Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A15-0050_SPEAKER_1432758480.pdf
SYSTEM �V SENSOR '' **'.::��:. ••••• .•+ a.'. Indoor Selectable- • 0Flak` Output Speaker •. " .�:�. Strobes and Dual a ••' ...a.aa a'•.r•.u«. a.•.a ........................... }1 Voltage Evacuation ' •. AAA11{ + •' •a.a.••.•.•.•r..• ice' Speakers for Ceiling •.•i•.'.moi�•�+' �•' 'J Applications SpectrAlerl°Advance selectable-output speaker strobes �y and dual-voltage evacuation speakers can reduce ground SPECTRIert faults and enable faster installation. / A N c Features The SpectrAlert Advance Series of speakers and speaker Plug-in design and protective cover reduce ground faults strobes reduce costly ground faults using a plug-in design and • universal mounting plate that allow the installer to pre-wire mounting • Universal mounting plate with an onboard shorting spring tests plates,dress the wires,and confirm wiring continuity before plugging wiring continuity before installation in the speakers. In addition,a protective plastic cover prevents • No extension ring required nicked wires by covering exposed speaker components. • Field selectable candela settings: Standard: 15, 15/75,30,75,95, 110, 115 These devices also enable faster installations by providing instant High: 135, 150, 177, 185 feedback to ensure that wiring is properly connected,rotary switches to select voltage and power settings,and 11 field-selectable candela • Automatic selection of 12-or 24-volt operation at 15 and settings for both wall and ceiling speaker strobes. 15/75 candela • Rotary switch simplifies field selection of speaker voltage(25 The low total harmonic distortion of the SP speaker offers high fidelity and 70.7 Vrms)and power settings(1/4,1/2, 1 and 2 watts) sound output while the SPV speaker offers high volume sound output • SP speakers offer high fidelity sound output for use in high ambient noise applications. • SPV speakers offer high volume sound output SpectrAlert Advance makes installation easy • Compatible with System Sensor synchronization protocol •Attach a universal mounting plate to a 4 x 4 x 21i8 inch back box. Electrical compatibility with existing SpectrAlert products Flush mount applications do not require an extension ring. • •Connect the notification appliance circuit or speaker wiring to the • Tamper-resistant construction terminals on the mounting plate. • Listed for ceiling or wall mounting •Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Agency Listings SIGNALING 0 ® MEA LISTED approved S4048 7320-1653:201 10-08-E SpectrAlert Advance Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 2178-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also, SpectrAlert Advance speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified, unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 21i8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 2.8 in,71 mm SPCV Speaker 6.8 in, 173 mm 2.9 in,74 mm With Surface Mount Back Box 6.9 in, 175 mm 3.4 in,86 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in,71 mm SPSCV Speaker Strobe 6.8 in, 173 mm 2.9 in,74 mm With Surface Mount Back Box 6.9 in, 175 mm 5.325 in, 135 mm Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 V DC/FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz Power 1/4,1/2, 1,2 watts UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant(dBA CO 10 ft.) 2W 1W '/s W 1/4 W Ceiling-Mount SPC Series 86 83 80 77 Ceiling-Mount SPCV Series 90 87 84 81 Ceiling-Mount SPSC Series 85 82 79 76 Ceiling-Mount SPSCV Series 89 86 83 80 Dimensions 6.81- - .97j-1.96"= 6.81 "" -97=f-1 .841- ..* , - 000 °°00000 opOo � o°o°o°o�cso o°e°e°o o ao 000 00000000000000°°0000 I °° °°°°° o°o000000oo°o000000000000oo°00000000000000 0 0 O00000000000 \ 00 \00000o°°o 0°00 °00000 1 Ell - �I 00°1:8 000000000000000000 �II orsEcg4 e00000 000000 000°o°o°Oo°o°ooioc/ 00000p0e°00000°0°0°0° 000000pO o 000000000 000000°°O°°0 0 0 000 0 °0°00 00000 0 0°0°°°0°0° •—• a0 p000000 00000 \ o001::: °°000°eoo°o°o° 0 o°�o°Oo°o°oo°0000 o° o o°0000°°o°°°°o° `°Oo°°oo°o°o°o°°o' °�° o°000°°°°°o' Ceiling-Mount SPV Speaker Ceiling-Mount SP Speaker 2.83"" 6.81 - 1.60""I 1.84" -- / 6® 0 o°°o°O ge 4-::::g°0°08318 °e°o iso°o°ooop o°oo i in 00000o -_ _ 4( o0o0o 0o0o0 o oo00 0 0°i o°o 000000 0000° 111111i 000000 ooe000 000000 000000 000aoo I ooe000 000000 000000 'Ii 000000 000000 00000 00000 00000 00000„ •-- 00000\ 00000 09009 \ 000°0. 000 00000: 00000000 , 0000 0O4_ 000°o° .—.000000, 0 00°000°00000 u oOOpo00000 o0 ®° Ceiling-Mount SPS Speaker Strobe Surface Mounting Alikr" �," \ 141400A mmno ° o00o000,°0'I • 00o0 mr,00o0c oo M /0 rli�� Ili o{ 00 \ \l` �,■ omo0oao00oO• oo ' opoo, 0 o°oM o• ° INL /u iia �_ : o _ (imh„ „ ...Ceiling-Mount Speaker with SBBCR/SBBCW Surface Mount Back Box Skirt Ordering Information for SpectrAlert®Advance Speakers and Speaker Strobes Ceiling Mount White Red Description SPCW SPCR Speaker only SPCWV SPCRV Speaker only,High dB SPSCW SPSCR Speaker Strobe,Standard cd SPSCW-P — Plain Speaker Strobe,Standard cd SPSCWH SPSCRH Speaker Strobe,High cd SPSCWH-P — Plain Speaker Strobe,High cd SPSCWV SPSCRV Speaker Strobe,Standard cd,High dB SPSCWV-P — Plain Speaker Strobe,High Volume,Clear Lens,White SPSCWVH SPSCRVH Speaker Strobe,High cd,High dB SPSCW-CLR-ALERT — Speaker Strobe, Standard cd,Clear Lens Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBCW SBBCR Surface Mount Back Box TRCW TRC Ceiling Mount Trim Ring Notes: All-P models have a plain housing(no"FIRE"marking on cover) "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. $� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2015 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR` for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS11102.2/15