HomeMy WebLinkAboutA15-0102_FA000S_1447969200.pdf LEGEND : . SYMBOL DEVICE MANUFACTURER/PART# MOUNTING FACP Honeywell Vista-128BPT € .. CB7 Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox ; ,;:i:1:4:: : Vail Fire 1e&Emergency Services KP (.1:7?., 352331 P•10 • LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox ��r i t; �?v�" � �\\. 0 Smoke Detector Honeywell 5193SD 4" square box �. s ,� — ® System Sensor 5601P z Heat Detector w/4193SN Addressable module 4" square box I- a E U Sounder System Sensor MHW Single gang box w a z O Co Carbon Monoxide Detector Honeywell 580000 Single gang box i-n 5w Lt KB Knox Box Approved a0 Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox ' ' for install . LuI- a GENERAL NOTES: 3 #16 PAIR, 1 DATA, 1 SOUNDER, 1 POWER e 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN z ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. EOLR p El p p changes 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION (8) (8) (11) (1) Honeywell U REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, VISTA 128 Z ni amay be PROGRAMMING AND DEVICE OPERATION. U, O Ct • I— KP F- required DIALER U w DEDICATED 120V J J 0 N pTELE LINES w er SECONDARY RESIDENCE J 00 co co . . SYSTEM ONE- LINE DIAGRAM = o ° COn I I O n s NOTE 1. NO T-TAPPING PERMITTED ON ANY CIRCUIT NOTE 2. ALL WIRING TO BE 18AWG FPL. > . Z CD CO 0: Qrn • SEQUENCE OF J a Z Q w —OPERATIONS: x 0 0z wz -0z o J 00 00 00 z %, m (n (,., (7) Q u) i< ,1, Q o Oz N 1- > I— -II- 0 0 f N W Dv) co Z E o 21- < E m E I-E ix 1- m Li- MN � N � N � 0 0 0 �tii.� H I- I-DEVICE Q am z0 z0 z0 a0 a� I Uw go go go Io Io A,- DESCRIPTION < a � � � � � � � Q (n ai SMOKE DETECTOR X X X ■ ■ HEAT DETECTOR X X X CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X NOTE: THIS DUPLEX CONSISTS OF 6 LEVELS. THE LOWER (1ST) LEVEL SERVES AS THE GARAGE AND ENTRY FOR BOTH THE PRIMARY AND SECONDARY RESIDENCES. THE 2ND AND 3RD LEVELS SPRINKLER TAMPER SWITCH X X co ARE DEDICATED TO THE PRIMARY RESIDENCE AND THE 4TH, 5TH & 6TH LEVELS ARE THE CO SECONDARY RESIDENCE. THE UNITS HAVE BEEN SUBMITTED AS TWO SEPARATE PERMITS WITH TWO SEPARATE FIRE ALARM SYSTEMS. POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X I 0) Co SECONDARY RESIDENCE ZONE LIST ti SECONDARY RESIDENCE PROJECT I N FO R N ATI 0 \ : a, w DEVICE # DEVICE TYPE LEVEL DESCRIPTION Ademc❑ Vista 128 FACP FISHER RESIDENCE - SECONDARY _ 0_ n 001 MONITOR ' SPRINKLER WATERFLOW Standby 002 MONITOR 1 SPRINKLER TAMPER Number of Current Total Current 003 HEAT DETECTOR 1 GARAGE Device Type Devices i (Amps) (Amps) VA I L, COLORADO — w 004 SMOKE DETECTOR 1 MAIN ENTRY Main FACP CPU 1 X 0.032 = 0.032 z z 005 CO DETECTOR 1 MAIN ENTRY 4193SN Serial Interface 11 X 0.00015 = 0.00165 FIRE A LA R VI SYST E IVo// Q CL SMOKE DETECTOR 4 MASTER BEDROOM 5192SD Smoke Detectors 11 X 0.00084 = 0.00924 = 007 CO DETECTOR 4 MASTER BEDROOM Carbon Monoxide Detectors 8 X- 0.00025 = 0.002 AHJ: VAIL FIRE & EMERGENCY SERVICES I— C/) 008 SMOKE DETECTOR 4 FAMILY ROOM 6160 Keypad 1 X 0.04 0.04 ' APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC U 009 CO DETECTOR 4 FAMILY ROOM SUM COLUMN FOR STANDBY LOAD 0.08489 = AMPS OCCUPANCY: GROUP R w = 010 SMOKE DETECTOR 4 SOUTH BEDROOM w USE: DUPLEX 011 CO DETECTOR 4 NW BEDROOM Alarm Load Ct 012 SMOKE DETECTOR 4 NW BEDROOM Number of Current Total Current FIRE ALARM SYSTEM FOR SECONDARY RESIDENCE OF DUPLEX. SYSTEM J 0 013 SMOKE DETECTOR 5 FAMILY ROOM Device Type Devices (Amps) (Amps) INCLUDES NEW ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. D CO 014 CO DETECTOR5 FAMILY ROOM -' Main FACP CPU 1 X 0.032 = 0.032 w 015 SMOKE DETECTOR -5 STUDY - 4193SN Serial Interface 11 X 0.00015 = 0.00165 SMOKE DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS, STAIRWELL 0 016 CO DETECTOR 6 'WEST BEDROOM 51925D Smoke Detectors 11 X 0.0196 = 0.2156 LANDINGS AND AREAS OUTSIDE OF SLEEPING ROOMS. A HEAT DETECTOR 017 SMOKE DETECTOR 6 WEST BEDROOM Carbon Monoxide Detectors 8 X 0.00025 = 0.002 WILL BE INSTALLED IN THE GARAGE. SOUNDERS WILL BE PROVIDED IN Q Q 6160 Keypad 1 X 0.1 = 0.1 Ct 018 CO DETECTOR 6 TOP OF STAIRS SLEEPING ROOMS AND AS NEEDED TO ACHIEVE AUDIBILITY. A KNOX BOX 019 SMOKE DETECTOR 6 TOP OF STAIRS MHW Sounder 8 X 0.066 = 0.528 WILL BE MOUNTED ON THE OUTSIDE OF THE HOME. MONITORED CARBON O 020 SMOKE DETECTOR 6 EAST BEDROOM Outside Horn/Strobe 1 X 0.195 = 0.195 O 0 SUM COLUMN FOR ALARM LOAD 1.07425 = AMPS MONOXIDE DETECTORS ARE PROVIDED. J U 021 CO DETECTOR 5 GREAT ROOM Q w 022 SMOKE DETECTOR 5 GREAT ROOM Standby Load Required Standby Time in Hours J_ O z 023 Current (Amps) Q 0 O 024 0.08489 X 24 = 2.04 Jz 025 Alarm Load Required Alarm Time in Hours z (n 026 Current (Amps) (15 MINUTES) CDQ O W 027 1.07425 X 0.25 = 0.27, FIRE PROTECTION ENGINEER: > 0 0 028 Add Standby and Alarm Load for Required 029 Ampere Hour Battery 2.31 DEBORAH SHANER, P.E., SHANER LIFE SAFETY SHEET DESCRIPTION: 030 Multiply by the Derating Factor of 1.2 PO BOX 1073, FRISCO, CO 80443 FIRE ALARM PLAN THRU Total Ampere Hours Required = 2.77 PHONE: 970-409-9082 050 Batteries Provided: 4AH Minimum FAX: 970-797- 1898 DRAWN BY: DATE: DLS 11/3/15 SHEET#: SECONDARY RESIDENCE FA-0.00P