HomeMy WebLinkAboutA15-0061_A-FA000_1437147180.pdf 41° Cir I/4 4. X Address Type of Device Level Description LEGEND : Arm 0 001 MONITOR MAIN SPRINKLER WATERFLOW 002 MONITOR MAIN SPRINKLER TAMPER SWITCH SYMBOL DEVICE MANUFACTURER/PART# MOUNTING Vail Fire&Emergency Services 07/17/15 003 CO/SMOKE DETECTOR MAIN REC ROOM FACP Caddx (NetworkX) NX-8E 004 SMOKE DETECTOR MAIN MASTER BEDROOM Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox 005 CO/SMOKE DETECTOR MAIN ENTRY OUTSIDE MASTER 006 CO/SMOKE DETECTOR MAIN HALL OUTSIDE BEDROOMS KP 007 SMOKE DETECTOR MAIN NORTH BEDROOM LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox 008 SMOKE DETECTOR MAIN SOUTH BEDROOM 009 HEAT DETECTOR UPPER GARAGE Combination Smoke & 010 CO/SMOKE DETECTOR UPPER FAMILY ROOM Q Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4" square box 011 CO/SMOKE DETECTOR UPPER LIVING ROOM 012 Combination Smoke and 013 OwCO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 014 015 O System Sensor 5601P 016 Heat Detector w/4193SN Addressable module 4" square box z 017 0 1= 018 ECosmo Interface Module COSMOD4W 019 0 020 co KB 021 Knox Box z 022 0 023 024 aHorn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox i 025 NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. . w 1— Battery Calculations 0 Caddx NX-$E Standby Number of Current Total Current z Device Type Devices (Amps) (Amps) D = 4—WIRE DATA/POWER, 4—#16AWG (2 PAIR) Main FACP CPU 1 X 0.075 = 0.075 -NX-14E LCD Keypad 2 X 0.075 = 0.15 X = 2—WIRE DATA, 2—#16AWG CO w NX-2192 Addressable Interface Card (max draw) 1 X 0.17 = 0.17 o Z SUM COLUMN FOR STANDBY LOAD 0.395 = 'AMPS N = 2—WIRE SOUNDER CIRCUIT, 2—#18AWG rn Alarm Load Z = 2—WIRE DATA CIRCUIT, 2—#16AWG o a Number of Current Total Current EOL EOL Device Type Devices (Amps) - (Amps) KP = KEYPAD CIRCUITING, 4—#18AWG 21co > 0) of oo Main FACP CPU 1 X 0.14 - 0.14 RISER NOTES: c 1--- 0 NX-14E LCD Keypad 2 X 0.11 = 0.22 _ J NX 21920.)Addressable Interface Card 1 X 0.17 = 0.17 D D L _1 Sounders (integral with detectors) 8 X 0.015 = 0.12 1. REFER TO PANEL INSTALLATION MANUAL FOR Outside Horn/Strobe 1 X 0.239 = 0 23g MORE INFORMATION. L1 SUM COLUMN FOR ALARM LOAD 0.889 - AMPS 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS NX-8E L,N L,N c N MANUFACTURERS SPECIFICATIONS. CONTROL PANEL 0V) Standby Load Required Standby Time in Hours 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (NP) (NP) C Current (Amps) PRIOR TO INSTALLATION. WIRING DIAGRAM IS 0.395 X 24 = 9.48 INCLUDED SUBMITTAL BOOKS. 4193 Z 10 Alarm Load Required Alarm Time in Hours C Current (Amps) (15 MINUTES) 120VAC DEDICATED POWER 0.889 X 0.25 = 0.22 4193 Z FLOW SWITCH Add Standby and Alarm Load for Required Z Ampere Hour Battery 9.70 4193 TAMPER SWITCH C Multiply by the Derating Factor of 1.2 I I - TELEPHONE LINE N WP Total Ampere Hours Required 11.64 BELL EOLR OUTPUT + Batteries Provided: 12AH 0 L. Note: The maximum draw for the NX-2192 Addressable Interface Card was used, This accounts for all RISER DIAGRAM DAOUTPUM KP KEYPAD KEYPAD N initiating devices (smokes and heats)attached to the system. Therefore, each device is not individually a) + lo accounted for. 0d- C '- o i1 00 0 GENERAL NOTES: 0N 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH 0 r — CC o 0 o MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. CO ,. 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR m 0 FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, ,, m PROGRAMMING AND DEVICE OPERATION. 0_ u_ 00 + , v iot ��ll r r, 3523 - ,;c:11,--, te.• - :: 0 :4' . • IONP1 0 PROJECT INFORMATION : z 401 HEAVER DAM ROAD , UNIT A = SEQUENCE OF0 Q w w cn OPERATIONS: N J z Z VAI L, COLORADO Q = w < o 5o (no FIRE ALARM SYSTEIV J C9 1 w 1,77 H (n M z0 Q F m NQ ¢ wQ w L.L D r cn a o o 0 z w o AHJ: VAIL FIRE & EMERGENCY SERVICES Z 2 0 v Q z N z z w w CO APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC W W Q E � w Q I I- 0 .. W ,� 1- o 1- o 1- o o c� ow OCCUPANCY: GROUP R CCI— w � z � z � z w l w w 0 DEVICE a No No r„ o QN ao a� USE: DUPLEX Q p zM z DESCRIPTION >— Q Q Q > w > z > z O < Q cto w o Eto a m a o 0 o FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM WILL INCLUDE A NEW i co l— l— l— l— l— H ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE w 0 SMOKE DETECTOR X X X INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON cL > J Q Cl W STAIRWELL LANDINGS AND AREAS OUTSIDE OF SLEEPING ROOMS. A HEAT < 0 J z HEAT DETECTOR X X X DETECTOR WILL BE INSTALLED IN THE GARAGE. DETECTORS HAVE W 0 < 0 INTEGRAL SOUNDERS. A KNOX BOX AND OUTSIDE HORN/STROBE WILL CO J w CARBON MONOXIDE DETECTOR X X X BE MOUNTED AT THE FDC. THE HOME IS SPRINKLERED AND THE FACP N— Q 0 W WILL MONITOR FLOW/TAMPER. > LL 0 SPRINKLER WATERFLOW SWITCH X X X X FIRE PROTECTION ENGINEER: SHEET DESCRIPTION: DEBORAH SHANER, P.E., SHANER LIFE SAFETY FIRE ALARM PLAN SPRINKLER TAMPER SWITCH X X PO BOX 1073, FRISCO, CO 80443 PHONE: 970-409-9082 DRAWN BY: DATE: POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X FAX: 970-797- 1898 DLS 6/16/15 SHEET#: FA-000