HomeMy WebLinkAboutA15-0031_FA000W_1433970000.pdf '44° 111; di1111' 'IA X LEGEND : oj 055 SYMBOL DEVICE MANUFACTURER/PART# MOUNTING ion FACP Caddx (NetworkX) NX-8E Vail Fire&Errergency Services 06/10/15 Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox QPhotoelectric Smoke Detector ESL 541CSRH (w/integral sounder with Integral Sounder w/SI-ID Addressable Module 4" square box Address Type of Device Level _Description Reviewed for code compliance. 001 MONITOR POINT 1 SPRINKLER WATERFLOW Okay for install. O System Sensor 5601 002 MONITOR POINT 1_SPRINKLER TAMPER Heat Detector w/SI-ID Addressable Module 4" square box 003 SMOKE DETECTOR 1 LOWER ENTRY HALL 004 CO DETECTOR 1 LOWER ENTRY HALL 005 HEAT DETECTOR 1 GARAGE Battery Calculations 111 Carbon Monoxide Sensors System Sensor C01224T w/2192 Single gang box Z 006 SMOKE DETECTOR 2 WEST BEDROOM Caddx NX-8E o I- 007 CO DETECTOR 2 HALLWAY Standby 008 SMOKE DETECTOR 2 HALLWAY Number of Current Total Current KB Knox Box 0 009 SMOKE DETECTOR 2 EAST BEDROOM Device Type Devices (Amps) (Amps) o Main FACP CPU 1 X 0.075 = 0.075 p Horn/StrobeSystem Sensor P2RK 4" square box z 010 SMOKE DETECTOR 3 FAMILY ROOM NX-14E LCD Keypad 1 X 0.075 = 0.075 O4 Weatherproof y q 011 CO DETECTOR 3 FAMILY ROOM - 012 SMOKE DETECTOR 3 WEST BEDROOM 541 Smoke Detector 9 X 0.00007 = 0.00063 SI ID Addressable Module 19 X 0.00025 = 0.00475 W 013 CO DETECTOR 4 MASTER SUITE - 001224T Carbon Monoxide Detectors 7 X 0.02 = 0.14 014 SMOKE DETECTOR 4 MASTER SUITE SUM COLUMN FOR STANDBY LOAD 0.29538 = AMPS 015 SMOKE DETECTOR 4 TOP OF STAIRS Alarm Load 016 CO DETECTOR 4 TOP OF STAIRS Number of Current Total Current 017 SMOKE DETECTOR 4_LIVING ROOM Device Type Devices (Amps) (Amps) GENERAL NOTES: 018 CO DETECTOR 4 LIVING ROOMn ' = w 019 CO DETECTOR 4 KITCHEN NX-14ElLCD CPU 1 X 0.14 = 0.14 Keypad 1 X 0.11 0.11 0 020 541 Smoke Detector with sounder 9 . X 0.04 - = 0.36 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN 021 SI ID Addressable Module 19 ' X 0.003 ' = 0.057 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE 022 C01224T Carbon Monoxide Detectors 7 ' x 0.04 = 0.28 DEPARTMENT REQUIREMENTS AND NFPA 72. o 023 Outside Horn/Strobe 1 x 0.212 = 0.212 2. REFER TO MANUFACTURERS DATA SHEETS AND I Z 024 SUM COLUMN FOR ALARM LOAD 1.159 ' = AMPS INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION 025 - Standby Load Required Standby Tme in Hours 026 Current (Amps) REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, CN o w 027IZ 0.29538 X 24 = 7.09 PROGRAMMING AND DEVICE OPERATION. 0 028 Alarm Load Required Alarm Time in Hours I (n 029 Current (Amps) (15 MINUTES) 0p Q U 030 1.159 X 0.25 = 0.29 >% 0) d O 031 Add Standby and Am Load for Required SEQUENCE 0 F Q J 032 Ampere Hour Battery7.38 z Multiply033 b the DeratingFactor of 1.2 • Z J O J 034 Total Ampere Hours Required = 8.85 OPERATIONS : ( J Z N L w 035 Minimum Battery Size Provided: 1 12AH J 6 O (7) O ,>- O 4- 0 0 Q 036 m w 0 Q w Q OO Q o 0 c= 037 0 D g &) m c% > v~) C3 C 038 < o o cK CD 0 CC 0 0 039 U , I- ? m < E I- Z N E 040 ON 0O O 0 1- O 1- OO 1_ I- C Z z z as) NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS ❑ESCRIPTION. O O N O N O W DEVICE Q Q 8 Q DESCRIPTION I I ct I 55, g 0 ' 0 g 0 % E < a F- < I 1- 1- 1- 1- �. - 0 SYSTEM SMOKE OR HEAT DETECTORS X X X 4- 0 Iii SPRINKLER WATERFLOW X X X X (1) 0 - 0 d- SPRINKLER TAMPER X X C 1- d- i1 0O o CARBON MONOXIDE DETECTOR X X X C) N a r - ct o O AC POWER LOSS X X U xo 0 m U (/) GROUND FAULT X X o E 0_ u- OPEN CIRCUIT X X DATA LOOP TO NEXT (2-#18) DEVICE SI-ID SI-ID ADDRESSABLE ADDRESSABLE MODULE MODULE IZONE WIRING I ZONE WIRING POWER CKT ESL 541 2-WIRE TO NEXT PROJECT I \ FO R IV AT I 0 N . o (4-#18) SMOKErn DETECTOR DETECTOR DEVICE S \ OWBERRY DUPLEX - WEST UNIT i..0 2754 SNOWBERRY DRIVE o 0_ DATA/POWER LOOP DETAIL VAIL, COLORADO O le / U FRE ALARM SYSTEM J Q AHJ: VAIL FIRE & EMERGENCY SERVICES Q W = WAPPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC > 0 ® co EOLR USE: DUPLEX LU Q (1 typ) (9 typ) (7 typ) i2 FIRE ALARM SYSTEM FOR WEST UNIT OF DUPLEX. SCOPE OF WORK0 120VAC DEDICATED POWER BELL INCLUDES: 0 0 m CADDX OUTPUT 4 EOLR I— I- W CONTROLSE PANEL (1 typ) • NEW ADDRESSABLE FACP 0 0 TELEPHONE LINE • SMOKE DETECTORS WITH SOUNDERS IN SLEEPING ROOMS, AREAS J W C 13 OUTSIDE OF SLEEPING ROOMS AND AT FACP • HEAT DETECTORS IN GARAGE ct m 2 co DATA/COM CADDX • SPRINKLER SYSTEM MONITORING 0 OUTPUT - NX 148 KEYPAD • OUTSIDE HORN STROBE W 0 < w • CARBON MONOXIDE DETECTORS MONITORED BY FACP CO z Q o RISER DIAGRAM 0 LO Q w — KEYPAD CIRCUITING, 4–#18AWG FIRE PROTECTION ENGINEER: ;.. �_. 4 (/) N RISER NOTES: 4 WIRE DATA/POWER, 4–#16AWG (2 PAIR) SHANER LIFE SAFETY i'`Q;' ; 1G loss- SHEET DESCRIPTION: DEBORAH SHANER, P.E., 1. REFER TO CADDX NX-8E INSTALLATION MANUAL FOR MORE PO BOX 1073, FRISCO, CO 804430'� 3 .a:. WEST UNIT INFORMATION. — — — — 2 WIRE SOUNDER CIRCUIT, 2–#18AWG PHONE: 970-409-9082 - °e 35233i' rro L 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS MANUFACTURERS FAX: 970-797- 1898 t.: 6_,/,2!:.L' SPECIFICATIONS. '.6.4„,„_\•. ,.. DRAWN BY: DATE: � s �" DLS 3/31/15 SHEET#: FA-0.00W