HomeMy WebLinkAboutA15-0064_Mircom DETECTOR BASES_1437499680.pdf A1. MIRcQM®
MOUNTING BASES 200 SERIES
Mircom's mounting bases and kits provide a variety The MIX-200 Series detectors can be mounted in
of ways to install detectors in any application. either flanged orflangeless bases depending on the
junction box selection.
•
B501 Flangeless Mounting Base B501 BH Sounder Base
The 6501 is standard base with no flange. The B501 BH Sounder Base provides a built-
in sounder which can be used for evacuation
purposes.
. ;.
I_ A , -- r 1
•
•
B210LP Flanged Mounting Base B224RB Relay Base
The B210LP is a low profile mounting base with a The B224RB Relay Base provides one form C relay
flange. contact for control of auxiliary functions such as
damper control and elevator recall.
•
•
v 51`rNC
B224BI Isolator Base
The B224BI Isolator Base allows loops to continue UL (foril 411>
to operate under fault conditions and automatically APPROVED
restore when the fault is removed.
CATALOG NUMBER 5906
NOT TO BE USED FOR INSTALLATION PURPOSES. �1 V
Mircom reserves the right to make changes at any time without notice in prices,colours,materials,components,equipment,specifications and models and also to discontinue models.
Specifications
Base Specifications B224RB/B224B1 Electrical Ratings B501BH/B501BHT Electrical Ratings
Diameter Operating Voltage External Supply Voltage
4.0"(102 mm);flangeless 15 to 32 VDC 17 to 32 VDC
6.1"(155 mm);flange
Standby Ratings Standby Current
Height <500 pA maximum @24 VDC 1.0 mA max.
1.2"(31 mm)
Set Time Alarm Current
Wire Gauge 4 sec.minimum,20 sec.maximum 15 mA max.
12-22 AWG
Reset Time Maximum Ripple Voltage
Temperature Range 1 sec.minimum,8 sec.maximum 10%of supply voltage
32°F to 120°F(0°C to 49°C)
Relay Characteristics(relay base only) Start-up Capacitance
Humidity Range 2 coil latching relay 200 pF
10%to 93%RH noncondensing 1 Form C contact
Resistive contact rating:2 A @ 30 VDC Sound Output
Inductive contact rating: Greater than 90 dBA measured in anechoic room
0.3 A @ 110 VDC(with.35 pF or greater), at 10 feet,24 volts. 85 dBA minimum in
0.3 A @ 120 VAC(with.35 pF or greater), UL reverberant room.
1.0 A @ 30 VDC(with.6 pF or greater)
200 Series Junction Box Selection Guide
Single
Model Gang 3.5" Oct. 4" Oct. 4" Sq. 4" Sq.* 50 mm 60 mm 70 mm 75 mm
B501 No Yes No No Yes Yes Yes Yes No
B210LP Yes Yes Yes Yes Yes No No No No
B224RB No Yes Yes Yes No No Yes Yes Yes
B224B1 No Yes Yes Yes No No No Yes Yes
B501BH No No No Yes No No No No No
B501BHT No No No Yes No No No No No
*with 3.0.mud ring
Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations.
Recessed Mounting Kit Product Overview
Drywall or Used with B501,the RMK400 provides a
0 O Standarduspended ceiling simple installation solution in applications that
junction boxes demand a lower profile smoke detector.
Aesthetically pleasing Uses.Kit is suitable for use with 4"octagon,
50mm,and 60mm junction boxes connected
` a v 11 (i to flexible conduit.
Junction boxes are not included in kit.
` ' Note:Not listed for use with MIX-1251(A).
Ordering Information
Model Description Agency Listing
B501 Flangeless Mounting Base UL, ULC, FM,CSFM,MEA
B210LP Flanged Mounting Base UL, ULC, FM,CSFM,MEA
B501BH Sounder Base UL, ULC,CSFM, MEA,SSL
B501BHT Temporal Tone Sounder Base UL
B224RB Relay Base UL, ULC,CSFM, MEA
B224B1 Isolator Base UL, ULC,CSFM, FM,MEA
RA400Z Remote LED Annunciator
Note: For Canadian models add suffix`A".
NOT TO BE USED FOR INSTALLATION PURPOSES.
MIRCOM° Distributed by:
Canada U.S.A.
25 Interchange Way 60 Industrial Parkway, PMB 278
Vaughan,Ontario L4K 5W3 Cheektowaga, New York 14227
Telephone:(905)660-4655 Toll Free:(888)660-4655
Fax:(905)660-4113 Fax Toll Free: (888)660-4113
Web page: http://www.mircom.com Email: mail@mircom.com CAT.5906
CD
6,(9 Rev.4