Loading...
HomeMy WebLinkAboutA15-0065_FA0.1_1439308320.pdf olti OF.10 „,sz"eil, Z 4. x.74. ,_ ,,, a Building �O��O .eC ,� � 2 ,5 ..„, 6 �.7j ,G •� 3263 . i•e'• •ryency Services ��''• •/r , di , , #'`S”. 4./ AL 07/14/15 V 4111110 l At 0 tt Ln ,— rn ti — rn N I- (n p 1--- 0 U rn 0 a I-1-1 oCC Q J X Q J < CC IL Q Resort and Conference Center _ . O (...) ,_, ,,,, c, . .,,, . , .0,0 W W rn W0 o o C 0 c'') Lai m 41adi.J a Vail , Colorado Ems. ' \ :I.0 o.4 , 4 _ z V Q 161 r 11) 41 GSI FIRE ALARM MODIFICATIONS - ELEVATOR RECALL UPGRADE ,, , ‘ i :C.aROJ4I t1rc‘vt J4O P�O�QQ pQ- 00 e t. l!t Z6 Off,•`p��� QJ ��5 J \�\. Q\, Q, \- Q� <c, GP 5 PQ Q G �0 J)GP �\, , �, N.- JO \-J JSP .� Q-k �. �� pQ- 0 N.-.s•� ��G' 5 c2P P O Q P 0���' GP v5 �O \O�.JQ�' P Q� - per- e2 \ � \P ,s0 4) GQ'O ,issQ s��g\e'P JO �� J`Q g0 g0 �5 G F, O J P ��. � �J��Q�0��0����,��O�pQ�OQ�,`p��P��F. ���� \per �` �` Q` F, F, Q ,\ J p P P P P p �O v �O Q- QS P.)- v-- Q OJQ c, q- e0����F��F� ���P'�PJO\G'\�P,OC F. JP JP�5 JP JP 42 JP JP�5 'S J�JQ-JP 0- ��' 0\'JP JP PGS N. .kl-v- 6N. PGS��- 6PG's�Q-N.—����PG'sPG's,\\�,0-6PG's BLDG. OCCUPANCY: GROUP A-2.1 , B, R-1 SMOKE OR HEAT DETECTOR OTHER THAN 1ST FLOOR ELEVATOR LOBBIES • • • • • • BLDG . USE: BUSINESS / HOTEL SHEET I \ EX HEAT DETECTOR IIN1ST FLOOROR ELEVATOR SHAFT (PET)LOBBY SMOKE DCORRELEVATOR MACHINE ROOM • • • _S • • • • STORIES: BUILDING CONSITS OF A 7 STORY HIGH RISE PLUS FA0.1 FIRE ALARM COVER SHEET AMPERLOW SWITCH • • • • • • • • FA1.1 FIRE ALARM PLANS DUCT MOUNTED SMOKE DETECTOR • • • • BASEMENT MANUAL PULL STATION • • • • w SPRINKLED: FULLY GROUND FAULT • • • L1J OPEN CIRCUIT • • • _ NOTIFICATION APPLIANCE SHORT CIRCUIT • • • CO RELATED CODES: 2012 INTERNATIONAL BUILDING CODE (IBC) LOW BATTERY • • • ( ) AC POWER FAILURE • • • LI] 2012 INTERNATIONAL FIRE CODE (IFC) TELEPHONE LINE FAULT • • • > 2011 NATIONAL ELECTRIC CODENFPA 70) REMOTE POWER SUPPLY TROUBLE CONDITION • • • U ( SILENCE BUTTON AT FACP • • • • VAIL AMENDMENTS RESET BUTTON AT FACP • • CARBON MONOXIDE DETECTOR • • • fY Q J Q SEQUE\ CE OF OPEATIO \ : fY GE\ EAL \ OTES THE SEQUENCE OF OPERATION WILL NOT CHANGE FROMA A THAT WHICH IS CURRENTLY ON FILE WITH THE CITY. DRAWING TITLE I. Installation shall conform to all requirements of applicable electrical codes. WHEN AN AUTOMATIC INITIATING DEVICE IS ACTIVATED IT WILL II. Wiring methods and materials shall conform with all applicable sections of NEC Article 760. INITIATE ACTIVATION OF THE SPEAKERS AND STROBES ON THE FIRE FLOOR AND THE FLOOR DIRECTLY ABOVE AND III. 120VAC 60 Hz input power for fire alarm controls shall be a dedicated, locking, properly labeled, BELOW THE FIRE FLOOR. IT WILL ALSO RELEASE MAGNETIC FRE E A LA U LEGE\ D source DOOR HOLDERS AND CLOSE DAMPERS ON THESE FLOORS. IV. All wiring, including shields, must be dry and free of shorts and grounds. SMOKE DETECTORS SHALL ANNUNCIATE ON MAIN FLOOR SYMBOL DESCRIPTION QUANTITY — NEW V. 120VAC is not permitted in same conduit with low voltage wiring. ANNUNCIATOR AS ALARM ON FIRE FLOOR. ACTUAL ALPHA HEAT DETECTOR, SIGA2—HRS WITH SIGA—SB4 5 VI. Do not apply power except in the presence of a factory—trained technical representative. NUMERIC ADDRESS OF DEVICE SHALL BE DISPLAYED AT BASE FACP. 12 ® CONTROL RELAY MODULE, SIGA—CR 8 ELEVATOR LOBBY AUTOMATIC INITIATING DEVICES OTHER THAN I=1 SINGLE INPUT MODULE, SIGA—CT1 3 IN PRIMARY RECALL FLOOR LOBBY SHALL RECALL ELEVATOR I— TO PRIMARY RECALL FLOOR. EXISTING FIRE ALARM CONTROL PANEL C I C U IT WRI G : z ELEVATOR LOBBY AUTOMATIC INITIATING DEVICE IN PRIMARY LLJ W END OF LINE RESISTOR RECALL FLOOR LOBBY SHALL RECALL ELEVATOR TO U 16/2 INITIATION CIRCUIT ALTERNATE RECALL FLOOR. CV SMA — STAND—BY CURRENT (IN MILLIAMPS) 14/2 STROBE CIRCUIT ill ALMA — ALARM CURRENT (IN MILLIAMPS) 16/2 SPEAKER CIRCUIT AUTOMATIC INITIATING DEVICES IN ELEVATOR SHAFT OR (D U MA — MILLIAMPS MACHINE ROOM WILL SEND A NOTIFICATION SIGNAL TO THE Z Z QTY — QUANTITY 16/2 = 1 PAIR #16AWG SOLID COPPER ELEVATOR CAB. 1-1-1(E) — EXISTING 14/2 = 1 PAIR #14AWG SOLID COPPER Q N SLC IDC WIRING — 1LARGER WIRES MAY BE USED FOR VOLTAGE DROP 6/2 THERMAL DETECTION IN ELEVATOR SHAFT OR MACHINE ROOM J 12 L / WILL ACTIVATE ELEVATOR SHUNT TRIP. — L J �--N NAC WIRING — 14/2 SLC WIRING IS CLASS B/ STYLE 4 m Z A RISER SPEAKER WIRING — 16/2 NAC WIRING IS CLASS B/ STYLE Y I O B RISER SPEAKER WIRING — 16/2 I— (..) \ ICET IV CETIFICATIO \ ~O o WI \ G PRACTICES : THE ALAfV SYSTEVS - Q CABLES USED WILL BE TWO CONDUCTOR, SOLID COPPER, 101940 Q I- O FPLP RED AND BLACK JACKETED. RED OR LIGHTER . r U COLOR FOR POSITIVE AND BLACK OR DARKER COLOR FOR ____,,,(-„,7,2,., — --- — NEGATIVE. SIZE OF CONDUCTORS SHALL BE AS M I C H EAE SCA\ GA J O J DESIGNATED IN CIRCUIT WIRING SCHEDULE ABOVE. SCOPE OF W0 '< : PROPRIETARY DOCUMENT PROJECT TITLE ADDITION OF NEW INITIATING DEVICES WITHIN AN EXISTING DATE: IN THE NATURE OF TRADE SECRETS, THIS 07102115 ELEVATOR MACHINE ROOM TO UPGRADE AN EXISTING ELEVATOR DRAWING AND THE DESIGNS THEREON ARE RECALL SYSTEM. SCALE: THE PROPRIETARY AND CONFIDENTIAL AS SHOWN NEW INITIATING DEVICES SHALL BE CONNECTED TO EXISTING INFORMATION OF ALARMSPECIALISTS, INC. DRAWN BY: THESE DRAWINGS SHALL NOT BE JBS LOCAL DATA CIRCUIT DERIVED AT EXISTING NODE 2 FACP. DUPLICATED, USED, OR DISCLOSED TO CHECKED BY: OTHERS, EXCEPT AS OTHERWISE AHM NO NEW NOTIFICATION APPLIANCES SHALL BE ADDED UNDER AUTHORIZED BY CONTRACT, WITHOUT CAD FILE: THIS CONTRACT. WRITTEN PERMISSION OF DRAWING SHEET No. ALL EQUIPMENT AND DEVICES WILL BE INSTALLED IN ALARMSPECIALISTS, INC. ACCORDANCE WITH NFPA 72. MATSUO ENGINEERING, LLC CONSULTING ELECTRICAL ENGINEERS 760 DEVINNEY COURT F1O. I GOLDEN,CO 80401 (303)231-8890 FAX(303)672-8290 15.09.12