HomeMy WebLinkAboutA15-0012_F0.1 CON_1450201800.pdf itrte..% e' 11.1110 Z Vail Fire&Emergency Services 12/15/15 FIRE DEPARTMENT USE FIRE ALARM LEGEND SYMBOL DESCRIPTION MODEL BACK BOX 113 FIRE ALARM CONTROL PANEL EST-3 3-CAB-21B:24.12"W x 49.75"H x 3.86"D o aD rn Z C\2 V— cc E3 REMOTE FIRE ALARM CONTROL PANEL EST-3 3-RCC14R:25"W x 36.125"H x 6"D W o CO I� I LCD FSCP FIREFIGHTER SMOKE CONTROL PANEL KIRKLAND RSG TBD x � CI71zco ESE—, CO I co COZI2 COCD ANNU REMOTE ANNUNCIATOR 3-LCDANN RLCM/B:6.12"W x 12.1"H x 2.75"D W cD Z W z E3 GRAPHIC MAP PAPER WITH FRAME TBD 0 Q = w w ® BATTERY CABINET BC-1 18.25'W x 14.0"H x 7.25"Da.. vl A) z BPSx REMOTE POWER SUPPLY BPS6A/BPS10A 13"W x 17"H x 3.375"D ,� \0�� EXAMPLE: DUCT WIDTH=3 ft Ku oc 3 ft x 6=18 ft 131 RADIO ENHANCEMENT AMPLIFIER PROVIDED BY OTHERS PROVIDED BY OTHERS (iir y"1111. OPENINGS,BEND,OR 0P PHOTOELECTRIC SMOKE DETECTOR W/BASE SIGA2-PS,BASE SIGA-SB4 4"SQUARE,2-1/8"DEEP OTHER OBSTRUCTIONS P=Photoelectric PHOTOELECTRIC SMOKE DETECTOR W/SOUNDER BASE 4 in. ABO P P=Photoelectric AB=Sounder Base SIGA2 PS,BASE SIGA-AB4GT 4"SQUARE,2-1/8"DEEP - CEILING CEILING 111iW iAr PHOTOELECTRIC SMOKE/CARBON MONOXIDE DETECTOR W/SOUNDER BASE '111471 \\\\\\\\\\\\\\\\\\\\ ABO PCOSIGA2 PCOS,BASE SIGA-AB4GT 4"SQUARE,2-1/8"DEEP ` �� RECOMMENDEDP=Photoelectric/Carbon Monoxide AB=Sounder Base 6 DUCT WIDTHS MINIMUM 10 DUCT WIDTHS MAXIMUMO HEAT DETECTOR ADDRESSABLE(RATE OF RISE)135 DEGREE SIGA2-HRS,BASE SIGA-SB4 4"SQUARE,2-1/8"DEEP OR AS FAR AS POSSIBLE 135R ACCEPTABLE HERE ACCEPTABLE HERE 4in. I / RETURN AIR OO C135R I HEAT DETECTOR NON-ADDRESSABLE(RATE OF RISE)135 DEGREE CR135-2 OCTAGON BOX Cl)- Ga o / NEVER HERE INLET �� w z �.w w Q rw o W / ��O S �� OO 135R WP HEAT DETECTOR NON-ADDRESSABLE(RATE OF RISE)135 DEGREE,WEATHER PROOF 302-ET-135 STONCO BACK BOX w w E�"o w 61 8 F v � �� �/ wQ Eo�E. o� Cl) TOP OF DETECTOR RECOMMENDED 1 �F ADDRESSABLE MANUAL PULL STATION SIGA-278 4"SQUARE,2-1/8"DEEP, 1-GANG PLASTER RING ate.,E'ai CD Cl)o o / 6 DUCT WIDTHS MINIMUM o H o:a x ACCEPTABLE HERE / 10 DUCT WIDTHS MAXIMUM ra E"Q a o ( : o Cl)o o JIMUM 12in. 12in.MAXIMUM OR AS FAR AS POSSIBLE CF — NON-ADDRESSABLE MANUAL PULL STATION 278B-1120 4"SQUARE,2.1/8"DEEP, 1-GANG PLASTER RING o- r— : ,TOP OF DETECTOR ACCEPTABLE HERE THE RECOMMENDED LOCATION OF SMOKE DETECTORS MOUNTED CC1 SIGNAL MODULE SIGA CC1 4"SQUARE,2 1/8"DEEP,2 GANG PLASTER RING lx E z o U' z w D IN OR DUCT SMOKE DETECTORS MOUNTED ON AIR DUCTS, o z d Q w w N SHOULD BE BETWEEN SIX DUCT WIDTHS AND 10 DUCT WIDTHS Ex n z G. E" lx <4 w C4 w \\ DOWNSTREAM FROM ANY DUCT OPENINGS,DEFLECTION PLATES, CC1 S SIGNAL CONTROL MODULE SYNCHRONIZE SIGA-CC1S 4"SQUARE,2-1/8"DEEP,2-GANG PLASTER RING H 22 o4 CD E'm C q a F x C4 SHARP BENDS,OR BRANCH CONNECTIONS. z F w Cl)Ur2-.o / \ REFER TO NFPA 72,90A,92A AND 92B FOR FURTHER / \ I_ GUIDELINES. CT1 MONITOR MODULE/SINGLE ADDRESSABLE MODULE SIGA-CT1 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING / SIDEWALL \ SIDEWALL #' 1 NOTES: MEASUREMENTS SHOWN ARE TO / NOTE:MEASUREMENTS SHOWN ARE TO THE \ DUCT DETECTORS SHALL BE LOCATED: A.UPSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CT2 MONITOR MODULE/DUAL ADDRESSABLE MODULE SIGA-CT2 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING THE CLOSEST EDGE OF THE DETECTOR. / CLOSEST EDGE OF THE DETECTOR \ CONNECTIONS IN AIR RETURN SYSTEMS OF GREATER THAN 2000CFM. B.AT EACH STORY PRIOR TO THE CONNECTION TO A COMMON RETURN / \ IN AIR RETURN SYSTEMS OVER AND RE-CIRCULATION CULAO TII NO OR CR FRESH AIR INLET CONNECTION CONTROL RELAY MODULE SIGA-CR 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING PROPER MOUNTING FOR SMOKE DETECTORS PROPER MOUNTING FOR HEAT DETECTORS DUCT DETECTOR PLACEMENT 10 INPUT/OUTPUT MODULE SIGA 10 4"SQUARE,21/8"DEEP,1 GANG PLASTER RING MCT2 MODULAR MONITOR MODULE/DUAL ADDRESS MODULE SIGA-MCT2 U10 MOTHERBOARD (/] MCR MODULAR CONTROL MODULE SIGA-MCR UIO MOTHERBOARD Z O U] MCC1 MODULAR SIGNAL MODULE SIGA-MCC1 U10 MOTHERBOARD W MCC1S MODULAR SYNC SIGNAL MODULE SIGA-MCC1S UIO MOTHERBOARD z w U102x 2 SLOT UNIVERSAL INPUT/OUTPUT MODULE MOTHERBOARD SIGA U102/SIGAU102R JUNCTION BOX:MINIMUM 14"W x 8"H x 3.5"D o 1—w W/RISER INPUTS IF x=R w 0 o 6 SLOT UNIVERSAL INPUT/OUTPUT MODULE MOTHERBOARD w a,v U106x SIGA U106/SIGAUIO6R JUNCTION BOX:MINIMUM 14"W x 8"H x 3.5"D ,,;, w W/RISER INPUTS IF x=R w 1-Z >- t....) V Z'w DEVICE MOUNTING GUIDELINES TCDR TEMPORAL PATTERN GENERATOR MODULE SIGA-TCDR 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING co ". x 9'(CEILING) a 0 N a RM1 RISER MONITOR MODULE SIGA-RM1 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING ..w w w SPEAKER w`.)t_.) m SPEAKER/STROBE SPEAKER/STROBE MNS STROBES >CCI.J1 U-1UJ s LLJ W/EXPANDER FIRE HORN/STROBE \ NFPA 72 96" MAX. J CD cc a DH DOOR HOLDER PROVIDED BY OTHERS N/A o 0 0 0 TOP OF DEVICE AT \E_CENTER 4" SQ. BOX WITH EX T 90" A.F.F. ❑ CENTER 4" SQ. BOX — ❑ CENTER 4" SQ. BOX ❑ "P" RING 89" A.F.F. REMOTE LCD w w w w N_N_N_t/l AT 85" A.F.F. AT 84" A.F.F. ANNUNCIATOR PM MULTI-VOLTAGE RELAY PAM-1 N/A >>>ce > 0 —CENTER 4" SQ. BOX WITH �,�,U u, "P" RING 82" A.F.F. BP56A/BPS10A +r`Ln o R REMOTE TEST SWITCH N N N— LOCAL ALARM STROBE BOOSTER PANEL 131 MULTI-VOLTAGE RELAY RIC-1 N/A M v.o o- 0 0 NFPA 72 80" MIN. 72" MAX. — (x-x-x) SYNCHRONIZED STROBE ONLY,WHITE,"FIRE" 60" MIN. G1F-VM(MULTI CANDELA 15,30,75,110) 4"SQUARE,2-1/8"DEEP,1-GANG PLASTER RING pxxW xxW=CANDELA SETTING,WALL MOUNT/(x x x)=ADDRESS(BPS,CKT,DVC) W a m 60" MAX. 5' MAX. I FRCP (x-x-x) SYNCHRONIZED SPEAKER STROBE,WHITE,70 Volt,"FIRE"/xw=WATTAGE SxxW=SPEAKER,CANDELA SETTING,WALL MOUNT/(x-x-x)=ADDRESS(BPS,CKT,DVC) G4F-S7VM(MULTI-CANDELA 15,30,75,110) 4"SQUARE,2-1/8"DEEP NFPA 72 54" MAX. 48" MIN. �. SxxWIn C\2 1 a OR AUDIO PANEL BPS ANNU xw Q Qom'. < F ADA 48" MAX. ` ' ( SYNCHRONIZED SPEAKER STROBE,WHITE,70 Volt,"FIRE"/xw=WATTAGE,WEATHERPROOF WG4WF-SVMC(MULTI CANDELA 15,30,75,110) 449 WEATHER PROOF BACK BOX Q NFPA 72 42" MIN. %o SxxWP SxxW=SPEAKER,CANDELA SETTING,WALL MOUNT/(x x x)=ADDRESS(BPS,CKT,DVC) N. PULL STATION (x-x-x) SYNCHRONIZED SPEAKER STROBE,RED,70 Volt,"FIRE"/xw=WATTAGE e 1 • SxxW SxxW=SPEAKER,CANDELA SETTING,WALL MOUNT/ x x x =ADDRESS(BPS,CKT,DVC) G4RF-S7VM(MULTI-CANDELA 15,30,75,110) 4"SQUARE,2-1/8"DEEP (x-x-x) SYNCHRONIZED SPEAKER STROBE,RED,70 Volt,"FIRE"/xw=WATTAGE,WEATHERPROOF WG4RF-SVMC(MULTI-CANDELA 15,30,75,110) 449 WEATHER PROOF BACK BOX X Sx WP SxxW=SPEAKER,CANDELA SETTING,WALL MOUNT/(x-x-x)=ADDRESS(BPS,CKT,DVC) PARKING LEVELS P1,P2,P3 ONLY V ‘O' H15/75WP 4-WIRE TEMPORAL HORN STROBE,WEATHER-PROOF 757-7A-T 757A-WB ADA 15" MIN. � yW END OF LINE RESISTOR RATING VARIES DEPENDING ON APPLICATION N/A 0 REMOTE TEST SWITCH FOR DUCT DETECTOR: PULL STATION: FLOW SWITCH PROVIDED BY OTHERS N/A 4-1 SHALL BE WALL MOUNTED AT 6' A.F.F. CONTRACTOR SHALL CONFIRM LOCATION WITH OWNER PRIOR TO TO COMPLY WITH BOTH NFPA 72 & ADA ACCESSIBILITY GUIDELINES, MOUNT MANUAL PULL STATION AT INSTALLATION OF DEVICE. 42"-48" ABOVE FLOOR. MEASUREMENT IS FROM FLOOR TO OPERABLE PART OF DEVICE. TAMPER SWITCH PROVIDED BY OTHERS N/A NOTIFICATION DEVICES: ADA ACCESSIBILITY GUIDELINES HAVE ACCEPTED NFPA 72 GUIDELINES AS "EQUIVALENT FACILITATION". H W LA LOW AIR SWITCH PROVIDED BY OTHERS N/A U) U Z X PS PRESSURE SWITCH PROVIDED BY OTHERS N/A U W Hi < UJ U) Z O < cJ 00 E, W � E E- - 0 W - - 4 Code Description Wire Type Color(+) Color(-) (-)Striping QTY Cond/Cables Wire type COND/Cable OD r124 kr) A Annunciator Wiring 2#18 AWG Twisted Pair Cable Red Black None 1 H11802 0.146 w S Notification Appliance(Speaker)Wiring 2#16 AWG Twisted Pair Cable Red L Black Blue 1 I H11602 0.182 rc..,Z u) U x RA Rescue Assist CAT5E Shielded Cable 1 4666804/10 0.345w W q W w M AC 120VAC Power Wiring 3#12 AWG Solid(w/Green Ground) Black White None 3 THHN#12 0.119 O -. Q 0 V Notification Appliance(Strobe)Wiring 2#12 AWG Solid(LEVEL P3,P2,P1 ONLY) Orange Black Orange 2 THHN#12 0.119 — t a Z a Z V Notification Appliance(Strobe)Wiring 2#14 AWG Solid(LEVEL 1-LEVEL 7) Orange Black Orange 2 THHN#14 0.102 X Auxiliary Circuit(Relay)Wiring 2#14 AWG Solid Yellow Black Yellow 2 THHN#14 0.102 L SLC Wiring(Initiating Device Wiring) 2#16 AWG Solid Red Black White 2 TFFN#16 0.094 W p 24V DC Power Wiring 2#16 AWG Solid Green _ Black Green 2 TFFN#16 0.094 Z Indicating Device Circuit Wiring 2#16 AWG Solid Brown Black None 2 TFFN#16 0.094 U? U R Remote Light/Test Wiring 4#18 AWG Solid Purple Black Purple 4 TFFN#18 0.078 �1 O d Z a. 15tF Z z z E O w w 0 W U) Q E~ UD ET-1 (- a ¢ zw John Bauman Nicet Fire Alarm Systems U Level IV Q G[ -‹C 4 U3 1 Certification#101808 Date: PROJECT SHEET TITLE F0 . ' CON