HomeMy WebLinkAboutA15-0060_FA-0_1436281800.pdf r 3QO Vail Fire&Emergent Services 07/07/15 AHJ - Vail Fire Department BATTERY CALCULATIONS IFC2012 Occupancy Class - Residential multi- SYSTEM OUTPUTS LOCATION: 1st Level Mechanical family 907. 2. 11 . 2 Group R- 3 R - 3 R - 4. Single o r CONTROL PANEL HOURS OF SUPERVISION: 24 HOURS NOTIFICATION SAFETY CONTROLS PANEL: ADEMCO 128BPT MINUTES OF ALARM: 15 MINUTES multiple station smoke alarms shall be ANNUNCLTION Device Device Total installed regardless of occupant load at Total Alarm QTY PARTNUMBER Supervisory Alai n Supervisory o DESCRIPTION OF DEVICES Current Current Current Current all o f the following locations: o 1 ADE-128BPT FACP 0.25000 0.33000 0.25000 0.33000 1 . On ceiling or wall outside each separate y 1 ADE-4204 4 zone relay card 0.01500 0.16000 0.01500 0.16000 C 1 ESL-204 12/24 End of linepower Supervision Module 0.00000 0.01400 0.00000 0.01400 Property: sleeping area. r 1 ESL 405-05 ESL Reversal Relay 0.00000 0.03400 0.00000 0.03400 N �' 1183 Cabin 2 ADE 4208U 8 Zone Expansion Module 0.02730 0.02730 0.05460 0.05460 2. In each room used for sleeping _ Q o 1 ADE-6160 Annunciator 0.04000 0.15000 0.04000 0.15000 0 `� �' 0 y: 3. In each story within dwelling unit C ti L o . Circle 11 SYS-C012241R Monitored Carbon Monoxide Detector 0.00200 0.04000 0.02200 0.44000 .- ¢ , 15 ESL 541NCSXT Monitored Smoke Detector 0.00200 0.0400© 0.0300© 0.60000 VA I L FIRE INSTALLATION STANDARDS: cj Q g ~ I f VD rn o C Z p _ 29 ADE 4193SN Addressable Modules 0.00150 0.00150 0.04350 0.04350 d > ,t < E "' 1 SYS-MHW Interior Siren 0.00000 0.07500 0.00000 0.07500 1 . Smoke detection required in living rooms, = o " Cl y Address: 1 SYS P2RK Exterior Horn Strobe 0.00000 0.21800 0.00000 0.21800 d d o o =r =r, 6 o ¢ ° - p4 b, -� s~ r 1183 Cabin Circle, Vail, CO 1 SYS-5603 135 degree fixed heat detector 0.00000 0.00000 0.00000 0.00000 family rooms and home theaters. v. Cl .K J s . ' - 81657 a� C) C) y v .0 Cl .F. a o , o C C o 1 MAC-GD2A Combustible Gas Detector 0.04500 0.07000 0.04500 0.07000 s~ C a S. o C t, .� N ,4 TOTAL: 0.50010 2.18910 2. Boiler Mechanical rooms required heat detectors. g n H H W y y a w o cuu u u - u u y B I B o 0 0 0 Owner: SUPERVISORY: Cl Cl Cl Cl Cl Cl Cl Clm m Cl Cl C 3. Storage rooms not req d to have smoke detection . J . ? Cl Cl Cl Cl C) C) C) C c SUB-TOTAL: 0.50 AMP C) C) C) - •C) � C) C) C) Cl Cl °' °' �' °' 0 24 HOURS OF SUPERVISORY: 24.00 HOURS 4. Garages shall have a sounder. < < < < H �" E" �" W x Smoky or Heat.Detector X X X X X X SUB-TOTAL: 12.00 AMP HOURS ALARM: 5. Smokes/Heats shall be oriented to center of area . Carbon Monoxide Detector X X X X X X General Contractor: SUB-TOTAL: 2.19 AMP 6 . C O required i n kitchens and indoor fireplaces. Ground Fait X X Scott S. Turnipseed 15 MINUTES OF ALARM: 0.25 HOURS open circuit X X x1143 Capitol St, Suite 211 SUB-TOTAL: 0.55 AMP HOURS 7. Crawl spaces do not require heats unless there is Notification Circuit Trouble X X X X P.O. Box 3388 TOTALS: Eagle, Colorado 81631 TOTAL, SUPERVISORY: 12.00 AMP HOURS mechanical equipment installed. Low Battery X X X x 970-328-3900 TOTAL ALARM: 0.55 AMP HOURS AC Power Failure X X X X TOTAL: 12.55 AMP HOURS *SPARE OF 20% 2.51 AMP HOURS Telephone Line Fault-daily timer test X p Code Com lienee: MINIMUM BATTERY SIZE REQUIRED 15.06 AMP HOURS Remote Power Supply Trouble Condition 2012 International Fire Code BATTERIES SUPPLIED 2 x 8 anp 16.00 AMP HOURS f Panel Silence Feature X X 2010 NFPA-72 Nat. Fire Alarm Code S yS t o r"1 C o c e e f e r e rl C e - sprinkler Flow X X X X X 2011 NFPA-70 Nat. Electrical Code BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL - Vail Fire Ammendments Levels: 3 Levels Bldg Height: 25'f Roof Height Occupancy Loads: ANN EOLRI <- CID x 6 C0 x 4 THIRD FL00R Approved for install Occupancy Rating: AIM x 6 OAIM x 4 R-2 Residential Structure: _< L< I 9 x 3 CO x 3 SECOND FLOOR Type II/Non-Rated/Sprinkled °AIM x 3 OAIM x 3 Sq. Footage: 11806 SgFt± Bell 1 Aux Pwr 0135° CO ax 6 Communication Type: x 5 FIRST FLOOR DACT/POTS Lines Ademco OAIM CAN x 50AIM x 6 Primary Power Location: 128BPT Main Elec Panel -Breaker : FACP FDC PANEL Designed and Installed by: 1 SLC OAIM CAI °AIM SPRINKLER RISER SYSTEM i Phonelines (1) 120 VAC Dedicated 41 1- -i f-{ -4. 12VDC 8 AH Batt Backup d Superior Alarm & Electronics 210 Edwards Vill. Blvd. #A108 Edwards, CO 81632 PH 970-926-8788 FX 970-926-8790 brad@superioralarmco.com SYMBOL DESCRIPTION API DESCRIPTION CLASS STYLE TYPE FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE REMOTE STATION SIGNALING LINE CIRCUITS/POWER B -f 4 4 #18 AWG FPLR SYS# 6101-1759 ap New construction single family residence is being constructed in the Town NOTIFICATION ALARM CIRCUIT/POWER B Y 4 #14 AWG FPLR SMOKE DETECTOR (PHOTOELECTRIC) HORN/SOUNDER 135° � HORN WITH STROBE NATIONAL INSTITUTE FOR CERTIFICATION of Vail . Residences will be fully s p r i n k l e r e d and a monitored fire INITIATING DEVICE CIRCUITS D 4 #18 AWG FPLR OO HEAT DETECTOR FIXED/ROR (TEMP LISTED) FM IA""15 (NUMBER INDICATES CANDELA) IN ENGINEERING TECHNOLOGIES ANN ANNUNCIATOR 15 Fire Protection Engineering Technology alarm system will be installed with monitored carbon monoxide RS 485 (SBUS) 4 #18 AWG FPLR STROBE (NUMBER Fire Alarm Systems detectors. USE PLENUM RATED WIRE IN ALL PLENUM SPACES tZi WATER FLOW SWITCH INDICATES CANDELA) END OF LINE RESISTOR 0 WIRE CHART f--i VALVE WITH TAMPER SWITCH EOL RE I zc ) I ADDRESSABLE INPUT MODULE FIRE DEPARTMENT "KNOX" BOX S C O e O f Wa r I� ()AIM CO MONITORED CARBON MONOXIDE DETECTOR George Sharer NICET # 98481 Level III C LEGEND Valid Thru 5/1/2017 ORIG.6/17/15 SCALE: 1/8"=1'0" R//E��V. DATE NOTES: /z\ • FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan Index: Permit #: PAGE NAME: Title/Bldg/Calcs/Map AHJ : Vail Fire Department - Flre Marshal Mlke Vaughan 970 . 479 . 2252FA-0 Cover Page A O SHEET 1 OF 4