HomeMy WebLinkAboutA15-0012_EST3 Cabinet Chassis_1446057660.pdf EST Catalog► EST3 Life Safety Platform ESTrM )1111/-Life Safety & Communications 16721 1.6.0.1 11111111 lllllllllllll 11111111 11111 11111111 111111 EST3 Cabinets and - o Chassis �E 3-CAB series, 3-RCC Series 3-RCC series, ®t�"I'III I I I I EN54-2:1997+A1 and EN54-4:1997+A1:2002+A2 pending 3-CHAS7 series, BC-1 I 3-CAB Series Overview Standard Features EST3 has a wide selection of cabinet arrangements allowing the • Right or left hand hinging of doors greatest use of EST3's flexible modular design. Lobby enclosure • Lag and Keyway holes for quick mounting wallboxes are manufactured from#14 AWG cold rolled steel with a gray baked enamel finish. Lobby enclosure doors are manu- • Attack rated door for security applications factured from#14 AWG cold rolled steel and have a modern • Knockouts for 3/4 inch conduit contoured door design with integral viewing window.The excep- tion is the small lobby enclosure 3-CAB5.The 3-CAB5 wallbox • Attractive contour door design on lobby enclosures and non-contoured door are#16 AWG cold rolled steel. Lobby • Combination flush or surface mounting lobby enclosure design enclosure doors come with gray baked enamel or optional red baked enamel finishes.The EST3 lobby enclosures back boxes, • Remote closet cabinets for electrical closet mounting support doors and chassis units are ordered and shipped separately.The up to 65 AMP hour batteries 3-CAB5 lobby enclosure comes complete with door and back box • Optional earthquake hardening: OSHPD seismic pre-approval providing space to mount five local rail modules. for component Importance Factor 1.5 The EST3 remote closet cabinet design allows the installation of control panel electronics in electrical closets.The remote closet cabinets have left hand hinged doors and are available with red finish only. Optional display modules used for system diagnostics display, mount behind the closet cabinet door and are not visible with the door closed. Page 1 of 4 DATA SHEET 85010-0067 Not to be used for installation purposes. Issue 10 Application Lobby Enclosures 24.,21n(60.9 cm) 3-CAB7B 3.0 in 22.751n(57.8 cm) Lobby Enclosures 3-CAB14B (7.7 cm) 2zsm(a53cm) 34 cm) 3-CAB21B 25 in °oRl EST3 lobby enclosures provide space for control, monitoring and (3'8cm) cl_ u u P 3.861n y.°0 9.66 cm, ALF°71 ° display modules where they remain visible even with the door j <e9I m, closed and secure. Ideal for mounting in lobby's where appear- 27.34 in(89.4 cm) ance is important, maximum mounting flexibility is provided with 3.661" 4.37 in 9.80 cm) (11.1 cm) doors that will mount for right or left hand opening. Lobby enclo- ^ sures come in several sizes to match individual project require- 6 • 6• T ments . C € E The 3-CAB5 series semi-flush or surface mounts.A built in rail Chassis assembly provides space for up to five local rail modules, no - . chassis assembly needed. Back space for 1-1/2 footprints gives room for a power supply and a 1/2 footprint module and 10 AHg batteries.The local rail module spaces provide room for amplifiers, Chassis E common control and annunciation modules. m S j o • The 3-CAB7 semi-flush or surface mounts and has a contoured g o a E c front door with viewing window. Space is provided for two 17 X °, AH batteries and one chassis assembly providing seven local rail chassis module spaces. 1 c • The 3-CAB14 semi-flush or surface mounting and has a con- 1.251n toured front door with viewing window. Space is provided for two (3.16 an) BATTERY AREA 17AH batteries and two chassis assemblies each providing seven DO NOT INSTALL CONDUIT . local rail module spaces. b The 3-CAB21 semi-flush or surface mounts and has a contoured front door with viewing window. Space is provided for two 17AH batteries and three chassis assemblies each providing seven local rail module spaces. 25.0 In(63.5 cm) Surface Mounted N 23.25 in(59.03 cm) 3.55 in Remote Closet Cabinets 21.44 in(54.46 cm) Remote Closet Cabinets 1.75 in) 1.25 in(3.18 cm) 3-RCC7R (4.45 cm) ,M, 3-RCC14R Remote closet cabinets provide an economical way of installing 3-RCC21R bin equipment in locations where esthetics are not paramount, like ALL KNOCKOUTS I (15.2 cm) 3/4• FOR CONDUIT electrical closets.You can have optional display modules used for , (IS em) system diagnostics display mounted behind the front door.These < , 21 in(53.3 cm) _> 5.641n 114.4 cm) OUTER DOOR F(5.1 cm) (14.3 cm) r display modules will not be visible with the door closed. Remote A A „ Y closet cabinets are surface mounting and come in sizes providing 1 ^ 8 a space for one to three chassis with room for standby batteries.A E 8 . UL Listed attack rated door having a 2-minute rating is available for aChassis the 3-RCC7R cabinet.This door is required for security applications. Installation and Mounting U o¢i LobbyEnclosure 14.0 in(35.56 cm) 12.7 in(32.26 cm) Chassis 3-cab5B 3.1 in 10.9 in(27.69 cm) 4, 8 (7.87 cm) 1.5 in 1.3 in (3.81 cm) i m (3.30 cm) *= 3.86 in m Ri ALL KNOCKOUTS � Y Y (9.80 cm) _ FOR 3/4.CONDUIT (1.9 cm) TOP VIEW I ' 1.65 in n OUTER DOOR lF (4.19 cm) Chassis* 3.86 in 16.4 in(41.66 cm) " 5 U 2.6 in 9.80 cm) 2 nn (6.6 cm) pp m A A 0 1.3 in BATTERY AREA (3.3 cm) £ c1 • 1 • DO NOT INSTALL CONDUIT a N BACKBOX C v NRcc.cORl • 625 in 1-; (1.6 cm) mcc 0 . Oc 0 N `� a cc e LU c *The lower mounting space can be used for an MN-BRKT1 i. 1.3 in • , N(3.3 cm) N o bracket,which holds MNEC interface equipment including an MN- " NETSW1 Ethernet network switch, an MN-ABPM Audio bridge, p BATTERY AREA an MN-FVPN VoIP module, and an MN-COM1S Communications 8 7 DO NOT INSTALL CONDUIT module. v v Page 2 of 4 DATA Si.,, , 85010-0067 Not to be used for installation purposes. Issue 10 BC-1 Dimensions o o I OTop view O 7.251in(18.42 cm) o e Note:Knockouts support } 0.75 in(1.91 cm)conduit e18.25 in(46.34 cm) w 1t i m 8' 16.00 in(40.65 cm) 8 O Fuse- OQ IMSNS+Terminal © 0 block ® Front view 14.00 in Side view (35.56 cm) • 24 or 40 Ah 24 or 40 Ah Battery Battery O •o L L 0 I Ordering Information Catalog Description Equipment Battery Space Ship Wt. Number Mounting Space lb.(Kg) Lobby Enclosures -Outer doors with viewing window Five local rail modules 3-CAB5 Cabinet w/Wallbox,door and chassis One footprint and Two-12V10A 30(13.6) 1/2 footprint module 3-CAB7B Wallbox only One Chassis Four-6V8A Two-12V10A Two- 30(13.6) 3-CAB7B-E Wallbox only,EN54"certified CE 1 Chassis 12V17A 30(13.6) 3-CAB7D(R) Inner and outer doors for 3-CAB7B N/A 10(4.5) 3-CAB7D(R)-E Inner&outer doors for 3-CAB7B,EN54",CE 10(4.5) 3-CAB14B Wallbox only Two Chassis Four-6V8A Two-12V10A Two- 42(19.1) 3-CAB14B-E Wallbox only,EN54"certified CE 2 Chassis 12V17A 42(19.1) 3-CAB14D(R) Inner and outer doors for 3-CAB14BN/A 15(6.8) 3-CAB14D(R)-E Inner&outer doors for 3-CAB14B,EN54",CE 15(6.8) 3-CAB21 B Wallbox only Three Chassis Four-6V8A Two-12V10A Two- 55(25) 3-CAB21 B-E Wallbox only,EN54"certified CE 3 Chassis 12V17A 55(25) I 3-CAB21 D(R) Inner and outer doors for 3-CAB21 B N/A 20(9.1) 3-CAB21 D(R)-E Inner&outer doors for 3-CAB21 B,EN54",CE 20(9.1) Remote Closet Enclosure- No viewing window 3-RCC7R Red wallbox and door One Chassis Four-6V8A,Two-12V10A 37.5(17) 3-RCC7R-E Red wallbox and door,EN54"certified CE Two-12V17A,Two-12V50A 37.5(17) ATCK Attack rated door for 3-RCC7R N/A 26(11.8) 3-RCC14R Red wallbox and door 53(24) Two Chassis Four 6V8A 3-RCC14R-E Red wallbox and door,EN54"certified CE 53(24) Two-12V10A,Two-12V17A 3 RCC21 R Red wallbox and door Three Chassis Two-12V50A,Two-12V652 70(31.8) 3-RCC21 R-E Red wallbox and door,EN54"certified CE 70(31.8) Chassis Assemblies 3-CHAS7 Takes one chassis space in wallbox,provides space for 7 local rail modules, up to two power supplies,and a 1/2 footprint 8.4(3 8)J module. 3-ASU"" Takes one chassis space in wallbox,provides an audio source unit/w microphone and an inner door filler plate. 15(6.8) 3-ASU/4"" Takes one chassis space in wallbox,provides an audio source unit /w microphone and four local rail module spaces. 15(6.8) 3-ASU/FT"" Takes one chassis space in wallbox,provides an audio source unit /w microphone and Firefighters Telephone 20(9.1) 3-FTCU"" Takes one chassis space in wallbox,provides Firefighters Telephone Control unit and inner door filler plate. 15(6.8) MN-BRKT1 Takes one chassis space in wallbox,provides mounting for MNEC interface equipment 4.0(1.8) FSB-BRKT Mounting bracket for FSB-PC communications bridge.Allows FSB-PC to mount on the side of a Chass7 1.0(0.45) more... Notes: 1. All lobby enclosures,wallboxes and doors have a textured gray enamel finish; UL 365 category APAW,UL 1610 category AMCX,UL 1635 category AMCX outer doors are available in red by adding the suffix"R"to the catalog number,i.e. ULC-S527,ULC-S301,ULC-S302,ULC-S303,ULC-S306,ULC/ORD-C1076, 3-CAB7DR. ULC/ORD-C693 2. Remote closet cabinets will support 65 AH batteries with the use of the 3-BATS Please refer to EST3 Installation and Service Manual for complete system require- Battery Shelf,which reduces the enclosure's chassis capacity by one chassis. ments. 3. The EST3 is modularly listed under the following standards: *EN54-2:1997+A 1 and EN54-4:1997+A1:2002+A2 pending UL 864 categories:UOJZ,UOXX,UUKL and SYZV,UL 2572,UL 294 category ALVY,UL 609 category AOTX,UL 636 category ANET,UL 1076 category APOU, ""Add"-CC"for City of Chicago. Page 3 of 4 DATA SHEET 85010-0067 Not to be used for installation purposes. Issue 10 Accessories Battery Shelf for RCC Enclosures.Takes one chassis space. Room for TO WA R D S 3-BATS up to one 65 AH or two 50 AH batteries. 3(1.36) A UTC Fire&Security Company BC-1 Battery Cabinet-supports up to two 40 amp hour batteries. 3-BTSEN Battery sensor/distribution module _ 0.5(.2) Detection&alarm since 1872 BC-1 EQ BC-1 -Seismic Battery hold down for BC-1. Supports up to two 40 Ahr batteries. Order BC-1 Separately. u.S. 3-CAB-Seismic Battery hold-down for 3-CAB 7, 14 or 21. Supports two 1 2V T 888-378-2329 3-CABEQ batteries from 10 Ah up to 18 Ah.Comes with EST3 Chassis hardening hardware F 866-503-3996 and instructions. Order 3-CAB7,3-CAB14 or 3-CAB21 separately.See note 1. Canada 3-RCC series-Seismic Battery hold-down.Supports one set of two 50 Ah Chubb Edwards 3-RCCEQ50 batteries.Comes with EST3 Chassis hardening hardware and instructions.Order T 519 376 2430 3-RCCxxR separately.See note 1. F 519 376 7258 3-RCC series cabinet-Seismic Battery hold-down. Supports one set of two 65 Southeast Asia 3-RCCEQ65 Ah batteries(one battery in bottom of cabinet,one battery mounted on 3-BATS). T:+65 6391 9300 Order 3-RCCxxR cabinet and 3-BATS separately.See note 1. F:+65 6391 9306 3-TAMP Tamper switch for 3-CAB7,3-CAB14 and 3-CAB21 cabinets. Mounts 0.5(.2) to side of cabinet. India 3-TAMP5 Tamper switch for 3-CAB5.Mounts to side of cabinet. 0.5(.2) T:+91 80 4344 2000 F:+91 80 4344 2050 3-TAMPRCC 3-TAMPRCC Tamper Switch for RCC series cabinets. Mounts to side 0.5(.2) of cabinet. Australia 1. For earthquake anchorage,including detailed mounting weights and center of gravity detail,please refer to T+61 3 92391200 Seismic Application Guide 3101676.Approval of panel anchorage to site structure may require local AHJ, F+61 3 9239 1299 structural,or civil engineer review. Europe T+32 2 725 11 20 F+32 2 721 86 13 Latin America T 305 593 4301 F 305 593 4300 utcfi reandsecu rity.com ©2010 UTC Fire&Security. All rights reserved. 0 v, Page4of4 DATA Si,LL 85010-0067 Not to be used for installation purposes. Issue 10