HomeMy WebLinkAboutA15-0062_B-FA000_1437147360.pdf ° CliI/4 X LEGEND . Arm SYMBOL DEVICE MANUFACTURER/PART# MOUNTING Vail Fire&Emergency Services 07/17/15 FACP Caddx (NetworkX) NX-8E Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox KP LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox O Combination Smoke & Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4" square box Combination Smoke and Address (Type of Device Level Description 0co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box 001 _MONITOR LOWER SPRINKLER WATERFLOW 002 MONITOR LOWER SPRINKLER TAMPER SWITCH O System Sensor 5601P 003 CO/SMOKE DETECTOR LOWER LOWER LEVEL HALLWAY Heat Detector w/4193SN Addressable module 4" square box 004 SMOKE DETECTOR LOWER NE BEDROOM z O_ 005 SMOKE DETECTOR LOWER NW BEDROOM 0 Cosmo Interface Module COSMOD4W 0 006 CO/SMOKE DETECTOR MAIN HALL OUTSIDE GARAGE E 0 007 HEAT DETECTOR MAIN GARAGE w 008 CO/SMOKE DETECTOR UPPER HALL OUTSIDE MASTER 111 Knox Box 0 009 CO/SMOKE DETECTOR UPPER LIVING ROOM O_ 010 SMOKE DETECTOR UPPER MASTER BEDROOM 011 Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox > 012 013 014 015 016 w 017 Q 018 0 019 020 021 z z 022 D = 4-WIRE DATA/POWER, 4-#16AWG (2 PAIR) 023 024 X = 2-WIRE DATA, 2-#16AWG c I- 025 O Z N = 2-WIRE SOUNDER CIRCUIT, 2-#18AWG a' NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. Z = 2-WIRE DATA CIRCUIT, 2-#16AWG O Q EOL EOL KP = KEYPAD CIRCUITING, 4-#18AWG ? I o CO p 0 RISER NOTES: C rn 0 _ 1. REFER TO PANEL INSTALLATION MANUAL FOR D D 0L j Battery Calculations MORE INFORMATION. %•I ° (/) Q 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS L,N L,N 0 0- z Caddx NX-8E MANUFACTURERS SPECIFICATIONS. NX-8E 0 C v) Standby 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W CONTROL PANEL (NP) (NP) Number of Current Total Current PRIOR TO INSTALLATION. WIRING DIAGRAM IS Device Type Devices (Amps) (Amps) INCLUDED SUBMITTAL BOOKS. 4193 Z 10 Main FACP CPU 1 X 0.075 = 0.075 C NX-14E LCD Keypad 2 X 0.075 = 0.15 120VAC DEDICATED POWER (1) WNX 2192 Addressable Interface Card (max draw) 1 X 0.17 = 0.17 4193 Z FLOW SWITCH SUM COLUMN FOR STANDBY LOAD 0.395 = AMPS Alarm Load 4193 TAMPER SWITCH t- C Number of Current 1Total Current TELEPHONE LINE N WP _As.Type Devices (Amps) (Amps) BELL EOLR Main FACP CPU 1 X ' 0.14 = 0.14 OUTPUT + NX-14E LCD Keypad 2 X 0.11 ' = 0.22 DATA COM KP 0 NX 2192 Addressable Interface Card 1 X 0.17 = 0.17 RISER DIAGRAM OUTPUT KEYPAD KEYPAD N Sounders (integral with detectors) 7 X ' 0.015 ' = 0.105 (1) 4- Outside Horn/Strobe 1 X 0.239 = 0.239 W ro SUM COLUMN FOR ALARM LOAD 0.874 = AMPS C '- o Standby Load Required Standby Time in Hours co Current (Amps) O 0.395 X 24 = 9.48 0Q Alarm Load Required Alarm Time in Hours GENERAL NOTES: N 1 Current (Amps) (15 MINUTES) r — 1.0 0 0.874 X 0.25 = 0.22 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH 0 0 o Add Standby and Alarm Load for Required MANUFACTURER STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72. (1) x— Ampere Hour Battery _ 9.70 2. REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR ° o Multiply by the Derating Factor of 1.2 FURTHER INFORMATION REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, m N Total Ampere Hours Required = 11.64 o E p q BatteriesPrvvided: 2AH PROGRAMMING AND DEVICE OPERATION. 0_ u_ ,..- ‘ ,i9,15% ., .,,,,:,.%-v,.. 2 : 0 , , „ rs: $ '...,, v. , -4 + Ili Ili PROJECT INFORMATION : z 401 3EAVER DAM ROAD , UNIT 3 s SEQUENCE OF Q w cn OPERATIONS: N a Z } z Z VAIL COLORADO co = LL; N Q w Q o FIRE ALARM SYSTEM 1 D f a o o 0 z w o AHJ: VAIL FIRE & EMERGENCY SERVICES Z 2 0 Q Z N z Z w w CO APPLICABLE CODES: 2010 NFPA 72, 2012 IFC, 2012 IBC W w Q E � w Q I I- 0 .. W o < o 1- o 1- o o < o ct OCCUPANCY: GROUP R ~ w � Z � Z � ZWI w w � O C/) 0 DEVICE a v, o U, o („ o QN Qo a� USE: DUPLEX Q 0 zm zm DESCRIPTION >— Q Q Q > w > z > z O < a o o o Q m a o a o FIRE ALARM SYSTEM FOR DUPLEX UNIT. SYSTEM WILL INCLUDE A NEW l- I- 1- 1- l- H i r2 2 co ADDRESSABLE FACP. COMBINATION SMOKE/HEAT DETECTORS WILL BE W 0 SMOKE DETECTOR X X X INSTALLED IN SLEEPING ROOMS WITH SMOKE/HEAT/CO DETECTORS ON cL > J Q Cl W STAIRWELL LANDINGS AND AREAS OUTSIDE OF SLEEPING ROOMS. A HEAT < 0 J z HEAT DETECTOR X X X DETECTOR WILL BE INSTALLED IN THE GARAGE. DETECTORS HAVE W 0 < 0 INTEGRAL SOUNDERS. A KNOX BOX AND OUTSIDE HORN/STROBE WILL CO J w CARBON MONOXIDE DETECTOR X X X BE MOUNTED AT THE FDC. THE HOME IS SPRINKLERED AND THE FACP N— Q 0 W WILL MONITOR FLOW/TAMPER. > LL 0 SPRINKLER WATERFLOW SWITCH X X X X FIRE PROTECTION ENGINEER: SHEET DESCRIPTION: DEBORAH SHANER, P.E., SHANER LIFE SAFETY FIRE ALARM PLAN SPRINKLER TAMPER SWITCH X X PO BOX 1073, FRISCO, CO 80443 PHONE: 970-409-9082 DRAWN BY: DATE: POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X FAX: 970-797- 1898 DLS 6/16/15 SHEET#: FA-000