Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A15-0012_Control Display Modules_1446057660.pdf
EST Catalog► EST3 Life Safety Platform SES T TM 16721 1 .6.C.6 )1111/Life Safety & Communications ` . ° • ° .l :0 • °t0 71 Control Displaylac EH re Modules (P°> 3-LDSM, 3-24x series, 3-1 2)o< series, ® �E 3-6/351 xxx series r°1111 � �.� - Overview Standard Features The EST3 Control Display modules provide the emergency user • Programmable LED flash rates with the simplest of interfaces, lights and switch control.The Con- • Membrane style tactile pushbuttons trol Display modules install over local rail modules.The local rail modules supply the power and drivers via a ribbon cable connec- • Software supported for toggle,and latching interlock switch action tion to the control display modules.The displays mount over any • Slide in labels local rail module maximizing the flexibility of design layout.When a display module is required where no local rail module exists, • Lamp test an LED Display Support Module 3-LDSM mounts to the local rail providing support for one Control Display Module. Surface mount technology used to minimize space, also reduces the power requirements of display modules. Slide-in labels keep the control display modules flexible and allow labeling for local languages. Module lamp test can be programmed to any spare control switch or a local node lamp test is initiated by simultaneously operating the Alarm Silence and Trouble Silence switches on the 3-CPU. Page 1 of 4 DATA SHEET 85010-0055 Not to be used for installation purposes. Issue 6 Application Notes or"Off." Programming of the switches to multiple relays keeps operational design choices open.The user returns the system Control Display Modules come in a variety of types providing op- control of the remote device to the Life Safety system by simply erational flexibility.There are five types of display modules available pressing Auto.The Auto LED programs to its related switch and with EST3. gives positive feed back to the user by turning on yellow when the Typically alarm zone annunciation appears on any of the first four system has active control of remote devices. module types shown.The first module supports simple zone Individual switch LEDs are also programmable.As an example the annunciation;the second,zone annunciation with zone disable; "Open"or"On" LED(green)could program to follow its related the third,alarm and trouble zone annunciation,the fourth alarm switch or, program to follow a remote monitor input and provide and trouble zone annunciation with zone disable. From a simple positive feedback of the remote devices control status. If budget one LED annunciation point to higher functionality, EST3 fills the restrictions prevent"sail type"positive feedback, EST's unique requirements. command processing satisfy requirements for positive feedback of Simple Control Examples The fifth module is very adaptable HVAC control systems.Any switch command will send a signal to / \ to system requirements for audio the 3-CPU for processing.While in this state the LED associated ❑ ON F or remote equipment control. with the switch will flash. Once the command has been received a Each module contains 18 LEDs by a remote Signature Series Module,the module(since it is n and 18 switches. Each group of intelligent with its own microprocessor)will issue a"Processed" ❑ AUTO three switches has a latching- command back to the 3-CPU which will latch the LED associ- # interlock to support operations ated with the switch "ON"steady.This same process is used for ❑ OFF 5 that must be kept separated.The all audio speaker selections ensuring the circuit is connected.A ) interlock is under software control variety of switch and associated LED colors are available to meet • the demands of the specifiers application. only one switch is active at a p given time. EST3 software makes Life Safety Systems are generally passive requiring only occasional ❑ OPEN meeting the wide variety of ap operation.Yet, in an emergency the user must be able to identify plications needed with today's system operation and status quickly and easily. LCD displays are codes and building system opera - Damper excellent for identifying specific information, but even a large LCD ❑ AUTO tions easy. 5th Fir can not display overall "system"status as effectively as LEDs and Switches.The EST3 Control Display modules are designed to pro- vide❑ CLOSE simple identification and operation of system functions for the For fan control the emergency emergency user.They provide positive feedback of control activity user assumes control of the with unrivaled selection of display configurations and mounting remote device by selecting "On" location options. Installation and Mounting Engineering Specification Display The Life Safety system shall incorporate annunciation of Alarm, - Supervisory,Trouble and Monitor operations. Annunciation must be through the use of LED display strips complete with a means to °44' custom label each LED as to its function.Where applicable control of remote smoke control devices must be made available at the L control center. Switches with LEDs must provide positive feed fLz:'''' w," back to the operator of remote equipment status.Where voice au- , dio is required a means of paging individual zones must be made. ® ° The status of each paging zone must be annunciated. It must be R POI 1rill ❑I ) .10 oo possible to selectively page into specific zones. It shall be possible Label to manipulate the evacuation of the building from the main control Local Rail/ POI I SOI 1 to center. It must be possible for the emergency operator to put POI 1 SOI 1 °o specific zones into evacuation manually. Module POI I COI 1 °o POI I rill I °o POI I tOI I ..°..0 POI SOI I Oo POI I SOI I 0 POI I r❑I 1 00 POI I tOI I °❑ POI C❑I I 00 Page 2 of 4 DATA SHEE N 85010-0055 Not to be used for installation purposes. Issue 6 Technical Specifications Catalog Number of Alarm LED Colors Switches Applications Number LEDs Current 3-LDSM N/A N/A N/A Provides interface for one Control Display Module 5 mA ,❑ Alarm Main Electrical ❑ Electrical Room ❑ Trouble Room 3-24R red Alarm Annunciation 3-24Y yellow Supervisory and Trouble Annunciation 2 mA base 3-24G 24 green 0 Monitor Annunciation +1.5 mA per 12 red over 12 Red LEDs Alarm Annunciation Yellow LEDs Supervisory active LED 3-12RY yellow pairs Annunciation /❑ \ /❑ EVAC \ /❑ SHELTER \ 5th Floor Message Message • / ♦ i 3-12SR red Alarm Annunciation with enable/disable operation 2 mA base 3-12SY 12 yellow 12 Supervisory Annunciation with enable/disable operation +1.5 mA per 3-12SG green Monitor Annunciation,Page select active LED /❑ \ /❑ EVAC \ /❑ AMBER ` 5th Floor ❑ ❑ Strobe ❑ Strobe • / ♦ / / 3-12/S1 GY 12 groups green/yellow Zone Page select with Trouble Annunciation 2 mA base 3-12/S1 RY of two w/ red/yellow 12 Alarm and Trouble Annunciation with enable/disable +1.5 mA per 3-12/S2Y switch yellow/yellow Supervisory and Trouble Annunciation with enable/disable active LED ' IIIf J ON ` / ❑f J OPEN D Trouble Trouble A 0^ AUTO RI J AUTO M Normal Normal P ❑[ JOFF o1 JCLOSE RE • / • / Green/Yellow 1 2 3 On-Auto-Off fan and Open-Auto-Close Damper Control with 2mA base 3-4/3SGYWR 4 LEDs and White/Red switches Trouble and Normal LED indicators +1.5mA per active LED ❑• ALERT 5th ❑ ON A ❑ OPEN D F H A ❑ PAGE L ❑ AUTO u ❑ AUTO M 0 P 1=1 EVAC R ❑ OFF #4 ❑CLOSE R N / \ / N / green/yellow/ 3-6/351 G2Y Six On-Auto-Off fan and Open-Auto-Close Damper Control 2 mA base 6 groups of yellow groups of +1.5 mA per 3-6/351 GYR 3 w/switch green eydellow/ three Page and Evacuation select with zone trouble active LED Notes: 1) All Control Display Modules are UL and ULC listed. 2) All Control Display Modules mount over one Local Rail Module. If no local rail module exists the 3-LDSM mounts to local rail and supports one control display module. Page 3 of 4 DATA SHEET 85010-0055 Not to be used for installation purposes. Issue 6 Ordering Information TO WA R D S Catalog Shipping Number Description Weight A UTC Fire&Security Company 0.451b 3-LDSM LED Display Support Module Detection&alarm since 1872 (.2kg) 3-24R 24 Red LED Display Module u.S. 3-24Y 24 Yellow LED Display Module T 888-378-2329 3-24G 24 Green LED Display Module F 866-503-3996 3-12SR 12 switches with 12 Red LED Display/Control Module Canada 3-12SY 12 switches with 12 Yellow LED Display/Control Module Chubb Edwards 3-12SG 12 switches with 12 Green LED Display/Control Module T 519 376 2430 3-12RY 12 Red LED and 12 Yellow LED Display Module F 519 376 7258 12 switches with one Green and one Yellow LED per switch Display/ 3-12/Si GY Control Asia Module T:+65 6391 9300 12 switches with one Red and one Yellow LED per switch Display/ 0.351b F:+65 6391 9306 3-12/S1 RY Control Module (.12kg) India 3 12/S2Y 12 switches with two Yellow LEDs per switch Display/Control T:+91 80 4344 2000 Module F:+91 80 4344 2050 3 6/3S1 G2Y Six groups of three switches.Each switch with one LED.LEDs provided Green,Yellow,Yellow. Australia 12 switches in four groups of three switches,switch one with a green T+61 3 92391200 3-4/3SGYWR LED,switch two with yellow and white LEDs and switch three with a F+61 3 9239 1299 red LED Europe 3-6/3S1 GYR Six groups of three switches.Each switch with one LED.LEDs T+32 2 725 11 20 provided Green,Yellow,Red F+32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 utcfi reandsecu rity.com ©2010 UTC Fire&Security. All rights reserved. C Page4of4 DATA SHEE 85010-0055 Not to be used for installation purposes. Issue 6