HomeMy WebLinkAboutA15-0097_FA000_1447101360.pdf 41° Cir I/4 4. X LEGEND . Vail Fire&Emergency Services SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 11/09/15 FACP Caddx (NetworkX) NX-8E Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox Combination Smoke and Oco CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box ® System Sensor 5601P Heat Detector w/SI-ID Addressable module 4" square box © Cosmo Interface Module COSMOD4W z 0 III Knox Box I- E U w 0 Z 0 5w w H- Q 0 ZONE Type of Device Level Description 001 HEAT DETECTOR B GARAGE 0 z 002 HEAT DETECTOR B GARAGE D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 003 SMOKE DETECTOR 1 1ST FLOOR SMOKE DETECTOR 004 CO DETECTOR 1 1ST FLOOR CARBON MONOXIDE X = 2-WIRE DATA, 2-#1 6AWG � w 005 SMOKE DETECTOR 2 2ND FLOOR SMOKE DETECTOR O z 006 CO DETECTOR 2 2ND FLOOR CARBON MONOXIDE N = 2-WIRE SOUNDER CIRCUIT, 2-#1 8AWG °' • Z = 2-WIRE DATA CIRCUIT, 2-#16AWG o Q EOL EOL o 0 KP = KEYPAD CIRCUITING, 4-#18AWG 2 o �co co CO I O U Battery Calculations RISER NOTES: / / �- 0 (f) Caddx NX-8E 1. REFER TO PANEL INSTALLATION MANUAL FOR D D 6 _1 c w Standby MORE INFORMATION. ��. ,___ i o z Number of Current Total Current 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS _c Q Device Type Devices (Amps) (Amps) MANUFACTURERS SPECIFICATIONS. NX-8E CONTROL PANEL L,N c L,N c i �l N Main FACP CPU 1 X 0.075 = 0.075 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) Li NX-14E LCD Keypad 1 ' X 0.075 = 0.075 PRIOR TO INSTALLATION. WIRING DIAGRAM IS Cr) - COSMOD4W Module 2 ' X 0.052 = 0.104 INCLUDED SUBMITTAL BOOKS. 4193 Z Q ® ' 11111111 i4 Smoke/CO Detector 7 X 0.0005 = 0.0035 SI-ID Module 2 X 0.0025 = 0.005 1 20VAC DEDICATED POWER (1) . 1e� SUM COLUMN FOR STANDBY LOAD 0.2625 = AMPS Alarm Load Number of Current Total Current Device Type Devices (Amps) (Amps) TELEPHONE LINE 0 Main FACP CPU 1 ' X 0.14 = 0.14 - NX-14E LCD Keypad 1 ' X 0.11 = 0.11 4- COSMOD4W COSMOD4W Module 2 X 0.075 = 0.15 0 i4 Smoke/CO Detector 7 X 0.04 = 0.28 RISER D AG RA M DAOUTPOT KP KEYPAD L. SI-ID Module 2 X 0.0025 = 0.005 W } SUM COLUMN FOR ALARM LOAD 0.685 = AMPS W ro Standby Load Required Standby Time in Hours f o O Current (Amps) 00 0.2625 X 24 = 6.30 d Alarm Load Required Alarm Time in Hours ( 0 Current (Amps) (15 MINUTES) 0 GENERAL NOTES: N ct 0.685 X 0.25 = 0.17 N- O Add Standby and Alarm Load for Required 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH 0 Ampere Hour Battery 6.47 MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. Cl ® ,< <' Multiply by the Derating Factor of 1.2 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR O o Total Ampere Hours Required = 7.77 m (U FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, - Minimurn Batteries Provided: sAH PROGRAMMING AND DEVICE OPERATION. CL li_ approved for , . install , VF&ES ;� r is . . :1„00...z....3.7. 3.3,... :ii_, '. W 0_ C PROJECT INFORMATION : z 5123 BLAC < BEAR LANE s SEQUENCE OF Q w w (n OPERATIONS: N J Z Z VAIL COLORADO w z0 >- z oz N0 Q FIRE ALARIV SYSTEM w Q�/ J C� O Li j 1— (!) Z I..1_ E `SI- > 1- J1- cKQ mo Z D "' w "' m `� o o z AHJ: VAIL FIRE & EMERGENCY SERVICES Q 0 g. Q Z N Z 1- Z w E ~ APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC J w COw v) o v, 0 v, o o1- 3 1 OCCUPANCY: GROUP R w O C/) 0 DEVICE I z Q z o z o w z USE: SINGLE FAMILY HOME W p ›- DEVICE a Q Q < U) Q ct 0 ix 0 ce 0 0 m 0 D FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM WILL INCLUDE A m NEW FACP. COMBINATION SMOKE/CO DETECTORS WILL BE INSTALLED IN 0 SMOKE DETECTOR X X X EACH SLEEPING ROOM AND LIVING AREA. HEAT DETECTORS WILL BE J Q 0 INSTALLED IN THE GARAGE. DETECTORS HAVE INTEGRAL SOUNDERS. THIS < 0 J z HEAT DETECTOR X X X SYSTEM IS NOT FULLY ADDRESSABLE. RATHER, TWO ZONES OF CO 0 Q 0 CO/SMOKE DETECTION ARE PROVIDED, ONE FOR EACH FLOOR. A ZONE .) J w CO CARBON MONOXIDE DETECTOR X X X LIST INDICATING HOW DEVICES WILL REPORT IS INCLUDED ON THIS SHEET. CV Q ( w 10 > U 0 POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X FIRE PROTECTION ENGINEER: SHEET DESCRIPTION: DEBORAH SHANER, P.E., SHANER LIFE SAFETY FIRE ALARM PLAN PO BOX 1073, FRISCO, CO 80443 PHONE: 970-409-9082 DRAWN BY: DATE: FAX: 970-797- 1898 DLS 10/20/15 SHEET#: FA-000