NetworX Control Panels Models NX-4, NX-6, NX-8 -_ • and NX-8E - • l OVERVIEW STANDARD FEATURES The NetworX line of control panels represent a full-featured •Flash memory microprocessor security system that uses advanced technology for burglary,fire •Expanded event log and environmental detection.A highly flexible security option that •Early open/late close reporting is both easy to install and simple to use,NetworX control panels •Programmable loop response can accommodate smaller residential applications up to the most •Accommodates multiple user codes from 8 up to 240 demanding commercial security needs.The series includes the •Up to 8 true partitions with separate account codes,entry/exit delays NX-4,NX-6,NX-8 and NX-8E control panels. and feature selections for each partition •Up to 512-event history log that provides date,time,event and Outstanding features user number Offering up to eight standard hardwire zone inputs,the control •Supports SIA and contact ID communication formats panels also provide four programmable outputs that can be set up •2-wire or 4-wire smoke detector compatibility to activate external devices during an alarm or other system event. •CP-01 2000 compliant The modular design allows for complete integration of multiple systems within one enclosure,and adding more zones or expanding In addition,NX-8E control panel also offers capability is fast and easy.With the addition of a Z-Wave®enabled •Fire alarm verification for greater false alarm immunity Cellular Module,with service from Alarm.com,control of automated •Dynamic battery test lights,door locks,thermostats and more is available using almost •Standard RS-232 on-board interface any Web enabled device. Convenient and flexible Users can conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface.Off-site programming is also available with DL-900 software for Windows. NX-4 Four hardwire zone inputs,expandable to 8 fully programmable hardwire and/or wireless zones NX-6 Six hardwire zone inputs,expandable to 12 fully programmable hardwire or 16 wireless zones NX-8 Eight hardwire zone inputs,expandable to 48 fully programmable hardwire and/or wireless zones NX-8E Eight hardwire zone inputs and two relays,expandable to 192 fully programmable hardwire and/or wireless zones interlogix.com NJ etwo rX North America Asia Australia EuropeLatin America T 855-286-8889 T 852-2907-8108 T 61-3-9239-1200 T 32-2-725-11-20 T 561-998-6114 Control Panels Models NX-4, NX-6, NX-8 and NX-8E Specifications Description NX-4 NX-6 NX-8 NX-8E Standard hardwire zones 4 6 8 8 Maximum hardwire zones 8 12 48 192 Maximum wireless zones 8 16 48 192 Partitions 1 2 8 8 Event log 185 512 User codes 8 40 99 240 Smoke loop 4-wire only 2-wire/4-wire Built-in siren driver 2 Tone(Steady&Yelp) Operating power 16.5VAC,40VA Auxiliary power 1 Amp 2 Amp Operating temperature 0°C to 49°C(32°F to 120°F) Dimensions(H x W x D) 8.3 x 9.3 x 3.5 in. 11.3 x 11.3 x 3.5 in. Regulatory UL365,609,985,1023,1610,1635,1637 CAN/ULC-S303-M91;S545-M89;ORD-C1023-1974 Ordering Information Accessories Four Hardwire Zone Inputs,Expandable 600-1023 Transformer, 16.5VAC,40VA NX-4 to 8 Fully Programmable Hardwire and/or NX-320E Smart Power Supply and Bus Extender Wireless Zones Six Hardwire Zone Inputs,Expandable NX-148E LCD Keypad NX-6 to 12 Fully Programmable Hardwire or NX-148E-RF LCD Keypad w/Integrated 48-Zone Wireless Receiver 16 Wireless Zones NX-548E 48-Zone Wireless Receiver Eight Hardwire Zone Inputs,Expandable NX-8 to 48 Fully Programmable Hardwire and/or NX-582E AES Long-Range Radio Interface Module Wireless Zones NX-584 Home Automation Interface Module with RS-232 Eight Hardwire Zone Inputs and Two Relays, NX-590NE TCP/IP Module NX-8E Expandable to 192 Fully Programmable Hardwire and/or Wireless Zones NX-591 NE-GSM 3G/4G GSM Module(Multi-Carrier) NX-592E-GSM-ZX-AT Alarm.com 3G/4G GSM Module w/Z-Wave®AT&T" NX-592E-GSM-ZX-TM Alarm.com 3G/4G GSM Module w/Z-Wave,T-Mobile® NX-592E-CDMA-ZX-VZ Alarm.com CDMA Module w/Z-Wave,Verizon®Wireless interlogix d interlogix.com Z-Wave®is a registered US trademark of Zensys A/S. Complies with FCC and Industry Canada regulations. Specifications subject to change without notice. ©2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate,Controls&Security, a unit of United Technologies Corporation. 302-3631 2013/06 (73841) NetworX Wireless LCD DisplayKeypad71:1 OVERVIEW STANDARD FEATURES The NetworX wireless LCD display keypad is an integrated 48-zone •Integrated 48-zone wireless receiver wireless receiver LCD keypad with traditional design and an easy-to- •Optimize wireless reception by having the keypad/receiver read,customizable display. It is compatible with all NetworX in the best location control panels. •LCD,easy-to-read programmable display •Traditional design to go with any decor The NetworX wireless LCD display keypad offers the convenience •Compatible with all NetworX series control panels of having an integrated wireless receiver built into the keypad along •Easy to install,program and maintain with standard hardwire features.A removable door allows the user to swing the door down or simply take it off for use.The emergency Specifications keys are highlighted on the keypad and can be programmed to Electrical contact and send complete information to a responding police,fire Current 75mA maximum or EMS unit with just one touch.There are also five pre-programmed Wireless touch keys that allow the most common functions to be performed Frequency 319.5MHz with ease.All keys are backlit to ensure error-free operation —even Range 600ft.(183m)open air in a dark room. Environmental The NetworX wireless LCD display keypad is cost-effective and easy Operating temperature 32°F-120°F(0°C-49°C) to install.Designed for functionality and compatibility,it's the right Physical keypad to fit any application. Dimensions(HxWxD) 5.3 x 6.2 x 1.1 in.(135 x 157 x 27 mm) Construction ABS plastic Color White Ordering Information NX-148E-RF NetworX 48-Zone LCD Display Keypad w/Door and Integrated Wireless Receiver interlogix interlogix.com Specifications subject to change without notice. ©2014 United Technologies Corporation. North America All rights reserved. T 855-286-8889 Interlogix is part of UTC Building&Industrial Systems, Latin America a unit of United Technologies Corporation. T 561-998-6114 305-3662 2014/03 (74998) SYSTEM SENSOR • i4 Series . . Combination CO/Photoelectric w Smoke Detector • f1 • Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than • Single device for CO and smoke detection that uses less wiring two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 Interface Module. easily replaced at end-of-life, resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The • base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station. Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms, reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. ,T U o 4, rt LISTED S268 1653:0227 i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal: 12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 pF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4",3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Interface 11i and Reversing • Y Relay Module • • 4 The i4 Interface Module connects up to 12 detectors to a + wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones:a smoke zone,a CO zone and an control panels optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectors to the panel Installation ease:The i4 Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection. It • Initiates the EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings s kRvi LISTED SHI 1653:0228 i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire), 10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V In),26mA(24V In); 4-Wire:52mA'(max.),37mA'(12V In),22mA'(24V In) Alarm Current2: 2-Wire: 181 mA(max.), 121 mA(12V In),64mA(24V In); 4-Wire:78mA'(max.),57mA'(12V In),34mA'(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA I@ 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04 Depth: 1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20—70°C(-4—158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(P 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) *Th_ SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SEw SO� for current product information,including the latest version of this data sheet. ,vJ www.systemsensor.com CODS30302•11/13 INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM 0, w 00 .4 SENSOR® Series Interface Module 3825 Ohio Avenue,St.Charles,Illinois 60174 COSMOD2W and COSMOD4W 1-800-SENSOR2,FAX:630-377-6583 *For use with COSMO-2W and COSMO-4W detectors www.systemsensor.com SPECIFICATIONS Electrical Specifications Power Supply Voltage: Resettable power;2-Wire:Min.8.5 Volts DC(Power limited);Max.35 Volts DC(Power limited); 4-Wire:Min.10 Volts DC(Power limited);Max.35Volts DC(Power limited) Device Power-up Time: 200 milliseconds Max.Standby Current: 2-Wire:62mA;4-Wire:52mA(Does not include current draw from attached detectors or EOL relay) Max.Alarm Current: 2-Wire: 174mA;4-Wire:75mA(Does not include reverse polarity current draw from attached detectors) Nom.Standby Current: 2-Wire:45mA@12V,27mA@24V;4-Wire:36mA@12V,21mA@24V (Does not include current draw from attached detectors or EOL relay) Alarm Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Maintenance Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Max.IDC Loop Wiring Resistance: 2-Wire:50 Ohms;4-Wire:300 Ohms Trigger Inputs: Min.On Voltage: 1.5V;Max.On Voltage=Vin Aux Power Out: Same Voltage as Input Power(Unregulated,limited to 250mA) Min.Reset Time: 300 milliseconds Initial Communication Cycle: 6 minutes EZ Walk Test Availability: 6 minutes after power up or panel reset Physical Specifications Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 5-95% RH Storage Temperature Range: -20-70°C(-4-158°F) Height: 6.04 inches Width: 6.04 inches Depth: 1.16 inches Shipping Weight: 0.6 lbs Wire Gauge Acceptance: Min:22 AWG;Max: 14 AWG 2-wire Compatibility Requirements Min.Loop Voltage: 12.9 Volts DC Max.Loop Voltage: 14.5 Volts DC Max.Loop Resistance: 50 Ohms Max.Loop Ripple: 240 mVpp Max.Loading Capacitance: 0.01 mF Max.Alarm Current: 46 mA Max.Reset Voltage: 0.30 Volts DC Alarm Delay: n/a Min.Alarm Reset Time: 0.3 seconds Max.Normal Load Current: 2.4 mA Zone Type: Standard EOL Device: 3.9k Ohms(+-5%) Loop Style: B and D Compatibility Zone Identifier: A Detector Zone Identifier: A Max.Detectors Per Zone: (12)2-wire i4 series model#COSMO-2W and/or i3 series model#2WTA-B detectors BEFORE INSTALLATION The i4 COSMOD2W, 2-wire interface module, offers additional functionality This information is included as a quick reference installation guide. Refer to including: the control panel installation manual for detailed system information. If the module will be installed in an existing operational system,inform the operator • Ability to query for a "need for maintenance" condition from 2-wire i4 and local authority that the system will be temporarily out of service.Discon- series model COSMO-2W and i3 series model 2WTA-B smoke detectors nect power to the control panel before installing the module. • One relay is available to indicate a multitude of maintenance conditions Notice: This manual should be left with the owner/user of this equipment. at the control panel This product is intended for use in ordinary indoor locations. • All conditions are displayed at the module and at the detector GENERAL DESCRIPTION The i4 series module is designed to interface between compatible i4 series • EZ Walk test mode allows the installer to easily verify that all detectors combination CO/smoke detectors (Model COSMO-2W and COSMO-4W) and on a loop are operational compatible security/fire panels. It can also be used to retrofit compatible i4 • Allows 2-wire smoke detectors to be used on any compatible 4-wire series detectors into an existing loop of i3 smoke detector models 2WTA-B or control panel and provides Style D wiring on the detector loop 4WTA-B,without adding wires.The module interprets signals and translates FEATURES them into a separate smoke zone and a separate CO zone, each with alarm • Compatible with System Sensor i4 series combination CO/smoke detectors and trouble signals.When signaled by the panel,a module will synchronize and System Sensor i3 Series smoke detectors models 2WTA-B or 4WTA B. connected detector sounders in either Temporal 3 or Temporal 4 pattern.Local status indication is provided by 4 LED's and a 3 position DIP switch enables • Allows up to 12 compatible devices including the i4 series combination user configuration. CO/smoke detector to be integrated with a panel SS-500-004 1 156-3871-001 • Allows sounder activation of all detectors on loop in either Temporal 3 A CO alarm is self-clearing.Once a CO alarm has been signaled,the blue LED or Temporal 4 pattern will illuminate. Once the initiating device ceases to signal the CO event,the VISIBLE ANNUNCIATON blue LED will turn off. If a CO alarm is signaled, and not cleared,prior to a The i4 series interface module has four visible LED's:The green LED is a su smoke alarm condition, the module will keep both the blue and red LED's pervisory LED;it blinks during power on,reset,and during normal operation. illuminated.If a smoke alarm is signaled first,the module will not be able to The yellow LED is used to indicate a loop wiring fault and will blink when it receive notification of a CO alarm condition and will not be able to report it is in EZ Walk test mode.The red LED signals smoke events;it blinks during to the panel. smoke maintenance events and lights constantly during smoke alarm events. MAINTENANCE The blue LED signals CO events;it blinks during CO trouble or CO end-of-life, This condition means one or more detectors on the loop have a smoke main- and lights constantly during CO alarm. tenance issue.See"Smoke Maintenance Inquiry"section for further details. FIGURE 1:MODULE FRONT VIEW FREEZE TROUBLE \ This condition means one or more detectors on the loop are measuring the ambient temperature is near the freezing point.See"Freeze Trouble Inquiry" O section for further details. CO TROUBLE Green LED ► p .,,,ca,.,,,tecomax The module can be notified of a detector with a CO trouble condition.All CO Yellow LED ► p r wm Xi .x100F trouble conditions will be reported on the CO zone and displayed with a blink- Red LED ► ©"""Q, '•""""' ing blue LED. The module is not able to determine the number of detectors °X'"101¢"`""' that have a CO trouble condition or which trouble condition exists. Blue LED O.Q X1XXt23 EZ Walk Test Switch MIBeroXFZwAutlsT INSTALLATION (2-wire only) ► CR � rtDITICIDOUBLE MOUNTING 4JKIlANISTA1W' I O CAUTION The module can be mounted to a 4-"/16 inch back box or inside a listed,dedi- DEENmGI UNIT enclosure.When mounting inside an enclosure with pre-stamped holes, PRIOR TO SERVIGNB it may be easier to align the bottom screw hole first.It is not necessary to use the module cover when mounting inside an enclosure. S0331-00 TABLE 1:OPERATION MODES FIGURE 2:MOUNTING OPERATION GREEN YELLOW HOLE FOR MOUNTING TO VISTA ENCLOSURE MODE LED LED RED LED BLUE LED (No.6x3/4 Type AB) Normal(standby) Blink 5 Sec. OFF OFF OFF e' No power/ 11 16; CO Ilq OFF OFF OFF OFF Non-operational \I i� aaa o v Loop wiring fault Blink 5 Sec. ON OFF OFF � --- � I � O EZ Walk Test Mode Blink 5 Sec. Blink 5 Sec. OFF OFF O [ � (2-wire only) iI A mi Alarm Smoke Blink 5 Sec. OFF ON OFF al O i am Alarm CO Blink 5 Sec. OFF OFF ON f O iI Alarm Smoke&CO Blink 5 Sec. OFF ON ON 611 I I- © I�N1 i u� Maintenance Blink 5 Sec. OFF Blink 5 Sec. OFF � (2-wire only) 8 NC' 0 Freeze Trouble(2- Blink 5 Sec. OFF Blink 10 Sec. OFF 1 wire only) CO Trouble Blink 5 Sec. OFF OFF Blink 5 Sec. SLOTS FOR MOUNTING SLOT FOR MOUNTING TO VISTA ENCLOSURE TO 4-11/16 JUNCTION BOX 0331-00 NORMAL(STANDBY) (No.6x5/16Type AB or Type F) The module is powered and detectors on the loop are operating normally. WIRING GUIDELINES NO POWER/NON-OPERATIONAL All wiring must be installed in compliance with the NFPA 70 standards,Na- Power is not applied to the module or communication between the module tional Electrical Code, applicable state and local codes, and any special re- and the detectors on the loop is unsuccessful. quirements at the local Authority Having Jurisdiction(AHJ). LOOP WIRING FAULT The screw terminals in the mounting base will accept 14-22 gauge wire.Wire If an open circuit occurs on the loop,the module will indicate the condition connections are made by stripping approximately 1/a" of insulation from the by illuminating the yellow LED.2-wire units will then power the style-D ter- end of the feed wire,inserting it into the proper base terminal,and tightening minals.When the wiring issue on the loop has been resolved,the module will the screw to secure the wire in place. Do not put wires more than 2 gauge turn the yellow LED off. apart under the same clamping plate. EZ WALK TEST MODE Note: The module must be installed in the same room and within 20 feet of This indicates the module and detectors are in EZ Walk Test Mode.See"EZ Walk the panel and enclosed within conduit or equivalently protected against me- Test"section for instructions on how to initiate and perform the EZ Walk test. chanical injury. ALARM SMOKE/ALARM CO/ALARM SMOKE&CO A smoke alarm will be indicated by the red LED.A CO alarm will be indicated AWARNING by the blue LED. Remove power from alarm control unit or initiating device circuits before in- A smoke alarm is not self-restoring. Once a smoke alarm has been signaled, stalling detectors. the red LED will illuminate until the module is reset by removal of power. Note:On some panels,resetting a smoke alarm may require additional steps at the keypad to clear the trouble conditions on CO and smoke mainte- nance zones due to power loss to the module. SS-500-004 2 156-3871-001 FIGURE 3:COSMOD2W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED Note:See Table 3 for dip (EXCEPT TRIGGERS)AND MUST switch configurations SMOKE 0 BE POWER LI MITER AUXPOWER O O (resettable) 1 C °° i�� Opp9����� 1®10 � [_I r� �5 �o SMOKE O �r_1 © , 1 L1 Panel �/ ®� 0 [ 71 Resistors A ZONE O [:.I F o �i ® 14)J �o ' i 3.9k �� r� EI )I RESISTOR I I (IB 1- O LSF I I ea7 /O o I (suppled Ic0 I +� , ® with module) CO Q I + IQ ® 'ZONE 0 I (.,;, /-6`—'4, --.-) n B lI I \$ ' __,. /.0\ r/ I MAI NT. O COSMOD2W I LOOP STYLED WIRING I ZONE O EOL I COSMO 2W BELL [ 5f. Resistor , OR F —I SMOKE I TRIGGER OUT43 50329-00 CO TRIGGER , OUT FIGURE 4:COSMOD4W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED SMOKE Q (EXCEPT TRIGGERS)AND MUST BE POWER LIMITED POWER O (resettable) Q °o Ela I vol) p �Panel oil ET SMOKE , �� EOL _ P oQ o * oo ZONE oflel © - 111 N 3.9k CO 0 _ __�I,VI © 1 — _ — /��� ���; RESISTOR f "I— �� �," (supplied ZONE Q e e with module) COSMOD4W COSMO-4W I , BELL 10, I OR : I SMOKELI J I 50330-00 I TRIGGER OUT I CO TRIGGER OUT L a / + `\ FIGURE 5:MODULE TERMINALS l OO 0 %In LJ \POWER IN + Na P ®I , •SMOKE ZONE EOL RESISTOR POWER IN— , a © j (VALUE DEFINED BY PANEL) SMOKE ALARM CONTACT © ICI, CO ZONE EOL RESISTOR t3•-,l ISI (VALUE DEFINED BY PANEL) MAINTENANCE TROUBLE RELAY CONTACT O O- 1 IDC+ (COSMOD2W ONLY) �+� II IDC— CO ALARM CONTACT I 14I O Sle — STYLE D+(4-WIRE DETECTOR POWER+) vI © IC I� STYLE D—(4-WIRE DETECTOR POWER—) CO TRIGGER I SMOKE TRIGGER/BELL IN i O � � O ~ ® O 50334-00 SS-500-004 3 I56-3871-001 WIRING DIAGRAMS FREEZE TROUBLE INQUIRY Install module wiring in accordance with appropriate wiring diagrams. The module sends a freeze trouble inquiry to the detectors every four hours. (Figure 3 and Figure 4) (Compatible i3 Series 2-wire smoke detectors only) If a response indicating a The module relays have a maximum ON resistance of 25 ohms. This resis- freeze problem is received,the red LED on the module will blink once every tance plus the wiring resistance to the panel must be less than the maximum 10 seconds and a smoke maintenance condition will be indicated to the panel. zone wiring resistance stated in the panel manual. TESTING INPUT TRIGGERS/SOUNDER ACTIVATION Modules must be tested after installation and following periodic maintenance. Many panels can be programmed with triggers which are auxiliary relays that Testing should be performed at least once per year. activate upon an alarm condition. Two inputs are used to signal the module NOTE:Before testing,notify the proper authorities that the system will be tem- to activate device sounders.The first is configurable by DIP switch to one of porarily out of service. Disable the zone or system to prevent any unwanted two modes;bell in or smoke trigger.When in the bell mode,the module will alarms. follow a valid coded signal from a Bell Out/NAC circuit consisting of high to EZ WALK TEST low,then low to high for less than 1.9 seconds each. In smoke trigger mode, The communication loop between the 2-wire modules and detectors can be while the input is held high,the module will synchronize the detectors in a manually tested by putting the module and detectors into EZ Walk test mode. Temporal 3 pattern. This feature is for use with System Sensor detectors(i4 series model COSMO-2W The second input is for a CO trigger;the CO trigger input allows a single mod- and i3 series model 2WTA-B)installed with the model COSMOD2W module. ule to have CO silence/hush capability and allows multiple module installa- The EZ Walk loop test verifies the initiating loop wiring and provides visual tions to have all sounders activated in Temporal 4 in the event of a CO alarm. status indication at each detector: While the CO trigger is held high,the module will synchronize the detectors in a Temporal 4 pattern.After 30 minutes in Temporal 4 alarm,the time period 1. Ensure proper wiring and power is applied. Wait approximately 5 min- between the Temporal 4 pulse will change from 5 seconds to 60 seconds. utes from power-up before performing the EZ Walk test.The green LED on the module must be blinking indicating the module is in ready/ Note: CO trigger may not be used with UL 864 panels.All detectors will sound standby mode to start the EZ Walk mode. with no triggers connected,however,hush capability is not enabled. TABLE 2:DIP SWITCH CONFIGURATIONS 2. Locate the EZ Walk recessed test switch located behind the module cover (See Figure 1).Depress the test switch with a small screwdriver. The yel- DIP SWITCH#1 DIP SWITCH#2 DIP SWITCH#3 low LED will blink showing that the module and detectors are in EZ Walk Smoke Maint on mode for 5 minutes. ON Bell In Smoke Trouble and Unused 3. Observe the LEDs at each detector to make sure the green LED is double (DEFAULT) Form-B Maint Relay blinking every 5 seconds as listed in Table 3. (COSMOD2W only) 4. At the end of the five minute period,the module will terminate EZ Walk Smoke Maint on and the yellow LED will stop blinking. The EZ Walk test period can be Form-B Smoke main- extended bypressingthe test switch multiple times.Each press will add OFF Smoke Trigger Unused P tenance Relay only 5 minutes of additional time. (COSMOD2W only) If a module or detector fails the test, its wiring should be checked. If the POWER UP AND COMMUNICATIONS module still fails,it should be replaced.Notify the proper authorities when all COMMUNICATIONS CHECK(2-WIRE ONLY) testing has been completed. Upon power up,the module will send a request for communication check.All compatible detectors on the loop that understand the communication protocol NOTE:The EZ Walk loop test should not be used in lieu of functional testing will respond.If all detectors respond correctly,the green LED will blink once (alarm,trouble and other functional tests)of the system. every 5 seconds. If the module does not get a response, it will turn off the TABLE 3:EZ WALK TEST DETECTOR MODES green LED and continue to try every 2 minutes until a response is received. DETECTOR DETECTOR SMOKE MAINTENANCE INQUIRY GREEN LED RED LED The module sends a smoke maintenance inquiry to the detectors every 24 PROPER OPERATION Double Blink 5 Seconds OFF hours. (Compatible 2-wire detectors only) If a response indicating a mainte- nance problem is received,the red LED on the module will blink once every 5 OUT OF SENSITIVIY OFF Double Blink 5 Seconds seconds and a smoke maintenance condition will be indicated to the panel.It is likely that the detector needs to be cleaned or replaced,refer to the detector FREEZE CONDITION OFF Double Blink 10 Seconds instruction manual for maintenance instructions. FCC STATEMENT This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause undesired operation. NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installa- tion.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed product to be free from defects in materials and # ,3825 Ohio Avenue,St.Charles,IL 60174.Please include a note describing workmanship under normal use and service for a period of three years from date of the malfunction and suspected cause of failure.The Company shall not be obligated to manufacture.System Sensor makes no other express warranty for the enclosed product. replace units which are found to be defective because of damage, unreasonable use, No agent,representative,dealer,or employee of the Company has the authority to in- modifications,or alterations occurring after the date of manufacture.In no case shall the crease or alter the obligations or limitations of this Warranty.The Company's obligation Company be liable for any consequential or incidental damages for breach of this or any of this Warranty shall be limited to the replacement of any part of the product which other Warranty,expressed or implied whatsoever,even if the loss or damage is caused by is found to be defective in materials or workmanship under normal use and service the Company's negligence or fault.Some states do not allow the exclusion or limitation of during the three year period commencing with the date of manufacture.After phoning incidental or consequential damages,so the above limitation or exclusion may not apply System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return Authorization to you.This Warranty gives you specific legal rights,and you may also have other rights number,send defective units postage prepaid to:System Sensor,Returns Department,RA which vary from state to state. SS-500-004 4 I56-3871-001 ©2012 System Sensor i4 Series Combination Carbon Monoxide(CO)/Photoelectric Smoke Detector it4 COSMO 4W (4 wire) Wiring Diagram PANEL (4-wi re) SMOKE 0- i4 MODULE* i4 DETECTOR POWER O r N _ (resettable) , D- 923 �I lIi 0 —®llc___ l Panel Eo SMOKE EOL ol RELAV ZONE I SII l Resistors / \ 4wlR: \ . FOLK-, 0 as I { cra -011 6 �l O El III7H 3.9k CO - (�I © Imo, 9/ RESISTOR - - 0 r - - -+(• ! [®JI - , ` I (supplied I `ZONE 0 with module) 0 71 1 `� � � I COSMOD4W � COSMO-4W I BELL 0- -i I OR I I I i4 MODULE TERMINALS F -I J SMOKE TRIGGER OUT //i 144,1_ J I I � � O1:11 QI POWER IN+ MiIG}Il1 1�IM� CO ■-II«'�7 �"�� SMOKE ZONE EOL RESISTOR TRIGGER r J POWER IN- 151 © I-. �-■ (VALUE DEFINED BY PANEL) ■�Il� I-■ CO ZONE EOL RESISTOR QST** J SMOKE ALARM CONTACT i ■ (VALUE DEFINED BY PANEL) MAINTENANCE TROUBLE RELAY CONTACT i O IDC+ ■-III-■DIP SWITCH CONFIGURATIONS (COSMOD2W ONLY) iIDC■ Wili }.-I STYLE D/CLASS A+(4-WIRE DETECTOR POWER+) DIP SWITCH#1 DIP SWITCH#2 DIP SWITCH#3 CO ALARM CONTACT ■ iji1 ■ l OSTYLED/CLASSA–(4-WIRE DETECTOR POWER–) ONSmoke Maint on Smoke Trouble CO TRIGGER lii] lSMOKE TRIGGER/BELL IN (DEFAULT) Bell In and Form-B Maint Relay Unused -' (COSMOD2W only) I 8Ick— O 7c9 171 I Smoke Maint on Form-B OFF Smoke Trigger Smoke maintenance Relay only Unused ° � 0 `� J (COSMOD2W only) COSMOD4W �� SYSTEM Module is also compatible withSmoke Detector **Triggers are optional and can bee used used to interconnect multiple modules with a bell output or positive voltage from the panel. �� SENSOR' Please consult panel manufacturer for programming outputs advanced ideas.advanced solutions° ***Up to 12 detectors per module;models COSMO-4W or 4WTA-B only. Module interconnects sounders of both devices(RSS-MOD not needed). ©lois System sensor.coFL8lo2•7/13 SYSTEM �$ SENSOR (011111 . -\\ 5600 Series Mechanical • . . Heat Detectors \r--- 4 System Sensor's 5600 series mechanical heat detectors i offer a low-cost means for property protection against fire,and for non-life-safety installations where smoke �I detectors are inappropriate. ' Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations: configurations to accommodate a broad range of applications.Both -Single and dual circuit models single-and dual-circuit models are available for low-and high- -Fixed temp and combination fixed temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to-use terminal screws Installation flexibility.To satisfy a variety of installation needs, •Abroad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back -Single gang boxes.And these models accommodate four-square back boxes, -3.5"and 4"Octagonal when used with a square to round plaster ring.The reversible -4"square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate-of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings 13 ® MEA LISTED APPROVED approved S2101 3016008 199-03-6 7270-1209227 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single-circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature,approximately 15°F(8.3°C)per minute.The detector shall include a reversible mounting bracket for mounting to 31/-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method.The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable,to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°C) Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(4.3cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz.(170 grams) Rate-of-Rise Threshold 15°F(8.3°C)rise per minute(models 5601P,5602,5621,and 5622 only) Mounting 31/-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/0.3A 250VDC/0.1 A Input Terminals 14-22 AWG aonik x.1aowxi— '''''s0 11 ----'—''' o o 0 0 ) , 1,.. „,„.,,,,,,‘ ., /.///.. .\\,„ I , . . . . ,,,,,__ _ ____ ---- Iiia Y 3 fit taiklY i 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information Identification Method Temperature Model Circuit on Exterior Rating Activation UL Protected Spacing-10 Foot Ceiling* 5601 P Single None 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5603 Single Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(15.24m x 15.2m) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. *Th_ SYSTEM m2006 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Usit systemsensoccom for SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0351-002.11/06•#1676 Si GE I nterl ogi x Product Information www.C Inteiogix.com PinPoint Addressable Fbint ID Systems Overvi ew The RnFbi nt addressable solutions bring together NetwcrX NX-8E fuuxionditywith the reliability of GE Interlogix sensors. 7, 4110. Supporting up to 192 devices on a single two-wire loop up to two niles,the RnFbint pant IDsolution can be installed fast in new construction or retrofit applications. 4 L Components 71r NetworX NX-8E I I/ Part#NX-8E l I I I IIIR nPoi nt Interface Card Part#NX-2192E AP SeriesEl Standard Features Motion Sensor o Si ngl e two-w i re loop up to two miles means fast and easy Part#AP750-ID installation for new construction or retrofit applications o Addressable sensors indicates exact l ocati on of alarm or trouble event ShatterPro® o Supports up to 192 devices • Gassbreo Advanced digital communication from the sensors to Part#5845-1D the panel o GE Interlogix—a name you know and trust o Supports 3 a ass B loops CISingle Input Device Part#S1-1D ZI4Input 4 Output Device Part#4144ID PinPoint Addressable Fbi rit ID Systerrs AP750-I D Addressable PI R Description Specifi cati ons An addressable RRfor use with the NX 2192ERrpant ID Bus Housing Material Rare retardant ABS Interface Operating voltage 8 to 27V(as supplied by N)F2192E) Current draw 250µA typical avg.3mAwith LED momantarily on Features Transmit condition Alam,tamper Detection range 50 ft(15.2m) AcIaptiveSncglefooessing-3Dsignal processing with gliding Mounting height 6 to 10 ft(1.8 to 3m) focus nirror optics analyzes sim,speed,shape and adaptive Number of curtains 7 alarm threshold. Operating temperature 32°to 131°F(0°to 55°C) Friel ati ve humidity 10%to 90%nonoor densi ng Rovi des far separate curtain average patterns with 50' Maxi mum I i ne length 10,000 ft(31mi) (15.2 m)range. Di mensi ons Flatcomer wall or coer mounting height up to 10'(3m). D Width 2. (74mm) Depth 2.2(56mm) Ships with two plastic inserts,each covering half the coverage Height 5.1'(129mm) pattern for more flexible mounting options(center curtain Listings (1639,Rx always alive). Coverage Patterns 50' 15.2m �\ I I ��-� II I I 3.0m I 45° Left ' 1 7 44m 45° F4 ght 5845-I D Addressable Shatterpro®GI assbreak Description Spec ifi cat ons An addressable ShatterRo®ll gl assbreak for use with the Housing material Rare retardant ABS NX-2192E RnRbi nt ID as Interface. Operati ng voltage 8 to 27V(as supplied by NX 2192) Current draw 250µAtypical avg.3m4 with LID=mentally on Features Microphone 0mi-directional eledret Operating temperature 14°to 120°F(10°to 50°C) ShatterR-o's Pattern Fieoognition Technology'"for superior Relative humidity 10%to 90%nonoondensi ng detection and fa se alarm irrrrunity. Maxi mum I i ne length 10,000 ft(3lom) Roteds all glass types up to a standard thickness of 1/4" Di rrrensi ons (6.4 m)including plate,wired,tempered and land nated glass. Width 3.13 (80rrm) mm) Depth 1.7'(4311111) Senses through light blinds and unlined drapes.Suitable for use Height 4.2(108r m n) in occupied areas cn the perimeter loop. Listings MC i v Wall mount 0'(6max ) m 20'(6m)/ � max. Ceiling mount PinPoint Addressable Fbi nt ID Systems SI-ID Single Input Device Description Specifications Anadci-essablesingle input interface toconnect asingle I-busing material Hare retardant ABS non-addressable device to the NX-2l92EPnRjuit ID Cperati ng voltage 8 to 27V(as supplied by NX-2192E) bus interface. Signaling voltage 4 to 9V Current draw 250µA operating temperature 32°to 131°F(0°to 55°D Features Fel ati ve humidity 10%to 90%noncondensi ng Maxi mum I i ne length 10,000 ft(3km) Supports a single non-addressable device. Dimensions Width 3.3(84rrm) Uilixs advanced digital data corrrrunications protocol that Depth 13(331rrn) ensures the integrity of the data corrrruni cati on. Height 2.8'(71rrm) Li stings LL 365,U_609,U_985, U_1023,U_1610,FCC Input Loop Resistance Reported to panel To single (47k ECL included) non-addressable From PinPoint device,such as a loop O magnetic contact >1M— Cpen 47l % Single B1 J 941 % Double B1 >20❑ Short 4140-ID Four Input Four Output Device Description Specifi cati ons An addrescable 4 input and 4 unsupervised output interface Housing material Flame retardant ABS that al Iays you to conned up to 4 nonradd-essable devices Cperati ng voltage 12 to 30VDC to the NX 2192E RnRbi nt ID Bus Interface. Signal i ng voltage 4 to 9V Current draw 100µA(bus loading) Features Output current 500m4 rradrrum eadi Cperati ng temperature 32°to 131°F(0°to 55°C) Supports four inputs andfair unsupervised outputs FelativeHumidity 10%to 90%nonoondensing (horns,bells,sirens,etc.). Maxi mum line length 10,000 ft(3km) Uilims advanced digital data com7unications protocol that Di idth ns ensures the integrity of the data cor .nication. D pth 6.8'(173rrm) m� Depth 2.0'(51n-m) Height 4.8'(122rrm) Listings LL 365,LL 609,LL 985,LL 1023,111610,FCC To unsupervised Addressable 1 outputs,such as Inputs 0 0 0 horns and sirens Input Loop Resistance Reported to panel (47k ECL i ncl uded) >1M Cpen o 0 oJ 47k±5% Single ECL 9.4k % Double B1 >20H Short PinPoint Addressable Fbirttt IDSystems NX2192E Description Specifi cati ons Rint ID as Interface Card. Current Draw 170 m4 standby maximum C perati ng temperature 32°to 122°F(0°to 50°G) Shipping Weight 0.5 lb. Features D mensi ons Width 2'(51rm) Attaches to the NX-8Eccntrd pard. Depth 1.25(32nm) as interface that supports up to 192 addraable devices on Height g(229r m) a two-rile loop. Supports three dasc B loops. Ordering Information Model Description Listing Approvals NX-8E NetwcrXNX8Econtrd paid — ll NX-2192E RnFbi nt interface card — LL AP750-ID Ge interlogx RR White UL 5845-ID Cainterlogixgassbreak White RCC SI ID Engle input device White LL 414GID 4 input 4 output device White 11 CInterlogix www.CEIrrteriagxczm 12345SWLevetcnDive 22ti6SsaaxlStreet Nath Tualatin,CR97062 North St.Pat/,MN 55109 Foie:503-692-4052 Rr ie:651-777-2693 54&Canada: LISA&Canada:800-777-5484 Technical Service:800-648-7424 Technical Service:893-777-2624 Fadzadc 800-483-2455 ©2003CEInterlojxarnke!in a Can is atraderrerkcfCfInterlogxPlltraderrni¢are properties cftheir oars. M-4301-xO004(0103