HomeMy WebLinkAboutA15-0055_A15-0055 Product Data_1434552480.pdf PRODUCT DATA SHEETS FIRE ALARM DETECTION SYSTEM Unit 8203 Remodel Four Seasons 1 Vail Road Vail, Colorado 1 John Bal!man Nicet Fire Alarm systems Level IV Certification #101808 Date: I SYSTEMS GROUP 800 E. 64th Avenue #17 Denver, CO 80229 Phone: (303) 298-7900 Fax: (303) 650-5667 t%'51-R6'S, Model# Description Cat.Sheet# SIGA-PS Photoelectric Smoke Detector 85001-0269 SIGA-AB4G Audible Sounder Base 85001-0581 6/16/2015 *'5rEIS RP 6/16/2015 EST Catalog ► Intelligent Initiating �ESTTM Life Safety & Communications Intelligent ,. Ph • otoelectric Smoke Detector SIGH-PS lsr' (E Application Notes Available \\ A _t Overview receiving circuit. The Signature Series Model SIGA-PS Intelligent Photoelectric Fast Stable Communication-On-board intelligence means less Smoke Detector gathers analog information from its smoke sens- information needs to be sent between the detector and the loop ing element and converts it into digital signals.The detector's controller. Other than regular supervisory polling response,the on-board microprocessor measures and analyzes these signals. It detector only needs to communicate with the loop controller when compares the information to historical readings and time patterns it has something new to report. to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. Standard Features The microprocessor in each detector provides four additional ben- • Integral microprocessor efits-Self-diagnostics and History Log,Automatic Device Map- ping, Stand-alone Operation and Fast, Stable Communication. • Non-volatile memory Self-diagnostics and History Log - Each Signature Series • Automatic mapping device detector constantly runs self-checks to provide important mainte- • Electronic addressing nance information.The results of the self-check are automatically updated and permanently stored in the detector's non-volatile • Environmental compensation memory • Intelligent detector Automatic Device Mapping-The loop controller learns where • Wide 0.67%to 3.77%/ft.sensitivity range each device's serial number address is installed relative to other • Twenty pre-alarm sensitivity values, set in 5%increments devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being • Identification of dirty or defective detectors reinstalled(after cleaning etc.)in a different location from where it • Automatic day/night sensitivity adjustment was originally. • Twin RED/GREEN status LEDs Stand-alone Operation-A decentralized alarm decision by the detector is guaranteed.On-board intelligence permits the detector • Standard, relay,fault isolator,and audible mounting bases to operate in stand-alone mode. If loop controller CPU communi- • Designed and manufactured to ISO 9001 standards cations fail for more than four seconds, all devices on that circuit go into stand-alone mode.The circuit acts like a conventional alarm Pagel of 4 DATA SHEL , 85001-0269 Not to be used for installation purposes. Issue 6 Installation Accessories Signature Series detectors mount to North American 1-gang All detector mounting bases have wiring terminals that are acces- boxes,3-1/2 inch or 4 inch octagon boxes, and to 4 inch square sible from the"room-side"after mounting the base to the electri- electrical boxes 1-1/2 inches(38 mm)deep.They mount to Euro- cal box.The bases mount to North American 1-gang boxes and pean BESA and 1-gang boxes with 60.3 mm fixing centers. to 31/2 inch or 4 inch octagon boxes, 11/2 inches(38 mm)deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers.The SIGA-SB4, SIGA-RB4, and SIGA-IB4 0.8 (20 mm) mount to North American 4 inch sq.electrical boxes in addition to the above boxes.They include the SIGA-TS4 Trim Skirt which is used to cover the"mounting ears"on the base.The SIGA-AB4G 2.0"(51 mm) mounts to a 4"sqare box only. � II U 4.4'(112 mm) Tamper-Resist Lever Arm �dL I.�i_� SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED -Break off to disable- ',� 410La� Audible Base Standard Base Isolator Base Relay Base Remote LED (Located on Base) 1.1 Standard Base SIGA-SB,SIGA-SB4-This is the basic mount- ing base for Edwards Signature Series detectors.The SIGA-LED Remote LED is supported by the Standard Base. Access Slot for Tamper-Resist Mechanism ; Relay Base SIGA-RB,SIGA-RB4-This base includes a relay. _� ��. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp(pilot duty)Q 30 Vdc.The relay's • O position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel(EST3 V2 only).The relay base does Testing & Maintenance not support the SIGA-LED Remote LED. Each detector automatically identifies when it is dirty or defective Audible Base SIGA-AB4G-This base is designed for use where and causes a"dirty detector"message.The detector's sensitiv localized or group alarm signaling is required.When the detector ity measurement can also be transmitted to the loop controller.A senses an alarm condition,the audible base emits a local alarm signal.The optional SIGA-CRR Polarity Reversal Relay can be used sensitivity report can be printed to satisfy NFPA sensitivity meas- for sounding to other audible bases on the same 24 Vdc circuit. urements which must be conducted at the end of the first year and every two years thereafter. Relay and Audible Bases operate as follows: - The user-friendly maintenance program shows the current state at system power up or reset,the relay is de energized of each detector and other pertinent messages. Single detectors - when a detector is installed in the base with the power may be turned off temporarily from the control panel.Availability of on,the relay energizes for four seconds,then de energizes maintenance features is dependent on the fire alarm system used. - when a detector is removed from a base with the power on, Scheduled maintenance(Regular or Selected)for proper detec- relay is de energized tor operation should be planned to meet the requirements of the -when the detector enters the alarm state,the relay is energized. Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and Isolator Base SIGA-IB,SIGA-164-This base includes a built-in ULC CAN/ULC 536 standards. line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Compatibility The isolator operates as follows: The SIGA-PS detectors are compatible only with the Signature -a short on the line causes all isolators to open within 23 msec Loop Controller. -at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller,the isolators close to provide the next isolator down the line with power Warnings & Cautions -when the isolator next to the short closes,reopens within 10 msec. This detector will not operate without electrical power.As fires fre- The process repeats beginning on the other side of the loop quently cause power interruption,we suggest you discuss further controller. safeguards with your fire protection specialist. Remote LED SIGA-LED-The remote LED connects to the This detector will NOT sense fires that start in areas where smoke SIGA-SB or SIGA-SB4 Standard Base only. It features a North cannot reach the detector.Smoke from fires in walls, roofs,or on American size 1-gang plastic faceplate with a white finish and red the opposite side of closed doors may not reach the detector to alarm LED. alarm it. SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Page 2 of 4 DATA SHEE 85001-0269 Not to be used for installation purposes. Issue 6 Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow,smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors.The table indicates that no single sensing element is suited for all test fires. Edwards recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-IS Ion SIGA-PS Photo Rise/Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without unsuitable unsuitable optimum very suitable very suitable Smoke Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2),#16(1.0mm2), #14 AWG(1.5mm2), and#12 AWG(2.5mm2)wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base,SIGA-SB,SIGA-SB4 Relay Detector Base,SIGA-RB,SIGA-RB4 Normally-Normally- Term Description Remote LED Term Description Common Closed Open p 1 Not Used 1 Normally Open Max resistance 2 DATA IN/OUT(+) 2 DATA IN/OUT(+) 4 j 0 per wire 3 Not Used 3 Common ri_ + must not exceed 4 DATA IN(-) 4 DATA IN(-) 10 Ohms 5 Remote LED(-) e(C 5 Not Used aile 6 Remote LED(+) O s i 6 Normally-Closed ��- � \ 7 Not Used <° 7 DATA OUT(-) %/ X11 8 DATA OUT(-) . 11, —'• ��0 ` 1 ,=,• t1 CONTACT RATING c''�I_7 ' DATA IN(-) A �1=z=a 1.0 Amp Cr?30 VDC / I DATA OUT(-) (Pilot Duty) DATA IN(-I I DATA OUT(-I DATA IN(+) DATA OUT(+) DATA IN I+I DATA OUT(+1 From Signature Controller To Next Device From Signature Controller To Next Device or Previous Device or Previous Device Isolator Detector Base,SIGA-IB,SIGA-1B4 Audible Detector Base,SIGA-AB4G ® o o Term Description (� 1 Not Used Volume setting Tone setting O6 6 0 2 DATA IN/OUT(+) Default=Hi o. 3 DATA IN(-) 0lj�®� Cut for lgh volume Default=Temporal pattern ow volume Cut for steady tone ® 00 4 Not Used 0 .p, 5 Not Usedsew s °"r,"DAT..a ,.. ®64 0 � 6 DATA OUT(-) �T� �T� �T� �T� �T� o - U— • 7 Not Used +--+--+--+--+ 4 1�1�1�1�1�1 To configure output volume Imo,� r l or tone,cut the circuit board DATA IN(-) ` z I Oit itli`C+irli+i DATA OUT(-) as shown. 24 Vdc in _ 1111111 From power supply or + E:;i - 24 Vdc out DATA OUT(+) previous base DATA IN(+) To next base or EOL relay From Signature Controller To Next Device Data in _ or Previous Device From Signature controller or Data out previous device + +To next Signature device Page 3 of 4 DATA SHE L . 85001-0269 Not to be used for installation purposes. Issue 6 Specifications Sensing Element Photoelectric-Light Scattering Principle Storage&Operating Air Velocity Range:0 to 5,000 ft/min(0 to 25.39 m/s); Humidity:0 to A UTC Fire&Security Company Environment 93%RH, Non-Condensing Operating Temp:32°F to 120°F(0°C to Detection&alarm since 1872 49°C); Storage Temp:-4°F to 140°F(-20°Cto 60°C) Sensitivity Range ULI/ULC-0.67%to 3.77% obscuration/foot u.S. User Selected Alarm Most Sensitive: 1.0%/ft.;More Sensitive:2.0%/ft.;Normal:2.5%/ft.; T 888-378-2329 Sensitivity Settings Less Sensitive:3.0%/ft.;Least Sensitive:3.5%/ft. F 866-503-3996 Pre-alarm Sensitivity 5%increments,allowing up to 20 pre-alarm settings Canada Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Chubb Edwards Operating Current Quiescent:45I.iA @ 19 V;Alarm:45pA @ 19 V Emergency Stand-alone T 519 376 2430 Alarm Mode: 18mA Pulse Current: 100 pA(100 msec); During Com- F 519 376 7258 munication:9 mA max. Southeast Asia Construction&Finish High Impact Engineering Polymer-White T:+65 6391 9300 Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base,SIGA-IB Isolator Base, F:+65 6391 9306 Bases SIGA-AB4,SIGA-AB4G Audible Bases LED Operation On-board Green LED-Flashes when polled; On-board Red LED- India Flashes when in alarm Both LEDs-Glow steady when in alarm(stand- T:+91 so 4344 2000 alone)Compatible Remote Red LED(model SIGA-LED)Flashes when F:+91 80 4344 2050 in alarm Australia Compatibility Use With:SIGNATURE Loop Controller T+61 3 9239 1200 Address Requirements Uses one Device Address F+61 3 9239 1299 Agency Listings UL,ULC,MEA,CSFM Europe UL Listed Spacing 30 ft T+32 2 725 11 20 F+32 2 721 86 13 Latin America Ordering Information T 305 593 4301 F 305 593 4300 Catalog Description Ship Wt. Number lbs(kg) utcfireandsecurity.com SIGA-PS Intelligent Photoelectric Detector -UUULC Listed 0.5(.23) ©2010 UTC Fire&Security. All rights reserved. Accessories SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible(Sounder)Base .3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) .1 (.04) a C Page 4 of 4 DATA SHEE 85001-0269 Not to be used for installation purposes. Issue 6 -ST Catalog ► Intelligent Initiating ESTrM NV-Life Safety & Communications Sounder Base /0050401°P— "1****,...dr- Model SIGA-AB4G • *\\ 11/4eN<rvrk i0PIr /1/iyi ( t ) 1.113 r MEA Pending Overview Standard Features The Signature Series AB4G sounder base adds an audible output • Temporal or steady tone function to any Signature Series detector.The base can operate Jumper selects steady or synchronized temporal output. as an independent local alarm, or as part of a zone or system • High or low dB output alarm with synchronized audible output. Jumper selects low or high dBA output. The sounder base matches the finish of Signature Series detec- • Single or group operation tors and the sound output slots complement the smoke/heat entry Optional polarity reversing module configures base for group openings of the detector.The result is a compact unit with an alarm output. attractive appearance. • UL268 and UL464 listed The base generates a loud piercing tone that has excellent wall UL listing under smoke detector and audible signal standards penetration qualities. It uses the same tone generator found in the allows application as smoke alarm and/or audible signal. award-winning Genesis line of wall and ceiling horns. • Attractive installation The AB4G may be configured in the field for either steady or tern- Flush mount to a wide selection of North American boxes or poral output and either high or low dB output. Low dB and steady surface mount to optional custom-matched box. output selections are made by cutting jumpers on the circuit board.The default setting is high dB with temporal output. AB4G sounder bases on the same circuit may be activated as a Application group or zone with the use of a SIGA-CRR polarity reversal mod The Signature Series AB4G sounder base is for use with Signature ule, and the group or zone may be synchronized audible output Series detectors in applications where localized or group alarm with the use of a G1 M RM signal master. signaling is required.The base uses the same address and pro- The AB4G sounder base can simply operate according to the state gramming label as the detector it supports. of its detector,or it can be configured through system programming The base is listed by Underwriters Laboratories under the UL268 to operate in conjuction with all sounder bases on the same circuit, and UL464 standards, allowing its application where both smoke or it can be controlled by program rules.Available operating modes alarms and/or notification appliances are required.This makes the are determined by the system that supports the Signature data AB4G ideal for hotels, dormitories, and other residential occu- loop. pancies where supplementary audible output is required to meet required sound levels for sleeping areas or areas subject to high levels of ambient noise. Page 1 of 4 DATA SHEET 85001-0581 Not to be used for installation purposes. Issue 2 Applications First device Last device Detector operates the base /® ° ° ®\ \® ° ° ®\ AB4G AB4G The base follows the state of the detector, going into and out of - o o alarm with the detector.The Signature CR module is optional, and ° - - ° - is used to silence the bases on the line. a a o o a a th .o 0 0 IIJ1 IIUIII._0 i 0 24 Vdc OM ijYmiM From listed + MEI Listed EOL power supply relay and I®• I ---// — supervising 0 0 0 // module CR lIII III III III Data in + From - Signature controller System turns on all bases First device Last device /® ° ° ® ® ° ° ®\ All bases on the line can be activated by system programming that AB4G AB4G triggers the Signature CRR to reverse the supplied polarity.The oo Signature CR module is optional,and is used to silence the bases o th a Z S on the line. N_ N o 7, 7 ° o 0 —I"III�_I� A 0 IIhI �_ I�_ o 24 Vdc Mild! —Mil From listed + ■ Listed EOL power supply ' ' relay and I®•• I I "lI I --1/ supervising 0 0 0 0 0 0 / module CR CRR Ilwafo'JI lib o ''al Data in + From Signature controller System turns on bases with synchronization First device Last device All bases on the line are activated by system programming that AB4G AB4G 15 triggers the Signature CRR module.The temporal output is syn- o z z o z z chronized by the G1 M-RM. If the Signature CRR module is not . a a i, ; 9 5 activated,each detector can still operate its base, but the bases " I ° ° " " ° will not be synchronized.The Signature CR module is optional, �Q—I_ @ _I,II,�f ]_ I and is used to silence the bases on the line. %/=_ Listed EOL relay and // supervising // module i Pooh II p<boal o o oo G1M-RM CR CRR ®®® 121021 11 1,110il 24 Vdc From listed + power supply Data in + From _ Signature Page 2 of 4 DATA S H E E N 85001-0581 Not to be used for installation purposes. Issue 2 References NFPA 72(2002 edition) Installation and Mounting 7.4.2 Public Mode Audible Requirements. Flush Mounting:The sounder base flush mounts into 2-1/8 inch 7.4.2.1 To ensure that audible public mode signals are clearly (54 mm)deep standard North American 4 inch square electric box, heard... they shall have a sound level at least 15 dB above the North American 4 x 4 inch octagonal concrete ring(mud box),and average ambient sound level or 5 dB above the maximum sound standard European 100 mm square electric boxes.The terminal level having a duration of at least 60 seconds, whichever is block makes field wire connections fast and efficient.After wiring,a greater, measured 1.5 m(5 ft)above the floor in the occupiable simple push and twist motion locks the Signature detector into the area, using the A-weighted scale(dBA). • base. 7.4.4 Sleeping Areas. / \ 7.4.4.1 Where audible appliances are installed to provide signals O 0 ( _lir 11_ for sleeping areas, they shall have a sound level of at least 15 dB L. u u u above the average ambient sound level or 5 dB above the maxi- mum sound level having a duration of at least 60 seconds or a z (�/ sound level of at least 75 dBA, whichever is greater, measured at Electrical Box ' the pillow level in the occupiable area, using the A-weighted scale ) _,---P--- (dBA). �--(dBA). �_,.11lilial ';� AB4G-SB L I lir 1 Optional Surface Box Configuration and Wiring .w ow-_,_ro. (6.8"diameter x 1.8"deep) Volume setting Tone setting Base Plate j Default=High volume Default=Temporal pattern Cut for low volume Cut for steady tone Edwards recommends that + t:�� y. fire alarm systems and their 4111111111 z devices always be installed ,I —I— �,,I� in accordance with the lat- �� Trim Ring est recognized edition of 1 national and local fire alarm To configure output ® volume or tone,cut codes. DATA-DATA-DATA. the circuit board as SIG+ SIG- OUT IN IN/OUT shown. lfiiIii1 11 c ignormernmrmermerral, Vii.7/170' 1111111 Detector 24 Vdc in - ■-■' - 24 Vdc out From power supply or + + To next base or EOL relay previous base III t - Data in _ Data out From Signature controller or To next Signature device previous device + + Sound Level Output Signal Voltage Low dBA High dBA Reverberant room per UL 464* 16 Vdc 71.5 78.1 Temporal 24 Vdc 75.5 80.7 33 Vdc 78.5 83.1 16 Vdc 75.5 81.7 Steady 24 Vdc 79.5 84.5 33 Vdc 81.8 86.5 Reverberant room per UL 268 16 Vdc 77.5 84.1 Temporal 24 Vdc 81.5 86.7 33 Vdc 84.5 89.1 16 Vdc 81.5 87.7 Steady 24 Vdc 85.5 90.5 33 Vdc 87.8 92.5 dBA=Decibels,A-weighted "For UL 464 applications low dBA settings are for private mode only. Page 3 of 4 DATA SHE L . 85001-0581 Not to be used for installation purposes. Issue 2 Specifications TOWARDSOperating Voltage 16-33 Vdc, 16-33 Vfwr(continuous voltage required for temporal output) A UTC Fire&Security Company Supervisory Current DC=1.46mA;FWR=2.15mA Detection&alarm since 1872 Operating Current in mA 16 Vdc 24 Vdc 33 Vdc 16 Vfwr 24 Vfwr 33 Vfwr U.S. (RMS) T 888-378-2329 Low dBA 17 24 31 41 51 60 F 866-503-3996 High dBA 28 41 52 48 60 66 Canada Chubb Edwards Output volume:high dBA Output tone:temporal pattern(0.5 s T 519 376 2430 Default Settings on,0.5 s off,0.5 s on,0.5 s off,0.5 s on, 1.5 s off,repeat cycle). F 519 376 7258 Operating Temperature:32°to 120°F(0°to 49°C) Southeast Asia Environmental Operating Humidity:0 to 93%RH T:+65 6391 9300 Storage Temperature:-4 to 140°F(-20 to 60°C) F:+65 6391 9306 Wire Size 12 to 18 AWG(2.5 to 0.75 mm2) India Compatible Detectors All Signature Series Detectors(SIGA-IPHS,SIGA-PHS,SIGA-IS, T:+91 80 4344 2000 SIGH-PS,SIGA-HFS,SIGH-HRS) F:+91 80 4344 2050 AB4G-SB Surface Box for Audible Bases,North American 2-1/8 Compatible Electrical Boxes in(54 mm)deep 4-inch square box, North American 4 by 4 inch Australia octagonal ring(mud box),Standard European 100 mm square T+61 3 9239 1200 box F+61 3 9239 1299 Dimensions Base diameter:6.8 in(173 mm). Europe Base height from box:0.8 in(21 mm) T+32 2 725 11 20 Wall mount applications Distance from ceiling 12 in(305 mm)maximum F+32 2 721 86 13 Meets or exceeds requirements specified in UL 268,UL 464, Agency Listings and ULC-S525.(MEA,CSFM pending) Latin America T 305 593 4301 F 305 593 4300 utcfireandsecurity.com Ordering Information ©2010 UTC Fire&Security. Catalog Number Description Ship Wt.,lb.(kg) All rights reserved. SIGA-AB4G Audible(Sounder)Base 0.3(0.15) AB4G-SB Surface Box for Audible Base 1.0(0.45) Related Equipment SIGA-MCRR Polarity Reversal Relay (Plug-in UIO module) 0.18 (0.08) SIGA-CRR Polarity Reversal Relay (Standard mount module) 0.2 (0.1) SIGA-MCR Control Relay Module (Plug-in UIO module) 0.18 (0.08) SIGA-CR Control Relay Module (Standard mount module) 0.2 (0.1) G1M-RM Signal Master (1-gang remote mount) 0.2 (0.1) a Page4of4 DATA SHEE 85001-0581 Not to be used for installation purposes. Issue 2