HomeMy WebLinkAboutA15-0065_Input Modules_1438119480.pdf EST Catalog►Intelligent Input-Output T-ST Life Safety & Communications Alan .... .-- Input Modules SIGA-CT1 , SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 i„:11, �, i Signature Series OverviewU10Motherboard The Signature Series intelligent analog-addressable system from 1 6-32 9 9 g- y / � Self-tapping Edwards Security is an entire family of multi-sensor detectors and screws mounting bases, multiple-function input and output modules, E _--0 g-in network and non-network control panels, and user-friendly main- 0,Captive tenance ain- tenance and service tools.Analog information from equipment PluModu elf) s�etws connected to Signature devices is gathered and converted into __ �__� digital signals.An onboard microprocessor in each Signature de- _ vice measures and analyzes the signal and decides whether or not \ fi Flat washers to input an alarm.The microprocessor in each Signature device provides four additional benefits-Self-diagnostics and History _—cabinet or electrical enclosure Log,Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Electronic Addressing-The loop controller electronically ad- Self-diagnostics and History Log-Each Signature Series dresses each module, saving valuable time during system corn- device constantly runs self-checks to provide important mainte- missioning. Setting complicated switches or dials is not required. nance information.The results of the self-check are automatically Each module has its own unique serial number stored in its updated and permanently stored in its non-volatile memory.This on-board memory.The loop controller identifies each device on information is accessible for review any time at the control panel, the loop and assigns a"soft"address to each serial number. If PC,or using the SIGA-PRO Signature Program/Service Tool. desired,the modules can be addressed using the SIGA-PRO Automatic Device Mapping-The Signature Data Control- Signature Program/Service Tool. ler(SDC)learns where each device's serial number address is Edwards recommends that this module be installed according to installed relative to other devices on the circuit.The SDC keeps a latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits be- Application tween each device can be examined. Layout or"as-built"drawing information showing branch wiring(T-taps), device types and their The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- address are stored on disk for printing hard copy. termined by their sub-type code or"Personality Code".The code is selected by the installer depending upon the desired application Installation and is downloaded from the loop controller. SIGA-CT1,SIGA-CT1 HT and SIGA-CT2: modules mount to One personality code can be assigned to the SIGA-CT1.Two per- North American 21 inch(64 mm)deep 1-gang boxes and 11/2 inch sonality codes can be assigned to the SIGA-CT2/MCT2. Codes (38 mm)deep 4 inch square boxes with 1-gang covers and SIGA 1, 2,3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For MP mounting plates.The terminals are suited for#12 to#18 AWG example, personality code 1 can be assigned to the first address (2.5 mm2 to 0.75 mm2)wire size. (circuit A)and code 4 can be assigned to the second address (circuit B). 411111) NORMALLY-OPEN ALARM -LATCHING(Personality Code 1) Compatible electrical box -Assign to one or both circuits. Configures either circuit A or B or �� both for Class B normally open dry contact initiating devices such 11111111111(1111111"t I as Pull Stations, Heat Detectors, etc.An ALARM signal is sent to 1�I the loop controller when the input contact is closed.The alarm + , condition is latched at the module. 1Wall plate,white .���1\ IC,-\\ (1-gang) NORMALLY-OPEN ALARM -DELAYED LATCHING (Person- ality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches.An ALARM signal mm ', is sent to the loop controller when the input contact is closed for �!�� Q approximately 16 seconds.The alarm condition is latched at the module. Status LEDs NORMALLY-OPEN ACTIVE- NON-LATCHING (Personality Code 3)-Assign to one or both circuits. Configures either circuit LED viewing ports • A or B or both for Class B normally-open dry contact monitoring o input such as from Fans, Dampers, Doors, etc.An ACTIVE signal • ° is sent to the loop controller when the input contact is closed.The active condition is not latched at the module. SIGA-MCT2: mount the UIO motherboard inside a suitable NORMALLY-OPEN ACTIVE- LATCHING (Personality Code Edwards enclosure with screws and washers provided. Plug the 4)-Assign to one or both circuits. Configures either circuit A or SIGA-MCT2 into any available position on the motherboard and B or both for Class B normally open dry contact monitoring input secure the module to the motherboard with the captive screws. such as from Supervisory and Tamper Switches.An ACTIVE signal Wiring connections are made to the terminals on the motherboard is sent to the loop controller when the input contact is closed.The (see wiring diagram). UIO motherboard terminals are suited for#12 active condition is latched at the module. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Page 2 of 4 DATA S H E E N 85001-0241 Not to be used for installation purposes. Issue 8 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16(1.0mm2), and#14AWG(1.50mm2), and#12 AWG(2.50mm2)wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm2) #16 AWG(1.00 mm2) 4,000 ft(1,219 m) #14 AWG(1.50 mm2) #12 AWG(1.50 mm2) Typical N.O.Initiating Device Typical N.O.Initiating Device J• INPUT 1 INPUT 2 HHA HH iniii AAA Q4 Style B(Class B) hum .:=:. TB2 11(11171.7 TB2 I I 111 ll_ 8 7 UL/ULC Listed S le B Class B r • 471x1 EOL UL/ULC Listed ( ) e 5 s UL/ULC Listed 47Kg EOL 1., ® 1 .7 • • l 47KII EOL Red LED Green LED (Alarm/Active) 0 (Normal) Red LED Green LED 4 342 1 (Alarm/Active) 4 3 2 1 I (Normal) TB1I(11) TB1I(�)6I. ( DATA IN(+) ► (+) DATA OUT 1 j(DATA IN(+) ' DATA OUT(+) l DATA IN(-) 0,..DATA OUT(-)/ l DATA IN(-) DATA OUT(-) To Next Device From Signature Controller To Next Device From Signature Controller or Previous Device or Previous Device Q 3 SIGA-CT1, SIGA-CT1 HT SIGA-CT2 1 1 1 Typical NO Initiating Device I i NOTES UL/ULC Listed +I pin + HD Input2 UL/ULC Listed 47KW EOL47KW EOL A Maximum 25 Ohm resistance per wire. A Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). •■' e e e ARefer to Signature controller installation sheet for wiring specifications. /w\Maximum 10 Vdc CO 350 pA MCT2 AThe SIGA-U106R and the SIGA-UIO2R do not come with TB14. 2 s 4A UIOIRI series motherboard 6 All wiring is supervised and power-limited. + 4 Data In Li Q 7 These modules will not support 2-wire smoke detectors. : 4 ,RI 1 �isSignature I 2 . �l TB14 No connections required for Data ■ i Uilo,MCT2Circuit+ Other modules may require DataOut+ MCT2connectionsWarnings & Cautions IIi:iIP Green LED(Normal} This module will not operate without electrical power.As fires fre- RedLED(Active) quently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. NegconneciMCTz jumper settings Compatibility SIGA-MCT2 The Signature Series modules are compatible only with EST's Signature Loop Controller. Page 3 of 4 DATA S H t t I 85001-0241 Not to be used for installation purposes. Issue 8 Specifications (DWARDS Catalog Number SIGA-CT1HT I SIGA-CT1 SIGA-CT2 I SIGA-MCT2 United Technologies Description Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types Contact us... (personality codes)are available (personality codes)are available Email: edwards.fire@fs.utc.com Address Requirements Uses One Module Address Uses Two Module Addresses Web: www.est-fire.com Operating Current Standby=250pA; Standby=396pA; EST is an EDWARDS brand. Activated=400pA Activated=680pA 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Mebane,NC 27302 Construction High Impact Engineering Polymer In Canada,contact Chubb Edwards... Mounting North American 21/2 inch(64 mm)deep one-gang box- UIO2R/6R/6 Email: inquiries@chubbedwards.com es and 11/2 inch (38 mm)deep 4 inch square boxes Motherboard Web: www.chubbedwards.com with one-gang covers and SIGA-MP mounting plates ©2013 UTC Fire&Security Americas Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) Corporation,Inc.All rights reserved. (0°C to 70°C) Specifications subject to change Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH without notice.Edwards is part of UTC Climate,Controls&Security,a unit of LED Operation On-board Green LED-Flashes when polled;On-board Red LED- United Technologies Corporation. Flashes when in alarm/active. Both LEDs-Glow steady when in alarm(stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-CT1 Single Input Module— UL/ULC Listed 0.4(0.15) SIGA-CT1HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module— UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(UIO)Module — UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box-White, 1-gang 1.0(0.6) SIGA U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions SIGA U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) —Six Module Positions SIGA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet— Red,supports Signature Module 7,0(3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) a Page4of4 DATA SHEE 85001-0241 to Not to be used for installation purposes. Issue 8