HomeMy WebLinkAboutA15-0050_FA000_1434731460.pdf t1CliI/4 Zrti11 v. Fire Alarm Legend BUILDING CODE INFORMATION: GENERAL NOTES: j coo SEBASTIAN VAIL, PENTHOUSE UNIT Resistor Color Code Chart Vail Fire&Emergency Services 16 VAIL ROAD 06/19/15 First Band Second Band Third Band Fourth Band SYMBOL PART NUMBER DESCRIPTION MANUFACTURER VAIL, COLORADO Colors Colors Colors CTolors( %) MultiplACPS-610 POWER SUPPLY NOTIFIER GOVERNING CODES Black =0 Black =0 Black x0 ohm Gold =5 ACPS Brown =1 Brown =1 Brown x 10 Silver =10 % Red =2 Red =2 Red x 100 None =20 % - 2012 INTERNATIONAL BUILDING CODE Orange =3 Orange =3 Orange x1,000=Kohm BATT-12120 12 AMP/HOUR BATTERY NOTIFIER - 2012 INTERNATIONAL FIRE CODE Yellow =4 Yellow =4 Yellow x 10,000 Green =5 Green =5 Green x 100,000 - 2010 NATIONAL FIRE ALARM CODE (NFPA 72) Blue =6 Blue =6 Blue x 1,000,000=M ohm FAPT-851 PHOTOELECTRIC SMOKE DETECTOR NOTIFIER Violet =7 Violet =7 Silver /100 OGray =8 Gray =8 Gold /10 SB White =9 White =9 B200S-LF SOUNDER BASE NOTIFIER CLASSIFICATIONS Example:1st� I Band=Yellow,2ndBand=Violet,3rd Band=Red n CO1224TR CONVENTIONAL CARBON MONOXIDE DETECTOR HONEYWELL 1 ) BUILDING OCCUPANCY: First Band h or4 .7Kohm RESIDENTIAL Second Band MM FMM-101 MINI MONITOR MODULE NOTIFIER 2) SPRINKLED: YES Third Band 0<1 SPCW SPEAKER ONLY NOTIFIER JURISDICTION Fourth Band . VAIL FIRE & EMERGENCY SERVICES NU- VAIL, COLORADO Resister Color Code Chart FIRE ALARM DEVICES MUST BE PLACED IN PROTECTED AREAS WITH SCOPE OF WORK AMBIENT TEMPERATURE RANGING FROM 32° TO 120° F. **EXCEPTION: ADDRESSABLE HEAT DETECTOR. FIRE ALARM WORK FOR REMODELED PENTHOUSE UNIT. SCOPE OF WORK INCLUDES: DO NOT PLACE SMOKE DETECTORS WITHIN 6 FEET OF AIR SUPPLY11111 GENERAL NOTES REGISTERS AND DIFFUSERS. • SMOKE/HEAT DETECTORS WITH SOUNDER BASES 1, ALL RACEWAYS SHALL BE 3/4' CONDUIT MINIMUM, • CARBON MONOXIDE DETECTORS WITH ADDRESSABLE MONITOR MODULES ALL INTELLIGENT DEVICES SHALL BE INTERCONNECTED AS SHOWN 2. ALL CABLING WILL BE PULLED THROUGH J-BOXES WITH❑UT SPLICES. • SPEAKERS FOR AUDIBILITY ON THE ONE-LINE DIAGRAM. EACH INTELLIGENT DEVICE 3. ALL CABLING WILL BE PULLED FROM DEVICE TYPE TO NEXT DEVICE TYPE L❑CATI❑N • NEW ACPS POWER SUPPLY FOR SOUNDERS IS DESIGNATED WITH AN ADDRESS. T-TAPPING IS PERMITTED WITH NO SPLICES. WHEN CONDUIT SYSTEM IS BEING INSTALLED, ALL WIRES SHALL BE ON SLC LOOP (CLASS "B" STYLE 4) ONLY. PULL THROUGH THE BOX OTHER THAN DEVICE TYPE BEING CONNECTED, SPEAKER WILL BE CONNECTED TO THE EXISTING VOICE CIRCUIT ON THE FLOOR. 4. ANY DEVICES INSTALLED LESS THAN 96' SHALL HAVE A RACEWAY DETECTORS AND MODULES WILL BE CONNECTED TO THE EXISTING SLC CIRCUIT WIRE RUNS SHOW INTERCONNECTION OF FIRE ALARM DEVICES ONLY. 5, ANY PENETRATI❑NS THROUGH FIRE RATED AND OR STRUCTURAL MEMBRANES WALL SHALL ON THE FLOOR. SOUNDERS AND CO DETECTOR POWER WILL BE RUN FROM THE WIRING DOES NOT REPRESENT CONDUIT RUNS. BE SLEEVED AND FIRE STOPPED, NEW ACPS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER LO Q0 CONNECTION OF EQUIPMENT PROVIDED BY OTHERS. CiD I REMOTE POWER SUPPLY (POWER SUPERVISION): Hi I ` J *PER (NFPA) NATIONAL FIRE ALARM CODE 72 2010 EDITION Il CO AMBIENT TEMPERATURE RANGING FROM 32° TO 120° F. **EXCEPTION: UNLESS MANUFACTURES INSTALLATION INSTRUCTIONS N STATES OTHERWISE. • "* '-- Stamped approvedplans to be kept onjob site 4.4.7 MONITORING INTEGRITY OF INSTALLATION CONDUCTORS AND a--� ,, ..4.�- 4i , p pp p 0 --� * r ••ci�6 k:,� OTHER SIGNALING CHANNELS. 0 . , 4rz , and available for inspections. I 'n�;� i'; .,,. ,1 4.4.7.1.1-13 ALL MEANS OF INTERCONNECTING EQUIPMENT, DEVICES, Oc ,. :r.- o wxs 35235 �,w : - AND APPLIANCES AND WIRING CONNECTIONS SHALL BE p—'--4 (telCY) 1:::'.. '� „ MONITORED FOR THE INTEGRITY OF THE INTERCONNECTING �-' �� CONDUCTORS OR EQUIVALENT PATH SO THAT THE OCCURRENCE �/� -.y1 Q0 ..' '.€, OF A SINGLE OPEN OR A SINGLE GROUND-FAULT CONDITION V 1 k ..........' ..''. IN THE INSTALLATION CONDUCTORS OR OTHER SIGNALING 0 CHANNELS AND THEIR RESTORATION TO NORMAL SHALL BE O AUTOMATICALLY INDICATED WITHIN 200 SECONDS. EXCEPT. INTERCONNECTION BETWEEN ENCLOSURES CONTAINING C NO. 8 CONTROL EQUIPMENT LOCATED WITHIN 20ft (6m) WHERE THE 1.4 Q; If) CONDUCTORS ARE INSTALLED IN CONDUIT OR EQUIVALENTLYCY) Z PROTECTED AGAINST MECHANICAL INJURY. 0 AUDIBLE REQUIREMENTS: p C ao (REFER TO NFPA 72 CHAPTER 7: SECTION 7.4.2) N PUBLIC MODE AUDIBLE REQUIREMENTS SCI cJ SECTION 7.4.2.1 - TO ENSURE THAT AUDIBLE PUBLIC MODE SIGNALS 0 ARE CLEARLY HEARD, THEY SHALL HAVE A SOUND LEVEL AT LEAST ^y O 15dBA ABOVE AMBIENT SOUND LEVEL OR 5dBA ABOVE THE MAXIMUM 0 r `I * SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, N. ,z: , Note 1. Heights shown are listed in NFPA 72 Standards 2010 WHICHEVER IS GREATER, MEASURED 5ft (1.5m) ABOVE THE FLOOR ..7 O Note 2. Where ever devices are indicated to be above doors, the device shall be centered IN THE OCCUPIABLE AREA. ^te "�I between top of door trim and ceiling line. Note 3. These are NFPA listed Mounting heights, and any mounting heights listed in the DRAWING NOTES: Specifications or shown on the Architectural Elevations shall govern over those shown here. Any discrepancy shall be approved by the Engineer of Record. ALL WIRING RUNS SHOWN ON THE FIRE ALARM SHOP DRAWINGS ARE w Note 4. Remote Lights and Remote Test Switches shall be mounted on the wall directly below CONCEPTUAL ONLY. THEY DO NOT AND ARE NOT INTENDED TO BE Cip the device that it is connected to and shall be seen clearly from the floor. ACTUAL WIRE RUNS OR CONDUIT RUNS. DEVICE INTERCONNECT IS Note 5. Control modules and monitor modules shall be mounted as to be accessible, above INTENDED TO SHOW ONLY SEQUENCE OF DEVICE CONNECTIONS AND easy reach as to prevent vandalism (EXCEPTION: DEVICES INSTALLED IN ROOMS TYPE OF WIRE. CD I 1--1 NOT ACCESSABLE BY THE GENERAL PUBLIC). PLEASE REVIEW BOTH THE FLOOR PLANS AND THE RISER DIAGRAM =j CiD Z Note 6. Per manufacturers recommendation. DRAWINGS TO RESOLVE ANY CONFLICTS OR QUESTIONS THAT MAY C. For additional placement restrictions, see NFPA 72 Standards 2010. COME UP. IF THE DRAWINGS DO NOT ANSWER YOUR QUESTIONS, PLEASE CALL CSWC FIRE SYSTEMS FOR HELP TO ANSWER YOUR QUESTIONS. Z U.O.N. ALL VERITICAL RISER CONDUIT SHALL BE NO LESS THAT 3/4". W I I Bottom of Combination c14 O AUDIBLE/VISUAL Device or Individual VISUAL Device �� ® PROTECTED PREMISES F.A. SYSTEMS (WIRING): IDC - Initiating Device Circuit � 1:4 x Manual Stations, Smoke Detectors, Etc. ^ H 124 Bottom of VISUAL devices < , = z 0 in ADA Units ® Style B (Class B) a F ® e..1—I I a Bottom of Horn/Strobe r { a & Strobe only J-Boxes J❑ SLC — Signaling Line Circuit A Intelligent Devices. Q e, See Note#4 &#5 Top of Device IA RM MM III �M Style 4 (Class B) F ® F O II ("T" Tap) n� Top of Cabinet Hi w FACP NAC - Notification Appliance Circuit Cl) 24" below Horns, Bells, Strobes, Etc. 6'-8" ceiling c=1 (24 4'4 (80") 6'-7" Style Y (Class B) O_ (79") Approx. CipLA 7'-0" Top of Unit I _ � (84") 6'-0" MAP LCD W 1--I (72") WIRE CHART To Handle of Device E = Wire runs are indicated by AlphaNumeric designations. For HI example: 5'-4" (64") "ADA" The wire Gauge of any wire run is determined by the / 4'-0" length of the wire run and the power load on that run. /DRAWN DLS (48") All heights measured A CHECKED TW from (AFF) Above A typical wire run designated as "A", would refer to a ' Finished Floor single run of"2 #_" cable. DATE 5/205 2A T ical Device Mountie Hei ht SHEET A designation of 2A , would refer to a run of 2 FAO. 00 ypg g pair, 2#_" cable. # OF SHEETS 3