HomeMy WebLinkAboutA15-0050_FMM_1432758480.pdf DN-6720:C•H-220 FMM-1 (A), FMM-101 (A), NOT 1 F 1 ER® FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan® by Honeywell Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- - ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and 11, •°-" , i power a circuit of two wire smoke detectors(FZM 1(A)). ® E Eo 0 - FM FMM-1(A)is a standard-sized module(typically mounts to a 4" AcCESSoRy ".._•""•E"= [10.16 cm]square box)that supervises either a Style D (Class 1 SLC)r1 A) or Style B(Class B)circuit of dry-contact input devices. � .•s " FMM-101(A)is a miniature monitor module a mere 1.3" (3.302 • cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super— vises a Style B (Class B) circuit of dry-contact input devices. 114 Its compact design allows the FMM-101(A)to be mounted in a single-gang box behind the device it monitors. FZM-1(A)is a standard-sized module that monitors and super- vises compatible two-wire,24 volt,smoke detectors on a Style 411k, , ' D(Class A) or Style B(Class B)circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, FMM-1(A)(Type H) consecutive addresses in intelligent,two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor tocol developed by NOTIFIER that greatly increases the speed (provided) terminates the Style B circuit. No resistor is of communication between analog intelligent devices. Intelli- required for supervision of the Style D circuit. gent devices communicate in a grouped fashion. If one of the FMM-1(A) OPERATION devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The Each FMM-1(A) uses one of the available module addresses net effect is response speed greater than five times that of on an SLC loop. It responds to regular polls from the control other designs. panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates FMM-1(A) Monitor Module that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- • Built-in type identification automatically identifies this device tions on the loop). as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power FMM-1(A) SPECIFICATIONS required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI) immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 350 pA (LED flashing), 1 com- • Direct-dial entry of address: 01 — 159 on FlashScan loops; munication every 5 seconds,47k EOL. 01 —99 on CLIP loops. Maximum IDC wiring resistance:40 ohms. • LED flashes green during normal operation (this is a pro- EOL resistance:47K ohms. grammable option) and latches on steady red to indicate alarm. Temperature range: 32°F to 120°F(0°C to 49°C). The FMM-1(A) Monitor Module is intended for use in intelli- Humidity range: 10%to 93%noncondensing. gent, two-wire systems, where the individual address of each Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built-in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x vides either a two-wire or four-wire fault-tolerant Initiating 2.125" (5.398 cm)deep box. Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B) or Style D (Class DN-6720:C•10/06/2010—Page 1 of 4 FMM-101(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65"(1.651 cm)deep. • Built-in type identification automatically identifies this device as a monitor module to the panel. Wire length:6" (15.24 cm) minimum. • Powered directly by two-wire SLC loop. No additional power required. FZM-1(A) Interface Module • High noise(EMF/RFI) immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on FlashScan loops; source. 01 —99 on CLIP loops. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 14• 15 0 1 ADDRESS 0 1 • Direct-dial entry of address: 01 —159 on FlashScan loops, • 13 2 \ 2 01 —99 on CLIP loops. 123 LOOP 3 • LED flashes during normal operation;this is a programma- 11 4 �4 ble option. 10 9 6 9 6 5 • LED latches steady to indicate alarm on command from 8 7 8 7 control panel. TENS ONES The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status(nor- Lu mal, open, or alarm)of one full zone of conventional detectors 0 CC UJ > m back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. I FZM-1(A) APPLICATIONS The FMM-101(A) Mini Monitor Module can be installed in a Use the FZM-1(A)to monitor a zone of two-wire smoke detec- single-gang junction directly behind the monitored unit. Its tors. The monitored circuit may be wired as an NFPA Style B small size and light weight allow it to be installed without rigid (Class B)or Style D (Class A) Initiating Device Circuit.A 3.9 K mounting. The FMM-101(A) is intended for use in intelligent, ohm End-of-Line Resistor(provided)terminates the end of the two-wire systems where the individual address of each module Style B or D (class B or A) circuit (maximum IDC loop resis- is selected using rotary switches. It provides a two-wire initiat- tance is 25 ohms). Install ELR across terminals 8 and 9 for ing device circuit for normally-open-contact fire alarm and Style D application. security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FZM-1(A)OPERATION FMM-101(A) Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control Use to monitor a single device or a zone of four-wire smoke panel and reports its type and the status (open/normal/short) detectors,manual fire alarm pull stations,waterflow devices,or of its Initiating Device Circuit (IDC). A flashing LED indicates other normally-open dry-contact devices. May also be used to that the module is in communication with the control panel. monitor normally-open supervisory devices with special super- The LED latches steady on alarm (subject to current limita- visory indication at the control panel. Monitored circuit/device tions on the loop). is wired as an NFPA Style B(Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPECIFICATIONS cuit. Nominal operating voltage: 15 to 32 VDC. FMM-101(A)OPERATION Maximum current draw:5.1 mA(LED on). Each FMM-101(A) uses one of the available module Maximum IDC wiring resistance:25 ohms. addresses on an SLC loop. It responds to regular polls from Average operating current: 300 pA, 1 communication and 1 the control panel and reports its type and the status(open/nor- LED flash every 5 seconds,3.9k eol. mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Average operating current: 350 pA, 1 communication every maximum. Current: 90 mA per module maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Temperature range: 32°F to 120°F(0°C to 49°C). Shorted). Humidity range: 10%to 93%noncondensing. Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Voltage: 11 Volts. 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Current:400 pA. 2.125" (5.398 cm)deep box. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6720:C•10/06/2010 FDM1(A) Dual Monitor Module -161.002/23/3(AFP-200: FMM-1/-101, FZM-1) The FDM-1(A) Dual Monitor Module is intended for use in intelli- -161.002/42/1 (NFS-640: FMM 1/ 101) gent, two-wire systems. It provides two independent two-wire • Lloyd's Register: initiating device circuits (IDCs) at two separate, consecutive —03/60011/E1 (FMM-1/-101, FZM-1) addresses. It is capable of monitoring normally open contact fire —94/60004/E2(AFP 200:except FDM-1) alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- —02/60007(NFS-640: FDM-1) controlled LED. • FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 NOTE:The FDM-1(A) provides two Style B (Class B) IDC circuits (NFS2-3030) ONLY. Style D (Class A) IDC circuits are NOT supported in any application. Product Line Information FDM-1(A)SPECIFICATIONS NOTE:"A"suffix indicates ULC-listed model. Normal operating voltage range: 15 to 32 VDC. FMM-1(A): Monitor module. Maximum current draw:6.4 mA(LED on). FMM-1 01(A): Monitor module, miniature. Average operating current: 750 pA(LED flashing). FZM-1(A): Monitor module,two-wire detectors. Maximum IDC wiring resistance: 1,500 ohms. FDM-1(A): Monitor module,dual,two independent Class B cir- Maximum IDC Voltage: 11 Volts. suits. Maximum IDC Current:240 pA SMB500:Optional surface-mount backbox. EOL resistance:47K ohms. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. ACAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box.They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:0219 • MEA:457-99-E • U.S.Coast Guard: DN-6720:C•10/06/2010—Page 3 of 4 FlashScan®and NOTIFIER®are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTF E We cannot cover all specific applications or anticipate all requirements. ENGINEERING&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6720:C•10/06/2010