HomeMy WebLinkAboutA15-0064_Mircom DETECTOR BASES_1437499680.pdf A1. MIRcQM® MOUNTING BASES 200 SERIES Mircom's mounting bases and kits provide a variety The MIX-200 Series detectors can be mounted in of ways to install detectors in any application. either flanged orflangeless bases depending on the junction box selection. • B501 Flangeless Mounting Base B501 BH Sounder Base The 6501 is standard base with no flange. The B501 BH Sounder Base provides a built- in sounder which can be used for evacuation purposes. . ;. I_ A , -- r 1 • • B210LP Flanged Mounting Base B224RB Relay Base The B210LP is a low profile mounting base with a The B224RB Relay Base provides one form C relay flange. contact for control of auxiliary functions such as damper control and elevator recall. • • v 51`rNC B224BI Isolator Base The B224BI Isolator Base allows loops to continue UL (foril 411> to operate under fault conditions and automatically APPROVED restore when the fault is removed. CATALOG NUMBER 5906 NOT TO BE USED FOR INSTALLATION PURPOSES. �1 V Mircom reserves the right to make changes at any time without notice in prices,colours,materials,components,equipment,specifications and models and also to discontinue models. Specifications Base Specifications B224RB/B224B1 Electrical Ratings B501BH/B501BHT Electrical Ratings Diameter Operating Voltage External Supply Voltage 4.0"(102 mm);flangeless 15 to 32 VDC 17 to 32 VDC 6.1"(155 mm);flange Standby Ratings Standby Current Height <500 pA maximum @24 VDC 1.0 mA max. 1.2"(31 mm) Set Time Alarm Current Wire Gauge 4 sec.minimum,20 sec.maximum 15 mA max. 12-22 AWG Reset Time Maximum Ripple Voltage Temperature Range 1 sec.minimum,8 sec.maximum 10%of supply voltage 32°F to 120°F(0°C to 49°C) Relay Characteristics(relay base only) Start-up Capacitance Humidity Range 2 coil latching relay 200 pF 10%to 93%RH noncondensing 1 Form C contact Resistive contact rating:2 A @ 30 VDC Sound Output Inductive contact rating: Greater than 90 dBA measured in anechoic room 0.3 A @ 110 VDC(with.35 pF or greater), at 10 feet,24 volts. 85 dBA minimum in 0.3 A @ 120 VAC(with.35 pF or greater), UL reverberant room. 1.0 A @ 30 VDC(with.6 pF or greater) 200 Series Junction Box Selection Guide Single Model Gang 3.5" Oct. 4" Oct. 4" Sq. 4" Sq.* 50 mm 60 mm 70 mm 75 mm B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes B501BH No No No Yes No No No No No B501BHT No No No Yes No No No No No *with 3.0.mud ring Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Recessed Mounting Kit Product Overview Drywall or Used with B501,the RMK400 provides a 0 O Standarduspended ceiling simple installation solution in applications that junction boxes demand a lower profile smoke detector. Aesthetically pleasing Uses.Kit is suitable for use with 4"octagon, 50mm,and 60mm junction boxes connected ` a v 11 (i to flexible conduit. Junction boxes are not included in kit. ` ' Note:Not listed for use with MIX-1251(A). Ordering Information Model Description Agency Listing B501 Flangeless Mounting Base UL, ULC, FM,CSFM,MEA B210LP Flanged Mounting Base UL, ULC, FM,CSFM,MEA B501BH Sounder Base UL, ULC,CSFM, MEA,SSL B501BHT Temporal Tone Sounder Base UL B224RB Relay Base UL, ULC,CSFM, MEA B224B1 Isolator Base UL, ULC,CSFM, FM,MEA RA400Z Remote LED Annunciator Note: For Canadian models add suffix`A". NOT TO BE USED FOR INSTALLATION PURPOSES. MIRCOM° Distributed by: Canada U.S.A. 25 Interchange Way 60 Industrial Parkway, PMB 278 Vaughan,Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone:(905)660-4655 Toll Free:(888)660-4655 Fax:(905)660-4113 Fax Toll Free: (888)660-4113 Web page: http://www.mircom.com Email: mail@mircom.com CAT.5906 CD 6,(9 Rev.4