HomeMy WebLinkAboutA15-0021_FA000W_1451332320.pdf ° CliI/4 111; di1111:1,2% X of 0 LEGEND : Arm% Vail Fire&Emergency Services SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 12/28/15 2755 SNOWBERRY,WEST UNIT FACP Ademco Vista20 FACP Fire Alarm Control Panel Honeywell Vista 20P Mount on wall in manufacturer backbox Standby Number of Current Total Current KP Device Type Devices Amps] (Amps) _ LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox Main FACP CPU 1 X 0.085 __- 0.085 4193SN Serial Interface 1 X 0.00015 = 0.00015 Combination Smoke & COSMOD4W Module 3 X 0.052 = 0.156 0 Heat Detector w/Sounder System Sensor i3 series 4WTA-B 4" square box i3 Smoke Detector 4 X 0.0005 = 0.002 i4 Smoke/CO Detector 5 X 0.0005 = 0.0025 Combination Smoke and 6160 Keypad 1 X 0.04 = 0.04 OCo CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box SUM COLUMN FOR STANDBY LOAD 0.28565 = AMPS ® System Sensor 5601 P Heat Detector w/4193SN Addressable module 4" square box Alarm Load z Number of Current Total Current o Approved as noted . Stamped Device Type Devices (Amps) (Amps) © Cosmo Interface Module COSMOD4W Main FRCP CPUDevice X 0.16 0.16 U 4193SN Serial Interface 1 X 0.00015 = 0.00015 w approvedplans and PAPER COSMOD4W Module3X0.075 = 0 225KB Knox Boxpp i3 Smoke Detector 4 X 0.075 0.14 0 FERMITr ke nI i4 SmokelGD Detector 5 X 0.04 = 0 2 wa e to be o job site 6160 Keypad 1 X = 0.1 Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backboxLu Outside Hom/Strobe 1 X 0.195 = 0.195 AT ALL INES . Permit shall b e SUM COLUMN FOR ALARM LOAD 1.02015 = AMPS Standby Load Required Standby Time in Hours Current (Amps) in visible locationprior to °.2865 X 24 - 686 LuH posted Alarm Load Required Alarm Time in Hours Current (Amps) (15 MINUTES) Lc installation .commencement of1.02015 X 0.25 = 0.26 Add Standby and Alarm Load for Required Ampere Hour Battery 7.11 ci Multiply by the Derating Factor of 1.2 D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) Total Ampere Hours Required = 8.53 Batteries Provided: 12AH Minimum X = 2-WIRE DATA, 2-#16AWG 00 w O z N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG °' • Z = 2-WIRE DATA CIRCUIT, 2-#16AWG cn Q EOL EOL o IN l 0 KP = KEYPAD CIRCUITING, 4-#18AWG o 2755 SNOWBERRY WEST UNIT ZONE LIST 7co 2 c) 0 ZONE Type of Device Level Description RISER NOTES: _ rn (f) 001 HEAT DETECTOR MAIN GARAGED D (1) J �; 1. REFER TO PANEL INSTALLATION MANUAL FOR _1 002 SMOKE DETECTOR LOWER LOWER LEVEL SMOKE DETECTOR c w 003 CO DETECTOR LOWER LOWER LEVEL CARBON MONOXIDE MORE INFORMATION. !Lk__ i _c Q 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS 004 SMOKE DETECTOR MAIN 'MAIN LEVEL SMOKE DETECTOR MANUFACTURERS SPECIFICATIONS. NX-8E L,N c LN a- -ti. 005 CO DETECTOR MAIN MAIN LEVEL CARBON MONOXIDE CONTROL PANEL 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) 006 SMOKE DETECTOR UPPER UPPER LEVEL SMOKE DETECTOR PRIOR TO INSTALLATION. WIRING DIAGRAM IS Cr) 007 CO DETECTOR UPPER ,UPPER LEVEL CARBON MONOXIDE INCLUDED SUBMITTAL BOOKS. 4193 Z 0 ® ; ad 008 SPRINKLER WATERFLOW iii 009 SPRINKLER TAMPER 1 20VAC DEDICATED POWER Z (1). . 1e� 010 4193 FLOW SWITCH 4193 Z TAMPER SWITCH E TELEPHONE LINE BELL N r/P 0 EOLR OUTPUT DATA/COM KP L 0 RISER D I AG RA V OUTPUT KEYPAD KEYPAD N } o �' L O 00 GENERAL NOTES: N o ct O 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH o 0 MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. I 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR m o FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, ,, v) PROGRAMMING AND DEVICE OPERATION. CL Il 00 or b.,. T'4, . ,c5.-,4*, r ,,,. IA\f:1'i ,, x rJ. 3523.x; 1,t,ig i ..r. 0_ C PROJECT INFORMATION : z 2755 SNOWBERRY z = SEQUENCE OF Q w w = (n OPERATIONS: N Q } ; 0 0 VAIL COLORADO I- _ LJ Z0 FSo N0 FIRE ALARM SYSTEM J C9 0 OIH Nim Z - v J o � H > H JF cKQ m0 W D "' w "' m "' o o z m o AHJ: VAIL FIRE Sc EMERGENCY SERVICES 0 0 gZ Dz 22 wa mK (7) LL, CO Q Q E m E Hit L E Q I Ism APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC >- F- W (no i0 � o OH o2 OCCUPANCY: GROUP R Q �u„ Z �u„ Z NZ LU I Qo Q� USE: DUPLEX >- DEVICEDESCRIPTION >- zz - z - z - > w > z > z 0 W o Lt0 ' o o < 0 D o o FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM WILL INCLUDE A NEW W < H H H H H H CL Q Q m < �' Q = ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE 00 0 co SMOKE DETECTOR X X X INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON 0 J Q W STAIRWELL LANDINGS AND AREAS OUTSIDE OF SLEEPING ROOMS. A HEAT z 0 J z HEAT DETECTOR X X X DETECTOR WILL BE INSTALLED IN THE GARAGE. DETECTORS HAVE C!) 0 < 0 INTEGRAL SOUNDERS. A KNOX BOX AND OUTSIDE HORN/STROBE WILL Ln J W co CARBON MONOXIDE DETECTOR X X X BE MOUNTED AT THE FDC. THE HOME IS SPRINKLERED AND THE FACP Q W WILL MONITOR FLOW/TAMPER. N > L-L 0 SPRINKLER WATERFLOW SWITCH X X X X FIRE PROTECTION ENGINEER: SHEET DESCRIPTION: DEBORAH SHANER, P.E., SHANER LIFE SAFETY FIRE ALARM PLAN SPRINKLER TAMPER SWITCH X X PO BOX 1073, FRISCO, CO 80443 PHONE: 970-409-9082 DRAWN BY: DATE: POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X FAX: 970-797- 1898 DLS 12/23/15 SHEET#: FA-000W