HomeMy WebLinkAboutA15-0060_FA-1_1436281800.pdf r
v.f..,,
3Q0.
Vail Fire&Emergenc Services
07/07/15
I
l—
I I
GFIO GFP GFP GFP I
— I
I
PAR I
0\ j
® ®
WOOF` 1 rRYWALL
CLG+0'6" CLG+9'6"
0,< il
O ® I O GFI
-- /�, i i----- iW, Property:
I — II It II It II I i 1183 Cabin
I
I . 5 0 o �� WOOF`0CLG+19'5;" Circle
I r_.-/ rRYWALL �� sl_1-on-_r_(Toy of concrete INCLG+f'6" .eto
- - - - - � J I I un.lrsi.e of structure,
T ►OW ER GFI(' - V"
-r - _ Address:
L
0 Prov(/e /u-lex o _ _ c c+� 3 o. 71,______
1183 Cabin Circle, Vail, CO
1-0-0
outlet,sconce I ��� I�i o LC
in A switch At �. n =E___ _———— - �V n L rRYWALL o 1 vJ�
e ich i'unk f e/. 1 0 swith_t I_n.in. _ ova ^y{ / a fb, CLG+�'6"
ITT
_ Owner:
r n ELEV. — GA E ROOM
/_,1IIIIL �� sn 0
PUNK ROOM I � 'RYWALL 0 I OD
CLG+10'5;' �� r`--- -- ��� I_ II ti MI
O GFI
To second floor I s '� woos iiiiir E�►nn
PR , ALL O ■ ■ ___ --- - - - -I General Contractor:
O �. SP 7 \ / Co; +S' M 1- --- 1 , I Scott S. Turnipseed
s� r A 0" -ice ���� I sn ��' '� m, '�' I 1143 Capitol St, Suite 211
o .�� 5 �� T_ A� �' ��j _ .�..7G� �� @ I P.O. Box 3388
—�——t; �'YWAL rRYWALL , rRYWALL ►tet z Eagle, Colorado 81631
CLG+9'6" CLG+9'6" ,•on-,EAM ��� CLG+9'r ►a. I��
Irl ��� �� ® ® ��� 970-328-3900
QJ�� QJ�p 1 o o o O ���
J r'GFI ^ GFI A I �•' •'I I
F +4 — - - - - i- � �, Code Complience:
CHANICAL —'
EXERCISE ROOM
5` UNFINISHEr �' �, RYWAL ALL •!iJPP)PIPP. 2012 International Hire Code
C �^ f / F CG+ "" UNK ATH _ CLG+105; � 2010 NFPA-72 Nat. Fire Alarm Code
0 o F0 1111,31 O `v. CO TO SECOND FLOOR o � V = 2011 NFPA-70 Nat. Electrical Code
--- -- —I tl- rRYWALL 0 0
•
SHOWER Vail Fire Ammendments
-
CLG+9'0" U N EXCAVATEr
FACP Levels:
Tofixture_iov=_n. 3 Levels
ELEC.PANEL O
O GFI 6 GFI switch_t _n.n_ i ovs. I GFI GFI •� 1�1 1�1 1�1 1�I
III ♦ 0 111
rRYWALL Bldg Height:
— —
CLG+9'6"
_� '- -' 25'f Roof Height
Op
I j j `r — / nEr o . o. ��• Occupancy Loads:
IR " YWALL
0 11
1
1104
' S� CLG+10'5;"
�� - I Occupancy Rating:
TO OUTSIDE HORN STROBEA -
TO SECOND FLOOR / I� I R-2 Residential
DI r i_� Li • O L _
■ �rLL I Structure:
P_ -- CL )'9" �- �� II Type II/Non-Rated/Sprinkled
`' ,I
UNEXCAVATEr I / 11 M — f '1 r� n j- - - ------ - - - - -------- - - -------- Sq. Footage:
�..L s^ I 1 11803 S Ft±
I _ �� Z\),9 Sq
Ft
rRYWALL :•: a e, a r.
J _ CLG+S'0" Interior c I n tin/floor ictiv it®I) i Communication Type:
DACT/POTS Lines
IN0: ----—----- I M 0' Primary Power Location:
0 I_ 55 = WOOF` Main Elec Panel -Breaker
CRAWL SRACE rRYWALL CLG EX►OSE/`TSG
CLG+�'0" o Designed and Installed by:
5'-O"c1_ m_x. F \
‘5)1I
I- -I I- -IGF$ PErROOM NO. 5 \ tc= 1
PATH NO 5 rRYWALL _
FIRST FLOOR REFLECTIVE CEILING PLAN ■ ° if w� bl . LG+10'5; L
I
Superior Alarm & Electronics
1 rRYWALL 210 Edwards Vill. Blvd. #A108
I CLG+t9
I u o Ewards, CO 81632
rt 1- -1 PH 970-926-8788
■ e _ _ 0.6 _ FX 970-926-8790
I- brad@superioralarmco.com
I
LI----
- - - - - - - -
API
REMOTE STATION
SYS# 6101-1759
NATIONAL INSTITUTE FOR CERTIFICATION
IN ENGINEERING TECHNOLOGIES
Fire Protection Engineering Technology
Fire Alarm Systems
'rnIcZ.5- liS
George Sharer
NICET # 98481 Level III
Valid Thru 5/1/2017
ORIG.6/17/15 SCALE: 3/16"=1'0"
R/�EV. DATE NOTES:
A •
/2\ •
FINAL INSP.
AS BUILTS:
AHJ: Vail Fire Department
Mike Vaughan
Index: Permit #:
PAGE NAME: Title/Bldg/Calcs/Map
FA- 1 Lower Level A 1
AHJ : Vail - Flre Marshal Mlke 970 . 479 . 2252
SHEET
1 OF 4