A15-0012_Control Relay Modules_1446057600.pdf
EST Catalog►Intelligent Input/Output BEST TM 16721 1.6.C.3 )1111/-Life Safety & Communications Control Relay ..........._1141116. Modules 111. . SIGA-CR, SIGA-MCR, SIGA- -IMpal. CRR, SIGH-MCRR • z ' 1 mIir � = r� f J l I. • • Ig( gMEA q 4. O t 1 SIGA-CR U SIGA-MCR Overview Standard Features The Control Relay Module and the Polarity Reversal Relay Module • Provides one no/nc contact(SIGA-CR/MCR) are part of the Signature Series system.They are intelligent analog Form "C"dry relay contact can be used to control external ap- addressable devices available in either plug-in(UIO)versions, or pliances such as door closers,fans, dampers etc. standard 1-gang mount versions. • Allows group operation of sounder bases The SIGA-CR/MCR Control Relay Module provides a Form"C" The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc out- dry relay contact to control external appliances such as door clos- put,thus activating all Sounder Bases on the data loop. ers,fans, dampers etc.This device does not provide supervision • Plug-in(UIO)or standard 1-gang mount of the state of the relay contact. Instead,the on-board micro- UIO versions allow quick installation where multiple modules processor ensures that the relay is in the proper ON/OFF state. are required.The 1-gang mount version is ideal for remote Upon command from the loop controller,the SIGA-CR/MCR relay locations that require a single module. activates the normally open or normally-closed contact. • Automatic device mapping The SIGA-CRR/MCRR Polarity Reversal Relay Module provides Signature modules transmit information to the loop controller a Form"C"dry relay contact to power and activate a series of regarding their circuit locations with respect to other Signature SIGA-AB4G Audible Sounder Bases. Upon command from the devices on the wire loop. Signature loop controller,the SIGA-CRR reverses the polarity of its • Electronic addressing 24 Vdc output,thus activating all Sounder Bases on the data loop. Programmable addresses are downloaded from the loop con- Standard-mount versions(SIGA-CR and SIGA-CRR)are troller, a PC,or the SIGA-PRO Signature Program/Service Tool; installed to standard North American 1-gang electrical boxes, there are no switches or dials to set. making them ideal for locations where only one module is re- • Intelligent device with microprocessor quired. Separate I/O and data loop connections are made to each All decisions are made at the module to allow lower com- module. munication speed with substantially improved control panel Plug-in UIO versions(SIGA-MCR and SIGA-MCRR)are part response time and less sensitivity to line noise and loop wiring of the UIO family of plug-in Signature Series modules.They func properties;twisted or shielded wire is not required. tion identically to the standard mount versions, but take advantage • Ground fault detection by address of the modular flexibility and easy installation that characterizes Detects ground faults right down to the device level. all UIO modules.Two-and six-module UIO motherboards are available.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Edwards enclosures. Pagel of 6 DATA SHEET 85001-0239 Not to be used for installation purposes. Issue 7.2 Installation Application SIGA-CR and SIGA-CRR:modules mount to North American The operation of Signature Series control relays is determined by 21/2 inch(64 mm)deep 1-gang boxes and 11/2 inch(38 mm)deep their sub-type code or"Personality Code." 4 inch square boxes with 1-gang covers and SIGA-MP mounting Personality Code 8:CONTROL RELAY(SIGH-CR/MCR)-Dry plates.The terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Contact Output.This setting configures the module to provide one Form"C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 Compatible electrical box amp @ 120 Vac(or 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configuration is re 161,1111610, --------- -poire- quired. , Personality Code 8: POLARITY REVERSAL RELAY MODULE + (SIGA-CRR/MCRR).This setting configures the module to re- 1 I Wall plate,white verse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ ♦�i,l� 24 Vdc(pilot duty). PersonalityCode 8 is assigned at the ��,i< (1-gang) 9 factory. "'�' No user configuration is required. 00, a Compatibility ,, The Signature Series modules are compatible only with EST's Status LEDs Signature Loop Controller. 9, LED viewing ports . C Warnings & Cautions 9 w This module will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further SIGA-MCR and SIGA-MCRR:mount the UIO motherboard safeguards with your local fire protection specialist. inside a suitable Edwards enclosure with screws and wash- ers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the Testing & Maintenance captive screws.Wiring connections are made to the terminals on the motherboard(see wiring diagram). UIO motherboard terminals The module's automatic self-diagnosis identifies when it is defec- are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. tive and causes a trouble message.The user-friendly maintenance program shows the current state of each module and other per- _u10 Motherboard tinent messages. Single modules may be turned off(deactivated) 1 6-32 temporarily,from the control panel.Availability of maintenance Self-tapping features is dependent on the fire alarm system used. Scheduled screws maintenance(Regular or Selected)for proper system operation 0- *I ` should be planned to meet the requirements of the Authority Hav- Plug-in 0,Captive ing Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ Module ULC 536 standards. -- -- fl--„t I #6 Flat washers J 4—Cabinet or electrical enclosure Electronic Addressing -The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Edwards recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2 of 6 DATA SHE E , 85001-0239 Not to be used for installation purposes. Issue 7.2 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16(1.0mm2), #14 AWG(1.50mm2)and#12 AWG(2.5mm2)wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed A TB2 0 8 7 6 • • • Red LED Green LED (Alarm/Active) '3O2 lO 411-- (Normal) TBl 0 0 0 0 Notes IA Refer to Signature Loop Controller Installation Sheet for wiring specifications. DATA IN(+) DATA OUT(+) J} A NFPA 72 requires that the SIGA-CR/SIGA-MCR be DATA IN(-) DATA OUT(-) installed in the same room as the device it is control- From Signature Controller To Next Device ling.This requirement may not apply in all markets. or Previous Device Check with your local AHJ for details. 0 A The SIGA-UIO6R and the SIGA-U102R do not come with TB14. SIGA-CR Control Relay The SIGA-U106 does not come with TB8 through TB13. Normally Open Common Normally Closed A\Supervised and power-limited. /\ If the source is nonpower-limited,maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR,or an equivalent in accordance with the National Electrical Code. L-111P/1\ 7) Maximum#12 AWG(2.5mm2)wire. Q1 2 3 4 Min.#18(0.75mm2). A Data In+ , 4 NUS® 3 ®4 Q IP �z 1 ,� TB14 + No connections required for Data Out 4 MCR.Other modules may require connections. a 4 Green LED(Normal) ® rA 2 Red LED(Active) PG:®a a TB15 1234 A'T\ No connections required for MCR.Other modules may require connections. SIGA-MCR Control Relay Page 3 of 6 DATA SHEET 85001-0239 Not to be used for installation purposes. Issue 7.2 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16(1.0mm2), #14 AWG(1.50mm2)and#12 AWG(2.50mm2)wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. AB4G AB4G AB4G Audible Base Audible Base Audible Base o o o ® 1 ® 0. e ® o o ® =IL 6254A-003 I EOL Relay Listed 24 VDC + —A II Nominal Power II 111 n n ?I a 1 Ii) II 11 a II Irl fl 11 II oI, A Supply _ — — A Mi A A A ® A D h VA ii • 1_11 0 © 1 • • • • • • • • • CR CRR ASIGA—CRR CT1 0 0 0 0 0 0 _ Ir II I A � L Signature Controller A A Optional CR for disabling/disconnecting sounder base SIGA—MCRR SIGA-CRR Schematic SIGA-MCRR Schematic /® o o ®\ Power In Power Out Polarity Reverses Power In Power Out _ <a When Activated Polarity reverses r— O 6254A-003 + `T ��when activated. Z Z Ell �; EOL Relay [II 111 111 11 J Audible O I I8 �. kri0 � Z. _ + 1{ o., required for • Bases supevision + Q Q Q ill P•: I'D IDa a a to u o 0 0 Ell I I m'h II I I II 'Ni NM ell_ 4 3 2 1 .� �.� `� II 111® I. El J •a�J Signature A . 8 7 Notes Data Data Out —" ' • • • Circuit A + Refer to the Signature controller installation sheet for 44111111E�For normal operation CT1 wiring. Q *r+ r For Ge neral Fire Alarm Operation 0 0 /L\ One Pair of Wires(24 Vdc power). UL/ULC Listed + 4 3 2 1 24 Vdc power — 0 One Pair of Wires(Signature Data). supply or I CT Zf 12117 / Single Wire(24 Vdc power). —' 1 2 /o\ 3 4 ` // 4�\ % 1 2 3 4 The SIGA-UIO6R and the SIGA-UIO2R do not come ■•• MCRR /�� with TB14. A A pppp ipeip 510(R)series motherboard /b\The SIGA U106 does not come with TB8 through Data oat+ `wIr /� TB13./ \ � • i Q No connections required for Sienatu . 14 S MCRR.Other modules may A Supervised and power-limited. Data M� ' 11\ require connections. Circuit 1 U1 , \ 8 If the source is nonpower-limited,maintain a space 1B7 of 1/4 inch from power-limited wiring or use FPL, + Data In FPLP,FPLR,or an equivalent in accordance with the — Green LED(Normal) National Electrical Code. 1 z Red LED(Active) 9 Maximum#12 AWG(2.5 mm2)wire;Minimum #18 WM WM .. 1 No connections required for TB15 MCRR.Other modules maAWG(0.75 mm2). Green LED(Normal) rl l�r�Ir�I�r�I� Y 10 End-of-Line Relay must monitor and report power Red LED(Active) lw;:2 require connections. supply trouble to control panel. .L A 11 Class B Data wiring may be"T-tapped." Optional MCRR or MCR for No connections required for MCRR.Other disabling/disconnecting an audible base. modules may require connections. Page 4 of 6 DATA SHE E r 85001-0239 Not to be used for installation purposes. Issue 7.2 Specifications Catalog Number SIGA-CR SIGA-MCR SIGA-CRR SIGA-MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8(Factory Set) Personality Code 8(Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby=10OpA Activated=100pA Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Relay Type and Rating Form"C"24 VDC=2 amps(pilot duty)120 Vac=0.5 amps 220 Vac(non-UL)=0.5 amps Mounting North American 21/2 inch Plugs into UIO2R,UIO6R or North American 21/2 inch Plugs into UIO2R,UIO6R or (64 mm)deep 1-gang boxes UIO6 Motherboards (64 mm)deep 1-gang boxes UIO6 Motherboards and 11/2 inch(38 mm)deep and 11/2 inch(38 mm)deep 4 inch square boxes with 4 inch square boxes with 1-gang covers and SIGA- 1-gang covers and SIGA- MP mounting plates MP mounting plates Construction&Finish High Impact Engineering Polymer Storage and Operating Operating Temperature:32°F to 120°F(0°C to 49°C) Environment Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashes when in alarm/active Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,CSFM, MEA Ordering Information Catalog Number Description Ship Weight-lbs (kg) SIGA-CR Control Relay Module(Standard Mount) 0.4(0.15) SIGA-MCR Control Relay Module(UIO Mount) 0.18(0.08) SIGA-CRR Polarity Reversal Relay Module(Standard Mount) 0.4(0.15) SIGA-MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box-Red, 1-gang 1 (0.6) 27193-16 Surface Mount Box-White, 1-gang 1 (0.6) SIGA-UIO2R Universal Input-Output Module Board w/Riser Inputs-Two Module Positions 0.32(0.15) SIGA-UIO6R Universal Input-Output Module Board w/Riser Inputs-Six Module Positions 0.62(0.28) SIGA-U106 Universal Input-Output Module Board-Six Module Positions 0.56(0.25) SIGA-AB4G Audible(Sounder)Detector Base 0.3(0.15) Accessories MFC-A Multifunction Fire Cabinet-Red,supports Signature Module Mounting Plates 7.0(3.1) SIGA-MB4 Transponder Mounting Bracket(allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) Page 5 of 6 DATA SHEET 85001-0239 Not to be used for installation purposes. Issue 7.2 Signature Series Overview The Signature Series intelligent analog-addressable system from Edwards is an entire TOWARDS family of multi-sensor detectors and mounting bases, multiple-function input and output A UTC Fire&Security Company modules, network and non-network control panels, and user-friendly maintenance and Detection&alarm since 1872 service tools.Analog information from equipment connected to Signature devices is gathered and converted into digital signals.An onboard microprocessor in each Signature u.s. device measures and analyzes the signal and decides whether or not to input an alarm. T 888-378-2329 The microprocessor in each Signature device provides four additional benefits-Self-di- F 866-503-3996 agnostics and History Log,Automatic Device Mapping, Stand-alone Operation and Fast, Canada Stable Communication. Chubb Edwards T 519 376 2430 Self-diagnostics and History Log-Each Signature Series device constantly runs self- F 519 376 7258 checks to provide important maintenance information.The results of the self-check are Southeast Asia automatically updated and permanently stored in its non-volatile memory.This information T:+65 6391 9300 is accessible for review any time at the control panel, PC,or using the SIGA-PRO Signa- F:+65 6391 9306 ture Program/Service Tool.The information stored in device memory includes: India • Device serial number, address, and type T:+91 80 4344 2000 •Time and date of last alarm F:+91 80 4344 2050 • Most recent trouble code logged by the detector— 32 possible trouble codes may be Australia used to diagnose faults. T+61 3 9239 1200 F+61 3 9239 1299 Automatic Device Mapping-The Signature Data Controller(SDC)learns where each Europe device's serial number address is installed relative to other devices on the circuit.The T+32 2 725 11 20 SDC keeps a map of all Signature Series devices connected to it.The Signature Series F+32 2 721 86 13 Data Entry Program also uses the mapping feature.With interactive menus and graphic Latin America support,the wired circuits between each device can be examined. Layout or"as-built" T 305 593 4301 drawing information showing branch wiring(T-taps), device types and their address are F 305 593 4300 stored on disk for printing hard copy.This takes the mystery out of the installation.The preparation of as-built drawings is fast and efficient. utcfi reandsecu rity.com Device mapping allows the Signature Data Controller to discover: ©2010 UTC Fire&Security. All rights reserved. • Unexpected additional device addresses • Missing device addresses •Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation-A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone(degrade)mode. If Sig- nature loop controller CPU communications fail for more than four seconds, all devices on that circuit go into standalone mode.The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices.When connected to a panel utilizing standalone operation, modules with their"personality"set as alarm devices(IDC)will alarm should their slave alarm-initiat- ing device activate. a C Page 6 of 6 DATA SHEE , 85001-0239 Not to be used for installation purposes. Issue 7.2