80°C) CSA -C22.2 No. 197-M1983 handling 0°F(-18°C) continuous operation 221°F (105°C) Color BLACK Thickness 7 mils (0.177 mm) Adhesion to Steel (ASTMD 1000) 72°F (22°C) 28 oz/in. 0°F(-18°C) 60 oz/in. Adhesion to Backing (ASTMD 1000) 72°F (22°C) 28 oz/in. 0°F(-18°C) 60 oz/in. Backing Strength (ASTMD 1000) 72°F(22°C) 15 lbs/in. Ultimate Elongation (ASTMD 1000) 72°F(22°C) 250%. 0°F(-18°C) 100% Flammability(Maximum) UL 510 1 sec. ASTM D-1000 4 sec. Accelerated Aging (ASTM D-1000) 80% Flagging (ASTM D-1000) <0.1 in. Telescoping 24 Hours @ 120°F(50°C) <0.1 in Electrical Property Typical Value US units Voltage Rating -UL 510 600V Dielectric Strength (ASTM D-1000) Standard Condition 1,150 V/mil V/mil High Humidity 90% of std. Insulation Resistance(ASTM D-1000) ( High Humidity Method) >1x106 megohms 2 of 3 Scotch® Super 33+TM Vinyl Electrical Tape Shelf Life & This product has a 5-year shelf life from date of manufacture when stored in a humidity Storage controlled storage (10°C/50°F to 27°C/80 °F and <75% relative humidity). Availability Scotch®Super 33+TM Vinyl Electrical Tape is available from your local 3M authorized distributor in the following standard roll sizes: 3/4 in. x 66 ft. 3/4 in. x 52 ft. 3/4 in. x 20 ft. Other lengths and widths are available by special request. Please contact your local distributor; available from 3M.com/electrical [Where to Buy] or call 1.800.245.3573. Engineering/ Primary electrical insulation (branch wiring in wet or dry locations): All splices for 600 volt Architectural wire rated 105°C (220°F) and below shall be insulated with a minimum of two half-lapped Specification: layers of Scotch®Super 33+TM Vinyl Electrical Tape. All connectors having irregular surfaces shall be padded with 3M TM Scotchfil TM Electrical Insulation Putty or Scotch® Linerless Rubber Splicing Tape 130C prior to insulating with Scotch®Super 33+TM Vinyl Electrical Tape. Mechanical protection (outer jacketing): All rubber and thermoplastic insulating high voltage power cable tape splices and repairs shall be overwrapped with at least two half- lapped layers of Scotch®Super 33+TM Vinyl Electrical Tape. Installation Scotch®Super 33+TM Vinyl Electrical Tape shall be applied in half-lapped layers with Techniques: sufficient tension to produce a uniform wind (for most applications this tension will reduce the tape's width to approximately 5/8 of its original width). On pigtail splices, the tape shall be wrapped beyond the end of the wires and then folded back, leaving a protective cushion to resist cut-through. Wrap tape up-hill, taping from a smaller diameter surface to a larger diameter surface. Apply the tape with no tension on the last wrap to prevent flagging. 3M, Scotch, Scotchfil and Super 33+ are trademarks of 3M Company. Important Notice All statements,technical information,and reoommndations related to 3Ms products are based on information believed to be reliable,but the accuracy or corrpleteness is not guaranteed.Before using this product,you must evaluate it and detemine if it is suitable for your intended application.You assume all risks and liability assodated with such use.My statements related to the product,which are not contained in 3Ms current publications,or any contrary statements contained on your purchase order,shall have no force or effect unless expressly agreed upon,in writing,by an authorized officer of 3M. Warranty; Limited This product will be free from defects in material and manufacture at the time of purchase.3M MAKES NO OTHER Remedy; Limited WARRANTIES INCLUDING,BUT NOT UNITED TO,ANY IMPLJED WARRANTY OF MERCHANTABIUTYOR Liability FITNESS FORA PARTICULAR PURPOSE. If this product is defective within the warranty period stated above,your exdusive remedy shall be,at 3Ms option,to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law,3M will not be liable for any indirect,special,incidental or consequential loss or damage arising from this 3M product,regardess of the legal theory asserted. 3M Electrical Markets Division 6801 River Place Blvd. Austin,TX 78726-9000 Please recycle 800.245.3573 ©3M 2014 All rights reserved FAX:800.245.0329 78-8124-4841-9 Rev D www.3M.com/electrical 3 of 3 16721 1.6.C.5 Cl) cc 0 Wing-Nut® Wire Connectors W • Three color-coded models cover a full range of wire sizes from 18 to 6 AWG Z Z • Specially designed contoured wings provide a secure grip for extra leverage on maximum 0 wire combinations • Live-action spring expands to accept wire shape and size with no pre-twisting required • Square-wire spring threads directly onto conductors for fast,secure connections to L2LIt #• Deep skirt helps protect against flash over and turned back strands for maximum 'O dielectric protection • Tough, UL 94V-2 flame-retardant shell rated at 105°C (221°F) I • UL Listed to 486C and CSA Certified to C22.2#188; comply with Federal Specification W-S-610E Model Color Wire Combination Range Wire Combination Range(mm) Quantity Cat. No. 451®ir Box of 100 30-451 600V" 600V" Jar of 225 30-451J 18 to 10 AWG ,75mm2 to 6,0mm2 Jar of 500 30-651J Yellow Min.2#18 Min.2-,75mm2 Carton of 1,000 30-551 Max.3#12 Max.3-4,0mm2 Keg of 5,000(10 bags,500 ea.) 30-651 Barrel of 35,000 30-851 452® Box of 100 30-452 600V* 600V" Jar of 300 30-452J IL7 � 18 to 8 AWG ,75mm2 to 10,0mm2 Jar of 500 30-652J Red 'Os Min.2#18 Min.2-,75mm2 Carton of 1,000 30-552 Max.4#10 Max.4-6,0mm2 Keg of 5,000(10 bags,500 ea.) 30-652 Barrel of 25,000 30-852 454' liOX 01n 3U-4b4 600V" 600V" Carton of 250 30-554 14 to 6 AWG 2,5mm2 to 16,0mm2 Blue Min.3#12 Min.3-4,0mm2 Keg of 1,000(10 bags,100 ea.) 30-654 Max.1#6&2#8 Max.2-16,0mm2 w/1-4,Omm2 Barrel of 10,000 30-854 1,000V maximum in fixtures and signs 0 wire Connector u/Cu 6® (♦ E y Greenie® Grounding Wire Connectors LISTED • Designed for making ground connections and bonding non-metallic sheathed cable • Contoured wings for maximum leverage • Live-action,square-wire spring provides superior grounding connections • Tough, UL 94V-2 flame-retardant shell • UL Listed to 467 and CSA Certified to C22.2 #188;comply with Federal Specification W-S-610E Model I Color I Wire Combination Range Wire Combination Range(mm) Quantity Cat.No. 92® Box of 100 30-092 14 to 10 2,5mm2 to 6,0mm2 Jar of 150 30-092J Green Min.2#14 Min.2-2,5mm2 Carton of 1,000 30-192 Max.4#12 Max.2-4,0mm2 w/1-2,5mm2 Keg of 5,000(10 bags,500 ea.) 30-292 Barrel of 25,000 30-992 Greenie®Grounding Connector fully meets the intent of the N.E.C.and specifically aids in 0 GG5oundConnector CU/CU /u ® compliance with the following: Y LISTED ARTICLE 250:GROUNDING 250-146 Connecting Receptacle Grounding Terminal to Box 250-148 Continuity and Attachment of Equipment Grounding Conductors to Boxes See Page A-10 for more (B)Grounding continuity (D)Nonmetallic boxes IDEAL Grounding Products! 1-800-435-0705 CUSTOMER ASSISTANCE WWW.I DEALI N DUSTRI ES.COM Page 1 of 3 16721 1.6.C.5 Search Technical Data Sheets BR6DyTechnical Data Sheet 'WHEN PERFORMANCE MATTERS MOST" BRADY B-500 POLYMER COATED CLOTH TAPE TDS No. B-500 Effective Date: 19-Aug-2005 Description: Brady B-500 is a polymer coated cloth with a printable topcoat and a rubber based pressure sensitive adhesive. Brady B-500 is a general purpose material for a variety of pre-printed labeling and wire marking applications requiring durability and economy. Brady B-500 has good oil and water resistance and good print durability. B-500 has excellent flexibility for wrapping around curved surfaces. Details: PHYSICAL PROPERTIES TEST METHODS AVERAGE RESULTS Thickness ASTM D 1000 0.0088 inch (0.223 mm) Adhesion to: ASTM D 1000 68 oz/in (74 N/100 mm) -Stainless Steel 20 minute dwell 75 oz/in (82 N/100 mm) 24 hour dwell 63 oz/in (69 N/100 mm) -Polypropylene 20 minute dwell 68 oz/in (74 N/100 mm) 24 hour dwell 20 oz/in (22 N/100 mm) -Textured ABS 20 minute dwell 25 oz/in (27 N/100 mm) 24 hour dwell Tack ASTM D 2979 35 oz(1000 g) PolykenTM Probe Tack 1 second dwell Tensile Strength and Elongation ASTM D 1000 45 lbs/in (788 N/100 mm), 7% -Machine Direction 32 lbs/in (560 N/100 mm), 18% -Cross Direction Application Temperature Lowest application temperature to 50°F(10°C) stainless steel The following testing is performed with pre-printed B-500 white wiremarkers and unprinted flat B-500 samples. Wiremarker samples were wrapped on 0.080"OD wires and flat samples were applied to flat aluminum panels. All samples allowed to dwell 24 hours prior to testing. PERFORMANCE PROPERTIES TEST METHODS TYPICAL RESULTS High Service Temperature 30 days at 175°F(80°C) Slight topcoat darkening at 80°C Low Service Temperature 30 days at-40°F (-40°C) No visible effect Humidity Resistance 30 days at 100°F(37°C), 95% R.H. No visible effect UV Light Resistance 30 days in UV SunlighterTM 100 N o visible effect Weatherability ASTM G 155, Cycle 1 Very slight unwrap to wiremarker, no 30 days in Xenon Arc visible effect to printing Weatherometer Salt Fog Resistance http://www.bradyid.com/bradyid/domino/contentV i ew.do?display=printerFriendly&url=htt... 2/4/2015 Page 2 of 3 ASTM B 117 Slight unwrap to wiremarker, no 30 days in 5%salt fog solution visible effect to printing chamber Abrasion Resistance Taber Abraser, CS-10 grinding Pre-printed wiremarker still legible wheels, 250 g/arm (Fed. Std. 191A, after 100 cycles Method 5306) PERFORMANCE PROPERTY CHEMICAL RESISTANCE Pre-printed B-500 white wiremarkers were wrapped around 0.080"OD wire and unprinted B-500 samples were laminated to flat aluminum panels. Samples allowed to dwell 24 hours prior to test. Testing consisted of 5 cycles of 10 minute immersions in the specified chemicals followed by 30 minute recovery periods. Testing was conducted at room temperature. CHEMICAL REAGENT SUBJECTIVE OBSERVATION OF VISUAL CHANGE APPEARANCE OF WIREMARKER APPEARANCE OF FLAT SAMPLE Methyl Ethyl Ketone Marker fell off Topcoat removed,adhesive failure 1,1,1-Trichloroethane Severe unwrap,topcoat wrinkled Topcoat delamination, adhesive failure • Isopropyl Alcohol Slight unwrap No visible effect • JP-4 Jet Fuel Slight unwrap No visible effect SAE 20 WT Oil No visible effect No visible effect Mil 5606 Oil Slight unwrap No visible effect Speedi Kut Cutting Oil 332 No visible effect No visible effect Gasoline Moderate unwrap Slight adhesive ooze Rust Veto®377 Slight unwrap</td> No visible effect Skydrol®500B-4 Severe unwrap,topcoat wrinkled, Topcoat delaminated from cloth adhesive soft Super Agitene® Moderate unwrap Slight adhesive ooze Deionized Water No visible effect No visible effect 3%Alconox®Detergent No visible effect No visible effect 10%Sodium Hydroxide Solution Severe unwrap Severe edge lift 10%Sulfuric Acid Solution No visible effect No visible effect NorthwoodsTM Buzz Saw Slight unwrap No visible effect Citrus Degreaser 5% Salt Water Solution No visible effect No visible effect Note: Environmental aging and chemical resistance test results may be different on colored B-500 wiremarkers. Product testing, customer feedback, and history of similar products, support a customerperformance expectation of at leasttwo years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80 degrees F(27°C)and 60%RH.We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the risk of using such product.We encourage customers to develop functional testing protocols that will qualify a product's fitness for use, in their actual applications. Trademarks: Alconox®is a registered trademark of Alconox Co. NorthwoodsTM is a trademark of the Superior Chemical Corporation PolykenTM is a trademark of Testing Machines Inc. Rust Veto®is a registered trademark of the E.F. Houghton&Co. Skydrol®is a registered trademark of the Monsanto Company SunlighterTM is a trademark of the Test Lab Apparatus Company Super Agitene®is a registered trademark of Graymills Corporation ASTM:American Society for Testing and Materials(U.S.A.) SAE: Society of Automotive Engineers(U.S.A.) !All S.I. Units (metric)are mathematically derived from the U.S. Conventional !Units.! All S.I. Units(metric)are mathematically derived from the U.S. Conventional http://www.bradyid.com/bradyid/domino/contentV i ew.do?display=printerFriendly&url=htt... 2/4/2015 Page 3 of 3 Units. Note: All values shown are averages and should not be used for specification purposes. Test data and test results contained in this document are for general information only and shall not be relied upon by Brady customers for designs and specifications, or be relied on as meeting specified performance criteria. Customers desiring to develop specifications or performance criteria for specific product applications should contact Brady for further information. Product compliance information is based upon information provided by suppliers of the raw materials used by Brady to manufacture this product or based on results of testing using recognized analytical methods performed by a third party, independent laboratory.As such, Brady makes no independent representations or warranties, express or implied, and assumes no liability in connection with the use of this information. WARRANTY Brady products are sold with the understanding that the buyers will test them in actual use and determine for themselves their adaptability to their intended uses. Brady warrants to the buyers that its products are free from defects in material and workmanship, but limits its obligation under this warranty to replacement of the product shown to Brady's satisfaction to have been defective at the time Brady sold it.This warranty does not extend to any persons obtaining the product from the buyers. This warranty is in lieu of any other warranty, express or implied, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, and of any other obligations or liability on Brady's part. Under no circumstances will Brady be liable for any loss, damage, expense,or consequential damages of any kind arising in connection with the use, or inability to use, Brady's products. Copyright 2015 Brady Worldwide, Inc. I All Rights Reserved Material may not be reproduced or distributed in any form without written permission. Brady North America 16555 W. Good Hope Rd I Milwaukee,WI 53223 I USA I Tel:414-358-6600 I Fax: 800- 292-2289 http://www.bradyid.com/bradyid/domino/contentV i ew.do?display=printerFriendly&url=htt... 2/4/2015 Brady Product Detail Page Page 1 of 1 16721 1 .6.C.5 BoDy WHEN PERFORMANCE MATTERS MOST- 0.250 IN (6.35 MM) DIAMETER-#PSPT-250-1-WT SIZE: 1.015"W x 0.439"H(25.780 mm W x 11.150 mm H) MATERIAL: PermaSleeve®Heat-Shrink Polyolefin QTY/UOM: 100/Roll -411011111%P.. CATALOG#: PSPT-250-1-WT PRODUCT#: 18459 ie f OVERVIEW SPECIFICATIONS Description for 0.250 IN(6.35 MM)DIAMETER PermaSleeve®Heat Shrinkable Wire Marker Sleeves for the TLS 2200®&TLS-PC Link""Thermal Transfer Portable Printers Specification Of 0.250 IN(6.35 MM)DIAMETER Application(s): Panel Identification,Wire&Cable Marking Agency Approval MIL-STD-202,SAE-AS-81531,SAE-DTL-23053/5 Class 1,UL Recognized (s)/Compliance: Size: 1.015"W x 0.439"H(25.780 mm W x 11.150 mm H) Range of Wire Diameter: 0.094"-0.215"(2.39 mm-5.46 mm) Printable Sides: One-Sided Printable Max Characters Per Line For 22 Font#2: Max Lines of Text For Font 3 #2: Shrink Ratio: 3-to-1 Label Type/Style: Sleeve Color: White Wire Gauge: 16 to 10 Finish: Matte Qty Per Row: 1 Material Type: Polyolefin Material Description: PermaSleeve®Heat-Shrink Polyolefin Brady Material#: B-342 Safety Catalog: pg.322 General ID Catalog: pg.61 Recommended Ribbon R4310 Series: Suggested Ribbon Part#: R4310 Printer Compatibility: BMP71,TLS 2200,TLS-PC Link Special Properties: Heat-shrinkable,Self-Extinguishing RoHS Compatibility: Pass 2011/65/EU QTY/UOM: 100/Roll http://www.bradyid.com/bradyid/catalog/productDetailView.do?forward=PrinterFriendly&... 2/4/2015 Brady Product Detail Page Page 1 of 1 16721 1.6.C.5 BoDy WHEN PERFORMANCE MATTERS MOST- 0.500 IN (12.70 MM) DIAMETER-# PSPT-500-175- WT SIZE: 1.765"W x 0.851"H(44.830 mm W x 21.620 mm H) MATERIAL: Perma5leeve®Heat-Shrink Polyolefin QTY/UOM: 100/Roll CATALOG#: PSPT-500-175-WT PRODUCT#: 18468 • . OVERVIEW SPECIFICATIONS Description for 0.500 IN(12.70 MM)DIAMETER Perma5leeve®Heat Shrinkable Wire Marker Sleeves for the TLS 2200®&TLS-PC Link""Thermal Transfer Portable Printers Specification Of 0.500 IN(12.70 MM)DIAMETER Application(s): Panel Identification,Wire&Cable Marking Agency Approval MIL-STD-202,SAE-AS-81531,SAE-DTL-23053/5 Class 1,UL Recognized (s)/Compliance: Size: 1.765"W x 0.851"H(44.830 mm W x 21.620 mm H) Range of Wire Diameter: 0.187"-0.450"(4.75 mm-11.43 mm) Printable Sides: One-Sided Printable Max Characters Per Line For 41 Font#2: Max Lines of Text For Font 7 #2: Shrink Ratio: 3-to-1 Label Type/Style: Sleeve Color: White Wire Gauge: 8 to 1 Finish: Matte Qty Per Row: 1 Material Type: Polyolefin Material Description: PermaSleeve®Heat-Shrink Polyolefin Brady Material#: B-342 Safety Catalog: pg.322 General ID Catalog: pg.61 Recommended Ribbon R4310 Series: Suggested Ribbon Part#: R4310 Printer Compatibility: BMP71,TLS 2200,TLS-PC Link Special Properties: Heat-shrinkable,Self-Extinguishing RoHS Compatibility: Pass 2011/65/EU QTY/UOM: 100/Roll http://www.bradyid.com/bradyid/catalog/productDetailView.do?forward=PrinterFriendly&... 2/4/2015