Loading...
HomeMy WebLinkAboutA15-0066_Cut sheets_1438273080.pdf GE Security Standard features Overview • Expandable to 192 fully programmable hardwire The NetworX NX-8E is a full-featured security system and/or wireless zones that uses advanced technology for burglary,fire and • 240 user codes environmental detection. The NX-8E is a flexible security system that is both easy to install and simple to use. • Up to 192 addressable devices can be used With eight partitions and up to 192 zones,the NX-8E can • 512-event history log that provides date,time, event handle your most demanding commercial and and user number residential security needs. • Up to 8 true partitions with separate account codes, Outstanding features entry/exit delays, and feature selections for each partition The NX-8E panel comes standard with eight hardwire • Maximum of 32 keypads with up to 8 per partition zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an • Wireless technology with up to 192 supervised zones alarm or other system event.The modular design allows • 2-wire or 4-wire smoke detector compability for complete integration of multiple systems within one • Fire alarm verification for greater false alarm immunity enclosure. Adding more zones or expanding capability is fast and easy. • Dynamic battery test • Standard RS-232 on-board interface Convenient and flexible Conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with the DL-900 software for Windows. NetworX Control Panel NX- 8E 0 A!! Zones SEG . 'Et PietworX • 0 GE Security NetworX Control Panel NX-8E Available Keypad Styles Specifications • Operating Power- 16.5V AC 40VA • Auxiliary w/40VA or 50VA transformer- 2 Amp • Auxiliary w/NX-320E power supply - 3 Amps* IMIP Loop resistance • For standard loop - 30052 Maximum • For 2-wire smokes - 30Q Maximum LED with LCD with Operating temperature Removable Door Removable Door • 32°to 120°F Dimensions • 6.40 inches wide • 4.0 inches high — — — - — • 1.10 inches deep Shipping weight .vi • 9 pounds Fixed Display with LED with *When using the NX-320E(w/5OVA transformer)rated at 2 Amps and NX-8E Removable Door Removable Door (w/40VA or 5OVA transformer)rated at 1 Amp,the combined available power is 3 Amps. Customer Service and Technical Support: 1-888-GE Security (437-3287) 12345 SW Leveton Drive Tualatin,OR 97062 Phone:503-692-4052 USA&Canada:800-547-2556 www.gesecurity.com Si 0 imagination at work ©2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466-2134-KA-0105 [;E NetworX NX-148E-RF touchpad Security The NX-148E-RF is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to-read, customizable display. It is compatible with all NetworX control panels(except commercial fire). The NX-148E-RF offers the are also five pre-programmed touch Features convenience of having an integrated keys that allow the most common wireless receiver built into the keypad functions to be performed with ease. • Integrated 48-zone wireless along with standard hardwire features. All keys on the NX-148E-RF are backlit receiver A removable door allows the user to ensure error-free operation—even • Optimize wireless reception by to swing the door down or simply in a dark room. having the keypad/receiver in the take it off for use.The NX-148E-RF The NX-148E-RF is cost-effective best location emergency keys are highlighted on and easy to install. Designed for • LCD, easy-to-read programmable the keypad and can be programmed functionality and compatibility,the NX- display to contact and send complete 148E-RF is the right keypad to fit any information to a responding police,fire application. • Traditional design to go with any or EMS unit with just one touch.There decor • Compatible with all NetworX series control panels (except commercial fire) • Easy to install, program and N etwo rX N X- 148 E- R F maintain wireless LCD display keypad 5ecur~ Armed Ready Fire Power s o — o Specifications Americas Electrical Ordering information 503-885-5700 •Current:75 to 110 mA nominal NX-148E-RF NetworX 48-zone LCD display 888-GE-SECURITY Environmental keypad with door and integrated (437 32871 •Operating temperature:32 to 120°F(0 to 49°C) wireless receiver faxback 800-483-2495 Physical info@gesecurity.com •Dimensions(HxWxD):5.30 x 6.20 x 1.30 in.(135 x www.gesecurity.com 157 x 33 mm) •Construction:ABS plastic Asia •Color:White tel 852-2907-8108 fax 852-2142-5063 Australia tel 61-3-9259-4700 fax 61-3-9259-4799 Europe tel 32-2-725-11-20 fax 32-2-721-86-13 Latin America tel 305-593-4301 fax 305-593-4300 ©2006 GE Security. As a company of innovation,GE Security reserves the right to change product specifications without notice.For the latest product specifications,visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322 DS nx-148e-rf 466-70.13 Si GE I nterl ogi x Product Information www.C Inteiogix.com PinPoint Addressable Fbint ID Systems Overvi ew The RnFbi nt addressable solutions bring together NetwcrX NX-8E fuuxionditywith the reliability of GE Interlogix sensors. 7, 4110. Supporting up to 192 devices on a single two-wire loop up to two niles,the RnFbint pant IDsolution can be installed fast in new construction or retrofit applications. 4 L Components 71r NetworX NX-8E I I/ Part#NX-8E l I I I IIIR nPoi nt Interface Card Part#NX-2192E AP SeriesEl Standard Features Motion Sensor o Si ngl e two-w i re loop up to two miles means fast and easy Part#AP750-ID installation for new construction or retrofit applications o Addressable sensors indicates exact l ocati on of alarm or trouble event ShatterPro® o Supports up to 192 devices • Gassbreo Advanced digital communication from the sensors to Part#5845-1D the panel o GE Interlogix—a name you know and trust o Supports 3 a ass B loops CISingle Input Device Part#S1-1D ZI4Input 4 Output Device Part#4144ID PinPoint Addressable Fbi rit ID Systerrs AP750-I D Addressable PI R Description Specifi cati ons An addressable RRfor use with the NX 2192ERrpant ID Bus Housing Material Rare retardant ABS Interface Operating voltage 8 to 27V(as supplied by N)F2192E) Current draw 250µA typical avg.3mAwith LED momantarily on Features Transmit condition Alam,tamper Detection range 50 ft(15.2m) AcIaptiveSncglefooessing-3Dsignal processing with gliding Mounting height 6 to 10 ft(1.8 to 3m) focus nirror optics analyzes sim,speed,shape and adaptive Number of curtains 7 alarm threshold. Operating temperature 32°to 131°F(0°to 55°C) Friel ati ve humidity 10%to 90%nonoor densi ng Rovi des far separate curtain average patterns with 50' Maxi mum I i ne length 10,000 ft(31mi) (15.2 m)range. Di mensi ons Flatcomer wall or coer mounting height up to 10'(3m). D Width 2. (74mm) Depth 2.2(56mm) Ships with two plastic inserts,each covering half the coverage Height 5.1'(129mm) pattern for more flexible mounting options(center curtain Listings (1639,Rx always alive). Coverage Patterns 50' 15.2m �\ I I ��-� II I I 3.0m I 45° Left ' 1 7 44m 45° F4 ght 5845-I D Addressable Shatterpro®GI assbreak Description Spec ifi cat ons An addressable ShatterRo®ll gl assbreak for use with the Housing material Rare retardant ABS NX-2192E RnRbi nt ID as Interface. Operati ng voltage 8 to 27V(as supplied by NX 2192) Current draw 250µAtypical avg.3m4 with LID=mentally on Features Microphone 0mi-directional eledret Operating temperature 14°to 120°F(10°to 50°C) ShatterR-o's Pattern Fieoognition Technology'"for superior Relative humidity 10%to 90%nonoondensi ng detection and fa se alarm irrrrunity. Maxi mum I i ne length 10,000 ft(3lom) Roteds all glass types up to a standard thickness of 1/4" Di rrrensi ons (6.4 m)including plate,wired,tempered and land nated glass. Width 3.13 (80rrm) mm) Depth 1.7'(4311111) Senses through light blinds and unlined drapes.Suitable for use Height 4.2(108r m n) in occupied areas cn the perimeter loop. Listings MC i v Wall mount 0'(6max ) m 20'(6m)/ � max. Ceiling mount PinPoint Addressable Fbi nt ID Systems SI-ID Single Input Device Description Specifications Anadci-essablesingle input interface toconnect asingle I-busing material Hare retardant ABS non-addressable device to the NX-2l92EPnRjuit ID Cperati ng voltage 8 to 27V(as supplied by NX-2192E) bus interface. Signaling voltage 4 to 9V Current draw 250µA operating temperature 32°to 131°F(0°to 55°D Features Fel ati ve humidity 10%to 90%noncondensi ng Maxi mum I i ne length 10,000 ft(3km) Supports a single non-addressable device. Dimensions Width 3.3(84rrm) Uilixs advanced digital data corrrrunications protocol that Depth 13(331rrn) ensures the integrity of the data corrrruni cati on. Height 2.8'(71rrm) Li stings LL 365,U_609,U_985, U_1023,U_1610,FCC Input Loop Resistance Reported to panel To single (47k ECL included) non-addressable From PinPoint device,such as a loop O magnetic contact >1M— Cpen 47l % Single B1 J 941 % Double B1 >20❑ Short 4140-ID Four Input Four Output Device Description Specifi cati ons An addrescable 4 input and 4 unsupervised output interface Housing material Flame retardant ABS that al Iays you to conned up to 4 nonradd-essable devices Cperati ng voltage 12 to 30VDC to the NX 2192E RnRbi nt ID Bus Interface. Signal i ng voltage 4 to 9V Current draw 100µA(bus loading) Features Output current 500m4 rradrrum eadi Cperati ng temperature 32°to 131°F(0°to 55°C) Supports four inputs andfair unsupervised outputs FelativeHumidity 10%to 90%nonoondensing (horns,bells,sirens,etc.). Maxi mum line length 10,000 ft(3km) Uilims advanced digital data com7unications protocol that Di idth ns ensures the integrity of the data cor .nication. D pth 6.8'(173rrm) m� Depth 2.0'(51n-m) Height 4.8'(122rrm) Listings LL 365,LL 609,LL 985,LL 1023,111610,FCC To unsupervised Addressable 1 outputs,such as Inputs 0 0 0 horns and sirens Input Loop Resistance Reported to panel (47k ECL i ncl uded) >1M Cpen o 0 oJ 47k±5% Single ECL 9.4k % Double B1 >20H Short PinPoint Addressable Fbirttt IDSystems NX2192E Description Specifi cati ons Rint ID as Interface Card. Current Draw 170 m4 standby maximum C perati ng temperature 32°to 122°F(0°to 50°G) Shipping Weight 0.5 lb. Features D mensi ons Width 2'(51rm) Attaches to the NX-8Eccntrd pard. Depth 1.25(32nm) as interface that supports up to 192 addraable devices on Height g(229r m) a two-rile loop. Supports three dasc B loops. Ordering Information Model Description Listing Approvals NX-8E NetwcrXNX8Econtrd paid — ll NX-2192E RnFbi nt interface card — LL AP750-ID Ge interlogx RR White UL 5845-ID Cainterlogixgassbreak White RCC SI ID Engle input device White LL 414GID 4 input 4 output device White 11 CInterlogix www.CEIrrteriagxczm 12345SWLevetcnDive 22ti6SsaaxlStreet Nath Tualatin,CR97062 North St.Pat/,MN 55109 Foie:503-692-4052 Rr ie:651-777-2693 54&Canada: LISA&Canada:800-777-5484 Technical Service:800-648-7424 Technical Service:893-777-2624 Fadzadc 800-483-2455 ©2003CEInterlojxarnke!in a Can is atraderrerkcfCfInterlogxPlltraderrni¢are properties cftheir oars. M-4301-xO004(0103 SYSTEM �$ SENSOR Smoke Detectors with Sounder and Relay Option 7 System Sensor ir sounder and relay smoke detectors apply the guiding principles of installation ease, 3 intelligence,and instant inspection in a series of TM specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple •85 dB sounder with its installer-friendly base and plug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample space for pre-wiring the device.To Isolated thermal sensor complete the installation,the i3 detector plugs into its base with a • simple Stop-Drop'N Lock action. •Plug-in design(base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i3 detectors are equipped with both drift compensation and •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock"attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an i3 Ready' panel,2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift compensation and smoothing algorithms the SENS-RDR displays the reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the i3 line offers an isolated thermal model,which (13 ® sO MEA MSFMETA initiates a local alarm when smoke is detected,and a general alarm LISTED APPROVED approved approved cC r. us when the thermal sensor is activated. i�11 3015195 7272-1653:164 372-02-E 2133 3180932 �j�Smoke Detector Specifications Electrical Specifications LED Modes Operating Voltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5 V to 35 V Power up Blink every Blink every 10 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum Ripple Voltage 30%of applied voltage(peak to peak) indication Standby Current 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 pA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every 5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4VVTAB,4WTR 6:35 mA Power-Up Sequence for LED Indication 4WTAR-B,4WITAR-B:50 mA **Direct Power(Non-Reverse Polarity):130 Condition Duration mA limited by panel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current. Architect/Engineer Specifications Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal Physical Specifications equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2VVTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated Operating Temperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating Humidity 0 to 95%RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall be a plug-in type.The detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift Input Terminals 14-22 AWG compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4WITAR-B only) shall provide a loop testing capability to verify the circuit without testing each Mounting 311/z inch octagonal back box,4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single gang back box,4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a plaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--. SYSTEM 02009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensor.com for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0348-004.6/09•#2170 SYSTEM SENSORI, 4 • TM i4 Series . Combination CO/Photoelectric • 0 Smoke Detector • Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than • Single device for CO and smoke detection that uses less wiring two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 Interface Module. easily replaced at end-of-life, resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The • base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station. Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms, reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. ,T LISTED S268 7272-1653:0203 i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal: 12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200mA Maximum Start-up Capacitance: .10 pF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4",3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series 11 Interface Module • The i4 Interface Module connects up to 12 detectors to a wide range of control panels using only 2 to 3 zones. • Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones:a smoke zone,a CO zone and an control panels optional trouble zone. Detectors sound Temp 3 for smoke and Temp • Sends distinct smoke and CO signals from i4 detectors to the panel 4 for CO events.The i4 module can be used to alarm all sounders in • LED indication shows when a detector on the loop requires compatible detectors for smoke and CO events.When one detector cleaning or maintenance(2-wire detectors only) detects smoke or CO and goes into alarm,all connected detectors Initiates the EZ Walk loop test(2-wire detectors only) alarm,offering the highest level of warning to the homeowner. • Installation ease:The i4 Series Interface Module mounts to a 411/16-inch square back box for quick and easy installation.Terminal blocks with durable SEMS screws ensure a reliable connection. It also has pre-drilled holes for easy mounting inside a metal enclosure Intelligence:The i4 Interface Module allows i4 and compatible i3 smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings ® N LISTED 17272-1653:0203 i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i4 Series and i3 Series detectors with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire), 10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:62mA(max.),45mA(12V In),27mA(24V In); 4-Wire:52mA'(max.),36mA'(12V In),20mA'(24V In) Alarm Current2: 2-Wire: 174mA(max.), 116mA(12V In),60mA(24V In); 4-Wire:75mA'(max.),54mA'(12V In),32mA'(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA I@ 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04 Depth: 1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20—70°C(-4—158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 5 sec. Off On Off Alarm CO: Blink 5 sec. Off Off On Alarm Smoke&CO: Blink 5 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 5 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 5 sec. Blink 5 sec Off Off Smoke Maintenance(2-wire only): Blink 5 sec. Off Blink 5 sec Off Smoke Freeze Trouble(P 2WTA-B only): Blink 5 sec. Off Blink 10 sec Off CO Trouble: Blink 5 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) *Th_ SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SEw SO� for current product information,including the latest version of this data sheet. ,vJ www.systemsensor.com SCDS00201•03/13