Loading...
HomeMy WebLinkAboutA15-0057_Silent Knight 5820XL_1434727920.pdf INTELLIKNIGHT FIRE ALARM CONTROL PANEL 4/0 SILENT IntelliKnight° Model 5820XL KNIGHT Addressable Fire by Honeywell Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling j N line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol iwkhae= • Built in support for 127 SD devices, expandable to 508 SD 7..1%1 h devices using the SD protocol. "J'" • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum Gentex®, Faraday, System Sensor, and Wheelock® charging l cabinet of c5 amphoursrequired cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming.You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows°- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared in compliance with standard wiring programming.The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility. The communicator cables. No special wiring is required. supervises two phone lines and will 5820XLprovides 13preset notification activate a trouble signal if a line failure System Application is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID. The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- multiple device types, including: account number. programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. • W..Q- detector �;;`;� User Interface - - • Addressable heat sensor 'The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large easy-to-use tactile touch ad can be or. !b- • Contact module Y- p • Relay output module used for system operation, Q V programming and maintenance. It has iv q+ m • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, Approvals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming. The JumpStart®feature MEA 429-92-E Vol. VI; FM Approved minimizes programming INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL W°dFaBased cillity Addressable Fire Alarm System Management Software SK(System Sensor) Protocol Devices U Mndows Based Up/Down load Software - 0R ® Compatible CS r al■e■ .- -t T : Receiver [ -—"\� Automation 0.FR 5 • wpm Internet 5820XL SK-212UD Connection VisorAlarm IP Communicator 5895XL Ir.li9 --„,—rldredule 3 Form C Relays 4 3 Form C 120ays 4 ' ' Event Printer Ce _ Parallel ■ 5815XL .3 R5-C3t 1-1A SLC Recorder_ _ 5860 5824 Remote Annunciator PrinterlGatenar Module r',va” (211nits MatdSystem) � . -? F 6 Flexput- _ I/O Circuits 815XL rscan be inputs CLO Expander or outputs rn — 6 Flexput'- LT W Grunts F can be inputs r' ' or outputs 1111) ril W. u eells.sonoes.E ns,ana NAca W. 0 Pall smarts canVeln ui so nea strut.oe@[to'S 1 .1/ la SK-Ion SK-Monitor SK-Iso SK-Control-6 SR-Control B200SR SK-Acclimate SK-Zone-6 V Addressable Addessable Fault Isolator Addressable Supervised Sounder Mubicntena Zone loazdion Monitor Module Nonlcation Control B.0 smoke Interface 5860 Detector Module module Module detector Module Remote Annunciator I SK-Photo SK-Monitor-2 SK-Relaymon-2 SK-Heat B224RB 622401 B210LP 5880 6K-Photo-T Dual Mon rtor Addressable SK-Heat-BOR Relay solani ereerm Addressable Module Duel Monitor SK-H eat-HT Bose Bare BoreLED Driver Fnotoeloetnc RAT Relays Addressable Input Module Detector Heat detectors 41lit l* '11' ''' . . . I I I I Relay Interfrfae Modile SK-Beam SK-Mon-10 SK-Pull-DA SK-Duct SK-Ninimon SK-Relay-6 SK-Zone SK-Relay SKBeam-T Adutesseble SK-Pull-6A Adctessable Monitor Relay Conn! Adcressable Adrtesseble Addressable Monitor Addressable Duct Module Module Interface Relay Beam Ceteeter Module Pull Station Daector Module Module 5865-4 or 5865-3 I Use the 5380 to control up to 4 , (5865-4�c � 1 5883 Relay Interface Modules INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"DFeatures 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder. The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X (two required) reports, and event history. Interfaces with building control system. This document is not intended to be used for installation purposes.We try to keep our SILENT Made in America 44 KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. ©2012 Honeywell International Inc. IntelliKnight&Jumpstart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight